-
1
-
-
59249089319
-
Comparison between the prognostic value of left ventricular function and myocardial perfusion reserve in patients with ischemic heart disease
-
PID: 19164219
-
Tio RA, Dabeshlim A, Siebelink H-MJ, Sutter J de, Hillege HL, Zeebregts CJ, et al. Comparison between the prognostic value of left ventricular function and myocardial perfusion reserve in patients with ischemic heart disease. J Nucl Med 2009;50:214-9. doi:10.2967/jnumed.108.054395.
-
(2009)
J Nucl Med
, vol.50
, pp. 214-219
-
-
Tio, R.A.1
Dabeshlim, A.2
Siebelink, H.-M.J.3
de Sutter, J.4
Hillege, H.L.5
Zeebregts, C.J.6
-
2
-
-
67649385766
-
Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography: Added value of coronary flow reserve
-
PID: 19573732
-
Herzog BA, Husmann L, Valenta I, Gaemperli O, Siegrist PT, Tay FM, et al. Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography: Added value of coronary flow reserve. J Am Coll Cardiol 2009;54:150-6. doi:10.1016/j.jacc.2009.02.069.
-
(2009)
J Am Coll Cardiol
, vol.54
, pp. 150-156
-
-
Herzog, B.A.1
Husmann, L.2
Valenta, I.3
Gaemperli, O.4
Siegrist, P.T.5
Tay, F.M.6
-
3
-
-
79961174089
-
Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia
-
PID: 21816311
-
Ziadi MC, deKemp RA, Williams KA, Guo A, Chow BJW, Renaud JM, et al. Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia. J Am Coll Cardiol 2011;58:740-8. doi:10.1016/j.jacc.2011.01.065.
-
(2011)
J Am Coll Cardiol
, vol.58
, pp. 740-748
-
-
Ziadi, M.C.1
deKemp, R.A.2
Williams, K.A.3
Guo, A.4
Chow, B.J.W.5
Renaud, J.M.6
-
4
-
-
81355146433
-
Improved cardiac risk assessment with noninvasive measures of coronary flow reserve
-
PID: 22007073
-
Murthy VL, Naya M, Foster CR, Hainer J, Gaber M, Di Carli G, et al. Improved cardiac risk assessment with noninvasive measures of coronary flow reserve. Circulation 2011;124:2215-24. doi:10.1161/CIRCULATIONAHA.111.050427.
-
(2011)
Circulation
, vol.124
, pp. 2215-2224
-
-
Murthy, V.L.1
Naya, M.2
Foster, C.R.3
Hainer, J.4
Gaber, M.5
Di Carli, G.6
-
5
-
-
84867266956
-
Association between coronary vascular dysfunction and cardiac mortality in patients with and without diabetes mellitus
-
COI: 1:CAS:528:DC%2BC38XhsVKrsbbE, PID: 22919001
-
Murthy VL, Naya M, Foster CR, Gaber M, Hainer J, Klein J, et al. Association between coronary vascular dysfunction and cardiac mortality in patients with and without diabetes mellitus. Circulation 2012;126:1858-68. doi:10.1161/CIRCULATIONAHA.112.120402.
-
(2012)
Circulation
, vol.126
, pp. 1858-1868
-
-
Murthy, V.L.1
Naya, M.2
Foster, C.R.3
Gaber, M.4
Hainer, J.5
Klein, J.6
-
6
-
-
82955196342
-
Quantification of myocardial blood flow and flow reserve: Technical aspects
-
PID: 20596841
-
Klein R, Beanlands R, deKemp R. Quantification of myocardial blood flow and flow reserve: Technical aspects. J Nucl Cardiol 2010;17:555-70.
-
(2010)
J Nucl Cardiol
, vol.17
, pp. 555-570
-
-
Klein, R.1
Beanlands, R.2
deKemp, R.3
-
7
-
-
77955609487
-
The challenge of detector designs for PET
-
Lewellen TK. The challenge of detector designs for PET. Am J Roentgenol 2010;195:301-9. doi:10.2214/AJR.10.4741.
-
(2010)
Am J Roentgenol
, vol.195
, pp. 301-309
-
-
Lewellen, T.K.1
-
9
-
-
0020703921
-
Dynamic imaging with high resolution time-of-flight PET camera—TOFPET I
-
Mullani NA, Gaeta J, Yerian K, Wong W-H, Hartz RK, Philippe EA, et al. Dynamic imaging with high resolution time-of-flight PET camera—TOFPET I. IEEE Trans Nucl Sci 1984;31:609-13. doi:10.1109/TNS.1984.4333329.
-
(1984)
IEEE Trans Nucl Sci
, vol.31
, pp. 609-613
-
-
Mullani, N.A.1
Gaeta, J.2
Yerian, K.3
Wong, W.-H.4
Hartz, R.K.5
Philippe, E.A.6
-
10
-
-
0028300781
-
The super PET 3000-E: A PET scanner designed for high count rate cardiac applications
-
COI: 1:STN:280:DyaK2czhsFWhtw%3D%3D, PID: 8040459
-
Ter-Pogossian MM, Ficke DC, Beecher DE, Hoffman GR, Bergmann SR. The super PET 3000-E: A PET scanner designed for high count rate cardiac applications. J Comput Assist Tomogr 1994;18:661-9.
-
(1994)
J Comput Assist Tomogr
, vol.18
, pp. 661-669
-
-
Ter-Pogossian, M.M.1
Ficke, D.C.2
Beecher, D.E.3
Hoffman, G.R.4
Bergmann, S.R.5
-
11
-
-
0025414253
-
Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalents counts
-
Strother SC, Casey ME, Hoffman EJ. Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalents counts. IEEE Trans Nucl Sci 1990;37:783-8. doi:10.1109/23.106715.
-
(1990)
IEEE Trans Nucl Sci
, vol.37
, pp. 783-788
-
-
Strother, S.C.1
Casey, M.E.2
Hoffman, E.J.3
-
12
-
-
0023814978
-
Investigation of count rate and deadtime characteristics of a high resolution PET system
-
COI: 1:STN:280:DyaL1M%2FgvFSkug%3D%3D, PID: 3262635
-
Germano G, Hoffman EJ. Investigation of count rate and deadtime characteristics of a high resolution PET system. J Comput Assist Tomogr 1988;12:836-46.
-
(1988)
J Comput Assist Tomogr
, vol.12
, pp. 836-846
-
-
Germano, G.1
Hoffman, E.J.2
-
13
-
-
0025418227
-
A study of data loss and mispositioning due to pileup in 2-D detectors in PET
-
Germano G, Hoffman EJ. A study of data loss and mispositioning due to pileup in 2-D detectors in PET. IEEE Trans Nucl Sci 1990;37:671-5. doi:10.1109/23.106696.
-
(1990)
IEEE Trans Nucl Sci
, vol.37
, pp. 671-675
-
-
Germano, G.1
Hoffman, E.J.2
-
14
-
-
79953683986
-
Physical and clinical performance of the mCT time-of-flight PET/CT scanner
-
COI: 1:STN:280:DC%2BC3MzotlGitA%3D%3D, PID: 21427485
-
Jakoby BW, Bercier Y, Conti M, Casey ME, Bendriem B, Townsend DW. Physical and clinical performance of the mCT time-of-flight PET/CT scanner. Phys Med Biol 2011;56:2375. doi:10.1088/0031-9155/56/8/004.
-
(2011)
Phys Med Biol
, vol.56
, pp. 2375
-
-
Jakoby, B.W.1
Bercier, Y.2
Conti, M.3
Casey, M.E.4
Bendriem, B.5
Townsend, D.W.6
-
15
-
-
80053578484
-
Physical performance of the new hybrid PET/CT discovery-690
-
COI: 1:STN:280:DC%2BC3Mbgs1yqug%3D%3D, PID: 21992359
-
Bettinardi V, Presotto L, Rapisarda E, Picchio M, Gianolli L, Gilardi MC. Physical performance of the new hybrid PET/CT discovery-690. Med Phys 2011;38:5394-411. doi:10.1118/1.3635220.
-
(2011)
Med Phys
, vol.38
, pp. 5394-5411
-
-
Bettinardi, V.1
Presotto, L.2
Rapisarda, E.3
Picchio, M.4
Gianolli, L.5
Gilardi, M.C.6
-
16
-
-
84903639288
-
Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions
-
PID: 24955921
-
Kolthammer JA, Su K-H, Grover A, Narayanan M, Jordan DW, Muzic RF. Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions. Phys Med Biol 2014;59:3843. doi:10.1088/0031-9155/59/14/3843.
-
(2014)
Phys Med Biol
, vol.59
, pp. 3843
-
-
Kolthammer, J.A.1
Su, K.-H.2
Grover, A.3
Narayanan, M.4
Jordan, D.W.5
Muzic, R.F.6
-
17
-
-
25444442095
-
First experimental results of time-of-flight reconstruction on an LSO PET scanner
-
PID: 16177486
-
Conti M, Bendriem B, Casey M, Chen M, Kehren F, Michel C, et al. First experimental results of time-of-flight reconstruction on an LSO PET scanner. Phys Med Biol 2005;50:4507. doi:10.1088/0031-9155/50/19/006.
-
(2005)
Phys Med Biol
, vol.50
, pp. 4507
-
-
Conti, M.1
Bendriem, B.2
Casey, M.3
Chen, M.4
Kehren, F.5
Michel, C.6
-
18
-
-
34247230296
-
Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities
-
PID: 17332626
-
Surti S, Kuhn A, Werner ME, Perkins AE, Kolthammer J, Karp JS. Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med 2007;48:471-80.
-
(2007)
J Nucl Med
, vol.48
, pp. 471-480
-
-
Surti, S.1
Kuhn, A.2
Werner, M.E.3
Perkins, A.E.4
Kolthammer, J.5
Karp, J.S.6
-
19
-
-
46149085183
-
Quantitative accuracy of PET/CT for image-based kinetic analysis
-
PID: 18697532
-
Seo Y, Teo B-K, Hadi M, Schreck C, Bacharach SL, Hasegawa BH. Quantitative accuracy of PET/CT for image-based kinetic analysis. Med Phys 2008;35:3086-9. doi:10.1118/1.2937439.
