-
1
-
-
0000003630
-
Measurement of cardiac output in anaesthetized animals by a thermodilution method
-
Fegler G: Measurement of cardiac output in anaesthetized animals by a thermodilution method. Q J Exp Physiol Cogn Med Sci 1954; 39:153-164
-
(1954)
Q J Exp Physiol Cogn Med Sci
, vol.39
, pp. 153-164
-
-
Fegler, G.1
-
2
-
-
0014964972
-
Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
-
Swan HJ, Ganz W, Forrester J, et al: Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970; 283:447-451
-
(1970)
N Engl J Med
, vol.283
, pp. 447-451
-
-
Swan, H.J.1
Ganz, W.2
Forrester, J.3
-
3
-
-
0015041424
-
A new technique for measurement of cardiac output by thermodilution in man
-
Ganz W, Donoso R, Marcus HS, et al: A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 1971; 27:392-396
-
(1971)
Am J Cardiol
, vol.27
, pp. 392-396
-
-
Ganz, W.1
Donoso, R.2
Marcus, H.S.3
-
4
-
-
0037413466
-
Canadian Critical Care Clinical Trials Group: A randomized, controlled trial of the use of pulmonaryartery catheters in high-risk surgical patients
-
Sandham JD, Hull RD, Brant RF, et al; Canadian Critical Care Clinical Trials Group: A randomized, controlled trial of the use of pulmonaryartery catheters in high-risk surgical patients. N Engl J Med 2003; 348:5-14
-
(2003)
N Engl J Med
, vol.348
, pp. 5-14
-
-
Sandham, J.D.1
Hull, R.D.2
Brant, R.F.3
-
5
-
-
0345374592
-
French Pulmonary Artery Catheter Study Group: Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial
-
Richard C, Warszawski J, Anguel N, et al; French Pulmonary Artery Catheter Study Group: Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial. JAMA 2003; 290:2713-2720
-
(2003)
JAMA
, vol.290
, pp. 2713-2720
-
-
Richard, C.1
Warszawski, J.2
Anguel, N.3
-
6
-
-
23444461703
-
PAC-Man study collaboration: Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
-
Harvey S, Harrison DA, Singer M, et al; PAC-Man study collaboration: Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial. Lancet 2005; 366:472-477
-
(2005)
Lancet
, vol.366
, pp. 472-477
-
-
Harvey, S.1
Harrison, D.A.2
Singer, M.3
-
7
-
-
34547153816
-
Trends in the use of the pulmonary artery catheter in the United States, 1993-2004
-
Wiener RS, Welch HG: Trends in the use of the pulmonary artery catheter in the United States, 1993-2004. JAMA 2007; 298:423-429
-
(2007)
JAMA
, vol.298
, pp. 423-429
-
-
Wiener, R.S.1
Welch, H.G.2
-
8
-
-
67949105157
-
Time series analysis of use patterns for common invasive technologies in critically ill patients
-
Berthiaume LR, Peets AD, Schmidt U, et al: Time series analysis of use patterns for common invasive technologies in critically ill patients. J Crit Care 2009; 24:471.e9-471.e14
-
(2009)
J Crit Care
, vol.24
, pp. 471e9-471e14
-
-
Berthiaume, L.R.1
Peets, A.D.2
Schmidt, U.3
-
9
-
-
84859420775
-
Cardiac output monitoring devices: An analytic review
-
Porhomayon J, El-Solh A, Papadakos P, et al: Cardiac output monitoring devices: An analytic review. Intern Emerg Med 2012; 7:163-171
-
(2012)
Intern Emerg Med
, vol.7
, pp. 163-171
-
-
Porhomayon, J.1
El-Solh, A.2
Papadakos, P.3
-
11
-
-
0025318042
-
Comparing methods of measurement: An alternative approach
-
LaMantia KR, O'Connor T, Barash PG: Comparing methods of measurement: An alternative approach. Anesthesiology 1990; 72:781-783
-
(1990)
Anesthesiology
, vol.72
, pp. 781-783
-
-
Lamantia, K.R.1
O'connor, T.2
Barash, P.G.3
-
12
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
13
-
-
84655170265
-
Agreed statistics: Measurement method comparison
-
Bland JM, Altman DG: Agreed statistics: Measurement method comparison. Anesthesiology 2012; 116:182-185
-
(2012)
Anesthesiology
, vol.116
, pp. 182-185
-
-
Bland, J.M.1
Altman, D.G.2
-
14
-
-
0001830406
-
The output of the heart in dogs
-
Stewart GN: The output of the heart in dogs. Am J Physiol 1921; 57:27-50
-
(1921)
Am J Physiol
, vol.57
, pp. 27-50
-
-
Stewart, G.N.1
-
15
-
-
0017974540
-
The Stewart-Hamilton equations and the indicator dilution method
-
Profant M, Vyska K, Eckhardt U: The Stewart-Hamilton equations and the indicator dilution method. SIAM J Appl Math 1978; 34:666-675
-
(1978)
SIAM J Appl Math
, vol.34
