Volumn 34, Issue 11, 2007, Pages 1765-1774

Quantification of myocardial blood flow with 82Rb dynamic PET imaging

Author keywords

Myocardial blood flow; Perfusion; PET; Rubidium 82; Tracer kinetic modeling

Indexed keywords

AMINOPHYLLINE; AMMONIA N 13; DIPYRIDAMOLE; RUBIDIUM 82;

EID: 34249701087     PISSN: 16197070     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00259-007-0478-2     Document Type: Article
Times cited : (340)

References (57)
  • 2
    • 0025542036 scopus 로고
    • Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography: Exploration of a mathematical model
    • Herrero P, Markham J, Shelton ME, Weinheimer CJ, Bergmann SR. Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography: exploration of a mathematical model. Circulation 1990;82:1377-86.
    • (1990) Circulation , vol.82 , pp. 1377-1386
    • Herrero, P.1    Markham, J.2    Shelton, M.E.3    Weinheimer, C.J.4    Bergmann, S.R.5
  • 3
    • 0029815801 scopus 로고    scopus 로고
    • Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia
    • Yoshida K, Mullani N, Gould KL. Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia. J Nucl Med 1996;37:1701-12.
    • (1996) J Nucl Med , vol.37 , pp. 1701-1712
    • Yoshida, K.1    Mullani, N.2    Gould, K.L.3
  • 5
    • 0026536640 scopus 로고
    • Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography
    • Herrero P, Markham J, Shelton ME, Bergmann SR. Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography. Circ Res 1992;70:496-507.
    • (1992) Circ Res , vol.70 , pp. 496-507
    • Herrero, P.1    Markham, J.2    Shelton, M.E.3    Bergmann, S.R.4
  • 6
    • 0030941496 scopus 로고    scopus 로고
    • Consequences of using a simplified kinetic model for dynamic PET data
    • Coxson PG, Huesman RH, Borland L. Consequences of using a simplified kinetic model for dynamic PET data. J Nucl Med 1997;38:660-7.
    • (1997) J Nucl Med , vol.38 , pp. 660-667
    • Coxson, P.G.1    Huesman, R.H.2    Borland, L.3
  • 7
    • 0018750969 scopus 로고
    • Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease
    • Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. N Engl J Med 1979;300:1350-8.
    • (1979) N Engl J Med , vol.300 , pp. 1350-1358
    • Diamond, G.A.1    Forrester, J.S.2
  • 9
    • 0032946357 scopus 로고    scopus 로고
    • Manufacture of strontium-82/rubidium-82 generators and quality control of rubidium-82 chloride for myocardial perfusion imaging in patients using positron emission tomography
    • Alvarez-Diez TM, deKemp R, Beanlands R, Vincent J. Manufacture of strontium-82/rubidium-82 generators and quality control of rubidium-82 chloride for myocardial perfusion imaging in patients using positron emission tomography. Appl Radiat Isot 1999;50:1015-23.
    • (1999) Appl Radiat Isot , vol.50 , pp. 1015-1023
    • Alvarez-Diez, T.M.1    Dekemp, R.2    Beanlands, R.3    Vincent, J.4
  • 10
    • 0002751685 scopus 로고    scopus 로고
    • The ECAT ART scanner for positron emission tomography. 1. Improvements in performance characteristics
    • Townsend DW, Beyer T, Jerin J, Watson CC, Young J, Nutt R. The ECAT ART scanner for positron emission tomography. 1. Improvements in performance characteristics. Clin Positron Imaging 1999;2:5-15.
    • (1999) Clin Positron Imaging , vol.2 , pp. 5-15
    • Townsend, D.W.1    Beyer, T.2    Jerin, J.3    Watson, C.C.4    Young, J.5    Nutt, R.6
  • 12
    • 34047252834 scopus 로고    scopus 로고
    • 82Rb generator for cardiac perfusion imaging with positron emission tomography
    • 82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol 2007;52:659-73.
