Noninvasive Monitoring Cardiac Output Using Partial CO2 Rebreathing

Author keywords

Cardiac output; Hemodynamic monitoring; NICO; Partial CO2 rebreathing

Indexed keywords

ACUTE LUNG INJURY; ARTERIAL CARBON DIOXIDE TENSION; ARTIFICIAL VENTILATION; CARBON DIOXIDE BREATHING; CARDIOPULMONARY BYPASS; CHRONIC LUNG DISEASE; CRITICALLY ILL PATIENT; DIAGNOSTIC ACCURACY; EMERGENCY HEALTH SERVICE; END TIDAL CARBON DIOXIDE TENSION; GERIATRICS; HEART FUNCTION; HEART OUTPUT; HEART OUTPUT MEASUREMENT; HEMODYNAMICS; HIP SURGERY; HUMAN; INTENSIVE CARE UNIT; NON INVASIVE MEASUREMENT; NONINVASIVE CARDIAC OUTPUT; OXYGEN CONSUMPTION; PEDIATRICS; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; REVIEW; SURGICAL TECHNIQUE; THERMODILUTION; THORAX SURGERY; VALIDATION PROCESS;

EID: 77951177783     PISSN: 07490704     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ccc.2009.12.002     Document Type: Review
Times cited : (16)

