Volumn 8506, Issue , 2012, Pages

First small-animal in-vivo phase-contrast micro-CT scanner

Author keywords

Grating interferometer; In vivo; Microtomography; Phase contrast; Small animal imaging

Indexed keywords

GRATING INTERFEROMETERS; IN-VIVO; MICRO-TOMOGRAPHY; PHASE CONTRASTS; SMALL ANIMAL IMAGING;

EID: 84872573701     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.929567     Document Type: Conference Paper
Times cited : (5)

References (19)
  • 1
    • 33750687279 scopus 로고    scopus 로고
    • Tomography with grating interferometers at low-brilliance sources
    • 63180S1-63180S10
    • Weitkamp, T., David, C., Kottler, C., Bunk, O. and Pfeiffer, F., "Tomography with grating interferometers at low-brilliance sources, " Proc. SPIE 6318, 63180S-1-63180S-10 (2006).
    • (2006) Proc. SPIE , vol.6318
    • Weitkamp, T.1    David, C.2    Kottler, C.3    Bunk, O.4    Pfeiffer, F.5
  • 3
    • 77954088018 scopus 로고    scopus 로고
    • Toward clinical X-ray phase-contrast CT: Demonstration of enhanced soft-tissue contrast in human specimen
    • Donath, T., Pfeiffer, F., Bunk, O., Grünzweig, C., Hempel, E., Popescu, S., Vock, P. and David, C., "Toward clinical X-ray phase-contrast CT: demonstration of enhanced soft-tissue contrast in human specimen, " Invest Radiol. 45(7), 445-452 (2010).
    • (2010) Invest Radiol , vol.45 , Issue.7 , pp. 445-452
    • Donath, T.1    Pfeiffer, F.2    Bunk, O.3    Grünzweig, C.4    Hempel, E.5    Popescu, S.6    Vock, P.7    David, C.8
  • 4
    • 33645795432 scopus 로고    scopus 로고
    • Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
    • Pfeiffer, F., Weitkamp, T., Bunk, O. and David, C., "Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources, " Nature Physics 2, 258 - 261 (2006).
    • (2006) Nature Physics , vol.2 , pp. 258-261
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3    David, C.4
  • 5
    • 66849138433 scopus 로고    scopus 로고
    • Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source
    • Herzen, J., Donath, T., Pfeiffer, F., Bunk, O., Padeste, C., Beckmann, F., Schreyer, A. and David, C., "Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source, " Optics Express 17(12), 10010-10018 (2009).
    • (2009) Optics Express , vol.17 , Issue.12 , pp. 10010-10018
    • Herzen, J.1    Donath, T.2    Pfeiffer, F.3    Bunk, O.4    Padeste, C.5    Beckmann, F.6    Schreyer, A.7    David, C.8
  • 7
    • 56249110603 scopus 로고    scopus 로고
    • 4D time-resolved micro-CT imaging for small animals
    • 707809.1-707809.8
    • Liu, X., Nadeem, F., Salmon, P.L. and Sasov, A., "4D time-resolved micro-CT imaging for small animals, " Proc. SPIE 7078, 707809.1-707809.8 (2008).
    • (2008) Proc. SPIE , vol.7078
    • Liu, X.1    Nadeem, F.2    Salmon, P.L.3    Sasov, A.4
  • 8
    • 80052295768 scopus 로고    scopus 로고
    • Development of micro-CT protocols for in vivo follow-up of mouse bone architecture without major radiation side effects
    • Laperre, K., Depypere, M., van Gastel, N., Torrekens, S., Moermans, K., Bogaerts, R., Maes, F. and Carmeliet, G., "Development of micro-CT protocols for in vivo follow-up of mouse bone architecture without major radiation side effects, " Bone 49(4), 613-622 (2011).
    • (2011) Bone , vol.49 , Issue.4 , pp. 613-622
    • Laperre, K.1    Depypere, M.2    Van Gastel, N.3    Torrekens, S.4    Moermans, K.5    Bogaerts, R.6    Maes, F.7    Carmeliet, G.8
  • 9
    • 34948900321 scopus 로고    scopus 로고
    • No effects of in vivo micro-CT radiation on structural parameters and bone marrow cells in proximal tibia of wistar rats detected after eight weekly scans
    • Brouwers, J.E., van Rietbergen, B. and Huiskes, R., "No effects of in vivo micro-CT radiation on structural parameters and bone marrow cells in proximal tibia of wistar rats detected after eight weekly scans, " J. Orthop Res. 25(10), 1325-1332 (2007).
    • (2007) J. Orthop Res , vol.25 , Issue.10 , pp. 1325-1332
    • Brouwers, J.E.1    Van Rietbergen, B.2    Huiskes, R.3
  • 10
    • 49949111063 scopus 로고    scopus 로고
    • Soft X-ray lithography of high aspect ratio SU8 submicron structures
    • Reznikova, E., Mohr, J., Boerner, M., Nazmov, V. and Jakobs, P.J., "Soft X-ray lithography of high aspect ratio SU8 submicron structures, " Microsystem Technologies 14(9-11), 1683-1688 (2008).
    • (2008) Microsystem Technologies , vol.14 , Issue.9-11 , pp. 1683-1688
    • Reznikova, E.1    Mohr, J.2    Boerner, M.3    Nazmov, V.4    Jakobs, P.J.5
  • 15
    • 33947125581 scopus 로고    scopus 로고
    • Hard x-ray phase tomography with low-brilliance sources
    • Pfeiffer, F., Kottler, C., Bunk, O. and David, C., "Hard x-ray phase tomography with low-brilliance sources, "Phys Rev Lett. 98(10), 108105 (2007).
    • (2007) Phys Rev Lett. , vol.98 , Issue.10 , pp. 108105
    • Pfeiffer, F.1    Kottler, C.2    Bunk, O.3    David, C.4
  • 17
    • 84872558025 scopus 로고    scopus 로고
    • http://sales.hamamatsu.com/en/products/solid-state-division/ x-ray-flat-panel-sensor/for-non-destructiveinspection.php.
  • 18
    • 84872514428 scopus 로고    scopus 로고
    • http://www.teledynedalsa.com/ls/products/cameradetail.aspx?partNumber= Shad-o-Box%202048.
  • 19
    • 84872529422 scopus 로고    scopus 로고
    • http://www.dexela.com/cmos.aspx.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.