-
1
-
-
0001870188
-
Microstructures and microsystems in instrumental analysis
-
Cammann K, Hinkers H, Knoll M (1994) Microstructures and microsystems in instrumental analysis. Analusis 22:M19-M21.
-
(1994)
Analusis
, vol.22
-
-
Cammann, K.1
Hinkers, H.2
Knoll, M.3
-
2
-
-
0028513995
-
Miniaturizing a whole analytical laboratory down to chip size
-
Effenhauser CS, Manz A (1994) Miniaturizing a whole analytical laboratory down to chip size. Am Lab 26:15.
-
(1994)
Am Lab
, vol.26
, pp. 15
-
-
Effenhauser, C.S.1
Manz, A.2
-
3
-
-
84974993929
-
Technologies for sustained development - A new task for big science
-
Popp M, Hoffmann J (1993) Technologies for sustained development--a new task for big science. 18:180-184.
-
(1993)
, vol.18
, pp. 180-184
-
-
Popp, M.1
Hoffmann, J.2
-
4
-
-
0025207507
-
Miniaturized total chemical-analysis systems - A novel concept for chemical sensing
-
Manz A, Graber N, Widmer HM (1990) Miniaturized total chemical-analysis systems--a novel concept for chemical sensing. 1:244-248.
-
(1990)
, vol.1
, pp. 244-248
-
-
Manz, A.1
Graber, N.2
Widmer, H.M.3
-
5
-
-
0033784860
-
Microsystems technology for remote monitoring and control in sustainable agricultural practices
-
Roblin P, Barrow DA (2000) Microsystems technology for remote monitoring and control in sustainable agricultural practices. J Environ Monit 2:385-392.
-
(2000)
J Environ Monit
, vol.2
, pp. 385-392
-
-
Roblin, P.1
Barrow, D.A.2
-
7
-
-
0026976496
-
Determination of young moduli of micromechanical thin-films using the resonance method
-
Kiesewetter L, Zhang JM, Houdeau D, Steckenborn A (1992) Determination of young moduli of micromechanical thin-films using the resonance method. Sens Actuators, A, Phys 35:153-159.
-
(1992)
Sens Actuators, A, Phys
, vol.35
, pp. 153-159
-
-
Kiesewetter, L.1
Zhang, J.M.2
Houdeau, D.3
Steckenborn, A.4
-
8
-
-
0025698086
-
Resonating microbridge mass-flow sensor
-
Bouwstra S, Legtenberg R, Tilmans HAC, Elwenspoek M (1990) Resonating microbridge mass-flow sensor. Sens Actuators, A, Phys 21:332-335.
-
(1990)
Sens Actuators, A, Phys
, vol.21
, pp. 332-335
-
-
Bouwstra, S.1
Legtenberg, R.2
Tilmans, H.A.C.3
Elwenspoek, M.4
-
9
-
-
34547239174
-
Thermal and ambient-induced deflections of scanning force microscope cantilevers
-
Thundat T, Warmack RJ, Chen GY, Allison DP (1994) Thermal and ambient-induced deflections of scanning force microscope cantilevers. Appl Phys Lett 64:2894-2896.
-
(1994)
Appl Phys Lett
, vol.64
, pp. 2894-2896
-
-
Thundat, T.1
Warmack, R.J.2
Chen, G.Y.3
Allison, D.P.4
-
10
-
-
21544478947
-
Resonance response of scanning force microscopy cantilevers
-
Chen GY, Warmack RJ, Thundat T, Allison DP, Huang A (1994) Resonance response of scanning force microscopy cantilevers. Rev Sci Instrum 65:2532-2537.
-
(1994)
Rev Sci Instrum
, vol.65
, pp. 2532-2537
-
-
Chen, G.Y.1
Warmack, R.J.2
Thundat, T.3
Allison, D.P.4
Huang, A.5
-
11
-
-
21144470578
-
Imaging entire genetically functional DNA-molecules with the scanning tunneling microscope
-
Allison DP, Thundat T, Jacobson KB, Bottomley LA, Warmack RJ (1993) Imaging entire genetically functional DNA-molecules with the scanning tunneling microscope. J Vac Sci Technol, A, Vac Surf Films 11:816-819.
