1
-
-
9544228424
-
The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators
-
10.1001/jama.276.11.889, 8782638
-
Connors AF, Speroff T, Dawson NV, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996, 276:889-897. 10.1001/jama.276.11.889, 8782638.
-
(1996)
JAMA
, vol.276
, pp. 889-897
-
-
Connors, A.F.1
Speroff, T.2
Dawson, N.V.3
-
2
-
-
85047278004
-
An evaluation of the clinical and cost-effectiveness of pulmonary artery catheters in patient management in intensive care: a systematic review and a randomised controlled trial
-
Harvey S, Stevens K, Harrison D, et al. An evaluation of the clinical and cost-effectiveness of pulmonary artery catheters in patient management in intensive care: a systematic review and a randomised controlled trial. Health Technol Assess 2006, 10:1-133.
-
(2006)
Health Technol Assess
, vol.10
, pp. 1-133
-
-
Harvey, S.1
Stevens, K.2
Harrison, D.3
-
3
-
-
77949885347
-
Clinical review: Goal-directed therapy in high risk surgical patients
-
10.1186/cc8039, 2784362, 19863764
-
Lees N, Hamilton M, Rhodes A. Clinical review: Goal-directed therapy in high risk surgical patients. Crit Care 2009, 13:231. 10.1186/cc8039, 2784362, 19863764.
-
(2009)
Crit Care
, vol.13
, pp. 231
-
-
Lees, N.1
Hamilton, M.2
Rhodes, A.3
-
4
-
-
68949178454
-
A systems approach to the early recognition and rapid administration of best practice therapy in sepsis and septic shock
-
10.1097/MCC.0b013e32832e3825, 19561493
-
Funk D, Sebat F, Kumar A. A systems approach to the early recognition and rapid administration of best practice therapy in sepsis and septic shock. Curr Opin Crit Care 2009, 15:301-307. 10.1097/MCC.0b013e32832e3825, 19561493.
-
(2009)
Curr Opin Crit Care
, vol.15
, pp. 301-307
-
-
Funk, D.1
Sebat, F.2
Kumar, A.3
-
5
-
-
23444461703
-
Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial
-
10.1016/S0140-6736(05)67061-4, 16084255
-
Harvey S, Harrison DA, Singer M, et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005, 366:472-477. 10.1016/S0140-6736(05)67061-4, 16084255.
-
(2005)
Lancet
, vol.366
, pp. 472-477
-
-
Harvey, S.1
Harrison, D.A.2
Singer, M.3
-
6
-
-
0027447134
-
Errors in the measurement of cardiac output by thermodilution
-
10.1007/BF03011312, 8443853
-
Nishikawa T, Dohi S. Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993, 40:142-153. 10.1007/BF03011312, 8443853.
-
(1993)
Can J Anaesth
, vol.40
, pp. 142-153
-
-
Nishikawa, T.1
Dohi, S.2
-
7
-
-
0032435617
-
Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes
-
10.1097/00000542-199812000-00047, 9856744
-
Aranda M, Mihm FG, Garrett S, Mihm MN, Pearl RG. Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes. Anesthesiology 1998, 89:1592-1595. 10.1097/00000542-199812000-00047, 9856744.
-
(1998)
Anesthesiology
, vol.89
, pp. 1592-1595
-
-
Aranda, M.1
Mihm, F.G.2
Garrett, S.3
Mihm, M.N.4
Pearl, R.G.5
-
8
-
-
1842833460
-
Evaluation of a new continuous cardiac output monitor in off-pump coronary artery surgery
-
10.1111/j.1365-2044.2004.03668.x, 15023110
-
Leather HA, Vuylsteke A, Bert C, et al. Evaluation of a new continuous cardiac output monitor in off-pump coronary artery surgery. Anaesthesia 2004, 59:385-389. 10.1111/j.1365-2044.2004.03668.x, 15023110.
-
(2004)
Anaesthesia
, vol.59
, pp. 385-389
-
-
Leather, H.A.1
Vuylsteke, A.2
Bert, C.3
-
9
-
-
38549151697
-
Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
-
10.1097/01.CCM.OB013E318161FEC4, 18091547
-
Hamzaoui O, Monnet X, Richard C, et al. Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008, 36:434-440. 10.1097/01.CCM.OB013E318161FEC4, 18091547.
