메뉴 건너뛰기




Volumn , Issue , 2010, Pages 439-461

On-Line PAT Applications of Spectroscopy in the Pharmaceutical Industry

Author keywords

API drying time consuming and hazardous process; Biologics fermentation and freeze drying; Coating benefiting from on line spectroscopic monitoring for understanding and control; Crystallization constituent of chemical reaction; Granulation preparing drug substance and excipient particles for compression; Hot melt extrusion (HME) preparation of drug delivery systems; Nanomilling effective processing option to overcome insolubility; On line PAT applications of spectroscopy in pharmaceutical industry; Powder blending uniformity at appropriate mass scale; Reaction monitoring process monitoring and control of API production

Indexed keywords


EID: 79958819972     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9780470689592.ch13     Document Type: Chapter
Times cited : (8)

References (138)
  • 1
    • 0005248386 scopus 로고    scopus 로고
    • US Food and Drug Administration
    • Pharmaceutical cGMPS for the 21st Century-A Risk-Based Approach: Second Progress Report and Implementation Plan, available, accessed 27 November 2009
    • US Food and Drug Administration , Pharmaceutical cGMPS for the 21st Century !- A Risk-Based Approach: Second Progress Report and Implementation Plan, 2003, available http://www.fda.gov/cder/gmp/2ndProgressRept_Plan. htm accessed 27 November 2009.
    • (2003)
  • 2
    • 2542465496 scopus 로고    scopus 로고
    • US Food and Drug Administration
    • PAT-A Framework for Innovative Pharmaceutical Manufacturing and Quality Assurance, available, accessed 27 November 2009
    • US Food and Drug Administration , PAT-A Framework for Innovative Pharmaceutical Manufacturing and Quality Assurance, 2004, available http://www.fda.gov/CDER/GUIDANCE/6419fnl.htm accessed 27 November 2009.
    • (2004)
  • 3
    • 54049101634 scopus 로고    scopus 로고
    • FDA backs PAT to help solve manufacturing woes: process analytical technology is a key part of Agency ' s plan for the 21st century
    • available, accessed 27 November 2009
    • L. Dunlap , FDA backs PAT to help solve manufacturing woes: process analytical technology is a key part of Agency ' s plan for the 21st century , Genetic Engineering & Biotechnology News , 28 ( 16 ), ( 2008 ), available http:// www.genengnews.com/articles/chitem.aspx?aid=2596 & chid=3 accessed 27 November 2009.
    • (2008) Genetic Engineering & Biotechnology News , vol.28 , Issue.16
    • Dunlap, L.1
  • 4
    • 84886151228 scopus 로고    scopus 로고
    • Dissolution testing and metrological measurement of quality for solid oral dosage forms: USP applies metrological principles to the dissolution procedure alone and in collaborative studies to understand and minimize potential sources of variability
    • available, accessed 27 November 2009
    • R.G. Manning , S.Z. Wahab , W.E. Brown , W.W. Hauck , S. Schuber and R.L. Williams , Dissolution testing and metrological measurement of quality for solid oral dosage forms: USP applies metrological principles to the dissolution procedure alone and in collaborative studies to understand and minimize potential sources of variability, 2007, available http://pharmtech.fi ndpharma.com/pharmtech/InsideUSP/article/detail/423552 accessed 27 November 2009.
    • (2007)
    • Manning, R.G.1    Wahab, S.Z.2    Brown, W.E.3    Hauck, W.W.4    Schuber, S.5    Williams, R.L.6
  • 5
    • 11944250428 scopus 로고
    • Process analytical-chemistry-an industrial perspective
    • M.T. Riebe , D.J. Eustace , Process analytical-chemistry-an industrial perspective , Anal. Chem. , 62 ( 2 ), A65-A71 ( 1990 ).
    • (1990) Anal. Chem. , , vol.62 , Issue.2
    • Riebe, M.T.1    Eustace, D.J.2
  • 11
    • 0038382864 scopus 로고    scopus 로고
    • Process analytical chemistry
    • J. Workman , M. Koch and D. Veltkamp , Process analytical chemistry , Anal. Chem. , 75 ( 12 ), 2859-2876 ( 2003 ).
    • (2003) Anal. Chem. , , vol.75 , Issue.12 , pp. 2859-2876
    • Workman, J.1    Koch, M.2    Veltkamp, D.3
  • 12
    • 20744458897 scopus 로고    scopus 로고
    • Process analytical chemistry
    • J. Workman , Jr ., M. Koch and D. Veltkamp , Process analytical chemistry , Anal. Chem. , 77 ( 9 ), 3789-3806 ( 2005 ).
    • (2005) Anal. Chem. , , vol.77 , Issue.9 , pp. 3789-3806
    • Workman, J.1    Koch, M.2    Veltkamp, D.3
  • 13
    • 34347207960 scopus 로고    scopus 로고
    • Process analytical chemistry
    • J. Workman , M. Koch and D. Veltkamp , Process analytical chemistry , Anal. Chem. , 79 ( 12 ), 4345-4363 ( 2007 ).
    • (2007) Anal. Chem. , , vol.79 , Issue.12 , pp. 4345-4363
    • Workman, J.1    Koch, M.2    Veltkamp, D.3
  • 14
    • 0029346631 scopus 로고
    • Quantitative monitoring of an epoxidation process by Fourier-Transform infrared spectroscopy
    • Z.H. Ge , R. Thompson , S. Cooper , D. Ellison and P. Tway , Quantitative monitoring of an epoxidation process by Fourier-Transform infrared spectroscopy , Process Contr. Qual. , 7 ( 1 ), 3-12 ( 1995 ).
    • (1995) Process Contr. Qual. , vol.7 , Issue.1 , pp. 3-12
    • Ge, Z.H.1    Thompson, R.2    Cooper, S.3    Ellison, D.4    Tway, P.5
  • 15
    • 0036533103 scopus 로고    scopus 로고
    • Employment of on-line FT-IR spectroscopy to monitor the deprotection of a 9-fl uorenylmethyl protected carboxylic acid peptide conjugate of doxorubicin
    • M. Cameron , G.X. Zhou , M.B. Hicks , et al. , Employment of on-line FT-IR spectroscopy to monitor the deprotection of a 9-fl uorenylmethyl protected carboxylic acid peptide conjugate of doxorubicin , J. Pharm. Biomed. Anal. , 28 , 137-144 ( 2002 ).
    • (2002) J. Pharm. Biomed. Anal. , vol.28 , pp. 137-144
    • Cameron, M.1    Zhou, G.X.2    Hicks, M.B.3
  • 16
    • 0142231074 scopus 로고    scopus 로고
    • Study of lactol activation by trifl uoroacetic anhydride via in situ Fourier transform infrared spectroscopy
    • Y. Chen , G. Zhou , N. Brown , T. Wang and Z. Ge , Study of lactol activation by trifl uoroacetic anhydride via in situ Fourier transform infrared spectroscopy , Anal. Chim. Acta , 497 ( 1-2 ), 155-164 ( 2003 ).
    • (2003) Anal. Chim. Acta , , vol.497 , Issue.1-2 , pp. 155-164
    • Chen, Y.1    Zhou, G.2    Brown, N.3    Wang, T.4    Ge, Z.5
  • 17
    • 0034345204 scopus 로고    scopus 로고
    • On-line mid-ir spectroscopy as a real-time approach in monitoring hydrogenation reactions
    • D. Marziano , C.A. Sharp , P.J. Dunn , and P.A. Hailey , On-line mid-ir spectroscopy as a real-time approach in monitoring hydrogenation reactions , Org. Process Res. Dev. , 4 , 357-361 ( 2000 ).
    • (2000) Org. Process Res. Dev. , vol.4 , pp. 357-361
    • Marziano, D.1    Sharp, C.A.2    Dunn, P.J.3    Hailey, P.A.4
  • 18
    • 0033752068 scopus 로고    scopus 로고
    • Determination of the end point of a chemical synthesis process using on-line measured mid-infrared spectra
    • K. De Braekeleer , A. de Juan , F.C. Sanchez , P.A. Hailey , D.C.A. Sharp , P. Dunn and D.L. Massart , Determination of the end point of a chemical synthesis process using on-line measured mid-infrared spectra , Appl. Spectrosc. , 54 ( 4 ), 601-607 ( 2000 ).
    • (2000) Appl. Spectrosc. , , vol.54 , Issue.4 , pp. 601-607
    • De Braekeleer, K.1    de Juan, A.2    Sanchez, F.C.3    Hailey, P.A.4    Sharp, D.C.A.5    Dunn, P.6    Massart, D.L.7
  • 19
    • 0031699467 scopus 로고    scopus 로고
    • On-line determination of reaction completion in a closed-loop hydrogenator using NIR spectroscopy
    • W.W. Howard , S. Sekulic , M.J. Wheeler , et al. , On-line determination of reaction completion in a closed-loop hydrogenator using NIR spectroscopy , Appl. Spectrosc. , 52 ( 1 ), 17-21 ( 1998 ).
