-
1
-
-
0014964972
-
Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
-
COI: 1:STN:280:DyaE3c3lsVWmsg%3D%3D, PID: 5434111
-
Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283:447–51.
-
(1970)
N Engl J Med
, vol.283
, pp. 447-451
-
-
Swan, H.J.1
Ganz, W.2
Forrester, J.3
Marcus, H.4
Diamond, G.5
Chonette, D.6
-
2
-
-
84887008186
-
The pulmonary artery catheter: a critical reappraisal
-
PID: 24188220
-
Gidwani UK, Mohanty B, Chatterjee K. The pulmonary artery catheter: a critical reappraisal. Cardiol Clin. 2013;31(4):545–65.
-
(2013)
Cardiol Clin
, vol.31
, Issue.4
, pp. 545-565
-
-
Gidwani, U.K.1
Mohanty, B.2
Chatterjee, K.3
-
3
-
-
0023493373
-
A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction
-
COI: 1:STN:280:DyaL1c%2FgtlKksw%3D%3D, PID: 3652758
-
Gore JM, Goldberg RJ, Spodick DH, Alpert JS, Dalen JE. A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction. Chest. 1987;92(4):721–7.
-
(1987)
Chest.
, vol.92
, Issue.4
, pp. 721-727
-
-
Gore, J.M.1
Goldberg, R.J.2
Spodick, D.H.3
Alpert, J.S.4
Dalen, J.E.5
-
4
-
-
9544228424
-
The effectiveness of right heart catheterization in the initial care of critically ill patients
-
Connors AF Jr, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson WJ Jr, Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT investigator. JAMA. 1996;276(11):889–97.
-
(1996)
SUPPORT investigator. JAMA.
, vol.276
, Issue.11
, pp. 889-897
-
-
Connors, A.F.1
Speroff, T.2
Dawson, N.V.3
Thomas, C.4
Harrell, F.E.5
Wagner, D.6
Desbiens, N.7
Goldman, L.8
Wu, A.W.9
Califf, R.M.10
Fulkerson, W.J.11
Vidaillet, H.12
Broste, S.13
Bellamy, P.14
Lynn, J.15
Knaus, W.A.16
-
5
-
-
26044460566
-
Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial
-
PID: 16204662
-
Binanay C, Califf RM, Hasselblad V, O’Connor CM, Shah MR, Sopko G, Stevenson LW, Francis GS, Leier CV, Miller LW, ESCAPE Investigators and ESCAPE Study Coordinators. Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial. JAMA. 2005;294(13):1625–33.
-
(2005)
JAMA
, vol.294
, Issue.13
, pp. 1625-1633
-
-
Binanay, C.1
Califf, R.M.2
Hasselblad, V.3
O’Connor, C.M.4
Shah, M.R.5
Sopko, G.6
Stevenson, L.W.7
Francis, G.S.8
Leier, C.V.9
Miller, L.W.10
ESCAPE Investigators and ESCAPE Study Coordinators11
-
6
-
-
84876114914
-
Critical reappraisal of pulmonary artery catheterization and invasive hemodynamic assessment in acute heart failure
-
COI: 1:CAS:528:DC%2BC3sXlsV2nur8%3D, PID: 23570355
-
Barnett CF, Vaduganathan M, Lan G, Butler J, Gheorghiade M. Critical reappraisal of pulmonary artery catheterization and invasive hemodynamic assessment in acute heart failure. Expert Rev Cardiovasc Ther. 2013;11(4):417–24.
-
(2013)
Expert Rev Cardiovasc Ther
, vol.11
, Issue.4
, pp. 417-424
-
-
Barnett, C.F.1
Vaduganathan, M.2
Lan, G.3
Butler, J.4
Gheorghiade, M.5
-
7
-
-
80055100564
-
Lack of effectiveness of the pulmonary artery catheter in cardiac surgery
-
PID: 21918165
-
Schwann NM, Hillel Z, Hoeft A, Barash P, Möhnle P, Miao Y, Mangano DT. Lack of effectiveness of the pulmonary artery catheter in cardiac surgery. Anesth Analg. 2011;113(5):994–1002.
-
(2011)
Anesth Analg
, vol.113
, Issue.5
, pp. 994-1002
-
-
Schwann, N.M.1
Hillel, Z.2
Hoeft, A.3
Barash, P.4
Möhnle, P.5
Miao, Y.6
Mangano, D.T.7
-
8
-
-
84889259573
-
Understanding changes in established practice: pulmonary artery catheter use in critically ill patients
-
PID: 23978814
-
Gershengorn HB, Wunsch H. Understanding changes in established practice: pulmonary artery catheter use in critically ill patients. Crit Care Med. 2013;41(12):2667–76.
-
(2013)
Crit Care Med
, vol.41
, Issue.12
, pp. 2667-2676
-
-
Gershengorn, H.B.1
Wunsch, H.2
-
9
-
-
38349075756
-
Cardiac output monitoring: basic science and clinical application
-
COI: 1:STN:280:DC%2BD1c%2Fls12rsQ%3D%3D, PID: 18211449
-
Jhanji S, Dawson J, Pearse RM. Cardiac output monitoring: basic science and clinical application. Anaesthesia. 2008;63(2):172–81.
-
(2008)
Anaesthesia
, vol.63
, Issue.2
, pp. 172-181
-
-
Jhanji, S.1
Dawson, J.2
Pearse, R.M.3
-
10
-
-
84944487954
-
Researches on the circulation time in organ and on the influences which affect it
-
COI: 1:STN:280:DC%2BD2s%2FntFSktQ%3D%3D, PID: 16992112
-
Stewart GN. Researches on the circulation time in organ and on the influences which affect it. J Physiol. 1893;15:1–89.
-
(1893)
J Physiol
, vol.15
, pp. 1-89
-
-
Stewart, G.N.1
-
11
-
-
59049087035
-
The Swan–Ganz catheters: past, present, and future. Aa viewpoint
-
PID: 19124674
-
Chatterjee K. The Swan–Ganz catheters: past, present, and future. Aa viewpoint. Circulation. 2009;119:147–52.
-
(2009)
Circulation
, vol.119
, pp. 147-152
-
-
Chatterjee, K.1
-
12
-
-
0025060940
-
Complications of flow-directed balloon-tipped catheters
-
COI: 1:STN:280:DyaK3c7gslGmsw%3D%3D, PID: 2295240
-
Smart FW, Husserl FE. Complications of flow-directed balloon-tipped catheters. Chest. 1990;97(1):227–8.
-
(1990)
Chest
, vol.97
, Issue.1
, pp. 227-228
-
-
Smart, F.W.1
Husserl, F.E.2
-
13
-
-
73649094401
-
Complications associated with pulmonary artery catheters: a comprehensive clinical review
-
COI: 1:STN:280:DC%2BC3c7nsVWrtw%3D%3D, PID: 20218415
-
Evans DC, Doraiswamy VA, Prosciak MP, Silviera M, Seamon MJ, Rodriguez Funes V, Cipolla J, Wang CF, Kavuturu S, Torigian DA, Cook CH, Lindsey DE, Steinberg SM, Stawicki SP. Complications associated with pulmonary artery catheters: a comprehensive clinical review. Scand J Surg. 2009;98(4):199–208.
-
(2009)
Scand J Surg
, vol.98
, Issue.4
, pp. 199-208
-
-
Evans, D.C.1
Doraiswamy, V.A.2
Prosciak, M.P.3
Silviera, M.4
Seamon, M.J.5
Rodriguez Funes, V.6
Cipolla, J.7
Wang, C.F.8
Kavuturu, S.9
Torigian, D.A.10
Cook, C.H.11
Lindsey, D.E.12
Steinberg, S.M.13
Stawicki, S.P.14
-
14
-
-
23444461703
-
Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial
-
PID: 16084255
-
Harvey S, Harrison DA, Singer M, Ashcroft J, Jones CM, Elbourne D, Brampton W, Williams D, Young D, Rowan K, PAC-Man study collaboration. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet. 2005;366(9484):472–7.
-
(2005)
Lancet
, vol.366
, Issue.9484
, pp. 472-477
-
-
Harvey, S.1
Harrison, D.A.2
Singer, M.3
Ashcroft, J.4
Jones, C.M.5
Elbourne, D.6
Brampton, W.7
Williams, D.8
Young, D.9
Rowan, K.10
PAC-Man study collaboration11
-
15
-
-
0345374592
-
Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial
-
COI: 1:CAS:528:DC%2BD3sXpsVars74%3D, PID: 14645314
-
Richard C, Warszawski J, Anguel N, Deye N, Combes A, Barnoud D, Boulain T, Lefort Y, Fartoukh M, Baud F, Boyer A, Brochard L, Teboul JL, French Pulmonary Artery Catheter Study Group. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA. 2003;290:2713–20.
