Volumn 39, Issue 8, 2012, Pages 4918-4931

Image features for misalignment correction in medical flat-detector CT

Author keywords

flat detector CT (FDCT); image quality; misalignment correction

Indexed keywords

ALIGNMENT; CALIBRATION; COMPUTERIZED TOMOGRAPHY; ENTROPY; GABOR FILTERS; GEOMETRY; GRAPHIC METHODS; HOSPITAL DATA PROCESSING; IMAGE QUALITY; MEDICAL IMAGING; PHANTOMS; TEXTURES;

EID: 84864691298     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4736532     Document Type: Article
Times cited : (55)

References (32)
  • 1
    • 0041374210 scopus 로고    scopus 로고
    • Improving 3D image quality of x-ray C-arm imaging systems by using properly designed pose determination systems for calibrating the projection geometry
    • 10.1117/12.479945
    • N. Strobel, B. Heigl, T. Brunner, O. Schütz, M. Mitschke, K. Wiesent, and T. Mertelmeier, Improving 3D image quality of x-ray C-arm imaging systems by using properly designed pose determination systems for calibrating the projection geometry., Proc. SPIE 5030, 943-954 (2003). 10.1117/12.479945
    • (2003) Proc. SPIE , vol.5030 , pp. 943-954
    • Strobel, N.1    Heigl, B.2    Brunner, T.3    Schütz, O.4    Mitschke, M.5    Wiesent, K.6    Mertelmeier, T.7
  • 2
    • 11244310646 scopus 로고    scopus 로고
    • Geometric misalignment and calibration in cone-beam tomography
    • DOI 10.1118/1.1803792
    • L. v. Smekal, M. Kachelrie, E. Stepina, and W. A. Kalender, Geometric misalignment and calibration in cone-beam tomography., Med. Phys. 31 (12), 3242-3266 (2004). 10.1118/1.1803792 (Pubitemid 40064977)
    • (2004) Medical Physics , vol.31 , Issue.12 , pp. 3242-3266
    • Von Smekal, L.1    Kachelriess, M.2    Stepina, E.3    Kalender, W.A.4
  • 3
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • DOI 10.1118/1.1869652
    • Y. Cho, D. J. Moseley, J. H. Siewerdsen, and D. A. Jaffray, Accurate technique for complete geometric calibration of cone-beam computed tomography systems., Med. Phys. 32 (4), 968-983 (2005). 10.1118/1.1869652 (Pubitemid 40586782)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4
  • 4
    • 77954753816 scopus 로고    scopus 로고
    • A generic calibration method for tomographic imaging systems with flat-panel detectors: A detailed implementation guide
    • 10.1118/1.3431996
    • X. Li, D. Zhang, and B. Liu, A generic calibration method for tomographic imaging systems with flat-panel detectors: A detailed implementation guide., Med. Phys. 37 (7), 3844-3864 (2010). 10.1118/1.3431996
    • (2010) Med. Phys. , vol.37 , Issue.7 , pp. 3844-3864
    • Li, X.1    Zhang, D.2    Liu, B.3
  • 5
    • 33744794934 scopus 로고    scopus 로고
    • A geometric calibration method for cone beam CT systems
    • DOI 10.1118/1.2198187
    • K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, A geometric calibration for cone-beam CT systems., Med. Phys. 33 (6), 1695-1706 (2006). 10.1118/1.2198187 (Pubitemid 43830258)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1695-1706
    • Yang, K.1    Kwan, A.L.C.2    Miller, D.F.3    Boone, J.M.4
  • 6
    • 21144454376 scopus 로고    scopus 로고
    • Automatic detection of fiducial markers in fluoroscopy images for on-line calibration
    • DOI 10.1118/1.1914547
    • L. Smith, M. Pleasance, R. Seeton, N. Archip, and R. Rohling, Automatic detection of fiducial markers in fluoroscopy images for on-line calibration., Med. Phys. 32 (6), 1521-1523 (2005). 10.1118/1.1914547 (Pubitemid 40880543)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1521-1523
    • Smith, L.1    Pleasance, M.2    Seeton, R.3    Archip, N.4    Rohling, R.5
