메뉴 건너뛰기




Volumn 298, Issue 1, 2005, Pages 80-90

Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity

Author keywords

Blend uniformity; Content uniformity; Low dose; On line spectroscopy; Raman

Indexed keywords

AZIMILIDE; CROSPOVIDONE; LACTOSE; MAGNESIUM STEARATE;

EID: 20444435015     PISSN: 03785173     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijpharm.2005.04.011     Document Type: Article
Times cited : (84)

References (22)
  • 1
    • 0028046205 scopus 로고
    • Control analysis of a pharmaceutical preparation by near-infrared reflectance spectroscopy. a comparative study of a spinning module and fibre optic probe
    • M. Blanco, J. Coello, H. Iturriaga, S. Maspoch, C. de la Pezuela, and E. Russo Control analysis of a pharmaceutical preparation by near-infrared reflectance spectroscopy. A comparative study of a spinning module and fibre optic probe Anal. Chim. Acta 298 1994 183 191
    • (1994) Anal. Chim. Acta , vol.298 , pp. 183-191
    • Blanco, M.1    Coello, J.2    Iturriaga, H.3    Maspoch, S.4    De La Pezuela, C.5    Russo, E.6
  • 2
    • 0032006346 scopus 로고    scopus 로고
    • Quantitative characterization of mixing of dry powders in V-blenders
    • D. Brone, A. Alexander, and F. Muzzio Quantitative characterization of mixing of dry powders in V-blenders AICHE J. 44 2 1998 271 278
    • (1998) AICHE J. , vol.44 , Issue.2 , pp. 271-278
    • Brone, D.1    Alexander, A.2    Muzzio, F.3
  • 3
    • 0034641116 scopus 로고    scopus 로고
    • Enhanced mixing in double-cone blenders
    • D. Brone, and F. Muzzio Enhanced mixing in double-cone blenders Powder Technol. 110 2000 179 189
    • (2000) Powder Technol. , vol.110 , pp. 179-189
    • Brone, D.1    Muzzio, F.2
  • 4
    • 0003984877 scopus 로고
    • Pharmaceutical principles of solid dosage forms
    • J. Carstensen Pharmaceutical principles of solid dosage forms Technomic, Lancaster 1993 15 30
    • (1993) Technomic, Lancaster , pp. 15-30
    • Carstensen, J.1
  • 5
    • 1542327720 scopus 로고    scopus 로고
    • The use of a rotary tablet press as a compacting spinning riffler for blending validation
    • R.-K. Chang, X. Guo, and J.-W. Lai The use of a rotary tablet press as a compacting spinning riffler for blending validation Pharm. Tech., March 2004 78 84
    • (2004) Pharm. Tech., March , pp. 78-84
    • Chang, R.-K.1    Guo, X.2    Lai, J.-W.3
  • 7
    • 0034825280 scopus 로고    scopus 로고
    • Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity
    • A.S. El-Hagrasy, H.R. Morris, F. D'Amico, R.A. Lodder, and J.K. Drennen Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity J. Pharm. Sci. 90 9 2001 1298 1307
    • (2001) J. Pharm. Sci. , vol.90 , Issue.9 , pp. 1298-1307
    • El-Hagrasy, A.S.1    Morris, H.R.2    D'Amico, F.3    Lodder, R.A.4    Drennen, J.K.5
  • 8
    • 20444492526 scopus 로고    scopus 로고
    • Guidance for Industry. Powder blends and finished dosage units stratified
    • Center for Drug Evaluation and Research, Rockville, MD.
    • FDA, 2003. Guidance for Industry. Powder blends and finished dosage units stratified. In: Process Dosage Unit Sampling and Assessment. Center for Drug Evaluation and Research, Rockville, MD.
    • (2003) Process Dosage Unit Sampling and Assessment
  • 9
    • 20444445246 scopus 로고    scopus 로고
    • PAT Subcommittee of the Advisory Committee for Pharmaceutical Science Meeting Presentation, February 25.
