메뉴 건너뛰기




Volumn 43, Issue 1, 2015, Pages 177-185

Cardiac output monitoring: A contemporary assessment and review

Author keywords

Cardiac output; Echocardiography; Goal directed therapy; Hemodynamic monitoring; Minimally invasive monitoring; Pulmonary artery catheter

Indexed keywords

CARBON DIOXIDE;

EID: 84925602605     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0000000000000608     Document Type: Article
Times cited : (119)

References (101)
  • 1
    • 0000003630 scopus 로고
    • Measurement of cardiac output in anaesthetized animals by a thermodilution method
    • Fegler G: Measurement of cardiac output in anaesthetized animals by a thermodilution method. Q J Exp Physiol Cogn Med Sci 1954; 39:153-164
    • (1954) Q J Exp Physiol Cogn Med Sci , vol.39 , pp. 153-164
    • Fegler, G.1
  • 2
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan HJ, Ganz W, Forrester J, et al: Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970; 283:447-451
    • (1970) N Engl J Med , vol.283 , pp. 447-451
    • Swan, H.J.1    Ganz, W.2    Forrester, J.3
  • 3
    • 0015041424 scopus 로고
    • A new technique for measurement of cardiac output by thermodilution in man
    • Ganz W, Donoso R, Marcus HS, et al: A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 1971; 27:392-396
    • (1971) Am J Cardiol , vol.27 , pp. 392-396
    • Ganz, W.1    Donoso, R.2    Marcus, H.S.3
  • 4
    • 0037413466 scopus 로고    scopus 로고
    • Canadian Critical Care Clinical Trials Group: A randomized, controlled trial of the use of pulmonaryartery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant RF, et al; Canadian Critical Care Clinical Trials Group: A randomized, controlled trial of the use of pulmonaryartery catheters in high-risk surgical patients. N Engl J Med 2003; 348:5-14
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 5
    • 0345374592 scopus 로고    scopus 로고
    • French Pulmonary Artery Catheter Study Group: Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial
    • Richard C, Warszawski J, Anguel N, et al; French Pulmonary Artery Catheter Study Group: Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial. JAMA 2003; 290:2713-2720
    • (2003) JAMA , vol.290 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3
  • 6
    • 23444461703 scopus 로고    scopus 로고
    • PAC-Man study collaboration: Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • Harvey S, Harrison DA, Singer M, et al; PAC-Man study collaboration: Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial. Lancet 2005; 366:472-477
    • (2005) Lancet , vol.366 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 7
    • 34547153816 scopus 로고    scopus 로고
    • Trends in the use of the pulmonary artery catheter in the United States, 1993-2004
    • Wiener RS, Welch HG: Trends in the use of the pulmonary artery catheter in the United States, 1993-2004. JAMA 2007; 298:423-429
    • (2007) JAMA , vol.298 , pp. 423-429
    • Wiener, R.S.1    Welch, H.G.2
  • 8
    • 67949105157 scopus 로고    scopus 로고
    • Time series analysis of use patterns for common invasive technologies in critically ill patients
    • Berthiaume LR, Peets AD, Schmidt U, et al: Time series analysis of use patterns for common invasive technologies in critically ill patients. J Crit Care 2009; 24:471.e9-471.e14
    • (2009) J Crit Care , vol.24 , pp. 471e9-471e14
    • Berthiaume, L.R.1    Peets, A.D.2    Schmidt, U.3
  • 9
    • 84859420775 scopus 로고    scopus 로고
    • Cardiac output monitoring devices: An analytic review
    • Porhomayon J, El-Solh A, Papadakos P, et al: Cardiac output monitoring devices: An analytic review. Intern Emerg Med 2012; 7:163-171
    • (2012) Intern Emerg Med , vol.7 , pp. 163-171
    • Porhomayon, J.1    El-Solh, A.2    Papadakos, P.3
  • 10
    • 79251623619 scopus 로고    scopus 로고
    • Methods in pharmacology: Measurement of cardiac output
    • Geerts BF, Aarts LP, Jansen JR: Methods in pharmacology: Measurement of cardiac output. Br J Clin Pharmacol 2011; 71:316-330
    • (2011) Br J Clin Pharmacol , vol.71 , pp. 316-330
    • Geerts, B.F.1    Aarts, L.P.2    Jansen, J.R.3
  • 11
    • 0025318042 scopus 로고
    • Comparing methods of measurement: An alternative approach
    • LaMantia KR, O'Connor T, Barash PG: Comparing methods of measurement: An alternative approach. Anesthesiology 1990; 72:781-783
    • (1990) Anesthesiology , vol.72 , pp. 781-783
    • Lamantia, K.R.1    O'connor, T.2    Barash, P.G.3
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 84655170265 scopus 로고    scopus 로고
    • Agreed statistics: Measurement method comparison
    • Bland JM, Altman DG: Agreed statistics: Measurement method comparison. Anesthesiology 2012; 116:182-185
