Electrical detection of C-reactive protein using a single free-standing, thermally controlled piezoresistive microcantilever for highly reproducible and accurate measurements

Author keywords

Biosensor; C reactive protein; Mems; Piezoresistive microcantilever; Reproducibility

Indexed keywords

ASSAYS; BINDING ENERGY; BIOSENSORS; BRIDGE CIRCUITS; DISEASES; MEMS; NANOCANTILEVERS; SENSORS;

EID: 84881235196     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s130809653     Document Type: Article
Times cited : (30)

References (35)
  • 1
    • 3843119792 scopus 로고    scopus 로고
    • Cantilever transducers as a platform for chemical and biological sensors
    • Lavrik, N.V.; Sepaniak, M.J.; Datskos, P.G. Cantilever transducers as a platform for chemical and biological sensors. Rev. Sci. Instrum. 2004, 75, 2229-2253.
    • (2004) Rev. Sci. Instrum , vol.75 , pp. 2229-2253
    • Lavrik, N.V.1    Sepaniak, M.J.2    Datskos, P.G.3
  • 3
    • 14644415474 scopus 로고    scopus 로고
    • Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers
    • Wee, K.W.; Kang, G.Y.; Park, J.; Kang, J.Y.; Yoon, D.S.; Park, J.H.; Kim, T.S. Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers. Biosens. Bioelectron. 2005, 20, 1932-1938
    • (2005) Biosens. Bioelectron , vol.20 , pp. 1932-1938
    • Wee, K.W.1    Kang, G.Y.2    Park, J.3    Kang, J.Y.4    Yoon, D.S.5    Park, J.H.6    Kim, T.S.7
  • 4
    • 0033554758 scopus 로고    scopus 로고
    • Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers
    • Datskos, P.G.; Sauers, I. Detection of 2-mercaptoethanol using gold-coated micromachined cantilevers. Sens. Actuators B 1999, 61, 75-82.
    • (1999) Sens. Actuators B , vol.61 , pp. 75-82
    • Datskos, P.G.1    Sauers, I.2
  • 7
    • 24944439851 scopus 로고    scopus 로고
    • Nanomechanical sensing of DNA sequences using piezoresistive cantilevers
    • Mukhopadhyay, R.; Lorentzen, M.; Kjems, J.; Besenbacher, F. Nanomechanical sensing of DNA sequences using piezoresistive cantilevers. Langmuir 2005, 21, 8400-8408.
    • (2005) Langmuir , vol.21 , pp. 8400-8408
    • Mukhopadhyay, R.1    Lorentzen, M.2    Kjems, J.3    Besenbacher, F.4
  • 9
    • 0001319301 scopus 로고    scopus 로고
    • Enhanced chemi-mechanical transduction at nanostructured interfaces
    • Lavrik, N.V.; Tipple, C.A.; Sepaniak, M.J.; Datskos, P.G. Enhanced chemi-mechanical transduction at nanostructured interfaces. Chem. Phys. Lett. 2001, 336, 371-376.
    • (2001) Chem. Phys. Lett , vol.336 , pp. 371-376
    • Lavrik, N.V.1    Tipple, C.A.2    Sepaniak, M.J.3    Datskos, P.G.4
  • 10
    • 33645369584 scopus 로고    scopus 로고
    • Detection of explosive compounds with the use of microcantilevers with nanoporous coatings
    • Datskos, P.G.; Lavrik, N.V.; Sepaniak, M.J. Detection of explosive compounds with the use of microcantilevers with nanoporous coatings. Sens. Lett. 2003, 1, 25-32.
    • (2003) Sens. Lett , vol.1 , pp. 25-32
    • Datskos, P.G.1    Lavrik, N.V.2    Sepaniak, M.J.3
  • 11
    • 0347758352 scopus 로고    scopus 로고
    • Glucose biosensor based on the microcantilever
    • Pei, J.; Tian, F.; Thundat, T. Glucose biosensor based on the microcantilever. Anal. Chem. 2003, 76, 292-297.
    • (2003) Anal. Chem , vol.76 , pp. 292-297
    • Pei, J.1    Tian, F.2    Thundat, T.3
  • 12
    • 3042604472 scopus 로고    scopus 로고
    • Real-time PCR based on SYBR-Green I fluorescence: An alternative to the TaqMan assay for a relative quantification of gene rearrangements, gene amplifications and micro gene deletions
    • 10.1186/1472-6750-3-18
