메뉴 건너뛰기




Volumn 13, Issue SUPPLL. 1, 2007, Pages

Contrast-enhanced magnetic resonance angiography: Current status, theoretical limitations and future potential

Author keywords

Atherosclerosis; Gadolinium contrast agent; Gadolinium contrast agents; Magnetic resonance angiography; MR vascular studies

Indexed keywords

ARTICLE; CLINICAL PRACTICE; CONTRAST ENHANCEMENT; MAGNETIC RESONANCE ANGIOGRAPHY; NON INVASIVE MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; VASCULAR DISEASE;

EID: 37349034944     PISSN: 10788174     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radi.2007.09.002     Document Type: Article
Times cited : (3)

References (101)
  • 1
    • 0026564750 scopus 로고
    • Arteriographic complications in the DSA era
    • Waugh J.R., and Sacharia N. Arteriographic complications in the DSA era. Radiology 182 (1992) 243-246
    • (1992) Radiology , vol.182 , pp. 243-246
    • Waugh, J.R.1    Sacharia, N.2
  • 2
    • 33846231022 scopus 로고    scopus 로고
    • Guidelines for noninvasive vascular laboratory testing: a report from the American Society of Echocardiography and the Society for Vascular Medicine and Biology
    • Gerhard-Herman M., Gardin J.M., Jaff M., Mohler E., Roman M., Naqvi T.Z., et al. Guidelines for noninvasive vascular laboratory testing: a report from the American Society of Echocardiography and the Society for Vascular Medicine and Biology. Vasc Med 11 3 (2006 Nov) 183-200
    • (2006) Vasc Med , vol.11 , Issue.3 , pp. 183-200
    • Gerhard-Herman, M.1    Gardin, J.M.2    Jaff, M.3    Mohler, E.4    Roman, M.5    Naqvi, T.Z.6
  • 3
    • 33744811674 scopus 로고    scopus 로고
    • Practical noninvasive neurovascular imaging of the neck arteries in patients with stroke, transient ischemic attack, and suspected arterial disease that may lead to ischemia, infarction, or flow abnormalities
    • Brobeck B.R., Forero N.P., and Romero J.M. Practical noninvasive neurovascular imaging of the neck arteries in patients with stroke, transient ischemic attack, and suspected arterial disease that may lead to ischemia, infarction, or flow abnormalities. Semin Ultrasound CT MR 27 3 (2006 Jun) 177-193
    • (2006) Semin Ultrasound CT MR , vol.27 , Issue.3 , pp. 177-193
    • Brobeck, B.R.1    Forero, N.P.2    Romero, J.M.3
  • 4
    • 0024383809 scopus 로고
    • Three-dimensional time-of-flight magnetic resonance angiography using spin-saturation
    • Dumoulin C.L., Cline H.E., Souza S.P., Wagle W.A., and Walker M.F. Three-dimensional time-of-flight magnetic resonance angiography using spin-saturation. Magn Reson Med 11 (1989) 139-149
    • (1989) Magn Reson Med , vol.11 , pp. 139-149
    • Dumoulin, C.L.1    Cline, H.E.2    Souza, S.P.3    Wagle, W.A.4    Walker, M.F.5
  • 5
    • 0024316791 scopus 로고
    • The salient features of MR angiography
    • Haacke E.M., and Masaryk T.J. The salient features of MR angiography. Radiology 173 (1989) 611-612
    • (1989) Radiology , vol.173 , pp. 611-612
    • Haacke, E.M.1    Masaryk, T.J.2
  • 6
    • 0025999768 scopus 로고
    • Flow, radiofrequency, pulse sequences, and gradient magnetic fields: basic interactions and adaptations to angiographic imaging
    • Masaryk T.J., Tkach J., and Glicklich M. Flow, radiofrequency, pulse sequences, and gradient magnetic fields: basic interactions and adaptations to angiographic imaging. Top Magn Reson Imaging 3 (1991) 1-11
    • (1991) Top Magn Reson Imaging , vol.3 , pp. 1-11
    • Masaryk, T.J.1    Tkach, J.2    Glicklich, M.3
  • 7
    • 0000517352 scopus 로고
    • Time of flight magnetic resonance angiography
    • Keller P. Time of flight magnetic resonance angiography. Neuroimaging Clin N Am 4 (1992) 639-656
    • (1992) Neuroimaging Clin N Am , vol.4 , pp. 639-656
    • Keller, P.1
  • 8
    • 0029351291 scopus 로고
    • Phase contrast MR angiography techniques
    • Dumoulin C.L. Phase contrast MR angiography techniques. Magn Reson Imaging Clin N Am 3 (1995) 399-411
    • (1995) Magn Reson Imaging Clin N Am , vol.3 , pp. 399-411
    • Dumoulin, C.L.1
  • 9
    • 0032977857 scopus 로고    scopus 로고
    • Black-blood MR angiography. Techniques and clinical applications
    • Jara H., and Barish M.A. Black-blood MR angiography. Techniques and clinical applications. Magn Reson Imaging Clin N Am 7 (1999) 303-317
    • (1999) Magn Reson Imaging Clin N Am , vol.7 , pp. 303-317
    • Jara, H.1    Barish, M.A.2
  • 10
    • 0031089224 scopus 로고    scopus 로고
    • Magnetic resonance angiography in stenosing-occlusive diseases of the carotid arteries: 3D with time of flight versus 3D with phase contrast
