메뉴 건너뛰기




Volumn 15, Issue 3, 2004, Pages 169-185

Parallel imaging in MR angiography

Author keywords

Magnetic resonance angiography (MRA); Magnetic resonance imaging (MRI); Parallel imaging; SENSE; SMASH

Indexed keywords

ABDOMEN CONTRAST ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY; ARTIFACT REDUCTION; BOLUS INJECTION; BRAIN ANGIOGRAPHY; BREATH HOLDING; CAROTID ARTERY; CONTRAST ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY; CONTRAST ENHANCEMENT; FLOW MEASUREMENT; HEMODYNAMICS; HUMAN; IMAGING; INFLOW CONTRAST IMAGING; KIDNEY ANGIOGRAPHY; KIDNEY CONTRAST ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY; MAGNETIC RESONANCE ANGIOGRAPHY; NEURO PHASE CONTRAST VENOGRAPHY; NEURO PHASE CONTRAST WHOLE BRAIN ANGIOGRAPHY; NUCLEAR MAGNETIC RESONANCE IMAGING; OPTICAL RESOLUTION; PARALLEL IMAGING; PEDIATRICS; PERIPHERAL CONTRAST ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY; PERIPHERAL VASCULAR DISEASE; PHASE CONTRAST IMAGING; PHLEBOGRAPHY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REAL TIME QUANTITATIVE FLOW; REVIEW; SENSITIVITY ENCODING; SIGNAL NOISE RATIO; SIMULTANEOUS ACQUISITION OF SPATIAL HARMONICS; SPATIAL RESOLUTION; TECHNIQUE; TEMPORAL RESOLUTION; THORAX; THORAX CONTRAST ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY; TIME; TIME RESOLVED CONTRAST ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY;

EID: 4444254096     PISSN: 08993459     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rmr.0000134199.94874.70     Document Type: Review
Times cited : (56)

References (127)
  • 1
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson D, Manning W. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med. 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.1    Manning, W.2
  • 2
    • 0032425458 scopus 로고    scopus 로고
    • AUTO-SMASH: A self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics
    • Jakob P, et al. AUTO-SMASH: a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics. MAGMA. 1998;7:42-54.
    • (1998) MAGMA , vol.7 , pp. 42-54
    • Jakob, P.1
  • 3
    • 0033854213 scopus 로고    scopus 로고
    • Senstivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
    • Kyriakos W, et al. Senstivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP). Magn Reson Med. 2000;44: 301-308.
    • (2000) Magn Reson Med , vol.44 , pp. 301-308
    • Kyriakos, W.1
  • 4
    • 0034997208 scopus 로고    scopus 로고
    • VD-AUTO-SMASH imaging
    • Heidemann R, et al. VD-AUTO-SMASH imaging. Magn Reson Med. 2001;45:1066-1074.
    • (2001) Magn Reson Med , vol.45 , pp. 1066-1074
    • Heidemann, R.1
  • 5
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold M, et al, Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.1
  • 6
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • Pruessmann K, et al. SENSE: Sensitivity encoding for fast MRI. Magn Reson Med. 1999;42:952-962.
    • (1999) Magn Reson Med , vol.42 , pp. 952-962
    • Pruessmann, K.1
  • 7
    • 0035006567 scopus 로고    scopus 로고
    • SMASH and SENSE: Experimental and numerical comparisons
    • Madore B, Pelc N. SMASH and SENSE: experimental and numerical comparisons, Magn Reson Med. 2001;45:1103-1111.
    • (2001) Magn Reson Med , vol.45 , pp. 1103-1111
    • Madore, B.1    Pelc, N.2
  • 8
    • 0033772492 scopus 로고    scopus 로고
    • Partially parallel imaging with localized sensitivities (PILS)
    • Griswold M, et al. Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med. 2000;44:602-609.
    • (2000) Magn Reson Med , vol.44 , pp. 602-609
    • Griswold, M.1
  • 9
    • 0025226022 scopus 로고
    • The NMR phased array
    • Roemer P, et al, The NMR phased array. Magn Reson Med. 1990;16: 192-225.
    • (1990) Magn Reson Med , vol.16 , pp. 192-225
    • Roemer, P.1
  • 10
    • 4444220410 scopus 로고    scopus 로고
    • US Patent 6326786, in USPTO. United States Patent Office, 2001
    • Pruessmann K, et al, US Patent 6326786, in USPTO. United States Patent Office, 2001.
    • Pruessmann, K.1
  • 11
    • 10744225741 scopus 로고    scopus 로고
    • Implications of SENSE MR in routine clinical practice
    • van den Brink J, et al. Implications of SENSE MR in routine clinical practice. Eur J Radiol. 2003;46:3-27.
    • (2003) Eur J Radiol , vol.46 , pp. 3-27
    • Van Den Brink, J.1
  • 13
    • 0036188010 scopus 로고    scopus 로고
    • Self-calibrating parallel imaging with automatic coil sensitivity extraction
    • McKenzie C, et al. Self-calibrating parallel imaging with automatic coil sensitivity extraction. Magn Reson Med. 2002;47:529-538.