    • (2012) Anesthesiology , vol.116 , pp. 182-185
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0001830406 scopus 로고
    • The output of the heart in dogs
    • Stewart GN: The output of the heart in dogs. Am J Physiol 1921; 57:27-50
    • (1921) Am J Physiol , vol.57 , pp. 27-50
    • Stewart, G.N.1
  • 15
    • 0017974540 scopus 로고
    • The Stewart-Hamilton equations and the indicator dilution method
    • Profant M, Vyska K, Eckhardt U: The Stewart-Hamilton equations and the indicator dilution method. SIAM J Appl Math 1978; 34:666-675
    • (1978) SIAM J Appl Math , vol.34 , pp. 666-675
    • Profant, M.1    Vyska, K.2    Eckhardt, U.3
  • 16
    • 0027447134 scopus 로고
    • Errors in the measurement of cardiac output by thermodilution
    • Nishikawa T, Dohi S: Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993; 40:142-153
    • (1993) Can J Anaesth , vol.40 , pp. 142-153
    • Nishikawa, T.1    Dohi, S.2
  • 17
    • 0024563766 scopus 로고
    • Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation
    • Cigarroa RG, Lange RA, Williams RH, et al: Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 1989; 86:417-420
    • (1989) Am J Med , vol.86 , pp. 417-420
    • Cigarroa, R.G.1    Lange, R.A.2    Williams, R.H.3
  • 18
    • 0020058784 scopus 로고
    • Overestimation of pediatric cardiac output by thermal indicator loss
    • Maruschak GF, Potter AM, Schauble JF, et al: Overestimation of pediatric cardiac output by thermal indicator loss. Circulation 1982; 65:380-383
    • (1982) Circulation , vol.65 , pp. 380-383
    • Maruschak, G.F.1    Potter, A.M.2    Schauble, J.F.3
  • 19
    • 17644432572 scopus 로고
    • Thermodilution method overestimates low cardiac output in humans
    • van Grondelle A, Ditchey RV, Groves BM, et al: Thermodilution method overestimates low cardiac output in humans. Am J Physiol 1983; 245:H690-H692
    • (1983) Am J Physiol , vol.245 , pp. H690-H692
    • Van Grondelle, A.1    Ditchey, R.V.2    Groves, B.M.3
  • 20
    • 0026628714 scopus 로고
    • Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass
    • Bazaral MG, Petre J, Novoa R: Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass. Anesthesiology 1992; 77:31-37
    • (1992) Anesthesiology , vol.77 , pp. 31-37
    • Bazaral, M.G.1    Petre, J.2    Novoa, R.3
  • 21
    • 0027137477 scopus 로고
    • O'Flaherty D: Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass
    • Latson TW, Whitten CW, O'Flaherty D: Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 1993; 79:1233-1243
    • (1993) Anesthesiology , vol.79 , pp. 1233-1243
    • Latson, T.W.1    Whitten, C.W.2
  • 22
    • 0035075011 scopus 로고    scopus 로고
    • Flow dependency of error in thermodilution measurement of cardiac output during acute tricuspid regurgitation
    • Heerdt PM, Blessios GA, Beach ML, et al: Flow dependency of error in thermodilution measurement of cardiac output during acute tricuspid regurgitation. J Cardiothorac Vasc Anesth 2001; 15:183-187
    • (2001) J Cardiothorac Vasc Anesth , vol.15 , pp. 183-187
    • Heerdt, P.M.1    Blessios, G.A.2    Beach, M.L.3
  • 23
    • 78650944099 scopus 로고    scopus 로고
    • Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig
    • Yang XX, Critchley LA, Joynt GM: Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig. Anesth Analg 2011; 112:70-77
    • (2011) Anesth Analg , vol.112 , pp. 70-77
    • Yang, X.X.1    Critchley, L.A.2    Joynt, G.M.3
  • 24
  • 25
    • 0032435617 scopus 로고    scopus 로고
    • Continuous cardiac output catheters: Delay in in vitro response time after controlled flow changes
    • Aranda M, Mihm FG, Garrett S, et al: Continuous cardiac output catheters: Delay in in vitro response time after controlled flow changes. Anesthesiology 1998; 89:1592-1595
    • (1998) Anesthesiology , vol.89 , pp. 1592-1595
    • Aranda, M.1    Mihm, F.G.2    Garrett, S.3
  • 26
    • 0033512439 scopus 로고    scopus 로고
    • Response time of the Opti-Q continuous cardiac output pulmonary artery catheter in the urgent mode to a step change in cardiac output
    • Goldstein LJ: Response time of the Opti-Q continuous cardiac output pulmonary artery catheter in the urgent mode to a step change in cardiac output. J Clin Monit Comput 1999; 15:435-439
    • (1999) J Clin Monit Comput , vol.15 , pp. 435-439
    • Goldstein, L.J.1
  • 27
    • 0025685462 scopus 로고
    • A multicenter study of physicians' knowledge of the pulmonary artery catheter pulmonary artery catheter study group
    • Iberti TJ, Fischer EP, Leibowitz AB, et al: A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group. JAMA 1990; 264:2928-2932
    • (1990) JAMA , vol.264 , pp. 2928-2932
    • Iberti, T.J.1    Fischer, E.P.2    Leibowitz, A.B.3
  • 28
