-
1
-
-
84856212837
-
Evolution of extraglottic airway: A review of its history, applications, and practical tips for success
-
M. R. Hernandez, P. A. Klock Jr., and A. Ovassapian, "Evolution of extraglottic airway: a review of its history, applications, and practical tips for success, " Anesthesia and Analgesia, vol. 114, no. 2, pp. 349-368, 2012.
-
(2012)
Anesthesia and Analgesia
, vol.114
, Issue.2
, pp. 349-368
-
-
Hernandez, M.R.1
Klock, P.A.2
Ovassapian, A.3
-
2
-
-
6444223709
-
A proposed classification and scoring system for supraglottic sealing airways: A brief review
-
D. M. Miller, "A proposed classification and scoring system for supraglottic sealing airways: a brief review, " Anesthesia and Analgesia, vol. 99, no. 5, pp. 1553-1559, 2004.
-
(2004)
Anesthesia and Analgesia
, vol.99
, Issue.5
, pp. 1553-1559
-
-
Miller, D.M.1
-
3
-
-
84929942503
-
Airway management evolution-in a search for an ideal extraglottic airway device
-
P. Michálek and D. M. Miller, "Airway management evolution-in a search for an ideal extraglottic airway device, " Prague Medical Report, vol. 115, no. 3-4, pp. 87-103, 2014.
-
(2014)
Prague Medical Report
, vol.115
, Issue.3-4
, pp. 87-103
-
-
Michálek, P.1
Miller, D.M.2
-
4
-
-
0345539354
-
The pharyngeal bulb gasway: A new aid in cyclopropane anesthesia
-
B. C. Leech, "The pharyngeal bulb gasway: a new aid in cyclopropane anesthesia, " Current Researches in Anesthesia & Analgesia, vol. 16, no. 1, pp. 22-25, 1937.
-
(1937)
Current Researches in Anesthesia & Analgesia
, vol.16
, Issue.1
, pp. 22-25
-
-
Leech, B.C.1
-
5
-
-
0020595084
-
The laryngeal mask-a new concept in airway management
-
A. I. J. Brain, "The laryngeal mask-a new concept in airway management, " British Journal of Anaesthesia, vol. 55, no. 8, pp. 801-805, 1983.
-
(1983)
British Journal of Anaesthesia
, vol.55
, Issue.8
, pp. 801-805
-
-
Brain, A.I.J.1
-
6
-
-
84864444241
-
Use of intubation introducers through a supraglottic airway to facilitate tracheal intubation: A brief review
-
D. T. Wong, J. J. Yang, H. Y. Mak, and N. Jagannathan, "Use of intubation introducers through a supraglottic airway to facilitate tracheal intubation: a brief review, " Canadian Journal of Anesthesia, vol. 59, no. 7, pp. 704-715, 2012.
-
(2012)
Canadian Journal of Anesthesia
, vol.59
, Issue.7
, pp. 704-715
-
-
Wong, D.T.1
Yang, J.J.2
Mak, H.Y.3
Jagannathan, N.4
-
7
-
-
84897871958
-
Oxygenation, ventilation, and airway management in out-ofhospital cardiac arrest: A review
-
Article ID376871
-
T. Henlin, P. Michalek, T. Tyll, J. D. Hinds, and M. Dobias, "Oxygenation, ventilation, and airway management in out-ofhospital cardiac arrest: a review, " BioMed Research International, vol. 2014, Article ID376871, 11 pages, 2014.
-
(2014)
BioMed Research International
, vol.2014
, pp. 11
-
-
Henlin, T.1
Michalek, P.2
Tyll, T.3
Hinds, J.D.4
Dobias, M.5
-
8
-
-
78751509215
-
National census of airway management techniques used for anaesthesia in the UK: First phase of the Fourth National Audit Project at the Royal College of Anaesthetists
-
N. M. Woodall and T. M. Cook, "National census of airway management techniques used for anaesthesia in the UK: first phase of the Fourth National Audit Project at the Royal College of Anaesthetists, " British Journal of Anaesthesia, vol. 106, no. 2, pp. 266-271, 2011.
-
(2011)
British Journal of Anaesthesia
, vol.106
, Issue.2
, pp. 266-271
-
-
Woodall, N.M.1
Cook, T.M.2
-
9
-
-
79954538887
-
Major complications of airway management in the UK: Results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia
-
T. M. Cook, N. Woodall, C. Frerk, and Fourth National Audit Project, "Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia, " British Journal of Anaesthesia, vol. 106, no. 5, pp. 617-631, 2011.
-
(2011)
British Journal of Anaesthesia
, vol.106
, Issue.5
, pp. 617-631
-
-
Cook, T.M.1
Woodall, N.2
Frerk, C.3
-
10
-
-
84880016535
-
Thinking twice before using the LMA for obese and older patients-a prospective observational study
-
article 283
-
G. Cheon, S. Siddiqui, T. Lim, et al., "Thinking twice before using the LMA for obese and older patients-a prospective observational study, " Journal of Anesthesia and Clinical Research, vol. 4, no. 2, article 283, 2013.
-
(2013)
Journal of Anesthesia and Clinical Research
, vol.4
, Issue.2
-
-
Cheon, G.1
Siddiqui, S.2
Lim, T.3
-
11
-
-
0034768602
-
Use of the intubating lma-fastrach in 254 patients with difficult-to-manage airways
-
D. Z. Ferson, W. H. Rosenblatt, M. J. Johansen, I. Osborn, and A. Ovassapian, "Use of the intubating lma-fastrach in 254 patients with difficult-to-manage airways, " Anesthesiology, vol. 95, no. 5, pp. 1175-1181, 2001.
-
(2001)
Anesthesiology
, vol.95
, Issue.5
, pp. 1175-1181
-
-
Ferson, D.Z.1
Rosenblatt, W.H.2
Johansen, M.J.3
Osborn, I.4
Ovassapian, A.5
-
12
-
-
65349101139
-
The LMA CTrach in patients with difficult airways
-
E. H. Liu, R. Wender, and A. J. Goldman, "The LMA CTrach in patients with difficult airways, " Anesthesiology, vol. 110, no. 4, pp. 941-943, 2009.
-
(2009)
Anesthesiology
, vol.110
, Issue.4
, pp. 941-943
-
-
Liu, E.H.1
Wender, R.2
Goldman, A.J.3
-
13
-
-
84895264187
-
-
Nova Biomedical, NewYork, NY, USA
-
P. Michalek and W. Donaldson, The I-Gel Supraglottic Airway, Nova Biomedical, NewYork, NY, USA, 2013.
-
(2013)
The I-Gel Supraglottic Airway
-
-
Michalek, P.1
Donaldson, W.2
-
14
-
-
5444234281
-
Editorial II: Who is at increased risk of pulmonary aspiration?
-
T. Asai, "Editorial II: who is at increased risk of pulmonary aspiration?" British Journal of Anaesthesia, vol. 93, no. 4, pp. 497-500, 2004.
-
(2004)
British Journal of Anaesthesia
, vol.93
, Issue.4
, pp. 497-500
-
-
Asai, T.1
-
15
-
-
0032961036
-
Aspiration during anaesthesia: A review of 133 cases from the Australian Anaesthetic Incident Monitoring Study (AIMS)
-
M. T. Kluger and T. G. Short, "Aspiration during anaesthesia: a review of 133 cases from the Australian Anaesthetic Incident Monitoring Study (AIMS), "Anaesthesia, vol. 54, no. 1, pp. 19-26, 1999.
-
(1999)
Anaesthesia
, vol.54
, Issue.1
, pp. 19-26
-
-
Kluger, M.T.1
Short, T.G.2
-
16
-
-
0025270124
-
Adverse respiratory events in anesthesia: A closed claims analysis
-
R. A. Caplan, K. L. Posner, R. J. Ward, and F. W. Cheney, "Adverse respiratory events in anesthesia: a closed claims analysis, " Anesthesiology, vol. 72, no. 5, pp. 828-833, 1990.
-
(1990)
Anesthesiology
, vol.72
, Issue.5
, pp. 828-833
-
-
Caplan, R.A.1
Posner, K.L.2
Ward, R.J.3
Cheney, F.W.4
-
17
-
-
84871201466
-
Complications and failure of airway management
-
T. M. Cook and S. R. Macdougall-Davis, "Complications and failure of airway management, " British Journal of Anaesthesia, vol. 109, no. 1, pp. i68-i85, 2012.
-
(2012)
British Journal of Anaesthesia
, vol.109
, Issue.1
, pp. i68-i85
-
-
Cook, T.M.1
Macdougall-Davis, S.R.2
-
18
-
-
0024602886
-
The laryngeal mask airway. A study of 100 patients during spontaneous breathing
-
P. M. Brodrick, N. R. Webster, and J. F. Nunn, "The laryngeal mask airway. A study of 100 patients during spontaneous breathing, " Anaesthesia, vol. 44, no. 3, pp. 238-241, 1989.
-
(1989)
Anaesthesia
, vol.44
, Issue.3
, pp. 238-241
-
-
Brodrick, P.M.1
Webster, N.R.2
Nunn, J.F.3
-
19
-
-
0025614668
-
Aspiration pneumonia and the laryngeal mask airway
-
R. M. Griffin and I. S. Hatcher, "Aspiration pneumonia and the laryngeal mask airway, " Anaesthesia, vol. 45, no. 12, pp. 1039-1040, 1990.