    • (1998) Appl. Spectrosc. , , vol.52 , Issue.1 , pp. 17-21
    • Howard, W.W.1    Sekulic, S.2    Wheeler, M.J.3
  • 20
    • 0013351607 scopus 로고    scopus 로고
    • On-line monitoring of the distillates of a solvent switch process by near-infrared spectroscopy
    • Z.H. Ge , B. Buchanan , J. Timmermans , D. De Tora , D. Ellison and J. Wyvratt , On-line monitoring of the distillates of a solvent switch process by near-infrared spectroscopy , Process Contr. Qual. , 11 ( 4 ), 277-287 ( 1999 ).
    • (1999) Process Contr. Qual. , , vol.11 , Issue.4 , pp. 277-287
    • Ge, Z.H.1    Buchanan, B.2    Timmermans, J.3    De Tora, D.4    Ellison, D.5    Wyvratt, J.6
  • 21
    • 0032807028 scopus 로고    scopus 로고
    • Real time quantitation of a chemical reaction by fi ber optic near-infrared spectroscopy
    • C. Coffey , B.E. Cooley and D.S. Walker , Real time quantitation of a chemical reaction by fi ber optic near-infrared spectroscopy , Anal. Chim. Acta , 395 ( 3 ), 335-341 ( 1999 ).
    • (1999) Anal. Chim. Acta , , vol.395 , Issue.3 , pp. 335-341
    • Coffey, C.1    . Cooley, B.2    Walker, D.S.3
  • 22
    • 0033678763 scopus 로고    scopus 로고
    • On-line monitoring and quantifi cation of a process reaction by near-infrared spectroscopy
    • Analyst
    • M. Blanco and D. Serrano , On-line monitoring and quantifi cation of a process reaction by near-infrared spectroscopy. Catalysed esterifi cation of butan-1-ol by acetic acid , Analyst , 125 , 2059-2064 ( 2000 ).
    • (2000) Catalysed esterifi cation of butan-1-ol by acetic acid , vol.125 , pp. 2059-2064
    • Blanco, M.1    Serrano, D.2
  • 23
    • 33645060732 scopus 로고    scopus 로고
    • Real-time end point monitoring and determination for a pharmaceutical salt formation process within in-line FT-IR spectroscopy
    • Z. Lin , L. Zhou , A. Mahajan , S. Song , T. Wang , Z. Ge and D. Ellison , Real-time end point monitoring and determination for a pharmaceutical salt formation process within in-line FT-IR spectroscopy , J. Pharm. Biomed. Anal. , 41 , 99-104 ( 2006 ).
    • (2006) J. Pharm. Biomed. Anal. , vol.41 , pp. 99-104
    • Lin, Z.1    Zhou, L.2    Mahajan, A.3    Song, S.4    Wang, T.5    Ge, Z.6    Ellison, D.7
  • 24
    • 0033580072 scopus 로고    scopus 로고
    • Fiber-optic UV/visible composition monitoring for process control of batch reactions
    • A.C. Quinn , P.J. Gemperline , B. Baker , M. Zhu and D.S. Walker , Fiber-optic UV/visible composition monitoring for process control of batch reactions , Chemom. Intell. Lab. Syst. , 45 , 199-214 ( 1999 )
    • (1999) Chemom. Intell. Lab. Syst. , vol.45 , pp. 199-214
    • Quinn, A.C.1    Gemperline, P.J.2    Baker, B.3    Zhu, M.4    Walker, D.S.5
  • 26
    • 3042593287 scopus 로고    scopus 로고
    • Monitoring and feedback control of supersaturation using ATR-FTIR to produce an active pharmaceutical ingredient of a desired crystal size
    • V. Liotta and V. Sabesan , Monitoring and feedback control of supersaturation using ATR-FTIR to produce an active pharmaceutical ingredient of a desired crystal size , Org. Process Res. Dev. , 8 , 488-494 ( 2004 ).
    • (2004) Org. Process Res. Dev. , vol.8 , pp. 488-494
    • Liotta, V.1    Sabesan, V.2
  • 27
    • 0035836446 scopus 로고    scopus 로고
    • On-line ATR-FTIR measurement of supersaturation during solution crystallization processes. Calibrations and applications on three solute/solvent systems
    • F. Lewiner , J.P. Klein , F. Puel and G. F é votte , On-line ATR-FTIR measurement of supersaturation during solution crystallization processes. Calibrations and applications on three solute/solvent systems , Chem. Eng. Sci. , 56 , 2069-2084 ( 2001 ).
    • (2001) Chem. Eng. Sci. , vol.56 , pp. 2069-2084
    • Lewiner, F.1    Klein, J.P.2    Puel, F.3    Févotte, G.4
  • 28
    • 0037173521 scopus 로고    scopus 로고
    • New perspectives for the on-line monitoring of pharmaceutical crystallization processes using in situ infrared spectroscopy
    • G. F é votte , New perspectives for the on-line monitoring of pharmaceutical crystallization processes using in situ infrared spectroscopy , Int. J. Pharm. , 241 , 263-278 ( 2002 ).
    • (2002) Int. J. Pharm. , vol.241 , pp. 263-278
    • Févotte, G.1
  • 29
    • 0012266055 scopus 로고    scopus 로고
    • Paracetamol crystallization using laser backscattering and ATR-FTIR spectroscopy: metastability
    • M. Fujiwara , P.S. Chow , D.L. Ma and R.D. Braatz , Paracetamol crystallization using laser backscattering and ATR-FTIR spectroscopy: metastability, agglomeration, and control , Cryst. Growth Des. , 2 ( 5 ), 363-370 ( 2002 ).
    • (2002) agglomeration, and control , Cryst. Growth Des. , , vol.2 , Issue.5 , pp. 363-370
    • Fujiwara, M.1    Chow, P.S.2    Ma, D.L.3    Braatz, R.D.4
  • 30
    • 19644362083 scopus 로고    scopus 로고
    • IR spectroscopy together with multivariate data analysis as a process analytical tool for in-line monitoring of crystallization process and solid-state analysis of crystalline product
    • K. Pöllänen , A. Häkkinen , S-P. Reinikinen , J. Rantanen , M. Karjalainen , M. Louhi-Kultanen and L. Nyström , IR spectroscopy together with multivariate data analysis as a process analytical tool for in-line monitoring of crystallization process and solid-state analysis of crystalline product , J. Pharm. Biomed. Anal. , 38 , 275-284 ( 2005 ).
    • (2005) J. Pharm. Biomed. Anal. , vol.38 , pp. 275-284
    • Pöllänen, K.1    Häkkinen, A.2    Reinikinen, S.-P.3    Rantanen, J.4    Karjalainen, M.5    Louhi-Kultanen, M.6    Nyström, L.7
  • 31
    • 0041392760 scopus 로고    scopus 로고
    • Process optimization of a complex pharmaceutical polymorphic system via in situ Raman spectroscopy
    • C. Starbuck , A. Spartalis , L. Wai , et al. , Process optimization of a complex pharmaceutical polymorphic system via in situ Raman spectroscopy , Cryst. Growth Des. , 2 ( 6 ), 515-522 ( 2002 ).
    • (2002) Cryst. Growth Des. , , vol.2 , Issue.6 , pp. 515-522
    • Starbuck, C.1    Spartalis, A.2    Wai, L.3
  • 32
    • 0030923768 scopus 로고    scopus 로고
    • Determination of end-points for polymorph conversions of crystalline organic compounds using on-line near-infrared
    • T. Norris , P.K. Aldridge and S.S. Sekulic , Determination of end-points for polymorph conversions of crystalline organic compounds using on-line near-infrared , Analyst , 122 ( 6 ), 549-552 ( 1997 ).
    • (1997) Analyst , , vol.122 , Issue.6 , pp. 549-552
    • Norris, T.1    Aldridge, P.K.2    Sekulic, S.S.3
  • 33
    • 33750920833 scopus 로고    scopus 로고
    • In-line measurement of a drug substance via near infrared spectroscopy to ensure a robust crystallization
    • G.X. Zhou , L. Crocker , J. Xu , J. Tabora and Z. Ge , In-line measurement of a drug substance via near infrared spectroscopy to ensure a robust crystallization , J. Pharm. Sci. , 95 ( 11 ), 2337-2347 ( 2006 ).
    • (2006) J. Pharm. Sci. , , vol.95 , Issue.11 , pp. 2337-2347
    • Zhou, G.X.1    Crocker, L.2    Xu, J.3    Tabora, J.4    Ge, Z.5
  • 35
    • 0031696444 scopus 로고    scopus 로고
    • Gas chromatography as a reference method for moisture determination by near-infrared spectroscopy
    • X. Zhou , P.A. Hines , K.C. White and M.W. Borer , Gas chromatography as a reference method for moisture determination by near-infrared spectroscopy , Anal. Chem. , 70 , 390-394 ( 1998 ).