    • 0021314242 scopus 로고
    • Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standard
    • Schuster AH, Nanda NC: Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standard. Am J Cardiol 1984; 53:257-259
    • (1984) Am J Cardiol , vol.53 , pp. 257-259
    • Schuster, A.H.1    Nanda, N.C.2
  • 29
    • 0021816249 scopus 로고
    • Doppler flowmetry in the lower thoracic aorta. An indirect estimation of cardiac output
    • Smith HJ, Grøttum P, Simonsen S: Doppler flowmetry in the lower thoracic aorta. An indirect estimation of cardiac output. Acta Radiol Diagn (Stockh) 1985; 26:257-263
    • (1985) Acta Radiol Diagn (Stockh) , vol.26 , pp. 257-263
    • Smith, H.J.1    Grøttum, P.2    Simonsen, S.3
  • 30
    • 0025785094 scopus 로고
    • Non-invasive Doppler-derived cardiac output: A validation study comparing this technique with thermodilution and Fick methods
    • Davies JN, Allen DR, Chant AD: Non-invasive Doppler-derived cardiac output: A validation study comparing this technique with thermodilution and Fick methods. Eur J Vasc Surg 1991; 5:497-500
    • (1991) Eur J Vasc Surg , vol.5 , pp. 497-500
    • Davies, J.N.1    Allen, D.R.2    Chant, A.D.3
  • 31
    • 0031871297 scopus 로고    scopus 로고
    • Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler
    • Valtier B, Cholley BP, Belot JP, et al: Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med 1998; 158:77-83
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 77-83
    • Valtier, B.1    Cholley, B.P.2    Belot, J.P.3
  • 32
    • 84925829210 scopus 로고    scopus 로고
    • Oesophageal Doppler Monitor (ODM) guided individualised goal directed fluid management (iGDFM) in surgery-A technical review
    • Accessed February 16, 2013
    • Lowe GD, Chamberlain BM, Philpot EJ, et al: Oesophageal Doppler Monitor (ODM) guided individualised goal directed fluid management (iGDFM) in surgery-A technical review. Deltex Medical Technical Review 2010. Available at: http://www.deltexmedical.com/downloads/ TechnicalReview.pdf. Accessed February 16, 2013
    • (2010) Deltex Medical Technical Review
    • Lowe, G.D.1    Chamberlain, B.M.2    Philpot, E.J.3
  • 33
    • 34547132055 scopus 로고    scopus 로고
    • Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
    • Keren H, Burkhoff D, Squara P: Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 2007; 293:H583-H589
    • (2007) Am J Physiol Heart Circ Physiol , vol.293 , pp. H583-H589
    • Keren, H.1    Burkhoff, D.2    Squara, P.3
  • 34
    • 84859722664 scopus 로고    scopus 로고
    • Non-invasive cardiac output monitoring in neonates using bioreactance: A comparison with echocardiography
    • Weisz DE, Jain A, McNamara PJ, et al: Non-invasive cardiac output monitoring in neonates using bioreactance: A comparison with echocardiography. Neonatology 2012; 102:61-67
    • (2012) Neonatology , vol.102 , pp. 61-67
    • Weisz, D.E.1    Jain, A.2    McNamara, P.J.3
  • 35
    • 41949125848 scopus 로고    scopus 로고
    • Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique
    • Raval NY, Squara P, Cleman M, et al: Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 2008; 22:113-119
    • (2008) J Clin Monit Comput , vol.22 , pp. 113-119
    • Raval, N.Y.1    Squara, P.2    Cleman, M.3
  • 36
    • 67249088798 scopus 로고    scopus 로고
    • Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring
    • Marqué S, Cariou A, Chiche JD, et al: Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care 2009; 13:R73
    • (2009) Crit Care , vol.13 , pp. R73
    • Marqué, S.1    Cariou, A.2    Chiche, J.D.3
  • 37
    • 0028222786 scopus 로고
    • Non-invasive measurement of cardiac output by a carbon dioxide rebreathing method at rest and during exercise
    • Nugent AM, McParland J, McEneaney DJ, et al: Non-invasive measurement of cardiac output by a carbon dioxide rebreathing method at rest and during exercise. Eur Heart J 1994; 15:361-368
    • (1994) Eur Heart J , vol.15 , pp. 361-368
    • Nugent, A.M.1    McParland, J.2    McEneaney, D.J.3
  • 38
    • 0033238015 scopus 로고    scopus 로고
    • Partial CO2 rebreathing cardiac output-Operating principles of the NICO system
    • Jaffe MB: Partial CO2 rebreathing cardiac output-Operating principles of the NICO system. J Clin Monit Comput 1999; 15:387-401
    • (1999) J Clin Monit Comput , vol.15 , pp. 387-401
    • Jaffe, M.B.1
  • 39
    • 0034351171 scopus 로고    scopus 로고
    • Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output
    • Haryadi DG, Orr JA, Kuck K, et al: Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output. J Clin Monit Comput 2000; 16:361-374
    • (2000) J Clin Monit Comput , vol.16 , pp. 361-374
    • Haryadi, D.G.1    Orr, J.A.2    Kuck, K.3
  • 40
    • 29844448951 scopus 로고    scopus 로고
    • Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model
    • Bajorat J, Hofmockel R, Vagts DA, et al: Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol 2006; 23:23-30
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 23-30
    • Bajorat, J.1    Hofmockel, R.2    Vagts, D.A.3
  • 41
    • 17744382825 scopus 로고    scopus 로고
    • The relationship between cardiac output measured by the thermodilution method and that measured by the carbon dioxide rebreathing technique during laparoscopic surgery
    • table of contents
    • Suzuki M, Koda S, Nakamura Y, et al: The relationship between cardiac output measured by the thermodilution method and that measured by the carbon dioxide rebreathing technique during laparoscopic surgery. Anesth Analg 2005; 100:1381-1383, table of contents
    • (2005) Anesth Analg , vol.100 , pp. 1381-1383
    • Suzuki, M.1    Koda, S.2    Nakamura, Y.3
  • 42
    • 0042344943 scopus 로고    scopus 로고
    • Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery
    • Kotake Y, Moriyama K, Innami Y, et al: Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery. Anesthesiology 2003; 99:283-288
    • (2003) Anesthesiology , vol.99 , pp. 283-288
    • Kotake, Y.1    Moriyama, K.2    Innami, Y.3
  • 43
    • 0742287108 scopus 로고    scopus 로고
    • A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation
    • Rocco M, Spadetta G, Morelli A, et al: A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation. Intensive Care Med 2004; 30:82-87
    • (2004) Intensive Care Med , vol.30 , pp. 82-87
    • Rocco, M.1    Spadetta, G.2    Morelli, A.3
  • 44
    • 0036140016 scopus 로고    scopus 로고
    • Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing
    • Tachibana K, Imanaka H, Miyano H, et al: Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing. Anesthesiology 2002; 96:96-102
    • (2002) Anesthesiology , vol.96 , pp. 96-102
    • Tachibana, K.1    Imanaka, H.2    Miyano, H.3
  • 45
    • 0037381750 scopus 로고    scopus 로고
    • Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present
    • Tachibana K, Imanaka H, Takeuchi M, et al: Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present. Anesthesiology 2003; 98:830-837
    • (2003) Anesthesiology , vol.98 , pp. 830-837
    • Tachibana, K.1    Imanaka, H.2    Takeuchi, M.3
  • 46
    • 70350442431 scopus 로고    scopus 로고
    • Pulmonary capillary blood flow and cardiac output measurement by partial carbon dioxide rebreathing in patients with acute respiratory distress syndrome receiving lung protective ventilation
    • Allardet-Servent J, Forel JM, Roch A, et al: Pulmonary capillary blood flow and cardiac output measurement by partial carbon dioxide rebreathing in patients with acute respiratory distress syndrome receiving lung protective ventilation. Anesthesiology 2009; 111:1085-1092
    • (2009) Anesthesiology , vol.111 , pp. 1085-1092
    • Allardet-Servent, J.1    Forel, J.M.2    Roch, A.3
  • 47
    • 13244255445 scopus 로고    scopus 로고
    • Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury
    • Valiatti JL, Amaral JL: Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury. Sao Paulo Med J 2004; 122:233-238
    • (2004) Sao Paulo Med J , vol.122 , pp. 233-238
    • Valiatti, J.L.1    Amaral, J.L.2
  • 48
    • 9244249223 scopus 로고    scopus 로고
    • An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children
    • table of contents
    • Levy RJ, Chiavacci RM, Nicolson SC, et al: An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children. Anesth Analg 2004; 99:1642-1647, table of contents
    • (2004) Anesth Analg , vol.99 , pp. 1642-1647
    • Levy, R.J.1    Chiavacci, R.M.2    Nicolson, S.C.3
  • 49
    • 0033864048 scopus 로고    scopus 로고
    • Clinical evaluation of the noninvasive cardiac output (NICO) monitor in the intensive care unit
    • van Heerden PV, Baker S, Lim SI, et al: Clinical evaluation of the noninvasive cardiac output (NICO) monitor in the intensive care unit. Anaesth Intensive Care 2000; 28:427-430
    • (2000) Anaesth Intensive Care , vol.28 , pp. 427-430
    • Van Heerden, P.V.1    Baker, S.2    Lim, S.I.3
  • 50
    • 80053327347 scopus 로고    scopus 로고
    • Arterial waveform analysis for the anesthesiologist: Past, present, and future concepts
    • Thiele RH, Durieux ME: Arterial waveform analysis for the anesthesiologist: Past, present, and future concepts. Anesth Analg 2011; 113:766-776
    • (2011) Anesth Analg , vol.113 , pp. 766-776
    • Thiele, R.H.1    Durieux, M.E.2
  • 51
    • 0014788560 scopus 로고
    • Estimation of stroke volume in the dog by a pulse contour method
    • Kouchoukos NT, Sheppard LC, McDonald DA: Estimation of stroke volume in the dog by a pulse contour method. Circ Res 1970; 26:611-623