, pp. 666-675
-
-
Profant, M.1
Vyska, K.2
Eckhardt, U.3
-
16
-
-
0027447134
-
Errors in the measurement of cardiac output by thermodilution
-
Nishikawa T, Dohi S: Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993; 40:142-153
-
(1993)
Can J Anaesth
, vol.40
, pp. 142-153
-
-
Nishikawa, T.1
Dohi, S.2
-
17
-
-
0024563766
-
Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation
-
Cigarroa RG, Lange RA, Williams RH, et al: Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 1989; 86:417-420
-
(1989)
Am J Med
, vol.86
, pp. 417-420
-
-
Cigarroa, R.G.1
Lange, R.A.2
Williams, R.H.3
-
18
-
-
0020058784
-
Overestimation of pediatric cardiac output by thermal indicator loss
-
Maruschak GF, Potter AM, Schauble JF, et al: Overestimation of pediatric cardiac output by thermal indicator loss. Circulation 1982; 65:380-383
-
(1982)
Circulation
, vol.65
, pp. 380-383
-
-
Maruschak, G.F.1
Potter, A.M.2
Schauble, J.F.3
-
19
-
-
17644432572
-
Thermodilution method overestimates low cardiac output in humans
-
van Grondelle A, Ditchey RV, Groves BM, et al: Thermodilution method overestimates low cardiac output in humans. Am J Physiol 1983; 245:H690-H692
-
(1983)
Am J Physiol
, vol.245
, pp. H690-H692
-
-
Van Grondelle, A.1
Ditchey, R.V.2
Groves, B.M.3
-
20
-
-
0026628714
-
Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass
-
Bazaral MG, Petre J, Novoa R: Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass. Anesthesiology 1992; 77:31-37
-
(1992)
Anesthesiology
, vol.77
, pp. 31-37
-
-
Bazaral, M.G.1
Petre, J.2
Novoa, R.3
-
21
-
-
0027137477
-
O'Flaherty D: Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass
-
Latson TW, Whitten CW, O'Flaherty D: Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 1993; 79:1233-1243
-
(1993)
Anesthesiology
, vol.79
, pp. 1233-1243
-
-
Latson, T.W.1
Whitten, C.W.2
-
22
-
-
0035075011
-
Flow dependency of error in thermodilution measurement of cardiac output during acute tricuspid regurgitation
-
Heerdt PM, Blessios GA, Beach ML, et al: Flow dependency of error in thermodilution measurement of cardiac output during acute tricuspid regurgitation. J Cardiothorac Vasc Anesth 2001; 15:183-187
-
(2001)
J Cardiothorac Vasc Anesth
, vol.15
, pp. 183-187
-
-
Heerdt, P.M.1
Blessios, G.A.2
Beach, M.L.3
-
23
-
-
78650944099
-
Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig
-
Yang XX, Critchley LA, Joynt GM: Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig. Anesth Analg 2011; 112:70-77
-
(2011)
Anesth Analg
, vol.112
, pp. 70-77
-
-
Yang, X.X.1
Critchley, L.A.2
Joynt, G.M.3
-
25
-
-
0032435617
-
Continuous cardiac output catheters: Delay in in vitro response time after controlled flow changes
-
Aranda M, Mihm FG, Garrett S, et al: Continuous cardiac output catheters: Delay in in vitro response time after controlled flow changes. Anesthesiology 1998; 89:1592-1595
-
(1998)
Anesthesiology
, vol.89
, pp. 1592-1595
-
-
Aranda, M.1
Mihm, F.G.2
Garrett, S.3
-
26
-
-
0033512439
-
Response time of the Opti-Q continuous cardiac output pulmonary artery catheter in the urgent mode to a step change in cardiac output
-
Goldstein LJ: Response time of the Opti-Q continuous cardiac output pulmonary artery catheter in the urgent mode to a step change in cardiac output. J Clin Monit Comput 1999; 15:435-439
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 435-439
-
-
Goldstein, L.J.1
-
27
-
-
0025685462
-
A multicenter study of physicians' knowledge of the pulmonary artery catheter pulmonary artery catheter study group
-
Iberti TJ, Fischer EP, Leibowitz AB, et al: A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group. JAMA 1990; 264:2928-2932
-
(1990)
JAMA
, vol.264
, pp. 2928-2932
-
-
Iberti, T.J.1
Fischer, E.P.2
Leibowitz, A.B.3
-
28
-
-
0021314242
-
Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standard
-
Schuster AH, Nanda NC: Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standard. Am J Cardiol 1984; 53:257-259
-
(1984)
Am J Cardiol
, vol.53
, pp. 257-259
-
-
Schuster, A.H.1
Nanda, N.C.2
-
29
-
-
0021816249
-
Doppler flowmetry in the lower thoracic aorta. An indirect estimation of cardiac output
-