-
(2008)
Crit Care Med
, vol.36
, pp. 434-440
-
-
Hamzaoui, O.1
Monnet, X.2
Richard, C.3
-
10
-
-
34548266524
-
Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
-
10.1093/bja/aem188, 17631509
-
Button D, Weibel L, Reuthebuch O, et al. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007, 99:329-336. 10.1093/bja/aem188, 17631509.
-
(2007)
Br J Anaesth
, vol.99
, pp. 329-336
-
-
Button, D.1
Weibel, L.2
Reuthebuch, O.3
-
11
-
-
0142149221
-
Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation
-
10.1007/BF03018714, 12944446
-
Della Rocca G, Costa MG, Coccia C, et al. Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation. Can J Anaesth 2003, 50:707-711. 10.1007/BF03018714, 12944446.
-
(2003)
Can J Anaesth
, vol.50
, pp. 707-711
-
-
Della Rocca, G.1
Costa, M.G.2
Coccia, C.3
-
12
-
-
41549163951
-
A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients
-
10.1186/1471-2253-8-3, 2275227, 18282275
-
Cecconi M, Fawcett J, Grounds RM, Rhodes A. A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients. BMC Anesthesiol 2008, 8:3. 10.1186/1471-2253-8-3, 2275227, 18282275.
-
(2008)
BMC Anesthesiol
, vol.8
, pp. 3
-
-
Cecconi, M.1
Fawcett, J.2
Grounds, R.M.3
Rhodes, A.4
-
13
-
-
60449102439
-
Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique
-
10.1007/s00134-008-1292-4, 18802681
-
Cecconi M, Dawson D, Grounds RM, Rhodes A. Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique. Intensive Care Med 2009, 35:498-504. 10.1007/s00134-008-1292-4, 18802681.
-
(2009)
Intensive Care Med
, vol.35
, pp. 498-504
-
-
Cecconi, M.1
Dawson, D.2
Grounds, R.M.3
Rhodes, A.4
-
14
-
-
33845321475
-
Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]
-
10.1186/cc3887, 1414018, 16356219
-
Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care 2005, 9:R687-R693. 10.1186/cc3887, 1414018, 16356219.
-
(2005)
Crit Care
, vol.9
-
-
Pearse, R.1
Dawson, D.2
Fawcett, J.3
Rhodes, A.4
Grounds, R.M.5
Bennett, E.D.6
-
15
-
-
65649112876
-
Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis
-
10.1053/j.jvca.2009.03.003, 19464625
-
Mayer J, Boldt J, Poland R, Peterson A, Manecke GR. Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth 2009, 23:401-406. 10.1053/j.jvca.2009.03.003, 19464625.
-
(2009)
J Cardiothorac Vasc Anesth
, vol.23
, pp. 401-406
-
-
Mayer, J.1
Boldt, J.2
Poland, R.3
Peterson, A.4
Manecke, G.R.5
-
16
-
-
62849098504
-
Assessment of cardiac output changes using a modified FloTrac/Vigileo algorithm in cardiac surgery patients
-
10.1186/cc7739, 2689464, 19261180
-
Senn A, Button D, Zollinger A, Hofer CK. Assessment of cardiac output changes using a modified FloTrac/Vigileo algorithm in cardiac surgery patients. Crit Care 2009, 13:R32. 10.1186/cc7739, 2689464, 19261180.
-
(2009)
Crit Care
, vol.13
-
-
Senn, A.1
Button, D.2
Zollinger, A.3
Hofer, C.K.4
-
17
-
-
77957355322
-
Pitfalls in haemodynamic monitoring based on the arterial pressure waveform
-
10.1186/cc8845, 2887100, 20236463
-
Camporota L, Beale R. Pitfalls in haemodynamic monitoring based on the arterial pressure waveform. Crit Care 2010, 14:124. 10.1186/cc8845, 2887100, 20236463.
