메뉴 건너뛰기




Volumn , Issue , 2009, Pages 114-149

Hyphenated Techniques in Drug Discovery: Purity Assessment, Purification, Quantitative Analysis and Metabolite Identification

Author keywords

Challenges associated with sample analysis in support of early drug discovery; Column considerations; Evaporative light scattering detection (ELSD); Hyphenated techniques in drug discovery; Mass spectrometer robustness; Metabolite identification; Purification of reaction mixtures; Quantitative bioanalysis; Supercritical fluid chromatography (SFC) complementary separation technique

Indexed keywords

COLUMN CHROMATOGRAPHY; EFFLUENT TREATMENT; GAS CHROMATOGRAPHY; LIGHT SCATTERING; PURIFICATION; SUPERCRITICAL FLUIDS;

EID: 33846043762     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9781444305500.ch6     Document Type: Chapter
Times cited : (4)

References (92)
  • 2
    • 19944388647 scopus 로고    scopus 로고
    • A protocol for high-throughput drug mixture quantitation: fast LC-MS or flow injection analysis-MS?
    • Yu, K. & Balogh, M. (2001) A protocol for high-throughput drug mixture quantitation: fast LC-MS or flow injection analysis-MS? LC-GC, 19, 60-72.
    • (2001) LC-GC , vol.19 , pp. 60-72
    • Yu, K.1    Balogh, M.2
  • 3
    • 0031951186 scopus 로고    scopus 로고
    • Use of short columns and high flow rates for rapid gradient reversed-phase chromatography
    • Mutton, I.M. (1998) Use of short columns and high flow rates for rapid gradient reversed-phase chromatography. Chromatographia, 47, 291-298.
    • (1998) Chromatographia , vol.47 , pp. 291-298
    • Mutton, I.M.1
  • 4
    • 0035525677 scopus 로고    scopus 로고
    • Fast generic-gradient reverse-phase high-performance liquid chromatography using short-bore columns packed with small nonporous silica particles for the analysis of combinatorial libraries
    • Leroy, F., Presle, B., Verillon, F. & Verette, E. (2001) Fast generic-gradient reverse-phase high-performance liquid chromatography using short-bore columns packed with small nonporous silica particles for the analysis of combinatorial libraries. J. Chromatogr. Sci., 39, 487-490.
    • (2001) J. Chromatogr. Sci. , vol.39 , pp. 487-490
    • Leroy, F.1    Presle, B.2    Verillon, F.3    Verette, E.4
  • 5
    • 0035783184 scopus 로고    scopus 로고
    • New developments in the application of monolithic HPLC columns
    • Lubda, D., Cabrera, K., Kraas, W., Schaefer, C. & Cunningham, D. (2001) New developments in the application of monolithic HPLC columns. LC-GC, 19, 1186-1191.
    • (2001) LC-GC , vol.19 , pp. 1186-1191
    • Lubda, D.1    Cabrera, K.2    Kraas, W.3    Schaefer, C.4    Cunningham, D.5
  • 6
    • 0037096648 scopus 로고    scopus 로고
    • Current application of mass spectrometry to combinatorial chemistry
    • Cheng, X. & Hochlowski, J. (2002) Current application of mass spectrometry to combinatorial chemistry. Anal. Chem., 74, 2679-2690.
    • (2002) Anal. Chem. , vol.74 , pp. 2679-2690
    • Cheng, X.1    Hochlowski, J.2
  • 7
    • 0032126818 scopus 로고    scopus 로고
    • Comparison of LC detection methods in the investigation of non-UV detectable organic impurities in a drug substance
    • McCrossen, S.D., Bryant, D.K., Cook, B.R. & Richards, J.J. (1998) Comparison of LC detection methods in the investigation of non-UV detectable organic impurities in a drug substance. J. Pharm. Biomed. Anal., 17, 455-471.
    • (1998) J. Pharm. Biomed. Anal. , vol.17 , pp. 455-471
    • McCrossen, S.D.1    Bryant, D.K.2    Cook, B.R.3    Richards, J.J.4
  • 8
    • 0000595570 scopus 로고    scopus 로고
    • Simultaneous on-line characterization of small organic molecules derived from combinatorial libraries for identity, quantity and purity by reversed-phase HPLC with chemiluminescent nitrogen, UV and mass spectrometric detection
    • Taylor, E.W., Qian, M.G. & Dollinger, G.D. (1998) Simultaneous on-line characterization of small organic molecules derived from combinatorial libraries for identity, quantity and purity by reversed-phase HPLC with chemiluminescent nitrogen, UV and mass spectrometric detection. Anal. Chem., 70, 3339-3347.
    • (1998) Anal. Chem. , vol.70 , pp. 3339-3347
    • Taylor, E.W.1    Qian, M.G.2    Dollinger, G.D.3
  • 9
    • 0036498078 scopus 로고    scopus 로고
    • Determination of relative UV response factors for HPLC by use of chemiluminescent nitrogen-specific detector
    • Nussbaum, M.A., Baertschi, S.W. & Jansen, P.J. (2002) Determination of relative UV response factors for HPLC by use of chemiluminescent nitrogen-specific detector. J. Pharm. Biomed. Anal., 27, 983-993.
    • (2002) J. Pharm. Biomed. Anal. , vol.27 , pp. 983-993
    • Nussbaum, M.A.1    Baertschi, S.W.2    Jansen, P.J.3
  • 10
    • 0003048510 scopus 로고    scopus 로고
    • Automated high-throughput quantification of combinatorial arrays
    • Lewis, K., Phelps, D.&Sefler, A. (2000) Automated high-throughput quantification of combinatorial arrays. Am. Pharm. Rev., 3, 63-68.
    • (2000) Am. Pharm. Rev. , vol.3 , pp. 63-68
    • Lewis, K.1    Phelps, D.2    Sefler, A.3
  • 11
    • 84949917550 scopus 로고    scopus 로고
    • For example, see
    • For example, see www.chiral.fr.
