Meta-analysis of hemodynamic optimization in high-risk patients
-
Kern JW, Shoemaker WC. Meta-analysis of hemodynamic optimization in high-risk patients. Crit Care Med 2002;30: 1686-92.
-
(2002)
Crit Care Med
, vol.30
, pp. 1686-1692
-
-
Kern, J.W.1
Shoemaker, W.C.2
-
2
-
-
33750565925
-
Meta-analysis of hemodynamic optimization: Relationship to methodological quality
-
(London, England)
-
Poeze M, Greve J, Ramsay G. Meta-analysis of hemodynamic optimization: relationship to methodological quality. Critical Care (London, England) 2005;9:R771-9.
-
(2005)
Critical Care
, vol.9
-
-
Poeze, M.1
Greve, J.2
Ramsay, G.3
-
3
-
-
0029153813
-
The thermodilution method for the clinical assessment of cardiac output
-
Jansen JR. The thermodilution method for the clinical assessment of cardiac output. Intensive Care Med 1995;21: 691-7.
-
(1995)
Intensive Care Med
, vol.21
, pp. 691-697
-
-
Jansen, J.R.1
-
5
-
-
0036198399
-
Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
-
Della Rocca G, Costa MG, Pompei L, Coccia C, Pietropaoli P. Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 2002;88:350-6.
-
(2002)
Br J Anaesth
, vol.88
, pp. 350-356
-
-
della Rocca, G.1
Costa, M.G.2
Pompei, L.3
Coccia, C.4
Pietropaoli, P.5
-
6
-
-
48749111644
-
The ability of PiCCO versus LiDCOvariables to detect changes in cardiac index: A prospective clinical study
-
Donati A, Nardella R, Gabbanelli V, Scarcella M, Romanelli M, Romagnoli L et al. The ability of PiCCO versus LiDCOvariables to detect changes in cardiac index: a prospective clinical study. Minerva Anestesiol 2008;74:367-74.
-
(2008)
Minerva Anestesiol
, vol.74
, pp. 367-374
-
-
Donati, A.1
Nardella, R.2
Gabbanelli, V.3
Scarcella, M.4
Romanelli, M.5
Romagnoli, L.6
-
7
-
-
0036799972
-
PulseCO: A less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery
-
Hamilton TT, Huber LM, Jessen ME. PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery. Ann Thorac Surg 2002;74:S1408-12.
-
(2002)
Ann Thorac Surg
, vol.74
-
-
Hamilton, T.T.1
Huber, L.M.2
Jessen, M.E.3
-
8
-
-
26844502897
-
Edwards FloTrac sensor and Vigileo monitor: Easy, accurate, reliable cardiac output assessment using the arterial pulse wave
-
Manecke GR. Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave. ExpertRevMed Devices 2005;2:523-7.
-
(2005)
ExpertRevMed Devices
, vol.2
, pp. 523-527
-
-
Manecke, G.R.1
-
9
-
-
44049083321
-
Arterial pressure-based cardiac output assessment
-
Maus TM, Lee DE. Arterial pressure-based cardiac output assessment. J Cardiothorac Vasc Anesth 2008;22:468-73.
-
(2008)
J Cardiothorac Vasc Anesth
, vol.22
, pp. 468-473
-
-
Maus, T.M.1
Lee, D.E.2
-
10
-
-
77950020487
-
Cardiac Index validation using the Pressure Recording Analytic Method in unstable patients
-
[Epub ahead of print]
-
Zangrillo A, Maj G, Monaco F, Scandroglio AM, Nuzzi M, Plumari V et al. Cardiac Index validation using the Pressure Recording Analytic Method in unstable patients. J Cardiothorac Vasc Anesth [Epub ahead of print].
-
J Cardiothorac Vasc Anesth
-
-
Zangrillo, A.1
Maj, G.2
Monaco, F.3
Scandroglio, A.M.4
Nuzzi, M.5
Plumari, V.6
-
11
-
-
0033003166
-
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
-
Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J ClinMonitComput 1999;15:85-91.
-
(1999)
J ClinMonitComput
, vol.15
, pp. 85-91
-
-
Critchley, L.A.1
Critchley, J.A.2
-
12
-
-
68849121782
-
Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies with specific reference to the measurement of cardiac output
-
Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies with specific reference to the measurement of cardiac output. Crit Care 2009;13:201.