  • 7
    • 47649113588 scopus 로고    scopus 로고
    • An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms
    • DOI 10.1088/0031-9155/53/14/009, PII S003191550867760X
    • D. Panetta, N. Belcari, A. Del Guerra, and S. Moehrs, An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms., Phys. Med. Biol. 53, 3841-3861 (2008). 10.1088/0031-9155/ 53/14/009 (Pubitemid 352020270)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.14 , pp. 3841-3861
    • Panetta, D.1    Belcari, N.2    Del Guerra, A.3    Moehrs, S.4
  • 8
    • 58149252286 scopus 로고    scopus 로고
    • Simultaneous misalignment correction for approximate circular cone-beam computed tomography
    • 10.1088/0031-9155/53/22/001
    • Y. Kyriakou, R. M. Lapp, L. Hillebrand, D. Ertel, and W. A. Kalender, Simultaneous misalignment correction for approximate circular cone-beam computed tomography., Phys. Med. Biol. 53, 6267-6289 (2008). 10.1088/0031-9155/53/22/001
    • (2008) Phys. Med. Biol. , vol.53 , pp. 6267-6289
    • Kyriakou, Y.1    Lapp, R.M.2    Hillebrand, L.3    Ertel, D.4    Kalender, W.A.5
  • 9
    • 80052400554 scopus 로고    scopus 로고
    • Reliable automatic alignment of tomographic projection data by passive auto-focus
    • 10.1118/1.3609096
    • A. Kingston, A. Sakellariou, T. Varslot, G. Myers, and A. Sheppard, Reliable automatic alignment of tomographic projection data by passive auto-focus., Med. Phys. 38 (9), 4934-4945 (2011). 10.1118/1.3609096
    • (2011) Med. Phys. , vol.38 , Issue.9 , pp. 4934-4945
    • Kingston, A.1    Sakellariou, A.2    Varslot, T.3    Myers, G.4    Sheppard, A.5
  • 10
    • 51849124226 scopus 로고    scopus 로고
    • Image reconstruction in circular cone-beam computed tomography by constrained, total variation minimization
    • 10.1088/0031-9155/53/17/021
    • E. Y. Sidky and X. Pan, Image reconstruction in circular cone-beam computed tomography by constrained, total variation minimization., Phys. Med. Biol. 53, 4777-4807 (2008). 10.1088/0031-9155/53/17/021
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4777-4807
    • Sidky, E.Y.1    Pan, X.2
  • 11
    • 0035104021 scopus 로고    scopus 로고
    • Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography
    • DOI 10.1088/0031-9155/46/3/318, PII S0031915501164493
    • M. Persson, D. Bone, and H. Elmqvist, Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography., Phys. Med. Biol. 46, 853-866 (2001). 10.1088/0031-9155/46/3/318 (Pubitemid 32219728)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.3 , pp. 853-866
    • Persson, M.1    Bone, D.2    Elmqvist, H.3
  • 12
    • 35048836773 scopus 로고    scopus 로고
    • Evaluation of texture features for content-based image retrieval
    • P. Howarth and S. Rüger, Evaluation of texture features for content-based image retrieval., Lect. Notes Comput. Sci. 3115, 2134-2135 (2004).
    • (2004) Lect. Notes Comput. Sci. , vol.3115 , pp. 2134-2135
    • Howarth, P.1    Rüger, S.2
  • 14
    • 0034764479 scopus 로고    scopus 로고
    • Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates
    • DOI 10.1118/1.1406514
    • M. Karolczak, S. Schaller, K. Engelke, A. Lutz, U. Taubenreuther, K. Wiesent, and W. A. Kalender, Implementation of a cone-beam reconstruction algorithm fort he single-circle source orbit with embedded misalignment correction using homogeneous coordinates., Med. Phys. 28 (10), 2050-2069 (2001). 10.1118/1.1406514 (Pubitemid 32977551)
    • (2001) Medical Physics , vol.28 , Issue.10 , pp. 2050-2069