    • (1970) Circ Res , vol.26 , pp. 611-623
    • Kouchoukos, N.T.1    Sheppard, L.C.2    McDonald, D.A.3
  • 52
    • 0033161298 scopus 로고    scopus 로고
    • Fast estimation of arterial vascular parameters for transient and steady beats with application to hemodynamic state under variant gravitational conditions
    • Essler S, Schroeder MJ, Phaniraj V, et al: Fast estimation of arterial vascular parameters for transient and steady beats with application to hemodynamic state under variant gravitational conditions. Ann Biomed Eng 1999; 27:486-497
    • (1999) Ann Biomed Eng , vol.27 , pp. 486-497
    • Essler, S.1    Schroeder, M.J.2    Phaniraj, V.3
  • 53
    • 0002765004 scopus 로고
    • A simple device for the continuous measurement of cardiac output
    • Wesseling KH, de Witt B, Weber AP, et al: A simple device for the continuous measurement of cardiac output. Adv Cardiovasc Phys 1983; 5:16-52
    • (1983) Adv Cardiovasc Phys , vol.5 , pp. 16-52
    • Wesseling, K.H.1    De Witt, B.2    Weber, A.P.3
  • 54
    • 0036152801 scopus 로고    scopus 로고
    • Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
    • Gödje O, Höke K, Goetz AE, et al: Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 2002; 30:52-58
    • (2002) Crit Care Med , vol.30 , pp. 52-58
    • Gödje, O.1    Höke, K.2    Goetz, A.E.3
  • 55
    • 16844383074 scopus 로고    scopus 로고
    • Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock
    • Marx G, Schuerholz T, Sümpelmann R, et al: Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock. Eur J Anaesthesiol 2005; 22:129-134
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 129-134
    • Marx, G.1    Schuerholz, T.2    Sümpelmann, R.3
  • 56
    • 0036020297 scopus 로고    scopus 로고
    • Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle
    • Pauli C, Fakler U, Genz T, et al: Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle. Intensive Care Med 2002; 28:947-952
    • (2002) Intensive Care Med , vol.28 , pp. 947-952
    • Pauli, C.1    Fakler, U.2    Genz, T.3
  • 57
    • 0032734448 scopus 로고    scopus 로고
    • Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
    • Goedje O, Hoeke K, Lichtwarck-Aschoff M, et al: Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution. Crit Care Med 1999; 27:2407-2412
    • (1999) Crit Care Med , vol.27 , pp. 2407-2412
    • Goedje, O.1    Hoeke, K.2    Lichtwarck-Aschoff, M.3
  • 58
    • 34548254794 scopus 로고    scopus 로고
    • Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis
    • Sakka SG, Kozieras J, Thuemer O, et al: Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth 2007; 99:337-342
    • (2007) Br J Anaesth , vol.99 , pp. 337-342
    • Sakka, S.G.1    Kozieras, J.2    Thuemer, O.3
  • 59
    • 0036198399 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
    • Della Rocca G, Costa MG, Pompei L, et al: Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 2002; 88:350-356
    • (2002) Br J Anaesth , vol.88 , pp. 350-356
    • Della Rocca, G.1    Costa, M.G.2    Pompei, L.3
  • 60
    • 38549151697 scopus 로고    scopus 로고
    • Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
    • Hamzaoui O, Monnet X, Richard C, et al: Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008; 36:434-440
    • (2008) Crit Care Med , vol.36 , pp. 434-440
    • Hamzaoui, O.1    Monnet, X.2    Richard, C.3
  • 61
    • 0032817727 scopus 로고    scopus 로고
    • Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
    • Buhre W, Weyland A, Kazmaier S, et al: Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth 1999; 13:437-440
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 437-440
    • Buhre, W.1    Weyland, A.2    Kazmaier, S.3
  • 62
    • 0031714567 scopus 로고    scopus 로고
    • Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting
    • Gust R, Gottschalk A, Bauer H, et al: Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting. J Cardiothorac Vasc Anesth 1998; 12:519-522
    • (1998) J Cardiothorac Vasc Anesth , vol.12 , pp. 519-522
    • Gust, R.1    Gottschalk, A.2    Bauer, H.3
  • 63
    • 8044253807 scopus 로고
    • Thermal dilution curves in the intact animal
    • Goodyer AV, Huvos A, Eckhardt WF, et al: Thermal dilution curves in the intact animal. Circ Res 1959; 7:432-441
    • (1959) Circ Res , vol.7 , pp. 432-441
    • Goodyer, A.V.1    Huvos, A.2    Eckhardt, W.F.3
  • 64
    • 0035064663 scopus 로고    scopus 로고
    • Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb
    • Linton NW, Linton RA: Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth 2001; 86:486-496
    • (2001) Br J Anaesth , vol.86 , pp. 486-496
    • Linton, N.W.1    Linton, R.A.2
  • 65
    • 0033934008 scopus 로고    scopus 로고
    • Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses
    • Linton RA, Young LE, Marlin DJ, et al: Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses. Am J Vet Res 2000; 61:731-737
    • (2000) Am J Vet Res , vol.61 , pp. 731-737
    • Linton, R.A.1    Young, L.E.2    Marlin, D.J.3
  • 66
    • 0030831649 scopus 로고    scopus 로고
    • Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output
    • Kurita T, Morita K, Kato S, et al: Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output. Br J Anaesth 1997; 79:770-775
    • (1997) Br J Anaesth , vol.79 , pp. 770-775
    • Kurita, T.1    Morita, K.2    Kato, S.3
  • 67
    • 0032750908 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurements using a peripheral injection site comparison with central injection technique and thermodilution
    • Kurita T, Morita K, Kato S, et al: Lithium dilution cardiac output measurements using a peripheral injection site comparison with central injection technique and thermodilution. J Clin Monit Comput 1999; 15:279-285
    • (1999) J Clin Monit Comput , vol.15 , pp. 279-285
    • Kurita, T.1    Morita, K.2    Kato, S.3
  • 68
    • 0027219058 scopus 로고
    • A new method of measuring cardiac output in man using lithium dilution
    • Linton RA, Band DM, Haire KM: A new method of measuring cardiac output in man using lithium dilution. Br J Anaesth 1993; 71:262-266
    • (1993) Br J Anaesth , vol.71 , pp. 262-266
    • Linton, R.A.1    Band, D.M.2    Haire, K.M.3
  • 69
    • 38849093827 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs lithium dilution technique
    • Costa MG, Della Rocca G, Chiarandini P, et al: Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs. lithium dilution technique. Intensive Care Med 2008; 34:257-263
    • (2008) Intensive Care Med , vol.34 , pp. 257-263
    • Costa, M.G.1    Della Rocca, G.2    Chiarandini, P.3
  • 70
    • 79960357258 scopus 로고    scopus 로고
    • Validation of cardiac output measurement with the LiDCO pulse contour system in patients with impaired left ventricular function after cardiac surgery
    • Mora B, Ince I, Birkenberg B, et al: Validation of cardiac output measurement with the LiDCO pulse contour system in patients with impaired left ventricular function after cardiac surgery. Anaesthesia 2011; 66:675-681
    • (2011) Anaesthesia , vol.66 , pp. 675-681
    • Mora, B.1    Ince, I.2    Birkenberg, B.3
  • 71
    • 36549051535 scopus 로고    scopus 로고
    • Calculating arterial pressure-based cardiac output using a novel measurement and analysis method
    • Pratt B, Roteliuk L, Hatib F, et al: Calculating arterial pressure-based cardiac output using a novel measurement and analysis method. Biomed Instrum Technol 2007; 41:403-411
    • (2007) Biomed Instrum Technol , vol.41 , pp. 403-411
    • Pratt, B.1    Roteliuk, L.2    Hatib, F.3
  • 72
    • 33846894301 scopus 로고    scopus 로고
    • A pilot assessment of the FloTrac cardiac output monitoring system
    • Opdam HI, Wan L, Bellomo R: A pilot assessment of the FloTrac cardiac output monitoring system. Intensive Care Med 2007; 33:344-349
    • (2007) Intensive Care Med , vol.33 , pp. 344-349
    • Opdam, H.I.1    Wan, L.2    Bellomo, R.3
  • 73
    • 36649018972 scopus 로고    scopus 로고
    • Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements
    • Cannesson M, Attof Y, Rosamel P, et al: Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol 2007; 24:832-839
    • (2007) Eur J Anaesthesiol , vol.24 , pp. 832-839
    • Cannesson, M.1    Attof, Y.2    Rosamel, P.3
  • 74
    • 34648816655 scopus 로고    scopus 로고
    • Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery
    • Breukers RM, Sepehrkhouy S, Spiegelenberg SR, et al: Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. J Cardiothorac Vasc Anesth 2007; 21:632-635
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 632-635
    • Breukers, R.M.1    Sepehrkhouy, S.2    Spiegelenberg, S.R.3
  • 75
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • table of contents
    • Biais M, Nouette-Gaulain K, Cottenceau V, et al: Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008; 106:1480-1486, table of contents
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3
  • 76
    • 80052230646 scopus 로고    scopus 로고
    • Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery
    • Biancofiore G, Critchley LA, Lee A, et al: Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery. Anesth Analg 2011; 113:515-522
    • (2011) Anesth Analg , vol.113 , pp. 515-522
    • Biancofiore, G.1    Critchley, L.A.2    Lee, A.3
  • 77
    • 79954546313 scopus 로고    scopus 로고
    • Comparison of two methods for cardiac output measurement in critically ill patients