    • Ponchel, F.; Toomes, C.; Bransfield, K.; Leong, F.; Douglas, S.; Field, S.; Bell, S.; Combaret, V.; Puisieux, A.; Mighell, A.; et al. Real-time PCR based on SYBR-Green I fluorescence: An alternative to the TaqMan assay for a relative quantification of gene rearrangements, gene amplifications and micro gene deletions. BMC Biotechnol. 2003, 3, doi:10.1186/1472-6750-3-18
    • (2003) BMC Biotechnol , vol.3
    • Ponchel, F.1    Toomes, C.2    Bransfield, K.3    Leong, F.4    Douglas, S.5    Field, S.6    Bell, S.7    Combaret, V.8    Puisieux, A.9    Mighell, A.10
  • 13
    • 4143097105 scopus 로고    scopus 로고
    • Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein
    • Lee, J.H.; Yoon, K.H.; Hwang, K.S.; Park, J.; Ahn, S.; Kim, T.S. Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein. Biosens. Bioelectron. 2004, 20, 269-275.
    • (2004) Biosens. Bioelectron , vol.20 , pp. 269-275
    • Lee, J.H.1    Yoon, K.H.2    Hwang, K.S.3    Park, J.4    Ahn, S.5    Kim, T.S.6
  • 14
    • 2442484422 scopus 로고    scopus 로고
    • 3 thin film microcantilever for the detection of C-reactive protein
    • 3 thin film microcantilever for the detection of C-reactive protein. Appl. Phys. Lett. 2004, 84, 3187-3189.
    • (2004) Appl. Phys. Lett , vol.84 , pp. 3187-3189
    • Lee, J.H.1    Kim, T.S.2    Yoon, K.H.3
  • 15
    • 59949096897 scopus 로고    scopus 로고
    • Nanogram per milliliter-level immunologic detection of alpha-fetoprotein with integrated rotating-resonance microcantilevers for early-stage diagnosis of heptocellular carcinoma
    • Liu, Y.; Li, X.; Zhang, Z.; Zuo, G.; Cheng, Z.; Yu, H. Nanogram per milliliter-level immunologic detection of alpha-fetoprotein with integrated rotating-resonance microcantilevers for early-stage diagnosis of heptocellular carcinoma. Biomed. Microdevices 2009, 11, 183-191.
    • (2009) Biomed. Microdevices , vol.11 , pp. 183-191
    • Liu, Y.1    Li, X.2    Zhang, Z.3    Zuo, G.4    Cheng, Z.5    Yu, H.6
  • 16
    • 51649092992 scopus 로고    scopus 로고
    • C-reactive protein and coronary heart disease: A critical review
    • Casas, J.P.; Shah, T.; Hingorani, A.D.; Danesh, J.; Pepys, M.B. C-reactive protein and coronary heart disease: A critical review. J. Int. Med. 2008, 264, 295-314.
    • (2008) J. Int. Med , vol.264 , pp. 295-314
    • Casas, J.P.1    Shah, T.2    Hingorani, A.D.3    Danesh, J.4    Pepys, M.B.5
  • 17
    • 70349742564 scopus 로고    scopus 로고
    • C-reactive protein as a risk factor for coronary heart disease: A systematic review and meta-analyses for the US preventive services task force
    • Buckley, D.I.; Fu, R.; Freeman, M.; Rogers, K.; Helfand, M. C-reactive protein as a risk factor for coronary heart disease: A systematic review and meta-analyses for the US preventive services task force. Ann. Int. Med. 2009, 151, 483-495.
    • (2009) Ann. Int. Med , vol.151 , pp. 483-495
    • Buckley, D.I.1    Fu, R.2    Freeman, M.3    Rogers, K.4    Helfand, M.5
  • 20
    • 0033977788 scopus 로고    scopus 로고
    • Environmental sensors based on micromachined cantilevers with integrated read-out
    • Boisen, A.; Thaysen, J.; Jensenius, H.; Hansen, O. Environmental sensors based on micromachined cantilevers with integrated read-out. Ultramicroscopy 2000, 82, 11-16.
    • (2000) Ultramicroscopy , vol.82 , pp. 11-16
    • Boisen, A.1    Thaysen, J.2    Jensenius, H.3    Hansen, O.4
  • 21
    • 33645085279 scopus 로고    scopus 로고
    • MOSFET-embedded microcantilevers for measuring deflection in biomolecular sensor
    • Shekhawat, G.; Tark, S.-H.; Dravid, V.P. MOSFET-embedded microcantilevers for measuring deflection in biomolecular sensor. Science 2006, 311, 1592-1595.