  • 12
    • 0141675105 scopus 로고    scopus 로고
    • Studies of the relative stability of TFA adducts vs non-TFA analogues for combinatorial chemistry library members in DMSO in a repository compound collection
    • Hochlowski, J., Cheng, X., Sauer, D. & Djuric, S. (2003) Studies of the relative stability of TFA adducts vs non-TFA analogues for combinatorial chemistry library members in DMSO in a repository compound collection. J. Combinatorial Chem., 5, 345-349.
    • (2003) J. Combinatorial Chem. , vol.5 , pp. 345-349
    • Hochlowski, J.1    Cheng, X.2    Sauer, D.3    Djuric, S.4
  • 13
    • 0032559294 scopus 로고    scopus 로고
    • Automated analytical/preparative highperformance liquid chromatography-mass spectrometry system for the rapid characterisation and purification of compound libraries
    • Zeng, L., Burton, L., Yung, K., Shushan, B. & Kassel, D.B. (1998) Automated analytical/preparative highperformance liquid chromatography-mass spectrometry system for the rapid characterisation and purification of compound libraries. J Chromatogr. A, 794, 3-13.
    • (1998) J Chromatogr. A , vol.794 , pp. 3-13
    • Zeng, L.1    Burton, L.2    Yung, K.3    Shushan, B.4    Kassel, D.B.5
  • 14
    • 0001532712 scopus 로고    scopus 로고
    • Developments of a fully automated parallel HPLC/mass spectrometry system for the analytical characterization and preparative purification of combinatorial libraries
    • Zeng, L.&Kassel, D.B. (1998) Developments of a fully automated parallel HPLC/mass spectrometry system for the analytical characterization and preparative purification of combinatorial libraries. Anal. Chem., 70, 4380-4388.
    • (1998) Anal. Chem. , vol.70 , pp. 4380-4388
    • Zeng, L.1    Kassel, B.D.2
  • 15
    • 23044523783 scopus 로고    scopus 로고
    • Preparative LC/MS technology: a key component of the existing high speed synthesis platform at Syngenta
    • Diggelmann, M., Sporri, H. & Gassmann, E. (2001) Preparative LC/MS technology: a key component of the existing high speed synthesis platform at Syngenta. Chimia, 55, 23-25.
    • (2001) Chimia , vol.55 , pp. 23-25
    • Diggelmann, M.1    Sporri, H.2    Gassmann, E.3
  • 16
    • 0031372267 scopus 로고    scopus 로고
    • An automated system for the purification of combinatorial libraries by preparative LC/MS
    • Kibbey, C.E. (1997) An automated system for the purification of combinatorial libraries by preparative LC/MS. Lab. Robotics Automation, 9, 309-321.
    • (1997) Lab. Robotics Automation , vol.9 , pp. 309-321
    • Kibbey, C.E.1
  • 18
    • 0036646123 scopus 로고    scopus 로고
    • High-throughput massdirected parallel purification incorporating a multiplexed single quadrupole mass spectrometer
    • Xu, R., Wang, T., Isbell, J., Cai, Z., Sykes, C., Brailsford, A. & Kassel, D.B. (2002) High-throughput massdirected parallel purification incorporating a multiplexed single quadrupole mass spectrometer. Anal. Chem., 74, 3055-3062.
    • (2002) Anal. Chem. , vol.74 , pp. 3055-3062
    • Xu, R.1    Wang, T.2    Isbell, J.3    Cai, Z.4    Sykes, C.5    Brailsford, A.6    Kassel, D.B.7
  • 19
    • 84949917551 scopus 로고    scopus 로고
    • Purification and analysis of reaction arrays using a 4-channel prep-HPLC-MS system
    • 224 th ACS National Meeting, Boston, MA. August
    • Liu, J. (2002) Purification and analysis of reaction arrays using a 4-channel prep-HPLC-MS system, 224 th ACS National Meeting, Boston, MA. August 2002.
    • (2002)
    • Liu, J.1
  • 20
    • 0038297863 scopus 로고    scopus 로고
    • Two-pump at-column-dilution configuration for preparative liquid chromatography-mass spectrometry
    • Blom, K.F. (2002) Two-pump at-column-dilution configuration for preparative liquid chromatography-mass spectrometry. J. Combinatorial Chem., 4, 295-301.
    • (2002) J. Combinatorial Chem. , vol.4 , pp. 295-301
    • Blom, K.F.1
  • 22
    • 0141786953 scopus 로고    scopus 로고
    • Development of a custom highthroughput preparative liquid chromatography/mass spectrometer platform for the preparative purification and analytical analysis of compound libraries
    • Leister, W., Strauss, K., Wisnoski, D., Zhao, Z. & Lindsley, C. (2003) Development of a custom highthroughput preparative liquid chromatography/mass spectrometer platform for the preparative purification and analytical analysis of compound libraries. J. Combinatorial Chem., 5, 322-329.
    • (2003) J. Combinatorial Chem. , vol.5 , pp. 322-329
    • Leister, W.1    Strauss, K.2    Wisnoski, D.3    Zhao, Z.4    Lindsley, C.5
  • 23
    • 0037096179 scopus 로고    scopus 로고
    • Supercritical fluid and unified chromatography
    • For a review, see
    • For a review, see: Chester, T.L.&Pinkston, J.D. (2002) Supercritical fluid and unified chromatography. Anal. Chem., 74, 2801-2811.
    • (2002) Anal. Chem. , vol.74 , pp. 2801-2811
    • Chester, T.L.1    Pinkston, D.J.2
  • 24
  • 25
    • 0034609004 scopus 로고    scopus 로고
    • The development of a semi-preparatory scale supercritical fluid chromatograph for high-throughput purification of 'combi-chem' libraries
    • Berger, T.A., Fogleman, K., Staats, T., Bente, P., Crocket, I., Farrell, W. &. Osonubi, M., (2000) The development of a semi-preparatory scale supercritical fluid chromatograph for high-throughput purification of 'combi-chem' libraries. J. Biochem. Biophys. Methods., 43, 87-111.