    • Scarabino T., Carriero A., Magarelli N., Nemore F., Florio F., D'Angelo V., et al. Magnetic resonance angiography in stenosing-occlusive diseases of the carotid arteries: 3D with time of flight versus 3D with phase contrast. Radiol Med (Torino) 93 (1997) 214-217
    • (1997) Radiol Med (Torino) , vol.93 , pp. 214-217
    • Scarabino, T.1    Carriero, A.2    Magarelli, N.3    Nemore, F.4    Florio, F.5    D'Angelo, V.6
  • 11
    • 0028351567 scopus 로고
    • Gadolinium-enhanced MR aortography
    • Prince M.R. Gadolinium-enhanced MR aortography. Radiology 191 1 (1994 Apr) 155-164
    • (1994) Radiology , vol.191 , Issue.1 , pp. 155-164
    • Prince, M.R.1
  • 12
    • 0028845732 scopus 로고
    • Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches
    • Prince M.R., Narasimham D.L., Stanley J.C., Chenevert T.L., Williams D.M., Marx M.V., et al. Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology 197 3 (1995 Dec) 785-792
    • (1995) Radiology , vol.197 , Issue.3 , pp. 785-792
    • Prince, M.R.1    Narasimham, D.L.2    Stanley, J.C.3    Chenevert, T.L.4    Williams, D.M.5    Marx, M.V.6
  • 15
    • 0029881297 scopus 로고    scopus 로고
    • Body MR angiography with gadolinium contrast agents
    • Prince M.R. Body MR angiography with gadolinium contrast agents. Magn Reson Imaging Clin N Am 4 1 (1996 Feb) 11-24
    • (1996) Magn Reson Imaging Clin N Am , vol.4 , Issue.1 , pp. 11-24
    • Prince, M.R.1
  • 16
    • 0030183445 scopus 로고    scopus 로고
    • The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality
    • Maki J.H., Prince M.R., Londy F.J., and Chenevert T.L. The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality. J Magn Reson Imaging 6 4 (1996 Jul-Aug) 642-651
    • (1996) J Magn Reson Imaging , vol.6 , Issue.4 , pp. 642-651
    • Maki, J.H.1    Prince, M.R.2    Londy, F.J.3    Chenevert, T.L.4
  • 18
    • 0031421928 scopus 로고    scopus 로고
    • Gadolinium-enhanced MR angiography of visceral arteries in patients with suspected chronic mesenteric ischemia
    • Meaney J.F., Prince M.R., Nostrant T.T., and Stanley J.C. Gadolinium-enhanced MR angiography of visceral arteries in patients with suspected chronic mesenteric ischemia. J Magn Reson Imaging 7 1 (1997 Jan-Feb) 171-176
    • (1997) J Magn Reson Imaging , vol.7 , Issue.1 , pp. 171-176
    • Meaney, J.F.1    Prince, M.R.2    Nostrant, T.T.3    Stanley, J.C.4
  • 19
    • 0032470453 scopus 로고    scopus 로고
    • Why inject contrast for magnetic resonance angiography?
    • Prince M.R. Why inject contrast for magnetic resonance angiography?. Invest Radiol 33 9 (1998 Sep) 483-484
    • (1998) Invest Radiol , vol.33 , Issue.9 , pp. 483-484
    • Prince, M.R.1
  • 20
    • 0031810805 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography: theory and optimization
    • Prince M.R. Contrast-enhanced MR angiography: theory and optimization. Magn Reson Imaging Clin N Am 6 2 (1998 May) 257-267
    • (1998) Magn Reson Imaging Clin N Am , vol.6 , Issue.2 , pp. 257-267
    • Prince, M.R.1
  • 21
    • 0030867229 scopus 로고    scopus 로고
    • Hemodynamically significant atherosclerotic renal artery stenosis: MR angiographic features
    • Prince M.R., Schoenberg S.O., Ward J.S., Londy F.J., Wakefield T.W., and Stanley J.C. Hemodynamically significant atherosclerotic renal artery stenosis: MR angiographic features. Radiology 205 (1997) 128-136
    • (1997) Radiology , vol.205 , pp. 128-136
    • Prince, M.R.1    Schoenberg, S.O.2    Ward, J.S.3    Londy, F.J.4    Wakefield, T.W.5    Stanley, J.C.6
  • 22
    • 0036137599 scopus 로고    scopus 로고
    • Morphologic and functional magnetic resonance imaging of renal artery stenosis: a multireader tricenter study
    • Schoenberg S.O., Knopp M.V., Londy F., Frishnan S., Zuna I., Lang N., et al. Morphologic and functional magnetic resonance imaging of renal artery stenosis: a multireader tricenter study. J Am Soc Nephrol 13 (2002) 158-169
    • (2002) J Am Soc Nephrol , vol.13 , pp. 158-169
    • Schoenberg, S.O.1    Knopp, M.V.2    Londy, F.3    Frishnan, S.4    Zuna, I.5    Lang, N.6
  • 23
    • 37349017711 scopus 로고    scopus 로고
    • Leiner T, Nelemans PJ, de Haan MW, de Leeuw P, van Engelshoven JMA, Vasbinder GBC. Addition of phase-contrast data to anatomical evaluation substantially improves the diagnostic accuracy of dynamic contrast-enhanced renal MR angiography for the detection of renal artery stenosis. Radiological Society of North America Annual Meeting Abstract Book 2006. p. 540.
