-
1
-
-
33751109052
-
Hemodynamic monitoring over the past 10 years
-
Pinsky MR. Hemodynamic monitoring over the past 10 years. Crit Care 10:117, 2006
-
(2006)
Crit Care
, vol.10
, pp. 117
-
-
Pinsky, M.R.1
-
2
-
-
9544228424
-
The effectiveness of right heart catheterization in the initial care of critically ill patients
-
DOI 10.1001/jama.276.11.889
-
Connors AF Jr, Speroff T, Dawson NV, et al: The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 276:889-897, 1996 (Pubitemid 26301608)
-
(1996)
Journal of the American Medical Association
, vol.276
, Issue.11
, pp. 889-897
-
-
Connors Jr., A.F.1
Speroff, T.2
Dawson, N.V.3
Thomas, C.4
Harrell Jr., F.E.5
Wagner, D.6
Desbiens, N.7
Goldman, L.8
Wu, A.W.9
Califf, R.M.10
Fulkerson Jr., W.J.11
Vidaillet, H.12
Broste, S.13
Bellamy, P.14
Lynn, J.15
Knaus, W.A.16
-
3
-
-
0037413466
-
A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
-
DOI 10.1056/NEJMoa021108
-
Sandham JD, Hull RD, Brant RF, et al: A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 348:5-14, 2003 (Pubitemid 36026341)
-
(2003)
New England Journal of Medicine
, vol.348
, Issue.1
, pp. 5-14
-
-
Sandham, J.D.1
Hull, R.D.2
Frederick, B.R.3
Knox, L.4
Pineo, G.F.5
Doig, C.J.6
Laporta, D.P.7
Viner, S.8
Passerini, L.9
Devitt, H.10
Kirby, A.11
Jacka, M.12
-
4
-
-
34249013929
-
The pulmonary artery catheter: The tool versus treatments based on the tool
-
Takala J: The pulmonary artery catheter: the tool versus treatments based on the tool. Crit Care 10:162, 2006
-
(2006)
Crit Care
, vol.10
, pp. 162
-
-
Takala, J.1
-
6
-
-
26944486636
-
Noninvasive techniques for measurements of cardiac output
-
DOI 10.1097/01.ccx.0000176698.51456.5a
-
Cholley BP, Payen D: Non-invasive techniques for measurements of cardiac output. Curr Opin Crit Care 11:424-429, 2005 (Pubitemid 41482697)
-
(2005)
Current Opinion in Critical Care
, vol.11
, Issue.5
, pp. 424-429
-
-
Cholley, B.P.1
Payen, D.2
-
7
-
-
77950020487
-
Cardiac index validation using the pressure recording analytic method in unstable patients
-
Zangrillo A, Maj G, Monaco F, et al: Cardiac index validation using the pressure recording analytic method in unstable patients. J Cardiothorac Vasc Anesth 24:265-269, 2010
-
(2010)
J Cardiothorac Vasc Anesth
, vol.24
, pp. 265-269
-
-
Zangrillo, A.1
Maj, G.2
Monaco, F.3
-
8
-
-
0023786403
-
Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method
-
Schwid HA: Frequency response evaluation of radial artery catheter-manometer systems: sinusoidal frequency analysis versus flush method. J Clin Monit 4:181-185, 1988
-
(1988)
J Clin Monit
, vol.4
, pp. 181-185
-
-
Schwid, H.A.1
-
9
-
-
66849095760
-
Cardiac output by arterial pulse contour: Reliability under hemodynamic derangements
-
Romagnoli S, Romano SM, Bevilacqua S, et al: Cardiac output by arterial pulse contour: reliability under hemodynamic derangements. Interact Cardiovasc Thorac Surg 8:642-646, 2009
-
(2009)
Interact Cardiovasc Thorac Surg
, vol.8
, pp. 642-646
-
-
Romagnoli, S.1
Romano, S.M.2
Bevilacqua, S.3
-
10
-
-
0036342701
-
Assessment of cardiac output from systemic arterial pressure in humans
-
Romano SM, Pistolesi M: Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 30:1834-1841, 2002
-
(2002)
Crit Care Med
, vol.30
, pp. 1834-1841
-
-
Romano, S.M.1
Pistolesi, M.2
-
11
-
-
0002917589
-
Physical principles of circulatory phenomena: The physical equilibria of the heart and blood vessels
-
Hamilton WF (ed): Washington, DC, American Physiological Society
-
Burton AC: Physical principles of circulatory phenomena: The physical equilibria of the heart and blood vessels, in Hamilton WF (ed): Handbook of Physiology (vol 1). Washington, DC, American Physiological Society, 1961, pp 85-106
-
(1961)
Handbook of Physiology
, vol.1
, pp. 85-106
-
-
Burton, A.C.1
-
12
-
-
34548046282
-
The changing face of postoperative atrial fibrillation prevention: A review of current medical therapy
-
DOI 10.1097/CRD.0b013e31813e62bb, PII 0004541520070900000003
-
Mayson SE, Greenspon AJ, Adams S: The changing face of postoperative atrial fibrillation prevention: A review of current medical therapy. Cardiol Rev 15:231-241, 2007 (Pubitemid 47282032)
-
(2007)
Cardiology in Review
, vol.15
, Issue.5
, pp. 231-241
-
-
Mayson, S.E.1
Greenspon, A.J.2
Adams, S.3
DeCaro, M.V.4
Sheth, M.5
Weitz, H.H.6
Whellan, D.J.7
-
13
-
-
4143134234
-
Cardiac output monitoring by pressure recording analytical method in cardiac surgery
-
DOI 10.1016/j.ejcts.2004.05.025, PII S1010794004003963
-
Giomarelli P, Biagioli B, Scolletta S: Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg 26:515-520, 2004 (Pubitemid 39091989)
-
(2004)
European Journal of Cardio-thoracic Surgery
, vol.26
, Issue.3
, pp. 515-520
-
-
Giomarelli, P.1
Biagioli, B.2
Scolletta, S.3
-
14
-
-
34447523529
-
Comparison of cardiac output in OPCAB: Bolus thermodilution technique versus pulse contour analysis
-
Sujatha P, Mehta Y, Dhar A, et al: Comparison of cardiac output in OPCAB: Bolus thermodilution technique versus pulse contour analysis. Ann Card Anaesth 9:44-48, 2006
-
(2006)
Ann Card Anaesth
, vol.9
, pp. 44-48
-
-
Sujatha, P.1
Mehta, Y.2
Dhar, A.3
-
15
-
-
15944386360
-
Precision of bolus thermodilution cardiac output measurements in patients with atrial fibrillation
-
DOI 10.1111/j.1399-6576.2005.00613.x
-
Ostergaard M, Nilsson LB, Nilsson JC, et al: Precision of bolus thermodilution cardiac output measurements in patients with atrial fibrillation. Acta Anaesthesiol Scand 49:366-372, 2005 (Pubitemid 40432531)
-
(2005)
Acta Anaesthesiologica Scandinavica
, vol.49
, Issue.3
, pp. 366-372
-
-
Ostergaard, M.1
Nilsson, L.B.2
Nilsson, J.C.3
Rasmussen, J.P.4
Berthelsen, P.G.5
|