    • (2000) J. Biochem. Biophys. Methods. , vol.43 , pp. 87-111
    • Berger, T.A.1    Fogleman, K.2    Staats, T.3    Bente, P.4    Crocket, I.5    Farrell, W.6    Osonubi, M.7
  • 26
    • 0035165720 scopus 로고    scopus 로고
    • Mass directed fractionation and isolation of pharmaceutical compounds by packed-column supercritical fluid chromatography/mass spectrometry
    • Wang, T., Barber, M., Hardt, I.&Kassel, D.B. (2001) Mass directed fractionation and isolation of pharmaceutical compounds by packed-column supercritical fluid chromatography/mass spectrometry. Rapid Commun. Mass Spectrom., 15, 2067-2075.
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 2067-2075
    • Wang, T.1    Barber, M.2    Hardt, I.3    Kassel, B.D.4
  • 28
    • 0035339061 scopus 로고    scopus 로고
    • High-throughput purification of compound libraries
    • Ripka, W.C., Barker, G. & Krakover, J. (2001) High-throughput purification of compound libraries. Drug Discovery Today, 6, 471-477.
    • (2001) Drug Discovery Today , vol.6 , pp. 471-477
    • Ripka, W.C.1    Barker, G.2    Krakover, J.3
  • 29
    • 0028965743 scopus 로고
    • Enantiomeric separation by packed column chiral supercritical fluid chromatography
    • Whatley, J. (1995) Enantiomeric separation by packed column chiral supercritical fluid chromatography. J. Chromatogr. A, 697, 251-255.
    • (1995) J. Chromatogr. A , vol.697 , pp. 251-255
    • Whatley, J.1
  • 30
    • 0042697374 scopus 로고    scopus 로고
    • Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry
    • Hopfgartner,G.&Bourgogne, E. (2003) Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry. Mass Spectrom. Rev., 22, 195-214.
    • (2003) Mass Spectrom. Rev. , vol.22 , pp. 195-214
    • Hopfgartner, G.1    Bourgogne, E.2
  • 31
    • 1842833762 scopus 로고    scopus 로고
    • Recent advances in use of LC/MS/MS for quantitative high-throughput bioanalytical support of drug discovery
    • Ackermann, B.L., Berna, M.J.&Murphy, A.T. (2002) Recent advances in use of LC/MS/MS for quantitative high-throughput bioanalytical support of drug discovery. Curr. Topics Med. Chem., 2, 53-66.
    • (2002) Curr. Topics Med. Chem. , vol.2 , pp. 53-66
    • Ackermann, B.L.1    Berna, M.J.2    Murphy, T.A.3
  • 32
    • 0033939588 scopus 로고    scopus 로고
    • High-speed HPLC/MS/MS analysis of biological fluids:a practical review
    • Brockman, A.H., Hiller, D.L. & Cole, R.O. (2000) High-speed HPLC/MS/MS analysis of biological fluids:a practical review. Curr. Opin. Drug Discovery Devel., 3, 432-438.
    • (2000) Curr. Opin. Drug Discovery Devel. , vol.3 , pp. 432-438
    • Brockman, A.H.1    Hiller, D.L.2    Cole, R.O.3
  • 33
    • 0004191820 scopus 로고
    • 4th edn, Wm C. Brown, Dubuque, Iowa
    • Fox, S.I. (1993) Human Physiology, 4th edn., p. 332. Wm C. Brown, Dubuque, Iowa.
    • (1993) Human Physiology , pp. 332
    • Fox, S.I.1
  • 34
    • 0347457589 scopus 로고    scopus 로고
    • Mass analysers for LC-MS
    • Advanstar Communications, Chester
    • Lemière, F. (2001) Mass analysers for LC-MS. LC-GC Europe Guide to LC-MS, pp. 22-28. Advanstar Communications, Chester.
    • (2001) LC-GC Europe Guide to LC-MS , pp. 22-28
    • Lemière, F.1
  • 35
    • 20044385771 scopus 로고    scopus 로고
    • Interfaces for LC-MS
    • Advanstar Communications, Chester
    • Lemière, F. (2001) Interfaces for LC-MS. LC-GC Europe Guide to LC-MS, pp. 29-35. Advanstar Communications, Chester.
    • (2001) LC-GC Europe Guide to LC-MS , pp. 29-35
    • Lemière, F.1
  • 36
    • 0032986050 scopus 로고    scopus 로고
    • The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds
    • Bonfiglio, R., King, R.C., Olah, T.V. & Merkle, K. (1999) The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. Rapid Commun. Mass Spectrom., 13, 1175-1185.
    • (1999) Rapid Commun. Mass Spectrom. , vol.13 , pp. 1175-1185
    • Bonfiglio, R.1    King, R.C.2    Olah, T.V.3    Merkle, K.4
  • 37
    • 0036448941 scopus 로고    scopus 로고
    • Ion suppression in LC-MS-MS-a case study
    • Nelson, M.D. & Dolan, J.W. (2002) Ion suppression in LC-MS-MS-a case study. LC-GC, 20, 24-32.
    • (2002) LC-GC , vol.20 , pp. 24-32
    • Nelson, M.D.1    Dolan, J.W.2
  • 38
    • 0037234906 scopus 로고    scopus 로고
    • Post-column infusion study of the 'dosing vehicle effect' in liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samples
    • Shou, W.Z., & Naidong, W. (2003) Post-column infusion study of the 'dosing vehicle effect' in liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samples. Rapid Commun. Mass Spectrom., 17, 589-597.
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 589-597
    • Shou, W.Z.1    Naidong, W.2
  • 39
    • 0037214121 scopus 로고    scopus 로고
    • Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays:application to drug discovery
    • Mei, H., Hsieh, Y., Nardo, C., Xu, X., Wang, S., Ng, K. & Korfmacher, W.A. (2003) Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays:application to drug discovery. Rapid Commun. Mass Spectrom., 17, 97-103.
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 97-103
    • Mei, H.1    Hsieh, Y.2    Nardo, C.3    Xu, X.4    Wang, S.5    Ng, K.6    Korfmacher, W.A.7
  • 40
    • 0032011562 scopus 로고    scopus 로고
    • Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations
    • Matuszewski, B.K., Constanzer, M.L., & Chavez-Eng, C.M. (1998) Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations. Anal. Chem., 70, 882-889.