    • (2007) Phys Med Biol , vol.52 , pp. 659-673
    • Klein, R.1    Adler, A.2    Beanlands, R.S.3    Dekemp, R.A.4
  • 14
    • 0031076959 scopus 로고    scopus 로고
    • Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging
    • Watson CC, Newport D, Casey ME, deKemp RA, Beanlands RSSM. Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging. IEEE Trans Nucl Sci 1997;44:90-7.
    • (1997) IEEE Trans Nucl Sci , vol.44 , pp. 90-97
    • Watson, C.C.1    Newport, D.2    Casey, M.E.3    Dekemp, R.A.4    Rssm, B.5
  • 15
    • 0034244929 scopus 로고    scopus 로고
    • New, faster, image-based scatter correction of 3D PET
    • Watson CC. New, faster, image-based scatter correction of 3D PET. IEEE Trans Nucl Sci 2000;47:1587-94.
    • (2000) IEEE Trans Nucl Sci , vol.47 , pp. 1587-1594
    • Watson, C.C.1
  • 17
    • 0029903123 scopus 로고    scopus 로고
    • Automated determination of the left ventricular long axis in cardiac positron tomography
    • deKemp RA, Nahmias C. Automated determination of the left ventricular long axis in cardiac positron tomography. Physiol Meas 1996;17:95-108.
    • (1996) Physiol Meas , vol.17 , pp. 95-108
    • Dekemp, R.A.1    Nahmias, C.2
  • 18
    • 0027211982 scopus 로고
    • An automated analysis program for the evaluation of cardiac PET studies: Initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia
    • Laubenbacher C, Rothley J, Sitomer J, Beanlands R, Sawada S, Sutor R, et al. An automated analysis program for the evaluation of cardiac PET studies: initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia. J Nucl Med 1993;34:968-78.
    • (1993) J Nucl Med , vol.34 , pp. 968-978
    • Laubenbacher, C.1    Rothley, J.2    Sitomer, J.3    Beanlands, R.4    Sawada, S.5    Sutor, R.6
  • 20
    • 0025255149 scopus 로고
    • Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging
    • Hutchins GD, Schwaiger M, Rosenspire KC, Krivokapich J, Schelbert H, Kuhl DE. Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging. J Am Coll Cardiol 1990;15:1032-42.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 1032-1042
    • Hutchins, G.D.1    Schwaiger, M.2    Rosenspire, K.C.3    Krivokapich, J.4    Schelbert, H.5    Kuhl, D.E.6
  • 22
    • 0028896734 scopus 로고
    • Variability and reproducibility of rubidium-82 kinetic parameters in the myocardium of the anesthetized canine
    • Coxson PG, Brennan KM, Huesman RH, Lim S, Budinger TF. Variability and reproducibility of rubidium-82 kinetic parameters in the myocardium of the anesthetized canine. J Nucl Med 1995;36:287-96.
    • (1995) J Nucl Med , vol.36 , pp. 287-296
    • Coxson, P.G.1    Brennan, K.M.2    Huesman, R.H.3    Lim, S.4    Budinger, T.F.5
  • 24
    • 0026710876 scopus 로고
    • A region of interest strategy for minimizing resolution distortions in quantitative myocardial PET studies
    • Hutchins GD, Caraher JM, Raylman RR. A region of interest strategy for minimizing resolution distortions in quantitative myocardial PET studies. J Nucl Med 1992;33:1243-50.
    • (1992) J Nucl Med , vol.33 , pp. 1243-1250
    • Hutchins, G.D.1    Caraher, J.M.2    Raylman, R.R.3
  • 25
    • 0027391244 scopus 로고
    • Validation of nitrogen-13-ammonia tracer kinetic model for quantification of myocardial blood flow using PET
    • Muzik O, Beanlands RSB, Hutchins GD, Mangner TJ, Nguyen N, Schwaiger M. Validation of nitrogen-13-ammonia tracer kinetic model for quantification of myocardial blood flow using PET. J Nucl Med 1993;34:83-91.