    • Hussain, A., 2002. The Subcommittee on PAT: Overview and Objectives. PAT Subcommittee of the Advisory Committee for Pharmaceutical Science Meeting Presentation, February 25. http://www.fda.gov/ohrms/dockets/ac/02/slides/ 3841s1_01_hussain/sld001.htm
    • (2002) The Subcommittee on PAT: Overview and Objectives
    • Hussain, A.1
  • 10
    • 1542515281 scopus 로고    scopus 로고
    • Challenges of blend uniformity testing for tablet formulation
    • R. Hwang, and S. Wu Challenges of blend uniformity testing for tablet formulation Am. Pharm. Rev. 7 1 2004 101 103
    • (2004) Am. Pharm. Rev. , vol.7 , Issue.1 , pp. 101-103
    • Hwang, R.1    Wu, S.2
  • 14
    • 0141764844 scopus 로고    scopus 로고
    • Evaluation of the Conformity Index and the Mahalanobis Distance as a tool for process analysis: A technical note
    • G.E. Ritchie, H. Mark, and E.W. Ciurczak Evaluation of the Conformity Index and the Mahalanobis Distance as a tool for process analysis: a technical note AAPS Pharm. Sci. Technol. 4 2003 Article 24
    • (2003) AAPS Pharm. Sci. Technol. , vol.4
    • Ritchie, G.E.1    Mark, H.2    Ciurczak, E.W.3
  • 15
    • 0348025526 scopus 로고    scopus 로고
    • 4th ed. Pharmaceutical Press and American Pharmaceutical Association London and Washington, DC
    • R. Rowe P. Sheskey P. Weller Handbook of Pharmaceutical Excipients 4th ed. 2003 Pharmaceutical Press and American Pharmaceutical Association London and Washington, DC
    • (2003) Handbook of Pharmaceutical Excipients
    • Rowe Sheskey, P.R.1    Weller, P.2
  • 16
    • 20444470852 scopus 로고
    • The mixing action of rotary tableting machines.
    • P.H. Stahl, and F. Langenbucher The mixing action of rotary tableting machines. Pharm. Technol. 5 1981 51 59
    • (1981) Pharm. Technol. , vol.5 , pp. 51-59
    • Stahl, P.H.1    Langenbucher, F.2
  • 17
    • 20444438081 scopus 로고    scopus 로고
    • Uniformity of Dosage Units 〈905〉. United States Pharmacopeial Convention, Rockville, MD
    • US Pharmacopeia XXVII, 2004. Uniformity of Dosage Units 〈905〉. United States Pharmacopeial Convention, Rockville, MD, pp. 2396-2397.
    • (2004) Uniformity of Dosage Units 〈905〉 , pp. 2396-2397
  • 19
    • 0030217890 scopus 로고    scopus 로고
    • Near-infrared spectroscopic characterization of pharmaceutical powder blends
    • D. Wargo, and J. Drennen Near-infrared spectroscopic characterization of pharmaceutical powder blends J. Pharm. Biomed. Anal. 14 11 1996 1414 1423
    • (1996) J. Pharm. Biomed. Anal. , vol.14 , Issue.11 , pp. 1414-1423
    • Wargo, D.1    Drennen, J.2
  • 20
    • 0023406601 scopus 로고
    • Near-infrared spectrum qualification via Mahalanobis Distance determination
    • R. Whitfield, M. Gerger, and R. Sharp Near-infrared spectrum qualification via Mahalanobis Distance determination Appl. Spectrosc. 41 7 1987 1204 1213
    • (1987) Appl. Spectrosc. , vol.41 , Issue.7 , pp. 1204-1213
    • Whitfield, R.1    Gerger, M.2    Sharp, R.3
  • 21
    • 0030595050 scopus 로고    scopus 로고
    • Comparison of regularized discriminant analysis, linear discriminant analysis and quadratic discriminant analysis, applied to NIR data
    • W. Wu, Y. Mallet, B. Walczak, W. Penninckx, D.L. Massart, S. Heuerding, and F. Erni Comparison of regularized discriminant analysis, linear discriminant analysis and quadratic discriminant analysis, applied to NIR data Anal. Chim. Acta 329 1996 257 265
    • (1996) Anal. Chim. Acta , vol.329 , pp. 257-265
    • Wu, W.1    Mallet, Y.2    Walczak, B.3    Penninckx, W.4    Massart, D.L.5    Heuerding, S.6    Erni, F.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.