-
(1990)
Anaesthesia
, vol.45
, Issue.12
, pp. 1039-1040
-
-
Griffin, R.M.1
Hatcher, I.S.2
-
20
-
-
0026517542
-
Vomiting and aspiration pneumonitis with the laryngeal mask airway
-
G. M. Nanji and J. R. Maltby, "Vomiting and aspiration pneumonitis with the laryngeal mask airway, " Canadian Journal of Anaesthesia, vol. 39, no. 1, pp. 69-70, 1992.
-
(1992)
Canadian Journal of Anaesthesia
, vol.39
, Issue.1
, pp. 69-70
-
-
Nanji, G.M.1
Maltby, J.R.2
-
21
-
-
0026784611
-
Regurgitation and the laryngealmask
-
A. I. J. Brain, "Regurgitation and the laryngealmask, " Canadian Journal of Anaesthesia, vol. 39, no. 7, pp. 743-744, 1992.
-
(1992)
Canadian Journal of Anaesthesia
, vol.39
, Issue.7
, pp. 743-744
-
-
Brain, A.I.J.1
-
22
-
-
0029030466
-
The incidence of aspiration associated with the laryngeal mask airway: A meta-analysis of published literature
-
J. R. Brimacombe and A. Berry, "The incidence of aspiration associated with the laryngeal mask airway: a meta-analysis of published literature, " Journal of Clinical Anesthesia, vol. 7, no. 4, pp. 297-305, 1995.
-
(1995)
Journal of Clinical Anesthesia
, vol.7
, Issue.4
, pp. 297-305
-
-
Brimacombe, J.R.1
Berry, A.2
-
23
-
-
0030028038
-
Survey of laryngeal mask airway usage in 11, 910 patients: Safety and efficacy for conventional and nonconventional usage
-
C. Verghese and J. R. Brimacombe, "Survey of laryngeal mask airway usage in 11, 910 patients: safety and efficacy for conventional and nonconventional usage, " Anesthesia and Analgesia, vol. 82, no. 1, pp. 129-133, 1996.
-
(1996)
Anesthesia and Analgesia
, vol.82
, Issue.1
, pp. 129-133
-
-
Verghese, C.1
Brimacombe, J.R.2
-
24
-
-
70449673109
-
Risk of pulmonary aspiration with laryngeal mask airway and tracheal tube: Analysis on 65 procedures with positive pressure ventilation
-
A. Bernardini and G. Natalini, "Risk of pulmonary aspiration with laryngeal mask airway and tracheal tube: analysis on 65 procedures with positive pressure ventilation, " Anaesthesia, vol. 64, no. 12, pp. 1289-1294, 2009.
-
(2009)
Anaesthesia
, vol.64
, Issue.12
, pp. 1289-1294
-
-
Bernardini, A.1
Natalini, G.2
-
25
-
-
0027514768
-
Clinical significance of pulmonary aspiration during the perioperative period
-
M. A. Warner, M. E. Warner, and J. G. Weber, "Clinical significance of pulmonary aspiration during the perioperative period, " Anesthesiology, vol. 78, no. 1, pp. 56-62, 1993.
-
(1993)
Anesthesiology
, vol.78
, Issue.1
, pp. 56-62
-
-
Warner, M.A.1
Warner, M.E.2
Weber, J.G.3
-
26
-
-
84904393022
-
Aspiration under anaesthesia: Risk assessment and decision-making
-
M. Robinson and A. Davidson, "Aspiration under anaesthesia: risk assessment and decision-making, " Continuing Education in Anaesthesia, Critical Care&Pain, vol. 14, no. 4, pp. 171-175, 2014.
-
(2014)
Continuing Education in Anaesthesia, Critical Care & Pain
, vol.14
, Issue.4
, pp. 171-175
-
-
Robinson, M.1
Davidson, A.2
-
27
-
-
5444266057
-
Aspiration and the laryngeal mask airway: Three cases and a review of the literature
-
C. Keller, J. Brimacombe, J. Bittersohl, P. Lirk, and A. von Goedecke, "Aspiration and the laryngeal mask airway: three cases and a review of the literature, " British Journal of Anaesthesia, vol. 93, no. 4, pp. 579-582, 2004.
-
(2004)
British Journal of Anaesthesia
, vol.93
, Issue.4
, pp. 579-582
-
-
Keller, C.1
Brimacombe, J.2
Bittersohl, J.3
Lirk, P.4
Von Goedecke, A.5
-
28
-
-
24944570669
-
Aspiration and death associated with the use of the laryngeal mask airway
-
C. Cook and A. R. Gande, "Aspiration and death associated with the use of the laryngeal mask airway, " British Journal of Anaesthesia, vol. 95, no. 3, pp. 425-426, 2005.
-
(2005)
British Journal of Anaesthesia
, vol.95
, Issue.3
, pp. 425-426
-
-
Cook, C.1
Gande, A.R.2
-
29
-
-
0038024152
-
Storage capacities of the laryngeal mask and laryngeal tube compared and their relevance to aspiration risk during positive pressure ventilation
-
D. M. Miller and D. Light, "Storage capacities of the laryngeal mask and laryngeal tube compared and their relevance to aspiration risk during positive pressure ventilation, " Anesthesia and Analgesia, vol. 96, no. 6, pp. 1821-1822, 2003.
-
(2003)
Anesthesia and Analgesia
, vol.96
, Issue.6
, pp. 1821-1822
-
-
Miller, D.M.1
Light, D.2
-
30
-
-
22944491457
-
An evaluation of the Cobra PerilaryngealAirway: Study halted after two cases of pulmonary aspiration
-
T. M. Cook and J. M. Lowe, "An evaluation of the Cobra PerilaryngealAirway: study halted after two cases of pulmonary aspiration, " Anaesthesia, vol. 60, no. 8, pp. 791-796, 2005.
-
(2005)
Anaesthesia
, vol.60
, Issue.8
, pp. 791-796
-
-
Cook, T.M.1
Lowe, J.M.2
-
31
-
-
0036274658
-
Protection against aspiration with the Proseal laryngeal mask airway
-
K. K. de Silva and P. Young, "Protection against aspiration with the Proseal laryngeal mask airway, " Anaesthesia and Intensive Care, vol. 30, no. 3, p. 391, 2002.
-
(2002)
Anaesthesia and Intensive Care
, vol.30
, Issue.3
, pp. 391
-
-
De Silva, K.K.1
Young, P.2
-
32
-
-
0037328798
-
A case of aspiration using the ProSeal LMA
-
C. K. Koay, "A case of aspiration using the ProSeal LMA, " Anaesthesia and Intensive Care, vol. 31, no. 1, p. 123, 2003.
-
(2003)
Anaesthesia and Intensive Care
, vol.31
, Issue.1
, pp. 123
-
-
Koay, C.K.1
-
33
-
-
0141569673
-
Aspiration of gastric contents during use of a ProSeal laryngeal mask airway secondary to unidentified foldover malposition
-
J. Brimacombe and C. Keller, "Aspiration of gastric contents during use of a ProSeal laryngeal mask airway secondary to unidentified foldover malposition, " Anesthesia and Analgesia, vol. 97, no. 4, pp. 1192-1194, 2003.
-
(2003)
Anesthesia and Analgesia
, vol.97
, Issue.4
, pp. 1192-1194
-
-
Brimacombe, J.1
Keller, C.2
-
34
-
-
84871803375
-
Pulmonary aspiration associated with supraglottic airways: Proseal laryngeal mask airway and I-Gel
-
Y.-H. Kim, "Pulmonary aspiration associated with supraglottic airways: proseal laryngeal mask airway and I-Gel, " Korean Journal of Anesthesiology, vol. 63, no. 6, pp. 489-490, 2012.
-
(2012)
Korean Journal of Anesthesiology
, vol.63
, Issue.6
, pp. 489-490
-
-
Kim, Y.-H.1
-
35
-
-
66249101619
-
Ease of Proseal LaryngealMask Airway insertion and its fibreoptic view after placement using gum elastic bougie: A comparison with conventional techniques
-
S. Taneja, M. Agarwal, J. S. Dali, and G. Agrawal, "Ease of Proseal LaryngealMask Airway insertion and its fibreoptic view after placement using gum elastic bougie: a comparison with conventional techniques, " Anaesthesia and Intensive Care, vol. 37, no. 3, pp. 435-440, 2009.
-
(2009)
Anaesthesia and Intensive Care
, vol.37
, Issue.3
, pp. 435-440
-
-
Taneja, S.1
Agarwal, M.2
Dali, J.S.3
Agrawal, G.4
-
36
-
-
2442647954
-
Ease placement of LMA proseal with a gastric tube inserted
-
V. Martínez-Pons and V. Madrid, "Ease placement of LMA proseal with a gastric tube inserted, " Anesthesia and Analgesia, vol. 98, no. 6, pp. 1816-1817, 2004.
-
(2004)
Anesthesia and Analgesia
, vol.98
, Issue.6
, pp. 1816-1817
-
-
Martínez-Pons, V.1
Madrid, V.2
-
37
-
-
84896737024
-
Suction catheter guided insertion of ProSeal laryngeal mask airway: Experience by untrained physicians
-
V. Perilli, P. Aceto, T. Sacco, N. Martella, M. T. Cazzato, and L. Sollazzi, "Suction catheter guided insertion of ProSeal laryngeal mask airway: experience by untrained physicians, " Indian Journal of Anaesthesia, vol. 58, no. 1, pp. 25-29, 2014.
