메뉴 건너뛰기




Volumn 2, Issue 1-2, 2000, Pages 62-70

High resolution X-ray computed tomography: An emerging tool for small animal cancer research

Author keywords

Animal model; MicroCT; Microtomography; X ray

Indexed keywords

BARIUM; CONTRAST MEDIUM; IODINE; IOHEXOL;

EID: 0034088968     PISSN: 15228002     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.neo.7900069     Document Type: Review
Times cited : (478)

References (75)
  • 1
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography): 1. Description of system
    • Hounsfield GN (1973). Computerized transverse axial scanning (tomography): 1. Description of system. Br J Radiol 46, 1016-1022.
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 2
    • 0015789441 scopus 로고
    • Reconstruction of densities from their projections with applications in radiological physics
    • Cromack AM (1973). Reconstruction of densities from their projections with applications in radiological physics. Phys Med Biol 18, 195-207.
    • (1973) Phys Med Biol , vol.18 , pp. 195-207
    • Cromack, A.M.1
  • 3
    • 33746803555 scopus 로고
    • Image formation by induced local interactions - Examples employing nuclear magnetic resonance
    • Lauterbur PC (1973). Image formation by induced local interactions - examples employing nuclear magnetic resonance. Nature 242, 190-191.
    • (1973) Nature , vol.242 , pp. 190-191
    • Lauterbur, P.C.1
  • 4
    • 0016441373 scopus 로고
    • A positronemission transaxial tomography for nuclear imaging (PETT)
    • Ter-Pogossian MM, Phelps ME, and Mullani NA (1975). A positronemission transaxial tomography for nuclear imaging (PETT). Radiology 114, 89-98.
    • (1975) Radiology , vol.114 , pp. 89-98
    • Ter-Pogossian, M.M.1    Phelps, M.E.2    Mullani, N.A.3
  • 6
    • 0001305395 scopus 로고
    • Nuclear magnetic resonance imaging at microscopic resolution
    • Johnson GA, Thompson MB, Gewalt SL, and Hayes CE (1986). Nuclear magnetic resonance imaging at microscopic resolution. J Magn Reson, 68, 129-137.
    • (1986) J Magn Reson , vol.68 , pp. 129-137
    • Johnson, G.A.1    Thompson, M.B.2    Gewalt, S.L.3    Hayes, C.E.4
  • 7
    • 0001212368 scopus 로고
    • High-resolution imaging: The NMR microscope
    • Eccles CD, and Callaghan PT (1986). High-resolution imaging: the NMR microscope. J Magn Reson 68, 393-398.
    • (1986) J Magn Reson , vol.68 , pp. 393-398
    • Eccles, C.D.1    Callaghan, P.T.2
  • 13
    • 0018877478 scopus 로고
    • High-resolution computed tomography of the normal rat nephrogram
    • Kujoory MA, Hillman BJ, and Barrett H (1980). High-resolution computed tomography of the normal rat nephrogram. Invest Radiol 15, 148-154.
    • (1980) Invest Radiol , vol.15 , pp. 148-154
    • Kujoory, M.A.1    Hillman, B.J.2    Barrett, H.3
  • 17
    • 0000466398 scopus 로고
    • Observational strategies for three-dimensional synchrotron microtomography
    • Flannery BP, and Roberge WG (1987). Observational strategies for three-dimensional synchrotron microtomography. J Appl Phys 62, 4668-4674.
    • (1987) J Appl Phys , vol.62 , pp. 4668-4674
    • Flannery, B.P.1    Roberge, W.G.2
  • 18
    • 0024274002 scopus 로고
    • Examination of subchondral bone architecture in experimental osteoarthritis by microscopic computed axial tomography
    • Leyton MW, Goldstein SA, Goulet RW, Feldkamp LA, Kubinski DJ, and Bole GG (1988). Examination of subchondral bone architecture in experimental osteoarthritis by microscopic computed axial tomography. Arthritis Rheum 31, 1400-1405.
