메뉴 건너뛰기




Volumn , Issue , 2013, Pages 109-114

Mr-compatible biopsy needle with enhanced tip force sensing

Author keywords

[No Author keywords available]

Indexed keywords

BENDING STRAIN; BIOPSY NEEDLE; DYNAMIC FORCES; EXTERNAL FORCE; INTERACTION FORCES; MICRO-MACHINED; MR-COMPATIBLE; STRAIN SENSITIVITY;

EID: 84881464355     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/WHC.2013.6548393     Document Type: Conference Paper
Times cited : (33)

References (34)
  • 1
    • 33846044602 scopus 로고    scopus 로고
    • Needle insertion into soft tissue: A survey
    • N. Abolhassani, R. Patel, and M. Moallem. Needle insertion into soft tissue: a survey. Med Eng Phys, 29(4):413-31, 2007.
    • (2007) Med Eng Phys , vol.29 , Issue.4 , pp. 413-31
    • Abolhassani, N.1    Patel, R.2    Moallem, M.3
  • 2
    • 36148973958 scopus 로고    scopus 로고
    • In vivo model estimation and haptic characterization of needle insertions
    • L. Barbe, B. Bayle, M. de Mathelin, and A. Gangi. In vivo model estimation and haptic characterization of needle insertions. Int J Robot Res, 26(11-12):1283-1301, 2007.
    • (2007) Int J Robot Res , vol.26 , Issue.11-12 , pp. 1283-1301
    • Barbe, L.1    Bayle, B.2    De Mathelin, M.3    Gangi, A.4
  • 3
    • 84875866717 scopus 로고    scopus 로고
    • In vivo validation of a system for haptic feedback of tool vibrations in robotic surgery
    • [Online, DOI 10. 1007/s00464-012-2452-8]
    • K. Bark, W. McMahan, A. Remington, J. Gerwirtz, A. Wedmid, D. I. Lee, and K. J. Kuchenbecker. In vivo validation of a system for haptic feedback of tool vibrations in robotic surgery. Surgical Endoscopy, 2012. [Online, DOI 10. 1007/s00464-012-2452-8].
    • (2012) Surgical Endoscopy
    • Bark, K.1    McMahan, W.2    Remington, A.3    Gerwirtz, J.4    Wedmid, A.5    Lee, D.I.6    Kuchenbecker, K.J.7
  • 4
    • 57649098961 scopus 로고    scopus 로고
    • On the gage factor for optical fiber grating strain gages
    • page Paper ID 5166
    • R. J. Black, D. Zare, L. Oblea, Y.-L. Park, B. Moslehi, and C. Neslen. On the gage factor for optical fiber grating strain gages. In SAMPE, volume 53, page Paper ID 5166, 2008.
    • (2008) SAMPE , vol.53
    • Black, R.J.1    Zare, D.2    Oblea, L.3    Park, Y.-L.4    Moslehi, B.5    Neslen, C.6
  • 5
    • 35248858919 scopus 로고    scopus 로고
    • Transperineal prostate biopsy under magnetic resonance image guidance: A needle placement accuracy study
    • P. Blumenfeld, N. Hata, S. DiMaio, K. Zou, S. Haker, G. Fichtinger, and C. Tempany. Transperineal Prostate Biopsy Under Magnetic Resonance Image Guidance: A Needle Placement Accuracy Study. J Magn Reson Im, 26:688694, 2007.
    • (2007) J Magn Reson im , vol.26 , pp. 688694
    • Blumenfeld, P.1    Hata, N.2    Dimaio, S.3    Zou, K.4    Haker, S.5    Fichtinger, G.6    Tempany, C.7
  • 6
    • 0031166845 scopus 로고    scopus 로고
    • Simultaneous measurement of strain and temperature using the first-and second-order diffraction wavelengths of Bragg gratings
    • G. Brady, K. Kalli, D. Webb, D. Jackson, L. Reekie, and J. Archambault. Simultaneous measurement of strain and temperature using the first-and second-order diffraction wavelengths of Bragg gratings. IEE Proc Optoelectron, 144(3):156-161, 1997.
    • (1997) IEE Proc Optoelectron , vol.144 , Issue.3 , pp. 156-161
    • Brady, G.1    Kalli, K.2    Webb, D.3    Jackson, D.4    Reekie, L.5    Archambault, J.6
