메뉴 건너뛰기




Volumn 15, Issue 3, 2014, Pages 281-291

Microneedle-based drug delivery systems for transdermal route

Author keywords

Drug delivery; Microneedles; Safety; Skin penetration enhancement; Stratum corneum; Transdermal delivery

Indexed keywords

ACICLOVIR; AMINOLEVULINIC ACID; BACTERIAL ANTIGEN; CALCEIN; CARBOXYFLUORESCEIN; CHIMERIVAX; DESMOPRESSIN; DIPHTHERIA VACCINE; DOCETAXEL; DRUG ADJUVANT; INFLUENZA VACCINE; INSULIN; MANNITOL; METAL; NALTREXONE; NICARDIPINE; PLASMID DNA; STAINLESS STEEL; UNCLASSIFIED DRUG;

EID: 84896722028     PISSN: 13894501     EISSN: 18735592     Source Type: Journal    
DOI: 10.2174/13894501113146660232     Document Type: Review
Times cited : (51)

References (96)
  • 3
    • 0031852494 scopus 로고    scopus 로고
    • Microfabricated microneedles: A novel approach to transdermal drug delivery
    • Henry S, McAllister DV, Allen MG, Prausnitz MR. Microfabricated microneedles: a novel approach to transdermal drug delivery. J Pharm Sci 1998; 87(8): 922-5.
    • (1998) J Pharm Sci , vol.87 , Issue.8 , pp. 922-925
    • Henry, S.1    McAllister, D.V.2    Allen, M.G.3    Prausnitz, M.R.4
  • 4
    • 0035142406 scopus 로고    scopus 로고
    • Lack of Pain Associated with Microfabricated Microneedles
    • Kaushik S, Hord AH, Denson DD, et al. Lack of Pain Associated with Microfabricated Microneedles. Anesth Analg 2001; 92: 502-4.
    • (2001) Anesth Analg , vol.92 , pp. 502-504
    • Kaushik, S.1    Hord, A.H.2    Denson, D.D.3
  • 5
    • 1542358759 scopus 로고    scopus 로고
    • Microneedles for transdermal drug delivery
    • Prausnitz MR. Microneedles for transdermal drug delivery. Adv Drug Deliv Rev 2004; 56: 581-7.
    • (2004) Adv Drug Deliv Rev , vol.56 , pp. 581-587
    • Prausnitz, M.R.1
  • 6
    • 0037462995 scopus 로고    scopus 로고
    • Microfabricated drug delivery systems: From particles to pores
    • Tao SL, Desai TA. Microfabricated drug delivery systems: from particles to pores. Adv Drug Deliv Rev 2003; 55: 315-28.
    • (2003) Adv Drug Deliv Rev , vol.55 , pp. 315-328
    • Tao, S.L.1    Desai, T.A.2
  • 7
    • 0013229597 scopus 로고    scopus 로고
    • Three-dimensional hollow microneedles and microtube arrays
    • Transducers 99, Actuators, 10th, Sendai, Tokyo: IEEE
    • McAllister DV, Cros F, Davis SP, et al. Three-dimensional hollow microneedles and microtube arrays. Transducers 99, Int. Conf. Solid-State Sens. Actuators, 10th, Sendai, pp. 1098-101. Tokyo: IEEE, 1999.
    • (1999) Int. Conf. Solid-State Sens. , pp. 1098-1101
    • McAllister, D.V.1    Cros, F.2    Davis, S.P.3
  • 8
    • 0032733868 scopus 로고    scopus 로고
    • Solid and hollow microneedles for transdermal drug delivery
    • 26th, Boston, Deerfield, IL:Control Release Soc
    • McAllister DV, Kaushik S, Patel PN, et al. Solid and hollow microneedles for transdermal drug delivery. Proc Int Symp Control Release Bioact Mater 1999; 26th, Boston, pp. 192-93. Deerfield, IL:Control Release Soc.
    • (1999) Proc Int Symp Control Release Bioact Mater , pp. 192-193
    • McAllister, D.V.1    Kaushik, S.2    Patel, P.N.3
  • 9
    • 0035659567 scopus 로고    scopus 로고
    • Transermal delivery of antisense oligonucleotides with microprojection patch (Macroflux) technology
    • Lin WQ, Cormier M, Samiee A, et al. Transermal delivery of antisense oligonucleotides with microprojection patch (Macroflux) technology. Pharm Res 2001; 18: 1789-93.
    • (2001) Pharm Res , vol.18 , pp. 1789-1793
    • Lin, W.Q.1    Cormier, M.2    Samiee, A.3
  • 10
    • 3042556333 scopus 로고    scopus 로고
    • Transdermal delivery of desmopressin using a coated microneedle array patch system J
    • Cormier M, Johnson B, Ameri M, et al. Transdermal delivery of desmopressin using a coated microneedle array patch system J. Control Rel. 2004; 97: 503-11
    • (2004) Control Rel. , vol.97 , pp. 503-511
    • Cormier, M.1    Johnson, B.2    Ameri, M.3
  • 11
    • 33846492454 scopus 로고    scopus 로고
    • Coated microneedles for transdermal delivery
    • Gill HS, Prausnitz MR. Coated microneedles for transdermal delivery. J Control Release 2007; 117: 227-37.