-
(2003)
JAMA.
, vol.290
, pp. 2713-2720
-
-
Richard, C.1
Warszawski, J.2
Anguel, N.3
Deye, N.4
Combes, A.5
Barnoud, D.6
Boulain, T.7
Lefort, Y.8
Fartoukh, M.9
Baud, F.10
Boyer, A.11
Brochard, L.12
Teboul, J.L.13
French Pulmonary Artery Catheter Study Group14
-
16
-
-
0025602781
-
Use of pulmonary artery catheters in patients with acute myocardial infarction
-
COI: 1:STN:280:DyaK3M%2FlvFKqtA%3D%3D, PID: 2245670
-
Zion MM, Balkin J, Rosenmann D, Goldbourt U, Reicher-Reiss H, Kaplinsky E, Behar S. Use of pulmonary artery catheters in patients with acute myocardial infarction. Chest. 1990;98:1331–5.
-
(1990)
Chest.
, vol.98
, pp. 1331-1335
-
-
Zion, M.M.1
Balkin, J.2
Rosenmann, D.3
Goldbourt, U.4
Reicher-Reiss, H.5
Kaplinsky, E.6
Behar, S.7
-
17
-
-
79958110885
-
A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
-
PID: 20966436
-
Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg. 2011;112(6):1392–402.
-
(2011)
Anesth Analg
, vol.112
, Issue.6
, pp. 1392-1402
-
-
Hamilton, M.A.1
Cecconi, M.2
Rhodes, A.3
-
18
-
-
0037413466
-
Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
-
PID: 12510037
-
Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, Laporta DP, Viner S, Passerini L, Devitt H, Kirby A, Jacka M, Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med. 2003;348:5–14.
-
(2003)
N Engl J Med.
, vol.348
, pp. 5-14
-
-
Sandham, J.D.1
Hull, R.D.2
Brant, R.F.3
Knox, L.4
Pineo, G.F.5
Doig, C.J.6
Laporta, D.P.7
Viner, S.8
Passerini, L.9
Devitt, H.10
Kirby, A.11
Jacka, M.12
-
20
-
-
84973878988
-
-
Edwardslifescience website. The FloTrac Sensor. 2014.
-
Edwardslifescience website. The FloTrac Sensor. 2014. http://www.edwards.com/products/mininvasive/pages/flotracsensor.aspx.
-
-
-
-
21
-
-
0033003166
-
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
-
COI: 1:STN:280:DC%2BD3s%2FmslCruw%3D%3D, PID: 12578081
-
Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15(2):85–91.
-
(1999)
J Clin Monit Comput
, vol.15
, Issue.2
, pp. 85-91
-
-
Critchley, L.A.1
Critchley, J.A.2
-
22
-
-
80052678524
-
Cardiac output assessed by invasive and minimally invasive techniques
-
Lee AJ, Cohn JH, Ranasinghe JS. Cardiac output assessed by invasive and minimally invasive techniques. Anesthesiol Res Pract. 2011;2011:1–17.
-
(2011)
Anesthesiol Res Pract
, vol.2011
, pp. 1-17
-
-
Lee, A.J.1
Cohn, J.H.2
Ranasinghe, J.S.3
-
23
-
-
78650833522
-
Cardiac output monitoring: is there a gold standard and how do the newer technologies compare?
-
PID: 21059611
-
Pugsley J, Lerner AB. Cardiac output monitoring: is there a gold standard and how do the newer technologies compare? Semin Cardiothorac Vasc Anesth. 2010;14(4):274–82.
-
(2010)
Semin Cardiothorac Vasc Anesth
, vol.14
, Issue.4
, pp. 274-282
-
-
Pugsley, J.1
Lerner, A.B.2
-
25
-
-
65649112876
-
Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis
-
PID: 19464625
-
Mayer J, Boldt J, Poland R, Peterson A, Manecke GR Jr. Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth. 2009;23(3):401–6.
-
(2009)
J Cardiothorac Vasc Anesth
, vol.23
, Issue.3
, pp. 401-406
-
-
Mayer, J.1
Boldt, J.2
Poland, R.3
Peterson, A.4
Manecke, G.R.5
-
26
-
-
79957547490
-
Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia
-
PID: 21624138
-
Cecconi M, Fasano N, Langiano N, Divella M, Costa MG, Rhodes A, Della Rocca G. Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia. Crit Care. 2011;15(3):R132.
-
(2011)
Crit Care
, vol.15
, Issue.3
, pp. R132
-
-
Cecconi, M.1
Fasano, N.2
Langiano, N.3
Divella, M.4
Costa, M.G.5
Rhodes, A.6
Della, R.G.7
-
27
-
-
78650414203
-
Monitoring the microcirculation in the critically ill patient: current methods and future approaches
-
PID: 20689916
-
De Backer D, Ospina-Tascon G, Salgado D, Favory R, Creteur J, Vincent JL. Monitoring the microcirculation in the critically ill patient: current methods and future approaches. Intensive Care Med. 2010;36(11):1813–25.
-
(2010)
Intensive Care Med
, vol.36
, Issue.11
, pp. 1813-1825
-
-
De Backer, D.1
Ospina-Tascon, G.2
Salgado, D.3
Favory, R.4
Creteur, J.5
Vincent, J.L.6
-
28
-
-
84863096128
-
Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output
-
PID: 22350311
-
Vasdev S, Chauhan S, Choudhury M, Hote MP, Malik M, Kiran U. Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output. J Clin Monit Comput. 2012;26:115–20.
-
(2012)
J Clin Monit Comput
, vol.26
, pp. 115-120
-
-
Vasdev, S.1
Chauhan, S.2
Choudhury, M.3
Hote, M.P.4
Malik, M.5
Kiran, U.6
-
29
-
-
80053301861
-
Phuong Tran N, Alexander BS, Laning K, Chen G, Kain ZN, Cannesson M. The impact of phenylephrine, ephedrine, and increase preload on third-generation Vigileo-Flotrac and esophageal Doppler cardiac output measurements
-
COI: 1:CAS:528:DC%2BC3MXht1WksLbJ, PID: 21821516
-
Meng L, Phuong Tran N, Alexander BS, Laning K, Chen G, Kain ZN, Cannesson M. The impact of phenylephrine, ephedrine, and increase preload on third-generation Vigileo-Flotrac and esophageal Doppler cardiac output measurements. Anesth Analg. 2011;113:751–7.
-
(2011)
Anesth Analg.
, vol.113
, pp. 751-757
-
-
Meng, L.1
-
30
-
-
84896985335
-
Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation
-
COI: 1:STN:280:DC%2BC2czlvVSksQ%3D%3D, PID: 24431387
-
Slagt C, Malagon I, Groeneveld AB. Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation. Br J Anaesth. 2014;112(4):626–37.
-
(2014)
Br J Anaesth
, vol.112
, Issue.4
, pp. 626-637
-
-
Slagt, C.1
Malagon, I.2
Groeneveld, A.B.3
-
31
-
-
84878336009
-
Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo
-
PID: 23361128
-
Marqué S, Gros A, Chimot L, Gacouin A, Lavoué S, Camus C, Le Tulzo Y. Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo. J Clin Monit Comput. 2013;27(3):273–9.
-
(2013)
J Clin Monit Comput
, vol.27
, Issue.3
, pp. 273-279
-
-
Marqué, S.1
Gros, A.2
Chimot, L.3
Gacouin, A.4
Lavoué, S.5
Camus, C.6
Le Tulzo, Y.7
-
32
-
-
84879552284
-
Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock
-
PID: 23154918
-
Slagt C, de Leeuw MA, Beute J, Rijnsburger E, Hoeksema M, Mulder JW, Malagon I, Groeneveld AB. Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock. J Clin Monit Comput. 2013;27:171–7.
-
(2013)
J Clin Monit Comput.
, vol.27
, pp. 171-177
-
-
Slagt, C.1
de Leeuw, M.A.2
Beute, J.3
Rijnsburger, E.4
Hoeksema, M.5
Mulder, J.W.6
Malagon, I.7
Groeneveld, A.B.8
-
33
-
-
57349199888
-
Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery
-
COI: 1:STN:280:DC%2BD1cjptVyisg%3D%3D, PID: 19059920
-
Biancofiore G, Critchley LA, Lee A, Bindi L, Bisà M, Esposito M, Meacci L, Mozzo R, DeSimone P, Urbani L, Filipponi F. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth. 2009;102(1):47–54.