-
(2010)
Crit Care
, vol.14
, pp. 124
-
-
Camporota, L.1
Beale, R.2
-
18
-
-
77953960618
-
Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial
-
10.1186/cc8875, 2875533, 20156348
-
Mayer J, Boldt J, Mengistu AM, Rohm KD, Suttner S. Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial. Crit Care 2010, 14:R18. 10.1186/cc8875, 2875533, 20156348.
-
(2010)
Crit Care
, vol.14
-
-
Mayer, J.1
Boldt, J.2
Mengistu, A.M.3
Rohm, K.D.4
Suttner, S.5
-
19
-
-
23844520689
-
Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states
-
10.1093/bja/aei154, 15894561
-
Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P. Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaesth 2005, 95:159-165. 10.1093/bja/aei154, 15894561.
-
(2005)
Br J Anaesth
, vol.95
, pp. 159-165
-
-
Scolletta, S.1
Romano, S.M.2
Biagioli, B.3
Capannini, G.4
Giomarelli, P.5
-
20
-
-
4143134234
-
Cardiac output monitoring by pressure recording analytical method in cardiac surgery
-
10.1016/j.ejcts.2004.05.025, 15302045
-
Giomarelli P, Biagioli B, Scolletta S. Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg 2004, 26:515-520. 10.1016/j.ejcts.2004.05.025, 15302045.
-
(2004)
Eur J Cardiothorac Surg
, vol.26
, pp. 515-520
-
-
Giomarelli, P.1
Biagioli, B.2
Scolletta, S.3
-
21
-
-
70449646306
-
Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
-
10.1186/1471-2253-9-6, 2766368, 19821993
-
Stover JF, Stocker R, Lenherr R, et al. Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients. BMC Anesthesiol 2009, 9:6. 10.1186/1471-2253-9-6, 2766368, 19821993.
-
(2009)
BMC Anesthesiol
, vol.9
, pp. 6
-
-
Stover, J.F.1
Stocker, R.2
Lenherr, R.3
-
22
-
-
0031946626
-
Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients
-
10.1007/s001340050578, 9609413
-
Lefrant JY, Bruelle P, Aya AG, et al. Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 1998, 24:347-352. 10.1007/s001340050578, 9609413.
-
(1998)
Intensive Care Med
, vol.24
, pp. 347-352
-
-
Lefrant, J.Y.1
Bruelle, P.2
Aya, A.G.3
-
23
-
-
0031871297
-
Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler
-
Valtier B, Cholley BP, Belot JP, et al. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med 1998, 158:77-83.
-
(1998)
Am J Respir Crit Care Med
, vol.158
, pp. 77-83
-
-
Valtier, B.1
Cholley, B.P.2
Belot, J.P.3
-
24
-
-
36849055073
-
Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery
-
10.1111/j.1365-2044.2007.05233.x, 18086070
-
Abbas SM, Hill AG. Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia 2008, 63:44-51. 10.1111/j.1365-2044.2007.05233.x, 18086070.
-
(2008)
Anaesthesia
, vol.63
, pp. 44-51
-
-
Abbas, S.M.1
Hill, A.G.2
-
25
-
-
33846979129
-
Measurement of cardiac output with a non-invasive continuous wave Doppler device versus the pulmonary artery catheter: a comparative study
-
Chan JS, Segara D, Nair P. Measurement of cardiac output with a non-invasive continuous wave Doppler device versus the pulmonary artery catheter: a comparative study. Crit Care Resusc 2006, 8:309-314.
-
(2006)
Crit Care Resusc
, vol.8
, pp. 309-314
-
-
Chan, J.S.1
Segara, D.2
Nair, P.3
-
26
-
-
71749098943
-
Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter
-
10.1093/bja/aep296, 19864307
-
Thom O, Taylor DM, Wolfe RE, et al. Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter. Br J Anaesth 2009, 103:800-804. 10.1093/bja/aep296, 19864307.
-
(2009)
Br J Anaesth
, vol.103
, pp. 800-804
-
-
Thom, O.1
Taylor, D.M.2
Wolfe, R.E.3
-
27
-
-
33749078184
-
Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter
-
10.1017/S0265021506000573, 16953944
-
Gueret G, Kiss G, Rossignol B, et al. Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter. Eur J Anaesthesiol 2006, 23:848-854. 10.1017/S0265021506000573, 16953944.