    • (1988) Arthritis Rheum , vol.31 , pp. 1400-1405
    • Leyton, M.W.1    Goldstein, S.A.2    Goulet, R.W.3    Feldkamp, L.A.4    Kubinski, D.J.5    Bole, G.G.6
  • 19
    • 0024589979 scopus 로고
    • The direct examination of three-dimensional bone architecture in vitro by computed tomography
    • Feldkamp LA, Goldstein SA, Parfitt M, Jesion G, and Kleerekoper M (1989). The direct examination of three-dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 4, 3-11.
    • (1989) J Bone Miner Res , vol.4 , pp. 3-11
    • Feldkamp, L.A.1    Goldstein, S.A.2    Parfitt, M.3    Jesion, G.4    Kleerekoper, M.5
  • 20
    • 0025514438 scopus 로고
    • Evaluation of a microcomputed tomography system to study trabecular bone structure
    • Kuhn JL, Goldstein SA, Feldkamp LA, Goulet RW, and Jession G (1990). Evaluation of a microcomputed tomography system to study trabecular bone structure. J Orthop Res 8, 833-842.
    • (1990) J Orthop Res , vol.8 , pp. 833-842
    • Kuhn, J.L.1    Goldstein, S.A.2    Feldkamp, L.A.3    Goulet, R.W.4    Jession, G.5
  • 22
    • 0025662759 scopus 로고
    • A table-top CT system for high-resolution volume imaging
    • Holdsworth DW, Drangova M, Schulenberg K, and Fenster A (1990). A table-top CT system for high-resolution volume imaging. SPIE 1231, 239-245.
    • (1990) SPIE , vol.1231 , pp. 239-245
    • Holdsworth, D.W.1    Drangova, M.2    Schulenberg, K.3    Fenster, A.4
  • 23
    • 0027205207 scopus 로고
    • A high-resolution XRII-based quantitative volume CT scanner
    • Holdsworth DW, Drangova M, and Fenster A (1993). A high-resolution XRII-based quantitative volume CT scanner. Med Phys 20, 449-462.
    • (1993) Med Phys , vol.20 , pp. 449-462
    • Holdsworth, D.W.1    Drangova, M.2    Fenster, A.3
  • 24
    • 0027740028 scopus 로고
    • High resolution X-ray imaging at soft diagnostic energies using a silicon photodiode array
    • Reid BK, and Cunningham IA (1993). High resolution X-ray imaging at soft diagnostic energies using a silicon photodiode array. Med Phys 20, 1497-1504.
    • (1993) Med Phys , vol.20 , pp. 1497-1504
    • Reid, B.K.1    Cunningham, I.A.2
  • 25
    • 0343616879 scopus 로고
    • Measurement of CT resolution in 3 dimensions
    • Hearshen DO, Reimann DA, and Flynn MJ (1995). Measurement of CT resolution in 3 dimensions. Radiology 197, 291.
    • (1995) Radiology , vol.197 , pp. 291
    • Hearshen, D.O.1    Reimann, D.A.2    Flynn, M.J.3
  • 27
    • 0028403958 scopus 로고
    • Computed tomography: Part II. The practical use of a single source and detector
    • Elliott JC, Anderson P, Davis GR, Wong FSL, and Dover SD (1994). Computed tomography: Part II. The practical use of a single source and detector. JOM-J Min Met Mat Soc 46, 11-19.
    • (1994) JOM-J Min Met Mat Soc , vol.46 , pp. 11-19
    • Elliott, J.C.1    Anderson, P.2    Davis, G.R.3    Fsl, W.4    Dover, S.D.5
  • 28
    • 0342746858 scopus 로고
    • Quantitative microtomography using a 10 μm polychromatic X-ray beam from a laboratory source
    • [28] Michette AG, Morrison GR, and Buckley CJ (Eds.), Springer-Verlag
    • Davis GR, Elliott JC, and Anderson P[28] (1992). Quantitative microtomography using a 10 μm polychromatic X-ray beam from a laboratory source. In: Michette AG, Morrison GR, and Buckley CJ (Eds.), X-ray Microscopy III, Springer Series in Optical Science, Vol. 67, Springer-Verlag, pp. 458-460.