-
(1993)
J Vac Sci Technol, A, Vac Surf Films
, vol.11
, pp. 816-819
-
-
Allison, D.P.1
Thundat, T.2
Jacobson, K.B.3
Bottomley, L.A.4
Warmack, R.J.5
-
12
-
-
0033554758
-
Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers
-
Datskos PG, Sauers I (1999) Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers. Sens Actuators, B, Chem 61:75-82.
-
(1999)
Sens Actuators, B, Chem
, vol.61
, pp. 75-82
-
-
Datskos, P.G.1
Sauers, I.2
-
14
-
-
0030092040
-
Micromachined silicon cantilever paddles with piezoresistive readout for flow sensing
-
Su Y, Evans AGR, Brunnschweiler A (1996) Micromachined silicon cantilever paddles with piezoresistive readout for flow sensing. J Micromechanics Microengineering 6:69-72.
-
(1996)
J Micromechanics Microengineering
, vol.6
, pp. 69-72
-
-
Su, Y.1
Evans, A.G.R.2
Brunnschweiler, A.3
-
15
-
-
0032769127
-
An artificial nose based on a micromechanical cantilever array
-
Lang HP, Baller MK, Berger R, Gerber C, Gimzewski JK, Battiston FM, Fornaro P, Ramseyer JP, Meyer E, Guntherodt HJ (1999) An artificial nose based on a micromechanical cantilever array. Anal Chim Acta 393:59-65.
-
(1999)
Anal Chim Acta
, vol.393
, pp. 59-65
-
-
Lang, H.P.1
Baller, M.K.2
Berger, R.3
Gerber, C.4
Gimzewski, J.K.5
Battiston, F.M.6
Fornaro, P.7
Ramseyer, J.P.8
Meyer, E.9
Guntherodt, H.J.10
-
16
-
-
0037403562
-
Development of nanomechanical biosensors for detection of the pesticide DDT
-
Alvarez M, Calle A, Tamayo J, Lechuga LM, Abad A, Montoya A (2003) Development of nanomechanical biosensors for detection of the pesticide DDT. Biosens Bioelectron 18:649-653.
-
(2003)
Biosens Bioelectron
, vol.18
, pp. 649-653
-
-
Alvarez, M.1
Calle, A.2
Tamayo, J.3
Lechuga, L.M.4
Abad, A.5
Montoya, A.6
-
17
-
-
0037437327
-
Design and performance of a microcantilever-based hydrogen sensor
-
Baselt DR, Fruhberger B, Klaassen E, Cemalovic S, Britton CL Jr, Patel SV, Mlsna TE, McCorkle D, Warmack B (2003) Design and performance of a microcantilever-based hydrogen sensor. Sens Actuators, B 88:120-131.
-
(2003)
Sens Actuators B
, vol.88
, pp. 120-131
-
-
Baselt, D.R.1
Fruhberger, B.2
Klaassen, E.3
Cemalovic, S.4
Britton Jr., C.L.5
Patel, S.V.6
Mlsna, T.E.7
McCorkle, D.8
Warmack, B.9
-
18
-
-
13444253903
-
Hydration level monitoring using embedded piezoresistive microcantilever sensors
-
Gunter RL, Delinger WD, Porter TL, Stewart R, Reed J (2005). Hydration level monitoring using embedded piezoresistive microcantilever sensors. Med Eng Phys 27:215-220.
-
(2005)
Med Eng Phys
, vol.27
, pp. 215-220
-
-
Gunter, R.L.1
Delinger, W.D.2
Porter, T.L.3
Stewart, R.4
Reed, J.5
-
19
-
-
0036178311
-
In situ detection of calcium ions with chemically modified microcantilevers
-
Ji H-F, Thundat T (2002) In situ detection of calcium ions with chemically modified microcantilevers. Biosens Bioelectron 17:337-343.
-
(2002)
Biosens Bioelectron
, vol.17
, pp. 337-343
-
-
Ji, H.-F.1
Thundat, T.2
-
20
-
-
2342466041
-
Detection of 2,4-dinitrotoluene using microcantilever sensors
-
Pinnaduwage LA, Thundat T, Hawk JE, Hedden DL, Britt PF, Houser EJ, Stepnowski S, McGill RA, Bubb D (2004) Detection of 2,4-dinitrotoluene using microcantilever sensors. Sens Actuators, B 99:223-229.