    • (2002) Magn Reson Med , vol.47 , pp. 529-538
    • McKenzie, C.1
  • 14
    • 0345016340 scopus 로고    scopus 로고
    • Auto-SENSE perfusion imaging of the whole human heart
    • Kostler H, et al. Auto-SENSE perfusion imaging of the whole human heart. J Magn Reson Imaging. 2003;18:702-708.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 702-708
    • Kostler, H.1
  • 15
    • 0036105436 scopus 로고    scopus 로고
    • Coil sensitivity encoding in MR imaging: Advantages and disadvantages in clinical practice
    • Kurihara Y, et al. Coil sensitivity encoding in MR imaging: advantages and disadvantages in clinical practice. AJR Am J Roentgenol. 2002;178: 1087-1091.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1087-1091
    • Kurihara, Y.1
  • 16
    • 0033760130 scopus 로고    scopus 로고
    • Contrast-enhanced 3d MRA using SENSE
    • Weiger M, et al. Contrast-enhanced 3d MRA using SENSE. J Magn Reson Imaging. 2000;12:671-677.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 671-677
    • Weiger, M.1
  • 17
    • 0032997647 scopus 로고    scopus 로고
    • Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH)
    • Griswold M, et al. Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH). Magn Reson Med. 1999;41:1236-1245.
    • (1999) Magn Reson Med , vol.41 , pp. 1236-1245
    • Griswold, M.1
  • 18
    • 0034850918 scopus 로고    scopus 로고
    • Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE)
    • Bammer R, et al. Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med. 2001;46:548-554.
    • (2001) Magn Reson Med , vol.46 , pp. 548-554
    • Bammer, R.1
  • 19
    • 4444376747 scopus 로고    scopus 로고
    • High-resolution MR-angiography of the renal angiography of the renal arteries using Integrated parallel Acquisition Techniques (iPAT) with an Auto-SMASH-Algorithm
    • Schoenberg S, et al. High-resolution MR-angiography of the renal angiography of the renal arteries using Integrated parallel Acquisition Techniques (iPAT) with an Auto-SMASH-Algorithm. Proc Intl Soc Magn Reson Med. 2003;11:327.
    • (2003) Proc Intl Soc Magn Reson Med , vol.11 , pp. 327
    • Schoenberg, S.1
  • 20
    • 0034538104 scopus 로고    scopus 로고
    • Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: A pilot study
    • Sodickson D, et al. Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: a pilot study. Radiology. 2000; 217:284-289.
    • (2000) Radiology , vol.217 , pp. 284-289
    • Sodickson, D.1
  • 21
    • 0028351567 scopus 로고
    • Gadolinium-enhanced MR aortography
    • Prince M. Gadolinium-enhanced MR aortography. Radiology. 1994; 191:155-164.
    • (1994) Radiology , vol.191 , pp. 155-164
    • Prince, M.1
  • 22
    • 0029763248 scopus 로고    scopus 로고
    • Improved centric phase encoding orders for three-dimensional magnetization-prepared MR angiography
    • Wilman A, Riederer S. Improved centric phase encoding orders for three-dimensional magnetization-prepared MR angiography. Magn Reson Med. 1996;36:384-392.
    • (1996) Magn Reson Med , vol.36 , pp. 384-392
    • Wilman, A.1    Riederer, S.2
  • 23
    • 0036829410 scopus 로고    scopus 로고
    • Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: Initial experience
    • Willinek W, et al. Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology. 2002;225:583-588.
    • (2002) Radiology , vol.225 , pp. 583-588
    • Willinek, W.1
  • 24
    • 0029758290 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced 3D MR angiography
    • Korosec F, et al. Time-resolved contrast-enhanced 3D MR angiography. Magn Reson Med. 1996;36:345-351.
    • (1996) Magn Reson Med , vol.36 , pp. 345-351
    • Korosec, F.1
  • 25
    • 0032967860 scopus 로고    scopus 로고
    • Renal arteries: Optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold
    • Schoenberg S, et al. Renal arteries: optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold. Radiology. 1999;211: 667-679.
    • (1999) Radiology , vol.211 , pp. 667-679
    • Schoenberg, S.1
  • 26
    • 0030770299 scopus 로고    scopus 로고
    • Fluoroscopically-triggered contrast-enhanced three dimensional MR angiography with elliptical centric view order: Application to the renal arteries
    • Wilman A, et al. Fluoroscopically-triggered contrast-enhanced three dimensional MR angiography with elliptical centric view order: application to the renal arteries. Radiology. 1997;205:137-146.
    • (1997) Radiology , vol.205 , pp. 137-146
    • Wilman, A.1
  • 27
    • 0032471753 scopus 로고    scopus 로고
    • Optimizing three-dimensional gadolinium-enhanced MR angiography
    • Maki J, Chenevert T, Prince M. Optimizing three-dimensional gadolinium-enhanced MR angiography. Invest Radiol. 1998;33:528-537.
    • (1998) Invest Radiol , vol.33 , pp. 528-537
    • Maki, J.1    Chenevert, T.2    Prince, M.3
  • 28
    • 0031403821 scopus 로고    scopus 로고
    • The effects of incomplete breath holding on 3D MR image quality
    • Maki J, Chenevert T, Prince M. The effects of incomplete breath holding on 3D MR image quality. J Magn Reson Imaging. 1997;7:1132-1139.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 1132-1139
    • Maki, J.1    Chenevert, T.2    Prince, M.3
  • 29
    • 0034758970 scopus 로고    scopus 로고
    • Optimization of view ordering for motion artifact suppression
    • Nguyen T, et al. Optimization of view ordering for motion artifact suppression. Magn Reson Imaging. 2001;19:951-957.