    • (1993) J Nucl Med , vol.34 , pp. 83-91
    • Muzik, O.1    Beanlands, R.S.B.2    Hutchins, G.D.3    Mangner, T.J.4    Nguyen, N.5    Schwaiger, M.6
  • 27
    • 0021431509 scopus 로고
    • Multiexponential, multicompartmental, and noncompartmental modeling. II. Data analysis and statistical considerations
    • Landaw EM, DiStefano JJ. Multiexponential, multicompartmental, and noncompartmental modeling. II. Data analysis and statistical considerations. Am J Physiol 1984;246:R665-77.
    • (1984) Am J Physiol , vol.246
    • Landaw, E.M.1    Distefano, J.J.2
  • 28
    • 13344292421 scopus 로고
    • Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles
    • Renkin EM. Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles. Am J Physiol 1959;197:1205-10.
    • (1959) Am J Physiol , vol.197 , pp. 1205-1210
    • Renkin, E.M.1
  • 29
    • 78651133453 scopus 로고
    • Permeability of capillaries in various organs as determined by use of the indicator diffusion method
    • Crone C. Permeability of capillaries in various organs as determined by use of the indicator diffusion method. Acta Physiol Scand 1963;58:292-305.
    • (1963) Acta Physiol Scand , vol.58 , pp. 292-305
    • Crone, C.1
  • 32
    • 0027530709 scopus 로고
    • Automated region definition for cardiac nitrogen-13-ammonia PET imaging
    • Muzik O, Beanlands R, Wolfe E, Hutchins GD, Schwaiger M. Automated region definition for cardiac nitrogen-13-ammonia PET imaging. J Nucl Med 1993;34:336-44.
    • (1993) J Nucl Med , vol.34 , pp. 336-344
    • Muzik, O.1    Beanlands, R.2    Wolfe, E.3    Hutchins, G.D.4    Schwaiger, M.5
  • 33
    • 0028800163 scopus 로고
    • Noninvasive quantification of regional myocardial flow reserve in patients with coronary atherosclerosis using nitrogen-13 ammonia positron emission tomography. Determination of extent of altered vascular reactivity
    • Beanlands RS, Muzik O, Melon P, Sutor R, Sawada S, Muller D, et al. Noninvasive quantification of regional myocardial flow reserve in patients with coronary atherosclerosis using nitrogen-13 ammonia positron emission tomography. Determination of extent of altered vascular reactivity. J Am Coll Cardiol 1995;26:1465-75.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 1465-1675
    • Beanlands, R.S.1    Muzik, O.2    Melon, P.3    Sutor, R.4    Sawada, S.5    Muller, D.6
  • 34
    • 0025829868 scopus 로고
    • Coronary vasodilation is impaired in both hypertrophied and nonhypertrophied myocardium of patients with hypertrophic cardiomyopathy: A study with nitrogen-13 ammonia and positron emission tomography
    • Camici P, Chiriatti G, Lorenzoni R, Bellina RC, Gistri R, Italiani G, et al. Coronary vasodilation is impaired in both hypertrophied and nonhypertrophied myocardium of patients with hypertrophic cardiomyopathy: a study with nitrogen-13 ammonia and positron emission tomography. J Am Coll Cardiol 1991;17:879-86.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 879-886
    • Camici, P.1    Chiriatti, G.2    Lorenzoni, R.3    Bellina, R.C.4    Gistri, R.5    Italiani, G.6
  • 36
    • 0026446396 scopus 로고
    • Comparison of maximal myocardial blood flow during adenosine infusion with that of intravenous dipyridamole in normal men
    • Chan SY, Brunken RC, Czernin J, Porenta G, Kuhle W, Krivokapich J, et al. Comparison of maximal myocardial blood flow during adenosine infusion with that of intravenous dipyridamole in normal men. J Am Coll Cardiol 1992;20:979-85.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 979-985
    • Chan, S.Y.1    Brunken, R.C.2    Czernin, J.3    Porenta, G.4    Kuhle, W.5    Krivokapich, J.6
  • 37
    • 0031060467 scopus 로고    scopus 로고
    • Quantitative PET measurements of regional myocardial blood flow: Observations in humans with ischemic heart disease
    • Gewirtz H, Skopicki HA, Abraham SA, Castano H, Dinsmore RE, Alpert NM, et al. Quantitative PET measurements of regional myocardial blood flow: observations in humans with ischemic heart disease. Cardiology 1997;88:62-70.