-
(2014)
Indian Journal of Anaesthesia
, vol.58
, Issue.1
, pp. 25-29
-
-
Perilli, V.1
Aceto, P.2
Sacco, T.3
Martella, N.4
Cazzato, M.T.5
Sollazzi, L.6
-
38
-
-
84867995119
-
Oral gastric tubeguided insertion of the ProSeal laryngeal mask is an easy and noninvasive method for less experienced users
-
T. Nagata, Y. Kishi, H. Tanigami, et al., "Oral gastric tubeguided insertion of the ProSeal laryngeal mask is an easy and noninvasive method for less experienced users, " Journal of Anesthesia, vol. 26, no. 4, pp. 531-535, 2012.
-
(2012)
Journal of Anesthesia
, vol.26
, Issue.4
, pp. 531-535
-
-
Nagata, T.1
Kishi, Y.2
Tanigami, H.3
-
39
-
-
84902125578
-
Comparison of laryngealmask airway Supreme and laryngealmask airway Pro-Seal for controlled ventilation during general anaesthesia in adult patients: Systematic review with meta-analysis
-
S. Maitra, P. Khanna, and D. K. Baidya, "Comparison of laryngealmask airway Supreme and laryngealmask airway Pro-Seal for controlled ventilation during general anaesthesia in adult patients: systematic review with meta-analysis, " European Journal of Anaesthesiology, vol. 31, no. 5, pp. 266-273, 2014.
-
(2014)
European Journal of Anaesthesiology
, vol.31
, Issue.5
, pp. 266-273
-
-
Maitra, S.1
Khanna, P.2
Baidya, D.K.3
-
40
-
-
84864459579
-
The LMA Supreme in 700 parturients undergoing Cesarean delivery: An observational study
-
W. Y. Yao, S. Y. Li, B. L. Sng, Y. Lim, and A. T. H. Sia, "The LMA Supreme in 700 parturients undergoing Cesarean delivery: an observational study, " Canadian Journal ofAnesthesia, vol. 59, no. 7, pp. 648-654, 2012.
-
(2012)
Canadian Journal of Anesthesia
, vol.59
, Issue.7
, pp. 648-654
-
-
Yao, W.Y.1
Li, S.Y.2
Sng, B.L.3
Lim, Y.4
Sia, A.T.H.5
-
41
-
-
40949114936
-
Case series: Protection from aspiration and failure of protection from aspiration with the i-gel airway
-
B. Gibbison, T. M. Cook, and C. Seller, "Case series: protection from aspiration and failure of protection from aspiration with the i-gel airway, " British Journal of Anaesthesia, vol. 31, no. 100, pp. 415-417, 2008.
-
(2008)
British Journal of Anaesthesia
, vol.31
, Issue.100
, pp. 415-417
-
-
Gibbison, B.1
Cook, T.M.2
Seller, C.3
-
42
-
-
44949213760
-
Aspiration recognition with anigel airway
-
G. Liew, B. John, and S. Ahmed, "Aspiration recognition with anigel airway, " Anaesthesia, vol. 63, no. 7, p. 786, 2008.
-
(2008)
Anaesthesia
, vol.63
, Issue.7
, pp. 786
-
-
Liew, G.1
John, B.2
Ahmed, S.3
-
43
-
-
57349166088
-
Oesophageal seal of the novel supralaryngeal airway device I-Gel in comparison with the laryngeal mask airways Classic and ProSeal using a cadaver model
-
W. Schmidbauer, S. Bercker, T. Volk, G. Bogusch, G. Mager, and T. Kerner, "Oesophageal seal of the novel supralaryngeal airway device I-Gel in comparison with the laryngeal mask airways Classic and ProSeal using a cadaver model, " British Journal of Anaesthesia, vol. 102, no. 1, pp. 135-139, 2009.
-
(2009)
British Journal of Anaesthesia
, vol.102
, Issue.1
, pp. 135-139
-
-
Schmidbauer, W.1
Bercker, S.2
Volk, T.3
Bogusch, G.4
Mager, G.5
Kerner, T.6
-
44
-
-
84943245956
-
Time to abandon the vintage laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice
-
T. M. Cook and F. E. Kelly, "Time to abandon the vintage laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice, " British Journal of Anaesthesia, vol. 115, no. 4, pp. 497-499, 2015.
-
(2015)
British Journal of Anaesthesia
, vol.115
, Issue.4
, pp. 497-499
-
-
Cook, T.M.1
Kelly, F.E.2
-
45
-
-
84902243785
-
Complications of airway management
-
P. C. Pacheco-Lopez, L. C. Berkow, A. T. Hillel, and L. M. Akst, "Complications of airway management, " Respiratory Care, vol. 59, no. 6, pp. 1006-1021, 2014.
-
(2014)
Respiratory Care
, vol.59
, Issue.6
, pp. 1006-1021
-
-
Pacheco-Lopez, P.C.1
Berkow, L.C.2
Hillel, A.T.3
Akst, L.M.4
-
46
-
-
84922643973
-
Cranial nerve injuries with supraglottic airway devices: A systematic review of published case reports and series
-
V. Thiruvenkatarajan, R. M. vanWijk, and A. Rajbhoj, "Cranial nerve injuries with supraglottic airway devices: a systematic review of published case reports and series, " Anaesthesia, vol. 70, no. 3, pp. 344-359, 2015.
-
(2015)
Anaesthesia
, vol.70
, Issue.3
, pp. 344-359
-
-
Thiruvenkatarajan, V.1
Van Wijk, R.M.2
Rajbhoj, A.3
-
47
-
-
1142263229
-
Medicolegal claims against anaesthetists: A 20 year study
-
N. M. Cass, "Medicolegal claims against anaesthetists: a 20 year study, " Anaesthesia and Intensive Care, vol. 32, no. 1, pp. 47-58, 2004.
-
(2004)
Anaesthesia and Intensive Care
, vol.32
, Issue.1
, pp. 47-58
-
-
Cass, N.M.1
-
48
-
-
65349158626
-
Perioperative dental considerations for the anesthesiologist
-
J. S. Yasny, "Perioperative dental considerations for the anesthesiologist, " Anesthesia and Analgesia, vol. 108, no. 5, pp. 1564-1573, 2009.
-
(2009)
Anesthesia and Analgesia
, vol.108
, Issue.5
, pp. 1564-1573
-
-
Yasny, J.S.1
-
49
-
-
80455131335
-
Premolar loss following insertion of a classic laryngeal mask airway in a patient in the prone position
-
S.-W. Chau, F.-Y. Wang, C.-W. Wu, et al., "Premolar loss following insertion of a classic laryngeal mask airway in a patient in the prone position, " Journal of Clinical Anesthesia, vol. 23, no. 7, pp. 588-589, 2011.
-
(2011)
Journal of Clinical Anesthesia
, vol.23
, Issue.7
, pp. 588-589
-
-
Chau, S.-W.1
Wang, F.-Y.2
Wu, C.-W.3
-
50
-
-
33749043512
-
Dental damage caused by the intubating laryngeal mask airway
-
T. Asai, "Dental damage caused by the intubating laryngeal mask airway, " Anesthesia & Analgesia, vol. 103, no. 3, p. 785, 2006.
-
(2006)
Anesthesia & Analgesia
, vol.103
, Issue.3
, pp. 785
-
-
Asai, T.1
-
51
-
-
78549276233
-
Comparison of the LMASupreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation
-
W. H. L. Teoh, K. M. Lee, T. Suhitharan, Z. Yahaya, M. M. Teo, and A. T. H. Sia, "Comparison of the LMASupreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation, " Anaesthesia, vol. 65, no. 12, pp. 1173-1179, 2010.
-
(2010)
Anaesthesia
, vol.65
, Issue.12
, pp. 1173-1179
-
-
Teoh, W.H.L.1
Lee, K.M.2
Suhitharan, T.3
Yahaya, Z.4
Teo, M.M.5
Sia, A.T.H.6
-
52
-
-
77958092936
-
Safety an efficacy of insertion of supraglottic devices in anaesthetised patients by first-time users
-
P. Jindal, A. A. Rizvi, G. Khurana, and J. P. Sharma, "Safety an efficacy of insertion of supraglottic devices in anaesthetised patients by first-time users, " Southern African Journal of Anaesthesia and Analgesia, vol. 16, no. 4, pp. 23-26, 2010.
-
(2010)
Southern African Journal of Anaesthesia and Analgesia
, vol.16
, Issue.4
, pp. 23-26
-
-
Jindal, P.1
Rizvi, A.A.2
Khurana, G.3
Sharma, J.P.4
-
53
-
-
77956071238
-
Comparison of clinical performance of I-Gel with LMA-proseal in elective surgeries
-
I. Singh, M. Gupta, and M. Tandon, "Comparison of clinical performance of I-Gel with LMA-proseal in elective surgeries, " Indian Journal of Anaesthesia, vol. 53, no. 3, pp. 302-305, 2009.
-
(2009)
Indian Journal of Anaesthesia
, vol.53
, Issue.3
, pp. 302-305
-
-
Singh, I.1
Gupta, M.2
Tandon, M.3
-
54
-
-
0029912608
-
Dental damage to the laryngeal mask
-
H. A. McLure, "Dental damage to the laryngeal mask, " Anaesthesia, vol. 51, no. 11, pp. 1078-1079, 1996.
-
(1996)
Anaesthesia
, vol.51
, Issue.11
, pp. 1078-1079
-
-
McLure, H.A.1
-
55
-
-
0034114306
-
Visible and occult blood contamination of laryngeal mask airways and tracheal tubes used in adult anaesthesia
-
M. R. J. Parker and C. J. E. Day, "Visible and occult blood contamination of laryngeal mask airways and tracheal tubes used in adult anaesthesia, " Anaesthesia, vol. 55, no. 4, pp. 388-390, 2000.