    • (1998) Anal. Chem. , vol.70 , pp. 390-394
    • Zhou, X.1    Hines, P.A.2    White, K.C.3    Borer, M.W.4
  • 36
    • 0032103258 scopus 로고    scopus 로고
    • Moisture determination in hygroscopic drug substances by near infrared spectroscopy
    • X. Zhou , P.A. Hines , and M.W. Borer , Moisture determination in hygroscopic drug substances by near infrared spectroscopy , J. Pharm. Biomed. Anal. , 17 , 219-225 ( 1998 ).
    • (1998) J. Pharm. Biomed. Anal. , vol.17 , pp. 219-225
    • Zhou, X.1    Hines, P.A.2    Borer, M.W.3
  • 37
    • 0027765697 scopus 로고
    • Suitability of near-infrared methods for the determination of moisture in a freeze-dried injection product containing different amounts of the active ingredient
    • I.R. Last and K.A. Prebble , Suitability of near-infrared methods for the determination of moisture in a freeze-dried injection product containing different amounts of the active ingredient , J. Pharm. Biomed. Anal. , 11 ( 11/12 ), 1071-1076 ( 1993 ).
    • (1993) J. Pharm. Biomed. Anal. , , vol.11 , Issue.11-12 , pp. 1071-1076
    • Last, I.R.1    Prebble, K.A.2
  • 38
    • 0027765698 scopus 로고
    • Some applications of near-infrared refl ectance analysis in the pharmaceutical industry
    • B.F. MacDonald and K.A. Prebble , Some applications of near-infrared refl ectance analysis in the pharmaceutical industry , J. Pharm. Biomed. Anal. , 11 ( 11/12 ), 1077-1085 ( 1993 ).
    • (1993) J. Pharm. Biomed. Anal. , , vol.11 , Issue.11-12 , pp. 1077-1085
    • MacDonald, B.F.1    Prebble, K.A.2
  • 39
    • 0037370185 scopus 로고    scopus 로고
    • In situ moisture determination of a cytotoxic compound during process optimization
    • M.B. Hicks , G.X. Zhou , D.R. Lieberman , et al. , In situ moisture determination of a cytotoxic compound during process optimization , J. Pharm. Sci. , 92 ( 3 ), 495-501 ( 2003 ).
    • (2003) J. Pharm. Sci. , , vol.92 , Issue.3 , pp. 495-501
    • Hicks, M.B.1    Zhou, G.X.2    Lieberman, D.R.3
  • 40
    • 0037406496 scopus 로고    scopus 로고
    • Determination and differentiation of surface and bound water in drug substances by near infrared spectroscopy
    • G.X. Zhou , Z. Ge , J. Dorwart , B. Izzo , J. Kukura , G. Bicker and J. Wyvratt , Determination and differentiation of surface and bound water in drug substances by near infrared spectroscopy , J. Pharm. Sci. , 92 ( 5 ), 1058-1065 ( 2003 ).
    • (2003) J. Pharm. Sci. , , vol.92 , Issue.5 , pp. 1058-1065
    • Zhou, G.X.1    Ge, Z.2    Dorwart, J.3    Izzo, B.4    Kukura, J.5    Bicker, G.6    Wyvratt, J.7
  • 41
    • 0032071623 scopus 로고    scopus 로고
    • Dryer effl uent monitoring in a chemical pilot plant via fi ber-optic near-infrared spectroscopy
    • C. Coffey , A. Predoehl , D.S. Walker , Dryer effl uent monitoring in a chemical pilot plant via fi ber-optic near-infrared spectroscopy , Appl. Spectrosc. , 52 ( 5 ), 717-724 ( 1998 ).
    • (1998) Appl. Spectrosc. , , vol.52 , Issue.5 , pp. 717-724
    • Coffey, C.1    Predoehl, A.2    Walker, D.S.3
  • 42
    • 0033835301 scopus 로고    scopus 로고
    • Quantitative real-time monitoring of dryer effl uent using fi ber optic near-infrared spectroscopy
    • S.C. Harris and D.S. Walker , Quantitative real-time monitoring of dryer effl uent using fi ber optic near-infrared spectroscopy , J. Pharm. Sci. , 89 ( 9 ), 1180-1186 ( 2000 ).
    • (2000) J. Pharm. Sci. , , vol.89 , Issue.9 , pp. 1180-1186
    • Harris, S.C.1    Walker, D.S.2
  • 43
    • 5344234787 scopus 로고    scopus 로고
    • The role of solid nanoparticle technology in the parenteral delivery of poorly water-soluble drugs
    • J.E. Kipp , The role of solid nanoparticle technology in the parenteral delivery of poorly water-soluble drugs , Int. J. Pharm. , 284 , 109-122 ( 2004 ).
    • (2004) Int. J. Pharm. , vol.284 , pp. 109-122
    • Kipp, J.E.1
  • 44
    • 4243505839 scopus 로고    scopus 로고
    • Pharmaceutical nanosuspensions for medicament administration as systems with increased saturation solubility and rate of solution
    • US Patent 5858410
    • R.H. Muller , R. Becker , B. Kruss and K. Peters , Pharmaceutical nanosuspensions for medicament administration as systems with increased saturation solubility and rate of solution, US Patent 5858410 ( 1999 ).
    • (1999)
    • Muller, R.H.1    Becker, R.2    Kruss, B.3    Peters, K.4
  • 45
    • 0342897023 scopus 로고    scopus 로고
    • Nanosuspensions for the formulation of poorly soluble drugs I. Preparation by a size-reduction technique
    • R.H. Muller and K. Peters , Nanosuspensions for the formulation of poorly soluble drugs I. Preparation by a size-reduction technique , Int. J. Pharm. , 160 , 229-237 ( 1998 ).
    • (1998) Int. J. Pharm. , vol.160 , pp. 229-237
    • Muller, R.H.1    Peters, K.2
  • 46
    • 0037312695 scopus 로고    scopus 로고
    • Nanosizing: a formulation approach for poorly-water-soluble compounds
    • E. Merisko-Liversidge , G.G. Liversidge and E.R. Cooper , Nanosizing: a formulation approach for poorly-water-soluble compounds , Eur. J. Pharm. Sci. , 18 , 113-120 ( 2003 ).
    • (2003) Eur. J. Pharm. Sci. , vol.18 , pp. 113-120
    • Merisko-Liversidge, E.1    Liversidge, G.G.2    Cooper, E.R.3
  • 47
    • 1842559836 scopus 로고    scopus 로고
    • Nanoparticle engineering processes for enhancing the dissolution rates of poorly water soluble drugs
    • J. Hu , K.P. Johnston and R.O. Williams III , Nanoparticle engineering processes for enhancing the dissolution rates of poorly water soluble drugs , Drug Dev. Ind. Pharm. , 30 ( 3 ), 233-245 ( 2004 ).
    • (2004) Drug Dev. Ind. Pharm. , , vol.30 , Issue.3 , pp. 233-245
    • Hu, J.1    Johnston, K.P.2    Williams, R.O.3
  • 48
    • 0001944534 scopus 로고
    • Determination of particle size of pharmaceutical raw materials using near infrared refl ectance spectroscopy
    • E.W. Ciurczak , R.P. Tourlini and M.P. Demkowicz , Determination of particle size of pharmaceutical raw materials using near infrared refl ectance spectroscopy , Spectroscopy , 1 , 36-39 ( 1986 ).
    • (1986) Spectroscopy , vol.1 , pp. 36-39
    • Ciurczak, E.W.1    Tourlini, R.P.2    Demkowicz, M.P.3
  • 49
    • 0024053523 scopus 로고
    • Determination of particle size in powders by scatter correction in diffuse near infrared refl ectance
    • J.L. Ilari , H. Martens and T. Isaksson , Determination of particle size in powders by scatter correction in diffuse near infrared refl ectance , Appl. Spectrosc. , 42 , 722-728 ( 1988 ).
    • (1988) Appl. Spectrosc. , vol.42 , pp. 722-728
    • Ilari, J.L.1    Martens, H.2    Isaksson, T.3
  • 50
    • 0031736188 scopus 로고    scopus 로고
    • The application of multiple linear regression to the measurement of the median particle size of drugs and pharmaceutical excipients by near-infrared spectroscopy
    • A.J.O Neil , R. Jee and A.C. Moffat , The application of multiple linear regression to the measurement of the median particle size of drugs and pharmaceutical excipients by near-infrared spectroscopy , Analyst , 123 , 2297-2302 ( 1998 ).
    • (1998) Analyst , vol.123 , pp. 2297-2302
    • Neil, A.J.O.1    Jee, R.2    Moffat, A.C.3
  • 51
    • 0037446556 scopus 로고    scopus 로고
    • Spectroscopic approach for on-line monitoring of particle size during the processing of pharmaceutical nanoparticles
    • J.P. Higgins , S.M. Arrivo , G. Thurau , et al. , Spectroscopic approach for on-line monitoring of particle size during the processing of pharmaceutical nanoparticles , Anal. Chem. , 75 , 1777-1785 ( 2003 ).