-
(2008)
Med Phys
, vol.35
, pp. 3086-3089
-
-
Seo, Y.1
Teo, B.-K.2
Hadi, M.3
Schreck, C.4
Bacharach, S.L.5
Hasegawa, B.H.6
-
20
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
COI: 1:STN:280:DyaL287hslWqsQ%3D%3D, PID: 2868172
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
21
-
-
38349057755
-
Tracer kinetic modeling in PET
-
Bailey DL, Townsend DW, Valk PE, Maisey MN, (eds), Springer, London
-
Carson RE. Tracer kinetic modeling in PET. In: Bailey DL, Townsend DW, Valk PE, Maisey MN, editors. Positron emission tomography. London: Springer; 2005. p. 127-59.
-
(2005)
Positron emission tomography
, pp. 127-159
-
-
Carson, R.E.1
-
22
-
-
0027394099
-
Sampling requirements for dynamic cardiac PET studies using image-derived input functions
-
COI: 1:STN:280:DyaK3s7nvF2lug%3D%3D, PID: 8441036
-
Raylman RR, Caraher JM, Hutchins GD. Sampling requirements for dynamic cardiac PET studies using image-derived input functions. J Nucl Med 1993;34:440-7.
-
(1993)
J Nucl Med
, vol.34
, pp. 440-447
-
-
Raylman, R.R.1
Caraher, J.M.2
Hutchins, G.D.3
-
23
-
-
34250656647
-
Clinical myocardial perfusion PET/CT
-
PID: 17475968
-
Di Carli MF, Dorbala S, Meserve J, El Fakhri G, Sitek A, Moore SC. Clinical myocardial perfusion PET/CT. J Nucl Med 2007;48:783-93.
-
(2007)
J Nucl Med
, vol.48
, pp. 783-793
-
-
Di Carli, M.F.1
Dorbala, S.2
Meserve, J.3
El Fakhri, G.4
Sitek, A.5
Moore, S.C.6
-
24
-
-
18344383977
-
Positron emission tomography of the heart: Methodology, findings in the normal and the diseased heart, and clinical applications
-
Phelps ME, (ed), Springer, New York
-
Schelbert HR. Positron emission tomography of the heart: Methodology, findings in the normal and the diseased heart, and clinical applications. In: Phelps ME, editor. PET: Molecular imaging and its biological applications. 1st ed. New York: Springer; 2004. p. 389-508.
-
(2004)
PET: Molecular imaging and its biological applications
, pp. 389-508
-
-
Schelbert, H.R.1
-
25
-
-
84881396378
-
Optimized dynamic framing for PET-based myocardial blood flow estimation
-
PID: 23912223
-
Kolthammer JA, Muzic RF. Optimized dynamic framing for PET-based myocardial blood flow estimation. Phys Med Biol 2013;58:5783. doi:10.1088/0031-9155/58/16/5783.
-
(2013)
Phys Med Biol
, vol.58
, pp. 5783
-
-
Kolthammer, J.A.1
Muzic, R.F.2
-
26
-
-
84915809372
-
Effects of temporal sampling on PET myocardial blood flow estimates
-
Lee B, Moody J, Murthy V, Corbett J, Ficaro E. Effects of temporal sampling on PET myocardial blood flow estimates. Soc Nucl Med Annu Meet Abstr 2014;55:1775.
-
(2014)
Soc Nucl Med Annu Meet Abstr
, vol.55
, pp. 1775
-
-
Lee, B.1
Moody, J.2
Murthy, V.3
Corbett, J.4
Ficaro, E.5
-
27
-
-
34047252834
-
Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography
-
COI: 1:STN:280:DC%2BD2s%2FjtVyktg%3D%3D, PID: 17228112
-
Klein R, Adler A, Beanlands RS, deKemp RA. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol 2007;52:659-73. doi:10.1088/0031-9155/52/3/009.
-
(2007)
Phys Med Biol
, vol.52
, pp. 659-673
-
-
Klein, R.1
Adler, A.2
Beanlands, R.S.3
deKemp, R.A.4
-
28
-
-
34249697435
-
Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?
-
PID: 17556173
-
deKemp RA, Yoshinaga K, Beanlands RSB. Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow? J Nucl Cardiol 2007;14:380-97.
-
(2007)
J Nucl Cardiol
, vol.14
, pp. 380-397
-
-
deKemp, R.A.1
Yoshinaga, K.2
Beanlands, R.S.B.3
-
29
-
-
84866920393
-
Assessment of a protocol for routine simultaneous myocardial blood flow measurement and standard myocardial perfusion imaging with rubidium-82 on a high count rate positron emission tomography system
-
PID: 22760302
-
Tout D, Tonge C, Muthu S, Arumugam P. Assessment of a protocol for routine simultaneous myocardial blood flow measurement and standard myocardial perfusion imaging with rubidium-82 on a high count rate positron emission tomography system. Nucl Med Commun 2012;33:1202-11. doi:10.1097/MNM.0b013e3283567554.
-
(2012)
Nucl Med Commun.
, vol.33
, pp. 1202-1211
-
-
Tout, D.1
Tonge, C.2
Muthu, S.3
Arumugam, P.4
-
30
-
-
77950633047
-
A Scatter calibration technique for dynamic brain imaging in high resolution PET
-
Cheng J-C, Blinder S, Rahmim A, Sossi V. A Scatter calibration technique for dynamic brain imaging in high resolution PET. IEEE Trans Nucl Sci 2010;57:225-33. doi:10.1109/TNS.2009.2031643.
-
(2010)
IEEE Trans Nucl Sci
, vol.57
, pp. 225-233
-
-
Cheng, J.-C.1
Blinder, S.2
Rahmim, A.3
Sossi, V.4
-
31
-
-
35348975173
-
Extension of single scatter simulation to scatter correction of time-of-flight PET
-
Watson CC. Extension of single scatter simulation to scatter correction of time-of-flight PET. IEEE Trans Nucl Sci 2007;54:1679-86. doi:10.1109/TNS.2007.901227.
-
(2007)
IEEE Trans Nucl Sci
, vol.54
, pp. 1679-1686
-
-
Watson, C.C.1
-
32
-
-
84922002587
-
Commentary: An eye on PET quantification
-
Walker MD, Sossi V. Commentary: An eye on PET quantification. Mol Imaging Biol 2014;17:1-3. doi:10.1007/s11307-014-0791-7.
-
(2014)
Mol Imaging Biol
, vol.17
, pp. 1-3
-
-
Walker, M.D.1
Sossi, V.2
-
33
-
-
84872042740
-
Cardiac PET/CT misregistration causes significant changes in estimated myocardial blood flow
-
PID: 23090213
-
Rajaram M, Tahari AK, Lee AH, Lodge MA, Tsui B, Nekolla S, et al. Cardiac PET/CT misregistration causes significant changes in estimated myocardial blood flow. J Nucl Med 2013;54:50-4. doi:10.2967/jnumed.112.108183.
-
(2013)
J Nucl Med
, vol.54
, pp. 50-54
-
-
Rajaram, M.1
Tahari, A.K.2
Lee, A.H.3
Lodge, M.A.4
Tsui, B.5
Nekolla, S.6
-
34
-
-
0029528722
-
Quantitative PET with positron emitters that emit prompt gamma rays
-
COI: 1:STN:280:DC%2BD1c%2FmtlOitw%3D%3D, PID: 18215872
-
Martin CC, Christian BT, Satter MR, Nickerson LDH, Nickles RJ. Quantitative PET with positron emitters that emit prompt gamma rays. IEEE Trans Med Imaging 1995;14:681-7. doi:10.1109/42.476109.
-
(1995)
IEEE Trans Med Imaging
, vol.14
, pp. 681-687
-
-
Martin, C.C.1
Christian, B.T.2
Satter, M.R.3
Nickerson, L.D.H.4
Nickles, R.J.5
-
36
-
-
77953324366
-
Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT
-
PID: 19937169
-
Esteves FP, Nye JA, Khan A, Folks RD, Halkar RK, Garcia EV, et al. Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT. J Nucl Cardiol 2010;17:247-53.
-
(2010)
J Nucl Cardiol
, vol.17
, pp. 247-253
-
-
Esteves, F.P.1
Nye, J.A.2
Khan, A.3
Folks, R.D.4
Halkar, R.K.5
Garcia, E.V.6
-
37
-
-
84894714081
-
Clinical interpretation standards and quality assurance for the multicenter PET/CT Trial: 82Rb as an alternative radiopharmaceutical for myocardial imaging
-
Renaud JM, Mylonas I, McArdle B, Dowsley T, Yip K, Turcotte E, et al. Clinical interpretation standards and quality assurance for the multicenter PET/CT Trial: 82Rb as an alternative radiopharmaceutical for myocardial imaging. J Nucl Med 2014. doi:10.2967/jnumed.112.117515.
-
(2014)
J Nucl Med
-
-
Renaud, J.M.1
Mylonas, I.2
McArdle, B.3
Dowsley, T.4
Yip, K.5
Turcotte, E.6
-
38
-
-
70350652081
-
Prompt gamma correction for improved quantification in 82Rb PET
-
Watson C, Hayden C, Casey M, Hamill J, Bendriem B. Prompt gamma correction for improved quantification in 82Rb PET. Soc Nucl Med Annu Meet Abstr 2008;49:64P.