References (36)
  • 2
    • 0036139802 scopus 로고    scopus 로고
    • Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures
    • Venn R., Steele A., Richardson P., et al. Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 2002, 88(1):65-71.
    • (2002) Br J Anaesth , vol.88 , Issue.1 , pp. 65-71
    • Venn, R.1    Steele, A.2    Richardson, P.3
  • 3
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan H., Ganz W., Forrester J., et al. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970, 283(9):447-451.
    • (1970) N Engl J Med , vol.283 , Issue.9 , pp. 447-451
    • Swan, H.1    Ganz, W.2    Forrester, J.3
  • 4
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PACMan): a randomized controlled trial
    • Harvey S., Harrison D.A., Singer M., et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PACMan): a randomized controlled trial. Lancet 2005, 366(9484):472-477.
    • (2005) Lancet , vol.366 , Issue.9484 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 5
    • 34249089562 scopus 로고    scopus 로고
    • What technique should I use to measure cardiac output?
    • Hofer C.K., Ganter M.T., Zollinger A. What technique should I use to measure cardiac output?. Curr Opin Crit Care 2007, 13(3):308-317.
    • (2007) Curr Opin Crit Care , vol.13 , Issue.3 , pp. 308-317
    • Hofer, C.K.1    Ganter, M.T.2    Zollinger, A.3
  • 6
    • 26944486636 scopus 로고    scopus 로고
    • Noninvasive techniques for measurements of cardiac output
    • Cholley B.P., Payen D. Noninvasive techniques for measurements of cardiac output. Curr Opin Crit Care 2005, 11(5):424-429.
    • (2005) Curr Opin Crit Care , vol.11 , Issue.5 , pp. 424-429
    • Cholley, B.P.1    Payen, D.2
  • 7
    • 0036800276 scopus 로고    scopus 로고
    • Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology
    • Chaney J.C., Derdak S. Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology. Crit Care Med 2002, 30(10):2338-2345.
    • (2002) Crit Care Med , vol.30 , Issue.10 , pp. 2338-2345
    • Chaney, J.C.1    Derdak, S.2
  • 8
    • 0031001405 scopus 로고    scopus 로고
    • Partial carbon dioxide rebreathing: a reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow
    • de Abreu M.G., Quintel M., Ragaller M., et al. Partial carbon dioxide rebreathing: a reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow. Crit Care Med 1997, 25(4):675-683.
    • (1997) Crit Care Med , vol.25 , Issue.4 , pp. 675-683
    • de Abreu, M.G.1    Quintel, M.2    Ragaller, M.3
  • 9
    • 0036118488 scopus 로고    scopus 로고
    • Evaluation of a new device for noninvasive measurement of nonshunted pulmonary capillary blood flow in patients with acute lung injury
    • de Abreu M.G., Geiger S., Winkler T., et al. Evaluation of a new device for noninvasive measurement of nonshunted pulmonary capillary blood flow in patients with acute lung injury. Intensive Care Med 2002, 289(3):318-323.
    • (2002) Intensive Care Med , vol.289 , Issue.3 , pp. 318-323
    • de Abreu, M.G.1    Geiger, S.2    Winkler, T.3
  • 10
    • 0024400564 scopus 로고
    • Measurement of cardiac output by carbon dioxide rebreathing methods
    • Heigenhauser G.J., Jones N.L. Measurement of cardiac output by carbon dioxide rebreathing methods. Clin Chest Med 1989, 10(2):255-264.
    • (1989) Clin Chest Med , vol.10 , Issue.2 , pp. 255-264
    • Heigenhauser, G.J.1    Jones, N.L.2
  • 11
    • 0033238015 scopus 로고    scopus 로고
    • 2 rebreathing cardiac output-operating principles of the NICO system
    • 2 rebreathing cardiac output-operating principles of the NICO system. J Clin Monit Comput 1999, 15(6):387-401.
    • (1999) J Clin Monit Comput , vol.15 , Issue.6 , pp. 387-401
    • Jaffe, M.B.1
  • 13
    • 0033864048 scopus 로고    scopus 로고
    • Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit
    • van Heerden P.V., Baker S., Lim S.I., et al. Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit. Anaesth Intensive Care 2000, 28(4):427-430.
    • (2000) Anaesth Intensive Care , vol.28 , Issue.4 , pp. 427-430
    • van Heerden, P.V.1    Baker, S.2    Lim, S.I.3
  • 14
    • 0034963214 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output
    • Nilsson L.B., Eldrup N., Berthelsen P.G. Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output. Acta Anaesthesiol Scand 2001, 45(6):680-685.
    • (2001) Acta Anaesthesiol Scand , vol.45 , Issue.6 , pp. 680-685
    • Nilsson, L.B.1    Eldrup, N.2    Berthelsen, P.G.3
  • 16
    • 33644826320 scopus 로고    scopus 로고
    • Measurement of cardiac output after cardiac surgery: validation fo a partial carbon dioxide rebreathing (NICO) system in comparison with continous thermodilution with a pulmonary artery catheter
    • [in Spanish]
    • Jover J.L., Soro M., Belda F.J., et al. Measurement of cardiac output after cardiac surgery: validation fo a partial carbon dioxide rebreathing (NICO) system in comparison with continous thermodilution with a pulmonary artery catheter. Rev Esp Anestesiol Reanim 2005, 52(5):256-262. [in Spanish].
    • (2005) Rev Esp Anestesiol Reanim , vol.52 , Issue.5 , pp. 256-262
    • Jover, J.L.1    Soro, M.2    Belda, F.J.3
  • 17
    • 77951184034 scopus 로고    scopus 로고
    • Cardiac output measurement using the non-invasive cardiac output (NICO) monitor: a comparative study with the standard thermodilution technique
    • Kimura C., Kunimoto F., Morishita Y. Cardiac output measurement using the non-invasive cardiac output (NICO) monitor: a comparative study with the standard thermodilution technique. Jpn J Thorac Cardiovasc Surg 2004, 33(1):6-8.
    • (2004) Jpn J Thorac Cardiovasc Surg , vol.33 , Issue.1 , pp. 6-8
    • Kimura, C.1    Kunimoto, F.2    Morishita, Y.3
  • 18
    • 0036193940 scopus 로고    scopus 로고
    • 2 rebreathing technique for cardiac output monitoring in critically ill patients
    • 2 rebreathing technique for cardiac output monitoring in critically ill patients. Acta Anaesthesiol Scand 2002, 46(2):152-159.
    • (2002) Acta Anaesthesiol Scand , vol.46 , Issue.2 , pp. 152-159
    • Odenstedt, H.1    Stenqvist, O.2    Lundin, S.3
  • 19
    • 17744382825 scopus 로고    scopus 로고
    • The relationship between cardiac output measured by the thermodilution method and that measured by the carbon dioxide rebreathing technique during laparoscopic surgery