    • (2003) Anal. Chem. , vol.75 , pp. 1777-1785
    • Higgins, J.P.1    Arrivo, S.M.2    Thurau, G.3
  • 53
  • 54
    • 0034767326 scopus 로고    scopus 로고
    • Process control and scale-up of pharmaceutical wet granulation processes: a review
    • A. Faure , P. York and R.C. Rowe , Process control and scale-up of pharmaceutical wet granulation processes: a review , Eur. J. Pharm. Biopharm. , 52 ( 3 ), 269-277 ( 2001 ).
    • (2001) Eur. J. Pharm. Biopharm. , , vol.52 , Issue.3 , pp. 269-277
    • Faure, A.1    York, P.2    Rowe, R.C.3
  • 55
    • 77951148598 scopus 로고    scopus 로고
    • Ensuring better control of granulation
    • available, accessed 27 November 2009
    • R.P. Patel and A.M. Suthar , Ensuring better control of granulation, available http://www.pharmamanufacturing. com/articles/2008/096.html?page=1 accessed 27 November 2009.
    • Patel, R.P.1    Suthar, A.M.2
  • 56
    • 0025736079 scopus 로고
    • Determination of end-point with a complex granulation applying infrared moisture sensor
    • S. Watano , K. Terashita and K. Miyanami , Determination of end-point with a complex granulation applying infrared moisture sensor , Chem. Pharm. Bull. , 39 ( 4 ), 1013-1017 ( 1991 ).
    • (1991) Chem. Pharm. Bull. , , vol.39 , Issue.4 , pp. 1013-1017
    • Watano, S.1    Terashita, K.2    Miyanami, K.3
  • 57
    • 0031009324 scopus 로고    scopus 로고
    • Process control and end-point determination of a fl uid bed granulation by application of near infra-red spectroscopy
    • P. Frake , D. Greenhalgh , S.M. Grierson , J.M. Hempenstall and D.R. Rudd , Process control and end-point determination of a fl uid bed granulation by application of near infra-red spectroscopy , Int. J. Pharm. , 151 , 75-80 ( 1997 ).
    • (1997) Int. J. Pharm. , vol.151 , pp. 75-80
    • Frake, P.1    Greenhalgh, D.2    Grierson, S.M.3    Hempenstall, J.M.4    Rudd, D.R.5
  • 58
    • 0032531185 scopus 로고    scopus 로고
    • On-line monitoring of moisture content in an instrumented fl uidized bed granulator with a multi-channel NIR moisture sensor
    • J. Rantanen , S. Lehtola , P. Ramet , J. Mannermaa , J. Yliruusi , On-line monitoring of moisture content in an instrumented fl uidized bed granulator with a multi-channel NIR moisture sensor , Powder Technol. , 99 ( 2 ), 163-170 ( 1998 ).
    • (1998) Powder Technol. , , vol.99 , Issue.2 , pp. 163-170
    • Rantanen, J.1    Lehtola, S.2    Ramet, P.3    Mannermaa, J.4    Yliruusi, J.5
  • 59
    • 0034665062 scopus 로고    scopus 로고
    • Application of acoustic emission to the monitoring and end point determination of a high shear granulation process
    • M. Whitaker , G.R. Baker , J. Westrup , P.A. Goulding , D.R. Rudd , R.M. Belchamber and M.P. Collins , Application of acoustic emission to the monitoring and end point determination of a high shear granulation process , Int. J. Pharm. , 205 , 79-91 ( 2000 ).
    • (2000) Int. J. Pharm. , vol.205 , pp. 79-91
    • Whitaker, M.1    Baker, G.R.2    Westrup, J.3    Goulding, P.A.4    Rudd, D.R.5    Belchamber, R.M.6    Collins, M.P.7
  • 60
    • 0035806248 scopus 로고    scopus 로고
    • Direct control of wet granulation processes by image processing system
    • S. Watano , Direct control of wet granulation processes by image processing system , Powder Technol. , 117 ( 1-2 ), 163-172 ( 2001 ).
    • (2001) Powder Technol. , , vol.117 , Issue.1-2 , pp. 163-172
    • Watano, S.1
  • 61
    • 12244273282 scopus 로고    scopus 로고
    • Use of in-line near-infrared spectroscopy in combination with chemometrics for improved understanding of pharmaceutical processes
    • J. Rantanen , H. Wikström , R. Turner , and L.S. Taylor , Use of in-line near-infrared spectroscopy in combination with chemometrics for improved understanding of pharmaceutical processes , Anal. Chem. , 77 ( 2 ), 556-563 ( 2005 ).
    • (2005) Anal. Chem. , , vol.77 , Issue.2 , pp. 556-563
    • Rantanen, J.1    Wikström, H.2    Turner, R.3    Taylor, L.S.4
  • 62
    • 39749101853 scopus 로고    scopus 로고
    • Real-time assessment of granule and tablet properties using in-line data from a high-shear granulation process
    • P. Luukkonen , M. Fransson , I.N. Björn , J. Hautala , B. Lagerholm and S. Folestad , Real-time assessment of granule and tablet properties using in-line data from a high-shear granulation process , J. Pharm. Sci. , 97 ( 2 ), 950-959 ( 2008 ).
    • (2008) J. Pharm. Sci. , , vol.97 , Issue.2 , pp. 950-959
    • Luukkonen, P.1    Fransson, M.2    Björn, I.N.3    Hautala, J.4    Lagerholm, B.5    Folestad, S.6
  • 63
    • 0035897679 scopus 로고    scopus 로고
    • Theoretical approaches to physical transformations of active pharmaceutical ingredients during manufacturing processes
    • K. Morris , U. Griesser , C. Eckhardt and J. Stowell , Theoretical approaches to physical transformations of active pharmaceutical ingredients during manufacturing processes , Adv. Drug Delivery Rev. , 48 ( 1 ), 91-114 ( 2001 ).
    • (2001) Adv. Drug Delivery Rev. , , vol.48 , Issue.1 , pp. 91-114
    • Morris, K.1    Griesser, U.2    Eckhardt, C.3    Stowell, J.4
  • 64
    • 12244274356 scopus 로고    scopus 로고
    • In-line monitoring of hydrate formation during wet granulation using Raman spectroscopy
    • H. Wikström , P.J. Marsac and L.S. Taylor , In-line monitoring of hydrate formation during wet granulation using Raman spectroscopy , J. Pharm. Sci. , 94 ( 1 ), 209-219 ( 2005 ).
    • (2005) J. Pharm. Sci. , , vol.94 , Issue.1 , pp. 209-219
    • Wikström, H.1    Marsac, P.J.2    Taylor, L.S.3
  • 65
    • 0028232120 scopus 로고
    • Online moisture detection for a microwave vacuum dryer
    • J.G. White , Online moisture detection for a microwave vacuum dryer , Pharm. Res. , 11 ( 5 ), 728-732 ( 1994 ).
    • (1994) Pharm. Res. , , vol.11 , Issue.5 , pp. 728-732
    • White, J.G.1
  • 66
    • 27544504382 scopus 로고    scopus 로고
    • In-line monitoring of moisture content in fl uid bed dryers using near-IR spectroscopy with consideration of sampling effects on method accuracy
    • R.L. Green , G. Thurau , N.C. Pixley , A. Mateos , R.A. Reed and J.P. Higgins , In-line monitoring of moisture content in fl uid bed dryers using near-IR spectroscopy with consideration of sampling effects on method accuracy , Anal. Chem. , 77 ( 40 ), 4515-4522 ( 2005 ).
    • (2005) Anal. Chem. , , vol.77 , Issue.40 , pp. 4515-4522
    • Green, R.L.1    Thurau, G.2    Pixley, N.C.3    Mateos, A.4    Reed, R.A.5    Higgins, J.P.6
  • 67
    • 33750971431 scopus 로고    scopus 로고
    • In-line monitoring of solid-state transitions during fl uidization
    • J. Aaltonen , K. Kogermann , C.J. Strachan and J. Rantanen , In-line monitoring of solid-state transitions during fl uidization , Chem. Eng. Sci. , 62 , 408-415 ( 2007 ).
    • (2007) Chem. Eng. Sci. , vol.62 , pp. 408-415
    • Aaltonen, J.1    Kogermann, K.2    Strachan, C.J.3    Rantanen, J.4
  • 68
    • 21844442597 scopus 로고    scopus 로고
    • Application of on-line Raman spectroscopy for characterizing relationships between drug hydration state and tablet physical stability
    • D.S. Hausman , R.T. Cambron and A. Sakr , Application of on-line Raman spectroscopy for characterizing relationships between drug hydration state and tablet physical stability , Int. J. Pharm. , 299 , 19-33 ( 2005 ).