-
(2008)
Soc Nucl Med Annu Meet Abstr
, vol.49
, pp. 64P
-
-
Watson, C.1
Hayden, C.2
Casey, M.3
Hamill, J.4
Bendriem, B.5
-
39
-
-
0020193284
-
Estimation of the local statistical noise in emission computed tomography
-
COI: 1:STN:280:DC%2BD1c%2FotFaqtg%3D%3D, PID: 18238267
-
Alpert NM, Chesler D, Correia J, Ackerman RH, Chang JY, Finklestein S, et al. Estimation of the local statistical noise in emission computed tomography. IEEE Trans Med Imaging 1982;1:142-6. doi:10.1109/TMI.1982.4307561.
-
(1982)
IEEE Trans Med Imaging
, vol.1
, pp. 142-146
-
-
Alpert, N.M.1
Chesler, D.2
Correia, J.3
Ackerman, R.H.4
Chang, J.Y.5
Finklestein, S.6
-
40
-
-
0021151702
-
A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography
-
COI: 1:STN:280:DyaL2c3kvValsw%3D%3D, PID: 6610883
-
Huesman RH. A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography. Phys Med Biol 1984;29:543-52.
-
(1984)
Phys Med Biol
, vol.29
, pp. 543-552
-
-
Huesman, R.H.1
-
41
-
-
0027608825
-
An approximation formula for the variance of PET region-of-interest values
-
COI: 1:STN:280:DC%2BD1c%2FmsFemsA%3D%3D, PID: 18218411
-
Carson RE, Yan Y, Daube-Witherspoon ME, Freedman N, Bacharach SL, Herscovitch P. An approximation formula for the variance of PET region-of-interest values. IEEE Trans Med Imaging 1993;12:240-50.
-
(1993)
IEEE Trans Med Imaging
, vol.12
, pp. 240-250
-
-
Carson, R.E.1
Yan, Y.2
Daube-Witherspoon, M.E.3
Freedman, N.4
Bacharach, S.L.5
Herscovitch, P.6
-
42
-
-
58249094860
-
Accuracy of 3-dimensional reconstruction algorithms for the high-resolution research tomograph
-
PID: 19091902
-
Van Velden FHP, Kloet RW, van Berckel BNM, Lammertsma AA, Boellaard R. Accuracy of 3-dimensional reconstruction algorithms for the high-resolution research tomograph. J Nucl Med 2009;50:72-80. doi:10.2967/jnumed.108.052985.
-
(2009)
J Nucl Med
, vol.50
, pp. 72-80
-
-
Van Velden, F.H.P.1
Kloet, R.W.2
van Berckel, B.N.M.3
Lammertsma, A.A.4
Boellaard, R.5
-
43
-
-
34547807607
-
Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET
-
PID: 17631543
-
Chen GP, Branch KR, Alessio AM, Pham P, Tabibiazar R, Kinahan P, et al. Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET. J Nucl Med 2007;48:1259-65. doi:10.2967/jnumed.106.038232.
-
(2007)
J Nucl Med
, vol.48
, pp. 1259-1265
-
-
Chen, G.P.1
Branch, K.R.2
Alessio, A.M.3
Pham, P.4
Tabibiazar, R.5
Kinahan, P.6
-
44
-
-
33847131438
-
Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET
-
PID: 17033850
-
Søndergaard HM, Madsen MM, Boisen K, Bøttcher M, Schmitz O, Nielsen TT, et al. Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET. Eur J Nucl Med Mol Imaging 2007;34:320-9. doi:10.1007/s00259-006-0198-z.
-
(2007)
Eur J Nucl Med Mol Imaging
, vol.34
, pp. 320-329
-
-
Søndergaard, H.M.1
Madsen, M.M.2
Boisen, K.3
Bøttcher, M.4
Schmitz, O.5
Nielsen, T.T.6
-
45
-
-
84855186955
-
Appropriate parameters of the ordered-subset expectation maximization algorithm on measurement of myocardial blood flow and oxygen consumption with 11C-acetate PET
-
COI: 1:CAS:528:DC%2BC38XhtVeitrbF, PID: 22124363
-
Kobayashi M, Mori T, Kiyono Y, Tsujikawa T, Maruyama R, Higaki Y, et al. Appropriate parameters of the ordered-subset expectation maximization algorithm on measurement of myocardial blood flow and oxygen consumption with 11C-acetate PET. Nucl Med Commun 2012;33:130-8. doi:10.1097/MNM.0b013e32834e7f5c.
-
(2012)
Nucl Med Commun
, vol.33
, pp. 130-138
-
-
Kobayashi, M.1
Mori, T.2
Kiyono, Y.3
Tsujikawa, T.4
Maruyama, R.5
Higaki, Y.6
-
46
-
-
0035000317
-
Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: Quantitative characteristics and effects on kinetic modeling
-
COI: 1:STN:280:DC%2BD3MvkvVGgsQ%3D%3D, PID: 11337581
-
Boellaard R, van Lingen A, Lammertsma AA. Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: Quantitative characteristics and effects on kinetic modeling. J Nucl Med 2001;42:808-17.
-
(2001)
J Nucl Med
, vol.42
, pp. 808-817
-
-
Boellaard, R.1
van Lingen, A.2
Lammertsma, A.A.3
-
47
-
-
36148937522
-
Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies
-
PID: 17920931
-
Reilhac A, Tomeï S, Buvat I, Michel C, Keheren F, Costes N. Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies. NeuroImage 2008;39:359-68. doi:10.1016/j.neuroimage.2007.07.038.
-
(2008)
NeuroImage
, vol.39
, pp. 359-368
-
-
Reilhac, A.1
Tomeï, S.2
Buvat, I.3
Michel, C.4
Keheren, F.5
Costes, N.6
-
48
-
-
79551702064
-
Bias in iterative reconstruction of low-statistics PET data: Benefits of a resolution model
-
COI: 1:STN:280:DC%2BC3M7mtVyksA%3D%3D, PID: 21248391
-
Walker MD, Asselin M-C, Julyan PJ, Feldmann M, Talbot PS, Jones T, et al. Bias in iterative reconstruction of low-statistics PET data: Benefits of a resolution model. Phys Med Biol 2011;56:931. doi:10.1088/0031-9155/56/4/004.
-
(2011)
Phys Med Biol
, vol.56
, pp. 931
-
-
Walker, M.D.1
Asselin, M.-C.2
Julyan, P.J.3
Feldmann, M.4
Talbot, P.S.5
Jones, T.6
-
49
-
-
84904210630
-
IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). 2013. p. 1-4
-
Jian Y, Carson RE. Effect of subsets on bias and variance in low-count iterative PET reconstruction. In: 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). 2013. p. 1-4. doi:10.1109/NSSMIC.2013.6829220.
-
(2013)
doi:10.1109/NSSMIC.2013.6829220
-
-
Jian, Y.1
-
50
-
-
84925484476
-
Evaluation of image reconstruction algorithms encompassing time-of-flight and point spread function modelling for quantitative cardiac PET: Phantom studies
-
PID: 25367452
-
Presotto L, Gianolli L, Gilardi MC, Bettinardi V. Evaluation of image reconstruction algorithms encompassing time-of-flight and point spread function modelling for quantitative cardiac PET: Phantom studies. J Nucl Cardiol 2014. doi:10.1007/s12350-014-0023-1.
-
(2014)
J Nucl Cardiol
-
-
Presotto, L.1
Gianolli, L.2
Gilardi, M.C.3
Bettinardi, V.4
-
51
-
-
0021062116
-
Measurements of regional tissue and blood-pool radiotracer concentrations from serial tomographic images of the heart
-
COI: 1:CAS:528:DyaL2cXkslylsA%3D%3D, PID: 6605418
-
Henze E, Huang S-C, Ratib O, Hoffman E, Phelps ME, Schelbert HR. Measurements of regional tissue and blood-pool radiotracer concentrations from serial tomographic images of the heart. J Nucl Med 1983;24:987-96.
-
(1983)
J Nucl Med
, vol.24
, pp. 987-996
-
-
Henze, E.1
Huang, S.-C.2
Ratib, O.3
Hoffman, E.4
Phelps, M.E.5
Schelbert, H.R.6
-
52
-
-
84878952408
-
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
-
PID: 23718620
-
Rahmim A, Qi J, Sossi V. Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls. Med Phys 2013;40:064301. doi:10.1118/1.4800806.
-
(2013)
Med Phys
, vol.40
, pp. 064301
-
-
Rahmim, A.1
Qi, J.2
Sossi, V.3
-
53
-
-
67649213477
-
Performance characteristics of a New LSO PET/CT scanner with extended axial field-of-view and PSF reconstruction
-
Jakoby BW, Bercier Y, Watson CC, Bendriem B, Townsend DW. Performance characteristics of a New LSO PET/CT scanner with extended axial field-of-view and PSF reconstruction. IEEE Trans Nucl Sci 2009;56:633-9. doi:10.1109/TNS.2009.2015764.
-
(2009)
IEEE Trans Nucl Sci
, vol.56
, pp. 633-639
-
-
Jakoby, B.W.1
Bercier, Y.2
Watson, C.C.3
Bendriem, B.4
Townsend, D.W.5
-
54
-
-
80054055198
-
Properties and mitigation of edge artifacts in PSF-based PET reconstruction
-
Tong S, Alessio AM, Thielemans K, Stearns C, Ross S, Kinahan PE. Properties and mitigation of edge artifacts in PSF-based PET reconstruction. IEEE Trans Nucl Sci 2011;58:2264-75. doi:10.1109/TNS.2011.2164579.
-
(2011)
IEEE Trans Nucl Sci
, vol.58
, pp. 2264-2275
-
-
Tong, S.1
Alessio, A.M.2
Thielemans, K.3
Stearns, C.4
Ross, S.5
Kinahan, P.E.6
-
55
-
-
76849100926
-
Noise and signal properties in PSF-based fully 3D PET image reconstruction: An experimental evaluation
-
COI: 1:STN:280:DC%2BC3c7gslOnsw%3D%3D, PID: 20150683
-
Tong S, Alessio AM, Kinahan PE. Noise and signal properties in PSF-based fully 3D PET image reconstruction: An experimental evaluation. Phys Med Biol 2010;55:1453. doi:10.1088/0031-9155/55/5/013.