-
(2000)
Anaesthesia
, vol.55
, Issue.4
, pp. 388-390
-
-
Parker, M.R.J.1
Day, C.J.E.2
-
56
-
-
65349185468
-
Comparison of two insertion techniques of ProSeal laryngeal mask airway: Standard versus 90-degree rotation
-
J.-W. Hwang, H.-P. Park, Y.-J. Lim, S.-H. Do, S.-C. Lee, and Y.-T. Jeon, "Comparison of two insertion techniques of ProSeal laryngeal mask airway: standard versus 90-degree rotation, " Anesthesiology, vol. 110, no. 4, pp. 905-907, 2009.
-
(2009)
Anesthesiology
, vol.110
, Issue.4
, pp. 905-907
-
-
Hwang, J.-W.1
Park, H.-P.2
Lim, Y.-J.3
Do, S.-H.4
Lee, S.-C.5
Jeon, Y.-T.6
-
57
-
-
84929158348
-
Comparisons of clinical performance of guardian laryngeal maskwith laryngealmask airway ProSeal
-
article 69
-
A. K. Pajiyar, Z. Wen, H. Wang, L. Ma, L. Miao, and G. Wang, "Comparisons of clinical performance of guardian laryngeal maskwith laryngealmask airway ProSeal, " BMCAnesthesiology, vol. 15, no. 1, article 69, 2015.
-
(2015)
BMC Anesthesiology
, vol.15
, Issue.1
-
-
Pajiyar, A.K.1
Wen, Z.2
Wang, H.3
Ma, L.4
Miao, L.5
Wang, G.6
-
58
-
-
84862793214
-
A randomised trial comparing the i-gel with the LMA classic in children
-
J.-R. Lee, M.-S. Kim, J.-T. Kim, et al., "A randomised trial comparing the i-gel with the LMA classic in children, " Anaesthesia, vol. 67, no. 6, pp. 606-611, 2012.
-
(2012)
Anaesthesia
, vol.67
, Issue.6
, pp. 606-611
-
-
Lee, J.-R.1
Kim, M.-S.2
Kim, J.-T.3
-
59
-
-
84858332383
-
Directly measured mucosal pressures produced by the i-gelTM and laryngeal mask airway Supreme in paralysed anaesthetised patient
-
S. Eschertzhuber, J. Brimacombe, M. Kaufmann, C. Keller, and W. Tiefenthaler, "Directly measured mucosal pressures produced by the i-gelTM and laryngeal mask airway Supreme in paralysed anaesthetised patient, " Anaesthesia, vol. 67, no. 4, pp. 407-410, 2012.
-
(2012)
Anaesthesia
, vol.67
, Issue.4
, pp. 407-410
-
-
Eschertzhuber, S.1
Brimacombe, J.2
Kaufmann, M.3
Keller, C.4
Tiefenthaler, W.5
-
60
-
-
79960539670
-
Randomized trial comparing the i-gel and Magill tracheal tube with the single-use ILMAand ILMA tracheal tube for fibreoptic-guided intubation in anaesthetized patients with a predicted difficult airway
-
M. Kleine-Brueggeney, L. Theiler, N. Urwyler, A. Vogt, and R. Greif, "Randomized trial comparing the i-gel and Magill tracheal tube with the single-use ILMAand ILMA tracheal tube for fibreoptic-guided intubation in anaesthetized patients with a predicted difficult airway, " British Journal of Anaesthesia, vol. 107, no. 2, pp. 251-257, 2011.
-
(2011)
British Journal of Anaesthesia
, vol.107
, Issue.2
, pp. 251-257
-
-
Kleine-Brueggeney, M.1
Theiler, L.2
Urwyler, N.3
Vogt, A.4
Greif, R.5
-
61
-
-
84858335845
-
LMA Supreme vs i-gel-a comparison of insertion success in novices
-
R. Ragazzi, L. Finessi, I. Farinelli, R. Alvisi, and C. A. Volta, "LMA Supreme vs i-gel-a comparison of insertion success in novices, " Anaesthesia, vol. 67, no. 4, pp. 384-388, 2012.
-
(2012)
Anaesthesia
, vol.67
, Issue.4
, pp. 384-388
-
-
Ragazzi, R.1
Finessi, L.2
Farinelli, I.3
Alvisi, R.4
Volta, C.A.5
-
62
-
-
79960179974
-
Igel vs. AuraOnce laryngeal mask for general anaesthesia with controlled ventilation in paralyzed patients
-
W. Donaldson, A. Abraham, M. Deighan, and P. Michalek, "Igel vs. AuraOnce laryngeal mask for general anaesthesia with controlled ventilation in paralyzed patients, " Biomedical Papers, vol. 155, no. 2, pp. 155-163, 2011.
-
(2011)
Biomedical Papers
, vol.155
, Issue.2
, pp. 155-163
-
-
Donaldson, W.1
Abraham, A.2
Deighan, M.3
Michalek, P.4
-
63
-
-
84863362678
-
Randomised comparison of the AMBU AuraOnce laryngeal mask and the LMA unique laryngeal mask airway in spontaneously breathing adults
-
Article ID 405812
-
D. L. Williams, J. M. Zeng, K. D. Alexander, and D. T. Andrews, "Randomised comparison of the AMBU AuraOnce laryngeal mask and the LMA unique laryngeal mask airway in spontaneously breathing adults, " Anesthesiology Research and Practice, vol. 2012, Article ID 405812, 5 pages, 2012.
-
(2012)
Anesthesiology Research and Practice
, vol.2012
, pp. 5
-
-
Williams, D.L.1
Zeng, J.M.2
Alexander, K.D.3
Andrews, D.T.4
-
64
-
-
33344460878
-
Comparison of the laryngeal mask (LMA) and laryngeal tube (LT) with the new perilaryngeal airway (CobraPLA) in short surgical procedures
-
A. Turan, G. Kaya, O. Koyuncu, B. Karamanlioglu, and Z. Pamukcu, "Comparison of the laryngeal mask (LMA) and laryngeal tube (LT) with the new perilaryngeal airway (CobraPLA) in short surgical procedures, " European Journal of Anaesthesiology, vol. 23, no. 3, pp. 234-238, 2006.
-
(2006)
European Journal of Anaesthesiology
, vol.23
, Issue.3
, pp. 234-238
-
-
Turan, A.1
Kaya, G.2
Koyuncu, O.3
Karamanlioglu, B.4
Pamukcu, Z.5
-
65
-
-
84889671031
-
Comparison of laryngeal mask airway Supreme and laryngeal mask airway ProSeal for laryngopharyngeal trauma and postoperative morbidity in children
-
M. T. Aydogmus, B. Eksioglu, S. Oba, et al., "Comparison of laryngeal mask airway Supreme and laryngeal mask airway ProSeal for laryngopharyngeal trauma and postoperative morbidity in children, " Revista Brasileira de Anestesiologia, vol. 63, no. 6, pp. 445-449, 2013.
-
(2013)
Revista Brasileira de Anestesiologia
, vol.63
, Issue.6
, pp. 445-449
-
-
Aydogmus, M.T.1
Eksioglu, B.2
Oba, S.3
-
66
-
-
80052460377
-
Comparison of streamlined liner of the pharynx airway (SLIPA) with the laryngeal mask airway Proseal for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients
-
A. A. Abdellatif and M. A. Ali, "Comparison of streamlined liner of the pharynx airway (SLIPA) with the laryngeal mask airway Proseal for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients, " Saudi Journal of Anaesthesia, vol. 5, no. 3, pp. 270-276, 2011.
-
(2011)
Saudi Journal of Anaesthesia
, vol.5
, Issue.3
, pp. 270-276
-
-
Abdellatif, A.A.1
Ali, M.A.2
-
67
-
-
33846463415
-
The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA) compared with the conventional laryngeal mask airway in ophthalmic surgery
-
M. Lange, T. Smul, P. Zimmermann, R. Kohlenberger, N. Roewer, and F. Kehl, "The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA) compared with the conventional laryngeal mask airway in ophthalmic surgery, " Anesthesia and Analgesia, vol. 104, no. 2, pp. 431-434, 2007.
-
(2007)
Anesthesia and Analgesia
, vol.104
, Issue.2
, pp. 431-434
-
-
Lange, M.1
Smul, T.2
Zimmermann, P.3
Kohlenberger, R.4
Roewer, N.5
Kehl, F.6
-
68
-
-
84884136093
-
Comparison of the Baska mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery
-
V. Alexiev, A. Ochana, D. Abdelrahman, et al., "Comparison of the Baska mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery, " Anaesthesia, vol. 68, no. 10, pp. 1026-1032, 2013.
-
(2013)
Anaesthesia
, vol.68
, Issue.10
, pp. 1026-1032
-
-
Alexiev, V.1
Ochana, A.2
Abdelrahman, D.3
-
69
-
-
84944254151
-
Comparison of five 2nd-generation supraglottic airway devices for airway management performed by novice military operators
-
Article ID 201898
-
T. Henlin, M. Sotak, P. Kovaricek, T. Tyll, L. Balcarek, and P. Michalek, "Comparison of five 2nd-generation supraglottic airway devices for airway management performed by novice military operators, " BioMed Research International, vol. 2015, Article ID 201898, 8 pages, 2015.
