메뉴 건너뛰기




Volumn 18, Issue 5-6, 2003, Pages 649-653

Development of nanomechanical biosensors for detection of the pesticide DDT

Author keywords

Biosensors; DDT; Microcantilevers; Nanomechanics; Pesticide

Indexed keywords

ANTIBODIES; INSECTICIDES; MONOLAYERS; STRESSES;

EID: 0037403562     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(03)00035-6     Document Type: Conference Paper
Times cited : (167)

References (15)
  • 3
    • 0030014940 scopus 로고    scopus 로고
    • A sensitive method to measure change in the surface stress of solids
    • Butt H.J. A sensitive method to measure change in the surface stress of solids. J. Coll. Interf. Sci. 180:1996;251-260.
    • (1996) J. Coll. Interf. Sci. , vol.180 , pp. 251-260
    • Butt, H.J.1
  • 4
    • 0028309424 scopus 로고
    • Adhesion forces between individual ligand-receptor pairs
    • Florin E.L., Moy V.T., Gaub H.E. Adhesion forces between individual ligand-receptor pairs. Science. 264:1994;415-417.
    • (1994) Science , vol.264 , pp. 415-417
    • Florin, E.L.1    Moy, V.T.2    Gaub, H.E.3
  • 7
    • 0034953771 scopus 로고    scopus 로고
    • Gold nano-structures for transduction of biomolecular interactions into micrometer scale movements
    • Lavrik N.V., Tipple C.A., Sepaniak M.J., Datskos P.G. Gold nano-structures for transduction of biomolecular interactions into micrometer scale movements. Biomed. Microdevices. 3:2001;35-44.
    • (2001) Biomed. Microdevices , vol.3 , pp. 35-44
    • Lavrik, N.V.1    Tipple, C.A.2    Sepaniak, M.J.3    Datskos, P.G.4
  • 8
    • 0028007197 scopus 로고
    • Direct measurement of the forces between complementary strands of DNA
    • Lee G.U., Chrisey L.A., Colton R.J. Direct measurement of the forces between complementary strands of DNA. Science. 266:1994;771-773.
    • (1994) Science , vol.266 , pp. 771-773
    • Lee, G.U.1    Chrisey, L.A.2    Colton, R.J.3
  • 10
    • 0033554783 scopus 로고    scopus 로고
    • Sensing biological substances based on the bending of microfabricated cantilevers
    • Raiteri R., Nelles G., Butt H.J., Knoll K., Skladal P. Sensing biological substances based on the bending of microfabricated cantilevers. Sensors Actuators B. 61:1999;213-217.
    • (1999) Sensors Actuators B , vol.61 , pp. 213-217
    • Raiteri, R.1    Nelles, G.2    Butt, H.J.3    Knoll, K.4    Skladal, P.5
  • 12
    • 0035133605 scopus 로고    scopus 로고
    • Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor
    • Tamayo J., Humphris A.D., Malloy A.M., Miles M.J. Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor. Ultramicroscopy. 86:2001;167-173.
    • (2001) Ultramicroscopy , vol.86 , pp. 167-173
    • Tamayo, J.1    Humphris, A.D.2    Malloy, A.M.3    Miles, M.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.