    • (2007) J Control Release , vol.117 , pp. 227-237
    • Gill, H.S.1    Prausnitz, M.R.2
  • 12
    • 47349128121 scopus 로고    scopus 로고
    • Microneedlemediated intradermal delivery of 5-aminolevulinic acid: Potential for enhanced topical photodynamic therapy
    • Donnelly RF, Morrowa DIJ, McCarron PA, et al. Microneedlemediated intradermal delivery of 5-aminolevulinic acid: Potential for enhanced topical photodynamic therapy. J Control Release 2008; 129: 154-62.
    • (2008) J Control Release , vol.129 , pp. 154-162
    • Donnelly, R.F.1    Morrowa, D.I.J.2    McCarron, P.A.3
  • 13
    • 67649858840 scopus 로고    scopus 로고
    • Minimally invasive insulin delivery in subjects with type 1 diabetes using hollow microneedles
    • Gupta J, Felner EI, Prausnitz MR. Minimally invasive insulin delivery in subjects with type 1 diabetes using hollow microneedles. Diabetes Technol Ther 2009; 11(6): 329-37.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.6 , pp. 329-337
    • Gupta, J.1    Felner, E.I.2    Prausnitz, M.R.3
  • 14
    • 78649772289 scopus 로고    scopus 로고
    • Advances in transcutaneous vaccine delivery: Do all ways lead to Rome?
    • Bal SM, Ding Z, van Riet E, Jiskoot W, Bouwstra JA. Advances in transcutaneous vaccine delivery: Do all ways lead to Rome? J Control Rel 2010; 148 (3): 266-82.
    • (2010) J Control Rel , vol.148 , Issue.3 , pp. 266-282
    • Bal, S.M.1    Ding, Z.2    van Riet, E.3    Jiskoot, W.4    Bouwstra, J.A.5
  • 15
    • 0344270926 scopus 로고    scopus 로고
    • Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies
    • McAllister DV, Wang PM., Davis SP, et al. Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies. Proc Natl Acad Sci USA 2003; 100 (24): 13755-60.
    • (2003) Proc Natl Acad Sci USA , vol.100 , Issue.24 , pp. 13755-13760
    • McAllister, D.V.1    Wang, P.M.2    Davis, S.P.3
  • 16
    • 57849157314 scopus 로고    scopus 로고
    • Microneedle mediated delivery of nanoparticles into human skin
    • Coulman SA, Anstey A, Gateley C, et al. Microneedle mediated delivery of nanoparticles into human skin. Int J Pharm 2009; 366: 190-200.
    • (2009) Int J Pharm , vol.366 , pp. 190-200
    • Coulman, S.A.1    Anstey, A.2    Gateley, C.3
  • 17
    • 46549083407 scopus 로고    scopus 로고
    • Enhancement of skin permeation of docetaxel: A novel approach combining microneedle and elastic liposomes
    • Qiu Y, Gao Y, Hu K, Li F. Enhancement of skin permeation of docetaxel: A novel approach combining microneedle and elastic liposomes. J Control Rel 2008; 129: 144-50.
    • (2008) J Control Rel , vol.129 , pp. 144-150
    • Qiu, Y.1    Gao, Y.2    Hu, K.3    Li, F.4
  • 18
    • 59349105168 scopus 로고    scopus 로고
    • Skin penetration enhancement by a microneedle device (Dermaroller®) in vitro: Dependency on needle size and applied formulation
    • Badran MM, Kuntsche J, Fahr A. Skin penetration enhancement by a microneedle device (Dermaroller®) in vitro: Dependency on needle size and applied formulation Eur J Pharm Sci 2009; 36: 511-23.
    • (2009) Eur J Pharm Sci , vol.36 , pp. 511-523
    • Badran, M.M.1    Kuntsche, J.2    Fahr, A.3
  • 19
    • 44649083690 scopus 로고    scopus 로고
    • Flux Across Microneedletreated Skin is Increased by Increasing Charge of Naltrexone and Naltrexol In Vitro
    • Banks SL, Pinninti RR, Gill HS, et al. Flux Across Microneedletreated Skin is Increased by Increasing Charge of Naltrexone and Naltrexol In Vitro Pharm Res 2008; 25(7): 1677-85.
    • (2008) Pharm Res , vol.25 , Issue.7 , pp. 1677-1685
    • Banks, S.L.1    Pinninti, R.R.2    Gill, H.S.3
  • 20
    • 3042809905 scopus 로고    scopus 로고
    • Transdermal Delivery of Insulin Using Microneedles in Vivo
    • Martanto W, Davis SP, Holiday NR, et al. Transdermal Delivery of Insulin Using Microneedles in Vivo. Pharm Res 2004; 21(6): 947-52.
    • (2004) Pharm Res , vol.21 , Issue.6 , pp. 947-952
    • Martanto, W.1    Davis, S.P.2    Holiday, N.R.3
  • 21
    • 42749084964 scopus 로고    scopus 로고
    • Improved piercing of microneedle arrays in dermatomed human skin by an impact insertion method
    • Verbaan FJ, Bal SM, van den Berg DJ, et al. Improved piercing of microneedle arrays in dermatomed human skin by an impact insertion method J Control Rel 2008; 128: 80-8.
    • (2008) J Control Rel , vol.128 , pp. 80-88
    • Verbaan, F.J.1    Bal, S.M.2    van den Berg, D.J.3
  • 22
    • 67349252458 scopus 로고    scopus 로고
    • Microneedle arrays for the transcutaneous immunization of diphtheria and influenza in BALB/c mice
    • Ding Z, Verbaan FJ, Bivas-Benita M, et al. Microneedle arrays for the transcutaneous immunization of diphtheria and influenza in BALB/c mice. J Control Rel 2009; 136: 71-8.