    • Karolczak, M.1    Schaller, S.2    Engelke, K.3    Lutz, A.4    Taubenreuther, U.5    Wiesent, K.6    Kalender, W.7
  • 15
    • 0033781494 scopus 로고    scopus 로고
    • Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
    • 10.1088/0031-9155/45/11/327
    • F. Noo, R. Clackdoyle, C. Mennessier, T. A. White, and T. J. Roney, Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography., Phys. Med. Biol. 45, 3489-3508 (2000). 10.1088/0031-9155/45/11/327
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3489-3508
    • Noo, F.1    Clackdoyle, R.2    Mennessier, C.3    White, T.A.4    Roney, T.J.5
  • 16
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • 10.1016/0167-2789(92)90242-F
    • L. I. Rudin, S. Osher, and E. Fatemi, Nonlinear total variation based noise removal algorithms., Physica D: Nonlinear Phenom. 60 (1-4), 259-268 (1992). 10.1016/0167-2789(92)90242-F
    • (1992) Physica D: Nonlinear Phenom. , vol.60 , Issue.14 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 17
    • 0001556589 scopus 로고    scopus 로고
    • Iterative methods for total variation denoising
    • C. R. Vogel and M. E. Oman, Iterative methods for total variation denoising., SIAM J. Sci. Comput. (USA) 17, 227-238 (1996). 10.1137/0917016 (Pubitemid 126621162)
    • (1996) SIAM Journal of Scientific Computing , vol.17 , Issue.1 , pp. 227-238
    • Vogel, C.R.1    Oman, M.E.2
  • 18
    • 0015680481 scopus 로고
    • Textural features for image classification
    • 10.1109/TSMC.1973.4309314
    • R. M. Haralick, K. Shanmugam, and I. Dinstein, Textural features for image classification., IEEE Trans. Syst. Man Cybern. 3 (6), 610-621 (1973). 10.1109/TSMC.1973.4309314
    • (1973) IEEE Trans. Syst. Man Cybern. , vol.3 , Issue.6 , pp. 610-621
    • Haralick, R.M.1    Shanmugam, K.2    Dinstein, I.3
  • 19
    • 78650886269 scopus 로고    scopus 로고
    • Comparison of radiograph-based texture analysis and bone mineral density with three-dimensional microarchitecture of trabecular bone
    • 10.1118/1.3528125
    • P. Ranjanomennahary, A. Marchadier, M. Rachidi, and Cl. Benhamou, Comparison of radiograph-based texture analysis and bone mineral density with three-dimensional microarchitecture of trabecular bone., Med. Phys. 38 (1), 420-428 (2011). 10.1118/1.3528125
    • (2011) Med. Phys. , vol.38 , Issue.1 , pp. 420-428
    • Ranjanomennahary, P.1    Marchadier, A.2    Rachidi, M.3    Benhamou, Cl.4
  • 20
    • 0344771075 scopus 로고    scopus 로고
    • The effects of co-occurrence matrix based texture parameters on the classification of solitary pulmonary nodules imaged on computed tomography
    • 10.1016/S0895-6111(99)00033-6
    • M. F. McNitt-Gray, N. Wyckoff, J. W. Sayre, J. G. Goldin, and D. R. Aberle, The effects of co-occurrence matrix based texture parameters on the classification of solitary pulmonary nodules imaged on computed tomography., Comput. Med. Imaging Graph. 23 (6), 339-348 (1999). 10.1016/S0895-6111(99)00033- 6
    • (1999) Comput. Med. Imaging Graph. , vol.23 , Issue.6 , pp. 339-348
    • McNitt-Gray, M.F.1    Wyckoff, N.2    Sayre, J.W.3    Goldin, J.G.4    Aberle, D.R.5
  • 21
    • 0030410515 scopus 로고    scopus 로고
    • Efficient Gabor filter design for texture segmentation
    • DOI 10.1016/S0031-3203(96)00047-7, PII S0031320396000477
    • T. P. Weldon, W. E. Higgins, and D. F. Dunn, Efficient Gabor filter design for texture segmentation., Pattern Recogn. 29 (12), 2005-2015 (1996). 10.1016/S0031-3203(96)00047-7 (Pubitemid 126394632)
    • (1996) Pattern Recognition , vol.29 , Issue.12 , pp. 2005-2015
    • Weldon, T.P.1    Higgins, W.E.2    Dunn, D.F.3