  • 24
    • 0025052315 scopus 로고
    • Three-dimensional time-of-flight MR angiography in the evaluation of cerebral aneurysms
    • Sevick R.J., Tsuruda J.S., and Schmalbrock P. Three-dimensional time-of-flight MR angiography in the evaluation of cerebral aneurysms. J Comput Assist Tomogr 14 6 (1990 Nov-Dec) 874-881
    • (1990) J Comput Assist Tomogr , vol.14 , Issue.6 , pp. 874-881
    • Sevick, R.J.1    Tsuruda, J.S.2    Schmalbrock, P.3
  • 25
    • 0028197357 scopus 로고
    • Detection of intracranial aneurysms by three-dimensional time-of-flight magnetic resonance angiography
    • Horikoshi T., Fukamachi A., Nishi H., and Fukasawa I. Detection of intracranial aneurysms by three-dimensional time-of-flight magnetic resonance angiography. Neuroradiology 36 3 (1994 Apr) 203-207
    • (1994) Neuroradiology , vol.36 , Issue.3 , pp. 203-207
    • Horikoshi, T.1    Fukamachi, A.2    Nishi, H.3    Fukasawa, I.4
  • 28
    • 0033854613 scopus 로고    scopus 로고
    • MR-angiography: the role of contrast agents
    • Goyen M., Ruehm S.G., and Debatin J.F. MR-angiography: the role of contrast agents. Eur J Radiol 34 (2000) 247-256
    • (2000) Eur J Radiol , vol.34 , pp. 247-256
    • Goyen, M.1    Ruehm, S.G.2    Debatin, J.F.3
  • 29
    • 0032731661 scopus 로고    scopus 로고
    • Principles of contrast-enhanced MR angiography: basic and clinical applications
    • Laub G. Principles of contrast-enhanced MR angiography: basic and clinical applications. Magn Reson Imaging Clin N Am 7 (1999) 783-795
    • (1999) Magn Reson Imaging Clin N Am , vol.7 , pp. 783-795
    • Laub, G.1
  • 30
    • 0031227469 scopus 로고    scopus 로고
    • Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography
    • Davis C.P., Hany T.F., Wildermuth S., Schmidt M., and Debatin J.F. Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography. RadioGraphics 17 (1997) 1061-1077
    • (1997) RadioGraphics , vol.17 , pp. 1061-1077
    • Davis, C.P.1    Hany, T.F.2    Wildermuth, S.3    Schmidt, M.4    Debatin, J.F.5
  • 31
    • 0030945180 scopus 로고    scopus 로고
    • Contrast-enhanced abdominal MR angiography: optimization of imaging delay time by automating the detection of contrast material arrival in the aorta
    • Prince M.R., Chenevert T.L., Foo T.K., Londy F.J., Ward J.S., and Maki J.H. Contrast-enhanced abdominal MR angiography: optimization of imaging delay time by automating the detection of contrast material arrival in the aorta. Radiology 203 (1997) 109-114
    • (1997) Radiology , vol.203 , pp. 109-114
    • Prince, M.R.1    Chenevert, T.L.2    Foo, T.K.3    Londy, F.J.4    Ward, J.S.5    Maki, J.H.6
  • 32
    • 0036829410 scopus 로고    scopus 로고
    • Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience
    • Willinek W.A., Gieseke J., Conrad R., Strunk H., Hoogeveen R., von Falkenhausen M., et al. Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology 225 (2002) 583-588
    • (2002) Radiology , vol.225 , pp. 583-588
    • Willinek, W.A.1    Gieseke, J.2    Conrad, R.3    Strunk, H.4    Hoogeveen, R.5    von Falkenhausen, M.6
  • 37
    • 37349006286 scopus 로고    scopus 로고
    • High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0 T: a feasibility study
    • [epub]
    • Willinek W.A., Bayer T., Gieseke J., von Falkenhausen M., Sommer T., Hoogeveen R., et al. High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0 T: a feasibility study. Eur Radiol (2006 Aug 30) [epub]
    • (2006) Eur Radiol
    • Willinek, W.A.1    Bayer, T.2    Gieseke, J.3    von Falkenhausen, M.4    Sommer, T.5    Hoogeveen, R.6
  • 38
    • 33845904906 scopus 로고    scopus 로고
    • Ultrafast time-resolved contrast-enhanced 3D pulmonary venous cardiovascular magnetic resonance angiography using SENSE combined with CENTRA-Keyhole
    • Korperich H., Gieseke J., Esdorn H., Peterschroder A., Hoogeveen R., Barth P., et al. Ultrafast time-resolved contrast-enhanced 3D pulmonary venous cardiovascular magnetic resonance angiography using SENSE combined with CENTRA-Keyhole. J Cardiovasc Magn Reson 9 (2007) 77-87
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 77-87
    • Korperich, H.1    Gieseke, J.2    Esdorn, H.3    Peterschroder, A.4    Hoogeveen, R.5    Barth, P.6
  • 39
    • 0035909055 scopus 로고    scopus 로고
    • Diagnostic tests for renal artery stenosis in patients suspected of having renovascular hypertension: a meta-analysis
    • Vasbinder G.B., Nelemans P.J., Kessels A.G., Kroon A.A., de Leeuw P.W., and van Engelshoven J.M. Diagnostic tests for renal artery stenosis in patients suspected of having renovascular hypertension: a meta-analysis. Ann Intern Med 135 (2001) 401-411
    • (2001) Ann Intern Med , vol.135 , pp. 401-411
    • Vasbinder, G.B.1    Nelemans, P.J.2    Kessels, A.G.3    Kroon, A.A.4    de Leeuw, P.W.5    van Engelshoven, J.M.6
  • 40
    • 0036665158 scopus 로고    scopus 로고
    • Magnetic resonance angiography for the diagnosis of renal artery stenosis: a meta-analysis
    • Tan K.T., van Beek E.J., Brown P.W., van Delden O.M., Tijssen J., and Ramsay L.E. Magnetic resonance angiography for the diagnosis of renal artery stenosis: a meta-analysis. Clin Radiol 57 (2002) 617-624
    • (2002) Clin Radiol , vol.57 , pp. 617-624
    • Tan, K.T.1    van Beek, E.J.2    Brown, P.W.3    van Delden, O.M.4    Tijssen, J.5    Ramsay, L.E.6
