메뉴 건너뛰기




Volumn 25, Issue 5, 2006, Pages 529-538

Investigation of time-of-flight benefit for fully 3-D PET

Author keywords

Contrast; Image quality; Lesion detectability; LSO; Noise; NPW; Time of flight PET; TOF

Indexed keywords

DATA REDUCTION; IMAGE QUALITY; IMAGE RECONSTRUCTION; LANTHANUM COMPOUNDS; MATHEMATICAL MODELS; OPTICAL RESOLVING POWER;

EID: 33646388372     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2006.871419     Document Type: Article
Times cited : (154)

References (32)
  • 1
    • 0001269233 scopus 로고
    • A promising new scintillator - Cerium-doped lutetium oxyorthosilicate
    • C. L. Melcher and J. S. Schweitzer, "A promising new scintillator - cerium-doped lutetium oxyorthosilicate," Nucl. Instrum. Meth. Phys. Res. A. vol. 314, pp. 212-214, 1992.
    • (1992) Nucl. Instrum. Meth. Phys. Res. A , vol.314 , pp. 212-214
    • Melcher, C.L.1    Schweitzer, J.S.2
  • 2
    • 0026902676 scopus 로고
    • Cerium-doped lutetium oxyorthosilicate: A fast, efficient new scintillator
    • Aug.
    • _, "Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator," IEEE Trans. Nucl. Sci., vol. 39, no. 4, pp. 502-505, Aug. 1992.
    • (1992) IEEE Trans. Nucl. Sci. , vol.39 , Issue.4 , pp. 502-505
  • 3
    • 0348076064 scopus 로고    scopus 로고
    • Is LSO the future of PET? for
    • R. Nutt, "Is LSO the future of PET? for," Eur. J. Nucl. Med., vol. 29, pp. 1523-1525, 2002.
    • (2002) Eur. J. Nucl. Med. , vol.29 , pp. 1523-1525
    • Nutt, R.1
  • 6
    • 0038043944 scopus 로고    scopus 로고
    • Investigation of lanthanum scintillators for 3-D PET
    • Jun.
    • S. Surti, J. S. Karp, G. Muehllehner, and P. S. Raby, "Investigation of lanthanum scintillators for 3-D PET," IEEE Trans. Nucl. Sci., vol. 50, no. 3, pp. 348-354, Jun. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.3 , pp. 348-354
    • Surti, S.1    Karp, J.S.2    Muehllehner, G.3    Raby, P.S.4
  • 8
    • 5744224129 scopus 로고    scopus 로고
    • Image quality assessment of LaBr3-based whole-body 3D PET scanners: A Monte Carlo evaluation
    • S. Surti, J. S. Karp, and G. Muehllehner, "Image quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation," Phys. Med. Biol., vol. 49, pp. 4593-4610, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4593-4610
    • Surti, S.1    Karp, J.S.2    Muehllehner, G.3
  • 9
    • 0018842047 scopus 로고
    • Potential advantages of a cesium fluoride scintillator for a time-of-flight positron camera
    • R. Allemand, C. Gresset, and J. Vacher, "Potential advantages of a cesium fluoride scintillator for a time-of-flight positron camera," J. Nucl. Med., vol. 21, pp. 153-155, 1980.
    • (1980) J. Nucl. Med. , vol.21 , pp. 153-155
    • Allemand, R.1    Gresset, C.2    Vacher, J.3
  • 10
    • 0020206557 scopus 로고
    • Super PETT I: A positron emission tomograph utilizing photon time-of-flight information
    • M. Ter-Pogossian, D. Ficke, M. Yamamoto, and J. T. Hood, "Super PETT I: a positron emission tomograph utilizing photon time-of-flight information," IEEE Trans. Nucl. Sci., vol. NS-1, pp. 179-187, 1982.
    • (1982) IEEE Trans. Nucl. Sci. , vol.NS-1 , pp. 179-187
    • Ter-Pogossian, M.1    Ficke, D.2    Yamamoto, M.3    Hood, J.T.4
  • 12
    • 0033337104 scopus 로고    scopus 로고
    • Prospects for time-of-flight PET using LSO scintillator
    • Jun.
    • W. W. Moses and S. E. Derenzo, "Prospects for time-of-flight PET using LSO scintillator," IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 474-478, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 474-478
    • Moses, W.W.1    Derenzo, S.E.2
  • 13
    • 0142126690 scopus 로고    scopus 로고
    • Time of flight in PET revisited
    • Oct.
    • W. W. Moses, "Time of flight in PET revisited," IEEE Trans. Nucl. Sci., vol. 50, no. 5, pp. 1325-1330, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1325-1330
    • Moses, W.W.1
  • 14
    • 0031854801 scopus 로고    scopus 로고
    • Time-of-flight PET
    • T. K. Lewellen, "Time-of-flight PET," Sem. Nucl. Med., vol. 28, pp. 268-275, 1998.
    • (1998) Sem. Nucl. Med. , vol.28 , pp. 268-275
    • Lewellen, T.K.1
  • 15
    • 0003710941 scopus 로고    scopus 로고
    • NEMA Standards Publication NU 2-2001, National Electrical Manufacturers Association. Rosslyn, VA
    • NEMA Standards Publication NU 2-2001, "Performance Measurements of Positron Emission Tomographs," National Electrical Manufacturers Association. Rosslyn, VA, 2001.
    • (2001) Performance Measurements of Positron Emission Tomographs
  • 17
    • 0020701632 scopus 로고