    • (2001) Magn Reson Imaging , vol.19 , pp. 951-957
    • Nguyen, T.1
  • 30
    • 0030705199 scopus 로고    scopus 로고
    • Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breathhold three-dimensional gradient echo imaging
    • Wilman A, Riederer S. Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breathhold three-dimensional gradient echo imaging. Magn Reson Med. 1997;38: 793-802.
    • (1997) Magn Reson Med , vol.38 , pp. 793-802
    • Wilman, A.1    Riederer, S.2
  • 31
    • 0035001621 scopus 로고    scopus 로고
    • Dependence of venous enhancement on the field of view in 3D contrast-enhanced MRA using the elliptical centric view order
    • Fain S, Riederer S. Dependence of venous enhancement on the field of view in 3D contrast-enhanced MRA using the elliptical centric view order. Magn Reson Med. 2001;45:1134-1141.
    • (2001) Magn Reson Med , vol.45 , pp. 1134-1141
    • Fain, S.1    Riederer, S.2
  • 32
    • 0035140372 scopus 로고    scopus 로고
    • High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography
    • Fain S, et al. High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: a prospective comparison with digital subtraction angiography. Radiology. 2001;218:481-490.
    • (2001) Radiology , vol.218 , pp. 481-490
    • Fain, S.1
  • 33
    • 0032758576 scopus 로고    scopus 로고
    • Theoretical limits of spatial resolution in elliptical-centric contrast-enhanced 3d-MRA
    • Fain S, et al. Theoretical limits of spatial resolution in elliptical-centric contrast-enhanced 3d-MRA. Magn Reson Med. 1999;42:1106-1116.
    • (1999) Magn Reson Med , vol.42 , pp. 1106-1116
    • Fain, S.1
  • 34
    • 0030183445 scopus 로고    scopus 로고
    • The effects of time varying intravascular signal intensity on three-dimensional MR angiography image quality
    • Maki J, et al. The effects of time varying intravascular signal intensity on three-dimensional MR angiography image quality. J Magn Reson Imaging. 1996;6:642-651.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 642-651
    • Maki, J.1
  • 36
    • 0036200239 scopus 로고    scopus 로고
    • Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography
    • Maki J, et al. Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography. J Magn Reson Imaging. 2002;15:484-491.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 484-491
    • Maki, J.1
  • 38
    • 0038640469 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced magnetic resonance angiography in pediatric patients using sensitivity encoding
    • Muthupillai R, et al. Time-resolved contrast-enhanced magnetic resonance angiography in pediatric patients using sensitivity encoding. J Magn Reson Imaging. 2003;17:559-564.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 559-564
    • Muthupillai, R.1
  • 39
    • 0034821090 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE)
    • Golay X, et al. Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE). AJNR Am JNeuroradiol. 2001; 22:1615-1619.
    • (2001) AJNR Am JNeuroradiol , vol.22 , pp. 1615-1619
    • Golay, X.1
  • 40
    • 0037369916 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE)
    • Ohno Y, et al. Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE). J Magn Reson Imaging. 2003;17:330-336.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 330-336
    • Ohno, Y.1
  • 42
    • 4444298721 scopus 로고    scopus 로고
    • Direct comparison of sensitivity encoding (SENSE) accelerated and conventional 3D contrast enhanced mr angiography (CE-MRA) of renal arteries: Effect of increased spatial resolution
    • Kyoto, Japan
    • Douglas E, et al. Direct comparison of sensitivity encoding (SENSE) accelerated and conventional 3D contrast enhanced mr angiography (CE-MRA) of renal arteries: effect of increased spatial resolution. In: Proceedings of Section for Magnetic Resonance Technologists (SMRT), Kyoto, Japan. 2004.
    • (2004) Proceedings of Section for Magnetic Resonance Technologists (SMRT)
    • Douglas, E.1
  • 43
    • 0141783642 scopus 로고    scopus 로고
    • High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE)
    • Walter C, et al. High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE). Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2003;175:1244-1250.
    • (2003) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.175 , pp. 1244-1250
    • Walter, C.1
  • 44
    • 0345015505 scopus 로고    scopus 로고
    • 3.0T time-of-flight MR angiography: Comparison with 1.5T. Initial experience
    • Willinek W, et al. 3.0T time-of-flight MR angiography: comparison with 1.5T. Initial experience. Radiology. 2003;229:913-920.
    • (2003) Radiology , vol.229 , pp. 913-920
    • Willinek, W.1
  • 45
    • 0034001013 scopus 로고    scopus 로고
    • Accuracy of normal-dose contrast-enhanced MR angiography in assessing renal artery stenosis and accessory renal arteries
    • Korst M, et al. Accuracy of normal-dose contrast-enhanced MR angiography in assessing renal artery stenosis and accessory renal arteries. AJR Am J Roentgenol. 2000;174:629-634
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 629-634
    • Korst, M.1
  • 46
    • 0012465976 scopus 로고    scopus 로고
    • Renal artery stenosis: Evaluation with breathhold, three-dimensional, dynamic, gadolinium-enhanced versus phase contrast MR angiography with a phased array multicoil
    • De Cobelli F, et al. Renal artery stenosis: evaluation with breathhold, three-dimensional, dynamic, gadolinium-enhanced versus phase contrast MR angiography with a phased array multicoil. Radiology. 1997; 201:697-703.