-
(2009)
Br J Anaesth.
, vol.102
, Issue.1
, pp. 47-54
-
-
Biancofiore, G.1
Critchley, L.A.2
Lee, A.3
Bindi, L.4
Bisà, M.5
Esposito, M.6
Meacci, L.7
Mozzo, R.8
DeSimone, P.9
Urbani, L.10
Filipponi, F.11
-
34
-
-
79957512361
-
Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring highdose vasopressor therapy
-
COI: 1:CAS:528:DC%2BC3MXmsVymu7o%3D, PID: 21441548
-
Metzelder S, Coburn M, Fries M, Reinges M, Reich S, Rossaint R, Marx G, Rex S. Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring highdose vasopressor therapy. Br J Anaesth. 2011;106:776–84.
-
(2011)
Br J Anaesth.
, vol.106
, pp. 776-784
-
-
Metzelder, S.1
Coburn, M.2
Fries, M.3
Reinges, M.4
Reich, S.5
Rossaint, R.6
Marx, G.7
Rex, S.8
-
35
-
-
84858433268
-
Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients
-
COI: 1:CAS:528:DC%2BC38XksVaiu78%3D, PID: 22265900
-
Monnet X, Anguel N, Jozwiak M, Richard C, Teboul JL. Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients. Br J Anaesth. 2012;108(4):615–22. doi:10.1093/bja/aer491.
-
(2012)
Br J Anaesth
, vol.108
, Issue.4
, pp. 615-622
-
-
Monnet, X.1
Anguel, N.2
Jozwiak, M.3
Richard, C.4
Teboul, J.L.5
-
36
-
-
84888291923
-
Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach
-
PID: 24011911
-
Desebbe O, Henaine R, Keller G, Koffel C, Garcia H, Rosamel P, Obadia JF, Bastien O, Lehot JJ, Haftek M, Critchley LA. Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach. J Cardiothorac Vasc Anesth. 2013;27(6):1122–7.
-
(2013)
J Cardiothorac Vasc Anesth.
, vol.27
, Issue.6
, pp. 1122-1127
-
-
Desebbe, O.1
Henaine, R.2
Keller, G.3
Koffel, C.4
Garcia, H.5
Rosamel, P.6
Obadia, J.F.7
Bastien, O.8
Lehot, J.J.9
Haftek, M.10
Critchley, L.A.11
-
37
-
-
84887662273
-
FloTrac/Vigileo system monitoring in acute-care surgery: current and future trends
-
COI: 1:CAS:528:DC%2BC3sXhslelsr3E, PID: 24147549
-
Tsai YF, Liu FC, Yu HP. FloTrac/Vigileo system monitoring in acute-care surgery: current and future trends. Expert Rev Med Devices. 2013;10(6):717–28.
-
(2013)
Expert Rev Med Devices
, vol.10
, Issue.6
, pp. 717-728
-
-
Tsai, Y.F.1
Liu, F.C.2
Yu, H.P.3
-
38
-
-
84858159074
-
Clinical comparison of an echocardiograph derived versus pulse counter derived cardiac output measurement in abdominal aortic aneurysm surgery
-
PID: 21924632
-
Kusaka Y, Yoshitani K, Irie T, Inatomi Y, Shinzawa M, Ohnishi Y. Clinical comparison of an echocardiograph derived versus pulse counter derived cardiac output measurement in abdominal aortic aneurysm surgery. J Cardiothorac Vasc Anesth. 2012;26(2):223–6.
-
(2012)
J Cardiothorac Vasc Anesth
, vol.26
, Issue.2
, pp. 223-226
-
-
Kusaka, Y.1
Yoshitani, K.2
Irie, T.3
Inatomi, Y.4
Shinzawa, M.5
Ohnishi, Y.6
-
39
-
-
84887651628
-
Performance of third-generation Flotrac/Vigileo system during hyperdynamic therapy for delayed cerebral ischemia after subarachnoid hemorrhage
-
PID: 23061015
-
Mutoh T, Ishikawa T, Kobavashi S, Suzuki A, Yasui N. Performance of third-generation Flotrac/Vigileo system during hyperdynamic therapy for delayed cerebral ischemia after subarachnoid hemorrhage. Surg Neurol Int. 2012;3:99.
-
(2012)
Surg Neurol Int
, vol.3
, pp. 99
-
-
Mutoh, T.1
Ishikawa, T.2
Kobavashi, S.3
Suzuki, A.4
Yasui, N.5
-
40
-
-
77949305811
-
Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives
-
PID: 20185659
-
Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg. 2010;110(3):799–811.
-
(2010)
Anesth Analg
, vol.110
, Issue.3
, pp. 799-811
-
-
Reuter, D.A.1
Huang, C.2
Edrich, T.3
Shernan, S.K.4
Eltzschig, H.K.5
-
41
-
-
84861549357
-
The PiCCO monitor: a review
-
COI: 1:STN:280:DC%2BC38nitl2qtA%3D%3D, PID: 22577904
-
Litton E, Morgan M. The PiCCO monitor: a review. Anaesth Intensive Care. 2012;40(3):393–409.
-
(2012)
Anaesth Intensive Care
, vol.40
, Issue.3
, pp. 393-409
-
-
Litton, E.1
Morgan, M.2
-
42
-
-
33947104274
-
Effect of the venous catheter site on transpulmonary thermodilution measurement variables
-
PID: 17255873
-
Schmidt S, Westhoff TH, Hofmann C, Schaefer J-H, Zidek W, Compton F, van der Giet M. Effect of the venous catheter site on transpulmonary thermodilution measurement variables. Crit Care Med. 2007;35:783–6.
-
(2007)
Crit Care Med.
, vol.35
, pp. 783-786
-
-
Schmidt, S.1
Westhoff, T.H.2
Hofmann, C.3
Schaefer, J.-H.4
Zidek, W.5
Compton, F.6
van der Giet, M.7
-
43
-
-
0019969798
-
Superiority of the femoral artery of monitoring: a prospective study
-
COI: 1:STN:280:DyaL383otF2isg%3D%3D, PID: 7114367
-
Soderstrom CA, Wasserman DH, Dunham CM, Caplan ES, Cowley RA. Superiority of the femoral artery of monitoring: a prospective study. Am J Surg. 1982;144:309–12.
-
(1982)
Am J Surg
, vol.144
, pp. 309-312
-
-
Soderstrom, C.A.1
Wasserman, D.H.2
Dunham, C.M.3
Caplan, E.S.4
Cowley, R.A.5
-
44
-
-
66149118641
-
Femoral-radial arterial pressure gradients in critically ill patients
-
Gallucio ST, Chapman MJ, Finnis ME. Femoral-radial arterial pressure gradients in critically ill patients. Crit Care Resusc. 2009;11:34–8.
-
(2009)
Crit Care Resusc
, vol.11
, pp. 34-38
-
-
Gallucio, S.T.1
Chapman, M.J.2
Finnis, M.E.3
-
45
-
-
0030696028
-
Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants
-
COI: 1:STN:280:DyaK1c%2Fgs12hsw%3D%3D, PID: 9347372
-
Tibby SM, Hatherill M, Marsh MJ, Morrison G, Anderson D, Murdoch IA. Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants. Intensive Care Med. 1997;23:987–91.
-
(1997)
Intensive Care Med
, vol.23
, pp. 987-991
-
-
Tibby, S.M.1
Hatherill, M.2
Marsh, M.J.3
Morrison, G.4
Anderson, D.5
Murdoch, I.A.6
-
46
-
-
43549092418
-
Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model
-
PID: 18446111
-
Lemson J, de Boode WP, Hopman JC, Singh SK, van der Hoeven JG. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model. Pediatr Crit Care Med. 2008;9:313–9.
-
(2008)
Pediatr Crit Care Med
, vol.9
, pp. 313-319
-
-
Lemson, J.1
de Boode, W.P.2
Hopman, J.C.3
Singh, S.K.4
van der Hoeven, J.G.5
-
47
-
-
60849104458
-
Cardiac output and blood volume parameters using femoral arterial thermodilution
-
PID: 19371279
-
López-Herce J, Bustinza A, Sancho L, Mencía S, Carrillo A, Moral R, Bellón JM. Cardiac output and blood volume parameters using femoral arterial thermodilution. Pediatr Int. 2009;51:59–65.
