메뉴 건너뛰기




Volumn 100, Issue 5, 2005, Pages 1381-1383

The relationship between cardiac output measured by the thermodilution method and that measured by the carbon dioxide rebreathing technique during laparoscopic surgery

Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE; ISOFLURANE; MEPIVACAINE; NITROUS OXIDE; OXYGEN; THIOPENTAL; VECURONIUM;

EID: 17744382825     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ANE.0000148697.28380.D5     Document Type: Article
Times cited : (10)

References (9)
  • 1
    • 0036140016 scopus 로고    scopus 로고
    • Effect of ventilatory settings on the accuracy of cardiac output measurement using partial CO2 rebreathing
    • Tachibana K, Imanaka H, Miyano H, et al. Effect of ventilatory settings on the accuracy of cardiac output measurement using partial CO2 rebreathing. Anesthesiology 2002;96:96-102.
    • (2002) Anesthesiology , vol.96 , pp. 96-102
    • Tachibana, K.1    Imanaka, H.2    Miyano, H.3
  • 2
    • 0036193940 scopus 로고    scopus 로고
    • Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients
    • Odenstedt H, Stenqvist O, Lundin S. Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients. Acta Anaesthesiol Scand 2002;46:152-9.
    • (2002) Acta Anaesthesiol Scand , vol.46 , pp. 152-159
    • Odenstedt, H.1    Stenqvist, O.2    Lundin, S.3
  • 3
    • 0033031036 scopus 로고    scopus 로고
    • Continuous thermodilution cardiac output: Clinical validation against a reference technique of known accuracy
    • Schmid ER, Schmidlin D, Tornic M, Seifert B. Continuous thermodilution cardiac output: clinical validation against a reference technique of known accuracy. Intensive Care Med 1999;25: 166-72.
    • (1999) Intensive Care Med , vol.25 , pp. 166-172
    • Schmid, E.R.1    Schmidlin, D.2    Tornic, M.3    Seifert, B.4
  • 4
    • 0035132072 scopus 로고    scopus 로고
    • Non-invasive cardiac output determination: Comparison of a new partial-rebreathing technique with thermodilution
    • Binder JC, Parkin WG. Non-invasive cardiac output determination: comparison of a new partial-rebreathing technique with thermodilution. Anaesth Intensive Care 2001;29:19-23.
    • (2001) Anaesth Intensive Care , vol.29 , pp. 19-23
    • Binder, J.C.1    Parkin, W.G.2
  • 5
    • 0028072122 scopus 로고
    • Non-invasive measurement of cardiac output in patients with acute lung injury using the carbon dioxide rebreathing method
    • Neviere R, Mathieu D, Riou Y, et al. Non-invasive measurement of cardiac output in patients with acute lung injury using the carbon dioxide rebreathing method. Clin Intensive Care 1994;5:172-5.
    • (1994) Clin Intensive Care , vol.5 , pp. 172-175
    • Neviere, R.1    Mathieu, D.2    Riou, Y.3
  • 6
    • 0021710225 scopus 로고
    • A reassessment of the validity of the isoshunt graph
    • Lawler PG, Nunn JF. A reassessment of the validity of the isoshunt graph. Br J Anaesth 1984;56:1325-35.
    • (1984) Br J Anaesth , vol.56 , pp. 1325-1335
    • Lawler, P.G.1    Nunn, J.F.2
  • 7
    • 0034963214 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output
    • Nilsson LB, Eldrut N, Berthelsen PG. Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output. Acta Anaesthesiol Scand 2001;45:680-5.
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 680-685
    • Nilsson, L.B.1    Eldrut, N.2    Berthelsen, P.G.3
  • 8
    • 0020702049 scopus 로고
    • The reliability of the carbon dioxide-rebreathing, indirect Fick method of cardiac output determination in patients with pulmonary disease
    • Stewart RI, Lewis CM. The reliability of the carbon dioxide-rebreathing, indirect Fick method of cardiac output determination in patients with pulmonary disease. Clin Sci 1983;64:289-93.
    • (1983) Clin Sci , vol.64 , pp. 289-293
    • Stewart, R.I.1    Lewis, C.M.2
  • 9
    • 0023922453 scopus 로고
    • Accuracy of an indirect carbon dioxide Fick method in determination of the cardiac output in critically ill mechanically ventilated patients
    • Blanch L, Fernandez R, Benito S, et al. Accuracy of an indirect carbon dioxide Fick method in determination of the cardiac output in critically ill mechanically ventilated patients. Intensive Care Med 1988;14:131-5.
    • (1988) Intensive Care Med , vol.14 , pp. 131-135
    • Blanch, L.1    Fernandez, R.2    Benito, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.