-
(2004)
Sens Actuators B
, vol.99
, pp. 223-229
-
-
Pinnaduwage, L.A.1
Thundat, T.2
Hawk, J.E.3
Hedden, D.L.4
Britt, P.F.5
Houser, E.J.6
Stepnowski, S.7
McGill, R.A.8
Bubb, D.9
-
21
-
-
0038541966
-
An embedded polymer piezoresistive microcantilever sensor
-
Porter TL, Eastman MP, Macomber C, Delinger WG, Zhine R (2003) An embedded polymer piezoresistive microcantilever sensor. Ultramicroscopy 97:365-369.
-
(2003)
Ultramicroscopy
, vol.97
, pp. 365-369
-
-
Porter, T.L.1
Eastman, M.P.2
Macomber, C.3
Delinger, W.G.4
Zhine, R.5
-
22
-
-
0035133605
-
Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor
-
Tamayo J, Humphris ADL, Malloy AM, Miles MJ (2001) Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor. Ultramicroscopy 86:167-173.
-
(2001)
Ultramicroscopy
, vol.86
, pp. 167-173
-
-
Tamayo, J.1
Humphris, A.D.L.2
Malloy, A.M.3
Miles, M.J.4
-
23
-
-
0038035212
-
Self-excited piezoelectric microcantilever for gas detection
-
Zhou J, Li P, Zhang S, Huang Y, Yang P, Bao M, Ruan G (2003) Self-excited piezoelectric microcantilever for gas detection. Microelectron Eng 69:37-46.
-
(2003)
Microelectron Eng
, vol.69
, pp. 37-46
-
-
Zhou, J.1
Li, P.2
Zhang, S.3
Huang, Y.4
Yang, P.5
Bao, M.6
Ruan, G.7
-
24
-
-
1942542409
-
Attogram detection using nanoelectromechanical oscillators
-
Ilic B, Craighead HG, Krylov S, Senaratne W, Ober C, Neuzil P (2004) Attogram detection using nanoelectromechanical oscillators. J Appl Physi 75:3694-3703.
-
(2004)
J Appl Physi
, vol.75
, pp. 3694-3703
-
-
Ilic, B.1
Craighead, H.G.2
Krylov, S.3
Senaratne, W.4
Ober, C.5
Neuzil, P.6
-
25
-
-
0036326234
-
Adsorption kinetics and mechanical properties of thiol-modified DNA-oligos on gold investigated by microcantilever sensors
-
Rodolphe M, Jensenius H, Thaysen J, Christensen CB, Boisen A (2002) Adsorption kinetics and mechanical properties of thiol-modified DNA-oligos on gold investigated by microcantilever sensors. Ultramicroscopy 91:29-36.
-
(2002)
Ultramicroscopy
, vol.91
, pp. 29-36
-
-
Rodolphe, M.1
Jensenius, H.2
Thaysen, J.3
Christensen, C.B.4
Boisen, A.5
-
27
-
-
0035888391
-
Micromechanical cantilever-based biosensors
-
Raiteri R, Grattarola M, Butt H-J, Skladal P (2001) Micromechanical cantilever-based biosensors. Sens Actuators, B 79:115-126.
-
(2001)
Sens Actuators, B
, vol.79
, pp. 115-126
-
-
Raiteri, R.1
Grattarola, M.2
Butt, H.-J.3
Skladal, P.4
-
28
-
-
0035519437
-
Single cell detection with micromechanical oscillators
-
Ilic B, Czaplewski D, Zalalutdinov M, Craighead HG, Neuzil P, Campagnolo C, Batt C (2001) Single cell detection with micromechanical oscillators. J Vac Sci Technol, B 19:2825-2828.
-
(2001)
J Vac Sci Technol, B
, vol.19
, pp. 2825-2828
-
-
Ilic, B.1
Czaplewski, D.2
Zalalutdinov, M.3
Craighead, H.G.4
Neuzil, P.5
Campagnolo, C.6
Batt, C.7
-
29
-
-
0242270010
-
Viral detection using an embedded piezoresistive microcantilever sensor
-
Gunter RL, Delinger WG, Manygoats K, Kooser A, Porter TL (2003) Viral detection using an embedded piezoresistive microcantilever sensor. Sens Actuators, A 107:219-224.