-
(2015)
BioMed Research International
, vol.2015
, pp. 8
-
-
Henlin, T.1
Sotak, M.2
Kovaricek, P.3
Tyll, T.4
Balcarek, L.5
Michalek, P.6
-
70
-
-
84869452065
-
I-gel supraglottic airway in clinical practice: A prospective observational multicentre study
-
L. Theiler, M. Gutzmann, M. Kleine-Brueggeney, N. Urwyler, B. Kaempfen, and R. Greif, "I-gel supraglottic airway in clinical practice: a prospective observational multicentre study, " British Journal of Anaesthesia, vol. 109, no. 6, pp. 990-995, 2012.
-
(2012)
British Journal of Anaesthesia
, vol.109
, Issue.6
, pp. 990-995
-
-
Theiler, L.1
Gutzmann, M.2
Kleine-Brueggeney, M.3
Urwyler, N.4
Kaempfen, B.5
Greif, R.6
-
71
-
-
33744480761
-
Frenular injury during insertion of the ProSeal laryngeal mask airway using the introducer tool technique
-
Z. M. Haris, W. T. Loo, and J. Brimacombe, "Frenular injury during insertion of the ProSeal laryngeal mask airway using the introducer tool technique, " Anesthesia and Analgesia, vol. 102, no. 6, pp. 1906-1907, 2006.
-
(2006)
Anesthesia and Analgesia
, vol.102
, Issue.6
, pp. 1906-1907
-
-
Haris, Z.M.1
Loo, W.T.2
Brimacombe, J.3
-
72
-
-
84895210141
-
Tearing of the lingual frenulum caused by insertion of the ProSeal LMA in a child: A case report
-
M. J. Park, H. S. Kim, J. T. Kim, C. S. Kim, and S. D. Kim, "Tearing of the lingual frenulum caused by insertion of the ProSeal LMA in a child: a case report, " Korean Journal of Anesthesiology, vol. 57, no. 5, p. 644, 2009.
-
(2009)
Korean Journal of Anesthesiology
, vol.57
, Issue.5
, pp. 644
-
-
Park, M.J.1
Kim, H.S.2
Kim, J.T.3
Kim, C.S.4
Kim, S.D.5
-
73
-
-
66349115344
-
Tongue trauma associated with the i-gel supraglottic airway
-
P. Michalek, W. J. Donaldson, and J. D. Hinds, "Tongue trauma associated with the i-gel supraglottic airway, " Anaesthesia, vol. 64, no. 6, p. 692, 2009.
-
(2009)
Anaesthesia
, vol.64
, Issue.6
, pp. 692
-
-
Michalek, P.1
Donaldson, W.J.2
Hinds, J.D.3
-
74
-
-
77449157672
-
Insertion of the i-gel airway obstructed by the tongue
-
S. Taxak and A. Gopinath, "Insertion of the i-gel airway obstructed by the tongue, " Anesthesiology, vol. 112, no. 2, pp. 500-501, 2010.
-
(2010)
Anesthesiology
, vol.112
, Issue.2
, pp. 500-501
-
-
Taxak, S.1
Gopinath, A.2
-
75
-
-
84908505969
-
Uvulitis following general anaesthesia
-
Article ID A1841
-
K. Ziahosseini, S. Ali, R. Simo, and R. Malhotra, "Uvulitis following general anaesthesia, " BMJ Case Reports, vol. 2014, Article ID A1841, 2014.
-
(2014)
BMJ Case Reports
, vol.2014
-
-
Ziahosseini, K.1
Ali, S.2
Simo, R.3
Malhotra, R.4
-
76
-
-
80051482357
-
Lingual ischemia from prolonged insertion of a Fastrach laryngealmask airway
-
N. S. Gerstein, D. Braude, J. S. Harding, and A. Douglas, "Lingual ischemia from prolonged insertion of a Fastrach laryngealmask airway, "Western Journal of EmergencyMedicine, vol. 12, no. 1, pp. 124-127, 2011.
-
(2011)
Western Journal of Emergency Medicine
, vol.12
, Issue.1
, pp. 124-127
-
-
Gerstein, N.S.1
Braude, D.2
Harding, J.S.3
Douglas, A.4
-
77
-
-
84954183343
-
Tongue swelling and necrosis after brain tumor surgery
-
G. Britz, S. Nimjee, D. Wright, A. Agrawal, D. McDonagh, and A. Husain, "Tongue swelling and necrosis after brain tumor surgery, " Asian Journal of Neurosurgery, vol. 7, no. 4, pp. 214-216, 2012.
-
(2012)
Asian Journal of Neurosurgery
, vol.7
, Issue.4
, pp. 214-216
-
-
Britz, G.1
Nimjee, S.2
Wright, D.3
Agrawal, A.4
McDonagh, D.5
Husain, A.6
-
78
-
-
84942307917
-
A pilot evaluation of the 3gLM-R-a new supraglottic airway device
-
P. Michalek, B. Jindrova, P. Kriz, M. Stritesky, and M. Sedlar, "A pilot evaluation of the 3gLM-R-a new supraglottic airway device, " Advances inMedical Sciences, vol. 60, no. 2, pp. 186-190, 2015.
-
(2015)
Advances in Medical Sciences
, vol.60
, Issue.2
, pp. 186-190
-
-
Michalek, P.1
Jindrova, B.2
Kriz, P.3
Stritesky, M.4
Sedlar, M.5
-
79
-
-
0031896170
-
Pulmonary aspiration of blood following traumatic laryngeal mask airway insertion
-
A. Norton, J. Germonpré, and T. Semple, "Pulmonary aspiration of blood following traumatic laryngeal mask airway insertion, " Anaesthesia and Intensive Care, vol. 26, no. 2, pp. 213-215, 1998.
-
(1998)
Anaesthesia and Intensive Care
, vol.26
, Issue.2
, pp. 213-215
-
-
Norton, A.1
-
80
-
-
77749295244
-
Case report: Severe laryngeal hemorrhage after withdrawal of a size 5 I-gel in elective surgery
-
G. Dangelser, A. S. Dincq, G. Lawson, and E. Collard, "Case report: severe laryngeal hemorrhage after withdrawal of a size 5 I-gel in elective surgery, " Acta Anaesthesiologica Belgica, vol. 60, no. 4, pp. 255-257, 2009.
-
(2009)
Acta Anaesthesiologica Belgica
, vol.60
, Issue.4
, pp. 255-257
-
-
Dangelser, G.1
Dincq, A.S.2
Lawson, G.3
Collard, E.4
-
81
-
-
0029907755
-
Arytenoid cartilage dislocation caused by a laryngeal mask airway treated with chemical splinting
-
M. K. Rosenberg, E. Rontal, M. Rontal, and M. Lebenbom-Mansour, "Arytenoid cartilage dislocation caused by a laryngeal mask airway treated with chemical splinting, " Anesthesia and Analgesia, vol. 83, no. 6, pp. 1335-1336, 1996.
-
(1996)
Anesthesia and Analgesia
, vol.83
, Issue.6
, pp. 1335-1336
-
-
Rosenberg, M.K.1
Rontal, E.2
Rontal, M.3
Lebenbom-Mansour, M.4
-
82
-
-
0024839069
-
Laryngealmask and trauma to uvula
-
J. J. Lee, "Laryngealmask and trauma to uvula, " Anaesthesia, vol. 44, no. 12, p. 1014, 1989.
-
(1989)
Anaesthesia
, vol.44
, Issue.12
, pp. 1014
-
-
Lee, J.J.1
-
83
-
-
84865246713
-
Uvular trauma from a laryngeal mask
-
S. R. Emmett, S. D. Lloyd, and M. N. Johnston, "Uvular trauma from a laryngeal mask, " British Journal of Anaesthesia, vol. 109, no. 3, pp. 468-469, 2012.
-
(2012)
British Journal of Anaesthesia
, vol.109
, Issue.3
, pp. 468-469
-
-
Emmett, S.R.1
Lloyd, S.D.2
Johnston, M.N.3
-
84
-
-
0029125136
-
Epiglottitis after anaesthesia with a laryngealmask
-
B. McKinney and R. Grigg, "Epiglottitis after anaesthesia with a laryngealmask, " Anaesthesia and Intensive Care, vol. 23, no. 5, pp. 618-619, 1995.
-
(1995)
Anaesthesia and Intensive Care
, vol.23
, Issue.5
, pp. 618-619
-
-
McKinney, B.1
Grigg, R.2
-
85
-
-
84925301728
-
Severe hoarseness associated with the streamlined liner of the pharyngeal airway (SLIPATM)
-
X.-X. Ma and X.-M. Fang, "Severe hoarseness associated with the streamlined liner of the pharyngeal airway (SLIPATM), " Acta Anaesthesiologica Scandinavica, vol. 59, no. 4, pp. 531-535, 2015.
-
(2015)
Acta Anaesthesiologica Scandinavica
, vol.59
, Issue.4
, pp. 531-535
-
-
Ma, X.-X.1
Fang, X.-M.2
-
86
-
-
0032929862
-
An unexpected complication of the intubating laryngeal mask
-
M. A. Branthwaite, "An unexpected complication of the intubating laryngeal mask, " Anaesthesia, vol. 54, no. 2, pp. 166-167, 1999.
-
(1999)
Anaesthesia
, vol.54
, Issue.2
, pp. 166-167
-
-
Branthwaite, M.A.1
-
87
-
-
63849325375
-
Deep neck abscess and mediastinitis after laryngeal mask anesthesia
-
M. Paciuc, "Deep neck abscess and mediastinitis after laryngeal mask anesthesia, " Anesthesia and Analgesia, vol. 108, no. 4, pp. 1356-1357, 2009.