-
(2010)
Phys Med Biol
, vol.55
, pp. 1453
-
-
Tong, S.1
Alessio, A.M.2
Kinahan, P.E.3
-
56
-
-
0019572508
-
A mathematical model for positron-emission tomography systems having time-of-flight measurements
-
Snyder DL, Thomas LJ, Ter-Pogossian MM. A mathematical model for positron-emission tomography systems having time-of-flight measurements. IEEE Trans Nucl Sci 1981;28:3575-83. doi:10.1109/TNS.1981.4332168.
-
(1981)
IEEE Trans Nucl Sci
, vol.28
, pp. 3575-3583
-
-
Snyder, D.L.1
Thomas, L.J.2
Ter-Pogossian, M.M.3
-
57
-
-
0020701632
-
Time-of-flight positron emission tomography: Status relative to conventional PET
-
COI: 1:CAS:528:DyaL3sXmsl2mtw%3D%3D, PID: 6336778
-
Budinger TF. Time-of-flight positron emission tomography: Status relative to conventional PET. J Nucl Med 1983;24:73-8.
-
(1983)
J Nucl Med
, vol.24
, pp. 73-78
-
-
Budinger, T.F.1
-
59
-
-
84901360088
-
Determination of accuracy and precision of lesion uptake measurements in human subjects with time-of-flight PET
-
PID: 24604909
-
Daube-Witherspoon ME, Surti S, Perkins AE, Karp JS. Determination of accuracy and precision of lesion uptake measurements in human subjects with time-of-flight PET. J Nucl Med 2014;55:602-7. doi:10.2967/jnumed.113.127035.
-
(2014)
J Nucl Med
, vol.55
, pp. 602-607
-
-
Daube-Witherspoon, M.E.1
Surti, S.2
Perkins, A.E.3
Karp, J.S.4
-
60
-
-
84867886338
-
Signal-to-noise gain at variable randoms ratio in TOF PET
-
Mettivier G, Tabacchini V, Conti M, Russo P. Signal-to-noise gain at variable randoms ratio in TOF PET. IEEE Trans Nucl Sci 2012;59:1948-57. doi:10.1109/TNS.2012.2198833.
-
(2012)
IEEE Trans Nucl Sci
, vol.59
, pp. 1948-1957
-
-
Mettivier, G.1
Tabacchini, V.2
Conti, M.3
Russo, P.4
-
61
-
-
84988329781
-
Advantages of improved time resolution for TOF PET at very low statistics
-
Westerwoudt V, Conti M, Eriksson L. Advantages of improved time resolution for TOF PET at very low statistics. IEEE Trans Nucl Sci 2014;61:126-33. doi:10.1109/TNS.2013.2287175.
-
(2014)
IEEE Trans Nucl Sci
, vol.61
, pp. 126-133
-
-
Westerwoudt, V.1
Conti, M.2
Eriksson, L.3
-
62
-
-
33646388372
-
Investigation of time-of-flight benefit for fully 3-D PET
-
PID: 16689258
-
Surti S, Karp JS, Popescu LM, Daube-Witherspoon ME, Werner M. Investigation of time-of-flight benefit for fully 3-D PET. IEEE Trans Med Imaging 2006;25:529-38. doi:10.1109/TMI.2006.871419.
-
(2006)
IEEE Trans Med Imaging
, vol.25
, pp. 529-538
-
-
Surti, S.1
Karp, J.S.2
Popescu, L.M.3
Daube-Witherspoon, M.E.4
Werner, M.5
-
63
-
-
79551660998
-
Why is TOF PET reconstruction a more robust method in the presence of inconsistent data?
-
PID: 21119224
-
Conti M. Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? Phys Med Biol 2011;56:155. doi:10.1088/0031-9155/56/1/010.
-
(2011)
Phys Med Biol
, vol.56
, pp. 155
-
-
Conti, M.1
-
64
-
-
84881562753
-
Performance evaluation of a prototype Positron Emission Tomography scanner using Digital Photon Counters (DPC)
-
2820-4
-
Degenhardt C, Rodrigues P, Trindade A, Zwaans B, Mulhens O, Dorscheid R, et al. Performance evaluation of a prototype Positron Emission Tomography scanner using Digital Photon Counters (DPC). In: 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). 2012:2820-4. doi:10.1109/NSSMIC.2012.6551643.
-
(2012)
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
-
-
Degenhardt, C.1
Rodrigues, P.2
Trindade, A.3
Zwaans, B.4
Mulhens, O.5
Dorscheid, R.6
-
65
-
-
84881581082
-
Evaluation of time of flight (TOF) and point spread function (PSF) reconstructions in the quantification of myocardial blood flow with 13N ammonia and PET: Comparison among reconstructions (reprojection, OSEM), software (PMOD and CARIMAS) and operators
-
3979-82
-
Presotto L, Busnardo E, Bettinardi V, Landoni C, Todeschini P, Rimoldi O, et al. Evaluation of time of flight (TOF) and point spread function (PSF) reconstructions in the quantification of myocardial blood flow with 13N ammonia and PET: Comparison among reconstructions (reprojection, OSEM), software (PMOD and CARIMAS) and operators. In: 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). 2012:3979-82. doi:10.1109/NSSMIC.2012.6551912.
-
(2012)
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
-
-
Presotto, L.1
Busnardo, E.2
Bettinardi, V.3
Landoni, C.4
Todeschini, P.5
Rimoldi, O.6
-
66
-
-
84901652196
-
Impact of point spread function modeling and time-of-flight on myocardial blood flow and myocardial flow reserve measurements for rubidium-82 cardiac PET
-
PID: 24477406
-
Armstrong IS, Tonge CM, Arumugam P. Impact of point spread function modeling and time-of-flight on myocardial blood flow and myocardial flow reserve measurements for rubidium-82 cardiac PET. J Nucl Cardiol 2014;21:467-74. doi:10.1007/s12350-014-9858-8.
-
(2014)
J Nucl Cardiol
, vol.21
, pp. 467-474
-
-
Armstrong, I.S.1
Tonge, C.M.2
Arumugam, P.3
-
67
-
-
84942296357
-
Impact of time-of-flight on qualitative and quantitative analyses of myocardial perfusion PET studies using 13N-ammonia
-
PID: 25467250
-
Tomiyama T, Ishihara K, Suda M, Kanaya K, Sakurai M, Takahashi N, et al. Impact of time-of-flight on qualitative and quantitative analyses of myocardial perfusion PET studies using 13N-ammonia. J Nucl Cardiol 2014. doi:10.1007/s12350-014-0037-8.
-
(2014)
J Nucl Cardiol.
-
-
Tomiyama, T.1
Ishihara, K.2
Suda, M.3
Kanaya, K.4
Sakurai, M.5
Takahashi, N.6
-
68
-
-
34249701087
-
Quantification of myocardial blood flow with 82Rb dynamic PET imaging
-
PID: 17619189
-
Lortie M, Beanlands RSB, Yoshinaga K, Klein R, Dasilva JN, DeKemp RA. Quantification of myocardial blood flow with 82Rb dynamic PET imaging. Eur J Nucl Med Mol Imaging 2007;34:1765-74.
-
(2007)
Eur J Nucl Med Mol Imaging
, vol.34
, pp. 1765-1774
-
-
Lortie, M.1
Beanlands, R.S.B.2
Yoshinaga, K.3
Klein, R.4
Dasilva, J.N.5
DeKemp, R.A.6
-
69
-
-
84942258609
-
Cardiac positron emission tomography: Overview of myocardial perfusion, myocardial blood flow and myocardial flow reserve imaging
-
Pan X-B, Declerck J, Burckhardt DD. Cardiac positron emission tomography: Overview of myocardial perfusion, myocardial blood flow and myocardial flow reserve imaging. Siemens Medical Solutions; 2011:1-24.
-
(2011)
Siemens Medical Solutions
, pp. 1-24
-
-
Pan, X.-B.1
Declerck, J.2
Burckhardt, D.D.3
-
70
-
-
84942260534
-
Effects of filtering on Rb-82 myocardial blood flow estimates
-
54:1659
-
Lee B, Moody J, Sitek A, Murthy V, Di Carli M, Corbett J, et al. Effects of filtering on Rb-82 myocardial blood flow estimates. In: Society of Nuclear Medicine Annual Meeting Abstracts. 2013;54:1659. http://jnumedmtg.snmjournals.org.
-
(2013)
Society of Nuclear Medicine Annual Meeting Abstracts
-
-
Lee, B.1
Moody, J.2
Sitek, A.3
Murthy, V.4
Di Carli, M.5
Corbett, J.6
-
71
-
-
84881578852
-
IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). 2012:2638-42
-
Presotto L, Bettinardi V, Petta P, Gilardi MC. A compact dynamic phantom to assess the effect of motion in cardiac PET and SPECT studies. In: 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). 2012:2638-42. doi:10.1109/NSSMIC.2012.6551601.
-
(2012)
doi:10.1109/NSSMIC.2012.6551601
-
-
Presotto, L.1
Bettinardi, V.2
Petta, P.3
-
72
-
-
0026710876
-
A region of interest strategy for minimizing resolution distortions in quantitative myocardial PET studies
-
COI: 1:STN:280:DyaK383osVeisg%3D%3D, PID: 1597746
-
Hutchins GD, Caraher JM, Raylman RR. A region of interest strategy for minimizing resolution distortions in quantitative myocardial PET studies. J Nucl Med 1992;33:1243-50.
-
(1992)
J Nucl Med
, vol.33
, pp. 1243-1250
-
-
Hutchins, G.D.1
Caraher, J.M.2
Raylman, R.R.3
-
73
-
-
40549132872
-
Combined imaging of molecular function and morphology with PET/CT and SPECT/CT: Image fusion and motion correction
-
PID: 18324375
-
Schäfers KP, Stegger L. Combined imaging of molecular function and morphology with PET/CT and SPECT/CT: Image fusion and motion correction. Basic Res Cardiol 2008;103:191-9. doi:10.1007/s00395-008-0717-0.
