메뉴 건너뛰기




Volumn 42, Issue 5, 1999, Pages 952-962

SENSE: Sensitivity encoding for fast MRI

Author keywords

Fast imaging; MRI; Receiver coil array; SENSE; Sensitivity encoding

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FOURIER ANALYSIS; NUCLEAR MAGNETIC RESONANCE IMAGING;

EID: 0032712873     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S     Document Type: Article
Times cited : (5910)

References (20)
  • 1
    • 33746803555 scopus 로고
    • Image formation by induced local interactions: Examples employing nuclear magnetic resonance
    • Lauterbur PC. Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature 1973;242:190-191.
    • (1973) Nature , vol.242 , pp. 190-191
    • Lauterbur, P.C.1
  • 3
    • 0023870882 scopus 로고    scopus 로고
    • Fast MRI data acquisition using multiple detectors
    • Hutchinson M, Raff U. Fast MRI data acquisition using multiple detectors. Magn Reson Med 1998;6:87-91.
    • (1998) Magn Reson Med , vol.6 , pp. 87-91
    • Hutchinson, M.1    Raff, U.2
  • 4
    • 0025777470 scopus 로고
    • A decoupled coil detector array for fast image acquisition in magnetic resonance imaging
    • Kwiat D, Einav S. A decoupled coil detector array for fast image acquisition in magnetic resonance imaging. Med Phys 1991;18:251-265.
    • (1991) Med Phys , vol.18 , pp. 251-265
    • Kwiat, D.1    Einav, S.2
  • 6
    • 0003227654 scopus 로고
    • Fast imaging method using multiple receiver coils with subencoding data set
    • San Francisco
    • Ra JB, Rim CY. Fast imaging method using multiple receiver coils with subencoding data set. In: Proceedings of the SMRM 10th Annual Meeting, San Francisco, 1991. p 1240.
    • (1991) Proceedings of the SMRM 10th Annual Meeting , pp. 1240
    • Ra, J.B.1    Rim, C.Y.2
  • 7
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Ultra-fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 11
    • 0023913522 scopus 로고
    • Correction for intensity falloff in surface coil magnetic resonance imaging
    • Brey WW, Narayana PA. Correction for intensity falloff in surface coil magnetic resonance imaging. Med Phys 1987;15:241-245.
    • (1987) Med Phys , vol.15 , pp. 241-245
    • Brey, W.W.1    Narayana, P.A.2
  • 12
    • 0345114101 scopus 로고
    • Reconstruction algorithm for images obtained with flexible multi-element synergy coils
    • San Francisco
    • Carlsen IC, Jensen D. Reconstruction algorithm for images obtained with flexible multi-element synergy coils. In: Proceedings of the SMR 2nd Annual Meeting, San Francisco, 1994. p 835.
    • (1994) Proceedings of the SMR 2nd Annual Meeting , pp. 835
    • Carlsen, I.C.1    Jensen, D.2
  • 13
  • 15
    • 0022863971 scopus 로고
    • An algorithm for compensation of surface-coil images for sensitivity of the surface coil
    • Haselgrove J, Prammer M. An algorithm for compensation of surface-coil images for sensitivity of the surface coil. Magn Reson Imaging 1986;4:469-472.
    • (1986) Magn Reson Imaging , vol.4 , pp. 469-472
    • Haselgrove, J.1    Prammer, M.2
  • 17
    • 0027319233 scopus 로고
    • Fast imaging using subencoding data sets from multiple detectors
    • Ra JB, Rim CY. Fast imaging using subencoding data sets from multiple detectors. Magn Reson Med 1993;30:142-145.
    • (1993) Magn Reson Med , vol.30 , pp. 142-145
    • Ra, J.B.1    Rim, C.Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.