-
(2009)
Pediatr Int
, vol.51
, pp. 59-65
-
-
López-Herce, J.1
Bustinza, A.2
Sancho, L.3
Mencía, S.4
Carrillo, A.5
Moral, R.6
Bellón, J.M.7
-
48
-
-
0242468625
-
Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
-
PID: 14605066
-
Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul J. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest. 2003;124:1900–8.
-
(2003)
Chest
, vol.124
, pp. 1900-1908
-
-
Michard, F.1
Alaya, S.2
Zarka, V.3
Bahloul, M.4
Richard, C.5
Teboul, J.6
-
49
-
-
0033001658
-
Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock
-
COI: 1:STN:280:DyaK1MzhtVWlsw%3D%3D, PID: 10382788
-
Sakka SG, Bredle DL, Reinhart K, Meier-Hellmann A. Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock. J Crit Care. 1999;14:78–83.
-
(1999)
J Crit Care
, vol.14
, pp. 78-83
-
-
Sakka, S.G.1
Bredle, D.L.2
Reinhart, K.3
Meier-Hellmann, A.4
-
50
-
-
79952965623
-
Fernández-Mondéjar E; PICS Investigators Group. Complications related to lessinvasive hemodynamic monitoring
-
COI: 1:STN:280:DC%2BC3MvmsVWgtw%3D%3D, PID: 21205627
-
Belda FJ, Aguilar G, Teboul JL, Pestaña D, Redondo FJ, Malbrain M, Luis JC, Ramasco F, Umgelter A, Wendon J, Kirov M, Fernández-Mondéjar E; PICS Investigators Group. Complications related to lessinvasive hemodynamic monitoring. Br J Anaesth. 2011;106:482–6.
-
(2011)
Br J Anaesth.
, vol.106
, pp. 482-486
-
-
Belda, F.J.1
Aguilar, G.2
Teboul, J.L.3
Pestaña, D.4
Redondo, F.J.5
Malbrain, M.6
Luis, J.C.7
Ramasco, F.8
Umgelter, A.9
Wendon, J.10
Kirov, M.11
-
51
-
-
0032817727
-
Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
-
COI: 1:STN:280:DyaK1Mzps1egsQ%3D%3D, PID: 10468257
-
Buhre W, Weyland A, Kazmaier S, Hanekop GG, Baryalei MM, Sydow M, Sonntag H. Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth. 1999;13(4):437–40.
-
(1999)
J Cardiothorac Vasc Anesth.
, vol.13
, Issue.4
, pp. 437-440
-
-
Buhre, W.1
Weyland, A.2
Kazmaier, S.3
Hanekop, G.G.4
Baryalei, M.M.5
Sydow, M.6
Sonntag, H.7
-
52
-
-
0032734448
-
Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution
-
COI: 1:STN:280:DC%2BD3c%2FktlymtQ%3D%3D, PID: 10579256
-
Goedje O, Hoeke K, Lichtwarck-Aschoff M, Faltchauser A, Lamm P, Reichart B. Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution. Crit Care Med. 1999;27(11):2407–12.
-
(1999)
Crit Care Med
, vol.27
, Issue.11
, pp. 2407-2412
-
-
Goedje, O.1
Hoeke, K.2
Lichtwarck-Aschoff, M.3
Faltchauser, A.4
Lamm, P.5
Reichart, B.6
-
53
-
-
34447523529
-
Comparison of cardiac output in OPCAB: bolus thermodilution technique versus pulse contour analysis
-
COI: 1:STN:280:DC%2BD2svot1eqtA%3D%3D, PID: 17699907
-
Sujatha P, Metha Y, Dhar A, Sarkar D, Meharwal ZS, Trehan N. Comparison of cardiac output in OPCAB: bolus thermodilution technique versus pulse contour analysis. Ann Card Anaesth. 2006;9:44–8.
-
(2006)
Ann Card Anaesth
, vol.9
, pp. 44-48
-
-
Sujatha, P.1
Metha, Y.2
Dhar, A.3
Sarkar, D.4
Meharwal, Z.S.5
Trehan, N.6
-
54
-
-
78549248199
-
Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters
-
PID: 21092290
-
Hadian M, Kim HK, Severyn DA, Pinsky MR. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care. 2010;14(6):R212.
-
(2010)
Crit Care
, vol.14
, Issue.6
, pp. R212
-
-
Hadian, M.1
Kim, H.K.2
Severyn, D.A.3
Pinsky, M.R.4
-
55
-
-
84862137287
-
Mechanical ventilation with positive end-expiratory pressure in critically ill patients: comparison of CW-Doppler ultrasound cardiac output monitoring (USCOM) and thermodilution (PiCCO)
-
PID: 22641975
-
Horster S, Stemmler HJ, Sparrer J, Tischer J, Hausmann A, Geiger S. Mechanical ventilation with positive end-expiratory pressure in critically ill patients: comparison of CW-Doppler ultrasound cardiac output monitoring (USCOM) and thermodilution (PiCCO). Acta Cardiol. 2012;67(2):177–85.
-
(2012)
Acta Cardiol
, vol.67
, Issue.2
, pp. 177-185
-
-
Horster, S.1
Stemmler, H.J.2
Sparrer, J.3
Tischer, J.4
Hausmann, A.5
Geiger, S.6
-
56
-
-
84858342283
-
® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery
-
COI: 1:STN:280:DC%2BC38zgsVCksg%3D%3D, PID: 22324797
-
® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia. 2012;67(4):377–83.
-
(2012)
Anaesthesia
, vol.67
, Issue.4
, pp. 377-383
-
-
Broch, O.1
Renner, J.2
Gruenewald, M.3
Meybohm, P.4
Schöttler, J.5
Caliebe, A.6
Steinfath, M.7
Malbrain, M.8
Bein, B.9
-
57
-
-
85009168628
-
Clinical studies of surviving sepsis bundles according to PiCCO on septic shock patients
-
PID: 24506852
-
Lu N, Zheng R, Lin H, Shao J, Yu J. Clinical studies of surviving sepsis bundles according to PiCCO on septic shock patients. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2014;26(1):23–7.
-
(2014)
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue
, vol.26
, Issue.1
, pp. 23-27
-
-
Lu, N.1
Zheng, R.2
Lin, H.3
Shao, J.4
Yu, J.5
-
58
-
-
34548663101
-
Continuous cardiac output during off-pump coronary artery bypass surgery: pulse-contour analyses vs pulmonary artery thermodilution
-
COI: 1:STN:280:DC%2BD2sris1KlsA%3D%3D, PID: 17650518
-
Halvorsen PS, Sokolov A, Cvancarova M, Hol PK, Lundblad R, Tønnessen TI. Continuous cardiac output during off-pump coronary artery bypass surgery: pulse-contour analyses vs pulmonary artery thermodilution. Br J Anaesth. 2007;99(4):484–92.
-
(2007)
Br J Anaesth
, vol.99
, Issue.4
, pp. 484-492
-
-
Halvorsen, P.S.1
Sokolov, A.2
Cvancarova, M.3
Hol, P.K.4
Lundblad, R.5
Tønnessen, T.I.6
-
59
-
-
0030832772
-
Lithium dilution cardiac output measurement: a comparison with thermodilution
-
COI: 1:STN:280:DyaK1c%2FjtlGmtw%3D%3D, PID: 9366760
-
Linton R, Band D, O’Brien T, Jonas M, Leach R. Lithium dilution cardiac output measurement: a comparison with thermodilution. Crit Care Med. 1997;25(11):1796–800.
-
(1997)
Crit Care Med
, vol.25
, Issue.11
, pp. 1796-1800
-
-
Linton, R.1
Band, D.2
O’Brien, T.3
Jonas, M.4
Leach, R.5
-
60
-
-
0032750908
-
Lithium dilution cardiac output measurements using a peripheral injection site comparison with central injection technique and thermodilution
-
COI: 1:STN:280:DC%2BD3s%2Flsleisw%3D%3D, PID: 12568133
-
Kurita T, Morita K, Kato S, Kawasaki H, Kikura K, Kazama T, Ikeda K. Lithium dilution cardiac output measurements using a peripheral injection site comparison with central injection technique and thermodilution. J Clin Monit Comput. 1999;15:279–85.
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 279-285
-
-
Kurita, T.1
Morita, K.2
Kato, S.3
Kawasaki, H.4
Kikura, K.5
Kazama, T.6
Ikeda, K.7
-
62
-
-
0024452526
-
Adverse reactions and interactions of the neuromuscular blocking drugs
-
COI: 1:STN:280:DyaK3c%2FktlajtQ%3D%3D, PID: 2682131
-
Ostergaard D, Engbaek J, Viby-Mogensen J. Adverse reactions and interactions of the neuromuscular blocking drugs. Med Toxicol Adverse Drug Exp. 1989;4(5):351–68.