    • Saraceni E, Rossi S, Persona P, et al: Comparison of two methods for cardiac output measurement in critically ill patients. Br J Anaesth 2011; 106:690-694
    • (2011) Br J Anaesth , vol.106 , pp. 690-694
    • Saraceni, E.1    Rossi, S.2    Persona, P.3
  • 78
    • 77951628544 scopus 로고    scopus 로고
    • Variations in arterial blood pressure are associated with parallel changes in FlowTrac/ Vigileo-derived cardiac output measurements: A prospective comparison study
    • Eleftheriadis S, Galatoudis Z, Didilis V, et al: Variations in arterial blood pressure are associated with parallel changes in FlowTrac/ Vigileo-derived cardiac output measurements: A prospective comparison study. Crit Care 2009; 13:R179
    • (2009) Crit Care , vol.13 , pp. R179
    • Eleftheriadis, S.1    Galatoudis, Z.2    Didilis, V.3
  • 79
    • 34247551188 scopus 로고    scopus 로고
    • Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
    • Sander M, Spies CD, Grubitzsch H, et al: Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements. Crit Care 2006; 10:R164
    • (2006) Crit Care , vol.10 , pp. R164
    • Sander, M.1    Spies, C.D.2    Grubitzsch, H.3
  • 80
    • 0036342701 scopus 로고    scopus 로고
    • Assessment of cardiac output from systemic arterial pressure in humans
    • Romano SM, Pistolesi M: Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 2002; 30:1834-1841
    • (2002) Crit Care Med , vol.30 , pp. 1834-1841
    • Romano, S.M.1    Pistolesi, M.2
  • 81
    • 66849095760 scopus 로고    scopus 로고
    • Cardiac output by arterial pulse contour: Reliability under hemodynamic derangements
    • Romagnoli S, Romano SM, Bevilacqua S, et al: Cardiac output by arterial pulse contour: Reliability under hemodynamic derangements. Interact Cardiovasc Thorac Surg 2009; 8:642-646
    • (2009) Interact Cardiovasc Thorac Surg , vol.8 , pp. 642-646
    • Romagnoli, S.1    Romano, S.M.2    Bevilacqua, S.3
  • 82
    • 79960547791 scopus 로고    scopus 로고
    • Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients
    • Franchi F, Silvestri R, Cubattoli L, et al: Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients. Br J Anaesth 2011; 107:202-208
    • (2011) Br J Anaesth , vol.107 , pp. 202-208
    • Franchi, F.1    Silvestri, R.2    Cubattoli, L.3
  • 83
    • 48749119302 scopus 로고    scopus 로고
    • Blood flow assessment by arterial pressure wave without external calibration
    • Romano SM, Conti AA, Giglioli C, et al: Blood flow assessment by arterial pressure wave without external calibration. Comput Cardiol 2006; 33:293-296
    • (2006) Comput Cardiol , vol.33 , pp. 293-296
    • Romano, S.M.1    Conti, A.A.2    Giglioli, C.3
  • 84
    • 82255192417 scopus 로고    scopus 로고
    • An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation
    • Scolletta S, Franchi F, Taccone FS, et al: An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation. Anesth Analg 2011; 113:1389-1395
    • (2011) Anesth Analg , vol.113 , pp. 1389-1395
    • Scolletta, S.1    Franchi, F.2    Taccone, F.S.3
  • 85
    • 78549248199 scopus 로고    scopus 로고
    • Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters
    • Hadian M, Kim HK, Severyn DA, et al: Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care 2010; 14:R212
    • (2010) Crit Care , vol.14 , pp. R212
    • Hadian, M.1    Kim, H.K.2    Severyn, D.A.3
  • 86
    • 78651263698 scopus 로고    scopus 로고
    • A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution
    • Cecconi M, Dawson D, Casaretti R, et al: A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution. Minerva Anestesiol 2010; 76:1010-1017
    • (2010) Minerva Anestesiol , vol.76 , pp. 1010-1017
    • Cecconi, M.1    Dawson, D.2    Casaretti, R.3
  • 87
    • 34547699294 scopus 로고    scopus 로고
    • Validation of a new arterial pulse contour-based cardiac output device
    • de Waal EE, Kalkman CJ, Rex S, et al: Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med 2007; 35:1904-1909
    • (2007) Crit Care Med , vol.35 , pp. 1904-1909
    • De Waal, E.E.1    Kalkman, C.J.2    Rex, S.3
  • 88
    • 77953638305 scopus 로고    scopus 로고
    • Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation
    • Krejci V, Vannucci A, Abbas A, et al: Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation. Liver Transpl 2010; 16:773-782
    • (2010) Liver Transpl , vol.16 , pp. 773-782
    • Krejci, V.1    Vannucci, A.2    Abbas, A.3
  • 89
    • 34447642740 scopus 로고    scopus 로고
    • Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability
    • Johansson A, Chew M: Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability. J Clin Monit Comput 2007; 21:237-242
    • (2007) J Clin Monit Comput , vol.21 , pp. 237-242
    • Johansson, A.1    Chew, M.2
  • 90