    • (2009) J Control Rel , vol.136 , pp. 71-78
    • Ding, Z.1    Verbaan, F.J.2    Bivas-Benita, M.3
  • 23
    • 77951434882 scopus 로고    scopus 로고
    • Microneedle-bases drug delivery systems: Microfabrication, drug delivery and safety
    • Donnelly RF, Singh TRR, Woolfson AD. Microneedle-bases drug delivery systems: microfabrication, drug delivery and safety. Drug Deliv 2010; 17(4): 187-207.
    • (2010) Drug Deliv , vol.17 , Issue.4 , pp. 187-207
    • Donnelly, R.F.1    Singh, T.R.R.2    Woolfson, A.D.3
  • 24
    • 55649101168 scopus 로고    scopus 로고
    • Micro-scale devices for transdermal drug delivery
    • Arora A, Prausnitz MR, Mitragotri S. Micro-scale devices for transdermal drug delivery. Int J Pharm 2008; 364: 227-36.
    • (2008) Int J Pharm , vol.364 , pp. 227-236
    • Arora, A.1    Prausnitz, M.R.2    Mitragotri, S.3
  • 25
    • 18144410179 scopus 로고    scopus 로고
    • Biodegradable polymer microneedles: Fabrication, mechanics and tranderaml drug delivery
    • Park JH, Allen MG, Prausnitz MR. Biodegradable polymer microneedles: fabrication, mechanics and tranderaml drug delivery. J Control Rel 2005; 104: 51-66.
    • (2005) J Control Rel , vol.104 , pp. 51-66
    • Park, J.H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 26
    • 77952744825 scopus 로고    scopus 로고
    • Transdermal delivery of insulin using microneedle rollers in vivo Int
    • Zhou CP, Liu YL, Wang HL, Zhang PX, Zhang JL. Transdermal delivery of insulin using microneedle rollers in vivo Int J Pharm 2010; 392: 127-33.
    • (2010) J Pharm , vol.392 , pp. 127-133
    • Zhou, C.P.1    Liu, Y.L.2    Wang, H.L.3    Zhang, P.X.4    Zhang, J.L.5
  • 27
    • 39149100652 scopus 로고    scopus 로고
    • Gene delivery to the epidermal cells of human skin explants using microfabricated microneedles and hydrogel formulations
    • Pearton M, Allender C, Brain K, et al. Gene delivery to the epidermal cells of human skin explants using microfabricated microneedles and hydrogel formulations. Pharm Res 2008; 25(2): 407-16.
    • (2008) Pharm Res , vol.25 , Issue.2 , pp. 407-416
    • Pearton, M.1    Allender, C.2    Brain, K.3
  • 28
    • 48149083798 scopus 로고    scopus 로고
    • Influence of the delivery systems using a microneedle array on the permeation of a hydrophilic molecule, calcein
    • Oh JH, Park HH, Do KY, et al. Influence of the delivery systems using a microneedle array on the permeation of a hydrophilic molecule, calcein. Eur J Pharm Biopharm 2008; 69: 1040-5.
    • (2008) Eur J Pharm Biopharm , vol.69 , pp. 1040-1045
    • Oh, J.H.1    Park, H.H.2    Do, K.Y.3
  • 29
    • 41149125953 scopus 로고    scopus 로고
    • Microneedles permit transdermal delivery of a skin-impermeant medication to humans
    • Wermeling DP, Banks SL, Hudson DA, et al. Microneedles permit transdermal delivery of a skin-impermeant medication to humans. Proc Natl Acad Sci USA 2008; 105(12): 2058-63.
    • (2008) Proc Natl Acad Sci USA , vol.105 , Issue.12 , pp. 2058-2063
    • Wermeling, D.P.1    Banks, S.L.2    Hudson, D.A.3
  • 30
    • 77952886320 scopus 로고    scopus 로고
    • Evaluation needle length and density of microneedle arrays in the pretreatment of skin for transdermal drug delivery
    • Yan G, Warner KS, Zhang J, Sharma S, Gale BK. Evaluation needle length and density of microneedle arrays in the pretreatment of skin for transdermal drug delivery Int J Pharm 2010; 391: 7-12.
    • (2010) Int J Pharm , vol.391 , pp. 7-12
    • Yan, G.1    Warner, K.S.2    Zhang, J.3    Sharma, S.4    Gale, B.K.5
  • 31
    • 32544446281 scopus 로고    scopus 로고
    • Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system
    • Widera G, Johnson J, Kim L, et al. Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system. Vaccine 2006; 24: 1653-64.
    • (2006) Vaccine , vol.24 , pp. 1653-1664
    • Widera, G.1    Johnson, J.2    Kim, L.3
  • 32
    • 48749105332 scopus 로고    scopus 로고
    • Microneedle-based drug delivery: Studies on delivery parameters and biocompatibility
    • Wu Y, Qiu Y, Zhang S, Qin G, Gao Y. Microneedle-based drug delivery: studies on delivery parameters and biocompatibility. Biomed Microdevices 2008; 10: 601-10.
    • (2008) Biomed Microdevices , vol.10 , pp. 601-610
    • Wu, Y.1    Qiu, Y.2    Zhang, S.3    Qin, G.4    Gao, Y.5
  • 33
    • 50449085359 scopus 로고    scopus 로고
    • In vivo assessment of safety of microneedle arrays in human skin
    • Bal, SM, Caussin J, Pavel S, Bouwstra JA. In vivo assessment of safety of microneedle arrays in human skin. Eur J Pharm Sci 2008; 35: 193-202.