Smith HJ, Grøttum P, Simonsen S: Doppler flowmetry in the lower thoracic aorta. An indirect estimation of cardiac output. Acta Radiol Diagn (Stockh) 1985; 26:257-263
-
(1985)
Acta Radiol Diagn (Stockh)
, vol.26
, pp. 257-263
-
-
Smith, H.J.1
Grøttum, P.2
Simonsen, S.3
-
30
-
-
0025785094
-
Non-invasive Doppler-derived cardiac output: A validation study comparing this technique with thermodilution and Fick methods
-
Davies JN, Allen DR, Chant AD: Non-invasive Doppler-derived cardiac output: A validation study comparing this technique with thermodilution and Fick methods. Eur J Vasc Surg 1991; 5:497-500
-
(1991)
Eur J Vasc Surg
, vol.5
, pp. 497-500
-
-
Davies, J.N.1
Allen, D.R.2
Chant, A.D.3
-
31
-
-
0031871297
-
Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler
-
Valtier B, Cholley BP, Belot JP, et al: Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med 1998; 158:77-83
-
(1998)
Am J Respir Crit Care Med
, vol.158
, pp. 77-83
-
-
Valtier, B.1
Cholley, B.P.2
Belot, J.P.3
-
32
-
-
84925829210
-
Oesophageal Doppler Monitor (ODM) guided individualised goal directed fluid management (iGDFM) in surgery-A technical review
-
Accessed February 16, 2013
-
Lowe GD, Chamberlain BM, Philpot EJ, et al: Oesophageal Doppler Monitor (ODM) guided individualised goal directed fluid management (iGDFM) in surgery-A technical review. Deltex Medical Technical Review 2010. Available at: http://www.deltexmedical.com/downloads/ TechnicalReview.pdf. Accessed February 16, 2013
-
(2010)
Deltex Medical Technical Review
-
-
Lowe, G.D.1
Chamberlain, B.M.2
Philpot, E.J.3
-
33
-
-
34547132055
-
Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
-
Keren H, Burkhoff D, Squara P: Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 2007; 293:H583-H589
-
(2007)
Am J Physiol Heart Circ Physiol
, vol.293
, pp. H583-H589
-
-
Keren, H.1
Burkhoff, D.2
Squara, P.3
-
34
-
-
84859722664
-
Non-invasive cardiac output monitoring in neonates using bioreactance: A comparison with echocardiography
-
Weisz DE, Jain A, McNamara PJ, et al: Non-invasive cardiac output monitoring in neonates using bioreactance: A comparison with echocardiography. Neonatology 2012; 102:61-67
-
(2012)
Neonatology
, vol.102
, pp. 61-67
-
-
Weisz, D.E.1
Jain, A.2
McNamara, P.J.3
-
35
-
-
41949125848
-
Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique
-
Raval NY, Squara P, Cleman M, et al: Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 2008; 22:113-119
-
(2008)
J Clin Monit Comput
, vol.22
, pp. 113-119
-
-
Raval, N.Y.1
Squara, P.2
Cleman, M.3
-
36
-
-
67249088798
-
Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring
-
Marqué S, Cariou A, Chiche JD, et al: Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care 2009; 13:R73
-
(2009)
Crit Care
, vol.13
, pp. R73
-
-
Marqué, S.1
Cariou, A.2
Chiche, J.D.3
-
37
-
-
0028222786
-
Non-invasive measurement of cardiac output by a carbon dioxide rebreathing method at rest and during exercise
-
Nugent AM, McParland J, McEneaney DJ, et al: Non-invasive measurement of cardiac output by a carbon dioxide rebreathing method at rest and during exercise. Eur Heart J 1994; 15:361-368
-
(1994)
Eur Heart J
, vol.15
, pp. 361-368
-
-
Nugent, A.M.1
McParland, J.2
McEneaney, D.J.3
-
38
-
-
0033238015
-
Partial CO2 rebreathing cardiac output-Operating principles of the NICO system
-
Jaffe MB: Partial CO2 rebreathing cardiac output-Operating principles of the NICO system. J Clin Monit Comput 1999; 15:387-401
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 387-401
-
-
Jaffe, M.B.1
-
39
-
-
0034351171
-
Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output
-
Haryadi DG, Orr JA, Kuck K, et al: Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output. J Clin Monit Comput 2000; 16:361-374
-
(2000)
J Clin Monit Comput
, vol.16
, pp. 361-374
-
-
Haryadi, D.G.1
Orr, J.A.2
Kuck, K.3
-
40
-
-
29844448951
-
Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model
-
Bajorat J, Hofmockel R, Vagts DA, et al: Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol 2006; 23:23-30
-
(2006)
Eur J Anaesthesiol
, vol.23
, pp. 23-30
-
-
Bajorat, J.1
Hofmockel, R.2
Vagts, D.A.3
-
41
-
-
17744382825
-