    • 34250805960 scopus 로고    scopus 로고
    • The reliability of pulse contourderived cardiac output during hemorrhage and after vasopressor administration
    • Bein B, Meybohm P, Cavus E, et al: The reliability of pulse contourderived cardiac output during hemorrhage and after vasopressor administration. Anesth Analg 2007; 105:107-113
    • (2007) Anesth Analg , vol.105 , pp. 107-113
    • Bein, B.1    Meybohm, P.2    Cavus, E.3
  • 91
    • 0033998711 scopus 로고    scopus 로고
    • Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery
    • Zöllner C, Haller M, Weis M, et al: Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth 2000; 14:125-129
    • (2000) J Cardiothorac Vasc Anesth , vol.14 , pp. 125-129
    • Zöllner, C.1    Haller, M.2    Weis, M.3
  • 92
    • 79251542037 scopus 로고    scopus 로고
    • Pulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic volunteers
    • McGrath SP, Ryan KL, Wendelken SM, et al: Pulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic volunteers. Anesth Analg 2011; 112:368-374
    • (2011) Anesth Analg , vol.112 , pp. 368-374
    • McGrath, S.P.1    Ryan, K.L.2    Wendelken, S.M.3
  • 93
    • 82255179474 scopus 로고    scopus 로고
    • Relationship between plethysmographic waveform changes and hemodynamic variables in anesthetized, mechanically ventilated patients undergoing continuous cardiac output monitoring
    • Thiele RH, Colquhoun DA, Patrie J, et al: Relationship between plethysmographic waveform changes and hemodynamic variables in anesthetized, mechanically ventilated patients undergoing continuous cardiac output monitoring. J Cardiothorac Vasc Anesth 2011; 25:1044-1050
    • (2011) J Cardiothorac Vasc Anesth , vol.25 , pp. 1044-1050
    • Thiele, R.H.1    Colquhoun, D.A.2    Patrie, J.3
  • 94
    • 0023429695 scopus 로고
    • Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger
    • Boehmer RD: Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger. J Clin Monit 1987; 3:282-287
    • (1987) J Clin Monit , vol.3 , pp. 282-287
    • Boehmer, R.D.1
  • 95
    • 61949412992 scopus 로고    scopus 로고
    • The reliability of continuous noninvasive finger blood pressure measurement in critically ill children
    • Lemson J, Hofhuizen CM, Schraa O, et al: The reliability of continuous noninvasive finger blood pressure measurement in critically ill children. Anesth Analg 2009; 108:814-821
    • (2009) Anesth Analg , vol.108 , pp. 814-821
    • Lemson, J.1    Hofhuizen, C.M.2    Schraa, O.3
  • 96
    • 77956931912 scopus 로고    scopus 로고
    • Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery
    • Hofhuizen CM, Lemson J, Hemelaar AE, et al: Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery. Br J Anaesth 2010; 105:493-500
    • (2010) Br J Anaesth , vol.105 , pp. 493-500
    • Hofhuizen, C.M.1    Lemson, J.2    Hemelaar, A.E.3
  • 97
    • 84862782626 scopus 로고    scopus 로고
    • Noninvasive continuous arterial blood pressure monitoring with Nexfin
    • Martina JR, Westerhof BE, van Goudoever J, et al: Noninvasive continuous arterial blood pressure monitoring with Nexfin. Anesthesiology 2012; 116:1092-1103
    • (2012) Anesthesiology , vol.116 , pp. 1092-1103
    • Martina, J.R.1    Westerhof, B.E.2    Van Goudoever, J.3
  • 98
    • 0007664690 scopus 로고
    • The determination of the propagation velocity of the arterial pulse wave
    • Hamilton W, Remington J, Dow P: The determination of the propagation velocity of the arterial pulse wave. Am J Physiol 1945; 144:521-535
    • (1945) Am J Physiol , vol.144 , pp. 521-535
    • Hamilton, W.1    Remington, J.2    Dow, P.3
  • 99
    • 0022395726 scopus 로고
    • Arterial pulse wave velocity: A limited index of systemic vascular resistance during normotensive anesthesia in dogs
    • Greene ES, Gerson JI: Arterial pulse wave velocity: A limited index of systemic vascular resistance during normotensive anesthesia in dogs. J Clin Monit 1985; 1:219-226
    • (1985) J Clin Monit , vol.1 , pp. 219-226
    • Greene, E.S.1    Gerson, J.I.2
  • 100
    • 0015129772 scopus 로고
    • Diameter and elasticity of the ascending aorta during infusion of noradrenaline
    • Aars H: Diameter and elasticity of the ascending aorta during infusion of noradrenaline. Acta Physiol Scand 1971; 83:133-138
    • (1971) Acta Physiol Scand , vol.83 , pp. 133-138
    • Aars, H.1
  • 101
    • 20944444823 scopus 로고    scopus 로고
    • A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors
    • Ishihara H, Okawa H, Tanabe K, et al: A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors. J Clin Monit Comput 2004; 18:313-320
    • (2004) J Clin Monit Comput , vol.18 , pp. 313-320
    • Ishihara, H.1    Okawa, H.2    Tanabe, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.