    • (1998) Anal. Chem. , vol.70 , pp. 882-889
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 41
    • 0033833016 scopus 로고    scopus 로고
    • Rapid bioanalytical determination of dextromethorphan in canine plasma by dilute-and-shoot preparation combined with one minute per sample LC-MS/MS analysis to optimize formulations for drug delivery
    • McCauley-Myers, D.L., Eichhold, T.H., Bailey, R.E., Dobrozsi, D.J., Best, K.J., Hayes, J.W., II & Hoke, S.H., II (2000) Rapid bioanalytical determination of dextromethorphan in canine plasma by dilute-and-shoot preparation combined with one minute per sample LC-MS/MS analysis to optimize formulations for drug delivery. J. Pharm. Biomed. Anal. 23, 825-835.
    • (2000) J. Pharm. Biomed. Anal , vol.23 , pp. 825-835
    • McCauley-Myers, D.L.1    Eichhold, T.H.2    Bailey, R.E.3    Dobrozsi, D.J.4    Best, K.J.5    Hayes, J.W.6    Hoke, S.H.7
  • 42
    • 0037420211 scopus 로고    scopus 로고
    • Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography-tandem mass spectrometry
    • Polson, C., Sarkar, P., Incledon, B., Raguvaran, V. & Grant, R. (2003) Optimization of protein precipitation based upon effectiveness of protein removal and ionization effect in liquid chromatography-tandem mass spectrometry. J. Chromatogr. B, 785, 263-275.
    • (2003) J. Chromatogr. B , vol.785 , pp. 263-275
    • Polson, C.1    Sarkar, P.2    Incledon, B.3    Raguvaran, V.4    Grant, R.5
  • 43
    • 0346789751 scopus 로고    scopus 로고
    • New designs and formats in solid-phase extraction sample preparation
    • Majors, R.E. (2001) New designs and formats in solid-phase extraction sample preparation. LC-GC Europe, 14, 746-751.
    • (2001) LC-GC Europe , vol.14 , pp. 746-751
    • Majors, R.E.1
  • 45
    • 0038409064 scopus 로고    scopus 로고
    • Investigation of EDTA anticoagulant in plasma to improve the throughput of liquid chromatography/tandem mass spectrometric assays
    • Sadagopan, N.P., Li,W., Cook, J.A., Galvan, B.,Weller, D. L., Fountain, S.T. & Cohen, L.H. (2003) Investigation of EDTA anticoagulant in plasma to improve the throughput of liquid chromatography/tandem mass spectrometric assays. Rapid Commun. Mass Spectrom., 17, 1065-1070.
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 1065-1070
    • Sadagopan, N.P.1    Li, W.2    Cook, J.A.3    Galvan, B.4    Weller, L.D.5    Fountain, S.T.6    Cohen, L.H.7
  • 46
    • 0027427861 scopus 로고
    • Characterization of factors affecting the stability of frozen heparinized plasma
    • Palmer, D.S., Rosborough, D., Perkins, H., Bolton, T., Rock, G. & Ganz, P.R. (1993) Characterization of factors affecting the stability of frozen heparinized plasma. Vox Sanguinis, 65, 258-270.
    • (1993) Vox Sanguinis , vol.65 , pp. 258-270
    • Palmer, D.S.1    Rosborough, D.2    Perkins, H.3    Bolton, T.4    Rock, G.5    Ganz, P.R.6
  • 47
    • 0036500607 scopus 로고    scopus 로고
    • Collection, storage and filtration of in vivo study samples using 96-well filter plates to facilitate automated sample preparation and LC/MS/MS analysis
    • Berna, M., Murphy, A.T., Wilken, B. & Ackermann, B. (2002) Collection, storage and filtration of in vivo study samples using 96-well filter plates to facilitate automated sample preparation and LC/MS/MS analysis. Anal. Chem., 74, 1197-1201.
    • (2002) Anal. Chem. , vol.74 , pp. 1197-1201
    • Berna, M.1    Murphy, A.T.2    Wilken, B.3    Ackermann, B.4
  • 48
    • 0037974571 scopus 로고    scopus 로고
    • Cytochrome P450 inhibition using recombinant proteins and mass spectrometry/multiple reaction monitoring technology in a cassette incubation
    • Weaver, R., Graham, K.S., Beattie, I.G. & Riley R.J. (2003) Cytochrome P450 inhibition using recombinant proteins and mass spectrometry/multiple reaction monitoring technology in a cassette incubation. Drug Metab. Disposition, 31, 955-966.
    • (2003) Drug Metab. Disposition , vol.31 , pp. 955-966
    • Weaver, R.1    Graham, K.S.2    Beattie, I.G.3    Riley, R.J.4
  • 49
    • 0034163513 scopus 로고    scopus 로고
    • Higher throughput bioanalysis by automation of a protein precipitation assay using a 96-well format with detection by LC-MS/MS
    • Watt, A.P., Morrison, D., Locker, K.L. & Evans, D.C. (2000) Higher throughput bioanalysis by automation of a protein precipitation assay using a 96-well format with detection by LC-MS/MS. Anal. Chem., 72, 979-984.
    • (2000) Anal. Chem. , vol.72 , pp. 979-984
    • Watt, A.P.1    Morrison, D.2    Locker, K.L.3    Evans, D.C.4
  • 50
    • 0036001218 scopus 로고    scopus 로고
    • Determination of drug concentrations in plasma by a highly automated, generic and flexible protein precipitation and liquid chromatography/tandem mass spectrometry method applicable to the drug discovery environment
    • O'Connor, D., Clarke, D.E., Morrison, D. & Watt, A.P. (2002) Determination of drug concentrations in plasma by a highly automated, generic and flexible protein precipitation and liquid chromatography/tandem mass spectrometry method applicable to the drug discovery environment. Rapid Commun. Mass Spectrom., 16, 1065-1071.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 1065-1071
    • O'Connor, D.1    Clarke, D.E.2    Morrison, D.3    Watt, A.P.4
  • 51
    • 0032745091 scopus 로고    scopus 로고
    • Automated protein precipitation by filtration in the 96-well format
    • Biddlecombe, R.A. & Pleasance, S. (1999) Automated protein precipitation by filtration in the 96-well format. J. Chromatogr., B, 734, 257-265.