-
(2008)
Basic Res Cardiol
, vol.103
, pp. 191-199
-
-
Schäfers, K.P.1
Stegger, L.2
-
74
-
-
84881572986
-
Generalized dynamic PET inter-frame and intra-frame motion correction: Phantom and human validation studies
-
3067-78
-
Mohy-ud-Din H, Karakatsanis NA, Goddard JS, Baba J, Wills W, Tahari AK, et al. Generalized dynamic PET inter-frame and intra-frame motion correction: Phantom and human validation studies. In: 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). 2012:3067-78. doi:10.1109/NSSMIC.2012.6551701.
-
(2012)
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
-
-
-
75
-
-
84873572898
-
Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging
-
PID: 23387770
-
Pourmoghaddas A, Klein R, deKemp RA, Wells RG. Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging. Med Phys 2013;40:022503. doi:10.1118/1.4788669.
-
(2013)
Med Phys
, vol.40
, pp. 022503
-
-
Pourmoghaddas, A.1
Klein, R.2
deKemp, R.A.3
Wells, R.G.4
-
76
-
-
84905567619
-
Extracting a respiratory signal from raw dynamic PET data that contain tracer kinetics
-
COI: 1:STN:280:DC%2BC2cbivFGgsw%3D%3D, PID: 25031067
-
Schleyer PJ, Thielemans K, Marsden PK. Extracting a respiratory signal from raw dynamic PET data that contain tracer kinetics. Phys Med Biol 2014;59:4345. doi:10.1088/0031-9155/59/15/4345.
-
(2014)
Phys Med Biol
, vol.59
, pp. 4345
-
-
Schleyer, P.J.1
Thielemans, K.2
Marsden, P.K.3
-
77
-
-
84856853168
-
Time-of-flight PET data determine the attenuation sinogram up to a constant
-
PID: 22290428
-
Defrise M, Rezaei A, Nuyts J. Time-of-flight PET data determine the attenuation sinogram up to a constant. Phys Med Biol 2012;57:885. doi:10.1088/0031-9155/57/4/885.
-
(2012)
Phys Med Biol
, vol.57
, pp. 885
-
-
Defrise, M.1
Rezaei, A.2
Nuyts, J.3
-
79
-
-
0021998326
-
Quantification of rotational thallium-201 myocardial tomography
-
COI: 1:STN:280:DyaL2M%2Fot1eisQ%3D%3D, PID: 3871228
-
Garcia EV, Van Train K, Maddahi J, Prigent F, Friedman J, Areeda J, et al. Quantification of rotational thallium-201 myocardial tomography. J Nucl Med 1985;26:17-26.
-
(1985)
J Nucl Med
, vol.26
, pp. 17-26
-
-
Garcia, E.V.1
Van Train, K.2
Maddahi, J.3
Prigent, F.4
Friedman, J.5
Areeda, J.6
-
80
-
-
0023839234
-
Validation of PET-acquired input functions for cardiac studies
-
COI: 1:STN:280:DyaL1c7lsFSgtQ%3D%3D, PID: 3258026
-
Weinberg IN, Huang SC, Hoffman EJ, Araujo L, Nienaber C, McKay MG, et al. Validation of PET-acquired input functions for cardiac studies. J Nucl Med 1988;29:241-7.
-
(1988)
J Nucl Med
, vol.29
, pp. 241-247
-
-
Weinberg, I.N.1
Huang, S.C.2
Hoffman, E.J.3
Araujo, L.4
Nienaber, C.5
McKay, M.G.6
-
81
-
-
77956539101
-
Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 PET and a highly automated analysis program
-
PID: 20387135
-
Klein R, Renaud JM, Ziadi MC, Thorn SL, Adler A, Beanlands RS, et al. Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 PET and a highly automated analysis program. J Nucl Cardiol 2010;17:600-16. doi:10.1007/s12350-010-9225-3.
-
(2010)
J Nucl Cardiol
, vol.17
, pp. 600-616
-
-
Klein, R.1
Renaud, J.M.2
Ziadi, M.C.3
Thorn, S.L.4
Adler, A.5
Beanlands, R.S.6
-
82
-
-
0018367149
-
Quantitation in positron emission computed tomography: 1. Effect of object size
-
COI: 1:STN:280:DyaE1M7ntlGhtQ%3D%3D, PID: 438372
-
Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr 1979;3:299-308. doi:10.1097/00004728-197906000-00001
-
(1979)
J Comput Assist Tomogr
, vol.3
, pp. 299-308
-
-
Hoffman, E.J.1
Huang, S.C.2
Phelps, M.E.3
-
83
-
-
0030136750
-
Three-dimensional correction for spillover and recovery of myocardial PET images
-
COI: 1:STN:280:DyaK283itFWrsw%3D%3D, PID: 8965143
-
Nuyts J, Maes A, Vrolix M, Schiepers C, Schelbert H, Kuhle W, et al. Three-dimensional correction for spillover and recovery of myocardial PET images. J Nucl Med 1996;37:767-74.
-
(1996)
J Nucl Med
, vol.37
, pp. 767-774
-
-
Nuyts, J.1
Maes, A.2
Vrolix, M.3
Schiepers, C.4
Schelbert, H.5
Kuhle, W.6
-
84
-
-
0028896734
-
Variability and reproducibility of rubidium-82 kinetic parameters in the myocardium of the anesthetized canine
-
COI: 1:CAS:528:DyaK2MXltlCmsb8%3D, PID: 7830133
-
Coxson PG, Brennan KM, Huesman RH, Lim S, Budinger TF. Variability and reproducibility of rubidium-82 kinetic parameters in the myocardium of the anesthetized canine. J Nucl Med 1995;36:287-96.
-
(1995)
J Nucl Med
, vol.36
, pp. 287-296
-
-
Coxson, P.G.1
Brennan, K.M.2
Huesman, R.H.3
Lim, S.4
Budinger, T.F.5
-
85
-
-
84875761035
-
Multisoftware reproducibility study of stress and rest myocardial blood flow assessed with 3D dynamic PET/CT and a 1-tissue-compartment model of 82Rb kinetics
-
COI: 1:CAS:528:DC%2BC3sXms1Ggsrs%3D, PID: 23447656
-
deKemp RA, Declerck J, Klein R, Pan X-B, Nakazato R, Tonge C, et al. Multisoftware reproducibility study of stress and rest myocardial blood flow assessed with 3D dynamic PET/CT and a 1-tissue-compartment model of 82Rb kinetics. J Nucl Med 2013;54:571-7.
-
(2013)
J Nucl Med
, vol.54
, pp. 571-577
-
-
deKemp, R.A.1
Declerck, J.2
Klein, R.3
Pan, X.-B.4
Nakazato, R.5
Tonge, C.6
-
86
-
-
0036489379
-
Correction for ambiguous solutions in factor analysis using a penalized least squares objective
-
PID: 11989846
-
Sitek A, Gullberg GT, Huesman RH. Correction for ambiguous solutions in factor analysis using a penalized least squares objective. IEEE Trans Med Imaging 2002;21:216-25.
-
(2002)
IEEE Trans Med Imaging
, vol.21
, pp. 216-225
-
-
Sitek, A.1
Gullberg, G.T.2
Huesman, R.H.3
-
87
-
-
25444484119
-
Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses
-
PID: 16085581
-
El Fakhri G, Sitek A, Guerin B, Kijewski MF, Di Carli MF, Moore SC. Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses. J Nucl Med 2005;46:1264-71.
-
(2005)
J Nucl Med
, vol.46
, pp. 1264-1271
-
-
El Fakhri, G.1
Sitek, A.2
Guerin, B.3
Kijewski, M.F.4
Di Carli, M.F.5
Moore, S.C.6
-
88
-
-
67650035154
-
Reproducibility and accuracy of quantitative myocardial blood flow assessment with 82Rb PET: Comparison with 13N-ammonia PET
-
PID: 19525467
-
El Fakhri G, Kardan A, Sitek A, Dorbala S, Abi-Hatem N, Lahoud Y, et al. Reproducibility and accuracy of quantitative myocardial blood flow assessment with 82Rb PET: Comparison with 13N-ammonia PET. J Nucl Med 2009;50:1062-71. doi:10.2967/jnumed.104.007831.
-
(2009)
J Nucl Med
, vol.50
, pp. 1062-1071
-
-
El Fakhri, G.1
Kardan, A.2
Sitek, A.3
Dorbala, S.4
Abi-Hatem, N.5
Lahoud, Y.6
-
89
-
-
78149481478
-
Kinetic model-based factor analysis of dynamic sequences for 82-rubidium cardiac positron emission tomography
-
COI: 1:CAS:528:DC%2BC3cXps1alu7o%3D, PID: 20879561
-
Klein R, Beanlands RS, Wassenaar RW, Thorn SL, Lamoureux M, DaSilva JN, et al. Kinetic model-based factor analysis of dynamic sequences for 82-rubidium cardiac positron emission tomography. Med Phys 2010;37:3995-4010.
-
(2010)
Med Phys
, vol.37
, pp. 3995-4010
-
-
Klein, R.1
Beanlands, R.S.2
Wassenaar, R.W.3
Thorn, S.L.4
Lamoureux, M.5
DaSilva, J.N.6
-
90
-
-
84915815348
-
Comparison and prognostic validation of multiple methods of quantification of myocardial blood flow with 82Rb PET
-
COI: 1:CAS:528:DC%2BC2MXislegsw%3D%3D, PID: 25429160
-
Murthy VL, Lee BC, Sitek A, Naya M, Moody J, Polavarapu V, et al. Comparison and prognostic validation of multiple methods of quantification of myocardial blood flow with 82Rb PET. J Nucl Med 2014;55:1952-8. doi:10.2967/jnumed.114.145342.