    • (1992) X-ray Microscopy III, Springer Series in Optical Science , vol.67 , pp. 458-460
    • Davis, G.R.1    Elliott, J.C.2    Anderson, P.3
  • 29
    • 0031192722 scopus 로고    scopus 로고
    • X-ray microtomography scanner using time-delay integration for elimination of ring artifacts in the reconstructed image
    • Davis GR, and Elliott JC (1997). X-ray microtomography scanner using time-delay integration for elimination of ring artifacts in the reconstructed image. Nucl Instrum Methods Phys Res Sect A 394, 157-162.
    • (1997) Nucl Instrum Methods Phys Res Sect A , vol.394 , pp. 157-162
    • Davis, G.R.1    Elliott, J.C.2
  • 30
    • 0030071062 scopus 로고    scopus 로고
    • A microtomographic system for the nondestructive evaluation of bone architecture
    • Rüegsegger P, Koller B, and Müller R (1996). A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int 58, 24-29.
    • (1996) Calcif Tissue Int , vol.58 , pp. 24-29
    • Rüegsegger, P.1    Koller, B.2    Müller, R.3
  • 31
    • 0031972279 scopus 로고    scopus 로고
    • Feldkamp and circle-and-line cone-beam reconstruction for 3-D micro-CT of vascular networks
    • Johnson RH, Hu H, Haworth ST, Cho PS, Dawson CA, and Linehan JH (1998). Feldkamp and circle-and-line cone-beam reconstruction for 3-D micro-CT of vascular networks. Phys Med Biol 43, 929-940.
    • (1998) Phys Med Biol , vol.43 , pp. 929-940
    • Johnson, R.H.1    Hu, H.2    Haworth, S.T.3    Cho, P.S.4    Dawson, C.A.5    Linehan, J.H.6
  • 32
    • 0029361349 scopus 로고
    • Methodologic aspects of computed microtomography to monitor the development of osteoporosis in gastrectomized rats
    • Stenström M, Olander B, Carlsson CA, Carlsson GA, and Hȧkanson R (1995). Methodologic aspects of computed microtomography to monitor the development of osteoporosis in gastrectomized rats. Acad Radiol 2, 785-791.
    • (1995) Acad Radiol , vol.2 , pp. 785-791
    • Stenström, M.1    Olander, B.2    Carlsson, C.A.3    Carlsson, G.A.4    Hakanson, R.5
  • 34
    • 0027881707 scopus 로고
    • A fluoroscopy-based computed-tomography scanner for small specimen research
    • Boone JM, Alexander GM, and Seibert JA (1993). A fluoroscopy-based computed-tomography scanner for small specimen research. Invest Radiol 28, 539-544.
    • (1993) Invest Radiol , vol.28 , pp. 539-544
    • Boone, J.M.1    Alexander, G.M.2    Seibert, J.A.3
  • 35
    • 0032779306 scopus 로고    scopus 로고
    • A multiple detector array helical X-ray microtomography system for specimen imaging
    • Corrigan NM, Chavez AE, Wisner ER, and Boone JM (1999). A multiple detector array helical X-ray microtomography system for specimen imaging. Med Phys 26, 1708-1713.
    • (1999) Med Phys , vol.26 , pp. 1708-1713
    • Corrigan, N.M.1    Chavez, A.E.2    Wisner, E.R.3    Boone, J.M.4
  • 36
    • 0343181519 scopus 로고    scopus 로고
    • Stratec Medizintechnik XCT Research M, Stratec Medizintechnik Gmbh, Durlacher Str. 35, D-75172 Pforzheim, Germany
    • Stratec Medizintechnik XCT Research M, Stratec Medizintechnik Gmbh, Durlacher Str. 35, D-75172 Pforzheim, Germany.
  • 39
    • 0001718569 scopus 로고
    • Optimum energies for X-ray transmission tomography of small samples: Applications of synchrotron radiation to computerized tomography
    • Grodzins L (1983). Optimum energies for X-ray transmission tomography of small samples: applications of synchrotron radiation to computerized tomography. Nucl Inst and Meth 206, 541-545.
    • (1983) Nucl Inst and Meth , vol.206 , pp. 541-545
    • Grodzins, L.1
  • 42
    • 0018177738 scopus 로고
    • Polychromatic streak artifacts in computed tomography images
    • Duerinckx AJ, and Macovski A (1978). Polychromatic streak artifacts in computed tomography images. J Comput Assist Tomogr 2, 481-487.