  • 41
    • 7244247159 scopus 로고    scopus 로고
    • Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis
    • Vasbinder G.B., Nelemans P.J., Kessels A.G., Kroon A.A., Maki J.H., Leiner T., et al. Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis. Ann Intern Med 141 9 (2004) 674-682
    • (2004) Ann Intern Med , vol.141 , Issue.9 , pp. 674-682
    • Vasbinder, G.B.1    Nelemans, P.J.2    Kessels, A.G.3    Kroon, A.A.4    Maki, J.H.5    Leiner, T.6
  • 43
    • 17644381276 scopus 로고    scopus 로고
    • High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: comparison with digital subtraction angiography and US
    • Schoenberg S.O., Rieger J., Weber C.H., Michaely H.J., Waggershauser T., Ittrich C., et al. High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: comparison with digital subtraction angiography and US. Radiology 235 (2005) 687-698
    • (2005) Radiology , vol.235 , pp. 687-698
    • Schoenberg, S.O.1    Rieger, J.2    Weber, C.H.3    Michaely, H.J.4    Waggershauser, T.5    Ittrich, C.6
  • 44
    • 33744519406 scopus 로고    scopus 로고
    • Technology insight: clinical role of magnetic resonance angiography in the diagnosis and management of renal artery stenosis
    • Dellegrottaglie S., Sanz J., and Rajagopalan S. Technology insight: clinical role of magnetic resonance angiography in the diagnosis and management of renal artery stenosis. Nat Clin Pract Cardiovasc Med 3 (2006) 329-338
    • (2006) Nat Clin Pract Cardiovasc Med , vol.3 , pp. 329-338
    • Dellegrottaglie, S.1    Sanz, J.2    Rajagopalan, S.3
  • 45
    • 31144435889 scopus 로고    scopus 로고
    • Renal artery stenosis: functional assessment with dynamic MR perfusion measurements - feasibility study
    • Michaely H.J., Schoenberg S.O., Oesingmann N., Ittrich C., Buhlig C., Friedrich D., et al. Renal artery stenosis: functional assessment with dynamic MR perfusion measurements - feasibility study. Radiology 238 (2006) 586-596
    • (2006) Radiology , vol.238 , pp. 586-596
    • Michaely, H.J.1    Schoenberg, S.O.2    Oesingmann, N.3    Ittrich, C.4    Buhlig, C.5    Friedrich, D.6
  • 46
    • 0031908601 scopus 로고    scopus 로고
    • Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography
    • Ho K.Y., Leiner T., de Haan M.W., Kessels A.G., Kitslaar P.J., and van Engelshoven J.M. Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography. Radiology 206 3 (1998 Mar) 683-692
    • (1998) Radiology , vol.206 , Issue.3 , pp. 683-692
    • Ho, K.Y.1    Leiner, T.2    de Haan, M.W.3    Kessels, A.G.4    Kitslaar, P.J.5    van Engelshoven, J.M.6
  • 47
    • 0032930455 scopus 로고    scopus 로고
    • Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience
    • Meaney J.F., Ridgway J.P., Chakraverty S., Robertson I., Kessel D., Radjenovic A., et al. Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience. Radiology 211 1 (1999 Apr) 59-67
    • (1999) Radiology , vol.211 , Issue.1 , pp. 59-67
    • Meaney, J.F.1    Ridgway, J.P.2    Chakraverty, S.3    Robertson, I.4    Kessel, D.5    Radjenovic, A.6
  • 48
    • 0032617946 scopus 로고    scopus 로고
    • MR angiography of run-off vessels
    • Ho K.Y., Leiner T., and van Engelshoven J.M. MR angiography of run-off vessels. Eur Radiol 9 7 (1999) 1285-1289
    • (1999) Eur Radiol , vol.9 , Issue.7 , pp. 1285-1289
    • Ho, K.Y.1    Leiner, T.2    van Engelshoven, J.M.3
  • 49
    • 0037743429 scopus 로고    scopus 로고
    • Magnetic resonance angiography of the peripheral arteries: current status
    • Meaney J.F. Magnetic resonance angiography of the peripheral arteries: current status. Eur Radiol 13 (2003) 836-852
    • (2003) Eur Radiol , vol.13 , pp. 836-852
    • Meaney, J.F.1
  • 50
    • 33746396046 scopus 로고    scopus 로고
    • Routine use of three-dimensional contrast-enhanced moving-table MR angiography in patients with peripheral arterial occlusive disease: comparison with selective digital subtraction angiography
    • Deutschmann H.A., Schoellnast H., Portugaller H.R., Preidler K.W., Reittner P., Tillich M., et al. Routine use of three-dimensional contrast-enhanced moving-table MR angiography in patients with peripheral arterial occlusive disease: comparison with selective digital subtraction angiography. Cardiovasc Intervent Radiol 29 (2006) 762-770
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 762-770
    • Deutschmann, H.A.1    Schoellnast, H.2    Portugaller, H.R.3    Preidler, K.W.4    Reittner, P.5    Tillich, M.6
  • 52
    • 0037062132 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study
    • Oudkerk M., van Beek E.J., Wielopolski P., van Ooijen P.M., Brouwers-Kuyper E.M., Bongaerts A.H., et al. Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study. Lancet 359 9318 (2002 May 11) 1643-1647
    • (2002) Lancet , vol.359 , Issue.9318 , pp. 1643-1647
    • Oudkerk, M.1    van Beek, E.J.2    Wielopolski, P.3    van Ooijen, P.M.4    Brouwers-Kuyper, E.M.5    Bongaerts, A.H.6
  • 53
    • 22544439311 scopus 로고    scopus 로고
    • Normal anterior spinal arteries within the cervical region: high-spatial-resolution contrast-enhanced three-dimensional MR angiography
    • Sheehy N.P., Boyle G.E., and Meaney J.F. Normal anterior spinal arteries within the cervical region: high-spatial-resolution contrast-enhanced three-dimensional MR angiography. Radiology 236 2 (2005 Aug) 637-641