-
(2014)
J Nucl Med
, vol.55
, pp. 1952-1958
-
-
Murthy, V.L.1
Lee, B.C.2
Sitek, A.3
Naya, M.4
Moody, J.5
Polavarapu, V.6
-
91
-
-
84942240477
-
Generation of parametric images from time-of-flight 82Rb and 15O-water cardiac PET with ICA-derived input functions
-
Germino M, Ropchan J, Mulnix T, Najafzadeh S, Ackah E, Feringa H, et al. Generation of parametric images from time-of-flight 82Rb and 15O-water cardiac PET with ICA-derived input functions. Soc Nucl Med Annu Meet Abstr 2014;55:46.
-
(2014)
Soc Nucl Med Annu Meet Abstr
, vol.55
, pp. 46
-
-
Germino, M.1
Ropchan, J.2
Mulnix, T.3
Najafzadeh, S.4
Ackah, E.5
Feringa, H.6
-
92
-
-
0030941496
-
Consequences of using a simplified kinetic model for dynamic PET data
-
COI: 1:STN:280:DyaK2s3lt1OlsQ%3D%3D, PID: 9098221
-
Coxson PG, Huesman RH, Borland L. Consequences of using a simplified kinetic model for dynamic PET data. J Nucl Med 1997;38:660-7.
-
(1997)
J Nucl Med
, vol.38
, pp. 660-667
-
-
Coxson, P.G.1
Huesman, R.H.2
Borland, L.3
-
93
-
-
0034894418
-
[1-11C]Acetate as a quantitative perfusion tracer in myocardial PET
-
PID: 11483676
-
Van den Hoff J, Burchert W, Borner A-R, Fricke H, Kuhnel G, Meyer GJ, et al. [1-11C]Acetate as a quantitative perfusion tracer in myocardial PET. J Nucl Med 2001;42:1174-82.
-
(2001)
J Nucl Med
, vol.42
, pp. 1174-1182
-
-
Van den Hoff, J.1
Burchert, W.2
Borner, A.-R.3
Fricke, H.4
Kuhnel, G.5
Meyer, G.J.6
-
94
-
-
84862686055
-
Quantification of myocardial blood flow with 82Rb positron emission tomography: Clinical validation with 15O-water
-
PID: 22398957
-
Prior JO, Allenbach G, Valenta I, Kosinski M, Burger C, Verdun FR, et al. Quantification of myocardial blood flow with 82Rb positron emission tomography: Clinical validation with 15O-water. Eur J Nucl Med Mol Imaging 2012;39:1037-47.
-
(2012)
Eur J Nucl Med Mol Imaging
, vol.39
, pp. 1037-1047
-
-
Prior, J.O.1
Allenbach, G.2
Valenta, I.3
Kosinski, M.4
Burger, C.5
Verdun, F.R.6
-
95
-
-
0021043561
-
Myocardial perfusion with rubidium-82. II. Effects of metabolic and pharmacologic interventions
-
COI: 1:CAS:528:DyaL3sXlslajurw%3D, PID: 6619961
-
Goldstein RA, Mullani NA, Marani SK, Fisher DJ, Gould KL, O’Brien HA. Myocardial perfusion with rubidium-82. II. Effects of metabolic and pharmacologic interventions. J Nucl Med 1983;24:907-15.
-
(1983)
J Nucl Med
, vol.24
, pp. 907-915
-
-
Goldstein, R.A.1
Mullani, N.A.2
Marani, S.K.3
Fisher, D.J.4
Gould, K.L.5
O’Brien, H.A.6
-
96
-
-
0021084091
-
Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors
-
COI: 1:CAS:528:DyaL3sXlslajur8%3D, PID: 6619960
-
Mullani NA, Goldstein RA, Gould KL, Marani SK, Fisher DJ, O’Brien HA, et al. Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors. J Nucl Med 1983;24:898-906.
-
(1983)
J Nucl Med
, vol.24
, pp. 898-906
-
-
Mullani, N.A.1
Goldstein, R.A.2
Gould, K.L.3
Marani, S.K.4
Fisher, D.J.5
O’Brien, H.A.6
-
97
-
-
0025542036
-
Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model
-
COI: 1:STN:280:DyaK3czotFyqtA%3D%3D, PID: 2401071
-
Herrero P, Markham J, Shelton ME, Weinheimer CJ, Bergmann SR. Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model. Circulation 1990;82:1377-86.
-
(1990)
Circulation
, vol.82
, pp. 1377-1386
-
-
Herrero, P.1
Markham, J.2
Shelton, M.E.3
Weinheimer, C.J.4
Bergmann, S.R.5
-
98
-
-
0026536640
-
Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography
-
COI: 1:CAS:528:DyaK38XhvFSgsrY%3D, PID: 1537087
-
Herrero P, Markham J, Shelton M, Bergmann S. Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography. Circ Res 1992;70:496-507.
-
(1992)
Circ Res
, vol.70
, pp. 496-507
-
-
Herrero, P.1
Markham, J.2
Shelton, M.3
Bergmann, S.4
-
99
-
-
0029815801
-
Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia
-
COI: 1:STN:280:DyaK2s%2FhsFKlug%3D%3D, PID: 8862316
-
Yoshida K, Mullani N, Gould KL. Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia. J Nucl Med 1996;37:1701-12.
-
(1996)
J Nucl Med
, vol.37
, pp. 1701-1712
-
-
Yoshida, K.1
Mullani, N.2
Gould, K.L.3
-
100
-
-
84867492397
-
Quantification of cerebral blood flow
-
Gründer G, (ed), Neuromethods, Humana Press, New York
-
Lammertsma AA. Quantification of cerebral blood flow. In: Gründer G, editor. Molecular Imaging in the Clinical Neurosciences. Neuromethods. New York: Humana Press; 2012. p. 99-109. doi:10.1007/7657_2012_43.
-
(2012)
Molecular Imaging in the Clinical Neurosciences
, pp. 99-109
-
-
Lammertsma, A.A.1
-
101
-
-
0026081779
-
The precision of positron emission tomography: Theory and measurement
-
COI: 1:STN:280:DyaK3M7kslCmsg%3D%3D, PID: 1997483
-
Alpert NM, Barker WC, Gelman A, Weise S, Senda M, Correia JA. The precision of positron emission tomography: Theory and measurement. J Cereb Blood Flow Metab 1991;11:A26-30. doi:10.1038/jcbfm.1991.33.
-
(1991)
J Cereb Blood Flow Metab
, vol.11
, pp. A26-A30
-
-
Alpert, N.M.1
Barker, W.C.2
Gelman, A.3
Weise, S.4
Senda, M.5
Correia, J.A.6
-
102
-
-
0030109465
-
Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography
-
COI: 1:STN:280:DC%2BD1c7is1WmsQ%3D%3D, PID: 18285134
-
Fessler JA. Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography. IEEE Trans Image Process 1996;5:493-506.
-
(1996)
IEEE Trans Image Process
, vol.5
, pp. 493-506
-
-
Fessler, J.A.1
-
103
-
-
0242606146
-
A unified noise analysis for iterative image estimation
-
PID: 14653559
-
Qi J. A unified noise analysis for iterative image estimation. Phys Med Biol 2003;48:3505-19. doi:10.1088/0031-9155/48/21/004.
-
(2003)
Phys Med Biol
, vol.48
, pp. 3505-3519
-
-
Qi, J.1
-
104
-
-
33646419785
-
Theoretical study of penalized-likelihood image reconstruction for region of interest quantification
-
COI: 1:CAS:528:DC%2BD1cXjvFGgt7o%3D, PID: 16689267
-
Qi J, Huesman H. Theoretical study of penalized-likelihood image reconstruction for region of interest quantification. IEEE Trans Med Imaging 2006;25:640-8. doi:10.1109/TMI.2006.873223.
-
(2006)
IEEE Trans Med Imaging
, vol.25
, pp. 640-648
-
-
Qi, J.1
Huesman, H.2
-
105
-
-
33747584180
-
Optimization algorithms and weighting factors for analysis of dynamic PET studies
-
PID: 16912378
-
Yaqub M, Boellaard R, Kropholler MA, Lammertsma AA. Optimization algorithms and weighting factors for analysis of dynamic PET studies. Phys Med Biol 2006;51:4217. doi:10.1088/0031-9155/51/17/007.
-
(2006)
Phys Med Biol
, vol.51
, pp. 4217
-
-
Yaqub, M.1
Boellaard, R.2
Kropholler, M.A.3
Lammertsma, A.A.4
-
106
-
-
62149148841
-
Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: Validation in a canine model of coronary artery stenosis
-
PID: 18985343
-
Lautamäki R, George R, Kitagawa K, Higuchi T, Merrill J, Voicu C, et al. Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: Validation in a canine model of coronary artery stenosis. Eur J Nucl Med Mol Imaging 2009;36:576-86.
-
(2009)
Eur J Nucl Med Mol Imaging
, vol.36
, pp. 576-586
-
-
Lautamäki, R.1
George, R.2
Kitagawa, K.3
Higuchi, T.4
Merrill, J.5
Voicu, C.6
-
107
-
-
80052810377
-
Physiological basis for angina and ST-segment change: PET-verified thresholds of quantitative stress myocardial perfusion and coronary flow reserve
-
PID: 21920337
-
Johnson NP, Gould KL. Physiological basis for angina and ST-segment change: PET-verified thresholds of quantitative stress myocardial perfusion and coronary flow reserve. JACC Cardiovasc Imaging 2011;4:990-8. doi:10.1016/j.jcmg.2011.06.015.
-
(2011)
JACC Cardiovasc Imaging
, vol.4
, pp. 990-998
-
-
Johnson, N.P.1
Gould, K.L.2
-
108
-
-
84859589063
-
Integrating noninvasive absolute flow, coronary flow reserve, and ischemic thresholds into a comprehensive map of physiological severity
-
PID: 22498334
-
Johnson NP, Gould KL. Integrating noninvasive absolute flow, coronary flow reserve, and ischemic thresholds into a comprehensive map of physiological severity. JACC Cardiovasc Imaging 2012;5:430-40. doi:10.1016/j.jcmg.2011.12.014.