    • (2005) Int. J. Pharm. , vol.299 , pp. 19-33
    • Hausman, D.S.1    Cambron, R.T.2    Sakr, A.3
  • 69
    • 41549091732 scopus 로고    scopus 로고
    • In-line monitoring of granule moisture in fl uidized-bed dryers using microwave resonance technology
    • C. Buschm ü ller , W. Wiedey , C. Döscher , J. Dressler and J. Breitkreutz , In-line monitoring of granule moisture in fl uidized-bed dryers using microwave resonance technology , Eur. J. Pharm. Biopharm. , 69 , 380-387 ( 2008 ).
    • (2008) Eur. J. Pharm. Biopharm. , vol.69 , pp. 380-387
    • Buschm ü ller, C.1    Wiedey, W.2    Döscher, C.3    Dressler, J.4    Breitkreutz, J.5
  • 70
    • 36549008702 scopus 로고    scopus 로고
    • Study growth kinetics in fl uidized bed granulation with at-line FBRM
    • X. Hu , J.C. Cunningham and D. Winstead , Study growth kinetics in fl uidized bed granulation with at-line FBRM , Int. J. Pharm. , 347 , 54-61 ( 2008 ).
    • (2008) Int. J. Pharm. , vol.347 , pp. 54-61
    • Hu, X.1    Cunningham, J.C.2    Winstead, D.3
  • 71
    • 84886146746 scopus 로고    scopus 로고
    • High Shear Wet Granulation
    • Mettler Toledo website, available, accessed 27 November 2009
    • High Shear Wet Granulation , Mettler Toledo website, available http://us.mt.com/mt/fi lters/applications_autochem-applications_formulation-autochem_formulation-granulation/High_Shear_Granulation_FilterHierarchy-Applicati onFamily_1198795528152.jsp accessed 27 November 2009.
  • 72
    • 84886141991 scopus 로고    scopus 로고
    • The Granulation Process 101: Basic Technologies for Tablet Making
    • available, accessed 27 November 2009
    • M.D. Tousey , The Granulation Process 101: Basic Technologies for Tablet Making, available http://pharmtech. fi ndpharma.com/pharmtech/data/articlestandard//pharmtech/432002/36208/article.pdf accessed 27 November 2009.
    • Tousey, M.D.1
  • 73
    • 1842482367 scopus 로고    scopus 로고
    • Nondestructive measurements of the compact strength and the particle-size distribution after milling of roller compacted powders by near-infrared spectroscopy
    • A. Gupta , G.E. Peck , R.W. Miller and K.R. Morris , Nondestructive measurements of the compact strength and the particle-size distribution after milling of roller compacted powders by near-infrared spectroscopy , J. Pharm. Sci. , 93 ( 4 ), 1047-1053 ( 2004 ).
    • (2004) J. Pharm. Sci. , , vol.93 , Issue.4 , pp. 1047-1053
    • Gupta, A.1    Peck, G.E.2    Miller, R.W.3    Morris, K.R.4
  • 74
    • 0033006842 scopus 로고    scopus 로고
    • Nondestructive tablet hardness testing by near-infrared spectroscopy: a new and robust spectral best-fi t algorithm
    • J.D. Kirsch and J.K. Drennen , Nondestructive tablet hardness testing by near-infrared spectroscopy: a new and robust spectral best-fi t algorithm , J. Pharm. Biomed. Anal. , 19 ( 3-4 ), 351-362 ( 1999 ).
    • (1999) J. Pharm. Biomed. Anal. , , vol.19 , Issue.3-4 , pp. 351-362
    • Kirsch, J.D.1    Drennen, J.K.2
  • 75
    • 23844524626 scopus 로고    scopus 로고
    • Infl uence of ambient moisture on the compaction behavior of microcrystalline cellulose powder undergoing uni-axial compression and roller compaction: a comparative study using near-infrared spectroscopy
    • A. Gupta , G.E. Peck , R.W. Miller and K.R. Morris , Infl uence of ambient moisture on the compaction behavior of microcrystalline cellulose powder undergoing uni-axial compression and roller compaction: a comparative study using near-infrared spectroscopy , J. Pharm. Sci. , 94 ( 10 ), 2301-2313 ( 2005 ).
    • (2005) J. Pharm. Sci. , , vol.94 , Issue.10 , pp. 2301-2313
    • Gupta, A.1    Peck, G.E.2    Miller, R.W.3    Morris, K.R.4
  • 78
    • 0034995187 scopus 로고    scopus 로고
    • The development of a blend-sampling technique to assess the uniformity of a powder mixture
    • T.P. Garcia , S.J. Wilkinson , and J.F. Scott , The development of a blend-sampling technique to assess the uniformity of a powder mixture , Drug Dev. Ind. Pharm. , 27 ( 4 ), 297-307 ( 2001 ).
    • (2001) Drug Dev. Ind. Pharm. , , vol.27 , Issue.4 , pp. 297-307
    • Garcia, T.P.1    Wilkinson, S.J.2    Scott, J.F.3
  • 79
    • 84886207928 scopus 로고    scopus 로고
    • USA vs. Barr Laboratories
    • 812 F. Supp., (D.N. J. 1993)
    • USA vs. Barr Laboratories, 812 F. Supp. 458, 485 (D.N. J. 1993).
    • , vol.458 , pp. 485
  • 80
    • 0029020143 scopus 로고
    • Blend uniformity and unit dose sampling
    • J. Berman and J.A. Planchard , Blend uniformity and unit dose sampling , Drug Dev. Ind. Pharm. , 21 ( 11 ), 1257-1283 ( 1995 ).
    • (1995) Drug Dev. Ind. Pharm. , , vol.21 , Issue.11 , pp. 1257-1283
    • Berman, J.1    Planchard, J.A.2
  • 81
  • 82
    • 0030217890 scopus 로고    scopus 로고
    • Near-infrared spectroscopic characterization of pharmaceutical powder blends
    • D.J. Wargo and J.K. Drennen , Near-infrared spectroscopic characterization of pharmaceutical powder blends , J. Pharm. Biomed. Anal. , 14 , 1415-1423 ( 1996 ).
    • (1996) J. Pharm. Biomed. Anal. , vol.14 , pp. 1415-1423
    • Wargo, D.J.1    Drennen, J.K.2
  • 83
    • 0000249159 scopus 로고    scopus 로고
    • On-line monitoring of powder blend homogeneity by near-infrared spectroscopy
    • S.S. Sekulic , H.W. Ward , II , D.R. Brannegan , et al. , On-line monitoring of powder blend homogeneity by near-infrared spectroscopy , Anal. Chem. , 68 , 509-513 ( 1996 ).
    • (1996) Anal. Chem. , vol.68 , pp. 509-513
    • Sekulic, S.S.1    Ward, H.W.2    Brannegan, D.R.3
  • 84
    • 0029894006 scopus 로고    scopus 로고
    • Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy Part I. System development and control
    • On-line PAT Applications of Spectroscopy in the Pharmaceutical Industry 459
    • P.A. Hailey , P. Doherty , P. Tapsell , T. Oliver and P.K. Aldridge , Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy Part I. System development and control , J. Pharm. Biomed. Anal. , 14 , 551-559 ( 1996 ). On-line PAT Applications of Spectroscopy in the Pharmaceutical Industry 459
    • (1996) J. Pharm. Biomed. Anal. , vol.14 , pp. 551-559
    • Hailey, P.A.1    Doherty, P.2    Tapsell, P.3    Oliver, T.4    Aldridge, P.K.5
  • 85
    • 0032582289 scopus 로고    scopus 로고
    • Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy Part II. Qualitative approaches to blend evaluation
    • S.S. Sekulic , J. Wakeman , P. Doherty and P.A. Hailey , Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy Part II. Qualitative approaches to blend evaluation , J. Pharm. Biomed. Anal. , 17 , 1285-1309 ( 1998 ).
    • (1998) J. Pharm. Biomed. Anal. , vol.17 , pp. 1285-1309
    • Sekulic, S.S.1    Wakeman, J.2    Doherty, P.3    Hailey, P.A.4
  • 86
    • 0030929920 scopus 로고    scopus 로고
    • Effective mass sampled by NIR fi ber-optic refl ectance probes in blending processes
    • J.H. Cho , P.J. Gemperline , P.K. Aldridge , S.S. Sekulic , Effective mass sampled by NIR fi ber-optic refl ectance probes in blending processes , Anal. Chim. Acta , 348 , 303-310 ( 1997 ).
    • (1997) Anal. Chim. Acta , vol.348 , pp. 303-310
    • Cho, J.H.1    Gemperline, P.J.2    Aldridge, P.K.3    Sekulic, S.S.4
  • 87
    • 0032565703 scopus 로고    scopus 로고
    • Estimation of effective sample size when analyzing powders with diffuse refl ectance near-infrared spectrometry
    • O. Berntsson , L-G. Danielsson and S. Folestad , Estimation of effective sample size when analyzing powders with diffuse refl ectance near-infrared spectrometry , Anal. Chim. Acta , 364 , 243-251 ( 1998 ).