    • (1997) Radiology , vol.201 , pp. 697-703
    • De Cobelli, F.1
  • 47
    • 0030805663 scopus 로고    scopus 로고
    • Evaluation of renal artery stenosis with dynamic gadolinium-enhanced MR angiography
    • Reiumont M, et al. Evaluation of renal artery stenosis with dynamic gadolinium-enhanced MR angiography. AJR Am J Roentgenol. 1997;169: 39-44.
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 39-44
    • Reiumont, M.1
  • 48
    • 0031421965 scopus 로고    scopus 로고
    • Contrast-enhanced, k-space-centered, breathhold MR angiography of the renal arteries and the abdominal aorta
    • Steffens J, et al. Contrast-enhanced, k-space-centered, breathhold MR angiography of the renal arteries and the abdominal aorta. J Magn Reson Imaging. 1997;7:617-622.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 617-622
    • Steffens, J.1
  • 49
    • 0031862272 scopus 로고    scopus 로고
    • Renal artery stenosis and accessory renal arteries: Accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography
    • Bakker J, et al. Renal artery stenosis and accessory renal arteries: accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography. Radiology. 1998;207:497-504.
    • (1998) Radiology , vol.207 , pp. 497-504
    • Bakker, J.1
  • 50
    • 0033652806 scopus 로고    scopus 로고
    • Motion of the proximal renal artery during the cardiac cycle
    • Kaandorp D, et al. Motion of the proximal renal artery during the cardiac cycle. J Magn Reson Imaging. 2000;12:924-928.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 924-928
    • Kaandorp, D.1
  • 51
    • 0036890799 scopus 로고    scopus 로고
    • Motion of the distal renal artery during 3D contrast-enhanced breathhold MRA
    • Vasbinder G, et al. Motion of the distal renal artery during 3D contrast-enhanced breathhold MRA. J Magn Reson Imaging. 2002;16:685-696.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 685-696
    • Vasbinder, G.1
  • 52
    • 0031784731 scopus 로고    scopus 로고
    • Limits to the accuracy of vessel diameter measurement in MR angiography
    • Hoogeveen R, Bakker C, Viergever M. Limits to the accuracy of vessel diameter measurement in MR angiography. J Magn Reson Imaging. 1998;8:1228-1235.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1228-1235
    • Hoogeveen, R.1    Bakker, C.2    Viergever, M.3
  • 54
    • 0035909055 scopus 로고    scopus 로고
    • Diagnostic tests for renal artery stenosis in patients suspected of having renovascular hypertension: A meta-analysis
    • Vasbinder G, et al. Diagnostic tests for renal artery stenosis in patients suspected of having renovascular hypertension: a meta-analysis. Ann Intern Med. 2001;135:401-411.
    • (2001) Ann Intern Med , vol.135 , pp. 401-411
    • Vasbinder, G.1
  • 55
    • 0031826638 scopus 로고    scopus 로고
    • Renal MR angiography
    • Dong Q, et al. Renal MR angiography. Semin Interv Radiol. 1998;15: 163-177.
    • (1998) Semin Interv Radiol , vol.15 , pp. 163-177
    • Dong, Q.1
  • 56
    • 0019364465 scopus 로고
    • Complications of angiography
    • Hessel S, Adams D, Abrams H. Complications of angiography. Radiology. 1981;138:273-281.
    • (1981) Radiology , vol.138 , pp. 273-281
    • Hessel, S.1    Adams, D.2    Abrams, H.3
  • 57
    • 0018965394 scopus 로고
    • Adverse reactions to contrast media: A report from the Committee on Safety of Contrast Media of the International Society of Radiology
    • Shehadi W, Toniolo G. Adverse reactions to contrast media: a report from the Committee on Safety of Contrast Media of the International Society of Radiology. Radiology. 1980;137:299-302.
    • (1980) Radiology , vol.137 , pp. 299-302
    • Shehadi, W.1    Toniolo, G.2
  • 58
    • 0031873828 scopus 로고    scopus 로고
    • Magnetic resonance angiography of lower-extremity arterial disease
    • Velazquez O, Baum R, Carpenter J. Magnetic resonance angiography of lower-extremity arterial disease. Surg Clin North Am. 1998;78:519-537.
    • (1998) Surg Clin North Am , vol.78 , pp. 519-537
    • Velazquez, O.1    Baum, R.2    Carpenter, J.3
  • 59
    • 0032930455 scopus 로고    scopus 로고
    • Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: Preliminary experience
    • Meaney J, et al. Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience. Radiology. 1999;211:59-67.
    • (1999) Radiology , vol.211 , pp. 59-67
    • Meaney, J.1
  • 60
    • 0031908601 scopus 로고    scopus 로고
    • Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography
    • Ho K, et al. Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography. Radiology. 1998;206:683-692.
