메뉴 건너뛰기




Volumn 28, Issue 4, 2000, Pages 427-430

Clinical evaluation of the Non-invasive Cardiac Output (NICO) monitor in the intensive care unit

Author keywords

Monitoring: cardiac output, non invasive

Indexed keywords

ARTICLE; CARBON DIOXIDE TENSION; CLINICAL ARTICLE; COMPARATIVE STUDY; CORRELATION FUNCTION; EVALUATION; HEART OUTPUT; HEART SURGERY; HUMAN; INTENSIVE CARE; MATHEMATICAL PARAMETERS; MEASUREMENT; PATIENT MONITORING; POSTOPERATIVE PERIOD; REBREATHING; STATISTICAL ANALYSIS; THERMODILUTION;

EID: 0033864048     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x0002800412     Document Type: Article
Times cited : (65)

References (7)
  • 2
    • 0001679042 scopus 로고    scopus 로고
    • Clinical evaluation of a new non-invasive method of cardiac output measurement - Preliminary results in CABG patients
    • Guzzi L, Jaffe MB, Orr JA. Clinical evaluation of a new non-invasive method of cardiac output measurement - preliminary results in CABG patients. Anesthesiology 1998; 89:A543.
    • (1998) Anesthesiology , vol.89
    • Guzzi, L.1    Jaffe, M.B.2    Orr, J.A.3
  • 4
    • 0001337556 scopus 로고    scopus 로고
    • 2 rebreathing. A comparison with continuous and bolus thermodilution cardiac output
    • 2 rebreathing. A comparison with continuous and bolus thermodilution cardiac output. Anesthesiology 1998; 89:A544.
    • (1998) Anesthesiology , vol.89
    • Jopling, M.W.1
  • 5
    • 0000923780 scopus 로고    scopus 로고
    • Evaluation of partial rebreathing cardiac output measurement during surgery
    • Kuck K, Haryadi DG, Orr JA, Bailey PL. Evaluation of partial rebreathing cardiac output measurement during surgery. Anesthesiology 1998; 89:A542.
    • (1998) Anesthesiology , vol.89
    • Kuck, K.1    Haryadi, D.G.2    Orr, J.A.3    Bailey, P.L.4
  • 6
    • 0031001405 scopus 로고    scopus 로고
    • Partial carbon dioxide rebreathing: A reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow
    • Gama de Abreu M, Quintel M, Ragaller M, Albrecht M. Partial carbon dioxide rebreathing: A reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow. Crit Care Med 1997; 25:675-683.
    • (1997) Crit Care Med , vol.25 , pp. 675-683
    • Gama De Abreu, M.1    Quintel, M.2    Ragaller, M.3    Albrecht, M.4
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.