The relationship between cardiac output measured by the thermodilution method and that measured by the carbon dioxide rebreathing technique during laparoscopic surgery
-
table of contents
-
Suzuki M, Koda S, Nakamura Y, et al: The relationship between cardiac output measured by the thermodilution method and that measured by the carbon dioxide rebreathing technique during laparoscopic surgery. Anesth Analg 2005; 100:1381-1383, table of contents
-
(2005)
Anesth Analg
, vol.100
, pp. 1381-1383
-
-
Suzuki, M.1
Koda, S.2
Nakamura, Y.3
-
42
-
-
0042344943
-
Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery
-
Kotake Y, Moriyama K, Innami Y, et al: Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery. Anesthesiology 2003; 99:283-288
-
(2003)
Anesthesiology
, vol.99
, pp. 283-288
-
-
Kotake, Y.1
Moriyama, K.2
Innami, Y.3
-
43
-
-
0742287108
-
A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation
-
Rocco M, Spadetta G, Morelli A, et al: A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation. Intensive Care Med 2004; 30:82-87
-
(2004)
Intensive Care Med
, vol.30
, pp. 82-87
-
-
Rocco, M.1
Spadetta, G.2
Morelli, A.3
-
44
-
-
0036140016
-
Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing
-
Tachibana K, Imanaka H, Miyano H, et al: Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing. Anesthesiology 2002; 96:96-102
-
(2002)
Anesthesiology
, vol.96
, pp. 96-102
-
-
Tachibana, K.1
Imanaka, H.2
Miyano, H.3
-
45
-
-
0037381750
-
Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present
-
Tachibana K, Imanaka H, Takeuchi M, et al: Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present. Anesthesiology 2003; 98:830-837
-
(2003)
Anesthesiology
, vol.98
, pp. 830-837
-
-
Tachibana, K.1
Imanaka, H.2
Takeuchi, M.3
-
46
-
-
70350442431
-
Pulmonary capillary blood flow and cardiac output measurement by partial carbon dioxide rebreathing in patients with acute respiratory distress syndrome receiving lung protective ventilation
-
Allardet-Servent J, Forel JM, Roch A, et al: Pulmonary capillary blood flow and cardiac output measurement by partial carbon dioxide rebreathing in patients with acute respiratory distress syndrome receiving lung protective ventilation. Anesthesiology 2009; 111:1085-1092
-
(2009)
Anesthesiology
, vol.111
, pp. 1085-1092
-
-
Allardet-Servent, J.1
Forel, J.M.2
Roch, A.3
-
47
-
-
13244255445
-
Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury
-
Valiatti JL, Amaral JL: Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury. Sao Paulo Med J 2004; 122:233-238
-
(2004)
Sao Paulo Med J
, vol.122
, pp. 233-238
-
-
Valiatti, J.L.1
Amaral, J.L.2
-
48
-
-
9244249223
-
An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children
-
table of contents
-
Levy RJ, Chiavacci RM, Nicolson SC, et al: An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children. Anesth Analg 2004; 99:1642-1647, table of contents
-
(2004)
Anesth Analg
, vol.99
, pp. 1642-1647
-
-
Levy, R.J.1
Chiavacci, R.M.2
Nicolson, S.C.3
-
49
-
-
0033864048
-
Clinical evaluation of the noninvasive cardiac output (NICO) monitor in the intensive care unit
-
van Heerden PV, Baker S, Lim SI, et al: Clinical evaluation of the noninvasive cardiac output (NICO) monitor in the intensive care unit. Anaesth Intensive Care 2000; 28:427-430
-
(2000)
Anaesth Intensive Care
, vol.28
, pp. 427-430
-
-
Van Heerden, P.V.1
Baker, S.2
Lim, S.I.3
-
50
-
-
80053327347
-
Arterial waveform analysis for the anesthesiologist: Past, present, and future concepts
-
Thiele RH, Durieux ME: Arterial waveform analysis for the anesthesiologist: Past, present, and future concepts. Anesth Analg 2011; 113:766-776
-
(2011)
Anesth Analg
, vol.113
, pp. 766-776
-
-
Thiele, R.H.1
Durieux, M.E.2
-
51
-
-
0014788560
-
Estimation of stroke volume in the dog by a pulse contour method
-
Kouchoukos NT, Sheppard LC, McDonald DA: Estimation of stroke volume in the dog by a pulse contour method. Circ Res 1970; 26:611-623
-
(1970)
Circ Res
, vol.26
, pp. 611-623
-
-
Kouchoukos, N.T.1
Sheppard, L.C.2
McDonald, D.A.3
-
52
-
-
0033161298
-
Fast estimation of arterial vascular parameters for transient and steady beats with application to hemodynamic state under variant gravitational conditions