-
(2003)
Sens Actuators, A
, vol.107
, pp. 219-224
-
-
Gunter, R.L.1
Delinger, W.G.2
Manygoats, K.3
Kooser, A.4
Porter, T.L.5
-
30
-
-
0242499140
-
Investigation of the antigen antibody reaction between anti-bovine serum albumin (a-BSA) and bovine serum albumin (BSA) using piezoresistive microcantilever based sensors
-
Kooser A, Manygoats K, Eastman MP, Porter TL (2003) Investigation of the antigen antibody reaction between anti-bovine serum albumin (a-BSA) and bovine serum albumin (BSA) using piezoresistive microcantilever based sensors. Biosens Bioelectron 19:503-508.
-
(2003)
Biosens Bioelectron
, vol.19
, pp. 503-508
-
-
Kooser, A.1
Manygoats, K.2
Eastman, M.P.3
Porter, T.L.4
-
31
-
-
7944230754
-
Modification of microcantilevers using layer-by-layer nanoassembly film for glucose measurement
-
Yan X, Ji H-F, Lvov Y (2004) Modification of microcantilevers using layer-by-layer nanoassembly film for glucose measurement. Chem Phys Lett 396:34-37.
-
(2004)
Chem Phys Lett
, vol.396
, pp. 34-37
-
-
Yan, X.1
Ji, H.-F.2
Lvov, Y.3
-
32
-
-
7544230375
-
Virus detection using nanoelectromechanical devices
-
Ilic B, Yang Y, Craighead HG (2004) Virus detection using nanoelectromechanical devices. Appl Phys Lett 85:2604-2606.
-
(2004)
Appl Phys Lett
, vol.85
, pp. 2604-2606
-
-
Ilic, B.1
Yang, Y.2
Craighead, H.G.3
-
33
-
-
17644415740
-
Optical sequential readout of microcantilever arrays for biological detection
-
Alvarez M, Tamayo J (2005) Optical sequential readout of microcantilever arrays for biological detection. Sens Actuators, B 106:687-690.
-
(2005)
Sens Actuators, B
, vol.106
, pp. 687-690
-
-
Alvarez, M.1
Tamayo, J.2
-
34
-
-
0344765512
-
Bioelectronic noses - A status report-part II
-
[Review]
-
Ziegler C, Gopel W, Hammerle H, Hatt H, Jung G, Laxhuber L, Schmidt HL, Schutz S, Vogtle F, Zell A (1998) Bioelectronic noses - a status report-part II [Review]. Biosens Bioelectron 13:539-571.
-
(1998)
Biosens Bioelectron
, vol.13
, pp. 539-571
-
-
Ziegler, C.1
Gopel, W.2
Hammerle, H.3
Hatt, H.4
Jung, G.5
Laxhuber, L.6
Schmidt, H.L.7
Schutz, S.8
Vogtle, F.9
Zell, A.10
-
35
-
-
0026470689
-
Biosensors: Recent trends
-
Vadgama P, Crump PW (1992) Biosensors: Recent trends. Analyst 117:1657-1670.
-
(1992)
Analyst
, vol.117
, pp. 1657-1670
-
-
Vadgama, P.1
Crump, P.W.2
-
36
-
-
0033829057
-
Phages from landscape libraries as substitute antibodies
-
Petrenko VA, Smith GP (2000) Phages from landscape libraries as substitute antibodies. Protein Eng 13:589-592.
-
(2000)
Protein Eng
, vol.13
, pp. 589-592
-
-
Petrenko, V.A.1
Smith, G.P.2
-
38
-
-
0037401049
-
Phage display for detection of biological threat agents
-
Petrenko VA, Vodyanoy VJ (2003) Phage display for detection of biological threat agents. J Microbiol Methods 53:253-262.
-
(2003)
J Microbiol Methods
, vol.53
, pp. 253-262
-
-
Petrenko, V.A.1
Vodyanoy, V.J.2
-
39
-
-
0001599569
-
Simultaneous liquid viscosity and density determination with piezoelectric unimorph cantilevers
-
Shih WY, Li XP, Gu HM, Shih WH, Aksay IA (2001) Simultaneous liquid viscosity and density determination with piezoelectric unimorph cantilevers. J Appl Physi 89:1497-1505.