    • (1998) Radiology , vol.206 , pp. 683-692
    • Ho, K.1
  • 61
    • 0032876353 scopus 로고    scopus 로고
    • Automated bolus chase peripheral MR angiography: Initial practical experiences and future directions of this work-in-progress
    • Ho V, et al. Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress. J Magn Reson Imaging. 1999;10:376-388.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 376-388
    • Ho, V.1
  • 62
    • 0034082821 scopus 로고    scopus 로고
    • Three-dimensional contrast-enhanced moving-bed infusion-tracking (MoBI-Track) peripheral mr angiography with flexible choice of imaging parameters for each field of view
    • Leiner T, et al. Three-dimensional contrast-enhanced moving-bed infusion-tracking (MoBI-Track) peripheral mr angiography with flexible choice of imaging parameters for each field of view. J Magn Reson Imaging. 2000;11:368-377.
    • (2000) J Magn Reson Imaging , vol.11 , pp. 368-377
    • Leiner, T.1
  • 64
    • 0025756746 scopus 로고
    • Significance of pedal arch for femoropopliteal vein bypass patency
    • Bartos J, et al. Significance of pedal arch for femoropopliteal vein bypass patency. Int Angiol. 1991;10:25-28.
    • (1991) Int Angiol , vol.10 , pp. 25-28
    • Bartos, J.1
  • 65
    • 0015767134 scopus 로고
    • Angiographic criteria for successful tibial arterial reconstructions
    • Imparato A, et al. Angiographic criteria for successful tibial arterial reconstructions. Surgery. 1973;74:830-838.
    • (1973) Surgery , vol.74 , pp. 830-838
    • Imparato, A.1
  • 66
    • 4444255653 scopus 로고    scopus 로고
    • Predicting venous enhancement in peripheral MRA using a two station timing bolus
    • Toronto: International Society of Magnetic Resonance in Medicine
    • Maki J, et al. Predicting venous enhancement in peripheral MRA using a two station timing bolus. In: Proceedings of the 11th Scientific Meeting and Exhibition. Toronto: International Society of Magnetic Resonance in Medicine, 2003.
    • (2003) Proceedings of the 11th Scientific Meeting and Exhibition
    • Maki, J.1
  • 67
    • 4444345171 scopus 로고    scopus 로고
    • 3D Gd-enhanced peripheral MR angiography using multistation SENSE (WakiTrak LS): An update
    • Toronto: International Society of Magnetic Resonance in Medicine
    • Maki J, et al. 3D Gd-enhanced peripheral MR angiography using multistation SENSE (WakiTrak LS): an update [Abstract]. In: 11th Scientific Meeting and Exhibition. Toronto: International Society of Magnetic Resonance in Medicine, 2003.
    • (2003) 11th Scientific Meeting and Exhibition
    • Maki, J.1
  • 68
    • 1442301539 scopus 로고    scopus 로고
    • High spatial resolution whole-body MR angiography featuring parallel imaging: Initial experience
    • Quick H, et al. High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2004;176:163-169.
    • (2004) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.176 , pp. 163-169
    • Quick, H.1
  • 69
    • 0036720426 scopus 로고    scopus 로고
    • Thorax: Low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution initial results
    • Finn J, et al. Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution initial results. Radiology. 2002;224:896-904.
    • (2002) Radiology , vol.224 , pp. 896-904
    • Finn, J.1
  • 70
    • 0035104550 scopus 로고    scopus 로고
    • Dynamic 3D MR angiography of the pulmonary arteries in under four seconds
    • Goyen M, et al. Dynamic 3D MR angiography of the pulmonary arteries in under four seconds. J Magn Reson Imaging. 2001;13:372-377.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 372-377
    • Goyen, M.1
  • 71
    • 0036789099 scopus 로고    scopus 로고
    • Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels
    • Swan J, et al. Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels. Radiology. 2002;225:43-52.
    • (2002) Radiology , vol.225 , pp. 43-52
    • Swan, J.1
  • 72
    • 0034976061 scopus 로고    scopus 로고
    • Contrast-enhanced magnetic resonance angiography of the carotid bifurcation using the time-resolved imaging of contrast kinetics (TRICKS) technique
    • Turski P, et al. Contrast-enhanced magnetic resonance angiography of the carotid bifurcation using the time-resolved imaging of contrast kinetics (TRICKS) technique. Top Magn Reson Imaging. 2001;12:175-181.
    • (2001) Top Magn Reson Imaging , vol.12 , pp. 175-181
    • Turski, P.1
  • 73
    • 0033984786 scopus 로고    scopus 로고
    • Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging
    • Vigen K, et al. Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging. Magn Reson Med. 2000;43: 170-176.
    • (2000) Magn Reson Med , vol.43 , pp. 170-176
    • Vigen, K.1
  • 74
    • 0033971791 scopus 로고    scopus 로고
    • Undersampled projection reconstruction applied to MR angiography
    • Peters D, et al. Undersampled projection reconstruction applied to MR angiography. Magn Reson Med. 2000;43:91-101.
    • (2000) Magn Reson Med , vol.43 , pp. 91-101
    • Peters, D.1
  • 75
    • 0036319895 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • Barger A, et al. Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med. 2002;48:297-305.
    • (2002) Magn Reson Med , vol.48 , pp. 297-305
    • Barger, A.1
  • 76
    • 0031656172 scopus 로고    scopus 로고
    • 3D time-resolved contrast-enhanced MR DSA: Advantages and tradeoffs
    • Mistretta C, et al. 3D time-resolved contrast-enhanced MR DSA: advantages and tradeoffs. Magn Reson Med. 1998;40:571-581.