    • (2006) Science , vol.311 , pp. 1592-1595
    • Shekhawat, G.1    Tark, S.-H.2    Dravid, V.P.3
  • 24
    • 0035253067 scopus 로고    scopus 로고
    • Detection of pH variation using modified microcantilever sensors
    • Ji, H.F.; Hansen, K.M.; Hu, Z.; Thundat, T. Detection of pH variation using modified microcantilever sensors. Sens. Actuators B 2001, 72, 233-238.
    • (2001) Sens. Actuators B , vol.72 , pp. 233-238
    • Ji, H.F.1    Hansen, K.M.2    Hu, Z.3    Thundat, T.4
  • 25
    • 34748914797 scopus 로고    scopus 로고
    • A piezoresistive microcantilever array for surface stress measurement: Curvature model and fabrication
    • Choudhury, A.; Hesketh, P.; Thundat, T.; Hu, Z. A piezoresistive microcantilever array for surface stress measurement: Curvature model and fabrication. J. Micromech. Microeng. 2007, 17, 2065-2076.
    • (2007) J. Micromech. Microeng , vol.17 , pp. 2065-2076
    • Choudhury, A.1    Hesketh, P.2    Thundat, T.3    Hu, Z.4
  • 27
    • 20844443122 scopus 로고    scopus 로고
    • Cantilever surface stress sensors with single-crystalline silicon piezoresistors
    • 10.1063/1.1900299
    • Rasmussen, P.A.; Hansen, O.; Boisen, A. Cantilever surface stress sensors with single-crystalline silicon piezoresistors. Appl. Phys. Lett. 2005, 86, doi:10.1063/1.1900299
    • (2005) Appl. Phys. Lett , vol.86
    • Rasmussen, P.A.1    Hansen, O.2    Boisen, A.3
  • 28
    • 0034696599 scopus 로고    scopus 로고
    • A novel self-assembled monolayer (SAM) coated microcantilever for low level caesium detection
    • Ji, H.; Dabestani, R.; Brown, G.; Britt, P. A novel self-assembled monolayer (SAM) coated microcantilever for low level caesium detection. Chem. Commun. 2000, 6, 457-458.
    • (2000) Chem. Commun , vol.6 , pp. 457-458
    • Ji, H.1    Dabestani, R.2    Brown, G.3    Britt, P.4
  • 29
    • 0035103498 scopus 로고    scopus 로고
    • High-sensitivity C-reactive protein: A novel and promising marker of coronary heart disease
    • Rifai, N.; Ridker, P.M. High-sensitivity C-reactive protein: A novel and promising marker of coronary heart disease. Clin. Chem. 2001, 47, 403-411.
    • (2001) Clin. Chem , vol.47 , pp. 403-411
    • Rifai, N.1    Ridker, P.M.2
  • 30
    • 0004274707 scopus 로고
    • BIACORE, Pharmacia Biosensor AB: Uppsala, Sweden
    • BIACORE. BIAtechnology Handbook; Pharmacia Biosensor AB: Uppsala, Sweden, 1994.
    • (1994) BIAtechnology Handbook
  • 32
    • 84455202477 scopus 로고    scopus 로고
    • Binding kinetics of grouper nervous necrosis viruses with functionalized antimicrobial peptides by nanomechanical detection
    • Kuan, S.; Chi, S.-C.; Cheng, Y.-J.; Chia, T.-J.; Huang, L.-S. Binding kinetics of grouper nervous necrosis viruses with functionalized antimicrobial peptides by nanomechanical detection. Biosens. Bioelectron. 2012, 31, 116-123.
    • (2012) Biosens. Bioelectron , vol.31 , pp. 116-123
    • Kuan, S.1    Chi, S.-C.2    Cheng, Y.-J.3    Chia, T.-J.4    Huang, L.-S.5
  • 35
    • 77957950093 scopus 로고    scopus 로고
    • Detection of C-reactive protein in evanescent wave field using microparticle-tracking velocimetry
    • Fan, Y.-J.; Sheen, H.-J.; Liu, Y.-H.; Tsai, J.-F.; Wu, T.-H.; Wu, K.-C.; Lin, S. Detection of C-reactive protein in evanescent wave field using microparticle-tracking velocimetry. Langmuir 2010, 26, 13751-13754.
    • (2010) Langmuir , vol.26 , pp. 13751-13754
    • Fan, Y.-J.1    Sheen, H.-J.2    Liu, Y.-H.3    Tsai, J.-F.4    Wu, T.-H.5    Wu, K.-C.6    Lin, S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.