메뉴 건너뛰기




Volumn 21, Issue 1, 2011, Pages 62-64

The anatomic relationship between the internal jugular vein and the carotid artery in children after laryngeal mask insertion. An ultrasonographic study

Author keywords

internal jugular vein; laryngeal mask airway; ultrasound

Indexed keywords

ADOLESCENT; AGE; ANATOMICAL VARIATION; ARTICLE; BODY WEIGHT; BREATHING PATTERN; CAROTID ARTERY; CHILD; CRICOID; ECHOGRAPHY; HEAD POSITION; HUMAN; INHALATION; INTERNAL JUGULAR VEIN; LARYNGEAL MASK; MAJOR CLINICAL STUDY; PRESCHOOL CHILD; PRIORITY JOURNAL; PROSPECTIVE STUDY; SCHOOL CHILD; VEIN CATHETERIZATION;

EID: 78650402426     PISSN: 11555645     EISSN: 14609592     Source Type: Journal    
DOI: 10.1111/j.1460-9592.2010.03459.x     Document Type: Article
Times cited : (10)

References (15)
  • 1
    • 0026555361 scopus 로고
    • Internal jugular vein catheterization in infants undergoing cardiovascular surgery; An analysis of the factors influencing successful catheterization
    • Hayashi Y, Uchida O, Takaki O, et al. Internal jugular vein catheterization in infants undergoing cardiovascular surgery; An analysis of the factors influencing successful catheterization. Anesth Analg 1992; 74: 688-693.
    • (1992) Anesth Analg , vol.74 , pp. 688-693
    • Hayashi, Y.1    Uchida, O.2    Takaki, O.3
  • 2
    • 0030797995 scopus 로고    scopus 로고
    • Airway obstruction following internal jugular vein cannulation
    • Kua JS, Tan IK,. Airway obstruction following internal jugular vein cannulation. Anesthesia 1997; 52: 776-780.
    • (1997) Anesthesia , vol.52 , pp. 776-780
    • Kua, J.S.1    Tan, I.K.2
  • 3
    • 0032983589 scopus 로고    scopus 로고
    • Ultrasound-guided internal jugular venous cannulation in infants
    • Verghese ST, McGill WA, Patel RI, et al. Ultrasound-guided internal jugular venous cannulation in infants. Anesthesiology 1999; 91: 71-77.
    • (1999) Anesthesiology , vol.91 , pp. 71-77
    • Verghese, S.T.1    McGill, W.A.2    Patel, R.I.3
  • 4
    • 0043234290 scopus 로고    scopus 로고
    • Ultrasonic locating devices for central venous cannulation: Meta-analysis
    • Hind D, Calvert N, McWilliams R, et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 2003; 327: 361.
    • (2003) BMJ , vol.327 , pp. 361
    • Hind, D.1    Calvert, N.2    McWilliams, R.3
  • 5
    • 0030774628 scopus 로고    scopus 로고
    • Improvement of internal jugular vein cannulation using an ultrasound-guided technique
    • Slama M, Novara A, Safavian A, et al. Improvement of internal jugular vein cannulation using an ultrasound-guided technique. Intensiv Care Med 1997; 23: 916-919.
    • (1997) Intensiv Care Med , vol.23 , pp. 916-919
    • Slama, M.1    Novara, A.2    Safavian, A.3
  • 6
    • 0033824285 scopus 로고    scopus 로고
    • Comparison of three techniques for internal jugular vein cannulation in infants
    • Verghese ST, McGill WA, Patel RI, et al. Comparison of three techniques for internal jugular vein cannulation in infants. Pediatr Anesth 2000; 10: 505-511.
    • (2000) Pediatr Anesth , vol.10 , pp. 505-511
    • Verghese, S.T.1    McGill, W.A.2    Patel, R.I.3
  • 7
    • 0026337972 scopus 로고
    • Anatomical variation of the internal jugular vein location: Impact on central venous access
    • Denys BG, Uretsky BF,. Anatomical variation of the internal jugular vein location: impact on central venous access. Crit Care Med 1991; 19: 1516-1519.