    • (1999) J. Chromatogr., B , vol.734 , pp. 257-265
    • Biddlecombe, R.A.1    Pleasance, S.2
  • 52
    • 0034212552 scopus 로고    scopus 로고
    • Bioanalytical high-throughput selected reaction monitoring-LC/MS determination of selected estrogen receptor modulators in human plasma: 2000 samples/day
    • Zweigenbaum, J. & Henion, J. (2000) Bioanalytical high-throughput selected reaction monitoring-LC/MS determination of selected estrogen receptor modulators in human plasma: 2000 samples/day. Anal. Chem., 72, 2446-2454.
    • (2000) Anal. Chem. , vol.72 , pp. 2446-2454
    • Zweigenbaum, J.1    Henion, J.2
  • 53
    • 0037384549 scopus 로고    scopus 로고
    • Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma
    • Eerkes, A., Shou,W.Z.&Naidong,W. (2003) Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma. J. Pharm. Biomed. Anal., 31, 917-928.
    • (2003) J. Pharm. Biomed. Anal. , vol.31 , pp. 917-928
    • Eerkes, A.1    Shou, W.Z.2    Naidong, W.3
  • 54
    • 0035253684 scopus 로고    scopus 로고
    • Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry
    • Peng, S.X., Branch, T.M. & King, S.L. (2001) Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry. Anal. Chem., 73, 708-714.
    • (2001) Anal. Chem. , vol.73 , pp. 708-714
    • Peng, S.X.1    Branch, T.M.2    King, S.L.3
  • 55
    • 0036255168 scopus 로고    scopus 로고
    • A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using internal standard (IS) 96-well diatomaceous earth plates for solid-liquid extraction
    • Wang, A.Q., Zeng, W., Musson, D.G., Rogers, J.D. & Fisher, A.L. (2002) A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using internal standard (IS) 96-well diatomaceous earth plates for solid-liquid extraction. Rapid. Commun. Mass Spectrom., 16, 975-981.
    • (2002) Rapid. Commun. Mass Spectrom. , vol.16 , pp. 975-981
    • Wang, A.Q.1    Zeng, W.2    Musson, D.G.3    Rogers, J.D.4    Fisher, A.L.5
  • 56
    • 0034655370 scopus 로고    scopus 로고
    • Automated 96-well SPE and LC-MS-MS for determination of protease inhibitors in plasma and cartilage tissues
    • Peng, S.X., King, S.L., Bornes, D.M., Foltz, D.J., Baker, T.R. & Natchus, M.G. (2000) Automated 96-well SPE and LC-MS-MS for determination of protease inhibitors in plasma and cartilage tissues. Anal. Chem., 72, 1913-1917.
    • (2000) Anal. Chem. , vol.72 , pp. 1913-1917
    • Peng, S.X.1    King, S.L.2    Bornes, D.M.3    Foltz, D.J.4    Baker, T.R.5    Natchus, M.G.6
  • 57
    • 0035067378 scopus 로고    scopus 로고
    • A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma
    • Shou,W.Z., Jiang, X., Beato, B.D. & Naidong,W. (2001) A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma. Rapid Commun. Mass Spectrom., 15, 466-476.
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 466-476
    • Shou, W.Z.1    Jiang, X.2    Beato, B.D.3    Naidong, W.4
  • 58
    • 0037235982 scopus 로고    scopus 로고
    • Performance of an ultra-lowelution-volume 96-well plate: drug discovery and development applications
    • Mallet, C.R., Lu, Z., Fisk, R., Mazzeo., J.R.&Neue, U.D. (2003) Performance of an ultra-lowelution-volume 96-well plate: drug discovery and development applications. Rapid Commun. Mass Spectrom., 17, 163-170.
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 163-170
    • Mallet, C.R.1    Lu, Z.2    Fisk, R.3    Mazzeo, J.R.4    Neue, D.U.5
  • 59
    • 0036393151 scopus 로고    scopus 로고
    • Liquid chromatography/tandem mass spectrometric bioanalysis using normal-phase columns with aqueous/organic mobile phases-a novel approach of eliminating evaporation and reconstitution steps in 96-well SPE
    • Naidong, W., Shou, W.Z., Addison, T., Maleki, S. & Jiang, X. (2002) Liquid chromatography/tandem mass spectrometric bioanalysis using normal-phase columns with aqueous/organic mobile phases-a novel approach of eliminating evaporation and reconstitution steps in 96-well SPE. Rapid Commun. Mass Spectrom., 16, 1965-1975.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 1965-1975
    • Naidong, W.1    Shou, W.Z.2    Addison, T.3    Maleki, S.4    Jiang, X.5
  • 60
    • 0032767701 scopus 로고    scopus 로고
    • Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry
    • Zimmer, D., Pickard, V., Czembor, W. & Müller, C. (1999) Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry. J. Chromatogr. A, 854, 23-35.
    • (1999) J. Chromatogr. A , vol.854 , pp. 23-35
    • Zimmer, D.1    Pickard, V.2    Czembor, W.3    Müller, C.4
  • 61
    • 0035114981 scopus 로고    scopus 로고
    • Direct analysis of crude plasma samples by turbulent flow chromatography/tandem mass spectrometry
    • Chassaing, C., Luckwell, J., Macrae, P., Saunders, K., Wright, P. & Venn, R. (2001) Direct analysis of crude plasma samples by turbulent flow chromatography/tandem mass spectrometry. Chromatographia, 53, 122-130.