-
(2009)
Anesthesia and Analgesia
, vol.108
, Issue.4
, pp. 1356-1357
-
-
Paciuc, M.1
-
88
-
-
67649149087
-
Anteriormediastinitis following traumatic laryngeal mask placement
-
C. Yegappan, E. Redmond, and K. LeDez, "Anteriormediastinitis following traumatic laryngeal mask placement, " Canadian Journal of Anaesthesia, vol. 54, supplement 1, p. 44568, 2007.
-
(2007)
Canadian Journal of Anaesthesia
, vol.54
, pp. 44568
-
-
Yegappan, C.1
Redmond, E.2
LeDez, K.3
-
89
-
-
84954180683
-
A complication of the laryngeal mask airway: Pharyngolaryngeal rupture and pneumomediastinum
-
Y. O. Atalay, C. Kaya, S. Aktas, and K. Toker, "A complication of the laryngeal mask airway: pharyngolaryngeal rupture and pneumomediastinum, " European Journal of Anaesthesiology, vol. 32, no. 6, pp. 439-440, 2015.
-
(2015)
European Journal of Anaesthesiology
, vol.32
, Issue.6
, pp. 439-440
-
-
Atalay, Y.O.1
Kaya, C.2
Aktas, S.3
Toker, K.4
-
90
-
-
84954146316
-
Mucosal erosion of the cricoid cartilage after the use of an i-gel supraglottic airway device in a patient with diffuse idiopathic skeletal hyperostosis
-
A. C. Schaer, M. J. Keel, P. Dubach, R. Greif, C. Luyet, and L. Theiler, "Mucosal erosion of the cricoid cartilage after the use of an i-gel supraglottic airway device in a patient with diffuse idiopathic skeletal hyperostosis, "A&ACase Reports, vol. 3, no. 4, pp. 45-47, 2014.
-
(2014)
A&A Case Reports
, vol.3
, Issue.4
, pp. 45-47
-
-
Schaer, A.C.1
Keel, M.J.2
Dubach, P.3
Greif, R.4
Luyet, C.5
Theiler, L.6
-
91
-
-
0031962184
-
Bilateral lingual nerve injury following the use of the laryngealmask airway
-
S. Majumder and P. M. Hopkins, "Bilateral lingual nerve injury following the use of the laryngealmask airway, "Anaesthesia, vol. 53, no. 2, pp. 184-186, 1998.
-
(1998)
Anaesthesia
, vol.53
, Issue.2
, pp. 184-186
-
-
Majumder, S.1
Hopkins, P.M.2
-
92
-
-
77954424233
-
Transient isolated lingual nerve neuropraxia associated with general anaesthesia and laryngeal mask use: Two case reports and a review of the literature
-
E. Foley, T. E. D. Mc Dermott, E. Shanahan, and D. Phelan, "Transient isolated lingual nerve neuropraxia associated with general anaesthesia and laryngeal mask use: two case reports and a review of the literature, " Irish Journal ofMedical Science, vol. 179, no. 2, pp. 297-300, 2010.
-
(2010)
Irish Journal of Medical Science
, vol.179
, Issue.2
, pp. 297-300
-
-
Foley, E.1
Mc Dermott, T.E.D.2
Shanahan, E.3
Phelan, D.4
-
93
-
-
84866052717
-
Bilateral lingual nerve injury associated with classic laryngeal mask airway: A case report
-
M. El Toukhy and O. Tweedie, "Bilateral lingual nerve injury associated with classic laryngeal mask airway: a case report, " European Journal of Anaesthesiology, vol. 29, no. 8, pp. 400-401, 2012.
-
(2012)
European Journal of Anaesthesiology
, vol.29
, Issue.8
, pp. 400-401
-
-
El Toukhy, M.1
Tweedie, O.2
-
94
-
-
24944482175
-
Lingual nerve injury associated with the ProSeal laryngealmask airway: A case report and review of the literature
-
J. Brimacombe, G. Clarke, and C. Keller, "Lingual nerve injury associated with the ProSeal laryngealmask airway: a case report and review of the literature, " British Journal of Anaesthesia, vol. 95, no. 3, pp. 420-423, 2005.
-
(2005)
British Journal of Anaesthesia
, vol.95
, Issue.3
, pp. 420-423
-
-
Brimacombe, J.1
Clarke, G.2
Keller, C.3
-
95
-
-
84866274201
-
Tongue numbness following laryngeal mask airway Supreme and i-gel insertion: Two case reports
-
P. Rujirojindakul, C. Prechawai, and E. Watanayomnaporn, "Tongue numbness following laryngeal mask airway Supreme and i-gel insertion: two case reports, " Acta Anaesthesiologica Scandinavica, vol. 56, no. 9, pp. 1200-1203, 2012.
-
(2012)
Acta Anaesthesiologica Scandinavica
, vol.56
, Issue.9
, pp. 1200-1203
-
-
Rujirojindakul, P.1
Prechawai, C.2
Watanayomnaporn, E.3
-
96
-
-
84897723495
-
Lingual nerve neuropraxia following use of the Laryngeal Mask Airway Supreme
-
V. Thiruvenkatarajan, R. M. A. W. Van Wijk, I. Elhalawani, and A.-M. Barnes, "Lingual nerve neuropraxia following use of the Laryngeal Mask Airway Supreme, " Journal of Clinical Anesthesia, vol. 26, no. 1, pp. 65-68, 2014.
-
(2014)
Journal of Clinical Anesthesia
, vol.26
, Issue.1
, pp. 65-68
-
-
Thiruvenkatarajan, V.1
Van Wijk, R.M.A.W.2
Elhalawani, I.3
Barnes, A.-M.4
-
97
-
-
79951748337
-
Lingual nerve injury following the use of an i-gel laryngealmask
-
S. H. Renes, R. Zwart, G. J. Scheffer, and S. Renes, "Lingual nerve injury following the use of an i-gel laryngealmask, " Anaesthesia, vol. 66, no. 3, pp. 226-227, 2011.
-
(2011)
Anaesthesia
, vol.66
, Issue.3
, pp. 226-227
-
-
Renes, S.H.1
Zwart, R.2
Scheffer, G.J.3
Renes, S.4
-
98
-
-
0028284660
-
Unilateral hypoglossal nerve paralysis following the use of the laryngeal mask airway
-
K. Nagai, C. Sakuramoto, and F. Goto, "Unilateral hypoglossal nerve paralysis following the use of the laryngeal mask airway, " Anaesthesia, vol. 49, no. 7, pp. 603-604, 1994.
-
(1994)
Anaesthesia
, vol.49
, Issue.7
, pp. 603-604
-
-
Nagai, K.1
Sakuramoto, C.2
Goto, F.3
-
99
-
-
0036192259
-
Bilateral hypoglossal nerve injury following the use of the laryngeal mask airway
-
A. Stewart and W. A. Lindsay, "Bilateral hypoglossal nerve injury following the use of the laryngeal mask airway, " Anaesthesia, vol. 57, no. 3, pp. 264-265, 2002.
-
(2002)
Anaesthesia
, vol.57
, Issue.3
, pp. 264-265
-
-
Stewart, A.1
Lindsay, W.A.2
-
100
-
-
11444257729
-
Unilateral hypoglossal nerve injury following the use of a ProSeal laryngeal mask
-
P. Trümpelmann and T. Cook, "Unilateral hypoglossal nerve injury following the use of a ProSeal laryngeal mask, " Anaesthesia, vol. 60, no. 1, pp. 101-102, 2005.
-
(2005)
Anaesthesia
, vol.60
, Issue.1
, pp. 101-102
-
-
Trümpelmann, P.1
Cook, T.2
-
101
-
-
84954139659
-
Unilateral hypoglossal nerve palsy after use of the laryngeal mask airway Supreme
-
Article ID 369563
-
K. Takahoko, H. Iwasaki, T. Sasakawa, A. Suzuki, H. Matsumoto, and H. Iwasaki, "Unilateral hypoglossal nerve palsy after use of the laryngeal mask airway Supreme, " Case Reports in Anesthesiology, vol. 2014, Article ID 369563, 4 pages, 2014.
-
(2014)
Case Reports in Anesthesiology
, vol.2014
, pp. 4
-
-
Takahoko, K.1
Iwasaki, H.2
Sasakawa, T.3
Suzuki, A.4
Matsumoto, H.5
Iwasaki, H.6
-
102
-
-
0028930622
-
Transient bilateral vocal cord paralysis after insertion of a laryngeal mask airway
-
S. Inomata, T. Nishikawa, A. Suga, and S. Yamashita, "Transient bilateral vocal cord paralysis after insertion of a laryngeal mask airway, " Anesthesiology, vol. 82, no. 3, pp. 787-788, 1995.
-
(1995)
Anesthesiology
, vol.82
, Issue.3
, pp. 787-788
-
-
Inomata, S.1
Nishikawa, T.2
Suga, A.3
Yamashita, S.4
-
103
-
-
0030077068
-
Recurrent laryngeal nervepalsy after laryngeal mask airway insertion
-
F. R. LloydJones and A. Hegab, "Recurrent laryngeal nervepalsy after laryngeal mask airway insertion, " Anaesthesia, vol. 51, no. 2, pp. 171-172, 1996.
-
(1996)
Anaesthesia
, vol.51
, Issue.2
, pp. 171-172
-
-
LloydJones, F.R.1
Hegab, A.2
-
104
-
-
0029942534
-
Vocal fold palsy after use of the laryngealmask airway
-
H. Daya, W. J. Fawcett, and N. Weir, "Vocal fold palsy after use of the laryngealmask airway, " Journal of Laryngology and Otology, vol. 110, no. 4, pp. 383-384, 1996.