    • (1978) J Comput Assist Tomogr , vol.2 , pp. 481-487
    • Duerinckx, A.J.1    Macovski, A.2
  • 45
    • 0032003347 scopus 로고    scopus 로고
    • A beam hardening correction for X-ray microtomography
    • de Paiva RF, Lynch J, Rosenberg E, and Bisiaux M (1998). A beam hardening correction for X-ray microtomography. NDT&E Int 31, 17-22.
    • (1998) NDT&E Int , vol.31 , pp. 17-22
    • De Paiva, R.F.1    Lynch, J.2    Rosenberg, E.3    Bisiaux, M.4
  • 48
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head section
    • Shepp LA, and Logan BF (1974). The Fourier reconstruction of a head section. IEEE Trans Nucl Sci 21, 21-43.
    • (1974) IEEE Trans Nucl Sci , vol.21 , pp. 21-43
    • Shepp, L.A.1    Logan, B.F.2
  • 49
    • 0015116113 scopus 로고
    • Three-dimensional reconstructions from radiographs and electron micrographs
    • Ramachandran G, and Lakshminarayanan A (1971). Three-dimensional reconstructions from radiographs and electron micrographs. Proc Natl Acad Sci USA 68, 2236-2240.
    • (1971) Proc Natl Acad Sci USA , vol.68 , pp. 2236-2240
    • Ramachandran, G.1    Lakshminarayanan, A.2
  • 50
    • 0021327145 scopus 로고
    • EM Reconstruction algorithms for emission and transmission tomography
    • Lange K, and Carson RE (1984). EM Reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 8, 306-316.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.E.2
  • 51
    • 0028392927 scopus 로고
    • Maximum-likelihood reconstruction of transmission images in emission computed tomography via the EM algorithm
    • Ollinger JM (1994). Maximum-likelihood reconstruction of transmission images in emission computed tomography via the EM algorithm. IEEE Trans Med Imaging 13, 89-101.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 89-101
    • Ollinger, J.M.1
  • 52
    • 0029394375 scopus 로고
    • Globally convergent algorithms for maximum a posteriori transmission tomography
    • Lange K, and Fessler JA (1995). Globally convergent algorithms for maximum a posteriori transmission tomography. IEEE Trans Image Process 4, 1430-1438.
    • (1995) IEEE Trans Image Process , vol.4 , pp. 1430-1438
    • Lange, K.1    Fessler, J.A.2
  • 56
    • 0029734263 scopus 로고    scopus 로고
    • VOIR, a volumetric image reconstruction algorithm based on Fourier techniques for inversion of the 3-D radon transform
    • Dusaussoy NJ (1996). VOIR, a volumetric image reconstruction algorithm based on Fourier techniques for inversion of the 3-D radon transform. IEEE Trans Image Process 5, 121-131.
    • (1996) IEEE Trans Image Process , vol.5 , pp. 121-131
    • Dusaussoy, N.J.1
  • 57
    • 0032034230 scopus 로고    scopus 로고
    • An efficient Fourier method for 3-D radon inversion in exact cone-beam CT reconstruction
    • Schaller S, Flohr T, and Steffen P (1998). An efficient Fourier method for 3-D radon inversion in exact cone-beam CT reconstruction. IEEE Trans Med Imaging 17, 244-250.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 244-250
    • Schaller, S.1    Flohr, T.2    Steffen, P.3
  • 58
    • 0033431430 scopus 로고    scopus 로고
    • Iterative X-ray cone-beam tomography for metal artifact reduction and local region reconstruction
    • Wang G, Vannier MW, and Cheng PC (1999). Iterative X-ray cone-beam tomography for metal artifact reduction and local region reconstruction. Microsc Microanal 5, 58-65.
    • (1999) Microsc Microanal , vol.5 , pp. 58-65
    • Wang, G.1    Vannier, M.W.2    Cheng, P.C.3
  • 59
    • 0030278146 scopus 로고    scopus 로고
    • Local computed tomography via iterative deblurring
    • Wang G, Snyder DL, and Vannier MW (1996). Local computed tomography via iterative deblurring. Scanning 18, 582-588.