    • Time-of-flight positron emission tomography - Status relative to conventional PET
    • T. F. Budinger, "Time-of-flight positron emission tomography - status relative to conventional PET," J. Nucl. Med., vol. 24, pp. 73-76, 1983.
    • (1983) J. Nucl. Med. , vol.24 , pp. 73-76
    • Budinger, T.F.1
  • 18
    • 0019656680 scopus 로고
    • Image-reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography
    • T. Tomitani, "Image-reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography," IEEE Trans. Nucl. Sci., vol. NS-28, pp. 4582-4589, 1981.
    • (1981) IEEE Trans. Nucl. Sci. , vol.NS-28 , pp. 4582-4589
    • Tomitani, T.1
  • 19
    • 0032761238 scopus 로고    scopus 로고
    • Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations
    • L. E. Adam, J. S. Karp, and G. Brix, "Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations," Phys. Med. Biol., vol. 44, pp. 2879-2895, 1999.
    • (1999) Phys. Med. Biol. , vol.44 , pp. 2879-2895
    • Adam, L.E.1    Karp, J.S.2    Brix, G.3
  • 20
    • 0021830446 scopus 로고
    • Performance of a position-sensitive scintillation detector
    • J. S. Karp and G. Muehllehner, "Performance of a position-sensitive scintillation detector," Phys. Med. Biol., vol. 30, pp. 643-655, 1985.
    • (1985) Phys. Med. Biol. , vol.30 , pp. 643-655
    • Karp, J.S.1    Muehllehner, G.2
  • 21
    • 0024513497 scopus 로고
    • The high count rate performance of a two-dimensionally position-sensitive detector for positron emission tomography
    • D. A. Mankoff, G. Muehllehner, and J. S. Karp, "The high count rate performance of a two-dimensionally position-sensitive detector for positron emission tomography," Phys. Med. Biol., vol. 34, pp. 437-456, 1989.
    • (1989) Phys. Med. Biol. , vol.34 , pp. 437-456
    • Mankoff, D.A.1    Muehllehner, G.2    Karp, J.S.3
  • 24
    • 5744254159 scopus 로고    scopus 로고
    • Effect of patient thickness on noise equivalent count rates for 2D and fully-3D whole-body PET imaging
    • P. E. Kinahan, S. Surti, R. D. Badawi, G. El Fakhri, J. S. Karp, and T. K. Lewellen, "Effect of patient thickness on noise equivalent count rates for 2D and fully-3D whole-body PET imaging," J. Nucl. Med., vol. 45, pp. 102P-103P, 2004.
    • (2004) J. Nucl. Med. , vol.45
    • Kinahan, P.E.1    Surti, S.2    Badawi, R.D.3    El Fakhri, G.4    Karp, J.S.5    Lewellen, T.K.6
  • 25
    • 23844519353 scopus 로고    scopus 로고
    • Iterative image reconstruction using geometrically ordered subsets with list-mode data
    • Rome, Italy
    • L. M. Popescu, "Iterative image reconstruction using geometrically ordered subsets with list-mode data," presented at the 2004 IEEE Nuclear Science Symp. Medical Imaging Conf., Rome, Italy, 2004.
    • (2004) 2004 IEEE Nuclear Science Symp. Medical Imaging Conf.
    • Popescu, L.M.1
  • 27
    • 3242772275 scopus 로고    scopus 로고
    • Optimization of a fully 3D single scatter simulation algortihm for 3D PET
    • R. Accorsi, L.-E. Adam, M. E. Werner, and J. S. Karp, "Optimization of a fully 3D single scatter simulation algortihm for 3D PET," Phys. Med. Biol., vol. 49, pp. 2577-2598, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2577-2598
    • Accorsi, R.1    Adam, L.-E.2    Werner, M.E.3    Karp, J.S.4
  • 28
    • 0027425561 scopus 로고
    • Model observers for assessment of image quality
    • H. H. Barrett, J. Yao, J. P. Rolland, and K. J. Myers, "Model observers for assessment of image quality," PNAS, vol. 90, pp. 9758-9765, 1993.
    • (1993) PNAS , vol.90 , pp. 9758-9765
    • Barrett, H.H.1    Yao, J.2    Rolland, J.P.3    Myers, K.J.4
  • 29
    • 0019405245 scopus 로고
    • Lesion detection and signal-to-noise ratio in CT images
    • P. F. Judy, R. G. Swensson, and M. Szulc, "Lesion detection and signal-to-noise ratio in CT images," Med. Phys., vol. 8, pp. 13-23, 1981.
    • (1981) Med. Phys. , vol.8 , pp. 13-23
    • Judy, P.F.1    Swensson, R.G.2    Szulc, M.3
  • 32
    • 12144266827 scopus 로고    scopus 로고
    • Practical issues and methodology in assessment of image quality using model observers
    • Medical Imaging 1997: Physics of Medical Imaging, May
    • C. K. Abbey, H. H. Barrett, and M. P. Eckstein, "Practical issues and methodology in assessment of image quality using model observers," Proc. SPIE, vol. 3032, Medical Imaging 1997: Physics of Medical Imaging, pp. 182-194, May 1997.
    • (1997) Proc. SPIE , vol.3032 , pp. 182-194
    • Abbey, C.K.1    Barrett, H.H.2    Eckstein, M.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.