-
(1989)
Med Toxicol Adverse Drug Exp
, vol.4
, Issue.5
, pp. 351-368
-
-
Ostergaard, D.1
Engbaek, J.2
Viby-Mogensen, J.3
-
63
-
-
2942564478
-
Equipment review: an appraisal of the LiDCO plus method of measuring cardiac output
-
PID: 15153237
-
Pearse RM, Ikram K, Barry J. Equipment review: an appraisal of the LiDCO plus method of measuring cardiac output. Crit Care. 2004;8(3):190–5.
-
(2004)
Crit Care
, vol.8
, Issue.3
, pp. 190-195
-
-
Pearse, R.M.1
Ikram, K.2
Barry, J.3
-
64
-
-
38849093827
-
Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter versus lithium dilution technique
-
PID: 17922106
-
Costa MG, Della Rocca D, Chiarandini G, Mattelig S, Pompei L, Barriga MS, Reynolds T, Cecconi M, Pietropaoli P. Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter versus lithium dilution technique. Intensive Care Med. 2008;34:257–63.
-
(2008)
Intensive Care Med.
, vol.34
, pp. 257-263
-
-
Costa, M.G.1
Della Rocca, D.2
Chiarandini, G.3
Mattelig, S.4
Pompei, L.5
Barriga, M.S.6
Reynolds, T.7
Cecconi, M.8
Pietropaoli, P.9
-
65
-
-
67649979831
-
Continuous cardiac index monitoring: a prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique
-
PID: 19520480
-
McCoy JV, Hollenberg SM, Dellinger RP, Arnold RC, Ruoss L, Lotano V, Peters P, Parrillo JE, Trzeciak S. Continuous cardiac index monitoring: a prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique. Resuscitation. 2009;80(8):893–7.
-
(2009)
Resuscitation.
, vol.80
, Issue.8
, pp. 893-897
-
-
McCoy, J.V.1
Hollenberg, S.M.2
Dellinger, R.P.3
Arnold, R.C.4
Ruoss, L.5
Lotano, V.6
Peters, P.7
Parrillo, J.E.8
Trzeciak, S.9
-
66
-
-
79952199467
-
Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe preeclampsia
-
COI: 1:STN:280:DC%2BC3M%2FjsFGiug%3D%3D, PID: 21097487
-
Dyer RA, Piercy JL, Reed AR, Strathie GW, Lombard CJ, Anthony JA, James MF. Comparison between pulse waveform analysis and thermodilution cardiac output determination in patients with severe preeclampsia. Br J Anaesth. 2011;106(1):77–81.
-
(2011)
Br J Anaesth.
, vol.106
, Issue.1
, pp. 77-81
-
-
Dyer, R.A.1
Piercy, J.L.2
Reed, A.R.3
Strathie, G.W.4
Lombard, C.J.5
Anthony, J.A.6
James, M.F.7
-
67
-
-
36048965479
-
Effect of vasodilation on cardiac output measured by PulseCO
-
PID: 17896183
-
Yamashita K, Nishivama T, Yokoyama T, Abe H, Manabe M. Effect of vasodilation on cardiac output measured by PulseCO. J Clin Monit Comput. 2007;21(6):335–9.
-
(2007)
J Clin Monit Comput
, vol.21
, Issue.6
, pp. 335-339
-
-
Yamashita, K.1
Nishivama, T.2
Yokoyama, T.3
Abe, H.4
Manabe, M.5
-
68
-
-
41049087999
-
Assessment of fluidresponsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echocardiography, and pulmonary artery catheter
-
PID: 18375327
-
Belloni L, Pisano A, Natale A, Piccirillo MR, Piazza L, Ismeno G, De Martino G. Assessment of fluidresponsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echocardiography, and pulmonary artery catheter. J Cardiothorac Vasc Anesth. 2008;22(2):243–8.
-
(2008)
J Cardiothorac Vasc Anesth.
, vol.22
, Issue.2
, pp. 243-248
-
-
Belloni, L.1
Pisano, A.2
Natale, A.3
Piccirillo, M.R.4
Piazza, L.5
Ismeno, G.6
De Martino, G.7
-
69
-
-
77950023186
-
Most care: a minimally invasive system for hemodynamic monitoring powered by the pressure recording analytical method (PRAM)
-
COI: 1:STN:280:DC%2BC3svhtlOntg%3D%3D
-
Romagnoli S, Bevilacqua S, Lazzeri C, Ciappi F, Dini D, Pratesi C, Gensini GF, Romano SM. Most care: a minimally invasive system for hemodynamic monitoring powered by the pressure recording analytical method (PRAM). HSR Pro Intensive Care Cardiovasc Anesth. 2009;1(2):20–7.
-
(2009)
HSR Pro Intensive Care Cardiovasc Anesth
, vol.1
, Issue.2
, pp. 20-27
-
-
Romagnoli, S.1
Bevilacqua, S.2
Lazzeri, C.3
Ciappi, F.4
Dini, D.5
Pratesi, C.6
Gensini, G.F.7
Romano, S.M.8
-
70
-
-
0036342701
-
Assessment of cardiac output from systemic arterial pressure in humans
-
PID: 12163802
-
Romano SM, Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med. 2002;30:1834–41.
-
(2002)
Crit Care Med
, vol.30
, pp. 1834-1841
-
-
Romano, S.M.1
Pistolesi, M.2
-
71
-
-
61949284877
-
Minimally invasive cardiac output monitoring in the perioperative setting
-
PID: 19224798
-
Funk DJ, Motetti EW, Gan TJ. Minimally invasive cardiac output monitoring in the perioperative setting. Anesth Analg. 2009;108:887–97.
-
(2009)
Anesth Analg
, vol.108
, pp. 887-897
-
-
Funk, D.J.1
Motetti, E.W.2
Gan, T.J.3
-
72
-
-
84888299071
-
Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery
-
PID: 23992652
-
Barile L, Landoni G, Pieri M, Ruggeri L, Maj G, Neto CN, Pasin L, Cabrini L, Zangrillo A. Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery. J Cardiothorac Vasc Anesth. 2013;27(6):1108–13.
-
(2013)
J Cardiothorac Vasc Anesth.
, vol.27
, Issue.6
, pp. 1108-1113
-
-
Barile, L.1
Landoni, G.2
Pieri, M.3
Ruggeri, L.4
Maj, G.5
Neto, C.N.6
Pasin, L.7
Cabrini, L.8
Zangrillo, A.9
-
73
-
-
79953017467
-
Cardiac output monitoring: an integrative perspective
-
PID: 21457508, (1–9)
-
Alhashemi JA, Cecconi M, Hofer CK. Cardiac output monitoring: an integrative perspective. Crit Care. 2011;15(2):214 (1–9).
-
(2011)
Crit Care
, vol.15
, Issue.2
, pp. 214
-
-
Alhashemi, J.A.1
Cecconi, M.2
Hofer, C.K.3
-
74
-
-
84872137892
-
Noninvasive cardiac output monitors: a state-of the-art review
-
PID: 22609340
-
Marik Paul E. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth. 2013;27(1):121–34.
-
(2013)
J Cardiothorac Vasc Anesth
, vol.27
, Issue.1
, pp. 121-134
-
-
Marik, P.E.1
-
75
-
-
4143134234
-
Cardiac output monitoring by pressure recording analytical method in cardiac surgery
-
PID: 15302045
-
Giomarelli P, Biagioli B, Scolletta S. Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg. 2004;26:515–20.
-
(2004)
Eur J Cardiothorac Surg
, vol.26
, pp. 515-520
-
-
Giomarelli, P.1
Biagioli, B.2
Scolletta, S.3
-
76
-
-
77950020487
-
Cardiac index validation using the pressure recording analytic method in unstable patients
-
PID: 20005131
-
Zangrillo A, Maj G, Monaco F. Cardiac index validation using the pressure recording analytic method in unstable patients. J Cardiothorac Vasc Anesth. 2010;24:265–9.
-
(2010)
J Cardiothorac Vasc Anesth.
, vol.24
, pp. 265-269
-
-
Zangrillo, A.1
Maj, G.2
Monaco, F.3
-
77
-
-
84896722234
-
Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients
-
PID: 24332994
-
Donati A, Carsetti A, Tondi S, Scorcella C, Domizi R, Damiani E, Gabbanelli V, Münch C, Adrario E, Pelaia P, Cecconi M. Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients. J Crit Care. 2014;29(2):260–4.