    • (1996) Scanning , vol.18 , pp. 582-588
    • Wang, G.1    Snyder, D.L.2    Vannier, M.W.3
  • 61
    • 0028913507 scopus 로고
    • Comparison of tribromoethanol, ketamine/acetylpromazine, telazol/xylazine, pentobarbital, and methoxyflurane anesthesia in HSD:ICR mice
    • Gardner DJ, Davis JA, Weina PJ, and Theune B (1995). Comparison of tribromoethanol, ketamine/acetylpromazine, telazol/xylazine, pentobarbital, and methoxyflurane anesthesia in HSD:ICR mice. Lab Anim Sci 45, 199-204.
    • (1995) Lab Anim Sci , vol.45 , pp. 199-204
    • Gardner, D.J.1    Davis, J.A.2    Weina, P.J.3    Theune, B.4
  • 62
    • 0032945137 scopus 로고    scopus 로고
    • New techniques in stereotaxic surgery and anesthesia in the mouse
    • Messier C, Emond S, and Ethier K (1999). New techniques in stereotaxic surgery and anesthesia in the mouse. Pharmacol Biochem Behav 63, 313-318.
    • (1999) Pharmacol Biochem Behav , vol.63 , pp. 313-318
    • Messier, C.1    Emond, S.2    Ethier, K.3
  • 63
    • 0027490280 scopus 로고
    • Anaesthesia of animals for biochemical research
    • Flecknell PA (1993). Anaesthesia of animals for biochemical research. Br J Anaesth 71, 885-894.
    • (1993) Br J Anaesth , vol.71 , pp. 885-894
    • Flecknell, P.A.1
  • 64
    • 0027493872 scopus 로고
    • Efficacy of tribromoethanol anesthesia in mice
    • Papaioannou VE, and Fox JG (1993). Efficacy of tribromoethanol anesthesia in mice. Lab Anim Sci 43, 189-192.
    • (1993) Lab Anim Sci , vol.43 , pp. 189-192
    • Papaioannou, V.E.1    Fox, J.G.2
  • 65
    • 0031758502 scopus 로고    scopus 로고
    • Adverse effects of tribromoethanol as used in the production of transgenic mice
    • Zeller W, Meier G, Bürki K, and Panoussis B (1997). Adverse effects of tribromoethanol as used in the production of transgenic mice. Lab Anim 43, 407-413.
    • (1997) Lab Anim , vol.43 , pp. 407-413
    • Zeller, W.1    Meier, G.2    Bürki, K.3    Panoussis, B.4
  • 66
    • 0022472176 scopus 로고
    • Effects of subchronic intermittent exposure to isoflurane in Swiss Webster mice
    • Rice SA, Baden JM, and Kundomal YR (1986). Effects of subchronic intermittent exposure to isoflurane in Swiss Webster mice. J Environ Pathol Toxicol Oncol 6, 285-293.
    • (1986) J Environ Pathol Toxicol Oncol , vol.6 , pp. 285-293
    • Rice, S.A.1    Baden, J.M.2    Kundomal, Y.R.3
  • 67
    • 0031281541 scopus 로고    scopus 로고
    • Automated feedback control of body temperature for small animal studies with MR microscopy
    • Qiu HH, Cofer GP, Hedlund LW, and Johnson GA (1997). Automated feedback control of body temperature for small animal studies with MR microscopy. IEEE Trans Biomed Eng 44, 1107-1113.
    • (1997) IEEE Trans Biomed Eng , vol.44 , pp. 1107-1113
    • Qiu, H.H.1    Cofer, G.P.2    Hedlund, L.W.3    Johnson, G.A.4
  • 68
    • 0026589325 scopus 로고
    • Postirradiation treatment with granulocyte colony-stimulating factor and preirradiation WR-2721 administration synergize to enhance hematopoietic reconstruction and increase survival
    • Patchen ML, Macvittie TJH, and Souza LM (1992). Postirradiation treatment with granulocyte colony-stimulating factor and preirradiation WR-2721 administration synergize to enhance hematopoietic reconstruction and increase survival. Int J Radiat Oncol Biol Phys, 22, 773-779.
    • (1992) Int J Radiat Oncol Biol Phys , vol.22 , pp. 773-779
    • Patchen, M.L.1    Macvittie, T.J.H.2    Souza, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.