    • (1997) Cardiology , vol.88 , pp. 62-70
    • Gewirtz, H.1    Skopicki, H.A.2    Abraham, S.A.3    Castano, H.4    Dinsmore, R.E.5    Alpert, N.M.6
  • 38
    • 14744291508 scopus 로고    scopus 로고
    • Application of cardiac molecular imaging using positron emission tomography in evaluation of drug and therapeutics for cardiovascular disorders
    • Yoshinaga K, Chow BJW, deKemp RA, Thorn S, Ruddy TD, Davies RA, et al. Application of cardiac molecular imaging using positron emission tomography in evaluation of drug and therapeutics for cardiovascular disorders. Curr Pharm Des 2005;11:903-32.
    • (2005) Curr Pharm des , vol.11 , pp. 903-932
    • Yoshinaga, K.1    Chow, B.J.W.2    Dekemp, R.A.3    Thorn, S.4    Ruddy, T.D.5    Davies, R.A.6
  • 40
    • 0029815952 scopus 로고    scopus 로고
    • Reproducibility of measurements of regional resting and hyperemic myocardial blood flow assessed with PET
    • Nagamachi S, Czernin J, Kim AS, Sun KT, Böttcher M, Phelps ME, et al. Reproducibility of measurements of regional resting and hyperemic myocardial blood flow assessed with PET. J Nucl Med 1996;37:1626-30.
    • (1996) J Nucl Med , vol.37 , pp. 1626-1630
    • Nagamachi, S.1    Czernin, J.2    Kim, A.S.3    Sun, K.T.4    Böttcher, M.5    Phelps, M.E.6
  • 41
    • 0034077110 scopus 로고    scopus 로고
    • Positron emission tomography and myocardial imaging
    • Camici PG. Positron emission tomography and myocardial imaging. Heart 2000;83:475-80.
    • (2000) Heart , vol.83 , pp. 475-480
    • Camici, P.G.1
  • 44
    • 0028281838 scopus 로고
    • Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography
    • De Bruyne B, Baudhuin T, Melin JA, Pijls NH, Sys SU, Bol A, et al. Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography. Circulation 1994;89:1013-22.
    • (1994) Circulation , vol.89 , pp. 1013-1022
    • De Bruyne, B.1    Baudhuin, T.2    Melin, J.A.3    Pijls, N.H.4    Sys, S.U.5    Bol, A.6
  • 45
    • 0021912085 scopus 로고
    • Kinetics of rubidium-82 after coronary occlusion and reperfusion. Assessment of patency and viability in open-chested dogs
    • Goldstein RA. Kinetics of rubidium-82 after coronary occlusion and reperfusion. Assessment of patency and viability in open-chested dogs. J Clin Invest 1985;75:1131-7.
    • (1985) J Clin Invest , vol.75 , pp. 1131-1137
    • Goldstein, R.A.1
  • 46
    • 0022870910 scopus 로고
    • Rubidium-82 kinetics after coronary occlusion: Temporal relation of net myocardial accumulation and viability in open-chested dogs
    • Goldstein RA. Rubidium-82 kinetics after coronary occlusion: Temporal relation of net myocardial accumulation and viability in open-chested dogs. J Nucl Med 1986;1456-61.
    • (1986) J Nucl Med , pp. 1456-1461
    • Goldstein, R.A.1
  • 47
    • 0026033052 scopus 로고
    • Myocardial metabolism of fluorodeoxyglucose compared to cell membrane integrity for the potassium analogue rubidium-82 for assessing infarct size in man by PET
    • Gould KL, Yoshida K, Hess MJ, Haynie M, Mullani N, Smalling RW. Myocardial metabolism of fluorodeoxyglucose compared to cell membrane integrity for the potassium analogue rubidium-82 for assessing infarct size in man by PET. J Nucl Med 1991;32:1-9.