    • (2005) Radiology , vol.236 , Issue.2 , pp. 637-641
    • Sheehy, N.P.1    Boyle, G.E.2    Meaney, J.F.3
  • 54
    • 28444450804 scopus 로고    scopus 로고
    • 3.0 T vs. 1.5 T MR angiography: in vitro comparison of intravascular stent artifacts
    • Wall A., Kugel H., Bachman R., Matuszewski L., Kramer S., Heindel W., et al. 3.0 T vs. 1.5 T MR angiography: in vitro comparison of intravascular stent artifacts. J Magn Reson Imaging 22 6 (2005 Dec) 772-779
    • (2005) J Magn Reson Imaging , vol.22 , Issue.6 , pp. 772-779
    • Wall, A.1    Kugel, H.2    Bachman, R.3    Matuszewski, L.4    Kramer, S.5    Heindel, W.6
  • 56
    • 0036594278 scopus 로고    scopus 로고
    • Value of 1.0 M gadolinium chelates: review of preclinical and clinical data on gadobutrol
    • Tombach B., and Heindel W. Value of 1.0 M gadolinium chelates: review of preclinical and clinical data on gadobutrol. Eur Radiol 12 (2002) 1550-1556
    • (2002) Eur Radiol , vol.12 , pp. 1550-1556
    • Tombach, B.1    Heindel, W.2
  • 57
    • 23844477876 scopus 로고    scopus 로고
    • MR angiography of aortoiliac occlusive disease: a phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325
    • Goyen M., Edelman M., Perreault P., O'Riordan E., Bertoni H., Taylor J., et al. MR angiography of aortoiliac occlusive disease: a phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325. Radiology 236 (2005) 825-833
    • (2005) Radiology , vol.236 , pp. 825-833
    • Goyen, M.1    Edelman, M.2    Perreault, P.3    O'Riordan, E.4    Bertoni, H.5    Taylor, J.6
  • 58
    • 33750011387 scopus 로고    scopus 로고
    • A summary of safety of gadofosveset (MS-325) at 0.03 mmol/kg body weight dose: phase II and phase III clinical trials data
    • Shamsi K., Yucel E.K., and Chamberlin P. A summary of safety of gadofosveset (MS-325) at 0.03 mmol/kg body weight dose: phase II and phase III clinical trials data. Invest Radiol 41 (2006) 822-830
    • (2006) Invest Radiol , vol.41 , pp. 822-830
    • Shamsi, K.1    Yucel, E.K.2    Chamberlin, P.3
  • 59
    • 0346656698 scopus 로고    scopus 로고
    • Gadobenate dimeglumine (MultiHance) for magnetic resonance angiography: review of the literature
    • Goyen M., and Debatin J.F. Gadobenate dimeglumine (MultiHance) for magnetic resonance angiography: review of the literature. Eur Radiol 13 Suppl. 3 (2003 Nov) N19-N27
    • (2003) Eur Radiol , vol.13 , Issue.SUPPL. 3
    • Goyen, M.1    Debatin, J.F.2
  • 60
    • 0141989915 scopus 로고    scopus 로고
    • Gadobenate dimeglumine (Gd-DTPA) vs gadopentetate dimeglumine (Gd-BOPTA) for contrast-enhanced magnetic resonance angiography (MRA): improvement in intravascular signal intensity and contrast to noise ratio
    • Pediconi F., Fraioli F., Catalano C., Napoli A., Danti M., Francone M., et al. Gadobenate dimeglumine (Gd-DTPA) vs gadopentetate dimeglumine (Gd-BOPTA) for contrast-enhanced magnetic resonance angiography (MRA): improvement in intravascular signal intensity and contrast to noise ratio. Radiol Med (Torino) 106 1-2 (2003 Jul-Aug) 87-93
    • (2003) Radiol Med (Torino) , vol.106 , Issue.1-2 , pp. 87-93
    • Pediconi, F.1    Fraioli, F.2    Catalano, C.3    Napoli, A.4    Danti, M.5    Francone, M.6
  • 61
    • 2942709854 scopus 로고    scopus 로고
    • MR angiography with sensitivity encoding (SENSE) for suspected pulmonary embolism: comparison with MDCT and ventilation-perfusion scintigraphy
    • Ohno Y., Higashino T., Takenaka D., Sugimoto K., Yoshikawa T., Kawai H., et al. MR angiography with sensitivity encoding (SENSE) for suspected pulmonary embolism: comparison with MDCT and ventilation-perfusion scintigraphy. Am J Roentgenol 183 (2004) 91-98
    • (2004) Am J Roentgenol , vol.183 , pp. 91-98
    • Ohno, Y.1    Higashino, T.2    Takenaka, D.3    Sugimoto, K.4    Yoshikawa, T.5    Kawai, H.6
  • 62
    • 33846217773 scopus 로고    scopus 로고
    • Acute pulmonary embolism to the subsegmental level: diagnostic accuracy of three MRI techniques compared with 16-MDCT
    • Kluge A., Luboldt W., and Bachmann G. Acute pulmonary embolism to the subsegmental level: diagnostic accuracy of three MRI techniques compared with 16-MDCT. Am J Roentgenol 187 1 (2006 Jul) W7-W14
    • (2006) Am J Roentgenol , vol.187 , Issue.1
    • Kluge, A.1    Luboldt, W.2    Bachmann, G.3
  • 64
    • 1642353675 scopus 로고    scopus 로고
    • Regional lung perfusion: assessment with partially parallel three-dimensional MR imaging
    • Fink C., Puderbach M., Bock M., Lodemann K.P., Zuna I., Schmahl A., et al. Regional lung perfusion: assessment with partially parallel three-dimensional MR imaging. Radiology 231 (2004) 175-184
    • (2004) Radiology , vol.231 , pp. 175-184
    • Fink, C.1    Puderbach, M.2    Bock, M.3    Lodemann, K.P.4    Zuna, I.5    Schmahl, A.6
  • 65
    • 33745496952 scopus 로고    scopus 로고
    • Experience in 207 combined MRI examinations for acute pulmonary embolism and deep vein thrombosis
    • Kluge A., Mueller C., Strunk J., Lange U., and Bachmann G. Experience in 207 combined MRI examinations for acute pulmonary embolism and deep vein thrombosis. Am J Roentgenol 186 6 (2006 Jun) 1686-1696
    • (2006) Am J Roentgenol , vol.186 , Issue.6 , pp. 1686-1696