    • (2001) Chromatographia , vol.53 , pp. 122-130
    • Chassaing, C.1    Luckwell, J.2    Macrae, P.3    Saunders, K.4    Wright, P.5    Venn, R.6
  • 62
    • 0036008569 scopus 로고    scopus 로고
    • Generic method for on-line extraction of drug substances in the presence of biological matrices using turbulent flow chromatography
    • Herman, J.L. (2002) Generic method for on-line extraction of drug substances in the presence of biological matrices using turbulent flow chromatography. Rapid Commun. Mass Spectrom., 16, 421-426.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 421-426
    • Herman, J.L.1
  • 63
    • 0036164807 scopus 로고    scopus 로고
    • Direct cocktail analysis of drug discovery compounds in pooled plasma samples using liquid chromatography-tandem mass spectrometry
    • Hsieh, Y., Bryant, M.S., Brisson, J.-M., Ng, K. & Korfmacher,W.A. (2002) Direct cocktail analysis of drug discovery compounds in pooled plasma samples using liquid chromatography-tandem mass spectrometry. J. Chromatogr. B, 767, 353-362.
    • (2002) J. Chromatogr. B , vol.767 , pp. 353-362
    • Hsieh, Y.1    Bryant, M.S.2    Brisson, J.-M.3    Ng, K.4    Korfmacher, W.A.5
  • 64
    • 0037446554 scopus 로고    scopus 로고
    • Direct plasma analysis of drug compounds using monolithic column liquid chromatography and tandem mass spectrometry
    • Hsieh, Y., Wang, G., Wang, Y., Chackalamannil, S. & Korfmacher, W.A. (2003) Direct plasma analysis of drug compounds using monolithic column liquid chromatography and tandem mass spectrometry. Anal. Chem., 75, 1812-1818.
    • (2003) Anal. Chem. , vol.75 , pp. 1812-1818
    • Hsieh, Y.1    Wang, G.2    Wang, Y.3    Chackalamannil, S.4    Korfmacher, W.A.5
  • 65
    • 20044382081 scopus 로고    scopus 로고
    • Recent developments in on-line SPE for HPLC and LC-MS in bioanalysis
    • Advanstar Communications, Chester
    • Koster, E. & Ooms, B. (2001) Recent developments in on-line SPE for HPLC and LC-MS in bioanalysis. LC-GC Europe Guide to LC-MS, pp. 55-57. Advanstar Communications, Chester.
    • (2001) LC-GC Europe Guide to LC-MS , pp. 55-57
    • Koster, E.1    Ooms, B.2
  • 66
    • 84949750116 scopus 로고    scopus 로고
    • Denaturing solid-phase extraction for reduced protein interference in bioanalytical SPE-LC-MS
    • Koster, E., Ringeling, P. & Ooms, B. (2002) Denaturing solid-phase extraction for reduced protein interference in bioanalytical SPE-LC-MS. LC-GC Europe (The Applications Book), pp. 28-32.
    • (2002) LC-GC Europe (The Applications Book , pp. 28-32
    • Koster, E.1    Ringeling, P.2    Ooms, B.3
  • 67
    • 0038822131 scopus 로고    scopus 로고
    • Directions in discovery: fast, efficient separations in drug discovery-LC-MS analysis using column switching and rapid gradients
    • Needham, S.R. (2000) Directions in discovery: fast, efficient separations in drug discovery-LC-MS analysis using column switching and rapid gradients LC-GC, 18, 1156-1161.
    • (2000) LC-GC , vol.18 , pp. 1156-1161
    • Needham, S.R.1
  • 68
    • 0035100495 scopus 로고    scopus 로고
    • Ultra-fast gradient vs. fast isocratic chromatography in bioanalytical quantification by liquid chromatography/tandem mass spectrometry
    • Romanyshyn, L., Tiller, P.R., Alvaro, R., Pereira, A. & Hop, C.E.C.A. (2001) Ultra-fast gradient vs. fast isocratic chromatography in bioanalytical quantification by liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom., 15, 313-319.
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 313-319
    • Romanyshyn, L.1    Tiller, P.R.2    Alvaro, R.3    Pereira, A.4    Hop, C.E.C.A.5
  • 69
    • 0032896493 scopus 로고    scopus 로고
    • The need for adequate chromatographic separation in the quantitative determination of drugs in biological samples by high performance liquid chromatography with tandem mass spectrometry
    • Jemal. M. & Xia, Y.-Q. (1999) The need for adequate chromatographic separation in the quantitative determination of drugs in biological samples by high performance liquid chromatography with tandem mass spectrometry. Rapid Commun. Mass Spectrom., 13, 97-106.
    • (1999) Rapid Commun. Mass Spectrom. , vol.13 , pp. 97-106
    • Jemal, M.1    Xia, Y.-Q.2
  • 70
    • 0036006588 scopus 로고    scopus 로고
    • Description and validation of a staggered parallel high performance liquid chromatography system for good laboratory practice level quantitative analysis by liquid chromatography/tandem mass spectrometry
    • King, R.C., Miller-Stein, C., Magiera, D.J. & Brann, J. (2002) Description and validation of a staggered parallel high performance liquid chromatography system for good laboratory practice level quantitative analysis by liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom., 16, 43-52.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 43-52
    • King, R.C.1    Miller-Stein, C.2    Magiera, D.J.3    Brann, J.4
  • 71
    • 0035870154 scopus 로고    scopus 로고
    • Evaluation of a four-channel multiplexed electrospray triple quadrupole mass spectrometer for the simultaneous validation of LC/MS/MS methods in four different preclinical matrixes
    • Yang, L., Mann, T.D., Little, D.,Wu, N., Clement, R.P. & Rudewicz, P.J. (2001) Evaluation of a four-channel multiplexed electrospray triple quadrupole mass spectrometer for the simultaneous validation of LC/MS/MS methods in four different preclinical matrixes. Anal. Chem., 73, 1740-1747.