-
(2012)
JACC Cardiovasc Imaging
, vol.5
, pp. 430-440
-
-
Johnson, N.P.1
Gould, K.L.2
-
110
-
-
0021915795
-
Performance comparison of parameter estimation techniques for the quantitation of local cerebral blood flow by dynamic positron computed tomography
-
COI: 1:STN:280:DyaL2M7ot12jtA%3D%3D, PID: 3872874
-
Koeppe RA, Holden JE, Ip WR. Performance comparison of parameter estimation techniques for the quantitation of local cerebral blood flow by dynamic positron computed tomography. J Cereb Blood Flow Metab 1985;5:224-34. doi:10.1038/jcbfm.1985.29.
-
(1985)
J Cereb Blood Flow Metab
, vol.5
, pp. 224-234
-
-
Koeppe, R.A.1
Holden, J.E.2
Ip, W.R.3
-
111
-
-
84880196994
-
Generalized separable parameter space techniques for fitting 1K-5K serial compartment models
-
PID: 23822451
-
Kadrmas DJ, Oktay MB. Generalized separable parameter space techniques for fitting 1K-5K serial compartment models. Med Phys 2013;40:072502. doi:10.1118/1.4810937.
-
(2013)
Med Phys
, vol.40
, pp. 072502
-
-
Kadrmas, D.J.1
Oktay, M.B.2
-
113
-
-
84868213305
-
PET: Is myocardial flow quantification a clinical reality?
-
PID: 22733534
-
Saraste A, Kajander S, Han C, Nesterov SV, Knuuti J. PET: Is myocardial flow quantification a clinical reality? J Nucl Cardiol 2012;19:1044-59.
-
(2012)
J Nucl Cardiol
, vol.19
, pp. 1044-1059
-
-
Saraste, A.1
Kajander, S.2
Han, C.3
Nesterov, S.V.4
Knuuti, J.5
-
114
-
-
84942260538
-
-
Accessed December 1, 2014
-
Positron Corporation. Integrating the Cardiac PET Supply Chain. 2014. http://www.positron.com/attrius. Accessed December 1, 2014.
-
(2014)
Integrating the Cardiac PET Supply Chain
-
-
-
115
-
-
84942260539
-
-
Accessed December 1, 2014
-
INVIA Medical Imaging Solutions. Corridor4DM CFR. 2014. http://www.inviasolutions.com/corridor4dm. Accessed December 1, 2014.
-
(2014)
Corridor4DM CFR
-
-
-
116
-
-
84942260540
-
-
Accessed December 1, 2014
-
Cardiovascular Imaging Technologies. ImagenQ: Absolute PET Quantification of cardiac PET. 2014. http://www.cvit.com/products/imagenq/. Accessed December 1, 2014.
-
(2014)
ImagenQ: Absolute PET Quantification of cardiac PET
-
-
-
117
-
-
84942260541
-
-
Accessed December 1, 2014
-
Cedars-Sinai. Quantitative PET (QPET). 2014. http://cedars-sinai.edu/Patients/Programs-and-Services/Medicine-Department/Artificial-Intelligence-in-Medicine-AIM/Projects/Quantitative-PET-QPET.aspx. Accessed December 1, 2014.
-
(2014)
-
-
-
119
-
-
84856803974
-
Comparison of clinical tools for measurements of regional stress and rest myocardial blood flow assessed with 13N-ammonia PET/CT
-
COI: 1:CAS:528:DC%2BC38XjsVSlt7k%3D, PID: 22228795
-
Slomka PJ, Alexanderson E, Jácome R, Jiménez M, Romero E, Meave A, et al. Comparison of clinical tools for measurements of regional stress and rest myocardial blood flow assessed with 13N-ammonia PET/CT. J Nucl Med 2012;53:171-81. doi:10.2967/jnumed.111.095398.
-
(2012)
J Nucl Med
, vol.53
, pp. 171-181
-
-
Slomka, P.J.1
Alexanderson, E.2
Jácome, R.3
Jiménez, M.4
Romero, E.5
Meave, A.6
-
120
-
-
84890806759
-
Absolute myocardial flow quantification with 82Rb PET/CT: Comparison of different software packages and methods
-
PID: 23982454
-
Tahari AK, Lee A, Rajaram M, Fukushima K, Lodge MA, Lee BC, et al. Absolute myocardial flow quantification with 82Rb PET/CT: Comparison of different software packages and methods. Eur J Nucl Med Mol Imaging 2014;41:126-35.
-
(2014)
Eur J Nucl Med Mol Imaging
, vol.41
, pp. 126-135
-
-
Tahari, A.K.1
Lee, A.2
Rajaram, M.3
Fukushima, K.4
Lodge, M.A.5
Lee, B.C.6
-
121
-
-
84937763098
-
Dependency of cardiac rubidium-82 imaging quantitative measures on age, gender, vascular territory, and software in a cardiovascular normal population
-
PID: 25294436
-
Sunderland JJ, Pan X-B, Declerck J, Menda Y. Dependency of cardiac rubidium-82 imaging quantitative measures on age, gender, vascular territory, and software in a cardiovascular normal population. J Nucl Cardiol 2015;22:72–84. doi:10.1007/s12350-014-9920-6.
-
(2015)
J Nucl Cardiol
, vol.22
, pp. 72-84
-
-
Sunderland, J.J.1
Pan, X.-B.2
Declerck, J.3
Menda, Y.4
-
122
-
-
84922560700
-
Quantification of myocardial blood flow in absolute terms using 82Rb PET imaging: Results of RUBY-10 study
-
PID: 25306543
-
Nesterov SV, Deshayes E, Sciagrà R, Settimo L, Declerck JM, Pan X-B, et al. Quantification of myocardial blood flow in absolute terms using 82Rb PET imaging: Results of RUBY-10 study. JACC Cardiovasc Imaging 2014. doi:10.1016/j.jcmg.2014.08.003.
-
(2014)
JACC Cardiovasc Imaging
-
-
Nesterov, S.V.1
Deshayes, E.2
Sciagrà, R.3
Settimo, L.4
Declerck, J.M.5
Pan, X.-B.6
-
123
-
-
58249120511
-
Repeatability of rest and hyperemic myocardial blood flow measurements with 82Rb dynamic PET
-
PID: 19091892
-
Manabe O, Yoshinaga K, Katoh C, Naya M, Kemp RA, Tamaki N. Repeatability of rest and hyperemic myocardial blood flow measurements with 82Rb dynamic PET. J Nucl Med 2009;50:68-71.
-
(2009)
J Nucl Med
, vol.50
, pp. 68-71
-
-
Manabe, O.1
Yoshinaga, K.2
Katoh, C.3
Naya, M.4
Kemp, R.A.5
Tamaki, N.6
-
124
-
-
84868206451
-
Short-term repeatability of resting myocardial blood flow measurements using rubidium-82 PET imaging
-
PID: 22826134
-
Efseaff M, Klein R, Ziadi MC, Beanlands RS, deKemp RA. Short-term repeatability of resting myocardial blood flow measurements using rubidium-82 PET imaging. J Nucl Cardiol 2012;19:997-1006.
-
(2012)
J Nucl Cardiol
, vol.19
, pp. 997-1006
-
-
Efseaff, M.1
Klein, R.2
Ziadi, M.C.3
Beanlands, R.S.4
deKemp, R.A.5
-
125
-
-
79955777624
-
Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82Rb PET perfusion imaging
-
PID: 21498538
-
Fukushima K, Javadi MS, Higuchi T, Lautamäki R, Merrill J, Nekolla SG, et al. Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82Rb PET perfusion imaging. J Nucl Med 2011;52:726-32. doi:10.2967/jnumed.110.081828.
-
(2011)
J Nucl Med
, vol.52
, pp. 726-732
-
-
Fukushima, K.1
Javadi, M.S.2
Higuchi, T.3
Lautamäki, R.4
Merrill, J.5
Nekolla, S.G.6
-
126
-
-
0032032521
-
Assessment of diagnostic performance of quantitative flow measurements in normal subjects and patients with angiographically documented coronary artery disease by means of nitrogen-13 ammonia and positron emission tomography
-
COI: 1:STN:280:DyaK1c7mtFOgug%3D%3D, PID: 9502631
-
Muzik O, Duvernoy C, Beanlands R, Sawada S, Dayanikli F, Wolfe E, et al. Assessment of diagnostic performance of quantitative flow measurements in normal subjects and patients with angiographically documented coronary artery disease by means of nitrogen-13 ammonia and positron emission tomography. J Am Coll Cardiol 1998;31:534-40.
-
(1998)
J Am Coll Cardiol
, vol.31
, pp. 534-540
-
-
Muzik, O.1
Duvernoy, C.2
Beanlands, R.3
Sawada, S.4
Dayanikli, F.5
Wolfe, E.6
-
127
-
-
84864767807
-
Diagnostic value of 13N-ammonia myocardial perfusion PET: Added value of myocardial flow reserve
-
COI: 1:CAS:528:DC%2BC38XhtlymtrzN, PID: 22776752
-
Fiechter M, Ghadri JR, Gebhard C, Fuchs TA, Pazhenkottil AP, Nkoulou RN, et al. Diagnostic value of 13N-ammonia myocardial perfusion PET: Added value of myocardial flow reserve. J Nucl Med 2012;53:1230-4. doi:10.2967/jnumed.111.101840.
-
(2012)
J Nucl Med
, vol.53
, pp. 1230-1234
-
-
Fiechter, M.1
Ghadri, J.R.2
Gebhard, C.3
Fuchs, T.A.4
Pazhenkottil, A.P.5
Nkoulou, R.N.6
-
128
-
-
84865094762
-
Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease?
