메뉴 건너뛰기




Volumn 10, Issue 3, 1999, Pages 314-316

Contrast agents for MRA: Future directions

Author keywords

Contrast agents; MR angiography

Indexed keywords

GADOBENATE DIMEGLUMINE; GADOBUTROL; GADOFOSVESET; GADOLINIUM CHELATE; NUCLEAR MAGNETIC RESONANCE IMAGING AGENT; SUPERPARAMAGNETIC IRON OXIDE; ULTRASMALL SUPERPARAMAGNETIC IRON OXIDE; UNCLASSIFIED DRUG;

EID: 0032853901     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(199909)10:3<314::AID-JMRI13>3.0.CO;2-Y     Document Type: Review
Times cited : (74)

References (20)
  • 1
    • 0032851745 scopus 로고    scopus 로고
    • Off-label use and reimbursement for contrast media in MR
    • Runge V M, Knopp MV. Off-label use and reimbursement for contrast media in MR. J Magn Reson Imaging 1999;10:000-000.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 000-000
    • Runge, V.M.1    Knopp, M.V.2
  • 2
    • 0028351567 scopus 로고
    • Gadolinium-enhanced MR aortography
    • Prince MR. Gadolinium-enhanced MR aortography. Radiology 1994; 191:155-164.
    • (1994) Radiology , vol.191 , pp. 155-164
    • Prince, M.R.1
  • 5
    • 0345007884 scopus 로고    scopus 로고
    • Clinical utility of contrast-enhanced MR angiography
    • Bongartz GM, Boos M, Winter K, et al. Clinical utility of contrast-enhanced MR angiography. Eur Radiol 1997;7(suppl 5):178-186.
    • (1997) Eur Radiol , vol.7 , Issue.SUPPL. 5 , pp. 178-186
    • Bongartz, G.M.1    Boos, M.2    Winter, K.3
  • 6
    • 0028885944 scopus 로고
    • Effects of viscosity, cannula size and temperature in mechanical contrast media administration in CT and magnetic resonance tomography
    • Knopp M, Kauczor HU, Knopp MA, et al. Effects of viscosity, cannula size and temperature in mechanical contrast media administration in CT and magnetic resonance tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 1995;163:259-264.
    • (1995) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.163 , pp. 259-264
    • Knopp, M.1    Kauczor, H.U.2    Knopp, M.A.3
  • 7
    • 0032471003 scopus 로고    scopus 로고
    • Arterial phase three-dimensional gadolinium magnetic resonance angiography of the renal arteries: Strategies for timing and contrast media injection
    • Schoenberg SO, Knopp MV, Prince MR, Londy F, Knopp MA. Arterial phase three-dimensional gadolinium magnetic resonance angiography of the renal arteries: strategies for timing and contrast media injection. Invest Radiol 1998;33:506-514
    • (1998) Invest Radiol , vol.33 , pp. 506-514
    • Schoenberg, S.O.1    Knopp, M.V.2    Prince, M.R.3    Londy, F.4    Knopp, M.A.5
  • 8
    • 0028892584 scopus 로고
    • Pre-clinical evaluation of gadobutrol: A new, neutral, extracellular contrast agent for magnetic resonance imaging
    • Vogler H, Platzek J, Schuhmann GG, et al. Pre-clinical evaluation of gadobutrol: a new, neutral, extracellular contrast agent for magnetic resonance imaging. Eur J Radiol 1995;21:1-10.
    • (1995) Eur J Radiol , vol.21 , pp. 1-10
    • Vogler, H.1    Platzek, J.2    Schuhmann, G.G.3
  • 9
    • 0028102034 scopus 로고
    • Pharmacokinetics, dose proportionality, and tolerability of gadobutrol after single intravenous injection in healthy volunteers
    • Staks T, Schuhmann GG, Frenzel T, et al. Pharmacokinetics, dose proportionality, and tolerability of gadobutrol after single intravenous injection in healthy volunteers. Invest Radiol 1994;29:709-715.
    • (1994) Invest Radiol , vol.29 , pp. 709-715
    • Staks, T.1    Schuhmann, G.G.2    Frenzel, T.3
  • 10
    • 0031452736 scopus 로고    scopus 로고
    • Gadolinium chelates with weak binding to serum proteins. A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging
    • Cavagna FM, Maggioni F, Castelli PM, et al. Gadolinium chelates with weak binding to serum proteins. A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging. Invest Radiol 1997;32:780-796.