-
(2009)
Crit Care
, vol.13
, pp. 201
-
-
Cecconi, M.1
Rhodes, A.2
Poloniecki, J.3
della Rocca, G.4
Grounds, R.M.5
-
13
-
-
60449102439
-
Lithium dilution cardiac output measurement in the critically ill patient: Determination of precision of the technique
-
Cecconi M, Dawson D, Grounds RM, Rhodes A. Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique. Intensive Care Med 2009;35:498-504.
-
(2009)
Intensive Care Med
, vol.35
, pp. 498-504
-
-
Cecconi, M.1
Dawson, D.2
Grounds, R.M.3
Rhodes, A.4
-
14
-
-
34548254794
-
Measurement of cardiac output: A comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis
-
Sakka SG, Kozieras J, Thuemer O, van Hout N. Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth 2007;99:337-42.
-
(2007)
Br J Anaesth
, vol.99
, pp. 337-342
-
-
Sakka, S.G.1
Kozieras, J.2
Thuemer, O.3
van Hout, N.4
-
15
-
-
36549031653
-
Validation of a continuous, arterial pressure-based cardiac output measurement: A multicenter, prospective clinical trial
-
(London, England)
-
Mcgee W, Horswell J, Calderon J. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial. Critical Care (London, England) 2007;11:R105.
-
(2007)
Critical Care
, vol.11
-
-
McGee, W.1
Horswell, J.2
Calderon, J.3
-
16
-
-
41949139754
-
Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients
-
Compton FD, Zukunft B, Hoffmann C, Zidek W, Schaefer JH. Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients. Br J Anaesth 2008;100:451-6.
-
(2008)
Br J Anaesth
, vol.100
, pp. 451-456
-
-
Compton, F.D.1
Zukunft, B.2
Hoffmann, C.3
Zidek, W.4
Schaefer, J.H.5
-
17
-
-
36448936056
-
Evaluation of an improved algorithm for arterial pressurebased cardiac output assessment without external calibration
-
Prasser C, Trabold B, Schwab A, Keyl C, Ziegler S, Wiesenack C. Evaluation of an improved algorithm for arterial pressurebased cardiac output assessment without external calibration. Intensive Care Med 2007;33:2223-5.
-
(2007)
Intensive Care Med
, vol.33
, pp. 2223-2225
-
-
Prasser, C.1
Trabold, B.2
Schwab, A.3
Keyl, C.4
Ziegler, S.5
Wiesenack, C.6
-
18
-
-
33847753396
-
Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
-
Mayer J, Boldt J, Schöllhorn T, Röhm KD, Mengistu AM, Suttner S. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007;98: 176-82.
-
(2007)
Br J Anaesth
, vol.98
, pp. 176-182
-
-
Mayer, J.1
Boldt, J.2
Schöllhorn, T.3
Röhm, K.D.4
Mengistu, A.M.5
Suttner, S.6
-
19
-
-
33646711601
-
Arterial Pulse Power Analysis: The LiDCOplus System
-
In: Pinsky MR, editor, Berlin: Springer Verlag
-
Rhodes A. Arterial Pulse Power Analysis: The LiDCOplus System. In: Pinsky MR, editor. Functional Hemodynamic Monitoring. Berlin: Springer Verlag; 2004. p. 183-92.
-
(2004)
Functional Hemodynamic Monitoring
, pp. 183-192
-
-
Rhodes, A.1
-
20
-
-
24944439222
-
Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement
-
Pittman J, Bar-Yosef S, SumPing J, Sherwood M, Mark J. Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med 2005;33:2015-21.
-
(2005)
Crit Care Med
, vol.33
, pp. 2015-2021
-
-
Pittman, J.1
Bar-Yosef, S.2
Sumping, J.3
Sherwood, M.4
Mark, J.5
-
21
-
-
34548266524
-
Clinical evaluation of the FloTrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
-
Button D, Weibel L, Reuthebuch O, Genoni M. Clinical evaluation of the FloTrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007;99: 329-36.
-
(2007)
Br J Anaesth
, vol.99
, pp. 329-336
-
-
Button, D.1
Weibel, L.2
Reuthebuch, O.3
Genoni, M.4
|