    • Kluge, A.1    Mueller, C.2    Strunk, J.3    Lange, U.4    Bachmann, G.5
  • 66
    • 0242290982 scopus 로고    scopus 로고
    • Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: preliminary results in 12 patients
    • Aschauer M., Deutschmann H.A., Stollberger R., Hausegger K.A., Obernosterer A., Schollnast H., et al. Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: preliminary results in 12 patients. Magn Reson Med 50 (2003) 993-1002
    • (2003) Magn Reson Med , vol.50 , pp. 993-1002
    • Aschauer, M.1    Deutschmann, H.A.2    Stollberger, R.3    Hausegger, K.A.4    Obernosterer, A.5    Schollnast, H.6
  • 68
    • 0030656492 scopus 로고    scopus 로고
    • MR angiography of the supra-aortic arteries using a dedicated head and neck coil: image quality and assessment of stenoses
    • Fellner C., Strotzer M., Fraunhofer S., Held P., Spies V., Seitz J., et al. MR angiography of the supra-aortic arteries using a dedicated head and neck coil: image quality and assessment of stenoses. Neuroradiology 39 (1997) 763-771
    • (1997) Neuroradiology , vol.39 , pp. 763-771
    • Fellner, C.1    Strotzer, M.2    Fraunhofer, S.3    Held, P.4    Spies, V.5    Seitz, J.6
  • 69
    • 0034976061 scopus 로고    scopus 로고
    • Contrast-enhanced magnetic resonance angiography of the carotid bifurcation using the time-resolved imaging of contrast kinetics (TRICKS) technique
    • Turski P.A., Korosec F.R., Carroll T.J., Willig D.S., Grist T.M., and Mistretta C.A. Contrast-enhanced magnetic resonance angiography of the carotid bifurcation using the time-resolved imaging of contrast kinetics (TRICKS) technique. Top Magn Reson Imaging 12 (2001) 175-181
    • (2001) Top Magn Reson Imaging , vol.12 , pp. 175-181
    • Turski, P.A.1    Korosec, F.R.2    Carroll, T.J.3    Willig, D.S.4    Grist, T.M.5    Mistretta, C.A.6
  • 70
    • 0038304334 scopus 로고    scopus 로고
    • Duplex ultrasound and magnetic resonance angiography compared with digital subtraction angiography in carotid artery stenosis: a systematic review
    • Nederkoorn P.J., van der Graaf Y., and Hunink M.G. Duplex ultrasound and magnetic resonance angiography compared with digital subtraction angiography in carotid artery stenosis: a systematic review. Stroke 34 (2003) 1324-1332
    • (2003) Stroke , vol.34 , pp. 1324-1332
    • Nederkoorn, P.J.1    van der Graaf, Y.2    Hunink, M.G.3
  • 71
    • 0031001799 scopus 로고    scopus 로고
    • Intracranial aneurysms: detection and characterization with MR angiography with use of an advanced post-processing technique in a blinded-reader study
    • Atlas S.W., Sheppard L., Goldberg H.I., Hurst R.W., Listerud J., and Flamm E. Intracranial aneurysms: detection and characterization with MR angiography with use of an advanced post-processing technique in a blinded-reader study. Radiology 203 (1997) 807-814
    • (1997) Radiology , vol.203 , pp. 807-814
    • Atlas, S.W.1    Sheppard, L.2    Goldberg, H.I.3    Hurst, R.W.4    Listerud, J.5    Flamm, E.6
  • 72
    • 0036887212 scopus 로고    scopus 로고
    • Cerebral arteriovenous malformations: morphologic evaluation by ultrashort 3D gadolinium-enhanced MR angiography
    • Duran M., Schoenberg S.O., Yuh W.T., Knopp M.V., van Kaick G., and Essig M. Cerebral arteriovenous malformations: morphologic evaluation by ultrashort 3D gadolinium-enhanced MR angiography. Eur Radiol 12 (2002) 2957-2964
    • (2002) Eur Radiol , vol.12 , pp. 2957-2964
    • Duran, M.1    Schoenberg, S.O.2    Yuh, W.T.3    Knopp, M.V.4    van Kaick, G.5    Essig, M.6
  • 74
    • 7244251945 scopus 로고    scopus 로고
    • Craniocervical artery dissection: diagnosis and follow-up with MR imaging and MR angiography
    • Gelal F.M., Kitis O., Calli C., Yunten N., Vidinli B.D., and Uygur M. Craniocervical artery dissection: diagnosis and follow-up with MR imaging and MR angiography. Med Sci Monit 10 (2004) MT109-MT116
    • (2004) Med Sci Monit , vol.10
    • Gelal, F.M.1    Kitis, O.2    Calli, C.3    Yunten, N.4    Vidinli, B.D.5    Uygur, M.6
  • 76
    • 33750333943 scopus 로고    scopus 로고
    • Vessel wall calcifications at multi-detector row CT angiography in patients with peripheral arterial disease: effect on clinical utility and clinical predictors
    • Ouwendijk R., Kock M.C., van Dijk L.C., van Sambeek M.R., Stijnen T., and Hunink M.G. Vessel wall calcifications at multi-detector row CT angiography in patients with peripheral arterial disease: effect on clinical utility and clinical predictors. Radiology 241 (2006) 603-608
    • (2006) Radiology , vol.241 , pp. 603-608
    • Ouwendijk, R.1    Kock, M.C.2    van Dijk, L.C.3    van Sambeek, M.R.4    Stijnen, T.5    Hunink, M.G.6
  • 77
    • 33644841422 scopus 로고    scopus 로고
    • Interobserver agreement for the interpretation of contrast-enhanced 3D MR angiography and MDCT in peripheral arterial disease
    • Ouwendijk R., Kock M.C., Visser K., Pattynama P.M.T., de Haan M.W., and Hunink M.G. Interobserver agreement for the interpretation of contrast-enhanced 3D MR angiography and MDCT in peripheral arterial disease. AJR Am J Roentgenol 185 (2005) 1261-1276
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 1261-1276
    • Ouwendijk, R.1    Kock, M.C.2    Visser, K.3    Pattynama, P.M.T.4    de Haan, M.W.5    Hunink, M.G.6
  • 78
    • 0031838059 scopus 로고    scopus 로고