    • (1998) Anal. Chim. Acta , vol.364 , pp. 243-251
    • Berntsson, O.1    Danielsson, L.-G.2    Folestad, S.3
  • 88
    • 0345863530 scopus 로고    scopus 로고
    • Application of a fl uorescence sensor for miniscale on-line monitoring of powder mixing kinetics
    • C-K. Lai and C.L. Cooney , Application of a fl uorescence sensor for miniscale on-line monitoring of powder mixing kinetics , J. Pharm. Sci. , 93 ( 1 ), 60-70 ( 2004 ).
    • (2004) J. Pharm. Sci. , , vol.93 , Issue.1 , pp. 60-70
    • Lai, C.-K.1    Cooney, C.L.2
  • 89
    • 0034825280 scopus 로고    scopus 로고
    • Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity
    • A.S. El-Hagrasy , H.R. Morris , F.D Amico , R.A. Lodder and J.K. Drennen III , Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity , J. Pharm. Sci. , 90 ( 9 ), 1298-1307 ( 2001 ).
    • (2001) J. Pharm. Sci. , , vol.90 , Issue.9 , pp. 1298-1307
    • El-Hagrasy, A.S.1    Morris, H.R.2    mico F.D3    Lodder, R.A.4    Drennen, J.K.5
  • 90
    • 32644440958 scopus 로고    scopus 로고
    • A process analytical technology approach to near-infrared process control of pharmaceutical powder blending. Part I: D-optimal design for characterization of powder mixing and preliminary spectral data evaluation
    • A.S. El-Hagrasy , F.D Amico and J.K. Drennen III , A process analytical technology approach to near-infrared process control of pharmaceutical powder blending. Part I: D-optimal design for characterization of powder mixing and preliminary spectral data evaluation , J. Pharm. Sci. , 95 ( 2 ), 392-406 ( 2006 ).
    • (2006) J. Pharm. Sci. , , vol.95 , Issue.2 , pp. 392-406
    • El-Hagrasy, A.S.1    mico F.D2    Drennen, J.K.3
  • 91
    • 32644437395 scopus 로고    scopus 로고
    • A process analytical technology approach to near-infrared process control of pharmaceutical powder blending. Part II: Qualitiative near-infrared models for prediction of blend homogeneity
    • A.S. El-Hagrasy , F.D Amico and J.K. Drennen III , A process analytical technology approach to near-infrared process control of pharmaceutical powder blending. Part II: Qualitiative near-infrared models for prediction of blend homogeneity , J. Pharm. Sci. , 95 ( 2 ), 407-421 ( 2006 ).
    • (2006) J. Pharm. Sci. , , vol.95 , Issue.2 , pp. 407-421
    • El-Hagrasy, A.S.1    mico F.D2    Drennen, J.K.3
  • 92
    • 32644436263 scopus 로고    scopus 로고
    • A process analytical technology approach to near-infrared process control of pharmaceutical powder blending. Part III: Quantitative near-infrared calibration for prediction of blend homogeneity and characterization of powder mixing kinetics
    • A.S. El-Hagrasy , F.D Amico and J.K. Drennen III , A process analytical technology approach to near-infrared process control of pharmaceutical powder blending. Part III: Quantitative near-infrared calibration for prediction of blend homogeneity and characterization of powder mixing kinetics , J. Pharm. Sci. , 95 ( 2 ), 422-434 ( 2006 ).
    • (2006) J. Pharm. Sci. , , vol.95 , Issue.2 , pp. 422-434
    • El-Hagrasy, A.S.1    mico F.D2    Drennen, J.K.3
  • 93
    • 52449121709 scopus 로고    scopus 로고
    • Characterization of pharmaceutical powder blends by NIR chemical imaging
    • H. Ma and C. Anderson , Characterization of pharmaceutical powder blends by NIR chemical imaging , J. Pharm. Sci. , 97 ( 8 ), 3305-3320 ( 2008 ).
    • (2008) J. Pharm. Sci. , , vol.97 , Issue.8 , pp. 3305-3320
    • Ma, H.1    Anderson, C.2
  • 95
    • 20444435015 scopus 로고    scopus 로고
    • Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity
    • D.S. Hausman , R.T. Cambron and A. Sakr , Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity , Int. J. Pharm. , 298 , 80-90 ( 2005 ).
    • (2005) Int. J. Pharm. , vol.298 , pp. 80-90
    • Hausman, D.S.1    Cambron, R.T.2    Sakr, A.3
  • 96
    • 0011657159 scopus 로고    scopus 로고
    • Real time and noninvasive monitoring of dry powder blend homogeneity
    • C-K. Lai , D. Holt , J.C. Leung and C.L. Cooney , Real time and noninvasive monitoring of dry powder blend homogeneity , AIChE J. , 47 ( 11 ), 2618-2622 ( 2001 ).
    • (2001) AIChE J. , , vol.47 , Issue.11 , pp. 2618-2622
    • Lai, C.-K.1    Holt, D.2    Leung, J.C.3    Cooney, C.L.4
  • 97
    • 0038155209 scopus 로고    scopus 로고
    • A homogeneity study using NIR spectroscopy: tracking magnesium stearate in Bohle Bin-Blender
    • N-H. Doung , P. Arratia , F. Muzzio , A. Lange , J. Timmermans and S. Reynolds , A homogeneity study using NIR spectroscopy: tracking magnesium stearate in Bohle Bin-Blender , Drug Dev. Ind. Pharm. , 29 ( 6 ), 679-687 ( 2003 ).
    • (2003) Drug Dev. Ind. Pharm. , , vol.29 , Issue.6 , pp. 679-687
    • Doung, N.-H.1    Arratia, P.2    Muzzio, F.3    Lange, A.4    Timmermans, J.5    Reynolds, S.6
  • 98
    • 33747106193 scopus 로고    scopus 로고
    • Evaluation of risk and benefi t in the implementation of near-infrared spectroscopy for monitoring of lubricant mixing
    • A.S. El-Hagrasy , S-Y. Chang and S. Kiang , Evaluation of risk and benefi t in the implementation of near-infrared spectroscopy for monitoring of lubricant mixing , Pharm. Dev. Technol. , 11 , 303-312 ( 2006 ).
    • (2006) Pharm. Dev. Technol. , vol.11 , pp. 303-312
    • El-Hagrasy, A.S.1    Chang, S.-Y.2    Kiang, S.3
  • 99
    • 34248667310 scopus 로고    scopus 로고
    • Near-infrared spectroscopic method for real-time monitoring of pharmaceutical powders during voiding
    • M.J. Barajas , A.R. Cassiana , W. Vargas , C. Conde , J. Ropero , J. Figueroa and R.J. Romanach , Near-infrared spectroscopic method for real-time monitoring of pharmaceutical powders during voiding , Appl. Spectrosc. , 61 ( 5 ), 490-496 ( 2007 ).
    • (2007) Appl. Spectrosc. , , vol.61 , Issue.5 , pp. 490-496
    • Barajas, M.J.1    Cassiana, A.R.2    Vargas, W.3    Conde, C.4    Ropero, J.5    Figueroa, J.6    Romanach, R.J.7
  • 101
    • 0000560917 scopus 로고
    • Near-infrared spectroscopy: applications in the analysis of tablets and solid pharmaceutical dosage forms
    • J.D. Kirsch and J.K. Drennen , Near-infrared spectroscopy: applications in the analysis of tablets and solid pharmaceutical dosage forms , Appl. Spectrosc. Rev. , 30 ( 3 ), 139-174 ( 1995 ).
    • (1995) Appl. Spectrosc. Rev. , vol.30 , Issue.3 , pp. 139-174
    • . Kirsch, J.1    Drennen, J.K.2
  • 102
    • 0028891911 scopus 로고
    • Determination of fi lm-coated tablet parameters by near-infrared spectroscopy
    • J.D. Kirsch and J.K. Drennen , Determination of fi lm-coated tablet parameters by near-infrared spectroscopy , J. Pharm. Biomed. Anal. , 13 1273-1281 ( 1995 ).
    • (1995) J. Pharm. Biomed. Anal. , vol.13 , pp. 1273-1281
    • Kirsch, J.D.1    Drennen, J.K.2
  • 103
    • 0031041793 scopus 로고    scopus 로고
    • Near-infrared spectroscopy as a nondestructive alternative to conventional tablet hardness testing
    • K.M. Morisseau and C.T. Rhodes , Near-infrared spectroscopy as a nondestructive alternative to conventional tablet hardness testing , Pharm. Res. , 14 ( 1 ), 108-111 ( 1997 ).