  • 22
    • 0026398342 scopus 로고
    • Unsupervised texture segmentation using Gabor filters
    • 10.1016/0031-3203(91)90143-S
    • A. K. Jain and F. Farrokhnia, Unsupervised texture segmentation using Gabor filters., Pattern Recogn. 24 (12), 1167-1186 (1991). 10.1016/0031-3203(91) 90143-S
    • (1991) Pattern Recogn. , vol.24 , Issue.12 , pp. 1167-1186
    • Jain, A.K.1    Farrokhnia, F.2
  • 23
    • 0027624160 scopus 로고
    • Computational vision approach to image registration
    • DOI 10.1109/83.236535
    • Q. Zheng and R. Chellappa, A computational vision approach to image registration., IEEE Trans. Image Process. 2 (3), 311-326 (1993). 10.1109/83.236535 (Pubitemid 23697157)
    • (1993) IEEE Transactions on Image Processing , vol.2 , Issue.3 , pp. 311-326
    • Zheng Qinfen1    Chellappa Rama2
  • 24
    • 0036543747 scopus 로고    scopus 로고
    • Gabor feature based classification using the enhanced Fisher linear discriminant model for face recognition
    • DOI 10.1109/TIP.2002.999679, PII S1057714902035480
    • C. Liu and H. Wechsler, Gabor feature based classification using the enhanced fisher linear discriminant model for face recognition., IEEE Trans. Med. Image Process. 11 (4), 467-476 (2002). 10.1109/TIP.2002.999679 (Pubitemid 34692396)
    • (2002) IEEE Transactions on Image Processing , vol.11 , Issue.4 , pp. 467-476
    • Liu, C.1    Wechsler, H.2
  • 26
    • 0030130001 scopus 로고    scopus 로고
    • A new approach to image feature detection with applications
    • DOI 10.1016/0031-3203(95)00115-8
    • B. S. Manjunath, C. Shekhar, and R. Chellappa, A new approach to image feature detection with applications., Pattern Recogn. 29 (4), 627-640 (1996). 10.1016/0031-3203(95)00115-8 (Pubitemid 126398334)
    • (1996) Pattern Recognition , vol.29 , Issue.4 , pp. 627-640
    • Manjunath, B.S.1    Shekhar, C.2    Chellappa, R.3
  • 27
    • 46449092520 scopus 로고    scopus 로고
    • Effective extraction of Gabor features for adaptive mammogram retrieval
    • (IEEE, Beijing), 10.1109/ICME.2007.4284947
    • C. H. Wei, Y. Li, and C.-T. Li, Effective extraction of Gabor features for adaptive mammogram retrieval., in IEEE International Conference on Multimedia and Expo 2007 (IEEE, Beijing, 2007), pp. 1503-1506. 10.1109/ICME.2007.4284947
    • (2007) IEEE International Conference on Multimedia and Expo 2007 , pp. 1503-1506
    • Wei, C.H.1    Li, Y.2    Li, C.-T.3
  • 28
    • 0018200258 scopus 로고
    • Textural features corresponding to visual perception
    • 10.1109/TSMC.1978.4309999
    • H. Tamura, S. Mori, and T. Yamawaki, Textural features corresponding to visual perception., IEEE Trans. Syst. Man Cybern. 8 (6), 460-473 (1978). 10.1109/TSMC.1978.4309999
    • (1978) IEEE Trans. Syst. Man Cybern. , vol.8 , Issue.6 , pp. 460-473
    • Tamura, H.1    Mori, S.2    Yamawaki, T.3
  • 29
    • 85027228239 scopus 로고    scopus 로고
    • Description of the FORBILD Phantom Database, online at //www.imuni-erlangen.de/phantoms/index.htm
    • Description of the FORBILD Phantom Database, online at http: //www.imp.uni-erlangen.de/phantoms/index.htm.
  • 30
    • 35349003753 scopus 로고    scopus 로고
    • Flat-detector computed tomography (FD-CT)
    • DOI 10.1007/s00330-007-0651-9
    • W. A. Kalender and Y. Kyriakou, Flat-detector computed tomography (FD-CT)., Eur. Radiol. 17 (11), 2767-2779 (2007). 10.1007/s00330-007-0651-9 (Pubitemid 47603972)
    • (2007) European Radiology , vol.17 , Issue.11 , pp. 2767-2779
    • Kalender, W.A.1    Kyriakou, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.