    • MR angiography of the aortoiliac and femoropopliteal vessels
    • Rofsky N.M. MR angiography of the aortoiliac and femoropopliteal vessels. Magn Reson Imaging Clin N Am 6 2 (1998 May) 371-384
    • (1998) Magn Reson Imaging Clin N Am , vol.6 , Issue.2 , pp. 371-384
    • Rofsky, N.M.1
  • 79
    • 0031931632 scopus 로고    scopus 로고
    • Gadolinium-enhanced MR angiography of extra-anatomic arterial bypass grafts
    • Krinsky G., Jacobowitz G., and Rofsky N. Gadolinium-enhanced MR angiography of extra-anatomic arterial bypass grafts. Am J Roentgenol 170 3 (1998) 735-741
    • (1998) Am J Roentgenol , vol.170 , Issue.3 , pp. 735-741
    • Krinsky, G.1    Jacobowitz, G.2    Rofsky, N.3
  • 80
    • 0030868123 scopus 로고    scopus 로고
    • Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography
    • Rofsky N.M., Johnson G., Adelman M.A., Rosen R.J., Krinsky G.A., and Weinreb J.C. Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography. Radiology 205 1 (1997 Oct) 163-169
    • (1997) Radiology , vol.205 , Issue.1 , pp. 163-169
    • Rofsky, N.M.1    Johnson, G.2    Adelman, M.A.3    Rosen, R.J.4    Krinsky, G.A.5    Weinreb, J.C.6
  • 82
    • 0035090141 scopus 로고    scopus 로고
    • Contrast-enhanced peripheral MR angiography from the abdominal aorta to the pedal arteries: combined dynamic two-dimensional and bolus-chase three-dimensional acquisitions
    • Wang Y., Winchester P.A., Khilnani N.M., Lee H.M., Watts R., Trost D.W., et al. Contrast-enhanced peripheral MR angiography from the abdominal aorta to the pedal arteries: combined dynamic two-dimensional and bolus-chase three-dimensional acquisitions. Invest Radiol 36 3 (2001 Mar) 170-177
    • (2001) Invest Radiol , vol.36 , Issue.3 , pp. 170-177
    • Wang, Y.1    Winchester, P.A.2    Khilnani, N.M.3    Lee, H.M.4    Watts, R.5    Trost, D.W.6
  • 83
    • 0036089459 scopus 로고    scopus 로고
    • Peripheral vascular disease: combined 3D bolus chase and dynamic 2D MR angiography compared with X-ray angiography for treatment planning
    • Khilnani N.M., Winchester P.A., Prince M.R., Vidan E., Trost D.W., Bush Jr. H.L., et al. Peripheral vascular disease: combined 3D bolus chase and dynamic 2D MR angiography compared with X-ray angiography for treatment planning. Radiology 224 1 (2002 Jul) 63-74
    • (2002) Radiology , vol.224 , Issue.1 , pp. 63-74
    • Khilnani, N.M.1    Winchester, P.A.2    Prince, M.R.3    Vidan, E.4    Trost, D.W.5    Bush Jr., H.L.6
  • 85
    • 33847147517 scopus 로고    scopus 로고
    • Clinical utility of time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance angiography for infrageniculate arterial occlusive disease
    • Mell M., Tefera G., Thornton F., Siepman D., and Turnipseed W. Clinical utility of time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance angiography for infrageniculate arterial occlusive disease. J Vasc Surg 45 3 (2007 Mar) 543-548
    • (2007) J Vasc Surg , vol.45 , Issue.3 , pp. 543-548
    • Mell, M.1    Tefera, G.2    Thornton, F.3    Siepman, D.4    Turnipseed, W.5
  • 86
    • 33746884629 scopus 로고    scopus 로고
    • High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging
    • Thornton F.J., Du J., Suleiman S.A., Dieter R., Tefera G., Pillai K.R., et al. High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging. J Magn Reson Imaging 24 2 (2006 Aug) 362-370
    • (2006) J Magn Reson Imaging , vol.24 , Issue.2 , pp. 362-370
    • Thornton, F.J.1    Du, J.2    Suleiman, S.A.3    Dieter, R.4    Tefera, G.5    Pillai, K.R.6
  • 87
    • 0032876353 scopus 로고    scopus 로고
    • Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress
    • Ho V.B., Choyke P.L., Foo T.K., Hood M.N., Miller D.L., Czum J.M., et al. Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress. J Magn Reson Imaging 10 3 (1999 Sep) 376-388
    • (1999) J Magn Reson Imaging , vol.10 , Issue.3 , pp. 376-388
    • Ho, V.B.1    Choyke, P.L.2    Foo, T.K.3    Hood, M.N.4    Miller, D.L.5    Czum, J.M.6
  • 88
    • 0036067821 scopus 로고    scopus 로고
    • Bolus arterial-venous transit in the lower extremity and venous contamination in bolus chase three-dimensional magnetic resonance angiography
    • Wang Y., Chen C.Z., Chabra S.G., Winchester P.A., Khilnani N.M., Watts R., et al. Bolus arterial-venous transit in the lower extremity and venous contamination in bolus chase three-dimensional magnetic resonance angiography. Invest Radiol 37 8 (2002 Aug) 458-463
    • (2002) Invest Radiol , vol.37 , Issue.8 , pp. 458-463
    • Wang, Y.1    Chen, C.Z.2    Chabra, S.G.3    Winchester, P.A.4    Khilnani, N.M.5    Watts, R.6
  • 89
    • 0036088441 scopus 로고    scopus 로고
    • Contrast material travel times in patients undergoing peripheral MR angiography
    • Prince M.R., Chabra S.G., Watts R., Chen C.Z., Winchester P.A., Khilnani N.M., et al. Contrast material travel times in patients undergoing peripheral MR angiography. Radiology 224 1 (2002 Jul) 55-61
    • (2002) Radiology , vol.224 , Issue.1 , pp. 55-61
    • Prince, M.R.1    Chabra, S.G.2    Watts, R.3    Chen, C.Z.4    Winchester, P.A.5    Khilnani, N.M.6
  • 90
    • 7944223406 scopus 로고    scopus 로고
    • Decreased venous contamination on 3D gadolinium-enhanced bolus chase peripheral MR angiography using thigh compression
