메뉴 건너뛰기




Volumn , Issue , 2008, Pages 4681-4684

Preclinical dual-energy x-ray computed tomography through differential filtration

Author keywords

[No Author keywords available]

Indexed keywords

BEAM-HARDENING; DUAL-ENERGY; DUAL-ENERGY X-RAY; NEW APPROACHES; RECONSTRUCTED IMAGE; SINGLE TUBES; X-RAY BEAM FILTRATION; X-RAY TUBE VOLTAGES;

EID: 67649196372     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774467     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 1
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in x- ray computerized tomography
    • September
    • R.E. Alvarez and A. Macovski, "Energy-selective reconstructions in x- ray computerized tomography", Phys. Med. Biol, vol.21, no. 5, pp. 733-744, September 1976.
    • (1976) Phys. Med. Biol , vol.21 , Issue.5 , pp. 733-744
    • Alvarez, R.E.1    Macovski, A.2
  • 2
    • 0022407220 scopus 로고
    • A beam-hardening correction using dual-energy computed tomography
    • A. Coleman and M. Sinclair, "A beam-hardening correction using dual energy computed tomography", Phys. Med. Biol., vol.30, no. 11. pp. 1251-1256, November 1985. (Pubitemid 16234027)
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.11 , pp. 1251-1256
    • Coleman, A.J.1    Sinclair, M.2
  • 5
    • 67649163849 scopus 로고    scopus 로고
    • http://physics.nist.gov/PhysRefData/Xcom/Text/XCOM.html.
  • 6
    • 33750549467 scopus 로고    scopus 로고
    • On two-parameter models of photon cross sections: application to dual-energy CT imaging
    • November
    • J.F. Williamson, S. Li, S. Devic, BR. Whiting, and FA. Lerma, "On two-parameter models of photon cross sections: application to dual-energy CT imaging", Med. Phys.,\o\. 33, no. 11, pp. 4115-4119, November 2006.
    • (2006) Med. Phys. , vol.33 , Issue.11 , pp. 4115-4119
    • Williamson, J.F.1    Li, S.2    Devic, S.3    Whiting, B.R.4    Lerma, F.A.5
  • 7
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • DOI 10.1118/1.595715
    • R.L. Siddon, "Fast calculation of the exact radiological path for a three-dimensions CT array", Med. Phys., vol.12, no. 2, pp. 252-255, March 1985. (Pubitemid 15089015)
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 8
    • 0026703255 scopus 로고
    • Signal and noise in modulation transfer function determinations using the slit, wire, and edge techniques
    • July
    • I.A. Cunningham and B.K. Reid, "Signal and noise in modulation transfer function determinations using the slit, wire, and edge techniques", Med. Phys., vol.19, no. 4, pp. 1037-1044, July 1992.
    • (1992) Med. Phys., vol. , vol.19 , Issue.4 , pp. 1037-1044
    • Cunningham, I.A.1    Reid, B.K.2
  • 9
    • 0242409499 scopus 로고    scopus 로고
    • AMIDE: a free software tool for multimodality medical image analysis
    • July
    • A.M. Loening and S.S. Gambhir, "AMIDE: a free software tool for multimodality medical image analysis", Molecular Imaging, vol.2, no. 3, pp. 131-137, July 2003.
    • (2003) Molecular Imaging , vol.2 , Issue.3 , pp. 131-137
    • Loening, A.M.1    Gambhir, S.S.2
  • 10
    • 33748033063 scopus 로고    scopus 로고
    • Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging
    • P.E. Kinahan, A.M. Alesio, and J.A. Fessler, "Dual energy CT attenuation correction methods for quantitative assessment to cancer therapy with PET/CT imaging", Technol. Cancer Res. Treat., vol.5, no. 4, pp. 319-327, August 2006. (Pubitemid 44300247)
    • (2006) Technology in Cancer Research and Treatment , vol.5 , Issue.4 , pp. 319-327
    • Kinahan, P.E.1    Alessio, A.M.2    Fessler, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.