메뉴 건너뛰기




Volumn 15, Issue 4, 2004, Pages 223-236

SMASH, SENSE, PILS, GRAPPA. How to Choose the Optimal Method

Author keywords

GRAPPA; MRI; Parallel imaging; PILS; SENSE; SMASH

Indexed keywords

IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; NUCLEAR MAGNETIC RESONANCE IMAGING; PARALLEL DESIGN; PRIORITY JOURNAL; REVIEW; TECHNIQUE;

EID: 5044228870     PISSN: 08993459     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rmr.0000136558.09801.dd     Document Type: Review
Times cited : (357)

References (40)
  • 1
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med. 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 3
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 4
    • 0032425458 scopus 로고    scopus 로고
    • AUTO-SMASH: A self-calibrating technique for SMASH imaging: SiMultaneous Acquisition of Spatial Harmonics
    • Jakob PM, Griswold MA, Edelman RR, et al. AUTO-SMASH: a self-calibrating technique for SMASH imaging: SiMultaneous Acquisition of Spatial Harmonics. MAGMA. 1998;7:42-54.
    • (1998) MAGMA , vol.7 , pp. 42-54
    • Jakob, P.M.1    Griswold, M.A.2    Edelman, R.R.3
  • 8
    • 0033772492 scopus 로고    scopus 로고
    • Partially parallel imaging with localized sensitivities (PILS)
    • Griswold MA, Jakob PM, Nittka M, et al. Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med. 2000;44:602-609.
    • (2000) Magn Reson Med , vol.44 , pp. 602-609
    • Griswold, M.A.1    Jakob, P.M.2    Nittka, M.3
  • 9
    • 0033854213 scopus 로고    scopus 로고
    • Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
    • Kyriakos WE, Panych LP, Kacher DF, et al. Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP). Magn Reson Med. 2000;44:301-308.
    • (2000) Magn Reson Med , vol.44 , pp. 301-308
    • Kyriakos, W.E.1    Panych, L.P.2    Kacher, D.F.3
  • 10
    • 0033856106 scopus 로고    scopus 로고
    • Tailored SMASH image reconstructions for robust in vivo parallel MR imaging
    • Sodickson DK. Tailored SMASH image reconstructions for robust in vivo parallel MR imaging. Magn Reson Med. 2000;44:243-251.
    • (2000) Magn Reson Med , vol.44 , pp. 243-251
    • Sodickson, D.K.1
  • 11
    • 0036892919 scopus 로고    scopus 로고
    • Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging
    • de Zwart JA, van Gelderen P, Kellman P, et al. Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging. Magn Reson Med. 2002;48:1011-1020.
    • (2002) Magn Reson Med , vol.48 , pp. 1011-1020
    • De Zwart, J.A.1    Van Gelderen, P.2    Kellman, P.3
  • 12
    • 0036187917 scopus 로고    scopus 로고
    • Combination of signals from array coils using image-based estimation of coil sensitivity profiles
    • Bydder M, Larkman DJ, Hajnal JV. Combination of signals from array coils using image-based estimation of coil sensitivity profiles. Magn Reson Med. 2002;47:539-548.
    • (2002) Magn Reson Med , vol.47 , pp. 539-548
    • Bydder, M.1    Larkman, D.J.2    Hajnal, J.V.3
  • 13
    • 0034060592 scopus 로고    scopus 로고
    • Adaptive reconstruction of phased array MR imagery
    • Walsh DO, Gmitro AF, Marcellin MW. Adaptive reconstruction of phased array MR imagery. Magn Reson Med. 2000;43:682-690.
    • (2000) Magn Reson Med , vol.43 , pp. 682-690
    • Walsh, D.O.1    Gmitro, A.F.2    Marcellin, M.W.3
  • 15
    • 0033959571 scopus 로고    scopus 로고
    • Cardiac real-time imaging using SENSE. SENSitivity encoding scheme
    • Weiger M, Pruessmann KP, Boesiger P. Cardiac real-time imaging using SENSE. SENSitivity encoding scheme. Magn Reson Med. 2000;43:177-184.
    • (2000) Magn Reson Med , vol.43 , pp. 177-184
    • Weiger, M.1    Pruessmann, K.P.2    Boesiger, P.3
  • 17
    • 0032997647 scopus 로고    scopus 로고
    • Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH)
    • Griswold MA, Jakob PM, Chen Q, et al. Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH). Magn Reson Med. 1999;41:1236-1245.
    • (1999) Magn Reson Med , vol.41 , pp. 1236-1245
    • Griswold, M.A.1    Jakob, P.M.2    Chen, Q.3
  • 18
    • 0036290659 scopus 로고    scopus 로고
    • Diffusion tensor imaging using single-shot SENSE-EPI
    • Bammer R, Auer M, Keeling SL, et al. Diffusion tensor imaging using single-shot SENSE-EPI. Magn Reson Med. 2002;48:128-136.
    • (2002) Magn Reson Med , vol.48 , pp. 128-136
    • Bammer, R.1    Auer, M.2    Keeling, S.L.3
  • 19
    • 0034850918 scopus 로고    scopus 로고
    • Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE)
    • Bammer R, Keeling SL, Augustin M, et al. Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med. 2001;46:548-554.