    • Zhang H.L., Ho B.Y., Chao M., Kent K.C., Bush H.L., Faries P.L., et al. Decreased venous contamination on 3D gadolinium-enhanced bolus chase peripheral MR angiography using thigh compression. Am J Roentgenol 183 4 (2004 Oct) 1041-1047
    • (2004) Am J Roentgenol , vol.183 , Issue.4 , pp. 1041-1047
    • Zhang, H.L.1    Ho, B.Y.2    Chao, M.3    Kent, K.C.4    Bush, H.L.5    Faries, P.L.6
  • 91
    • 0037417499 scopus 로고    scopus 로고
    • High-resolution magnetic resonance angiography of hands with timed arterial compression (tac-MRA)
    • Wentz K.U., Frohlich J.M., von Weymarn C., Patak M.A., Jenelten R., and Zollikofer C.L. High-resolution magnetic resonance angiography of hands with timed arterial compression (tac-MRA). Lancet 361 9351 (2003 Jan 4) 49-50
    • (2003) Lancet , vol.361 , Issue.9351 , pp. 49-50
    • Wentz, K.U.1    Frohlich, J.M.2    von Weymarn, C.3    Patak, M.A.4    Jenelten, R.5    Zollikofer, C.L.6
  • 92
    • 0035820272 scopus 로고    scopus 로고
    • Rapid magnetic resonance angiography for detection of atherosclerosis
    • Ruehm S.G., Goyen M., Barkhausen J., Kroger K., Bosk S., Ladd M.E., et al. Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 357 9262 (2001 Apr 7) 1086-1091
    • (2001) Lancet , vol.357 , Issue.9262 , pp. 1086-1091
    • Ruehm, S.G.1    Goyen, M.2    Barkhausen, J.3    Kroger, K.4    Bosk, S.5    Ladd, M.E.6
  • 93
    • 33746629861 scopus 로고    scopus 로고
    • Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease
    • Epub 2005 Sep 21
    • Goyen M., Herborn C.U., Kroger K., Ruehm S.G., and Debatin J.F. Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease. Eur Radiol 16 3 (2006 Mar) 685-691 Epub 2005 Sep 21
    • (2006) Eur Radiol , vol.16 , Issue.3 , pp. 685-691
    • Goyen, M.1    Herborn, C.U.2    Kroger, K.3    Ruehm, S.G.4    Debatin, J.F.5
  • 94
    • 33846560204 scopus 로고    scopus 로고
    • Multistation whole-body high-spatial-resolution MR angiography using a 32-channel MR system
    • Nael K., Ruehm S.G., Michaely H.J., Saleh R., Lee M., Laub G., et al. Multistation whole-body high-spatial-resolution MR angiography using a 32-channel MR system. Am J Roentgenol 188 2 (2007 Feb) 529-539
    • (2007) Am J Roentgenol , vol.188 , Issue.2 , pp. 529-539
    • Nael, K.1    Ruehm, S.G.2    Michaely, H.J.3    Saleh, R.4    Lee, M.5    Laub, G.6
  • 95
    • 27544442176 scopus 로고    scopus 로고
    • Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    • Rohrer M., Bauer H., Mintorovitch J., Requardt M., and Weinmann H.J. Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40 (2005) 715-724
    • (2005) Invest Radiol , vol.40 , pp. 715-724
    • Rohrer, M.1    Bauer, H.2    Mintorovitch, J.3    Requardt, M.4    Weinmann, H.J.5
  • 96
    • 33745931761 scopus 로고    scopus 로고
    • Initial imaging recommendations for Vasovist angiography
    • Hartmann M., Wiethoff A.J., Hentrich H.R., and Rohrer M. Initial imaging recommendations for Vasovist angiography. Eur Radiol 16 Suppl. 2 (2006) B15-B23
    • (2006) Eur Radiol , vol.16 , Issue.SUPPL. 2
    • Hartmann, M.1    Wiethoff, A.J.2    Hentrich, H.R.3    Rohrer, M.4
  • 98
    • 0038122922 scopus 로고    scopus 로고
    • 3DVIEWNIX-AVS: a software package for the separate visualization of arteries and veins in CE-MRA images
    • Lei T., Udupa J.K., Odhner D., Nyúl L.G., and Saha P.K. 3DVIEWNIX-AVS: a software package for the separate visualization of arteries and veins in CE-MRA images. Comput Med Imaging Graph 27 (2003) 351-362
    • (2003) Comput Med Imaging Graph , vol.27 , pp. 351-362
    • Lei, T.1    Udupa, J.K.2    Odhner, D.3    Nyúl, L.G.4    Saha, P.K.5
  • 99
    • 33846541879 scopus 로고    scopus 로고
    • Gadodiamide-associated nephrogenic systemic fibrosis: why radiologists should be concerned
    • Broome D.R., Girguis M.S., Baron P.W., Cottrell A.C., Kjellin I., and Kirk G.A. Gadodiamide-associated nephrogenic systemic fibrosis: why radiologists should be concerned. Am J Roentgenol 188 (2007) 586-592
    • (2007) Am J Roentgenol , vol.188 , pp. 586-592
    • Broome, D.R.1    Girguis, M.S.2    Baron, P.W.3    Cottrell, A.C.4    Kjellin, I.5    Kirk, G.A.6
  • 100
    • 29544443426 scopus 로고    scopus 로고
    • MR angiography at 3 T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils
    • Majoie C.B., Sprengers M.E., van Rooij W.J., Lavini C., Sluzewski M., van Rijn J.C., et al. MR angiography at 3 T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils. AJNR Am J Neuroradiol 26 6 (2005 Jun-Jul) 1349-1356
    • (2005) AJNR Am J Neuroradiol , vol.26 , Issue.6 , pp. 1349-1356
    • Majoie, C.B.1    Sprengers, M.E.2    van Rooij, W.J.3    Lavini, C.4    Sluzewski, M.5    van Rijn, J.C.6
  • 101
    • 33746916752 scopus 로고    scopus 로고
    • High resolution 3 T MRI for the assessment of cervical and superficial cranial arteries in giant cell arteritis
    • Markl M., Uhl M., Wieben O., Ness T., Langer M., Hennig J., et al. High resolution 3 T MRI for the assessment of cervical and superficial cranial arteries in giant cell arteritis. J Magn Reson Imaging 24 2 (2006 Aug) 423-427
    • (2006) J Magn Reson Imaging , vol.24 , Issue.2 , pp. 423-427
    • Markl, M.1    Uhl, M.2    Wieben, O.3    Ness, T.4    Langer, M.5    Hennig, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.