    • (1997) Pharm. Res. , , vol.14 , Issue.1 , pp. 108-111
    • Morisseau, K.M.1    Rhodes, C.T.2
  • 104
    • 0036605679 scopus 로고    scopus 로고
    • Rapid at-line analysis of coating thickness and uniformity on tablets using laser induced breakdown spectroscopy
    • M.D. Mowery , R. Sing , J. Kirsch , A. Razaghi , S. Béchard and R.A. Reed , Rapid at-line analysis of coating thickness and uniformity on tablets using laser induced breakdown spectroscopy , J. Pharm. Biomed. Anal. , 28 , 935-943 ( 2002 ).
    • (2002) J. Pharm. Biomed. Anal. , vol.28 , pp. 935-943
    • Mowery, M.D.1    Sing, R.2    Kirsch, J.3    Razaghi, A.4    Béchard, S.5    Reed, R.A.6
  • 105
    • 39749133046 scopus 로고    scopus 로고
    • Process analytical technology (PAT): quantifi cation approaches in terahertz spectroscopy for pharmaceutical application
    • H. Wu , E.J. Heilweil , A.S. Hussain and M.A. Khan , Process analytical technology (PAT): quantifi cation approaches in terahertz spectroscopy for pharmaceutical application , J. Pharm. Sci. , 97 , 970-984 ( 2008 ).
    • (2008) J. Pharm. Sci. , vol.97 , pp. 970-984
    • Wu, H.1    Heilweil, E.J.2    . Hussain, A.3    Khan, M.A.4
  • 106
    • 33750026177 scopus 로고    scopus 로고
    • A process analytical technology approach based on near infrared spectroscopy: tablet hardness, content uniformity, and dissolution test measurements of intact tablets
    • M. Blanco , M. Alcal á , J.M. Gonzá lez and E. Torras , A process analytical technology approach based on near infrared spectroscopy: tablet hardness, content uniformity, and dissolution test measurements of intact tablets , J. Pharm. Sci. , 95 , 2137-2144 ( 2006 ).
    • (2006) J. Pharm. Sci. , vol.95 , pp. 2137-2144
    • Blanco, M.1    Alcalá, M.2    González, J.M.3    Torras, E.4
  • 107
    • 21244448416 scopus 로고    scopus 로고
    • Multivariate data analysis for Raman imaging of a model pharmaceutical tablet
    • L. Zhang , M. Henson and S. Sekulic , Multivariate data analysis for Raman imaging of a model pharmaceutical tablet , Anal. Chim. Acta , 545 ( 2 ), 262-278 ( 2005 ).
    • (2005) Anal. Chim. Acta , , vol.545 , Issue.2 , pp. 262-278
    • Zhang, L.1    Henson, M.2    Sekulic, S.3
  • 108
    • 0030904679 scopus 로고    scopus 로고
    • Determination of moisture in hard gelatin capsules using near-infrared spectroscopy: applications to at-line process control of pharmaceutics
    • O. Berntsson , G. Zackrisson and G.Östling , Determination of moisture in hard gelatin capsules using near-infrared spectroscopy: applications to at-line process control of pharmaceutics , J. Pharm. Biomed. Anal. , 15 , 895-900 ( 1997 ).
    • (1997) J. Pharm. Biomed. Anal. , vol.15 , pp. 895-900
    • Berntsson, O.1    Zackrisson, G.2    Ö stling, G.3
  • 109
    • 34248196448 scopus 로고    scopus 로고
    • Non-invasive probing of pharmaceutical capsules using transmission Raman spectroscopy
    • P. Matousek and A.W. Parker , Non-invasive probing of pharmaceutical capsules using transmission Raman spectroscopy , J. Raman Spectrosc. , 38 ( 5 ), 563-567 ( 2007 ).
    • (2007) J. Raman Spectrosc. , , vol.38 , Issue.5 , pp. 563-567
    • Matousek, P.1    Parker, A.W.2
  • 110
    • 42749094654 scopus 로고    scopus 로고
    • Non-invasive quantitative assessment of the content of pharmaceutical capsules using transmission Raman spectroscopy
    • C. Eliasson , N.A. Macleod , L.C. Jayes , F.C. Clarke , S.V. Hammond , M.R. Smith and P. Matousek , Non-invasive quantitative assessment of the content of pharmaceutical capsules using transmission Raman spectroscopy , J. Pharm. Biomed. Anal. , 47 , 221-229 ( 2008 ).
    • (2008) J. Pharm. Biomed. Anal. , vol.47 , pp. 221-229
    • Eliasson, C.1    Macleod, N.A.2    Jayes, L.C.3    Clarke, F.C.4    Hammond, S.V.5    Smith, M.R.6    Matousek, P.7
  • 111
    • 23144434580 scopus 로고    scopus 로고
    • Nondestructive and on-line monitoring of tablets using light-induced fl uorescence technology
    • Article 3
    • C.K. Lai , A. Zahari , B. Miller , W.E. Katstra , M.J. Cimna and C.L. Cooney , Nondestructive and on-line monitoring of tablets using light-induced fl uorescence technology , AAPS PharmSciTech , 5 ( 1 ), Article 3 ( http://www.aapspharmscitech. org/ ) ( 2004 ).
    • (2004) AAPS PharmSciTech , vol.5 , Issue.1
    • Lai, C.K.1    Zahari, A.2    Miller, B.3    Katstra, W.E.4    Cimna, M.J.5    Cooney, C.L.6
  • 112
    • 0028891911 scopus 로고
    • Determination of fi lm-coated tablet parameters by near-infrared spectroscopy
    • J.D. Kirsch and J.K. Drennen , Determination of fi lm-coated tablet parameters by near-infrared spectroscopy , J. Pharm. Biomed. Anal. , 13 , 1273-1281 ( 1995 ).
    • (1995) J. Pharm. Biomed. Anal. , vol.13 , pp. 1273-1281
    • Kirsch, J.D.1    Drennen, J.K.2
  • 113
    • 0036605679 scopus 로고    scopus 로고
    • Rapid at-line analysis of coating thickness and uniformity on tablets using laser induced breakdown spectroscopy
    • M.D. Mowery , R. Sing , J. Kirsch , A. Razaghi , S. Béchard and R.A. Reed , Rapid at-line analysis of coating thickness and uniformity on tablets using laser induced breakdown spectroscopy , J. Pharm. Biomed. Anal. , 28 , 935-943 ( 2002 ).
    • (2002) J. Pharm. Biomed. Anal. , vol.28 , pp. 935-943
    • Mowery, M.D.1    Sing, R.2    Kirsch, J.3    Razaghi, A.4    Béchard, S.5    Reed, R.A.6
  • 114
    • 43249090114 scopus 로고    scopus 로고
    • Delayed release tablet dissolution related to coating thickness by terahertz pulsed image mapping
    • J.A. Spencer , Z. Gao , T. Moore , et al. , Delayed release tablet dissolution related to coating thickness by terahertz pulsed image mapping , J. Pharm. Sci. , 97 ( 4 ), 1543-1550 ( 2008 ).
    • (2008) J. Pharm. Sci. , , vol.97 , Issue.4 , pp. 1543-1550
    • Spencer, J.A.1    Gao, Z.2    Moore, T.3
  • 115
    • 37349045962 scopus 로고    scopus 로고
    • Characterization of tablet fi lm coatings using a laser-induced breakdown spectroscopic technique
    • Article 103
    • M.C. Madamba , W.M. Mullett , S. Debnath and E. Kwong , Characterization of tablet fi lm coatings using a laser-induced breakdown spectroscopic technique , AAPS PharmSciTech , 8 ( 4 ) Article 103 ( http://www. aapspharmscitech.org/ ) ( 2007 ).
    • (2007) AAPS PharmSciTech , , vol.8 , Issue.4
    • Madamba, M.C.1    Mullett, W.M.2    Debnath, S.3    Kwong, E.4
  • 118
    • 0034192551 scopus 로고    scopus 로고
    • Quantitative analysis of fi lm coating in a fl uidized bed process by in-line NIR spectrometry and multivariate batch calibration
    • M. Andersson , S. Folestad , J. Gottfries , M.O. Johansson , M. Josefson and K-G Wahlund , Quantitative analysis of fi lm coating in a fl uidized bed process by in-line NIR spectrometry and multivariate batch calibration , Anal. Chem. , 72 , 2099-2108 ( 2000 ).
    • (2000) Anal. Chem. , vol.72 , pp. 2099-2108
    • Andersson, M.1    Folestad, S.2    Gottfries, J.3    Johansson, M.O.4    Josefson, M.5    ahlund, K.-G.6
  • 119
    • 27844500635 scopus 로고    scopus 로고
    • Quantitative analysis of fi lm coating in a pan coater based on in-line sensor measurements
    • Article 20
    • J.D. Pérez-Ramos , W.P. Findlay , G. Peck and K.R. Morris , Quantitative analysis of fi lm coating in a pan coater based on in-line sensor measurements , AAPS PharmSciTech , 6 ( 1 ) Article 20 ( http://www.aapspharmscitech.org ) ( 2005 ).