-
(2006)
Eur J Anaesthesiol
, vol.23
, pp. 848-854
-
-
Gueret, G.1
Kiss, G.2
Rossignol, B.3
-
28
-
-
0037381750
-
Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present
-
10.1097/00000542-200304000-00007, 12657842
-
Tachibana K, Imanaka H, Takeuchi M, Takauchi Y, Miyano H, Nishimura M. Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present. Anesthesiology 2003, 98:830-837. 10.1097/00000542-200304000-00007, 12657842.
-
(2003)
Anesthesiology
, vol.98
, pp. 830-837
-
-
Tachibana, K.1
Imanaka, H.2
Takeuchi, M.3
Takauchi, Y.4
Miyano, H.5
Nishimura, M.6
-
29
-
-
2442601264
-
Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique
-
10.1111/j.1399-6576.2004.00371.x, 15101865
-
Hofer CK, Buhlmann S, Klaghofer R, Genoni M, Zollinger A. Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique. Acta Anaesthesiol Scand 2004, 48:653-657. 10.1111/j.1399-6576.2004.00371.x, 15101865.
-
(2004)
Acta Anaesthesiol Scand
, vol.48
, pp. 653-657
-
-
Hofer, C.K.1
Buhlmann, S.2
Klaghofer, R.3
Genoni, M.4
Zollinger, A.5
-
30
-
-
77957693779
-
Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients
-
Ball TR, Culp BC, Patel V, et al. Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients. J Cardiothorac Vasc 2010, 24:762-766.
-
(2010)
J Cardiothorac Vasc
, vol.24
, pp. 762-766
-
-
Ball, T.R.1
Culp, B.C.2
Patel, V.3
-
31
-
-
45849152599
-
Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: comparison with thermodilution method
-
10.1007/s10877-008-9119-y, 18418719
-
Gujjar AR, Muralidhar K, Banakal S, et al. Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: comparison with thermodilution method. J Clin Monit Comput 2008, 22:175-180. 10.1007/s10877-008-9119-y, 18418719.
-
(2008)
J Clin Monit Comput
, vol.22
, pp. 175-180
-
-
Gujjar, A.R.1
Muralidhar, K.2
Banakal, S.3
-
32
-
-
34447131664
-
Noninvasive cardiac output monitoring (NICOM): a clinical validation
-
10.1007/s00134-007-0640-0, 17458538
-
Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 2007, 33:1191-1194. 10.1007/s00134-007-0640-0, 17458538.
-
(2007)
Intensive Care Med
, vol.33
, pp. 1191-1194
-
-
Squara, P.1
Denjean, D.2
Estagnasie, P.3
Brusset, A.4
Dib, J.C.5
Dubois, C.6
-
33
-
-
41949125848
-
Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique
-
10.1007/s10877-008-9112-5, 18340540
-
Raval NY, Squara P, Cleman M, Yalamanchili K, Winklmaier M, Burkhoff D. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 2008, 22:113-119. 10.1007/s10877-008-9112-5, 18340540.
-
(2008)
J Clin Monit Comput
, vol.22
, pp. 113-119
-
-
Raval, N.Y.1
Squara, P.2
Cleman, M.3
Yalamanchili, K.4
Winklmaier, M.5
Burkhoff, D.6
-
34
-
-
0031892916
-
Volume replacement strategies on intensive care units: results from a postal survey
-
10.1007/s001340050536, 9539072
-
Boldt J, Lenz M, Kumle B, Papsdorf M. Volume replacement strategies on intensive care units: results from a postal survey. Intensive Care Med 1998, 24:147-151. 10.1007/s001340050536, 9539072.
-
(1998)
Intensive Care Med
, vol.24
, pp. 147-151
-
-
Boldt, J.1
Lenz, M.2
Kumle, B.3
Papsdorf, M.4
-
35
-
-
19944420853
-
Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography
-
10.1093/bja/aei123, 15790674
-
Hofer CK, Furrer L, Matter-Ensner S, et al. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth 2005, 94:748-755. 10.1093/bja/aei123, 15790674.