    • (1998) Magn Reson Med , vol.40 , pp. 571-581
    • Mistretta, C.1
  • 78
    • 0042414065 scopus 로고    scopus 로고
    • Magnetic resonance imaging features of aortic diseases
    • Matsunaga N, et al. Magnetic resonance imaging features of aortic diseases. Top Magn Reson Imaging. 2003;14:253-266.
    • (2003) Top Magn Reson Imaging , vol.14 , pp. 253-266
    • Matsunaga, N.1
  • 79
    • 0034324591 scopus 로고    scopus 로고
    • Morphology and hemodynamics in dissection of the descending aorta: Assessment with MR imaging
    • Strotzer M, et al. Morphology and hemodynamics in dissection of the descending aorta: assessment with MR imaging. Acta Radiol. 2000;41:594-600.
    • (2000) Acta Radiol , vol.41 , pp. 594-600
    • Strotzer, M.1
  • 80
    • 0035202850 scopus 로고    scopus 로고
    • Abdominal magnetic resonance angiography: Principles and practical applications
    • Pereles F, Baskaran V. Abdominal magnetic resonance angiography: principles and practical applications. Top Magn Reson Imaging. 2001; 12:317-326.
    • (2001) Top Magn Reson Imaging , vol.12 , pp. 317-326
    • Pereles, F.1    Baskaran, V.2
  • 81
    • 0345016344 scopus 로고    scopus 로고
    • MRI for the diagnosis of pulmonary embolism
    • van Beek E, et al. MRI for the diagnosis of pulmonary embolism. J Magn Reson Imaging. 2003;18:627-640.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 627-640
    • Van Beek, E.1
  • 82
    • 0032881910 scopus 로고    scopus 로고
    • Pulmonary magnetic resonance angiography
    • Meaney J, et al. Pulmonary magnetic resonance angiography. J Magn Reson Imaging. 1999;10:326-338.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 326-338
    • Meaney, J.1
  • 83
    • 0035085971 scopus 로고    scopus 로고
    • Pulmonary arteriovenous malformations: Three-dimensional gadolinium-enhanced MR angiography-initial experience
    • Maki D, et al. Pulmonary arteriovenous malformations: three-dimensional gadolinium-enhanced MR angiography-initial experience. Radiology. 2001;219:243-246.
    • (2001) Radiology , vol.219 , pp. 243-246
    • Maki, D.1
  • 84
    • 0038383241 scopus 로고    scopus 로고
    • Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion: Initial results
    • Fink C, et al. Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion: initial results. Invest Radiol. 2003;38:482-488.
    • (2003) Invest Radiol , vol.38 , pp. 482-488
    • Fink, C.1
  • 88
  • 89
    • 4444232324 scopus 로고    scopus 로고
    • High-resolution MRA and fast perfusion imaging using integrated parallel acquisition techniques (iPAT) in the diagnosis of pulmonary arterial hypertension
    • Toronto
    • Nikolaou K, et al. High-resolution MRA and fast perfusion imaging using integrated parallel acquisition techniques (iPAT) in the diagnosis of pulmonary arterial hypertension: In: Proceedings of the 11th Scientific Meeting of the International Society for Magnetic Resonance in Medicine. Toronto, 2003.
    • (2003) Proceedings of the 11th Scientific Meeting of the International Society for Magnetic Resonance in Medicine
    • Nikolaou, K.1
  • 93
    • 4444355786 scopus 로고    scopus 로고
    • Quantitative assessment of regional pulmonary perfusion in the entire lung using 3D ultrafast dynamic CE MRI: Preliminary clinical experience in 22 subjects
    • Toronto
    • Ohno Y, et al. Quantitative assessment of regional pulmonary perfusion in the entire lung using 3D ultrafast dynamic CE MRI: preliminary clinical experience in 22 subjects. In: Proceedings of the 11th Scientific Meeting of the International Society for Magnetic Resonance in Medicine. Toronto, 2003.
    • (2003) Proceedings of the 11th Scientific Meeting of the International Society for Magnetic Resonance in Medicine
    • Ohno, Y.1
  • 95
    • 0034912645 scopus 로고    scopus 로고
    • Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography
    • Carroll T, et al. Carotid bifurcation: evaluation of time-resolved three-dimensional contrast-enhanced MR angiography. Radiology. 2001;220: 525-532.
    • (2001) Radiology , vol.220 , pp. 525-532
    • Carroll, T.1
  • 96
    • 0026078369 scopus 로고
    • MR angiography by multiple thin slab 3D acquisition
    • Parker D, Yuan C, Blatter D. MR angiography by multiple thin slab 3D acquisition. Magn Reson Med. 1991;17:434-451.
    • (1991) Magn Reson Med , vol.17 , pp. 434-451
    • Parker, D.1    Yuan, C.2    Blatter, D.3
  • 97
    • 0031660607 scopus 로고    scopus 로고
    • Intracranial vascular stenosis and occlusion: Comparison of 3D time-of-flight and 3D phase-contrast MR angiography
    • Oelerich M, et al. Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiography. Neuroradiology. 1998;40:567-573.