-
(2001)
J Appl Physi
, vol.89
, pp. 1497-1505
-
-
Shih, W.Y.1
Li, X.P.2
Gu, H.M.3
Shih, W.H.4
Aksay, I.A.5
-
40
-
-
0003578102
-
Vibration: Fundamentals and practice
-
CRC, Boca Raton
-
De Silva CW (1999) Vibration: Fundamentals and practice. CRC, Boca Raton.
-
(1999)
-
-
De Silva, C.W.1
-
41
-
-
34248634103
-
-
Ansys ANSYS Release 8.0 Documentation
-
Ansys ANSYS Release 8.0 Documentation.
-
-
-
-
43
-
-
0003435501
-
Formulas for natural frequency and mode shape
-
Van Nostrand, New York
-
Blevins RD (1978) Formulas for natural frequency and mode shape. Van Nostrand, New York.
-
(1978)
-
-
Blevins, R.D.1
-
45
-
-
19744377305
-
An alternative solution to improve sensitivity of resonant microcantilever chemical sensors: Comparison between using high-order modes and reducing dimensions
-
Lochon F, Dufour I, Rebiere D (2005) An alternative solution to improve sensitivity of resonant microcantilever chemical sensors: Comparison between using high-order modes and reducing dimensions. Sens Actuators, B 108:979-985.
-
(2005)
Sens Actuators, B
, vol.108
, pp. 979-985
-
-
Lochon, F.1
Dufour, I.2
Rebiere, D.3
-
46
-
-
0242664700
-
Fracture strength of ultrananocrystalline diamond thin films - Identification of Weibull parameters
-
Espinosa HD, Peng B, Prorok BC, Moldovan N, Auciello O, Carlisle JA, Gruen DM, Mancini DC (2003) Fracture strength of ultrananocrystalline diamond thin films--identification of Weibull parameters. J Appl Physi 94:6076-6084.
-
(2003)
J Appl Physi
, vol.94
, pp. 6076-6084
-
-
Espinosa, H.D.1
Peng, B.2
Prorok, B.C.3
Moldovan, N.4
Auciello, O.5
Carlisle, J.A.6
Gruen, D.M.7
Mancini, D.C.8
-
47
-
-
0141959723
-
Mechanical properties of ultrananocrystalline diamond thin films relevant to MEMS/NEMS devices
-
Espinosa HD, Prorok BC, Peng B, Kim KH, Moldovan N, Auciello O, Carlisle JA, Gruen DM, Mancini DC (2003) Mechanical properties of ultrananocrystalline diamond thin films relevant to MEMS/NEMS devices. Exp Mech 43:256-268.
-
(2003)
Exp Mech
, vol.43
, pp. 256-268
-
-
Espinosa, H.D.1
Prorok, B.C.2
Peng, B.3
Kim, K.H.4
Moldovan, N.5
Auciello, O.6
Carlisle, J.A.7
Gruen, D.M.8
Mancini, D.C.9
-
48
-
-
26644435999
-
Microcantilever biosensors
-
Hansen KM, Thundat T (2005) Microcantilever biosensors. Methods 37:57-64.
-
(2005)
Methods
, vol.37
, pp. 57-64
-
-
Hansen, K.M.1
Thundat, T.2
-
49
-
-
23844467463
-
Moore's law in homeland defense: An integrated sensor platform based on silicon microcantilevers
-
Pinnaduwage LA, Ji HF, Thundat T (2005) Moore's law in homeland defense: An integrated sensor platform based on silicon microcantilevers. IEEE Sens J 5:774-785.
-
(2005)
IEEE Sens J
, vol.5
, pp. 774-785
-
-
Pinnaduwage, L.A.1
Ji, H.F.2
Thundat, T.3
-
50
-
-
33745625089
-
Effective mass and flow patterns of fluids surrounding microcantilevers
-
Dareing DW, Tian F, Thundat T (2006) Effective mass and flow patterns of fluids surrounding microcantilevers. Ultramicroscopy 106:789-794.