    • (2001) Anal. Chem. , vol.73 , pp. 1740-1747
    • Yang, L.1    Mann, T.D.2    Little, D.3    Wu, N.4    Clement, R.P.5    Rudewicz, P.J.6
  • 72
    • 0036001224 scopus 로고    scopus 로고
    • High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis:30 seconds per sample from plasma
    • Deng, Y., Wu, J.-T., Lloyd, T.L., Chi, C.L., Olah, T.V. & Unger, S.E. (2002) High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis:30 seconds per sample from plasma. Rapid Commun. Mass Spectrom., 16, 1116-1123.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 1116-1123
    • Deng, Y.1    Wu, J.-T.2    Lloyd, T.L.3    Chi, C.L.4    Olah, T.V.5    Unger, S.E.6
  • 73
    • 0035326323 scopus 로고    scopus 로고
    • Simultaneous screen for microsomal stability and metabolite profile by direct injection turbulent-laminar flow LC-LC and automated tandem mass spectrometry
    • Lim, H.K., Chan, K.W., Sisenwine, S. & Scatina, J.A. (2001) Simultaneous screen for microsomal stability and metabolite profile by direct injection turbulent-laminar flow LC-LC and automated tandem mass spectrometry. Anal. Chem., 73, 2140-2146.
    • (2001) Anal. Chem. , vol.73 , pp. 2140-2146
    • Lim, H.K.1    Chan, K.W.2    Sisenwine, S.3    Scatina, J.A.4
  • 74
    • 0036007823 scopus 로고    scopus 로고
    • In vitro metabolite identification using fast gradient high performance liquid chromatography combined with tandem mass spectrometry
    • Hop, C.E.C.A., Tiller, P.R. & Romanyshyn, L. (2002) In vitro metabolite identification using fast gradient high performance liquid chromatography combined with tandem mass spectrometry. Rapid Commun. Mass Spectrom., 16, 212-219.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 212-219
    • Hop, C.E.C.A.1    Tiller, P.R.2    Romanyshyn, L.3
  • 75
    • 0035032944 scopus 로고    scopus 로고
    • High throughput analysis in drug discovery:application of liquid chromatography/ion-trap mass spectrometry for simultaneous cassette analysis of _-1a antagonists and their metabolites in mouse plasma
    • Cai, Z., Han, C., Harrelson, S., Fung, E. & Sinhababu, A.K. (2001) High throughput analysis in drug discovery:application of liquid chromatography/ion-trap mass spectrometry for simultaneous cassette analysis of _-1a antagonists and their metabolites in mouse plasma. Rapid Commun. Mass Spectrom., 15, 546-550.
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 546-550
    • Cai, Z.1    Han, C.2    Harrelson, S.3    Fung, E.4    Sinhababu, A.K.5
  • 76
    • 0035983382 scopus 로고    scopus 로고
    • Liquid, chromatography/tanden mass spectrometric quantification with metabolite screening as a strategy to enhance the early drug discovery process
    • Tiller, P.R. & Romanyshyn, L.A. (2002) Liquid, chromatography/tanden mass spectrometric quantification with metabolite screening as a strategy to enhance the early drug discovery process. Rapid Commun. Mass Spectrom., 16, 1225-1231.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 1225-1231
    • Tiller, P.R.1    Romanyshyn, L.A.2
  • 77
    • 0035416421 scopus 로고    scopus 로고
    • SystematicLC/MSmetabolite identification in drug discovery
    • Clarke, N.J., Rindgen, D.,Korfmacher,W.A.&Cox, K.A. (2001) SystematicLC/MSmetabolite identification in drug discovery. Anal. Chem., 73, 430A-439A.
    • (2001) Anal. Chem. , vol.73 , pp. 430A-439A
    • Clarke, N.J.1    Rindgen, D.2    Korfmacher, W.A.3    Cox, A.K.4
  • 78
    • 0037649064 scopus 로고    scopus 로고
    • Liquid chromatography/atmospheric pressure ionization-mass spectrometry in drug metabolism studies
    • Kostiainen, R., Kotiaho, T., Kuuranne, T. & Auriola, S. (2003) Liquid chromatography/atmospheric pressure ionization-mass spectrometry in drug metabolism studies. J. Mass Spectrom., 38, 357-372.
    • (2003) J. Mass Spectrom. , vol.38 , pp. 357-372
    • Kostiainen, R.1    Kotiaho, T.2    Kuuranne, T.3    Auriola, S.4
  • 79
    • 0034044068 scopus 로고    scopus 로고
    • Bioreactor systems in drug metabolism: synthesis of cytochrome P450-generated metabolites
    • Rushmore, T.H., Reider, P.J., Slaughter. D., Assang, C. & Shou, M. (2000) Bioreactor systems in drug metabolism: synthesis of cytochrome P450-generated metabolites. Metabolic Eng., 2, 115-125.
    • (2000) Metabolic Eng. , vol.2 , pp. 115-125
    • Rushmore, T.H.1    Reider, P.J.2    Slaughter, D.3    Assang, C.4    Shou, M.5
  • 80
    • 0034711479 scopus 로고    scopus 로고
    • Solid-phase microextraction in biomedical analysis
    • Ulrich, S. (2000) Solid-phase microextraction in biomedical analysis. J. Chromatogr. A, 902, 167-194.
    • (2000) J. Chromatogr. A , vol.902 , pp. 167-194
    • Ulrich, S.1
  • 81
    • 0032952578 scopus 로고    scopus 로고
    • The use of preparative highperformance liquid chromatography with tandem mass spectrometric directed fraction collection for the isolation and characterization of drug metabolites in urine by nuclear magnetic resonance spectroscopy and liquid chromatography/sequential mass spectrometry
    • Plumb, R.S., Ayrton, J., Dear, G.J., Sweatman, B.C. & Ismail, I.M. (1999) The use of preparative highperformance liquid chromatography with tandem mass spectrometric directed fraction collection for the isolation and characterization of drug metabolites in urine by nuclear magnetic resonance spectroscopy and liquid chromatography/sequential mass spectrometry. Rapid Commun. Mass Spectrom., 13, 845-854.
    • (1999) Rapid Commun. Mass Spectrom. , vol.13 , pp. 845-854
    • Plumb, R.S.1    Ayrton, J.2    Dear, G.J.3    Sweatman, B.C.4    Ismail, I.M.5
  • 83
    • 0033835592 scopus 로고    scopus 로고
    • Hyphenated HPLC-NMR and its application in drug discovery
    • Peng, S.X. (2000) Hyphenated HPLC-NMR and its application in drug discovery. Biomed. Chromatogr., 14, 430-441.