    • (1998) Neuroradiology , vol.40 , pp. 567-573
    • Oelerich, M.1
  • 98
    • 0029118567 scopus 로고
    • High resolution, magnetization transfer saturation, variable flip angle, time-of-flight MRA in the detection of intracranial vascular stenoses
    • Dagirmanjian A, et al. High resolution, magnetization transfer saturation, variable flip angle, time-of-flight MRA in the detection of intracranial vascular stenoses. J Comput Assist Tomogr. 1995;19:700-706.
    • (1995) J Comput Assist Tomogr , vol.19 , pp. 700-706
    • Dagirmanjian, A.1
  • 99
    • 0042324170 scopus 로고    scopus 로고
    • Intracranial aneurysms: Pathogenesis, rupture risk, treatment options
    • Wanke I, et al. Intracranial aneurysms: pathogenesis, rupture risk, treatment options. Fortsch Rontgenstr. 2003;175:1064-1070.
    • (2003) Fortsch Rontgenstr , vol.175 , pp. 1064-1070
    • Wanke, I.1
  • 100
    • 0033735394 scopus 로고    scopus 로고
    • Can noninvasive imaging accurately depict intracranial aneurysms? A systematic review
    • White P, Wardlaw J, Easton V. Can noninvasive imaging accurately depict intracranial aneurysms? A systematic review. Radiology. 2000;217: 361-370.
    • (2000) Radiology , vol.217 , pp. 361-370
    • White, P.1    Wardlaw, J.2    Easton, V.3
  • 101
    • 0028148172 scopus 로고
    • Blinded prospective evaluation of sensitivity of MR angiography to known intracranial aneurysms: Importance of aneurysm size
    • Huston J, et al. Blinded prospective evaluation of sensitivity of MR angiography to known intracranial aneurysms: importance of aneurysm size. Am J Neuroradiol. 1994;15:1607-1614.
    • (1994) Am J Neuroradiol , vol.15 , pp. 1607-1614
    • Huston, J.1
  • 102
    • 0033366633 scopus 로고    scopus 로고
    • Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: Correlation with digital subtraction angiography
    • Chung T, et al. Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: correlation with digital subtraction angiography. AJNR Am J Neuroradiol. 1999;20: 229-235.
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 229-235
    • Chung, T.1
  • 103
    • 0028087794 scopus 로고
    • Intracranial aneurysms: Diagnostic accuracy of three-dimensional, Fourier transform, time-of-flight MR angiography
    • Korogi Y, et al. Intracranial aneurysms: diagnostic accuracy of three-dimensional, Fourier transform, time-of-flight MR angiography. Radiology. 1994;193:181-186.
    • (1994) Radiology , vol.193 , pp. 181-186
    • Korogi, Y.1
  • 104
    • 0031105077 scopus 로고    scopus 로고
    • MR angiography of intracranial aneurysms: A comparison of 0.5 T and 1.5 T
    • Korogi Y, et al. MR angiography of intracranial aneurysms: a comparison of 0.5 T and 1.5 T. Comput Med Imaging Graph. 1997;21:111-116.
    • (1997) Comput Med Imaging Graph , vol.21 , pp. 111-116
    • Korogi, Y.1
  • 105
    • 0035008939 scopus 로고    scopus 로고
    • Intracranial aneurysms: CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort
    • White P, et al. Intracranial aneurysms: CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort. Radiology. 2001;219:739-749.
    • (2001) Radiology , vol.219 , pp. 739-749
    • White, P.1
  • 106
    • 0032471610 scopus 로고    scopus 로고
    • Diagnosis of intracranial aneurysms: Accuracy of MR angiography at 0.5 T
    • Grandin C, et al. Diagnosis of intracranial aneurysms: accuracy of MR angiography at 0.5 T. AJNR Am J Neuroradiol. 1998;19:245-252.
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 245-252
    • Grandin, C.1
  • 107
    • 0033917305 scopus 로고    scopus 로고
    • Intracranial aneurysms: Detection with gadolinium-enhanced dynamic three-dimensional MR angiography: Initial results
    • Metens T, et al. Intracranial aneurysms: detection with gadolinium-enhanced dynamic three-dimensional MR angiography: initial results. Radiology. 2000;216:39-46.
    • (2000) Radiology , vol.216 , pp. 39-46
    • Metens, T.1
  • 108
    • 1642541669 scopus 로고    scopus 로고
    • Improved image quality of intracranial aneurysms: 3.0T versus 1.5T time-of-flight MR angiography
    • Gibbs G, et al. Improved image quality of intracranial aneurysms: 3.0T versus 1.5T time-of-flight MR angiography. AJNR Am J Neuroradiol. 2004;25:84-87.
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 84-87
    • Gibbs, G.1
  • 109
    • 0022998188 scopus 로고
    • The intrinsic signal-to-noise ratio in NMR imaging
    • Edelstein W, et al. The intrinsic signal-to-noise ratio in NMR imaging. Magn Reson Med. 1986;3:604-618.
    • (1986) Magn Reson Med , vol.3 , pp. 604-618
    • Edelstein, W.1
  • 110
    • 0038236731 scopus 로고    scopus 로고
    • Magnetic resonance imaging at 3.0T: Challenges and advantages in clinical neurological imaging
    • Frayne R, et al. Magnetic resonance imaging at 3.0T: challenges and advantages in clinical neurological imaging. Invest Radiol. 2003;38:385-402.
