메뉴 건너뛰기




Volumn 9, Issue 1, 2014, Pages

Imaging liver lesions using grating-based phase-contrast computed tomography with bi-lateral filter post-processing

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ARTICLE; BILE DUCT CARCINOMA; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; CONTRAST TO NOISE RATIO; DIGITAL FILTERING; EX VIVO STUDY; FATTY LIVER; FEASIBILITY STUDY; GRATING BASED PHASE CONTRAST COMPUTED TOMOGRAPHY; HISTOPATHOLOGY; IMAGE PROCESSING; IMAGE QUALITY; LIVER CELL CARCINOMA; LIVER DISEASE; LIVER HEMATOMA; LIVER METASTASIS; NOISE REDUCTION; NONHUMAN;

EID: 84898405799     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0083369     Document Type: Article
Times cited : (30)

References (39)
  • 2
    • 83655192073 scopus 로고    scopus 로고
    • Frequency of tumor entities among liver tumors of unclear etiology initially detected by sonography in the noncirrhotic or cirrhotic livers of 1349 patients. Results of the DEGUM multicenter study
    • Stuttgart, Germany : 1980
    • Seitz K, Greis C, Schuler A, Bernatik T, Blank W, et al. (2011) Frequency of tumor entities among liver tumors of unclear etiology initially detected by sonography in the noncirrhotic or cirrhotic livers of 1349 patients. Results of the DEGUM multicenter study. Ultraschall in der Medizin (Stuttgart, Germany : 1980) 32: 598-603.
    • (2011) Ultraschall in der Medizin , vol.32 , pp. 598-603
    • Seitz, K.1    Greis, C.2    Schuler, A.3    Bernatik, T.4    Blank, W.5
  • 3
    • 0035263550 scopus 로고    scopus 로고
    • Frequency of benign hepatic lesions incidentally detected with contrast-enhanced thin-section portal venous phase spiral CT
    • Stockholm, Sweden : 1987
    • Völk M, Strotzer M, Lenhart M, Techert J, Seitz J, et al. (2001) Frequency of benign hepatic lesions incidentally detected with contrast-enhanced thin-section portal venous phase spiral CT. Acta radiologica (Stockholm, Sweden : 1987) 42: 172-5.
    • (2001) Acta Radiologica , vol.42 , pp. 172-175
    • Völk, M.1    Strotzer, M.2    Lenhart, M.3    Techert, J.4    Seitz, J.5
  • 7
  • 11
    • 84858288737 scopus 로고    scopus 로고
    • Detection and classification of focal liver lesions in patients with colorectal cancer: Retrospective comparison of diffusion-weighted MR imaging and multi-slice CT
    • Eiber M, Fingerle AA, Brügel M, Gaa J, Rummeny EJ, et al. (2012) Detection and classification of focal liver lesions in patients with colorectal cancer: retrospective comparison of diffusion-weighted MR imaging and multi-slice CT. European journal of radiology 81: 683-91.
    • (2012) European Journal of Radiology , vol.81 , pp. 683-691
    • Eiber, M.1    Fingerle, A.A.2    Brügel, M.3    Gaa, J.4    Rummeny, E.J.5
  • 12
    • 84858706212 scopus 로고    scopus 로고
    • Detection, classification, and characterization of focal liver lesions: Value of diffusion-weighted MR imaging, gadoxetic acid-enhanced MR imaging and the combination of both methods
    • Holzapfel K, Eiber MJ, Fingerle AA, Bruegel M, Rummeny EJ, et al. (2012) Detection, classification, and characterization of focal liver lesions: Value of diffusion-weighted MR imaging, gadoxetic acid-enhanced MR imaging and the combination of both methods. Abdominal imaging 37: 74-82.
    • (2012) Abdominal Imaging , vol.37 , pp. 74-82
    • Holzapfel, K.1    Eiber, M.J.2    Fingerle, A.A.3    Bruegel, M.4    Rummeny, E.J.5
  • 13
    • 31544450749 scopus 로고    scopus 로고
    • Recent advances in X-ray phase imaging
    • Momose A (2005) Recent advances in X-ray phase imaging. Japanese Journal of Applied Physics 44: 6355-6367.
    • (2005) Japanese Journal of Applied Physics , vol.44 , pp. 6355-6367
    • Momose, A.1
  • 14
    • 0001349074 scopus 로고
    • An X-Ray Interferometer
    • Bonse U, Hart M (1965) An X-Ray Interferometer. Appl Phys Lett 6: 155-156.
    • (1965) Appl Phys Lett , vol.6 , pp. 155-156
    • Bonse, U.1    Hart, M.2
  • 18
    • 0033625408 scopus 로고    scopus 로고
    • Computed tomography os x-ray index of refraction using the diffraction enhanced imaging method
    • DOI 10.1088/0031-9155/45/4/309, PII S0031915500079124
    • Dilmanian FA, Zhong Z, Ren B, Wu XY, Chapman LD, et al. (2000) Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method. Physics in Medicine and Biology 45: 933-946. (Pubitemid 30196386)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.4 , pp. 933-946
    • Dilmanian, F.A.1    Zhong, Z.2    Ren, B.3    Wu, X.Y.4    Chapman, L.D.5    Orion, I.6    Thomlinson, W.C.7
  • 22
    • 57849133124 scopus 로고    scopus 로고
    • Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays
    • Bech M, Bunk O, David C, Ruth R, Rifkin J, et al. (2009) Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays. Journal of Synchrotron Radiation 16: 43-47.
    • (2009) Journal of Synchrotron Radiation , vol.16 , pp. 43-47
    • Bech, M.1    Bunk, O.2    David, C.3    Ruth, R.4    Rifkin, J.5