    • (1991) Crit Care Med , vol.19 , pp. 1516-1519
    • Denys, B.G.1    Uretsky, B.F.2
  • 8
    • 0030057294 scopus 로고    scopus 로고
    • Internal jugular vein and carotid artery anatomic Relation as determined by ultrasonography
    • Troianos CA, Kuwik RJ, Pasqual JR, et al. Internal jugular vein and carotid artery anatomic Relation as determined by ultrasonography. Anesthesiology 1996; 85: 43-48.
    • (1996) Anesthesiology , vol.85 , pp. 43-48
    • Troianos, C.A.1    Kuwik, R.J.2    Pasqual, J.R.3
  • 9
    • 19944430853 scopus 로고    scopus 로고
    • Circumferential adjustment of ultrasound probe position to determine the optimal approach to the internal jugular vein: A non-invasive geometric study in adults
    • Riopelle JM, Ruiz DP, Hunt JP, et al. Circumferential adjustment of ultrasound probe position to determine the optimal approach to the internal jugular vein: a non-invasive geometric study in adults. Anesth Analg 2005; 100: 512-519.
    • (2005) Anesth Analg , vol.100 , pp. 512-519
    • Riopelle, J.M.1    Ruiz, D.P.2    Hunt, J.P.3
  • 10
    • 47349113693 scopus 로고    scopus 로고
    • Anatomic relationship between the internal jugular vein and the carotid artery in pre-school children - An ultrasonographic study
    • Roth B, Marciniak B, Engelhardt T, et al. Anatomic relationship between the internal jugular vein and the carotid artery in pre-school children-an ultrasonographic study. Pediatr Anesth 2008; 18: 752-756.
    • (2008) Pediatr Anesth , vol.18 , pp. 752-756
    • Roth, B.1    Marciniak, B.2    Engelhardt, T.3
  • 11
    • 0017286371 scopus 로고
    • Percutaneous catheterisation of the internal jugular vein in infants and children
    • Prince SR, Sullivan RL, Hackel A, Percutaneous catheterisation of the internal jugular vein in infants and children. Anesthesiology 1976; 44: 170-174.
    • (1976) Anesthesiology , vol.44 , pp. 170-174
    • Prince, S.R.1    Sullivan, R.L.2    Hackel, A.3
  • 12
    • 0025110919 scopus 로고
    • The laryngeal mask airway in children
    • Mason DG, Bingham RM,. The laryngeal mask airway in children. Anaesthesia 1990; 45: 760-763.
    • (1990) Anaesthesia , vol.45 , pp. 760-763
    • Mason, D.G.1    Bingham, R.M.2
  • 13
    • 0029851782 scopus 로고    scopus 로고
    • Safety and efficacy of the laryngeal mask airway: A prospective survey of 1400 children
    • Lopez-Gil M, Brimacombe J, Alvarez M,. Safety and efficacy of the laryngeal mask airway: a prospective survey of 1400 children. Anaesthesia 1996; 51: 969-972.
    • (1996) Anaesthesia , vol.51 , pp. 969-972
    • Lopez-Gil, M.1    Brimacombe, J.2    Alvarez, M.3
  • 14
    • 0033985165 scopus 로고    scopus 로고
    • The laryngeal mask airway in the difficult paediatric airway: An assessment of positioning and use in fibreoptic intubation
    • Walker RWM,. The laryngeal mask airway in the difficult paediatric airway: an assessment of positioning and use in fibreoptic intubation. Pediatr Anesth 2000; 10: 53-58.
    • (2000) Pediatr Anesth , vol.10 , pp. 53-58
    • Walker, R.W.M.1
  • 15
    • 48649099566 scopus 로고    scopus 로고
    • (accessed 18 August 2010)
    • Difficult airway society guidelines. http://www.das.uk.com/guidelines/ guidelineshome.html (accessed 18 August 2010).
    • Difficult Airway Society Guidelines


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.