    • (2008) Eur J Pharm Sci , vol.35 , pp. 193-202
    • Bal, S.M.1    Caussin, J.2    Pavel, S.3    Bouwstra, J.A.4
  • 34
    • 70350215864 scopus 로고    scopus 로고
    • Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro
    • Donnelly RF, Singh TRR, Tunney MM, et al. Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro. Pharm Res 2009; 26(11): 2513-22.
    • (2009) Pharm Res , vol.26 , Issue.11 , pp. 2513-2522
    • Donnelly, R.F.1    Singh, T.R.R.2    Tunney, M.M.3
  • 35
    • 2942716734 scopus 로고    scopus 로고
    • Insertion of microneedles into skin: Measurement ans prediction of insertion force and needle fracture force
    • Davis SP, Landis BJ, Adams ZH, Allen MG, Prausnitz MR. Insertion of microneedles into skin: measurement ans prediction of insertion force and needle fracture force. J Biomech 2004; 37: 1155-63.
    • (2004) J Biomech , vol.37 , pp. 1155-1163
    • Davis, S.P.1    Landis, B.J.2    Adams, Z.H.3    Allen, M.G.4    Prausnitz, M.R.5
  • 36
    • 79951955119 scopus 로고    scopus 로고
    • Separable Arrowhead Microneedles
    • Chu LY, Prausnitz MR. Separable Arrowhead Microneedles J Control Rel 2011; 149(3): 242-9
    • (2011) J Control Rel , vol.149 , Issue.3 , pp. 242-249
    • Chu, L.Y.1    Prausnitz, M.R.2
  • 37
    • 67349089494 scopus 로고    scopus 로고
    • Immune Modulation by Adjuvants Combined with Diphtheria Toxoid Administered Topically in BALB/c Mice After Microneedle
    • Ding Z, Van Riet E, Romeijn S, et al. Immune Modulation by Adjuvants Combined with Diphtheria Toxoid Administered Topically in BALB/c Mice After Microneedle Array Pretreatment Pharm Res 2009; 26(7): 1635-42.
    • (2009) Array Pretreatment Pharm Res , vol.26 , Issue.7 , pp. 1635-1642
    • Ding, Z.1    Van Riet, E.2    Romeijn, S.3
  • 38
    • 66049119152 scopus 로고    scopus 로고
    • Immunization by vaccine-coated microneedle arrays protects against lethal influenza virus challenge
    • Zhu Q, Zarnitsyn VG, Ye L, et al. Immunization by vaccine-coated microneedle arrays protects against lethal influenza virus challenge. Proc Natl Acad Sci USA 2009; 106(19): 7968-73.
    • (2009) Proc Natl Acad Sci USA , vol.106 , Issue.19 , pp. 7968-7973
    • Zhu, Q.1    Zarnitsyn, V.G.2    Ye, L.3
  • 39
    • 33645226351 scopus 로고    scopus 로고
    • Controlled transdermal delivery of model drug compounds by MEMS microneedle array
    • Xie Y, Xu B, Gao Y. Controlled transdermal delivery of model drug compounds by MEMS microneedle array. Nanomedicine: NBM 2005; 1: 184-90
    • (2005) Nanomedicine: NBM , vol.1 , pp. 184-190
    • Xie, Y.1    Xu, B.2    Gao, Y.3
  • 40
    • 76749169710 scopus 로고    scopus 로고
    • Formulation and coating of microneedles with inactivated influenza virus to improve vaccine stability and immunogenicity
    • Kim YC, Quan FS, Compans RW, Kang SM, Prausnitz MR. Formulation and coating of microneedles with inactivated influenza virus to improve vaccine stability and immunogenicity. J Control Rel 2010; 142: 187-95.
    • (2010) J Control Rel , vol.142 , pp. 187-195
    • Kim, Y.C.1    Quan, F.S.2    Compans, R.W.3    Kang, S.M.4    Prausnitz, M.R.5
  • 41
    • 62849117105 scopus 로고    scopus 로고
    • Transdermal Influenza Immunization with Vaccine-Coated Microneedle Arrays
    • Koutsonanos DG, Martin MP, Zarnitsyn VG, et al. Transdermal Influenza Immunization with Vaccine-Coated Microneedle Arrays. PLoS ONE 2009; 4(3): e4773.
    • (2009) PLoS ONE , vol.4 , Issue.3
    • Koutsonanos, D.G.1    Martin, M.P.2    Zarnitsyn, V.G.3
  • 43
  • 44
    • 4344666269 scopus 로고    scopus 로고
    • Microneedle array for transdermal biological fluid extraction and in situ analysis
    • Mukerjee EV, Collins SD, Isseroff RR, Smith RL Microneedle array for transdermal biological fluid extraction and in situ analysis. Sens Actua A Physical 2004; 114: 267-75.
    • (2004) Sens Actua A Physical , vol.114 , pp. 267-275
    • Mukerjee, E.V.1    Collins, S.D.2    Isseroff, R.R.3    Smith, R.L.4
  • 45
    • 70350702982 scopus 로고    scopus 로고
    • Penetrating the market with innovative transdermal technology
    • July/august. Available online at, accessed 13 May 2011
    • Dubin C. Penetrating the market with innovative transdermal technology. Drug Delivery Technology 2009; July/august, 9 (7): 44-47. Available online at http://www.drugdeliverytech-online.com/drug delivery/20090708/?pg=46#pg46, accessed 13 May 2011.
    • (2009) Drug Delivery Technology , vol.9 , Issue.7 , pp. 44-47
    • Dubin, C.1
  • 46
    • 84896701140 scopus 로고    scopus 로고
    • Available online at: accessed 05 June 2013
    • Nanopass Technology. Available online at: http://www.nano pass.com/ accessed 05 June 2013.