    • (2001) Magn Reson Med , vol.46 , pp. 548-554
    • Bammer, R.1    Keeling, S.L.2    Augustin, M.3
  • 20
    • 0034878536 scopus 로고    scopus 로고
    • An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging
    • Larkman DJ, deSouza NM, Bydder M, et al. An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging. J Magn Reson Imaging. 2001; 14:329-335.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 329-335
    • Larkman, D.J.1    DeSouza, N.M.2    Bydder, M.3
  • 21
    • 0037308718 scopus 로고    scopus 로고
    • Resolution enhancement in lung 1H imaging using parallel imaging methods
    • Heidemann RM, Griswold MA, Kiefer B, et al. Resolution enhancement in lung 1H imaging using parallel imaging methods. Magn Reson Med. 2003;49:391-394.
    • (2003) Magn Reson Med , vol.49 , pp. 391-394
    • Heidemann, R.M.1    Griswold, M.A.2    Kiefer, B.3
  • 22
    • 5044228697 scopus 로고    scopus 로고
    • Contrast enhanced 3D MR perfusion imaging of the lungs using parallel imaging techniques
    • Toronto
    • Fink C, Bock M, Puderbach M, et al. Contrast enhanced 3D MR perfusion imaging of the lungs using parallel imaging techniques. Proceedings of the 11th Annual Meeting of the ISMRM, Toronto, 2003:1366.
    • (2003) Proceedings of the 11th Annual Meeting of the ISMRM , pp. 1366
    • Fink, C.1    Bock, M.2    Puderbach, M.3
  • 23
    • 5044236432 scopus 로고    scopus 로고
    • Single breath-hold real-time evaluation of cardiac function: Improvement of temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithms
    • Toronto
    • Wintersperger BJ, Nikolaou K, Schoenberg SO, et al. Single breath-hold real-time evaluation of cardiac function: improvement of temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithms. Proceedings of the 11th Annual Meeting of the ISMRM, Toronto, 2003:1587.
    • (2003) Proceedings of the 11th Annual Meeting of the ISMRM , pp. 1587
    • Wintersperger, B.J.1    Nikolaou, K.2    Schoenberg, S.O.3
  • 24
    • 0009627909 scopus 로고    scopus 로고
    • Minimizing distortions and blurring in diffusion weighted single shot EPI using high performance gradients in combination with parallel imaging
    • Glasgow
    • Heidemann RM, Griswold MA, Porter D, et al. Minimizing distortions and blurring in diffusion weighted single shot EPI using high performance gradients in combination with parallel imaging. Proceedings of the 9th Annual Meeting of the ISMRM, Glasgow, 2001:169.
    • (2001) Proceedings of the 9th Annual Meeting of the ISMRM , pp. 169
    • Heidemann, R.M.1    Griswold, M.A.2    Porter, D.3
  • 27
    • 5044222956 scopus 로고    scopus 로고
    • Improving true-FISP parallel cine imaging using a new data-acquisition scheme for coil sensitivity calibration
    • Toronto
    • Zhang Q, Park J, Li D, et al. Improving true-FISP parallel cine imaging using a new data-acquisition scheme for coil sensitivity calibration. Proceedings of the 11th Annual Meeting of the ISMRM, Toronto, 2003:2329.
    • (2003) Proceedings of the 11th Annual Meeting of the ISMRM , pp. 2329
    • Zhang, Q.1    Park, J.2    Li, D.3
  • 28
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med. 2001;45:846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 30
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med. 1999;42:813-828.
    • (1999) Magn Reson Med , vol.42 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 31
    • 0242385481 scopus 로고    scopus 로고
    • Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations
    • Ohliger MA, Grant AK, Sodickson DK. Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations. Magn Reson Med. 2003;50:1018-1030.
    • (2003) Magn Reson Med , vol.50 , pp. 1018-1030
    • Ohliger, M.A.1    Grant, A.K.2    Sodickson, D.K.3
  • 32
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med. 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 34
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Börnert P, et al. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med. 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Börnert, P.3
  • 36
    • 0036847423 scopus 로고    scopus 로고
    • Sensitivity-encoded single-shot spiral imaging for reduced susceptibility in BOLD fMRI
    • Weiger M, Pruessmann KP, Österbauer R, et al. Sensitivity-encoded single-shot spiral imaging for reduced susceptibility in BOLD fMRI. Magn Reson Med. 2002;48:860-866.
    • (2002) Magn Reson Med , vol.48 , pp. 860-866
    • Weiger, M.1    Pruessmann, K.P.2    Österbauer, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.