메뉴 건너뛰기




Volumn 8, Issue 6, 2009, Pages 642-646

Cardiac output by arterial pulse contour: Reliability under hemodynamic derangements

Author keywords

Arterial pulse contour; Cardiac output; Most Care ; Pressure recording analytical method (PRAM)

Indexed keywords

ARGIPRESSIN; DOBUTAMINE;

EID: 66849095760     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2008.200451     Document Type: Article
Times cited : (29)

References (15)
  • 1
    • 33751109052 scopus 로고    scopus 로고
    • Hemodynamic monitoring over the past 10 years
    • DOI 10.1186/cc3997
    • Pinsky MR. Hemodynamic monitoring over the past 10 years. Crit Care 2006;10:117. (Pubitemid 47079828)
    • (2006) Critical Care , vol.10 , Issue.1 , pp. 117
    • Pinsky, M.R.1
  • 2
  • 3
    • 18344363998 scopus 로고    scopus 로고
    • Let us use the pulmonary artery catheter correctly and only when we need it
    • DOI 10.1097/01.CCM.0000163238.64905.56
    • Pinsky MR, Vincent JL. Let us use the pulmonary artery catheter correctly and only when we need it. Crit Care Med 2005;33:1119-1122. (Pubitemid 40638189)
    • (2005) Critical Care Medicine , vol.33 , Issue.5 , pp. 1119-1122
    • Pinsky, M.R.1    Vincent, J.-L.2
  • 5
    • 26944486636 scopus 로고    scopus 로고
    • Noninvasive techniques for measurements of cardiac output
    • DOI 10.1097/01.ccx.0000176698.51456.5a
    • Cholley BP, Payen D. Non-invasive techniques for measurements of cardiac output. Curr Opin Crit Care 2005;11:424-429. (Pubitemid 41482697)
    • (2005) Current Opinion in Critical Care , vol.11 , Issue.5 , pp. 424-429
    • Cholley, B.P.1    Payen, D.2
  • 6
    • 0036342701 scopus 로고    scopus 로고
    • Assessment of cardiac output from systemic arterial pressure in humans
    • Romano SM, Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 2002;30:1834-1841. (Pubitemid 34879600)
    • (2002) Critical Care Medicine , vol.30 , Issue.8 , pp. 1834-1841
    • Romano, S.M.1    Pistolesi, M.2
  • 7
    • 43549100903 scopus 로고    scopus 로고
    • Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiography
    • Calamandrei M, Mirabile L, Muschetta S, Gensini GF, De Simone L, Romano SM. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography. Pediatr Crit Care 2008;9:310-312.
    • (2008) Pediatr Crit Care , vol.9 , pp. 310-312
    • Calamandrei, M.1    Mirabile, L.2    Muschetta, S.3    Gensini, G.F.4    De Simone, L.5    Romano, S.M.6
  • 8
    • 23844520689 scopus 로고    scopus 로고
    • Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states
    • DOI 10.1093/bja/aei154
    • Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P. Pressure recording analytical method (PRAM) for measurement of cardiac output during various hemodynamic states. Br J Anaesth 2005;95:159-165. (Pubitemid 41487138)
    • (2005) British Journal of Anaesthesia , vol.95 , Issue.2 PAPER , pp. 159-165
    • Scolletta, S.1    Romano, S.M.2    Biagioli, B.3    Capannini, G.4    Giomarelli, P.5
  • 9
    • 0345131662 scopus 로고    scopus 로고
    • Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: A comparison to thermodilution
    • DOI 10.1097/00000542-199808000-00010
    • Perrino AC, Harris SN, Luther MA. Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution. Anesthesiology 1998;89:350-357. (Pubitemid 28373423)
    • (1998) Anesthesiology , vol.89 , Issue.2 , pp. 350-357
    • Perrino Jr., A.C.1    Harris, S.N.2    Luther, M.A.3
  • 10
    • 23344442308 scopus 로고    scopus 로고
    • A hemoglobin-based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in a moderate severity hemorrhagic shock swine model with delayed evacuation
    • DOI 10.1016/j.resuscitation.2005.03.019, PII S0300957205001899
    • Philbin N, Rice J, Gurney J, McGuin G, Arnaud F, Dong F, Johnson T, Flournoy WS, Ahlers S, Pearce LB, McCarron R, Freilich D. A hemoglobin-based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in a moderate severity hemorrhagic shock swine model with delayed evacuation. Resuscitation 2005;66:367-368. (Pubitemid 41219387)
    • (2005) Resuscitation , vol.66 , Issue.3 , pp. 367-378
    • Philbin, N.1    Rice, J.2    Gurney, J.3    McGwin, G.4    Arnaud, F.5    Dong, F.6    Johnson, T.7    Flournoy, W.S.8    Ahlers, S.9    Pearce, L.B.10    McCarron, R.11    Freilich, D.12
  • 11
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Statistician 1983;32:307-317.
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 12
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LAH, Critchley JAJH. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999;15:85-91. (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 13
    • 34249000391 scopus 로고    scopus 로고
    • Methodologies for assessing agreement between two methods of clinical measurement: Are we as good as we think are?
    • Cecconi M, Grounds M, Rhodes A. Methodologies for assessing agreement between two methods of clinical measurement: are we as good as we think are? Curr Opin Crit Care 2007;13:294-296.
    • (2007) Curr Opin Crit Care , vol.13 , pp. 294-296
    • Cecconi, M.1    Grounds, M.2    Rhodes, A.3
  • 14
    • 0036385496 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and Fick cardiac output in critically ill patients
    • Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ. Lack of agreement between thermodilution and Fick cardiac output in critically ill patients. Chest 2002;122:990-997.
    • (2002) Chest , vol.122 , pp. 990-997
    • Dhingra, V.K.1    Fenwick, J.C.2    Walley, K.R.3    Chittock, D.R.4    Ronco, J.J.5
  • 15
    • 33846894301 scopus 로고    scopus 로고
    • A pilot assessment of the FloTrac™ cardiac output monitoring system
    • DOI 10.1007/s00134-006-0410-4
    • Opdam HE, Wan L, Bellomo R. A pilot assessment of the FloTrac™ cardiac output monitoring system. Int Care Med 2007;33:344-349. (Pubitemid 46221243)
    • (2007) Intensive Care Medicine , vol.33 , Issue.2 , pp. 344-349
    • Opdam, H.I.1    Wan, L.2    Bellomo, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.