    • (2005) AAPS PharmSciTech , , vol.6 , Issue.1
    • Pérez-Ramos, J.D.1    Findlay, W.P.2    Peck, G.3    Morris, K.R.4
  • 120
    • 0022266606 scopus 로고
    • The development and application of biosensing devices for bioreactor monitoring and control
    • D.J. Clarke , M.R. Calder , R.J. Carr , B.C. Blake-Coleman , S.C. Moody and T.A. Collinge , The development and application of biosensing devices for bioreactor monitoring and control , Biosensors , 1 ( 3 ), 213-320 ( 1985 ).
    • (1985) Biosensors , , vol.1 , Issue.3 , pp. 213-320
    • Clarke, D.J.1    Calder, M.R.2    Carr, R.J.3    Blake-Coleman, B.C.4    Moody, S.C.5    Collinge, T.A.6
  • 121
    • 0025708350 scopus 로고
    • Noninvasive method for monitoring in fermentation processes using fi beroptic near-infrared spectroscopy
    • A.G. Cavinato , D.M. Mayes , Z.H. Ge and J.B. Callis , Noninvasive method for monitoring in fermentation processes using fi beroptic near-infrared spectroscopy , Anal. Chem. , 62 ( 18 ), 1977-1982 ( 1990 ).
    • (1990) Anal. Chem. , , vol.62 , Issue.18 , pp. 1977-1982
    • Cavinato, A.G.1    Mayes, D.M.2    Ge, Z.H.3    Callis, J.B.4
  • 122
    • 0028406535 scopus 로고
    • Noninvasive spectroscopy for monitoring cell-density in a fermentation process
    • Z.H. Ge , A.G. Cavinato and J.B. Callis , Noninvasive spectroscopy for monitoring cell-density in a fermentation process , Anal. Chem. , 66 ( 8 ), 1354-1362 ( 1994 ).
    • (1994) Anal. Chem. , , vol.66 , Issue.8 , pp. 1354-1362
    • Ge, Z.H.1    Cavinato, A.G.2    Callis, J.B.3
  • 123
    • 0037145636 scopus 로고    scopus 로고
    • Use of at-line and in-situ near-infrared spectroscopy to monitor biomass in an industrial fed-batch Escherichia coli process
    • S.A. Arnold , R. Gaensakoo , L.M. Harvey and B. McNeil , Use of at-line and in-situ near-infrared spectroscopy to monitor biomass in an industrial fed-batch Escherichia coli process , Biotechnol Bioeng , 80 , 405-413 ( 2002 ).
    • (2002) Biotechnol Bioeng , vol.80 , pp. 405-413
    • Arnold, S.A.1    Gaensakoo, R.2    Harvey, L.M.3    McNeil, B.4
  • 124
    • 0347413613 scopus 로고    scopus 로고
    • Assessment of in-line near-infrared spectroscopy for continuous monitoring of fermentation processes
    • S. Tosi , M. Rossi , E. Tamburini , G. Vaccari , A. Amaretti and D. Matteuzzi , Assessment of in-line near-infrared spectroscopy for continuous monitoring of fermentation processes , Biotechnol. Prog. , 19 , 1816-1821 ( 2003 ).
    • (2003) Biotechnol. Prog. , vol.19 , pp. 1816-1821
    • Tosi, S.1    Rossi, M.2    Tamburini, E.3    Vaccari, G.4    Amaretti, A.5    Matteuzzi, D.6
  • 125
    • 43049183595 scopus 로고    scopus 로고
    • The use of NIR as a multi-parametric in situ monitoring technique in fi lamentous fermentation systems
    • L.O. Rodrigues , L. Vieira , J.P. Cardoso and J.C. Menezes , The use of NIR as a multi-parametric in situ monitoring technique in fi lamentous fermentation systems , Talanta , 75 , 1356-1361 ( 2008 ).
    • (2008) Talanta , vol.75 , pp. 1356-1361
    • Rodrigues, L.O.1    Vieira, L.2    Cardoso, J.P.3    Menezes, J.C.4
  • 126
    • 0030257834 scopus 로고    scopus 로고
    • Determination of major compounds of alcoholic fermentation by middle-infrared spectroscopy: Study of temperature effects and calibration methods
    • P. Fayolle , D. Picque , B. Perret , E. Latrille , G. Corrieu , Determination of major compounds of alcoholic fermentation by middle-infrared spectroscopy: Study of temperature effects and calibration methods , Appl. Spectrosc. , 50 ( 10 ), 1325-1330 ( 1996 ).
    • (1996) Appl. Spectrosc. , , vol.50 , Issue.10 , pp. 1325-1330
    • Fayolle, P.1    Picque, D.2    Perret, B.3    Latrille, E.4    Corrieu, G.5
  • 128
    • 29944447138 scopus 로고    scopus 로고
    • Monitoring alcoholic fermentation by joint use of soft and hard modeling methods
    • M. Blanco , A.C. Peinado and J. Mas , Monitoring alcoholic fermentation by joint use of soft and hard modeling methods , Anal. Chim. Acta , 556 , 364-373 ( 2006 ).
    • (2006) Anal. Chim. Acta , vol.556 , pp. 364-373
    • Blanco, M.1    Peinado, A.C.2    Mas, J.3
  • 130
    • 0037335194 scopus 로고    scopus 로고
    • In-situ near-infrared spectroscopy monitoring of the lyophilization process
    • M. Br ü lls , S. Folestad , A. Sparén , and A. Rasmuson , In-situ near-infrared spectroscopy monitoring of the lyophilization process , Pharm. Res. , 20 ( 3 ), 494-499 ( 2003 ).
    • (2003) Pharm. Res. , , vol.20 , Issue.3 , pp. 494-499
    • Br ü lls, M.1    Folestad, S.2    Sparén, A.3    Rasmuson, A.4
  • 131
    • 35848946390 scopus 로고    scopus 로고
    • Implementation of a process analytical technology system in a freeze-drying process using Raman spectroscopy for in-line process monitoring
    • T.R.M. De Beer , M. Alles oslash; , F. Goethals , et al. , Implementation of a process analytical technology system in a freeze-drying process using Raman spectroscopy for in-line process monitoring , Anal. Chem. , 79 , 7992-8003 ( 2007 ).
    • (2007) Anal. Chem. , vol.79 , pp. 7992-8003
    • De Beer, T.R.M.1    Alles oslash2    , M.3    Goethals, F.4
  • 132
    • 34247523197 scopus 로고    scopus 로고
    • Monitoring of mannitol phase behavior during freeze-drying using non-invasive Raman spectroscopy
    • S. Romero-Torres , H. Wikstrom , E.R. Grant and L.S. Taylor , Monitoring of mannitol phase behavior during freeze-drying using non-invasive Raman spectroscopy , PDA J. Pharm. Sci. Technol. , 61 ( 2 ), 131-145 ( 2007 ).
    • (2007) PDA J. Pharm. Sci. Technol. , , vol.61 , Issue.2 , pp. 131-145
    • Romero-Torres, S.1    Wikstrom, H.2    Grant, E.R.3    Taylor, L.S.4
  • 133
    • 34547212342 scopus 로고    scopus 로고
    • Evaluation of tunable diode laser absorption spectroscopy for in-process water vapor mass fl ux measurements during freeze drying
    • H. Gieseler , W.J. Kessler , M. Finson , et al. , Evaluation of tunable diode laser absorption spectroscopy for in-process water vapor mass fl ux measurements during freeze drying , J. Pharm. Sci. , 96 ( 7 ), 1776-1793 ( 2007 ).
    • (2007) J. Pharm. Sci. , , vol.96 , Issue.7 , pp. 1776-1793
    • Gieseler, H.1    Kessler, W.J.2    Finson, M.3
  • 137
    • 33846997207 scopus 로고    scopus 로고
    • Grazing-angle fi ber-optic Fourier transform infrared refl ection-absorption spectroscopy for in situ detection and quantifi cation of two active pharmaceutical ingredients on glass
    • B.B. Perston , M.L. Hamilton , B.E. Williamson , P.W. Harland , M.A. Thomson and P.J. Melling , Grazing-angle fi ber-optic Fourier transform infrared refl ection-absorption spectroscopy for in situ detection and quantifi cation of two active pharmaceutical ingredients on glass , Anal. Chem. , 79 , 1231-1236 ( 2007 ).
    • (2007) Anal. Chem. , vol.79 , pp. 1231-1236
    • Perston, B.B.1    Hamilton, M.L.2    Williamson, B.E.3    Harland, P.W.4    Thomson, M.A.5    Melling, P.J.6
  • 138
    • 55849102100 scopus 로고    scopus 로고
    • The application of PAT for cleaning and cleaning validation
    • M. Hellings and H. Vanbaelen , The application of PAT for cleaning and cleaning validation , Am. Pharm. Rev. , 11 ( 5 ), 12-18 ( 2008 ).
    • (2008) Am. Pharm. Rev. , , vol.11 , Issue.5 , pp. 12-18
    • Hellings, M.1    Vanbaelen, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.