-
(1996)
Journal of Laryngology and Otology
, vol.110
, Issue.4
, pp. 383-384
-
-
Daya, H.1
Fawcett, W.J.2
Weir, N.3
-
105
-
-
0031044258
-
Severe dysphonia after use of a laryngealmask airway
-
A. M. Cros, R. Pitti, C. Conil, D. Giraud, and J. Verhulst, "Severe dysphonia after use of a laryngealmask airway, " Anesthesiology, vol. 86, no. 2, pp. 498-500, 1997.
-
(1997)
Anesthesiology
, vol.86
, Issue.2
, pp. 498-500
-
-
Cros, A.M.1
Pitti, R.2
Conil, C.3
Giraud, D.4
Verhulst, J.5
-
106
-
-
0033943373
-
Bilateral recurrent laryngeal nerve neuropraxia following laryngeal mask insertion: A rare cause of serious upper airway morbidity
-
M. D. Sacks and D. Marsh, "Bilateral recurrent laryngeal nerve neuropraxia following laryngeal mask insertion: a rare cause of serious upper airway morbidity, " Pediatric Anesthesia, vol. 10, no. 4, pp. 435-437, 2000.
-
(2000)
Pediatric Anesthesia
, vol.10
, Issue.4
, pp. 435-437
-
-
Sacks, M.D.1
Marsh, D.2
-
107
-
-
40549143462
-
Nerve damage following the use of an i-gel supraglottic airway device
-
A. D. Theron and C. Loyden, "Nerve damage following the use of an i-gel supraglottic airway device, " Anaesthesia, vol. 63, no. 4, p. 441, 2008.
-
(2008)
Anaesthesia
, vol.63
, Issue.4
, pp. 441
-
-
Theron, A.D.1
Loyden, C.2
-
108
-
-
40549143462
-
Nerve damage following the use of an i-gel supraglottic airway device
-
A. D. Theron and C. Loyden, "Nerve damage following the use of an i-gel supraglottic airway device, " Anaesthesia, vol. 63, no. 4, p. 441, 2008.
-
(2008)
Anaesthesia
, vol.63
, Issue.4
, pp. 441
-
-
Theron, A.D.1
Loyden, C.2
-
109
-
-
0032944649
-
Postoperative sore throat: Cause, prevention and treatment
-
F. E. McHardy and F. Chung, "Postoperative sore throat: cause, prevention and treatment, " Anaesthesia, vol. 54, no. 5, pp. 444-453, 1999.
-
(1999)
Anaesthesia
, vol.54
, Issue.5
, pp. 444-453
-
-
McHardy, F.E.1
Chung, F.2
-
110
-
-
77957718840
-
Postoperative sore throat: More answers than questions
-
P. E. Scuderi, "Postoperative sore throat: more answers than questions, " Anesthesia and Analgesia, vol. 111, no. 4, pp. 831-832, 2010.
-
(2010)
Anesthesia and Analgesia
, vol.111
, Issue.4
, pp. 831-832
-
-
Scuderi, P.E.1
-
111
-
-
0036168412
-
Tracheal intubation and sore throat: A mechanical explanation
-
M. Chandler, "Tracheal intubation and sore throat: a mechanical explanation, " Anaesthesia, vol. 57, no. 2, pp. 155-161, 2002.
-
(2002)
Anaesthesia
, vol.57
, Issue.2
, pp. 155-161
-
-
Chandler, M.1
-
112
-
-
70349572485
-
Acomparison of postoperative throat and neck complaints after the use of the i-gel and the la Premiere disposable laryngeal mask: A doubleblinded randomized controlled trial
-
C. Keijzer, D. R. Buitelaar, K. M. Efthymiou, et al., "Acomparison of postoperative throat and neck complaints after the use of the i-gel and the La Premiere disposable laryngeal mask: a doubleblinded, randomized, controlled trial, " Anesthesia & Analgesia, vol. 109, no. 4, pp. 1092-1095, 2009.
-
(2009)
Anesthesia & Analgesia
, vol.109
, Issue.4
, pp. 1092-1095
-
-
Keijzer, C.1
Buitelaar, D.R.2
Efthymiou, K.M.3
-
113
-
-
0034929328
-
Routine use of the intubating laryngeal mask air-way results in increased upper airway morbidity
-
S. Kihara, Y. Yaguchi, J. Brimacombe, S. Watanabe, and N. Taguchi, "Routine use of the intubating laryngeal mask air-way results in increased upper airway morbidity, " Canadian Journal of Anesthesia, vol. 48, no. 6, pp. 604-608, 2001.
-
(2001)
Canadian Journal of Anesthesia
, vol.48
, Issue.6
, pp. 604-608
-
-
Kihara, S.1
Yaguchi, Y.2
Brimacombe, J.3
Watanabe, S.4
Taguchi, N.5
-
114
-
-
84863208202
-
The effect of cuff pressure on postoperative sore throat after Cobra perilaryngeal airway
-
H. B. Joe, J. Y. Kim, D. H. Kim, M. Kang, Y. J. Chae, and K. S. Park, "The effect of cuff pressure on postoperative sore throat after Cobra perilaryngeal airway, " Journal of Anesthesia, vol. 26, no. 2, pp. 225-229, 2012.
-
(2012)
Journal of Anesthesia
, vol.26
, Issue.2
, pp. 225-229
-
-
Joe, H.B.1
Kim, J.Y.2
Kim, D.H.3
Kang, M.4
Chae, Y.J.5
Park, K.S.6
-
115
-
-
16844377320
-
The ProSeal laryngeal mask airway and the Laryngeal Tube Suction for ventilation in gynaecological patients undergoing laparoscopic surgery
-
H. Roth, H. V. Genzwuerker, A. Rothhaas, T. Finteis, and J. Schmeck, "The ProSeal laryngeal mask airway and the Laryngeal Tube Suction for ventilation in gynaecological patients undergoing laparoscopic surgery, " European Journal of Anaesthesiology, vol. 22, no. 2, pp. 117-122, 2005.
-
(2005)
European Journal of Anaesthesiology
, vol.22
, Issue.2
, pp. 117-122
-
-
Roth, H.1
Genzwuerker, H.V.2
Rothhaas, A.3
Finteis, T.4
Schmeck, J.5
-
116
-
-
0042329318
-
Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation
-
T. M. Cook, B. McCormick, and T. Asai, "Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation, " British Journal of Anaesthesia, vol. 91, no. 3, pp. 373-378, 2003.
-
(2003)
British Journal of Anaesthesia
, vol.91
, Issue.3
, pp. 373-378
-
-
Cook, T.M.1
McCormick, B.2
Asai, T.3
-
117
-
-
84864741230
-
Randomized comparison of the i-gel, the LMA Supreme, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients
-
article 18
-
S. G. Russo, S. Cremer, T. Galli, et al., "Randomized comparison of the i-gel, the LMA Supreme, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients, " BMC Anesthesiology, vol. 12, article 18, 2012.
-
(2012)
BMC Anesthesiology
, vol.12
-
-
Russo, S.G.1
Cremer, S.2
Galli, T.3
-
118
-
-
0031447104
-
Haemodynamic changes with the laryngeal mask airway-off the cuff
-
S. Colbert, D. M. O'Hanlon, R. Page, F. Flanagan, and D. Moriarty, "Haemodynamic changes with the laryngeal mask airway-off the cuff, " European Journal of Anaesthesiology, vol. 14, no. 5, pp. 514-517, 1997.
-
(1997)
European Journal of Anaesthesiology
, vol.14
, Issue.5
, pp. 514-517
-
-
Colbert, S.1
O'Hanlon, D.M.2
Page, R.3
Flanagan, F.4
Moriarty, D.5
-
119
-
-
0031919704
-
The laryngealmask airway reduces blood flow in the common carotid artery bulb
-
S.-A. Colbert, D. M. O'Hanlon, F. Flanagan, R. Page, and D. C. Moriarty, "The laryngealmask airway reduces blood flow in the common carotid artery bulb, " Canadian Journal of Anaesthesia, vol. 45, no. 1, pp. 23-27, 1998.
-
(1998)
Canadian Journal of Anaesthesia
, vol.45
, Issue.1
, pp. 23-27
-
-
Colbert, S.-A.1
O'Hanlon, D.M.2
Flanagan, F.3
Page, R.4
Moriarty, D.C.5
-
120
-
-
84863819480
-
Impairment of carotid artery blood flow by supraglottic airway use in a swine model of cardiac arrest
-
N. Segal, D. Yannopoulos, B. D. Mahoney, et al., "Impairment of carotid artery blood flow by supraglottic airway use in a swine model of cardiac arrest, " Resuscitation, vol. 83, no. 8, pp. 1025-1030, 2012.
-
(2012)
Resuscitation
, vol.83
, Issue.8
, pp. 1025-1030
-
-
Segal, N.1
Yannopoulos, D.2
Mahoney, B.D.3
-
121
-
-
0031030950
-
The effect of laryngeal mask airway insertion on the position of the internal jugular vein
-
N. Nandwani, M. C. Fairfield, K. Krarup, and J. Thompson, "The effect of laryngeal mask airway insertion on the position of the internal jugular vein, " Anaesthesia, vol. 52, no. 1, pp. 77-79, 1997.
-
(1997)
Anaesthesia
, vol.52
, Issue.1
, pp. 77-79
-
-
Nandwani, N.1
Fairfield, M.C.2
Krarup, K.3
Thompson, J.4
-
122
-
-
78650402426
-
The anatomic relationship between the internal jugular vein and the carotid artery in children after laryngeal mask insertion. An ultrasonographic study
-
R. G. Nagaraja, M. Wilson, G. Wilson, B. Marciniak, and T. Engelhardt, "The anatomic relationship between the internal jugular vein and the carotid artery in children after laryngeal mask insertion. An ultrasonographic study, " Paediatric Anaesthesia, vol. 21, no. 1, pp. 62-64, 2011.