    • (1997) Invest Radiol , vol.32 , pp. 780-796
    • Cavagna, F.M.1    Maggioni, F.2    Castelli, P.M.3
  • 11
    • 0000947364 scopus 로고    scopus 로고
    • Comparison of the efficacy of Gd-BOPTA and Gd-DTPA for MR angiography: A phase I pilot study
    • Sydney
    • Knopp MV, Schoenberg SO, Rehm C, et al. Comparison of the efficacy of Gd-BOPTA and Gd-DTPA for MR Angiography: a phase I pilot study. In: Proceding of the ISMRM. Sydney, 1998. p 174.
    • (1998) Proceding of the ISMRM , pp. 174
    • Knopp, M.V.1    Schoenberg, S.O.2    Rehm, C.3
  • 12
    • 0033277563 scopus 로고    scopus 로고
    • Safety, tolerance, biodistribution and MR imaging enhancement of the liver with Gd-BOPTA: Results of clinical pharmacologic and pilot imaging studies in non-patient and patient volunteers
    • Spinazzi A, Lorusso V, Pirovano G, Kirchin MA. Safety, tolerance, biodistribution and MR imaging enhancement of the liver with Gd-BOPTA: results of clinical pharmacologic and pilot imaging studies in non-patient and patient volunteers. Acta Radiol 1999;6: 282-291.
    • (1999) Acta Radiol , vol.6 , pp. 282-291
    • Spinazzi, A.1    Lorusso, V.2    Pirovano, G.3    Kirchin, M.A.4
  • 14
    • 0031836465 scopus 로고    scopus 로고
    • MS-325: Albumin-targeted contrast agent for MR angiography
    • Lauffer RB, Parmelee DJ, Dunham SU, et al. MS-325: albumin-targeted contrast agent for MR angiography. Radiology 1998;207: 529-538.
    • (1998) Radiology , vol.207 , pp. 529-538
    • Lauffer, R.B.1    Parmelee, D.J.2    Dunham, S.U.3
  • 15
    • 0031862273 scopus 로고    scopus 로고
    • Steady-state and dynamic MR angiography with MS-325: Initial experience in humans
    • Grist TM, Korosec FR, Peters DC, et al. Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 1998;207:539-544.
    • (1998) Radiology , vol.207 , pp. 539-544
    • Grist, T.M.1    Korosec, F.R.2    Peters, D.C.3
  • 16
    • 0032040320 scopus 로고    scopus 로고
    • Blood-pool contrast agents for MRI: A critical evaluation
    • Koenig SH, Kellar KE. Blood-pool contrast agents for MRI: a critical evaluation. Acad Radiol 1998;5(suppl 1):200-205.
    • (1998) Acad Radiol , vol.5 , Issue.SUPPL. 1 , pp. 200-205
    • Koenig, S.H.1    Kellar, K.E.2
  • 18
    • 0002028762 scopus 로고    scopus 로고
    • Open-label, phase 1 trial of a new blood pool contrast agent (NC100150) in 12 healthy volunteers: Safety and vascular imaging characteristics
    • Sydney
    • Wildermuth S, Dubno B, Romanowski BJ, et al. Open-label, phase 1 trial of a new blood pool contrast agent (NC100150) in 12 healthy volunteers: safety and vascular imaging characteristics. Proceedings of the 6th meeting of the ISMRM, Sydney, 1998; 171.
    • (1998) Proceedings of the 6th Meeting of the ISMRM , pp. 171
    • Wildermuth, S.1    Dubno, B.2    Romanowski, B.J.3
  • 19
    • 0031604211 scopus 로고    scopus 로고
    • Value of blood pool contrast agents in magnetic resonance angiography of the pelvis and lower extremities
    • Saeed M, Wendland MF, Engelbrecht M, Sakuma H, Higgins CB. Value of blood pool contrast agents in magnetic resonance angiography of the pelvis and lower extremities. Eur Radiol 1998;8:1047-1053.
    • (1998) Eur Radiol , vol.8 , pp. 1047-1053
    • Saeed, M.1    Wendland, M.F.2    Engelbrecht, M.3    Sakuma, H.4    Higgins, C.B.5
  • 20
    • 0032968339 scopus 로고    scopus 로고
    • Safety and preliminary findings with the intravascular contrast agent NC100150 Injection for MR coronary angiography
    • Taylor AM, Panting JR, Keegan J, et al. Safety and preliminary findings with the intravascular contrast agent NC100150 Injection for MR coronary angiography. J Magn Reson Imaging 1999;9:220-227.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 220-227
    • Taylor, A.M.1    Panting, J.R.2    Keegan, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.