메뉴 건너뛰기




Volumn 20, Issue 10 SPEC. ISS., 2005, Pages 1932-1938

Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers

Author keywords

Antibody; Antigen; Micro cantilever; Nano mechanics; Piezoresistivity

Indexed keywords

ANTIBODIES; ANTIGENS; BIOMARKERS; CARDIOLOGY; CONCENTRATION (PROCESS); DISEASES; PROTEINS; STRESSES; TUMORS;

EID: 14644415474     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bios.2004.09.023     Document Type: Conference Paper
Times cited : (251)

References (25)
  • 3
    • 0028095919 scopus 로고
    • The acute phase response
    • H. Baumann, and J. Gauldie The acute phase response Immunol. Today 15 2 1994 74 80
    • (1994) Immunol. Today , vol.15 , Issue.2 , pp. 74-80
    • Baumann, H.1    Gauldie, J.2
  • 5
    • 0033977788 scopus 로고    scopus 로고
    • Environmental sensors based on micromachined cantilevers with integrated read-out
    • A. Boisen, J. Thaysen, H. Jensenius, and O. Hansen Environmental sensors based on micromachined cantilevers with integrated read-out Ultramicroscopy 82 2000 11 16
    • (2000) Ultramicroscopy , vol.82 , pp. 11-16
    • Boisen, A.1    Thaysen, J.2    Jensenius, H.3    Hansen, O.4
  • 6
    • 34347209835 scopus 로고
    • Calculation of thermal noise in atomic force microscopy
    • H.J. Butt, and M. Jaschke Calculation of thermal noise in atomic force microscopy Nanotechnology 6 1 1995 1 7
    • (1995) Nanotechnology , vol.6 , Issue.1 , pp. 1-7
    • Butt, H.J.1    Jaschke, M.2
  • 7
    • 0242667569 scopus 로고    scopus 로고
    • Detection of heavy metal ions using protein-functionalized micro-cantilever sensors
    • S. Cherian, R.K. Gupta, B.C. Mullin, and T. Thundat Detection of heavy metal ions using protein-functionalized micro-cantilever sensors Biosens. Bioelectron. 19 2003 411 416
    • (2003) Biosens. Bioelectron. , vol.19 , pp. 411-416
    • Cherian, S.1    Gupta, R.K.2    Mullin, B.C.3    Thundat, T.4
  • 10
    • 0036178311 scopus 로고    scopus 로고
    • In situ detection of calcium ions with chemically modified micro-cantilevers
    • H.-F. Ji, and T. Thundat In situ detection of calcium ions with chemically modified micro-cantilevers Biosens. Bioelectron. 17 2002 337 343
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 337-343
    • Ji, H.-F.1    Thundat, T.2
  • 11
    • 0242499140 scopus 로고    scopus 로고
    • Investigation of the antigen antibody reaction between anti-bovine serum albumin (a-BSA) and bovine serum albumin (BSA) using piezoresistive micro-cantilever based sensors
    • A. Kooser, K. Manygoats, M.P. Eastman, and T.L. Porter Investigation of the antigen antibody reaction between anti-bovine serum albumin (a-BSA) and bovine serum albumin (BSA) using piezoresistive micro-cantilever based sensors Biosens. Bioelectron. 19 2003 503 508
    • (2003) Biosens. Bioelectron. , vol.19 , pp. 503-508
    • Kooser, A.1    Manygoats, K.2    Eastman, M.P.3    Porter, T.L.4
  • 12
    • 0018095135 scopus 로고
    • Control of the acute phase response: C-reactive protein synthesis and secretion by hepatocytes during acute inflammation in the rabbits
    • I. Kushner, and G. Feldmann Control of the acute phase response: C-reactive protein synthesis and secretion by hepatocytes during acute inflammation in the rabbits J. Exp. Med. 148 2 1978 466 477