-
(2011)
Paediatric Anaesthesia
, vol.21
, Issue.1
, pp. 62-64
-
-
Nagaraja, R.G.1
Wilson, M.2
Wilson, G.3
Marciniak, B.4
Engelhardt, T.5
-
123
-
-
4444378186
-
Venous congestion of the neck; Its relation to laryngeal mask cuff pressures
-
R. J. Lenoir, "Venous congestion of the neck; its relation to laryngeal mask cuff pressures, " British Journal of Anaesthesia, vol. 93, no. 3, pp. 476-477, 2004.
-
(2004)
British Journal of Anaesthesia
, vol.93
, Issue.3
, pp. 476-477
-
-
Lenoir, R.J.1
-
124
-
-
0017357049
-
The trachea and cuff-induced tracheal injury. An experimental study on causative factors and prevention
-
U. Nordin, "The trachea and cuff-induced tracheal injury. An experimental study on causative factors and prevention, " Acta Oto-Laryngologica, vol. 345, supplement 1, pp. 1-71, 1976.
-
(1976)
Acta Oto-Laryngologica
, vol.345
, pp. 1-71
-
-
Nordin, U.1
-
125
-
-
0022342261
-
True vocal cord paralysis following intubation
-
J. W. Cavo Jr., "True vocal cord paralysis following intubation, " Laryngoscope, vol. 95, no. 11, pp. 1352-1359, 1985.
-
(1985)
Laryngoscope
, vol.95
, Issue.11
, pp. 1352-1359
-
-
Cavo, J.W.1
-
126
-
-
0027530403
-
Pressure exerted by the laryngeal mask airway cuff upon the pharyngeal mucosa
-
R. Marjot, "Pressure exerted by the laryngeal mask airway cuff upon the pharyngeal mucosa, " British Journal of Anaesthesia, vol. 70, no. 1, pp. 25-29, 1993.
-
(1993)
British Journal of Anaesthesia
, vol.70
, Issue.1
, pp. 25-29
-
-
Marjot, R.1
-
127
-
-
0027752438
-
Astudy of laryngeal mask inflation. Pressures exerted on the pharynx
-
S. W. O'Kelly, K. J. Heath, and E. G. Lawes, "Astudy of laryngeal mask inflation. Pressures exerted on the pharynx, " Anaesthesia, vol. 48, no. 12, pp. 1075-1078, 1993.
-
(1993)
Anaesthesia
, vol.48
, Issue.12
, pp. 1075-1078
-
-
O'Kelly, S.W.1
Heath, K.J.2
Lawes, E.G.3
-
128
-
-
0033029578
-
Calculated vs measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: Assessment of four locations
-
C. Keller, J. Brimacombe, and A. Benzer, "Calculated vs measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: assessment of four locations, " British Journal of Anaesthesia, vol. 82, no. 3, pp. 399-401, 1999.
-
(1999)
British Journal of Anaesthesia
, vol.82
, Issue.3
, pp. 399-401
-
-
Keller, C.1
Brimacombe, J.2
Benzer, A.3
-
129
-
-
0036234840
-
The influence of cuff volume and anatomic location on pharyngeal, esophageal, and trachealmucosal pressures with the esophageal tracheal combitube
-
C. Keller, J. Brimacombe, M. Boehler, A. Loeckinger, and F. Puehringer, "The influence of cuff volume and anatomic location on pharyngeal, esophageal, and trachealmucosal pressures with the esophageal tracheal combitube, " Anesthesiology, vol. 96, no. 5, pp. 1074-1077, 2002.
-
(2002)
Anesthesiology
, vol.96
, Issue.5
, pp. 1074-1077
-
-
Keller, C.1
Brimacombe, J.2
Boehler, M.3
Loeckinger, A.4
Puehringer, F.5
-
130
-
-
0037000283
-
Large cuff volumes impede posterior pharyngeal mucosal perfusion with the laryngeal tube airway
-
J. Brimacombe, C. Keller, W. Roth, and A. Loeckinger, "Large cuff volumes impede posterior pharyngeal mucosal perfusion with the laryngeal tube airway, " Canadian Journal of Anesthesia, vol. 49, no. 10, pp. 1084-1087, 2002.
-
(2002)
Canadian Journal of Anesthesia
, vol.49
, Issue.10
, pp. 1084-1087
-
-
Brimacombe, J.1
Keller, C.2
Roth, W.3
Loeckinger, A.4
-
131
-
-
35349005897
-
Laryngopharyngeal mucosal injury after prolonged use of the ProSeal LMA in a porcine model: A pilot study
-
K. Goldmann, J. Dieterich, and M. Roessler, "Laryngopharyngeal mucosal injury after prolonged use of the ProSeal LMA in a porcine model: a pilot study, " Canadian Journal of Anesthesia, vol. 54, no. 10, pp. 822-828, 2007.
-
(2007)
Canadian Journal of Anesthesia
, vol.54
, Issue.10
, pp. 822-828
-
-
Goldmann, K.1
Dieterich, J.2
Roessler, M.3
-
132
-
-
0034766481
-
High laryngeal mask airway pressures resulting from nitrous oxide do not increase pharyngeal mucosal injury in dogs
-
T. M. V. Abud, J. R. C. Braz, R. H. G. Martins, E. A. Gregório, and J. C. Saldanha, "High laryngeal mask airway pressures resulting from nitrous oxide do not increase pharyngeal mucosal injury in dogs, " Canadian Journal of Anesthesia, vol. 48, no. 8, pp. 800-806, 2001.
-
(2001)
Canadian Journal of Anesthesia
, vol.48
, Issue.8
, pp. 800-806
-
-
Abud, T.M.V.1
Braz, J.R.C.2
Martins, R.H.G.3
Gregório, E.A.4
Saldanha, J.C.5
-
133
-
-
0034120342
-
Effect of high laryngeal mask airway intracuff pressure on the laryngopharyngeal mucosa of dogs
-
R. H. G. Martins, J. R. C. Braz, J. Defaveri, E. A. Gregörio, and T. M. V. Abud, "Effect of high laryngeal mask airway intracuff pressure on the laryngopharyngeal mucosa of dogs, " Laryngoscope, vol. 110, no. 4, pp. 645-650, 2000.
-
(2000)
Laryngoscope
, vol.110
, Issue.4
, pp. 645-650
-
-
Martins, R.H.G.1
Braz, J.R.C.2
Defaveri, J.3
Gregörio, E.A.4
Abud, T.M.V.5
-
134
-
-
0032826302
-
Influence of neuromuscular block, mode of ventilation and respiratory cycle on pharyngeal mucosal pressures with the laryngeal mask airway
-
C. Keller and J. Brimacombe, "Influence of neuromuscular block, mode of ventilation and respiratory cycle on pharyngeal mucosal pressures with the laryngeal mask airway, " British Journal of Anaesthesia, vol. 83, no. 3, pp. 480-482, 1999.
-
(1999)
British Journal of Anaesthesia
, vol.83
, Issue.3
, pp. 480-482
-
-
Keller, C.1
Brimacombe, J.2
-
135
-
-
33646767076
-
Comparison of mucosal pressures induced by cuffs of different airway devices
-
H. Ulrich-Pur, F. Hrska, P. Krafft, et al., "Comparison of mucosal pressures induced by cuffs of different airway devices, " Anesthesiology, vol. 104, no. 5, pp. 933-938, 2006.
-
(2006)
Anesthesiology
, vol.104
, Issue.5
, pp. 933-938
-
-
Ulrich-Pur, H.1
Hrska, F.2
Krafft, P.3
-
136
-
-
79955817731
-
Endotracheal tube and laryngeal mask airway cuff pressures can exceed critical values during ascent to higher altitude
-
R. M. Miyashiro and L. G. Yamamoto, "Endotracheal tube and laryngeal mask airway cuff pressures can exceed critical values during ascent to higher altitude, " Pediatric Emergency Care, vol. 27, no. 5, pp. 367-370, 2011.
-
(2011)
Pediatric Emergency Care
, vol.27
, Issue.5
, pp. 367-370
-
-
Miyashiro, R.M.1
Yamamoto, L.G.2
-
137
-
-
34147177575
-
Endotracheal tube and laryngeal mask airway cuff volume changes with altitude: A rule of thumb for aeromedical transport
-
C. Mann, N. Parkinson, and A. Bleetman, "Endotracheal tube and laryngeal mask airway cuff volume changes with altitude: a rule of thumb for aeromedical transport, " Emergency Medicine Journal, vol. 24, no. 3, pp. 165-167, 2007.
-
(2007)
Emergency Medicine Journal
, vol.24
, Issue.3
, pp. 165-167
-
-
Mann, C.1
Parkinson, N.2
Bleetman, A.3
-
138
-
-
79955516461
-
Characterization of airway device cuff volumes at simulated altitude
-
J. Law, A. Bair, J. Capra, A. Holder, and R. Allen, "Characterization of airway device cuff volumes at simulated altitude, " Aviation, Space and Environmental Medicine, vol. 82, no. 5, pp. 555-558, 2011.
-
(2011)
Aviation, Space and Environmental Medicine
, vol.82
, Issue.5
, pp. 555-558
-
-
Law, J.1
Bair, A.2
Capra, J.3
Holder, A.4
Allen, R.5
|