    • (2000) Biomed. Chromatogr. , vol.14 , pp. 430-441
    • Peng, S.X.1
  • 84
    • 0036179894 scopus 로고    scopus 로고
    • The potential of serially coupled alkyl-bonded silica monolithic columns for high resolution separations of pharmaceutical compounds in biological fluids
    • Dear, G.J., Mallett, D.N., Higton, D.M., Roberts, A.D., Bird, S.A., Young, H., Plumb. R.S. & Ismail, I. M. (2002) The potential of serially coupled alkyl-bonded silica monolithic columns for high resolution separations of pharmaceutical compounds in biological fluids. Chromatographia, 55, 177-184.
    • (2002) Chromatographia , vol.55 , pp. 177-184
    • Dear, G.J.1    Mallett, D.N.2    Higton, D.M.3    Roberts, A.D.4    Bird, S.A.5    Young, H.6    Plumb, S.R.7    Ismail, I.M.8
  • 85
    • 0033669518 scopus 로고    scopus 로고
    • On-line sample preparation system using column-switching HPLC for the structure elucidation of compounds in mixtures by NMR
    • Yokoyama, Y., Kishi, N., Tanaka, M. & Asakawa, N. (2000) On-line sample preparation system using column-switching HPLC for the structure elucidation of compounds in mixtures by NMR. Anal. Sci., 16, 1183-1188.
    • (2000) Anal. Sci. , vol.16 , pp. 1183-1188
    • Yokoyama, Y.1    Kishi, N.2    Tanaka, M.3    Asakawa, N.4
  • 86
  • 87
    • 0034652244 scopus 로고    scopus 로고
    • Quantification and rapid metabolite identification in drug discovery using API time-of-flight LC/MS
    • Zhang, N., Fountain, S.T., Bi, H. & Rossi, D.T. (2000) Quantification and rapid metabolite identification in drug discovery using API time-of-flight LC/MS. Anal. Chem., 72, 800-806.
    • (2000) Anal. Chem. , vol.72 , pp. 800-806
    • Zhang, N.1    Fountain, S.T.2    Bi, H.3    Rossi, D.T.4
  • 88
    • 0035298747 scopus 로고    scopus 로고
    • High-performance liquid chromatography linked to inductively coupled plasma mass spectrometry and orthogonal acceleration time-of-flight mass spectrometry for the simultaneous detection and identification of metabolites of 2-bromo-4-trifluoromethyl-[13C]-acetanilide in rat urine
    • Nicholson, J.K., Lindon, J.C., Scarfe, G.B., Wilson, I.D., Abou-Shakra, F., Sage., A.B. & Castro-Perez, J. (2001) High-performance liquid chromatography linked to inductively coupled plasma mass spectrometry and orthogonal acceleration time-of-flight mass spectrometry for the simultaneous detection and identification of metabolites of 2-bromo-4-trifluoromethyl-[13C]-acetanilide in rat urine. Anal. Chem., 73, 1491-1494.
    • (2001) Anal. Chem. , vol.73 , pp. 1491-1494
    • Nicholson, J.K.1    Lindon, J.C.2    Scarfe, G.B.3    Wilson, I.D.4    Abou-Shakra, F.5    Sage, B.A.6    Castro-Perez, J.7
  • 89
    • 0035543764 scopus 로고    scopus 로고
    • The potential of 19F NMR spectroscopy for rapid screening of cell cultures for models of mammalian drug metabolism
    • Corcoran, O., Lindon, J.C., Hall, R., Ismail, I.M, & Nicholson, J.K. (2001) The potential of 19F NMR spectroscopy for rapid screening of cell cultures for models of mammalian drug metabolism. Analyst, 126, 2103-2106.
    • (2001) Analyst , vol.126 , pp. 2103-2106
    • Corcoran, O.1    Lindon, J.C.2    Hall, R.3    Ismail, I.M.4    Nicholson, J.K.5
  • 90
    • 0034332544 scopus 로고    scopus 로고
    • Fluorine nuclear magnetic resonance, a privileged tool for metabolic studies of fluoropyrimidine drugs
    • Martino, R., Malet-Martino, M. & Gilard, V. (2000) Fluorine nuclear magnetic resonance, a privileged tool for metabolic studies of fluoropyrimidine drugs. Current Drug Metab., 1, 271-303.
    • (2000) Current Drug Metab. , vol.1 , pp. 271-303
    • Martino, R.1    Malet-Martino, M.2    Gilard, V.3
  • 91
    • 0033799309 scopus 로고    scopus 로고
    • Evaluation of automated single mass spectrometry to tanden mass spectrometry function switching for comprehensive drug profiling analysis using a quadrupole timeof-flight mass spectrometer
    • Decaestecker, T.N., Clauwaert, K.M., Van Bocxlaer, J.F., Lambert, W.E., Van den Eeckhout, E.G., Van Peteghem, C.H. & De Leenheer, A.P. (2000) Evaluation of automated single mass spectrometry to tanden mass spectrometry function switching for comprehensive drug profiling analysis using a quadrupole timeof-flight mass spectrometer. Rapid Commun. Mass Spectrom., 14, 1787-1792.
    • (2000) Rapid Commun. Mass Spectrom. , vol.14 , pp. 1787-1792
    • Decaestecker, T.N.1    Clauwaert, K.M.2    Van Bocxlaer, F.J.3    Lambert, W.E.4    Van den Eeckhout, G.E.5    Van Peteghem, H.C.6    De Leenheer, P.A.7
  • 92
    • 0036605551 scopus 로고    scopus 로고
    • Application of semi-automated metabolite identification software in the drug discovery process for rapid identification of metabolites and the cytochrome P450 enzymes responsible for their formation
    • Ramanathan, R., McKenzie, D.L., Tugnait, M. & Siebenaler, K. (2002) Application of semi-automated metabolite identification software in the drug discovery process for rapid identification of metabolites and the cytochrome P450 enzymes responsible for their formation. J. Pharm. Biomed. Anal., 28, 945-951.
    • (2002) J. Pharm. Biomed. Anal. , vol.28 , pp. 945-951
    • Ramanathan, R.1    McKenzie, D.L.2    Tugnait, M.3    Siebenaler, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.