    • (1978) J. Exp. Med. , vol.148 , Issue.2 , pp. 466-477
    • Kushner, I.1    Feldmann, G.2
  • 13
    • 0346887185 scopus 로고    scopus 로고
    • ProteoChip: A highly sensitive protein microarray prepared by a novel method of protein immobilization for application of protein-protein interaction studies
    • Y. Lee, E.K. Lee, Y.W. Cho, T. Matsui, I.C. Kang, T.S. Kim, and M.H. Han ProteoChip: a highly sensitive protein microarray prepared by a novel method of protein immobilization for application of protein-protein interaction studies Proteomics 3 2003 2289 2304
    • (2003) Proteomics , vol.3 , pp. 2289-2304
    • Lee, Y.1    Lee, E.K.2    Cho, Y.W.3    Matsui, T.4    Kang, I.C.5    Kim, T.S.6    Han, M.H.7
  • 14
    • 0020332423 scopus 로고
    • Serum C-reactive protein levels in disease
    • J.J. Morley, and I. Kushner Serum C-reactive protein levels in disease Ann. N Y Acad. Sci. 389 1982 406 418
    • (1982) Ann. N Y Acad. Sci. , vol.389 , pp. 406-418
    • Morley, J.J.1    Kushner, I.2
  • 15
    • 0033554783 scopus 로고    scopus 로고
    • Sensing of biological substance based on the bending of microfabricated cantilevers
    • R. Raiteri, G. Nelles, H.-J. Butt, W. Knoll, and P. Skladal Sensing of biological substance based on the bending of microfabricated cantilevers Sens. Actu. B 61 1999 213 217
    • (1999) Sens. Actu. B , vol.61 , pp. 213-217
    • Raiteri, R.1    Nelles, G.2    Butt, H.-J.3    Knoll, W.4    Skladal, P.5
  • 18
    • 0026334099 scopus 로고
    • Plasma neopterin as an adjunct to C-reactive protein in assessment of infection
    • J. Sheldon, P.G. Riches, N. Soni, E. Jurges, M. Gore, G. Dadian, and J.R. Hobbs Plasma neopterin as an adjunct to C-reactive protein in assessment of infection Clin. Chem. 37 12 1991 2038 2042
    • (1991) Clin. Chem. , vol.37 , Issue.12 , pp. 2038-2042
    • Sheldon, J.1    Riches, P.G.2    Soni, N.3    Jurges, E.4    Gore, M.5    Dadian, G.6    Hobbs, J.R.7
  • 19
    • 0000073841 scopus 로고
    • The tension of metallic films deposited by electrolysis
    • G.G. Stoney The tension of metallic films deposited by electrolysis Pro. Poy. Soc. London A Mater. 82 1909 172 175
    • (1909) Pro. Poy. Soc. London a Mater. , vol.82 , pp. 172-175
    • Stoney, G.G.1
  • 21
    • 0000023102 scopus 로고
    • Piezoresistive properties of silicon diffused layers
    • O.N. Tufte, and E.L. Stelzer Piezoresistive properties of silicon diffused layers J. Appl. Phys. 34 1963 313 318
    • (1963) J. Appl. Phys. , vol.34 , pp. 313-318
    • Tufte, O.N.1    Stelzer, E.L.2
  • 24
    • 0026135563 scopus 로고
    • C-reactive protein: A critical review
    • B. Young, M. Glesson, and A. Cripps C-reactive protein: a critical review Pathology 23 2 1991 118 124
    • (1991) Pathology , vol.23 , Issue.2 , pp. 118-124
    • Young, B.1    Glesson, M.2    Cripps, A.3
  • 25
    • 0037113006 scopus 로고    scopus 로고
    • Optimization of sensitivity and noise in piezoresistive cantilevers
    • X. Yu, J. Thaysen, O. Hansen, and A. Boisen Optimization of sensitivity and noise in piezoresistive cantilevers J. Appl. Phys. 92 2002 6296 6301
    • (2002) J. Appl. Phys. , vol.92 , pp. 6296-6301
    • Yu, X.1    Thaysen, J.2    Hansen, O.3    Boisen, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.