    • Nanopass Technology.
  • 47
    • 27844509988 scopus 로고    scopus 로고
    • Microfabricated drug delivery devices
    • Hilt JZ, Peppas NA. Microfabricated drug delivery devices. Int. J. Pharm 2005; 306: 15-23.
    • (2005) Int. J. Pharm , vol.306 , pp. 15-23
    • Hilt, J.Z.1    Peppas, N.A.2
  • 48
    • 40349099997 scopus 로고    scopus 로고
    • Membrane-sealed hollow microneedles and related administration schemes for transdermal drug delivery
    • Roxhed N, Griss P, Stemme G. Membrane-sealed hollow microneedles and related administration schemes for transdermal drug delivery. Biomed Microdevices 2008; 10: 271-9.
    • (2008) Biomed Microdevices , vol.10 , pp. 271-279
    • Roxhed, N.1    Griss, P.2    Stemme, G.3
  • 49
    • 33646148967 scopus 로고    scopus 로고
    • Precise Microinjection into Skin Using Hollow Microneedles
    • Wang PM, Cornwell M, Hill J. and Prausnitz MR. Precise Microinjection into Skin Using Hollow Microneedles. J Invest Dermatol 2006; 126: 1080-87.
    • (2006) J Invest Dermatol , vol.126 , pp. 1080-1087
    • Wang, P.M.1    Cornwell, M.2    Hill, J.3    Prausnitz, M.R.4
  • 50
    • 67649096926 scopus 로고    scopus 로고
    • Microporation applications for enhancing drug delivery
    • Banga AK. Microporation applications for enhancing drug delivery. Expert Opin Drug Deliv 2009; 6: 343-54.
    • (2009) Expert Opin Drug Deliv , vol.6 , pp. 343-354
    • Banga, A.K.1
  • 52
    • 0038547999 scopus 로고    scopus 로고
    • Characterization of surface micromachined metallic microneedles
    • Chandrasekaran S, Frazier AB. Characterization of surface micromachined metallic microneedles JMEMS 2003; 12: 289-95.
    • (2003) JMEMS , vol.12 , pp. 289-295
    • Chandrasekaran, S.1    Frazier, A.B.2
  • 55
    • 17444403584 scopus 로고    scopus 로고
    • Clinical microneedle injection of methyl nicotinate: Stratum corneum penetration Skin Res
    • Sivamani RK, Stoeber B, Wu GC., et al. Clinical microneedle injection of methyl nicotinate: stratum corneum penetration Skin Res. Technol 2005; 11 (2): 152-6.
    • (2005) Technol , vol.11 , Issue.2 , pp. 152-156
    • Sivamani, R.K.1    Stoeber, B.2    Wu, G.C.3
  • 56
    • 33646244630 scopus 로고    scopus 로고
    • Cutaneous delivery of a live, attenuated chimeric flavivirus vaccine against Japanese encephalitis (ChimeriVax)-JE) in non-human primates
    • Dean CH, Alarcon JB, Waterston et al. Cutaneous delivery of a live, attenuated chimeric flavivirus vaccine against Japanese encephalitis (ChimeriVax)-JE) in non-human primates. Hum Vaccines 2005; 1: 106-11.
    • (2005) Hum Vaccines , vol.1 , pp. 106-111
    • Dean, C.H.1    Alarcon, J.B.2    Waterston3
  • 57
    • 50949102312 scopus 로고    scopus 로고
    • Intradermal influenza vaccine administered using a new microinjection system produces superior immunogenicity in elderly adults: A randomized controlled trial
    • Holland D, Booy R, De Looze F, et al. Intradermal influenza vaccine administered using a new microinjection system produces superior immunogenicity in elderly adults: A randomized controlled trial. J. Infect Dis 2008; 198: 650-8.
    • (2008) J. Infect Dis , vol.198 , pp. 650-658
    • Holland, D.1    Booy, R.2    De Looze, F.3
  • 58
    • 33846593511 scopus 로고    scopus 로고
    • Smallpox DNA vaccine delivered by novel skin electroporation device protects mice against intranasal poxvirus challenge
    • Hooper JW, Golden JW, Ferro AM, King AD. Smallpox DNA vaccine delivered by novel skin electroporation device protects mice against intranasal poxvirus challenge. Vaccine 2007; 25: 1814-23.
    • (2007) Vaccine , vol.25 , pp. 1814-1823
    • Hooper, J.W.1    Golden, J.W.2    Ferro, A.M.3    King, A.D.4
  • 59
    • 78651288385 scopus 로고    scopus 로고
    • Multiphoton microscopy of transdermal quantum dot delivery using twophoton polymerization-fabricated polymer microneedles
    • Gittard SD, Miller PR, Boehm RD, et al. Multiphoton microscopy of transdermal quantum dot delivery using twophoton polymerization-fabricated polymer microneedles. Faraday Discus 2011; 149: 171-85.
    • (2011) Faraday Discus , vol.149 , pp. 171-185
    • Gittard, S.D.1    Miller, P.R.2    Boehm, R.D.3
  • 60
    • 33646882359 scopus 로고    scopus 로고
    • Polymer microneedles for controlled-release drug delivery
    • Park JH, Allen MG, Prausnitz MR. Polymer microneedles for controlled-release drug delivery Pharm Res 2006; 23: 1008-19.