-
(2014)
J Crit Care
, vol.29
, Issue.2
, pp. 260-264
-
-
Donati, A.1
Carsetti, A.2
Tondi, S.3
Scorcella, C.4
Domizi, R.5
Damiani, E.6
Gabbanelli, V.7
Münch, C.8
Adrario, E.9
Pelaia, P.10
Cecconi, M.11
-
78
-
-
79952935360
-
Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients
-
COI: 1:STN:280:DC%2BC3M3otFSksA%3D%3D, PID: 21205624
-
Paarmann H, Groesdonk HV, Sedemund-Adib B, Hanke T, Heinze H, Heringlake M, Schön J. Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients. Br J Anaesth. 2011;106:475–81.
-
(2011)
Br J Anaesth.
, vol.106
, pp. 475-481
-
-
Paarmann, H.1
Groesdonk, H.V.2
Sedemund-Adib, B.3
Hanke, T.4
Heinze, H.5
Heringlake, M.6
Schön, J.7
-
79
-
-
79957734925
-
Cardiac index assessment by the pressure recording analytic method in unstable patients with atrial fibrillation
-
PID: 21147000
-
Maj G, Monaco F, Landoni G, Barile L, Nicolotti D, Pieri M, Melisurgo G. Cardiac index assessment by the pressure recording analytic method in unstable patients with atrial fibrillation. J Cardiothorac Vasc Anesth. 2011;25:476–80.
-
(2011)
J Cardiothorac Vasc Anesth.
, vol.25
, pp. 476-480
-
-
Maj, G.1
Monaco, F.2
Landoni, G.3
Barile, L.4
Nicolotti, D.5
Pieri, M.6
Melisurgo, G.7
-
80
-
-
84901789022
-
Less invasive methods of advanced hemodynamic monitoring: principles, devices, and their role in the perioperative hemodynamic optimization
-
Chamos C, Vele L, Hamilton M, Cecconi M. Less invasive methods of advanced hemodynamic monitoring: principles, devices, and their role in the perioperative hemodynamic optimization. Perioper Med (Lond). 2013;2(1):19.
-
(2013)
Perioper Med (Lond)
, vol.2
, Issue.1
, pp. 19
-
-
Chamos, C.1
Vele, L.2
Hamilton, M.3
Cecconi, M.4
-
81
-
-
84887731414
-
Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients
-
COI: 1:STN:280:DC%2BC3srovFentw%3D%3D, PID: 23625132
-
Bendjelid K, Marx G, Kiefer N, Simon TP, Geisen M, Hoeft A, Siegenthaler N, Hofer CK. Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients. Br J Anaesth. 2013;111(4):573–9.
-
(2013)
Br J Anaesth
, vol.111
, Issue.4
, pp. 573-579
-
-
Bendjelid, K.1
Marx, G.2
Kiefer, N.3
Simon, T.P.4
Geisen, M.5
Hoeft, A.6
Siegenthaler, N.7
Hofer, C.K.8
-
82
-
-
84868379180
-
The transpulmonary thermodilution technique
-
PID: 22806214
-
Sakka SG, Reuter DA. The transpulmonary thermodilution technique. J Clin Monit Comput. 2012;26:347–53.
-
(2012)
J Clin Monit Comput
, vol.26
, pp. 347-353
-
-
Sakka, S.G.1
Reuter, D.A.2
-
83
-
-
77955460209
-
Recommendations for transoesophageal echocardiography: update 2010
-
COI: 1:STN:280:DC%2BC3cjkvVSlug%3D%3D, PID: 20688767
-
Flachskampf FA, Badano L, Daniel WG, Feneck RO, Fox KF, Fraser AG, Pasquet A, Pepi M, Perez de Isla L, Zamorano JL, European Association of Echocardiography, Echo Committee of the European Association of Cardiothoracic Anaesthesiologists. Recommendations for transoesophageal echocardiography: update 2010. Eur J Echocardiogr. 2010;11:557–76.
-
(2010)
Eur J Echocardiogr
, vol.11
, pp. 557-576
-
-
Flachskampf, F.A.1
Badano, L.2
Daniel, W.G.3
Feneck, R.O.4
Fox, K.F.5
Fraser, A.G.6
Pasquet, A.7
Pepi, M.8
Perez de Isla, L.9
Zamorano, J.L.10
European Association of Echocardiography11
Echo Committee of the European Association of Cardiothoracic Anaesthesiologists12
-
85
-
-
84973880453
-
-
Liu H, Kalarickal PL, Tong Y, Inui D, Yarborough MJ, Mathew KA, Gelineau A, Fox CJ. Perioperative considerations of patients with pulmonary hypertension. In: Elwing JM, Panos RJ, editors. Chapter 9. InTech Publisher (open access); 2013. ISBN 978-953-51-1165-8
-
Liu H, Kalarickal PL, Tong Y, Inui D, Yarborough MJ, Mathew KA, Gelineau A, Fox CJ. Perioperative considerations of patients with pulmonary hypertension. In: Elwing JM, Panos RJ, editors. Chapter 9. InTech Publisher (open access); 2013. ISBN 978-953-51-1165-8. doi:10.5772/56056.
-
-
-
-
86
-
-
72549113476
-
Transesophaageal echocardiography in the OR and ICU
-
Guarracino F, Baldassarri R. Transesophaageal echocardiography in the OR and ICU. Minerva Anestesiol. 2008;75:518–29.
-
(2008)
Minerva Anestesiol
, vol.75
, pp. 518-529
-
-
Guarracino, F.1
Baldassarri, R.2
-
87
-
-
0035033332
-
The safety of intraoperative transesophageal echocardiography: a case series of 7200 cardiac surgical patients
-
COI: 1:STN:280:DC%2BD3M3mt1Gqug%3D%3D, PID: 11323333
-
Kallmeyer IJ, Collard CD, Fox JA, Body SC, Shernan SK. The safety of intraoperative transesophageal echocardiography: a case series of 7200 cardiac surgical patients. Anesth Analg. 2001;92:1126–30.
-
(2001)
Anesth Analg
, vol.92
, pp. 1126-1130
-
-
Kallmeyer, I.J.1
Collard, C.D.2
Fox, J.A.3
Body, S.C.4
Shernan, S.K.5
-
89
-
-
38049056303
-
Transoesophageal echocardiography accurately detects CO variation: a prospective comparison with thermodilution in cardiac surgery
-
COI: 1:STN:280:DC%2BD1c%2FhtF2quw%3D%3D, PID: 17672920
-
Parra V, Fita G, Rovira I, Matute P, Gomar C, Pare C. Transoesophageal echocardiography accurately detects CO variation: a prospective comparison with thermodilution in cardiac surgery. Eur J Anaesthesiol. 2008;25:135–43.
-
(2008)
Eur J Anaesthesiol
, vol.25
, pp. 135-143
-
-
Parra, V.1
Fita, G.2
Rovira, I.3
Matute, P.4
Gomar, C.5
Pare, C.6
-
90
-
-
84890564724
-
Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable
-
PID: 24192143
-
Møller-Sørensen H, Graeser K, Hansen KL, Zemtsovski M, Sander EM, Nilsson JC. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable. Acta Anaesthesiol Scand. 2014;58(1):80–8.
-
(2014)
Acta Anaesthesiol Scand
, vol.58
, Issue.1
, pp. 80-88
-
-
Møller-Sørensen, H.1
Graeser, K.2
Hansen, K.L.3
Zemtsovski, M.4
Sander, E.M.5
Nilsson, J.C.6
-
91
-
-
67650678367
-
Pulse contour analysis and transesophageal echocardiography: a comparison of measurements of cardiac output during laparoscopic colon surgery
-
PID: 19535700
-
Concha MR, Mertz VF, Cortínez LI, González KA, Butte JM. Pulse contour analysis and transesophageal echocardiography: a comparison of measurements of cardiac output during laparoscopic colon surgery. Anesth Analg. 2009;109(1):114–8.
-
(2009)
Anesth Analg
, vol.109
, Issue.1
, pp. 114-118
-
-
Concha, M.R.1
Mertz, V.F.2
Cortínez, L.I.3
González, K.A.4
Butte, J.M.5
-
92
-
-
77951177783
-
2 rebreathing
-
COI: 1:CAS:528:DC%2BC3cXntVamsbo%3D, PID: 20381727
-
2 rebreathing. Crit Care Clin. 2010;26(2):383–92.