    • (1991) J Nucl Med , vol.32 , pp. 1-9
    • Gould, K.L.1    Yoshida, K.2    Hess, M.J.3    Haynie, M.4    Mullani, N.5    Smalling, R.W.6
  • 48
    • 0030053328 scopus 로고    scopus 로고
    • Myocardial rubidium-82 tissue kinetics assessed by dynamic positron emission tomography as a marker of myocardial cell membrane integrity and viability
    • vom Dahl J, Muzik O, Wolfe ERJ, Allman C, Hutchins G, Schwaiger M. Myocardial rubidium-82 tissue kinetics assessed by dynamic positron emission tomography as a marker of myocardial cell membrane integrity and viability. Circulation 1996;93:238-45.
    • (1996) Circulation , vol.93 , pp. 238-245
    • Vom Dahl, J.1    Muzik, O.2    Wolfe, E.R.J.3    Allman, C.4    Hutchins, G.5    Schwaiger, M.6
  • 49
    • 18344383977 scopus 로고    scopus 로고
    • Positron emission tomography of the heart: Methodology, findings in the normal and the diseased heart, and clinical applications
    • Springer Berlin Heidelberg New York
    • Schelbert H. Positron emission tomography of the heart: methodology, findings in the normal and the diseased heart, and clinical applications. In: Phelps ME, editor. PET molecular imaging and its biological applications. Berlin Heidelberg New York: Springer; 2004; p. 389-508.
    • (2004) PET Molecular Imaging and Its Biological Applications , pp. 389-508
    • Schelbert, H.1    Phelps, M.E.2
  • 54
    • 0021084091 scopus 로고
    • Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors
    • Mullani NA, Goldstein RA, Gould KL, Marani SK, Fisher DJ, O'Brien HA, et al. Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors. J Nucl Med 1983;24:898-906.
    • (1983) J Nucl Med , vol.24 , pp. 898-906
    • Mullani, N.A.1    Goldstein, R.A.2    Gould, K.L.3    Marani, S.K.4    Fisher, D.J.5    O'Brien, H.A.6
  • 55
    • 0026591689 scopus 로고
    • ST-segment depression during dipyridamole infusion, and its clinical, scintigraphic and hemodynamic correlates
    • Villanueva FS, Smith WH, Watson DD, Beller GA. ST-segment depression during dipyridamole infusion, and its clinical, scintigraphic and hemodynamic correlates. Am J Cardiol 1992;69:445-8.
    • (1992) Am J Cardiol , vol.69 , pp. 445-448
    • Villanueva, F.S.1    Smith, W.H.2    Watson, D.D.3    Beller, G.A.4
  • 56
    • 0142213162 scopus 로고    scopus 로고
    • PET myocardial glucose metabolism and perfusion imaging: Guidelines for patient preparation and data acquisition
    • Bacharach SL, Bax JJ, Case J, Delbeke D, Kurdziel KA, Martin WH, et al. PET myocardial glucose metabolism and perfusion imaging: guidelines for patient preparation and data acquisition. J Nucl Cardiol 2003;10:543-54.
    • (2003) J Nucl Cardiol , vol.10 , pp. 543-554
    • Bacharach, S.L.1    Bax, J.J.2    Case, J.3    Delbeke, D.4    Kurdziel, K.A.5    Martin, W.H.6
  • 57
    • 0142198899 scopus 로고    scopus 로고
    • PET myocardial glucose metabolism and perfusion imaging: Guidelines for interpretation and reporting
    • Schelbert HR, Beanlands R, Bengel F, Knuuti J, DiCarli M, Machac J, et al. PET myocardial glucose metabolism and perfusion imaging: guidelines for interpretation and reporting. J Nucl Cardiol 2003;10:557-71.
    • (2003) J Nucl Cardiol , vol.10 , pp. 557-571
    • Schelbert, H.R.1    Beanlands, R.2    Bengel, F.3    Knuuti, J.4    Dicarli, M.5    MacHac, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.