    • Suzuki M., Koda S., Nakamura Y., et al. The relationship between cardiac output measured by the thermodilution method and that measured by the carbon dioxide rebreathing technique during laparoscopic surgery. Anesth Analg 2005, 100(5):1381-1383.
    • (2005) Anesth Analg , vol.100 , Issue.5 , pp. 1381-1383
    • Suzuki, M.1    Koda, S.2    Nakamura, Y.3
  • 21
    • 0028026349 scopus 로고
    • Carbon dioxide rebreathing method of cardiac output measurement during acute respiratory failure in patients with chronic obstructive pulmonary disease
    • Neviere R., Mathieu D., Riou Y., et al. Carbon dioxide rebreathing method of cardiac output measurement during acute respiratory failure in patients with chronic obstructive pulmonary disease. Crit Care Med 1994, 22(1):81-85.
    • (1994) Crit Care Med , vol.22 , Issue.1 , pp. 81-85
    • Neviere, R.1    Mathieu, D.2    Riou, Y.3
  • 23
    • 0036676068 scopus 로고    scopus 로고
    • Partial CO(2) rebreathing technique versus thermodilution: measurement of cardiac output before and after operations with extracorporeal circulation
    • [in German]
    • Neuhäuser C., Müller M., Bräu M., et al. Partial CO(2) rebreathing technique versus thermodilution: measurement of cardiac output before and after operations with extracorporeal circulation. Anaesthesist 2002, 51(8):625-633. [in German].
    • (2002) Anaesthesist , vol.51 , Issue.8 , pp. 625-633
    • Neuhäuser, C.1    Müller, M.2    Bräu, M.3
  • 25
    • 34648834522 scopus 로고    scopus 로고
    • Evaluation of partial carbon dioxide rebreathing cardiac output measurement during thoracic surgery
    • Ng J.M., Chow M.Y., Ip-Yam P.C., et al. Evaluation of partial carbon dioxide rebreathing cardiac output measurement during thoracic surgery. J Cardiothorac Vasc Anesth 2007, 21(5):655-658.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , Issue.5 , pp. 655-658
    • Ng, J.M.1    Chow, M.Y.2    Ip-Yam, P.C.3
  • 26
    • 33749078184 scopus 로고    scopus 로고
    • Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter
    • Gueret G., Kiss G., Rossignol B., et al. Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter. Eur J Anaesthesiol 2006, 23(10):848-854.
    • (2006) Eur J Anaesthesiol , vol.23 , Issue.10 , pp. 848-854
    • Gueret, G.1    Kiss, G.2    Rossignol, B.3
  • 27
    • 0028072122 scopus 로고
    • Non-invasive measurement of cardiac output in patients with acute lung injury using the carbon dioxide rebreathing method
    • Neviere R., Mathieu D., Riou Y., et al. Non-invasive measurement of cardiac output in patients with acute lung injury using the carbon dioxide rebreathing method. Clin Intensive Care 1994, 5(4):172-175.
    • (1994) Clin Intensive Care , vol.5 , Issue.4 , pp. 172-175
    • Neviere, R.1    Mathieu, D.2    Riou, Y.3
  • 28
    • 13244255445 scopus 로고    scopus 로고
    • Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury
    • Valiatti J.L., Amaral J.L. Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury. Sao Paulo Med J 2004, 122(6):233-238.
    • (2004) Sao Paulo Med J , vol.122 , Issue.6 , pp. 233-238
    • Valiatti, J.L.1    Amaral, J.L.2
  • 29
    • 0037289834 scopus 로고    scopus 로고
    • 2 rebreathing technique under different hemodynamic and ventilation/perfusion matching conditions
    • 2 rebreathing technique under different hemodynamic and ventilation/perfusion matching conditions. Crit Care Med 2003, 31(2):543-551.
    • (2003) Crit Care Med , vol.31 , Issue.2 , pp. 543-551
    • Gama de Abreu, M.1    Winkler, T.2    Pahlitzsch, T.3
  • 30
    • 0742287108 scopus 로고    scopus 로고
    • 2 rebreathing techniques for cardiac output asessment in critically ill patients during assisted ventilation
    • 2 rebreathing techniques for cardiac output asessment in critically ill patients during assisted ventilation. Intensive Care Med 2004, 30(1):82-87.
    • (2004) Intensive Care Med , vol.30 , Issue.1 , pp. 82-87
    • Rocco, M.1    Spadetta, G.2    Morelli, A.3
  • 31
    • 9244249223 scopus 로고    scopus 로고
    • An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children
    • Levy R.J., Chiavacci R.M., Nicolson S.C., et al. An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children. Anesth Analg 2004, 99(6):1642-1647.
    • (2004) Anesth Analg , vol.99 , Issue.6 , pp. 1642-1647
    • Levy, R.J.1    Chiavacci, R.M.2    Nicolson, S.C.3
  • 32
    • 33646893666 scopus 로고    scopus 로고
    • Evaluation of noninvasive cardiac output in mechanically ventilated children
    • Botte A., Leclerc F., Riou Y., et al. Evaluation of noninvasive cardiac output in mechanically ventilated children. Pediatr Crit Care Med 2006, 7(3):231-236.
    • (2006) Pediatr Crit Care Med , vol.7 , Issue.3 , pp. 231-236
    • Botte, A.1    Leclerc, F.2    Riou, Y.3
  • 33
    • 57849150837 scopus 로고    scopus 로고
    • Comparison of three kinds of less invasive cardiac output measuring systems in aged patients
    • [in Japanese]
    • Yoshie K. Comparison of three kinds of less invasive cardiac output measuring systems in aged patients. Masui 2008, 57(12):1485-1493. [in Japanese].
    • (2008) Masui , vol.57 , Issue.12 , pp. 1485-1493
    • Yoshie, K.1
  • 34
    • 35948951555 scopus 로고    scopus 로고
    • Comparision of cardiac output measurements between NICO and the pulmonary artery catherter during repeat surgery for total hip replacement
    • Gueret G., Kiss G., Khaldi S., et al. Comparision of cardiac output measurements between NICO and the pulmonary artery catherter during repeat surgery for total hip replacement. Eur J Anaesthesiol 2007, 24(12):1028-1033.
    • (2007) Eur J Anaesthesiol , vol.24 , Issue.12 , pp. 1028-1033
    • Gueret, G.1    Kiss, G.2    Khaldi, S.3
  • 35
    • 19844376580 scopus 로고    scopus 로고
    • Minimally invasive optimization of organ donor resuscitation: case reports
    • de la Torre A.N., Fisher A., Wilson D.J., et al. Minimally invasive optimization of organ donor resuscitation: case reports. Prog Transplant 2005, 15(1):27-32.
    • (2005) Prog Transplant , vol.15 , Issue.1 , pp. 27-32
    • de la Torre, A.N.1    Fisher, A.2    Wilson, D.J.3
  • 36
    • 0034351171 scopus 로고    scopus 로고
    • 2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output
    • 2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output. J Clin Monit Comput 2000, 16(5-6):361-374.
    • (2000) J Clin Monit Comput , vol.16 , Issue.5-6 , pp. 361-374
    • Haryadi, D.G.1    Orr, J.A.2    Kuck, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.