-
(2010)
Crit Care Clin
, vol.26
, Issue.2
, pp. 383-392
-
-
Young, B.P.1
Low, L.L.2
-
93
-
-
0742287108
-
A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation
-
PID: 14652718
-
Rocco M, Spadetta G, Morelli A, Dell'Utri D, Porzi P, Conti G, Pietropaoli P. A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation. Intensive Care Med. 2004;30(1):82–7.
-
(2004)
Intensive Care Med.
, vol.30
, Issue.1
, pp. 82-87
-
-
Rocco, M.1
Spadetta, G.2
Morelli, A.3
Dell'Utri, D.4
Porzi, P.5
Conti, G.6
Pietropaoli, P.7
-
94
-
-
0036193940
-
2 rebreathing technique for cardiac output monitoring in critically ill patients
-
COI: 1:STN:280:DC%2BD383hsFegtQ%3D%3D, PID: 11942862
-
2 rebreathing technique for cardiac output monitoring in critically ill patients. Acta Anaesthesiol Scand. 2002;46(2):152–9.
-
(2002)
Acta Anaesthesiol Scand
, vol.46
, Issue.2
, pp. 152-159
-
-
Odenstedt, H.1
Stenqvist, O.2
Lundin, S.3
-
95
-
-
33749078184
-
Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter
-
COI: 1:STN:280:DC%2BD28rivF2nug%3D%3D, PID: 16953944
-
Gueret G, Kiss G, Rossignol B, Bezon E, Wargnier JP, Miossec A, Corre O, Arvieux CC. Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter. Eur J Anaesthesiol. 2006;23:848–54.
-
(2006)
Eur J Anaesthesiol.
, vol.23
, pp. 848-854
-
-
Gueret, G.1
Kiss, G.2
Rossignol, B.3
Bezon, E.4
Wargnier, J.P.5
Miossec, A.6
Corre, O.7
Arvieux, C.C.8
-
96
-
-
34648834522
-
Evaluation of partial carbon dioxide rebreathing CO measurement during thoracic surgery
-
COI: 1:CAS:528:DC%2BD2sXhtlSlurzI, PID: 17905269
-
Ng JM, Chow MY, Ip-Yam PC, Goh MH, Agasthian T. Evaluation of partial carbon dioxide rebreathing CO measurement during thoracic surgery. J Cardiothorac Vasc Anesth. 2007;21:655–8.
-
(2007)
J Cardiothorac Vasc Anesth
, vol.21
, pp. 655-658
-
-
Ng, J.M.1
Chow, M.Y.2
Ip-Yam, P.C.3
Goh, M.H.4
Agasthian, T.5
-
98
-
-
29844448951
-
Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model
-
COI: 1:STN:280:DC%2BD28%2FgsVyrug%3D%3D, PID: 16390561
-
Bajorat J, Hofmockel R, Vagts DA, Janda M, Pohl B, Beck C, Noeldge-Schomburg G. Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol. 2006;23(1):23–30.
-
(2006)
Eur J Anaesthesiol
, vol.23
, Issue.1
, pp. 23-30
-
-
Bajorat, J.1
Hofmockel, R.2
Vagts, D.A.3
Janda, M.4
Pohl, B.5
Beck, C.6
Noeldge-Schomburg, G.7
-
99
-
-
0035998335
-
Equipment review: new techniques for cardiac output measurement: oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis
-
PID: 12133181
-
Berton C, Cholley B. Equipment review: new techniques for cardiac output measurement: oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis. Crit Care. 2002;6:216–21.
-
(2002)
Crit Care
, vol.6
, pp. 216-221
-
-
Berton, C.1
Cholley, B.2
-
100
-
-
34248191969
-
Comparison of cardiac outputs during major surgery using the DeltexCardioQoesophageal Doppler monitor and the Novametrix-Respironics NICO: a prospective observational study
-
COI: 1:STN:280:DC%2BD2s3pvVemsw%3D%3D, PID: 17509500
-
Green DW. Comparison of cardiac outputs during major surgery using the DeltexCardioQoesophageal Doppler monitor and the Novametrix-Respironics NICO: a prospective observational study. Int J Surg. 2007;5(3):176–82.
-
(2007)
Int J Surg
, vol.5
, Issue.3
, pp. 176-182
-
-
Green, D.W.1
-
101
-
-
0037394040
-
Comparison of continuous cardiac output measurements in patients after cardiac surgery
-
PID: 12698404
-
Mielck F, Buhre W, Hanekop G, Tirilomis T, Hilgers R, Sonntag H. Comparison of continuous cardiac output measurements in patients after cardiac surgery. J Cardiothorac Vasc Anesth. 2003;17(2):211–6.
-
(2003)
J Cardiothorac Vasc Anesth
, vol.17
, Issue.2
, pp. 211-216
-
-
Mielck, F.1
Buhre, W.2
Hanekop, G.3
Tirilomis, T.4
Hilgers, R.5
Sonntag, H.6
-
102
-
-
77951150728
-
Techniques for determining cardiac output in the intensive care unit
-
PID: 20381725
-
Mohammed I, Phillips C. Techniques for determining cardiac output in the intensive care unit. Crit Care Clin. 2010;26(2):355–64.
-
(2010)
Crit Care Clin
, vol.26
, Issue.2
, pp. 355-364
-
-
Mohammed, I.1
Phillips, C.2
-
103
-
-
34447131664
-
Noninvasive cardiac output monitoring (NICOM): a clinical validation
-
PID: 17458538
-
Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med. 2007;33(7):1191–4.
-
(2007)
Intensive Care Med
, vol.33
, Issue.7
, pp. 1191-1194
-
-
Squara, P.1
Denjean, D.2
Estagnasie, P.3
Brusset, A.4
Dib, J.C.5
Dubois, C.6
-
104
-
-
47549096309
-
Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
-
PID: 18628220
-
Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134:172–8.
-
(2008)
Chest
, vol.134
, pp. 172-178
-
-
Marik, P.E.1
Baram, M.2
Vahid, B.3
-
105
-
-
84887371298
-
Comparison of cardiac output derived from FloTrac™/Vigileo™ and impedance cardiography during major abdominal surgery
-
PID: 23803309
-
Kim JY, Kim BR, Lee KH, Kim KW, Kim JH, Lee SI, Kim KT, Choe WJ, Park JS, Kim JW. Comparison of cardiac output derived from FloTrac™/Vigileo™ and impedance cardiography during major abdominal surgery. J Int Med Res. 2013;41(4):1342–9.
-
(2013)
J Int Med Res
, vol.41
, Issue.4
, pp. 1342-1349
-
-
Kim, J.Y.1
Kim, B.R.2
Lee, K.H.3
Kim, K.W.4
Kim, J.H.5
Lee, S.I.6
Kim, K.T.7
Choe, W.J.8
Park, J.S.9
Kim, J.W.10
-
106
-
-
84934439337
-
Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery
-
PID: 25381090
-
Cheung H, Dong Q, Dong R, Yu B. Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery. J Anesth. 2015;29(3):416–20.
-
(2015)
J Anesth
, vol.29
, Issue.3
, pp. 416-420
-
-
Cheung, H.1
Dong, Q.2
Dong, R.3
Yu, B.4
-
107
-
-
41949125848
-
Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique
-
PID: 18340540
-
Raval NY, Squara P, Cleman M, Yalamanchili K, Winklmaier M, Burkhoff D. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput. 2008;22(2):113–9.
-
(2008)
J Clin Monit Comput
, vol.22
, Issue.2
, pp. 113-119
-
-
Raval, N.Y.1
Squara, P.2
Cleman, M.3
Yalamanchili, K.4
Winklmaier, M.5
Burkhoff, D.6
-
108
-
-
67249088798
-
Comparison between Flotrac-Vigileo and bioreactance, a totally noninvasive method for cardiac output monitoring
-
Marqué S, Cariou A, Chiche JD, Squara P. Comparison between Flotrac-Vigileo and bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care. 2009;13(3):1–6.
-
(2009)
Crit Care
, vol.13
, Issue.3
, pp. 1-6
-
-
Marqué, S.1
Cariou, A.2
Chiche, J.D.3
Squara, P.4
-
109
-
-
68849112910
-
Comparison of monitoring performance of bioreactance vs. pulse contour during lung recruitment maneuvers
-
Squara P, Rotcajg D, Denjean D, Estagnasie P, Brusset A. Comparison of monitoring performance of bioreactance vs. pulse contour during lung recruitment maneuvers. Crit Care. 2009;13(4):125–31.