    • (2006) Pharm Res , vol.23 , pp. 1008-1019
    • Park, J.H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 61
    • 34548174029 scopus 로고    scopus 로고
    • Laser fabrication of high aspect ratio thin holes on biodegradable polymer and its application to a microneedle
    • Aoyagi S, Hayato I, Yuich I, Mitsuo F, Ogawa H. Laser fabrication of high aspect ratio thin holes on biodegradable polymer and its application to a microneedle Sens Actuators A Physical 2007; 139: 293-302.
    • (2007) Sens Actuators A Physical , vol.139 , pp. 293-302
    • Aoyagi, S.1    Hayato, I.2    Yuich, I.3    Mitsuo, F.4    Ogawa, H.5
  • 62
    • 40049112272 scopus 로고    scopus 로고
    • Dissolving microneedles for transdermal drug delivery
    • Jeong WL, Park JH, Prausnitz MR. Dissolving microneedles for transdermal drug delivery. Biomaterials 2008; 29: 2113-24.
    • (2008) Biomaterials , vol.29 , pp. 2113-2124
    • Jeong, W.L.1    Park, J.H.2    Prausnitz, M.R.3
  • 63
    • 33344467371 scopus 로고    scopus 로고
    • Sharp beveled tip hollow microneedle arrays fabricated by LIGA and 3D soft lithography with polyvinyl alcohol
    • Perennes F, Marmiroli B, Matteucci M, et al. Sharp beveled tip hollow microneedle arrays fabricated by LIGA and 3D soft lithography with polyvinyl alcohol J Micromech Microeng 2006; 16: 473-9.
    • (2006) J Micromech Microeng , vol.16 , pp. 473-479
    • Perennes, F.1    Marmiroli, B.2    Matteucci, M.3
  • 64
    • 33847264564 scopus 로고    scopus 로고
    • Polymer investment molding: Method for fabricating hollow, microscale parts
    • Lippmann JM, Geiger EJ, Pisano AP. Polymer investment molding: Method for fabricating hollow, microscale parts. Sens Actuators: A Physical 2007; 134: 2-10.
    • (2007) Sens Actuators: A Physical , vol.134 , pp. 2-10
    • Lippmann, J.M.1    Geiger, E.J.2    Pisano, A.P.3
  • 65
    • 60849112814 scopus 로고    scopus 로고
    • Improvement in antigendelivery using fabrication of a grooves-embedded microneedle array
    • Han M, Kim DK, Seong HK, et al. Improvement in antigendelivery using fabrication of a grooves-embedded microneedle array. Sens Actuators B 2009; 137: 274-80.
    • (2009) Sens Actuators B , vol.137 , pp. 274-280
    • Han, M.1    Kim, D.K.2    Seong, H.K.3
  • 66
    • 33847301400 scopus 로고    scopus 로고
    • Polymeric microneedle fabrication using a microinjection molding technique
    • Sammoura F, Kang JJ, Heo YM, Tae SJ, Liwei L. Polymeric microneedle fabrication using a microinjection molding technique. Microsyst Technol 2007; 13: 517-22.
    • (2007) Microsyst Technol , vol.13 , pp. 517-522
    • Sammoura, F.1    Kang, J.J.2    Heo, Y.M.3    Tae, S.J.4    Liwei, L.5
  • 67
    • 24144465860 scopus 로고    scopus 로고
    • J A novel fabrication method of a micro-needle array using inclined deep x-ray exposure
    • Moon SJ, Lee SS. J A novel fabrication method of a micro-needle array using inclined deep x-ray exposure Micromech Microeng 2005; 15: 903-11.
    • (2005) Micromech Microeng , vol.15 , pp. 903-911
    • Moon, S.J.1    Lee, S.S.2
  • 68
    • 34249710930 scopus 로고    scopus 로고
    • A novel fabrication process for out-of-plane microneedle sheets of biocompatible polymer
    • Han M, Hyun DH, Park HH, et al. A novel fabrication process for out-of-plane microneedle sheets of biocompatible polymer. J Micromech Microeng 2007; 17: 1184-91.
    • (2007) J Micromech Microeng , vol.17 , pp. 1184-1191
    • Han, M.1    Hyun, D.H.2    Park, H.H.3
  • 69
    • 33846699005 scopus 로고    scopus 로고
    • Two photon polymerization of polymer-ceramic hybrid materials for transdermal drug delivery
    • Ovsianikov A, Chichkov B, Mente P, et al. Two photon polymerization of polymer-ceramic hybrid materials for transdermal drug delivery. Int J Appl Ceramic Tech 2007; 4: 22-9.
    • (2007) Int J Appl Ceramic Tech , vol.4 , pp. 22-29
    • Ovsianikov, A.1    Chichkov, B.2    Mente, P.3
  • 70
    • 54949120972 scopus 로고    scopus 로고
    • Minimally invasive protein delivery with rapidly dissolving polymer microneedles
    • Sullivan SP, Murthy N, Prausnitz MR. Minimally invasive protein delivery with rapidly dissolving polymer microneedles. Adv Mater 2008; 20: 933-8.
    • (2008) Adv Mater , vol.20 , pp. 933-938
    • Sullivan, S.P.1    Murthy, N.2    Prausnitz, M.R.3
  • 71
    • 2942592481 scopus 로고    scopus 로고
    • Bioabsorbable implants: Review of clinical experience in orthopedic surgery
    • Ambrose CG, Clanto TO. Bioabsorbable implants: review of clinical experience in orthopedic surgery Ann Biomed Eng 2004; 32: 171-7.
