메뉴 건너뛰기




Volumn 91, Issue 3, 2003, Pages 373-378

Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation

Author keywords

Equipment, masks laryngeal; Equipment, tubes laryngeal

Indexed keywords

ADULT; AGED; AIRWAY PRESSURE; ARTICLE; ARTIFICIAL VENTILATION; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DISEASE SEVERITY; DYSPHAGIA; DYSPHONIA; FEMALE; HUMAN; INCIDENCE; INTUBATION; LARYNGEAL MASK; MAJOR CLINICAL STUDY; MALE; NECK PAIN; OTALGIA; POSTOPERATIVE COMPLICATION; PRESSURE MEASUREMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; SORE THROAT; TUBE;

EID: 0042329318     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/bja/aeg192     Document Type: Article
Times cited : (76)

References (19)
  • 1
    • 0036841940 scopus 로고    scopus 로고
    • The laryngeal tube compared with the laryngeal mask: Insertion, gas leak pressure and gastric insufflation
    • Asai T, Kawashima A, Hidaka I, Kawachi S. The laryngeal tube compared with the laryngeal mask: insertion, gas leak pressure and gastric insufflation. Br J Anaesth 2002; 89: 729-32
    • (2002) Br. J. Anaesth. , vol.89 , pp. 729-732
    • Asai, T.1    Kawashima, A.2    Hidaka, I.3    Kawachi, S.4
  • 2
    • 0036784844 scopus 로고    scopus 로고
    • A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures
    • Ocker H, Wenzel V, Schmucker P, Steinfath M, Dörges V. A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures. Anesth Analg 2002; 95: 1094-5
    • (2002) Anesth. Analg. , vol.95 , pp. 1094-1095
    • Ocker, H.1    Wenzel, V.2    Schmucker, P.3    Steinfath, M.4    Dörges, V.5
  • 3
    • 0035741152 scopus 로고    scopus 로고
    • The laryngeal mask and VBM laryngeal tube compared during spontaneous ventilation. A pilot study
    • Miller DM, Youkhana I, Pearce AC. The laryngeal mask and VBM laryngeal tube compared during spontaneous ventilation. A pilot study. Eur J Anaesthesiol 2001; 18: 593-8
    • (2001) Eur. J. Anaesthesiol. , vol.18 , pp. 593-598
    • Miller, D.M.1    Youkhana, I.2    Pearce, A.C.3
  • 4
    • 0021792090 scopus 로고
    • A clinical sign to predict difficult tracheal intubation: A prospective study
    • Mallampati SR, Gatt SP, Gugino LD, et al. A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J 1985; 32: 429-34
    • (1985) Can. Anaesth. Soc. J. , vol.32 , pp. 429-434
    • Mallampati, S.R.1    Gatt, S.P.2    Gugino, L.D.3
  • 5
    • 0023238545 scopus 로고
    • Difficult tracheal intubation: A retrospective study
    • Samsoon GLT, Young JRB. Difficult tracheal intubation: a retrospective study. Anaesthesia 1987; 42: 487-90
    • (1987) Anaesthesia , vol.42 , pp. 487-490
    • Samsoon, G.L.T.1    Young, J.R.B.2
  • 6
    • 0033719585 scopus 로고    scopus 로고
    • Efficacy of the laryngeal tube during intermittent positive pressure ventilation
    • Asai T, Murao K, Shingu K. Efficacy of the laryngeal tube during intermittent positive pressure ventilation. Anaesthesia 2000; 55: 1099-102
    • (2000) Anaesthesia , vol.55 , pp. 1099-1102
    • Asai, T.1    Murao, K.2    Shingu, K.3
  • 7
    • 0004005126 scopus 로고    scopus 로고
    • The Laryngeal Mask Instruction Manual for Anaesthesia
    • Henly-on-Thames, UK: Intavent Research Ltd
    • Brimacombe JR, Brain AIJ, Berry AM. The Laryngeal Mask Instruction Manual for Anaesthesia. Henly-on-Thames, UK: Intavent Research Ltd, 1999
    • (1999)
    • Brimacombe, J.R.1    Brain, A.I.J.2    Berry, A.M.3
  • 8
    • 0033636120 scopus 로고    scopus 로고
    • Cuff volume and size selection with the laryngeal mask
    • Asai T, Brimacombe J. Cuff volume and size selection with the laryngeal mask. Anaesthesia 2000; 55: 1179-84
    • (2000) Anaesthesia , vol.55 , pp. 1179-1184
    • Asai, T.1    Brimacombe, J.2
  • 9
    • 0027996345 scopus 로고
    • The laryngeal mask airway: Its features, effects and role
    • Asai T, Morris S. The laryngeal mask airway: its features, effects and role. Can J Anaesth 1994; 41: 930-60
    • (1994) Can. J. Anaesth. , vol.41 , pp. 930-960
    • Asai, T.1    Morris, S.2
  • 12
    • 0036209037 scopus 로고    scopus 로고
    • A randomized crossover comparison of the Pro-Seal with the classic laryngeal mask airway in unparalysed anaesthetized patients
    • Cook TM, Nolan JP, Verghese C, et al. A randomized crossover comparison of the Pro-Seal with the classic laryngeal mask airway in unparalysed anaesthetized patients. Br J Anaesth 2002; 88: 527-33
    • (2002) Br. J. Anaesth. , vol.88 , pp. 527-533
    • Cook, T.M.1    Nolan, J.P.2    Verghese, C.3
  • 16
    • 0036712121 scopus 로고    scopus 로고
    • A comparison of the laryngeal mask airway ProSeal™ and the laryngeal tube airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation
    • Brimacbome J, Keller C, Brimacombe L. A comparison of the laryngeal mask airway ProSeal™ and the laryngeal tube airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation. Anesth Analg 2002; 95: 770-6
    • (2002) Anesth. Analg. , vol.95 , pp. 770-776
    • Brimacbome, J.1    Keller, C.2    Brimacombe, L.3
  • 17
    • 0035072408 scopus 로고    scopus 로고
    • A new device has to be safe and reliable too
    • Mandal NG, Asai T. A new device has to be safe and reliable too. Anaesthesia 2001; 56: 382
    • (2001) Anaesthesia , vol.56 , pp. 382
    • Mandal, N.G.1    Asai, T.2
  • 18
    • 0032896429 scopus 로고    scopus 로고
    • Laryngo-pharyngeal complaints after use of the laryngeal mask airway
    • Figuerdo E, Vivar-Diago M, Munoz-Blanco F. Laryngo-pharyngeal complaints after use of the laryngeal mask airway. Can J Anaesth 1999; 46: 220-5
    • (1999) Can. J. Anaesth. , vol.46 , pp. 220-225
    • Figuerdo, E.1    Vivar-Diago, M.2    Munoz-Blanco, F.3
  • 19
    • 0032754991 scopus 로고    scopus 로고
    • Complications following the use of the Combitube, tracheal tube and laryngeal mask airway
    • Oczenski W, Krenn H, Dahaba AA, et al. Complications following the use of the Combitube, tracheal tube and laryngeal mask airway. Anaesthesia 1999; 54: 1161-5
    • (1999) Anaesthesia , vol.54 , pp. 1161-1165
    • Oczenski, W.1    Krenn, H.2    Dahaba, A.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.