-
(2009)
Crit Care
, vol.13
, Issue.4
, pp. 125-131
-
-
Squara, P.1
Rotcajg, D.2
Denjean, D.3
Estagnasie, P.4
Brusset, A.5
-
110
-
-
84887913010
-
Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients
-
COI: 1:STN:280:DC%2BC3sbjtFOiug%3D%3D, PID: 23985531
-
Kupersztych-Hagege E, Teboul JL, Artigas A, Talbot A, Sabatier C, Richard C, Monnet X. Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. Br J Anaesth. 2013;111(6):961–6.
-
(2013)
Br J Anaesth
, vol.111
, Issue.6
, pp. 961-966
-
-
Kupersztych-Hagege, E.1
Teboul, J.L.2
Artigas, A.3
Talbot, A.4
Sabatier, C.5
Richard, C.6
Monnet, X.7
-
111
-
-
84903718669
-
Quantifying tissue mechanical properties using photoplethysmography
-
PID: 25071970, (eCollection 2014)
-
Akl TJ, Wilson MA, Ericson MN, Coté GL. Quantifying tissue mechanical properties using photoplethysmography. Biomed Opt Express. 2014;5(7):2362–75. doi:10.1364/BOE.5.002362 (eCollection 2014).
-
(2014)
Biomed Opt Express
, vol.5
, Issue.7
, pp. 2362-2375
-
-
Akl, T.J.1
Wilson, M.A.2
Ericson, M.N.3
Coté, G.L.4
-
112
-
-
84973889289
-
Totally non-invasive continuous cardiac output measurement with the Nexfin CO-Trek
-
Perel A, Settels JJ. Totally non-invasive continuous cardiac output measurement with the Nexfin CO-Trek. Ann Update Intensive Care Emerg Med. 2011;1:434–42.
-
(2011)
Ann Update Intensive Care Emerg Med
, vol.1
, pp. 434-442
-
-
Perel, A.1
Settels, J.J.2
-
113
-
-
84973884146
-
-
Edwards lifescienes: the ClearSight system. 2014.
-
Edwards lifescienes: the ClearSight system. 2014. http://www.edwards.com/products/mininvasive/Pages/clearsightsystem.aspx.
-
-
-
-
114
-
-
80053589129
-
Comparison of invasive and non-invasive measurements of haemodynamic parameters in patients with advanced heart failure
-
Sokolski M, Rydlewska A, Krakowiak B, Biegus J, Zymlinski R, Banasiak W, Jankowska EA, Ponikowski P. Comparison of invasive and non-invasive measurements of haemodynamic parameters in patients with advanced heart failure. J Cardiovasc Med (Hagerstown). 2011;12(11):773–8.
-
(2011)
J Cardiovasc Med (Hagerstown)
, vol.12
, Issue.11
, pp. 773-778
-
-
Sokolski, M.1
Rydlewska, A.2
Krakowiak, B.3
Biegus, J.4
Zymlinski, R.5
Banasiak, W.6
Jankowska, E.A.7
Ponikowski, P.8
-
115
-
-
78049488760
-
Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
-
COI: 1:STN:280:DC%2BC3cbgsFCqug%3D%3D, PID: 20860647
-
Bogert LW, Wesseling KH, Schraa O, Van Lieshout EJ, de Mol BA, van Goudoever J, Westerhof BE, van Lieshout JJ. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia. 2010;65(11):1119–25.
-
(2010)
Anaesthesia
, vol.65
, Issue.11
, pp. 1119-1125
-
-
Bogert, L.W.1
Wesseling, K.H.2
Schraa, O.3
Van Lieshout, E.J.4
de Mol, B.A.5
van Goudoever, J.6
Westerhof, B.E.7
van Lieshout, J.J.8
-
116
-
-
84890036222
-
Nexfin noninvasive continuous hemodynamic monitoring: validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients
-
Ameloot K, Van De Vijver K, Broch O, Van Regenmortel N, De Laet I, Schoonheydt K, Dits H, Bein B, Malbrain ML. Nexfin noninvasive continuous hemodynamic monitoring: validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients. Sci World J. 2013;2013:519080.
-
(2013)
Sci World J
, vol.2013
, pp. 519080
-
-
Ameloot, K.1
Van De Vijver, K.2
Broch, O.3
Van Regenmortel, N.4
De Laet, I.5
Schoonheydt, K.6
Dits, H.7
Bein, B.8
Malbrain, M.L.9
-
117
-
-
84861121516
-
Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output
-
PID: 22608585
-
Van der Spoel AG, Voogel AJ, Folkers A, Boer C, Bouwman RA. Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output. J Clin Anesth. 2012;24(4):304–9.
-
(2012)
J Clin Anesth
, vol.24
, Issue.4
, pp. 304-309
-
-
Van der Spoel, A.G.1
Voogel, A.J.2
Folkers, A.3
Boer, C.4
Bouwman, R.A.5
-
118
-
-
70449646306
-
Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in clinically ill patients
-
Stover JF, Stocker R, Lenherr R, Neff TA, Cottini SR, Zoller B, Béchir M. Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in clinically ill patients. BMC Anesthesiol. 2009;12(9):6.
-
(2009)
BMC Anesthesiol
, vol.12
, Issue.9
, pp. 6
-
-
Stover, J.F.1
Stocker, R.2
Lenherr, R.3
Neff, T.A.4
Cottini, S.R.5
Zoller, B.6
Béchir, M.7
-
119
-
-
0027227933
-
Invasive hemodynamic monitoring in obstetrics and gynecology: ACOG technical bulletin no. 175
-
American College of Obstetricians and Gynecologists. Invasive hemodynamic monitoring in obstetrics and gynecology: ACOG technical bulletin no. 175. Int J Gynaecol Obstet. 1993;42:199–205.
-
(1993)
Int J Gynaecol Obstet
, vol.42
, pp. 199-205
-
-
American College of Obstetricians and Gynecologists1
-
120
-
-
0141655120
-
Practice guidelines for pulmonary artery catheterization: an updated report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization
-
American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization. Practice guidelines for pulmonary artery catheterization: an updated report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization. Anesthesiology. 2003;99(4):988–1014.
-
(2003)
Anesthesiology
, vol.99
, Issue.4
, pp. 988-1014
-
-
American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization1
-
121
-
-
79953827557
-
Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients
-
PID: 21153399
-
De Backer D, Marx G, Tan A. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. 2011;37:233–40.
-
(2011)
Intensive Care Med
, vol.37
, pp. 233-240
-
-
De Backer, D.1
Marx, G.2
Tan, A.3
-
122
-
-
84855816724
-
Clinical utility of biomarkers of endothelial activation in sepsis: a systematic review
-
PID: 22248019
-
Xing K, Murthy S, Liles WC, Singh JM. Clinical utility of biomarkers of endothelial activation in sepsis: a systematic review. Crit Care. 2012;16(1):R7.
-
(2012)
Crit Care
, vol.16
, Issue.1
, pp. R7
-
-
Xing, K.1
Murthy, S.2
Liles, W.C.3
Singh, J.M.4
-
123
-
-
4444233598
-
Persistent microcirculatory alterations are associated with organ failure and death in patients with septic shock
-
PID: 15343008
-
Sakr Y, Dubois MJ, De Backer D, Creteur J, Vincent JL. Persistent microcirculatory alterations are associated with organ failure and death in patients with septic shock. Crit Care Med. 2004;32:1825–31.
-
(2004)
Crit Care Med
, vol.32
, pp. 1825-1831
-
-
Sakr, Y.1
Dubois, M.J.2
De Backer, D.3
Creteur, J.4
Vincent, J.L.5
-
124
-
-
84855817728
-
Clinical review: update on hemodynamic monitoring—a consensus of 16
-
PID: 21884645
-
Vincent JL, Rhodes A, Perel A, Martin GS, Della Rocca G, Vallet B, Pinsky MR, Hofer CK, Teboul JL, de Boode WP, Scolletta S, Vieillard-Baron A, De Backer D, Walley KR, Maggiorini M, Singer M. Clinical review: update on hemodynamic monitoring—a consensus of 16. Crit Care. 2011;15(4):229.
-
(2011)
Crit Care
, vol.15
, Issue.4
, pp. 229
-
-
Vincent, J.L.1
Rhodes, A.2
Perel, A.3
Martin, G.S.4
Della Rocca, G.5
Vallet, B.6
Pinsky, M.R.7
Hofer, C.K.8
Teboul, J.L.9
de Boode, W.P.10
Scolletta, S.11
Vieillard-Baron, A.12
De Backer, D.13
Walley, K.R.14
Maggiorini, M.15
Singer, M.16
|