    • (2004) Ann Biomed Eng , vol.32 , pp. 171-177
    • Ambrose, C.G.1    Clanto, T.O.2
  • 72
    • 3042822474 scopus 로고    scopus 로고
    • Microfabricated silicon microneedles for nonviral cutaneous gene delivery J
    • Chabri F, Bouris K, Jones T, et al. Microfabricated silicon microneedles for nonviral cutaneous gene delivery J. Br Dermatol 2004; 150: 869-77.
    • (2004) Br Dermatol , vol.150 , pp. 869-877
    • Chabri, F.1    Bouris, K.2    Jones, T.3
  • 74
    • 77957370415 scopus 로고    scopus 로고
    • Microneedle pretreatment of human skin improves 5-aminolevulininc acid (ALA)-and 5-aminolevulinic acid methyl ester (MAL)-induced PpIX production for topical photodynamic therapy without increase in pain or erythema
    • Mikolajewska P, Donnelly RF, Garland MJ, et al. Microneedle pretreatment of human skin improves 5-aminolevulininc acid (ALA)-and 5-aminolevulinic acid methyl ester (MAL)-induced PpIX production for topical photodynamic therapy without increase in pain or erythema. Pharm Res 2010; 27: 2213-20.
    • (2010) Pharm Res , vol.27 , pp. 2213-2220
    • Mikolajewska, P.1    Donnelly, R.F.2    Garland, M.J.3
  • 75
    • 24144480586 scopus 로고    scopus 로고
    • Sugar micro needles as transdermic drug delivery system
    • Miyano T, Tobinaga Y, Takahiro K, et al. Sugar micro needles as transdermic drug delivery system. Biomed Microdevices, 7,185-8, 2005.
    • (2005) Biomed Microdevices , vol.7 , pp. 185-188
    • Miyano, T.1    Tobinaga, Y.2    Takahiro, K.3
  • 76
    • 58949100880 scopus 로고    scopus 로고
    • In vitro transdermal delivery of therapeutics antibodies usingmaltose microneedles
    • Li G, Badkarb A, Nemab S, Kolli CS, Bangaa AK. In vitro transdermal delivery of therapeutics antibodies usingmaltose microneedles. Int J Pharm 2009; 368: 109-15.
    • (2009) Int J Pharm , vol.368 , pp. 109-115
    • Li, G.1    Badkarb, A.2    Nemab, S.3    Kolli, C.S.4    Bangaa, A.K.5
  • 77
    • 38049146196 scopus 로고    scopus 로고
    • Characterization of solid maltose microneedles and their use for transdermal delivery
    • Kolli CS, Banga AK. Characterization of solid maltose microneedles and their use for transdermal delivery. Pharm Res 2008; 25: 104-13.
    • (2008) Pharm Res , vol.25 , pp. 104-113
    • Kolli, C.S.1    Banga, A.K.2
  • 78
    • 33747748467 scopus 로고    scopus 로고
    • Feasibility of microneedles for percutaneous absorption of insulin
    • Ito Y, Hagiwara E, Saeki A, Sugioka N, Takada K. Feasibility of microneedles for percutaneous absorption of insulin. Eur J Pharm Sci 2006; 29: 82-88.
    • (2006) Eur J Pharm Sci , vol.29 , pp. 82-88
    • Ito, Y.1    Hagiwara, E.2    Saeki, A.3    Sugioka, N.4    Takada, K.5
  • 79
    • 37349124148 scopus 로고    scopus 로고
    • Evaluation of self-dissolving needles containing low molecular weight heparin (LMWH) in rats
    • Ito Y, Murakami A, Maeda T, Sugioka N, Takada K. Evaluation of self-dissolving needles containing low molecular weight heparin (LMWH) in rats. Int J Pharm 2008; 349: 124-9.
    • (2008) Int J Pharm , vol.349 , pp. 124-129
    • Ito, Y.1    Murakami, A.2    Maeda, T.3    Sugioka, N.4    Takada, K.5
  • 80
    • 40049112272 scopus 로고    scopus 로고
    • Dissolving microneedles for transdermal drug delivery
    • Lee JW, Park JH, Prausnitz MR. Dissolving microneedles for transdermal drug delivery. Biomaterials 2008; 29, 2113-24.
    • (2008) Biomaterials , vol.29 , pp. 2113-2124
    • Lee, J.W.1    Park, J.H.2    Prausnitz, M.R.3
  • 81
    • 85027919002 scopus 로고    scopus 로고
    • Two-layered dissolving microneedles for percutaneous delivery of peptide/protein drugs in rats
    • Fukushima K, Ise A, Morita H. Two-layered dissolving microneedles for percutaneous delivery of peptide/protein drugs in rats. Pharm Res 2011; 28: 7-21.
    • (2011) Pharm Res , vol.28 , pp. 7-21
    • Fukushima, K.1    Ise, A.2    Morita, H.3
  • 82
    • 38349175137 scopus 로고    scopus 로고
    • Synergistic effect of iontophoresis and soluble microneedles for transdermal delivery of methotrexate
    • Vemulapalli V, Yang Y, Friden PM, Banga AK. Synergistic effect of iontophoresis and soluble microneedles for transdermal delivery of methotrexate J Pharm Pharmacol 2008; 60: 27-33.
    • (2008) J Pharm Pharmacol , vol.60 , pp. 27-33
    • Vemulapalli, V.1    Yang, Y.2    Friden, P.M.3    Banga, A.K.4
  • 83
    • 53549130424 scopus 로고    scopus 로고
    • Protein and peptides: Strategies for delivery to and across the skin
    • Benson HAE, Namjoshi S. Protein and peptides: strategies for delivery to and across the skin. J Pharm Sci 2008; 97 (9): 3591-610.