-
PID: 22415819
-
Ziadi MC, deKemp RA, Williams K, Guo A, Renaud JM, Chow BJW, et al. Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J Nucl Cardiol 2012;19:670-80. doi:10.1007/s12350-011-9506-5.
-
(2012)
J Nucl Cardiol
, vol.19
, pp. 670-680
-
-
Ziadi, M.C.1
deKemp, R.A.2
Williams, K.3
Guo, A.4
Renaud, J.M.5
Chow, B.J.W.6
-
129
-
-
84897931387
-
Preserved coronary flow reserve effectively excludes high-risk coronary artery disease on angiography
-
PID: 24408896
-
Naya M, Murthy VL, Taqueti VR, Foster CR, Klein J, Garber M, et al. Preserved coronary flow reserve effectively excludes high-risk coronary artery disease on angiography. J Nucl Med 2014;55:248-55. doi:10.2967/jnumed.113.121442.
-
(2014)
J Nucl Med
, vol.55
, pp. 248-255
-
-
Naya, M.1
Murthy, V.L.2
Taqueti, V.R.3
Foster, C.R.4
Klein, J.5
Garber, M.6
-
130
-
-
66449098736
-
Comparison of positron emission tomography measurement of adenosine-stimulated absolute myocardial blood flow versus relative myocardial tracer content for physiological assessment of coronary artery stenosis severity and location
-
Hajjiri MM, Leavitt MB, Zheng H, Spooner AE, Fischman AJ, Gewirtz H. Comparison of positron emission tomography measurement of adenosine-stimulated absolute myocardial blood flow versus relative myocardial tracer content for physiological assessment of coronary artery stenosis severity and location. J Am Coll Cardiol Imaging 2009;2:751-8. doi:10.1016/j.jcmg.2009.04.004.
-
(2009)
J Am Coll Cardiol Imaging
, vol.2
, pp. 751-758
-
-
Hajjiri, M.M.1
Leavitt, M.B.2
Zheng, H.3
Spooner, A.E.4
Fischman, A.J.5
Gewirtz, H.6
-
131
-
-
77955466812
-
Cardiac positron emission tomography/computed tomography imaging accurately detects anatomically and functionally significant coronary artery disease
-
COI: 1:STN:280:DC%2BC3cjjsV2itg%3D%3D, PID: 20660808
-
Kajander S, Joutsiniemi E, Saraste M, Pietilä M, Ukkonen H, Saraste A, et al. Cardiac positron emission tomography/computed tomography imaging accurately detects anatomically and functionally significant coronary artery disease. Circulation 2010;122:603-13. doi:10.1161/CIRCULATIONAHA.109.915009.
-
(2010)
Circulation
, vol.122
, pp. 603-613
-
-
Kajander, S.1
Joutsiniemi, E.2
Saraste, M.3
Pietilä, M.4
Ukkonen, H.5
Saraste, A.6
-
132
-
-
0032716443
-
Assessment of the reproducibility of baseline and hyperemic myocardial blood flow measurements with 15O-labeled water and PET
-
COI: 1:STN:280:DC%2BD3c%2FivFGisg%3D%3D, PID: 10565780
-
Kaufmann PA, Gnecchi-Ruscone T, Yap JT, Rimoldi O, Camici PG. Assessment of the reproducibility of baseline and hyperemic myocardial blood flow measurements with 15O-labeled water and PET. J Nucl Med 1999;40:1848-56.
-
(1999)
J Nucl Med
, vol.40
, pp. 1848-1856
-
-
Kaufmann, P.A.1
Gnecchi-Ruscone, T.2
Yap, J.T.3
Rimoldi, O.4
Camici, P.G.5
-
133
-
-
0037318135
-
Bicycle exercise stress in PET for assessment of coronary flow reserve: Repeatability and comparison with adenosine stress
-
PID: 12571202
-
Wyss CA, Koepfli P, Mikolajczyk K, Burger C, von Schulthess GK, Kaufmann PA. Bicycle exercise stress in PET for assessment of coronary flow reserve: Repeatability and comparison with adenosine stress. J Nucl Med 2003;44:146-54.
-
(2003)
J Nucl Med
, vol.44
, pp. 146-154
-
-
Wyss, C.A.1
Koepfli, P.2
Mikolajczyk, K.3
Burger, C.4
von Schulthess, G.K.5
Kaufmann, P.A.6
-
134
-
-
33750595395
-
Repeatability of cold pressor test-induced flow increase assessed with H2 15O and PET
-
PID: 16954548
-
Siegrist PT, Gaemperli O, Koepfli P, Schepis T, Namdar M, Valenta I, et al. Repeatability of cold pressor test-induced flow increase assessed with H2 15O and PET. J Nucl Med 2006;47:1420-6.
-
(2006)
J Nucl Med
, vol.47
, pp. 1420-1426
-
-
Siegrist, P.T.1
Gaemperli, O.2
Koepfli, P.3
Schepis, T.4
Namdar, M.5
Valenta, I.6
-
135
-
-
34547414555
-
Assessment of intra- and interobserver reproducibility of rest and cold pressor test-stimulated myocardial blood flow with 13N-ammonia and PET
-
PID: 17334762
-
Schindler TH, Zhang X-L, Prior JO, Cadenas J, Dahlbom M, Sayre J, et al. Assessment of intra- and interobserver reproducibility of rest and cold pressor test-stimulated myocardial blood flow with 13N-ammonia and PET. Eur J Nucl Med Mol Imaging 2007;34:1178-88.
-
(2007)
Eur J Nucl Med Mol Imaging
, vol.34
, pp. 1178-1188
-
-
Schindler, T.H.1
Zhang, X.-L.2
Prior, J.O.3
Cadenas, J.4
Dahlbom, M.5
Sayre, J.6
-
136
-
-
0035554648
-
NEMA evaluation of the first and second generation of the Ecat Exact and Ecat Exact HR family of scanners
-
vol 3, 2001:1223-26
-
Eriksson L, Wienhard K, Eriksson M, Casey ME, Knoess C, Bruckbauer T, et al. NEMA evaluation of the first and second generation of the Ecat Exact and Ecat Exact HR family of scanners. In: 2001 IEEE Nuclear Science Symposium Conference Record. vol 3, 2001:1223-26. doi:10.1109/NSSMIC.2001.1008556.
-
2001 IEEE Nuclear Science Symposium Conference Record
-
-
Eriksson, L.1
Wienhard, K.2
Eriksson, M.3
Casey, M.E.4
Knoess, C.5
Bruckbauer, T.6
-
137
-
-
8344280944
-
NEMA NU2-2001 guided performance evaluation of four Siemens ECAT PET scanners
-
Herzog H, Tellmann L, Hocke C, Pietrzyk U, Casey ME, Kuwert T. NEMA NU2-2001 guided performance evaluation of four Siemens ECAT PET scanners. IEEE Trans Nucl Sci. 2004;51:2662-9. doi:10.1109/TNS.2004.835778.
-
(2004)
IEEE Trans Nucl Sci
, vol.51
, pp. 2662-2669
-
-
Herzog, H.1
Tellmann, L.2
Hocke, C.3
Pietrzyk, U.4
Casey, M.E.5
Kuwert, T.6
-
138
-
-
3242717954
-
Imaging characteristics of a 3-dimensional GSO whole-body PET camera
-
COI: 1:CAS:528:DC%2BD2cXnsFygtro%3D, PID: 15181139
-
Surti S, Karp JS. Imaging characteristics of a 3-dimensional GSO whole-body PET camera. J Nucl Med 2004;45:1040-9.
-
(2004)
J Nucl Med
, vol.45
, pp. 1040-1049
-
-
Surti, S.1
Karp, J.S.2
-
139
-
-
2942584985
-
Performance evaluation of the new whole-body PET/CT scanner: Discovery ST
-
PID: 14770270
-
Bettinardi V, Danna M, Savi A, Lecchi M, Castiglioni I, Gilardi M, et al. Performance evaluation of the new whole-body PET/CT scanner: Discovery ST. Eur J Nucl Med Mol Imaging 2004;31:867-81. doi:10.1007/s00259-003-1444-2.
-
(2004)
Eur J Nucl Med Mol Imaging
, vol.31
, pp. 867-881
-
-
Bettinardi, V.1
Danna, M.2
Savi, A.3
Lecchi, M.4
Castiglioni, I.5
Gilardi, M.6
-
140
-
-
34247204476
-
NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes
-
PID: 17138738
-
Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med 2006;47:1960-7.
-
(2006)
J Nucl Med
, vol.47
, pp. 1960-1967
-
-
Kemp, B.J.1
Kim, C.2
Williams, J.J.3
Ganin, A.4
Lowe, V.J.5
-
141
-
-
34748880661
-
Performance of the new generation of whole-body PET/CT scanners: Discovery STE and discovery VCT
-
PID: 17661031
-
Teräs M, Tolvanen T, Johansson J, Williams J, Knuuti J. Performance of the new generation of whole-body PET/CT scanners: Discovery STE and discovery VCT. Eur J Nucl Med Mol Imaging 2007;34:1683-92. doi:10.1007/s00259-007-0493-3.
-
(2007)
Eur J Nucl Med Mol Imaging
, vol.34
, pp. 1683-1692
-
-
Teräs, M.1
Tolvanen, T.2
Johansson, J.3
Williams, J.4
Knuuti, J.5
-
142
-
-
0019450543
-
N-13 ammonia as an indicator of myocardial blood flow
-
COI: 1:CAS:528:DyaL3MXkt1SmsLY%3D, PID: 7226473
-
Schelbert HR, Phelps ME, Huang SC, MacDonald NS, Hansen H, Selin C, et al. N-13 ammonia as an indicator of myocardial blood flow. Circulation 1981;63:1259-72.
-
(1981)
Circulation
, vol.63
, pp. 1259-1272
-
-
Schelbert, H.R.1
Phelps, M.E.2
Huang, S.C.3
MacDonald, N.S.4
Hansen, H.5
Selin, C.6
|