-
Essler S, Schroeder MJ, Phaniraj V, et al: Fast estimation of arterial vascular parameters for transient and steady beats with application to hemodynamic state under variant gravitational conditions. Ann Biomed Eng 1999; 27:486-497
-
(1999)
Ann Biomed Eng
, vol.27
, pp. 486-497
-
-
Essler, S.1
Schroeder, M.J.2
Phaniraj, V.3
-
53
-
-
0002765004
-
A simple device for the continuous measurement of cardiac output
-
Wesseling KH, de Witt B, Weber AP, et al: A simple device for the continuous measurement of cardiac output. Adv Cardiovasc Phys 1983; 5:16-52
-
(1983)
Adv Cardiovasc Phys
, vol.5
, pp. 16-52
-
-
Wesseling, K.H.1
De Witt, B.2
Weber, A.P.3
-
54
-
-
0036152801
-
Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
-
Gödje O, Höke K, Goetz AE, et al: Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 2002; 30:52-58
-
(2002)
Crit Care Med
, vol.30
, pp. 52-58
-
-
Gödje, O.1
Höke, K.2
Goetz, A.E.3
-
55
-
-
16844383074
-
Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock
-
Marx G, Schuerholz T, Sümpelmann R, et al: Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock. Eur J Anaesthesiol 2005; 22:129-134
-
(2005)
Eur J Anaesthesiol
, vol.22
, pp. 129-134
-
-
Marx, G.1
Schuerholz, T.2
Sümpelmann, R.3
-
56
-
-
0036020297
-
Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle
-
Pauli C, Fakler U, Genz T, et al: Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle. Intensive Care Med 2002; 28:947-952
-
(2002)
Intensive Care Med
, vol.28
, pp. 947-952
-
-
Pauli, C.1
Fakler, U.2
Genz, T.3
-
57
-
-
0032734448
-
Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
-
Goedje O, Hoeke K, Lichtwarck-Aschoff M, et al: Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution. Crit Care Med 1999; 27:2407-2412
-
(1999)
Crit Care Med
, vol.27
, pp. 2407-2412
-
-
Goedje, O.1
Hoeke, K.2
Lichtwarck-Aschoff, M.3
-
58
-
-
34548254794
-
Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis
-
Sakka SG, Kozieras J, Thuemer O, et al: Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth 2007; 99:337-342
-
(2007)
Br J Anaesth
, vol.99
, pp. 337-342
-
-
Sakka, S.G.1
Kozieras, J.2
Thuemer, O.3
-
59
-
-
0036198399
-
Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
-
Della Rocca G, Costa MG, Pompei L, et al: Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 2002; 88:350-356
-
(2002)
Br J Anaesth
, vol.88
, pp. 350-356
-
-
Della Rocca, G.1
Costa, M.G.2
Pompei, L.3
-
60
-
-
38549151697
-
Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
-
Hamzaoui O, Monnet X, Richard C, et al: Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008; 36:434-440
-
(2008)
Crit Care Med
, vol.36
, pp. 434-440
-
-
Hamzaoui, O.1
Monnet, X.2
Richard, C.3
-
61
-
-
0032817727
-
Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
-
Buhre W, Weyland A, Kazmaier S, et al: Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth 1999; 13:437-440
-
(1999)
J Cardiothorac Vasc Anesth
, vol.13
, pp. 437-440
-
-
Buhre, W.1
Weyland, A.2
Kazmaier, S.3
-
62
-
-
0031714567
-
Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting
-
Gust R, Gottschalk A, Bauer H, et al: Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting. J Cardiothorac Vasc Anesth 1998; 12:519-522
-
(1998)
J Cardiothorac Vasc Anesth
, vol.12
, pp. 519-522
-
-
Gust, R.1
Gottschalk, A.2
Bauer, H.3
-
63
-
-
8044253807
-
Thermal dilution curves in the intact animal
-
Goodyer AV, Huvos A, Eckhardt WF, et al: Thermal dilution curves in the intact animal. Circ Res 1959; 7:432-441
-
(1959)
Circ Res
, vol.7
, pp. 432-441
-
-
Goodyer, A.V.1
Huvos, A.2
Eckhardt, W.F.3
-
64
-
-
0035064663
-
Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb
-
Linton NW, Linton RA: Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth 2001; 86:486-496
-
(2001)
Br J Anaesth
, vol.86
, pp. 486-496
-
-
Linton, N.W.1
Linton, R.A.2
-
65
-
-
0033934008
-
Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses
-
Linton RA, Young LE, Marlin DJ, et al: Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses. Am J Vet Res 2000; 61:731-737
-
(2000)
Am J Vet Res
, vol.61
, pp. 731-737
-
-
Linton, R.A.1
Young, L.E.2
Marlin, D.J.3
-
66
-
-
0030831649
-
Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output
-
Kurita T, Morita K, Kato S, et al: Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output. Br J Anaesth 1997; 79:770-775
-
(1997)
Br J Anaesth
, vol.79
, pp. 770-775
-
-
Kurita, T.1
Morita, K.2
Kato, S.3
-
67
-
-
0032750908
-
Lithium dilution cardiac output measurements using a peripheral injection site comparison with central injection technique and thermodilution
-
Kurita T, Morita K, Kato S, et al: Lithium dilution cardiac output measurements using a peripheral injection site comparison with central injection technique and thermodilution. J Clin Monit Comput 1999; 15:279-285
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 279-285
-
-
Kurita, T.1
Morita, K.2
Kato, S.3
-
68
-
-
0027219058
-
A new method of measuring cardiac output in man using lithium dilution
-
Linton RA, Band DM, Haire KM: A new method of measuring cardiac output in man using lithium dilution. Br J Anaesth 1993; 71:262-266
-
(1993)
Br J Anaesth
, vol.71
, pp. 262-266
-
-
Linton, R.A.1
Band, D.M.2
Haire, K.M.3
-
69
-
-
38849093827
-
Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs lithium dilution technique
-
Costa MG, Della Rocca G, Chiarandini P, et al: Continuous and intermittent cardiac output measurement in hyperdynamic conditions: Pulmonary artery catheter vs. lithium dilution technique. Intensive Care Med 2008; 34:257-263
-
(2008)
Intensive Care Med
, vol.34
, pp. 257-263
-
-
Costa, M.G.1
Della Rocca, G.2
Chiarandini, P.3
-
70
-
-
79960357258
-
Validation of cardiac output measurement with the LiDCO pulse contour system in patients with impaired left ventricular function after cardiac surgery
-
Mora B, Ince I, Birkenberg B, et al: Validation of cardiac output measurement with the LiDCO pulse contour system in patients with impaired left ventricular function after cardiac surgery. Anaesthesia 2011; 66:675-681
-
(2011)
Anaesthesia
, vol.66
, pp. 675-681
-
-
Mora, B.1
Ince, I.2
Birkenberg, B.3
-
71
-
-
36549051535
-
Calculating arterial pressure-based cardiac output using a novel measurement and analysis method
-
Pratt B, Roteliuk L, Hatib F, et al: Calculating arterial pressure-based cardiac output using a novel measurement and analysis method. Biomed Instrum Technol 2007; 41:403-411
-
(2007)
Biomed Instrum Technol
, vol.41
, pp. 403-411
-
-
Pratt, B.1
Roteliuk, L.2
Hatib, F.3
-
72
-
-
33846894301
-
A pilot assessment of the FloTrac cardiac output monitoring system
-
Opdam HI, Wan L, Bellomo R: A pilot assessment of the FloTrac cardiac output monitoring system. Intensive Care Med 2007; 33:344-349
-
(2007)
Intensive Care Med
, vol.33
, pp. 344-349
-
-
Opdam, H.I.1
Wan, L.2
Bellomo, R.3
-
73
-
-
36649018972
-
Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements
-
Cannesson M, Attof Y, Rosamel P, et al: Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol 2007; 24:832-839
-
(2007)
Eur J Anaesthesiol
, vol.24
, pp. 832-839
-
-
Cannesson, M.1
Attof, Y.2
Rosamel, P.3
-
74
-
-
34648816655
-
Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery
-
Breukers RM, Sepehrkhouy S, Spiegelenberg SR, et al: Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. J Cardiothorac Vasc Anesth 2007; 21:632-635
-
(2007)
J Cardiothorac Vasc Anesth
, vol.21
, pp. 632-635
-
-
Breukers, R.M.1
Sepehrkhouy, S.2
Spiegelenberg, S.R.3
-
75
-
-
42449103530
-
Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
-
table of contents
-
Biais M, Nouette-Gaulain K, Cottenceau V, et al: Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008; 106:1480-1486, table of contents
-
(2008)
Anesth Analg
, vol.106
, pp. 1480-1486
-
-
Biais, M.1
Nouette-Gaulain, K.2
Cottenceau, V.3
-
76
-
-
80052230646
-
Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery
-
Biancofiore G, Critchley LA, Lee A, et al: Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery. Anesth Analg 2011; 113:515-522
-
(2011)
Anesth Analg
, vol.113
, pp. 515-522
-
-
Biancofiore, G.1
Critchley, L.A.2
Lee, A.3
-
77
-
-
79954546313
-
Comparison of two methods for cardiac output measurement in critically ill patients
-
Saraceni E, Rossi S, Persona P, et al: Comparison of two methods for cardiac output measurement in critically ill patients. Br J Anaesth 2011; 106:690-694