    • (2008) J Pharm Sci , vol.97 , Issue.9 , pp. 3591-3610
    • Benson, H.A.E.1    Namjoshi, S.2
  • 84
    • 0036007129 scopus 로고    scopus 로고
    • Macroflux microprojection array patch technology: A new and efficient approach for intracutaneous immunization
    • Matriano JA, Cormier M, Johnson J, et al. Macroflux microprojection array patch technology: a new and efficient approach for intracutaneous immunization. Pharm Res 2002; 19: 63-70.
    • (2002) Pharm Res , vol.19 , pp. 63-70
    • Matriano, J.A.1    Cormier, M.2    Johnson, J.3
  • 85
    • 3042556333 scopus 로고    scopus 로고
    • Transdermal delivery of desmopressin using a coated microneedle array patch system
    • Cormier M, Johnson B, Ameri M, et al. Transdermal delivery of desmopressin using a coated microneedle array patch system J Control Rel 2004; 97: 503-11.
    • (2004) J Control Rel , vol.97 , pp. 503-511
    • Cormier, M.1    Johnson, B.2    Ameri, M.3
  • 86
    • 32544446281 scopus 로고    scopus 로고
    • Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system
    • Widera G, Johnson J, Kim L, et al. Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system Vaccine 2006; 24: 1653-64.
    • (2006) Vaccine , vol.24 , pp. 1653-1664
    • Widera, G.1    Johnson, J.2    Kim, L.3
  • 87
    • 0036105150 scopus 로고    scopus 로고
    • Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery
    • Mikszta JA, Alarcon JB, Brittingham JM, et al. Improved genetic immunization via micromechanical disruption of skin-barrier function and targeted epidermal delivery Nat Med 2002; 8: 415-9.
    • (2002) Nat Med , vol.8 , pp. 415-419
    • Mikszta, J.A.1    Alarcon, J.B.2    Brittingham, J.M.3
  • 89
    • 19944429357 scopus 로고    scopus 로고
    • Protective Immunization against Inhalational Anthrax: A Comparison of Minimally Invasive Delivery Platforms
    • Mikszta JA, Sullivan VJ, Dean C, et al. Protective Immunization against Inhalational Anthrax: A Comparison of Minimally Invasive Delivery Platforms J Infect Dis 2005; 191: 278-88.
    • (2005) J Infect Dis , vol.191 , pp. 278-288
    • Mikszta, J.A.1    Sullivan, V.J.2    Dean, C.3
  • 90
    • 34248344256 scopus 로고    scopus 로고
    • Preclinical Evaluation of Microneedle Technology for Intradermal Delivery of Influenza Vaccines
    • Alarcon JB, Hartley AW, Harvey NG, Mikszta JA. Preclinical Evaluation of Microneedle Technology for Intradermal Delivery of Influenza Vaccines. Clin. Vacc. Immunol 2007; 14: 375-81.
    • (2007) Clin. Vacc. Immunol , vol.14 , pp. 375-381
    • Alarcon, J.B.1    Hartley, A.W.2    Harvey, N.G.3    Mikszta, J.A.4
  • 92
    • 34548454589 scopus 로고    scopus 로고
    • The mechanical properties of the skin epidermis in relation to targeted gene and drug delivery
    • Kendall MAF, Chong YF, Alexander C. The mechanical properties of the skin epidermis in relation to targeted gene and drug delivery. Biomaterials 2007; 28: 4968-77.
    • (2007) Biomaterials , vol.28 , pp. 4968-4977
    • Kendall, M.A.F.1    Chong, Y.F.2    Alexander, C.3
  • 93
    • 34547102517 scopus 로고    scopus 로고
    • Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines
    • Laurent A, Mistretta F, Bottigioli D, et al. Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines. Vaccine 2007; 25: 6423-30.
    • (2007) Vaccine , vol.25 , pp. 6423-6430
    • Laurent, A.1    Mistretta, F.2    Bottigioli, D.3
  • 94
    • 84869463636 scopus 로고    scopus 로고
    • Analytical Modeling and Evaluation of Microneedles Apparatus with Deformable Soft Tissues for Biomedical Applications
    • Boonma A, Narayan RJ and Lee Y-S. Analytical Modeling and Evaluation of Microneedles Apparatus with Deformable Soft Tissues for Biomedical Applications. Computer-aide designs and applications 2013; 10(1): 139-157.
    • (2013) Computer-aide designs and applications , vol.10 , Issue.1 , pp. 139-157
    • Boonma, A.1    Narayan, R.J.2    Lee, Y.-S.3
  • 95
    • 4544385215 scopus 로고    scopus 로고
    • Microneedle insertion force reduction using vibratory actuation
    • Yang M, Zahn JD. Microneedle insertion force reduction using vibratory actuation. Biomed Microdevices 2004; 6: 177-82.
    • (2004) Biomed Microdevices , vol.6 , pp. 177-182
    • Yang, M.1    Zahn, J.D.2
  • 96
    • 79960557083 scopus 로고    scopus 로고
    • Infusion pressure and pain during microneedle injection into skin of human Subjects
    • Gupta J, Park SS, Bondy B, Felner EI, Prausnitz MR. Infusion pressure and pain during microneedle injection into skin of human Subjects. Biomaterials 2011; 32: 6823-6831.
    • (2011) Biomaterials , vol.32 , pp. 6823-6831
    • Gupta, J.1    Park, S.S.2    Bondy, B.3    Felner, E.I.4    Prausnitz, M.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.