-
(2005)
Br J Anaesth
, vol.94
, pp. 748-755
-
-
Hofer, C.K.1
Furrer, L.2
Matter-Ensner, S.3
-
36
-
-
12144287425
-
Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
-
10.1097/01.CCM.0000114996.68110.C9, 15090949
-
Kumar A, Anel R, Bunnell E, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004, 32:691-699. 10.1097/01.CCM.0000114996.68110.C9, 15090949.
-
(2004)
Crit Care Med
, vol.32
, pp. 691-699
-
-
Kumar, A.1
Anel, R.2
Bunnell, E.3
-
37
-
-
33846323221
-
Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients
-
10.1007/s00134-006-0404-2, 17119923
-
Goepfert MS, Reuter DA, Akyol D, et al. Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med 2007, 33:96-103. 10.1007/s00134-006-0404-2, 17119923.
-
(2007)
Intensive Care Med
, vol.33
, pp. 96-103
-
-
Goepfert, M.S.1
Reuter, D.A.2
Akyol, D.3
-
38
-
-
0036929495
-
Prognostic value of extravascular lung water in critically ill patients
-
10.1378/chest.122.6.2080, 12475851
-
Sakka SG, Klein M, Reinhart K, Meier-Hellmann A. Prognostic value of extravascular lung water in critically ill patients. Chest 2002, 122:2080-2086. 10.1378/chest.122.6.2080, 12475851.
-
(2002)
Chest
, vol.122
, pp. 2080-2086
-
-
Sakka, S.G.1
Klein, M.2
Reinhart, K.3
Meier-Hellmann, A.4
-
39
-
-
69349089330
-
Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature
-
10.1097/CCM.0b013e3181a590da, 19602972
-
Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009, 37:2642-2647. 10.1097/CCM.0b013e3181a590da, 19602972.
-
(2009)
Crit Care Med
, vol.37
, pp. 2642-2647
-
-
Marik, P.E.1
Cavallazzi, R.2
Vasu, T.3
Hirani, A.4
-
40
-
-
47549096309
-
Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
-
10.1378/chest.07-2331, 18628220
-
Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008, 134:172-178. 10.1378/chest.07-2331, 18628220.
-
(2008)
Chest
, vol.134
, pp. 172-178
-
-
Marik, P.E.1
Baram, M.2
Vahid, B.3
-
41
-
-
43349086860
-
Passive leg raising
-
10.1007/s00134-008-0994-y, 18214429
-
Monnet X, Teboul JL. Passive leg raising. Intensive Care Med 2008, 34:659-663. 10.1007/s00134-008-0994-y, 18214429.
-
(2008)
Intensive Care Med
, vol.34
, pp. 659-663
-
-
Monnet, X.1
Teboul, J.L.2
-
42
-
-
33748552963
-
Venous oximetry
-
10.1097/01.ccx.0000224872.09077.dc, 16672787
-
Marx G, Reinhart K. Venous oximetry. Curr Opin Crit Care 2006, 12:263-268. 10.1097/01.ccx.0000224872.09077.dc, 16672787.
-
(2006)
Curr Opin Crit Care
, vol.12
, pp. 263-268
-
-
Marx, G.1
Reinhart, K.2
-
43
-
-
0035829842
-
Early goal-directed therapy in the treatment of severe sepsis and septic shock
-
10.1056/NEJMoa010307, 11794169
-
Rivers E, Nguyen B, Havstad S, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001, 345:1368-1377. 10.1056/NEJMoa010307, 11794169.
-
(2001)
N Engl J Med
, vol.345
, pp. 1368-1377
-
-
Rivers, E.1
Nguyen, B.2
Havstad, S.3
-
44
-
-
23044442783
-
Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions
-
10.1097/00000542-200508000-00007, 16052106
-
Dueck MH, Klimek M, Appenrodt S, Weigand C, Boerner U. Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005, 103:249-257. 10.1097/00000542-200508000-00007, 16052106.
-
(2005)
Anesthesiology
, vol.103
, pp. 249-257
-
-
Dueck, M.H.1
Klimek, M.2
Appenrodt, S.3
Weigand, C.4
Boerner, U.5
|