-
(2011)
Br J Anaesth
, vol.106
, pp. 690-694
-
-
Saraceni, E.1
Rossi, S.2
Persona, P.3
-
78
-
-
77951628544
-
Variations in arterial blood pressure are associated with parallel changes in FlowTrac/ Vigileo-derived cardiac output measurements: A prospective comparison study
-
Eleftheriadis S, Galatoudis Z, Didilis V, et al: Variations in arterial blood pressure are associated with parallel changes in FlowTrac/ Vigileo-derived cardiac output measurements: A prospective comparison study. Crit Care 2009; 13:R179
-
(2009)
Crit Care
, vol.13
, pp. R179
-
-
Eleftheriadis, S.1
Galatoudis, Z.2
Didilis, V.3
-
79
-
-
34247551188
-
Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
-
Sander M, Spies CD, Grubitzsch H, et al: Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements. Crit Care 2006; 10:R164
-
(2006)
Crit Care
, vol.10
, pp. R164
-
-
Sander, M.1
Spies, C.D.2
Grubitzsch, H.3
-
80
-
-
0036342701
-
Assessment of cardiac output from systemic arterial pressure in humans
-
Romano SM, Pistolesi M: Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 2002; 30:1834-1841
-
(2002)
Crit Care Med
, vol.30
, pp. 1834-1841
-
-
Romano, S.M.1
Pistolesi, M.2
-
81
-
-
66849095760
-
Cardiac output by arterial pulse contour: Reliability under hemodynamic derangements
-
Romagnoli S, Romano SM, Bevilacqua S, et al: Cardiac output by arterial pulse contour: Reliability under hemodynamic derangements. Interact Cardiovasc Thorac Surg 2009; 8:642-646
-
(2009)
Interact Cardiovasc Thorac Surg
, vol.8
, pp. 642-646
-
-
Romagnoli, S.1
Romano, S.M.2
Bevilacqua, S.3
-
82
-
-
79960547791
-
Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients
-
Franchi F, Silvestri R, Cubattoli L, et al: Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients. Br J Anaesth 2011; 107:202-208
-
(2011)
Br J Anaesth
, vol.107
, pp. 202-208
-
-
Franchi, F.1
Silvestri, R.2
Cubattoli, L.3
-
83
-
-
48749119302
-
Blood flow assessment by arterial pressure wave without external calibration
-
Romano SM, Conti AA, Giglioli C, et al: Blood flow assessment by arterial pressure wave without external calibration. Comput Cardiol 2006; 33:293-296
-
(2006)
Comput Cardiol
, vol.33
, pp. 293-296
-
-
Romano, S.M.1
Conti, A.A.2
Giglioli, C.3
-
84
-
-
82255192417
-
An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation
-
Scolletta S, Franchi F, Taccone FS, et al: An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation. Anesth Analg 2011; 113:1389-1395
-
(2011)
Anesth Analg
, vol.113
, pp. 1389-1395
-
-
Scolletta, S.1
Franchi, F.2
Taccone, F.S.3
-
85
-
-
78549248199
-
Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters
-
Hadian M, Kim HK, Severyn DA, et al: Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care 2010; 14:R212
-
(2010)
Crit Care
, vol.14
, pp. R212
-
-
Hadian, M.1
Kim, H.K.2
Severyn, D.A.3
-
86
-
-
78651263698
-
A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution
-
Cecconi M, Dawson D, Casaretti R, et al: A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution. Minerva Anestesiol 2010; 76:1010-1017
-
(2010)
Minerva Anestesiol
, vol.76
, pp. 1010-1017
-
-
Cecconi, M.1
Dawson, D.2
Casaretti, R.3
-
87
-
-
34547699294
-
Validation of a new arterial pulse contour-based cardiac output device
-
de Waal EE, Kalkman CJ, Rex S, et al: Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med 2007; 35:1904-1909
-
(2007)
Crit Care Med
, vol.35
, pp. 1904-1909
-
-
De Waal, E.E.1
Kalkman, C.J.2
Rex, S.3
-
88
-
-
77953638305
-
Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation
-
Krejci V, Vannucci A, Abbas A, et al: Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation. Liver Transpl 2010; 16:773-782
-
(2010)
Liver Transpl
, vol.16
, pp. 773-782
-
-
Krejci, V.1
Vannucci, A.2
Abbas, A.3
-
89
-
-
34447642740
-
Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability
-
Johansson A, Chew M: Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability. J Clin Monit Comput 2007; 21:237-242
-
(2007)
J Clin Monit Comput
, vol.21
, pp. 237-242
-
-
Johansson, A.1
Chew, M.2
-
90
-
-
34250805960
-