    • (2003) Invest Radiol , vol.38 , pp. 385-402
    • Frayne, R.1
  • 111
    • 0034752732 scopus 로고    scopus 로고
    • High-resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experience
    • Bernstein M, et al. High-resolution intracranial and cervical MRA at 3.0T: technical considerations and initial experience. Magn Reson Med. 2001;46:955-962.
    • (2001) Magn Reson Med , vol.46 , pp. 955-962
    • Bernstein, M.1
  • 112
    • 0036099935 scopus 로고    scopus 로고
    • Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries
    • Al-Kwifi O, Emery D, Wilman A. Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries. Magn Reson Imaging. 2002;20:181-187.
    • (2002) Magn Reson Imaging , vol.20 , pp. 181-187
    • Al-Kwifi, O.1    Emery, D.2    Wilman, A.3
  • 113
    • 0036193421 scopus 로고    scopus 로고
    • Application of magnetization transfer at 3.0T in three-dimensional time-of-flight magnetic resonance angiography of the intracranial arteries
    • Thomas S, et al. Application of magnetization transfer at 3.0T in three-dimensional time-of-flight magnetic resonance angiography of the intracranial arteries. J Magn Reson Imaging. 2002;15:952-962.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 952-962
    • Thomas, S.1
  • 114
    • 0942297923 scopus 로고    scopus 로고
    • Sensitivity encoding (SENSE) for high spatial resolution time-of-flight MR angiography of the intracranial arteries at 3.0T
    • Willinek W, et al. Sensitivity encoding (SENSE) for high spatial resolution time-of-flight MR angiography of the intracranial arteries at 3.0T. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2004;176: 21-26.
    • (2004) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.176 , pp. 21-26
    • Willinek, W.1
  • 115
    • 4444234547 scopus 로고
    • Variable tip-angle slab selection for improved three-dimensional acquisition: Preliminary clinical experience in 80 patients
    • 1992. New York
    • Laub G, Purdy D. Variable tip-angle slab selection for improved three-dimensional acquisition: preliminary clinical experience in 80 patients. In: Proceedings of the Society of Magnetic Resonance Imaging (SMRI). 1992. New York, 1992.
    • (1992) Proceedings of the Society of Magnetic Resonance Imaging (SMRI)
    • Laub, G.1    Purdy, D.2
  • 116
    • 0028336633 scopus 로고
    • The effects of linearly increasing flip angles on 3-D inflow MR angiography
    • Nagele T, et al. The effects of linearly increasing flip angles on 3-D inflow MR angiography. Magn Reson Med. 1994;31:561-566.
    • (1994) Magn Reson Med , vol.31 , pp. 561-566
    • Nagele, T.1
  • 117
    • 0024542982 scopus 로고
    • Three-dimensional phase contrast angiography
    • Dumoulin C, et al. Three-dimensional phase contrast angiography. Magn Reson Med. 1989;9:139-149.
    • (1989) Magn Reson Med , vol.9 , pp. 139-149
    • Dumoulin, C.1
  • 118
    • 0026182092 scopus 로고
    • Encoding strategies for three-direction phase-contrast MR imaging of flow
    • Pelc N, et al. Encoding strategies for three-direction phase-contrast MR imaging of flow. J Magn Reson Imaging. 1991;1:405-413.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 405-413
    • Pelc, N.1
  • 119
    • 0343979490 scopus 로고
    • Current MR angiographic imaging techniques: A survey
    • Heidelberg: Springer Verlag
    • Kouwenhoven M. Current MR angiographic imaging techniques: a survey. In: Vascular Diagnostics. Heidelberg: Springer Verlag, 1995:375-400.
    • (1995) Vascular Diagnostics , pp. 375-400
    • Kouwenhoven, M.1
  • 120
    • 0141765862 scopus 로고    scopus 로고
    • Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE)
    • Beerbaum P, et al. Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding (SENSE). Circulation. 2003;108:1355-1361.
    • (2003) Circulation , vol.108 , pp. 1355-1361
    • Beerbaum, P.1
  • 121
    • 0033967792 scopus 로고    scopus 로고
    • Real-time color flow MRI
    • Nayak K, et al. Real-time color flow MRI. Magn Reson Med. 2000;43: 251-258.
    • (2000) Magn Reson Med , vol.43 , pp. 251-258
    • Nayak, K.1
  • 124
    • 0038301425 scopus 로고    scopus 로고
    • Contrast-enhanced peripheral MR angiography at 3.0 Tesla: Initial experience with a whole-body scanner in healthy volunteers
    • Leiner T, et al. Contrast-enhanced peripheral MR angiography at 3.0 Tesla: initial experience with a whole-body scanner in healthy volunteers. J Magn Reson Imaging. 2003;17:609-614.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 609-614
    • Leiner, T.1
  • 125
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann K, et al. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med. 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.1
  • 127
    • 0036206253 scopus 로고    scopus 로고
    • Detection and elimination of motion artifacts by regeneration of k-space
    • Bydder M, Larkman D, Hajnal J. Detection and elimination of motion artifacts by regeneration of k-space. Magn Reson Med. 2002;47:677-686.
    • (2002) Magn Reson Med , vol.47 , pp. 677-686
    • Bydder, M.1    Larkman, D.2    Hajnal, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.