  • 23
    • 77954088018 scopus 로고    scopus 로고
    • Toward Clinical X-ray Phase-Contrast CT Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen
    • Donath T, Pfeiffer F, Bunk O, Gruenzweig C, Hempel E, et al. (2010) Toward Clinical X-ray Phase-Contrast CT Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen. Investigative Radiology 45: 445-452.
    • (2010) Investigative Radiology , vol.45 , pp. 445-452
    • Donath, T.1    Pfeiffer, F.2    Bunk, O.3    Gruenzweig, C.4    Hempel, E.5
  • 26
    • 34247602602 scopus 로고    scopus 로고
    • Fabrication of diffraction gratings for hard X-ray phase contrast imaging
    • DOI 10.1016/j.mee.2007.01.151, PII S0167931707001220, Proceedings of the 32nd International Conference on Micro- and Nano-Engineering
    • David C, Bruder J, Rohbeck T, Grünzweig C, Kottler C, et al. (2007) Fabrication of diffraction gratings for hard X-ray phase contrast imaging. Microelectronic Engineering 84: 1172-1177. (Pubitemid 46678358)
    • (2007) Microelectronic Engineering , vol.84 , Issue.5-8 , pp. 1172-1177
    • David, C.1    Bruder, J.2    Rohbeck, T.3    Grunzweig, C.4    Kottler, C.5    Diaz, A.6    Bunk, O.7    Pfeiffer, F.8
  • 28
    • 84873248323 scopus 로고    scopus 로고
    • Simultaneous de-noising in phase contrast tomography
    • Koehler T, Roessl E (2012) Simultaneous de-noising in phase contrast tomography. AIP Conference Proceedings 1466: 78-83.
    • (2012) AIP Conference Proceedings , vol.1466 , pp. 78-83
    • Koehler, T.1    Roessl, E.2
  • 29
    • 84881543890 scopus 로고    scopus 로고
    • Evaluation of the potential of phase-contrast computed tomography for improved visualization of cancerous human liver tissue
    • Not yet published
    • Noël PB, Herzen J, Fingerle AA, Willner M, Stockmar MK, et al. (2013) (Not yet published) Evaluation of the potential of phase-contrast computed tomography for improved visualization of cancerous human liver tissue. Zeitschrift fur medizinische Physik.
    • (2013) Zeitschrift fur Medizinische Physik
    • Noël, P.B.1    Herzen, J.2    Fingerle, A.A.3    Willner, M.4    Stockmar, M.K.5
  • 30
    • 84898475236 scopus 로고    scopus 로고
    • Assessment of grating-based X-ray phase-contrast CT for differentiation of invasive ductal carcinoma and ductal carcinoma in situ in an experimental ex vivo set-up
    • Sztrókay A, Herzen J, Auweter S, Liebhardt S, Mayr D, et al. (2012) Assessment of grating-based X-ray phase-contrast CT for differentiation of invasive ductal carcinoma and ductal carcinoma in situ in an experimental ex vivo set-up. European Radiology : 1-7.
    • (2012) European Radiology , pp. 1-7
    • Sztrókay, A.1    Herzen, J.2    Auweter, S.3    Liebhardt, S.4    Mayr, D.5
  • 31
    • 84864667363 scopus 로고    scopus 로고
    • Performance evaluation of x-ray differential phase contrast computed tomography (PCT) with respect to medical imaging
    • Raupach R, Flohr T (2012) Performance evaluation of x-ray differential phase contrast computed tomography (PCT) with respect to medical imaging. Medical Physics 39: 4761-4774.
    • (2012) Medical Physics , vol.39 , pp. 4761-4774
    • Raupach, R.1    Flohr, T.2
  • 32
    • 38849146317 scopus 로고    scopus 로고
    • Physical characteristics of GE Senographe Essential and DS digital mammography detectors
    • DOI 10.1118/1.2828185
    • Ghetti C, Borrini A, Ortenzia O, Rossi R, Ordóñez PL (2008) Physical characteristics of GE Senographe Essential and DS digital mammography detectors. Medical physics 35: 456-63. (Pubitemid 351190864)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 456-463
    • Ghetti, C.1    Borrini, A.2    Ortenzia, O.3    Rossi, R.4    Ordonez, P.L.5
  • 33
    • 79960904355 scopus 로고    scopus 로고
    • Noise properties of grating-based x-ray phase contrast computed tomography
    • Köhler T, Jürgen Engel K, Roessl E (2011) Noise properties of grating-based x-ray phase contrast computed tomography. Medical physics 38 Suppl 1: S106.
    • (2011) Medical Physics , vol.38 , Issue.SUPPL. 1
    • Köhler, T.1    Jürgen Engel, K.2    Roessl, E.3
  • 36
    • 84855446783 scopus 로고    scopus 로고
    • Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping
    • Bevins N, Zambelli J, Li K, Qi Z, Chen GH (2012) Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping. Medical physics 39: 424-8.
    • (2012) Medical Physics , vol.39 , pp. 424-428
    • Bevins, N.1    Zambelli, J.2    Li, K.3    Qi, Z.4    Chen, G.H.5
  • 39
    • 84874526406 scopus 로고    scopus 로고
    • Quantitative X-ray phase-contrast computed tomography at 82 keV
    • Willner M, Bech M, Herzen J, Zanette I, Hahn D, et al. (2013) Quantitative X-ray phase-contrast computed tomography at 82 keV. Opt Express 21: 4155-4166.
    • (2013) Opt Express , vol.21 , pp. 4155-4166
    • Willner, M.1    Bech, M.2    Herzen, J.3    Zanette, I.4    Hahn, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.