The reliability of pulse contourderived cardiac output during hemorrhage and after vasopressor administration
-
Bein B, Meybohm P, Cavus E, et al: The reliability of pulse contourderived cardiac output during hemorrhage and after vasopressor administration. Anesth Analg 2007; 105:107-113
-
(2007)
Anesth Analg
, vol.105
, pp. 107-113
-
-
Bein, B.1
Meybohm, P.2
Cavus, E.3
-
91
-
-
0033998711
-
Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery
-
Zöllner C, Haller M, Weis M, et al: Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth 2000; 14:125-129
-
(2000)
J Cardiothorac Vasc Anesth
, vol.14
, pp. 125-129
-
-
Zöllner, C.1
Haller, M.2
Weis, M.3
-
92
-
-
79251542037
-
Pulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic volunteers
-
McGrath SP, Ryan KL, Wendelken SM, et al: Pulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic volunteers. Anesth Analg 2011; 112:368-374
-
(2011)
Anesth Analg
, vol.112
, pp. 368-374
-
-
McGrath, S.P.1
Ryan, K.L.2
Wendelken, S.M.3
-
93
-
-
82255179474
-
Relationship between plethysmographic waveform changes and hemodynamic variables in anesthetized, mechanically ventilated patients undergoing continuous cardiac output monitoring
-
Thiele RH, Colquhoun DA, Patrie J, et al: Relationship between plethysmographic waveform changes and hemodynamic variables in anesthetized, mechanically ventilated patients undergoing continuous cardiac output monitoring. J Cardiothorac Vasc Anesth 2011; 25:1044-1050
-
(2011)
J Cardiothorac Vasc Anesth
, vol.25
, pp. 1044-1050
-
-
Thiele, R.H.1
Colquhoun, D.A.2
Patrie, J.3
-
94
-
-
0023429695
-
Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger
-
Boehmer RD: Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger. J Clin Monit 1987; 3:282-287
-
(1987)
J Clin Monit
, vol.3
, pp. 282-287
-
-
Boehmer, R.D.1
-
95
-
-
61949412992
-
The reliability of continuous noninvasive finger blood pressure measurement in critically ill children
-
Lemson J, Hofhuizen CM, Schraa O, et al: The reliability of continuous noninvasive finger blood pressure measurement in critically ill children. Anesth Analg 2009; 108:814-821
-
(2009)
Anesth Analg
, vol.108
, pp. 814-821
-
-
Lemson, J.1
Hofhuizen, C.M.2
Schraa, O.3
-
96
-
-
77956931912
-
Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery
-
Hofhuizen CM, Lemson J, Hemelaar AE, et al: Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery. Br J Anaesth 2010; 105:493-500
-
(2010)
Br J Anaesth
, vol.105
, pp. 493-500
-
-
Hofhuizen, C.M.1
Lemson, J.2
Hemelaar, A.E.3
-
97
-
-
84862782626
-
Noninvasive continuous arterial blood pressure monitoring with Nexfin
-
Martina JR, Westerhof BE, van Goudoever J, et al: Noninvasive continuous arterial blood pressure monitoring with Nexfin. Anesthesiology 2012; 116:1092-1103
-
(2012)
Anesthesiology
, vol.116
, pp. 1092-1103
-
-
Martina, J.R.1
Westerhof, B.E.2
Van Goudoever, J.3
-
98
-
-
0007664690
-
The determination of the propagation velocity of the arterial pulse wave
-
Hamilton W, Remington J, Dow P: The determination of the propagation velocity of the arterial pulse wave. Am J Physiol 1945; 144:521-535
-
(1945)
Am J Physiol
, vol.144
, pp. 521-535
-
-
Hamilton, W.1
Remington, J.2
Dow, P.3
-
99
-
-
0022395726
-
Arterial pulse wave velocity: A limited index of systemic vascular resistance during normotensive anesthesia in dogs
-
Greene ES, Gerson JI: Arterial pulse wave velocity: A limited index of systemic vascular resistance during normotensive anesthesia in dogs. J Clin Monit 1985; 1:219-226
-
(1985)
J Clin Monit
, vol.1
, pp. 219-226
-
-
Greene, E.S.1
Gerson, J.I.2
-
100
-
-
0015129772
-
Diameter and elasticity of the ascending aorta during infusion of noradrenaline
-
Aars H: Diameter and elasticity of the ascending aorta during infusion of noradrenaline. Acta Physiol Scand 1971; 83:133-138
-
(1971)
Acta Physiol Scand
, vol.83
, pp. 133-138
-
-
Aars, H.1
-
101
-
-
20944444823
-
A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors
-
Ishihara H, Okawa H, Tanabe K, et al: A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors. J Clin Monit Comput 2004; 18:313-320
-
(2004)
J Clin Monit Comput
, vol.18
, pp. 313-320
-
-
Ishihara, H.1
Okawa, H.2
Tanabe, K.3
|