-
(2006)
Ultramicroscopy
, vol.106
, pp. 789-794
-
-
Dareing, D.W.1
Tian, F.2
Thundat, T.3
-
51
-
-
0028747824
-
Mechanical-properties of compositionally modulated Au-Ni Thin-Films - Nanoindentation and microcantilever deflection experiments
-
Baker SP, Nix WD (1994) Mechanical-properties of compositionally modulated Au-Ni Thin-Films--nanoindentation and microcantilever deflection experiments. J Mater Res 9:3131-3145.
-
(1994)
J Mater Res
, vol.9
, pp. 3131-3145
-
-
Baker, S.P.1
Nix, W.D.2
-
52
-
-
84972102741
-
Mechanical characterization of thin-films by micromechanical techniques
-
Schweitz JA (1992) Mechanical characterization of thin-films by micromechanical techniques. MRS Bull 17:34-45.
-
(1992)
MRS Bull
, vol.17
, pp. 34-45
-
-
Schweitz, J.A.1
-
53
-
-
0024069463
-
Mechanical deflection of cantilever microbeams - A new technique for testing the mechanical-properties of thin-films
-
Weihs TP, Hong S, Bravman JC, Nix WD (1988) Mechanical deflection of cantilever microbeams--a new technique for testing the mechanical-properties of thin-films. J Mater Res 3:931-942.
-
(1988)
J Mater Res
, vol.3
, pp. 931-942
-
-
Weihs, T.P.1
Hong, S.2
Bravman, J.C.3
Nix, W.D.4
-
54
-
-
0040055606
-
Measuring the strength and stiffness of thin film materials by mechanically deflecting cantilever microbeams
-
Weihs TP, Hong S, Bravman JC, Nix WD (1989) Measuring the strength and stiffness of thin film materials by mechanically deflecting cantilever microbeams. Mater Res Soc Symp Proc 402:87-92.
-
(1989)
Mater Res Soc Symp Proc
, vol.402
, pp. 87-92
-
-
Weihs, T.P.1
Hong, S.2
Bravman, J.C.3
Nix, W.D.4
-
55
-
-
0035530156
-
Mechanical testing of thin films and small structures
-
Kraft O, Volkert CA (2001) Mechanical testing of thin films and small structures. Adv Eng Mater 3:99-110.
-
(2001)
Adv Eng Mater
, vol.3
, pp. 99-110
-
-
Kraft, O.1
Volkert, C.A.2
-
56
-
-
12344282940
-
A microbeam bending method for studying stress-strain relations for metal thin films on silicon substrates
-
Florando JN, Nix WD (2005) A microbeam bending method for studying stress-strain relations for metal thin films on silicon substrates. J Mech Phys Solids 53:619-638.
-
(2005)
J Mech Phys Solids
, vol.53
, pp. 619-638
-
-
Florando, J.N.1
Nix, W.D.2
-
57
-
-
84874318324
-
Piezoresistive sensors
-
In: Gopel W, Hesse J, Zemel JN (eds) VHC Verlagsgesellschaft, Weinheim, Germany
-
Kloek B (2004) Piezoresistive sensors. In: Gopel W, Hesse J, Zemel JN (eds) Sensors. VHC Verlagsgesellschaft, Weinheim, Germany, pp 145-172.
-
(2004)
Sensors
, pp. 145-172
-
-
Kloek, B.1
-
58
-
-
0005029435
-
Advances in piezoresistive probes for atomic force microscopy
-
Stanford University
-
Harley JA (2002) Advances in piezoresistive probes for atomic force microscopy. Stanford University.
-
(2002)
-
-
Harley, J.A.1
-
59
-
-
21244442696
-
Development of a 3-DOF silicon piezoresistive micro accelerometer
-
Dao DV, Okada S, Dau VT, Toriyama T, Sugiyama S (2004) Development of a 3-DOF silicon piezoresistive micro accelerometer. IEEE, Proceedings of the 2004 International Symposium on Micro-Nanomechatronics and Human Science, pp 271-276.
-
(2004)
IEEE, Proceedings of the 2004 International Symposium on Micro-Nanomechatronics and Human Science
, pp. 271-276
-
-
Dao, D.V.1
Okada, S.2
Dau, V.T.3
Toriyama, T.4
Sugiyama, S.5
|