  • 9
    • 84862600973 scopus 로고    scopus 로고
    • Experimental evaluation of a coaxial needle insertion assistant with enhanced force feedback
    • Jan
    • D. De Lorenzo, Y. Koseki, E. De Momi, K. Chinzei, and A. M. Okamura. Experimental evaluation of a coaxial needle insertion assistant with enhanced force feedback. In IEEE EMBC, volume 2011, pages 3447-50, Jan. 2011.
    • (2011) IEEE EMBC Volume 2011 , pp. 3447-50
    • De Lorenzo, D.1    Koseki, Y.2    De Momi, E.3    Chinzei, K.4    Okamura, A.M.5
  • 10
    • 0142258214 scopus 로고    scopus 로고
    • Needle insertion modeling and simulation
    • S. DiMaio and S. Salcudean. Needle insertion modeling and simulation. IEEE T Robotic Autom, 19(5):864-875, 2003.
    • (2003) IEEE T Robotic Autom , vol.19 , Issue.5 , pp. 864-875
    • Dimaio, S.1    Salcudean, S.2
  • 14
    • 0031212257 scopus 로고    scopus 로고
    • Fiber bragg grating technology fundamentals and overview
    • K. O. Hill and G. Meltz. Fiber Bragg grating technology fundamentals and overview. J Lightwave Technol, 15:1263-1276, 1997.
    • (1997) J Lightwave Technol , vol.15 , pp. 1263-1276
    • Hill, K.O.1    Meltz, G.2
  • 15
    • 34247633744 scopus 로고    scopus 로고
    • Reality-based estimation of needle and soft-tissue interaction for accurate haptic feedback in prostate brachytherapy simulation
    • J. Hing, A. Brooks, and J. Desai. Reality-based estimation of needle and soft-tissue interaction for accurate haptic feedback in prostate brachytherapy simulation. Robotics Research, STAR 28:34-48, 2007.
    • (2007) Robotics Research, STAR , vol.28 , pp. 34-48
    • Hing, J.1    Brooks, A.2    Desai, J.3
  • 16
    • 67749130638 scopus 로고    scopus 로고
    • A sub-millimetric, 0. 25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery
    • I. Iordachita, Z. Sun, M. Balicki, J. U. Kang, S. J. Phee, J. Handa, P. Gehlbach, and R. Taylor. A sub-millimetric, 0. 25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. Int J CARS, 4(4):383-390, 2009.
    • (2009) Int J CARS , vol.4 , Issue.4 , pp. 383-390
    • Iordachita, I.1    Sun, Z.2    Balicki, M.3    Kang, J.U.4    Phee, S.J.5    Handa, J.6    Gehlbach, P.7    Taylor, R.8
  • 17
    • 40449108532 scopus 로고    scopus 로고
    • Tactile displays: Guidance for their design and application
    • L. A. Jones and N. B. Sarter. Tactile Displays: Guidance for Their Design and Application. Human Factors, 50(1):90-111, 2008.
    • (2008) Human Factors , vol.50 , Issue.1 , pp. 90-111
    • Jones, L.A.1    Sarter, N.B.2
  • 18
    • 84974678912 scopus 로고    scopus 로고
    • Measurement of the tip and friction force acting on a needle during penetration
    • Springer-Verlag Berlin Heidelberg
    • H. Kataoka, T. Washio, K. Chinzei, K. Mizuhara, C. Simone, and A. M. Okamura. Measurement of the Tip and Friction Force Acting on a Needle during Penetration. In MICCAI, pages 216-223. Springer-Verlag Berlin Heidelberg, 2002.
    • (2002) MICCAI , pp. 216-223
    • Kataoka, H.1    Washio, T.2    Chinzei, K.3    Mizuhara, K.4    Simone, C.5    Okamura, A.M.6
  • 19
    • 33745714414 scopus 로고    scopus 로고
    • Combined diffusion-weighted and dynamic contrast-enhanced MRI for prostate cancer diagnosis-correlation with biopsy and histopathology
    • P. Kozlowski, S. D. Chang, E. C. Jones, K. W. Berean, H. Chen, and S. L. Goldenberg. Combined diffusion-weighted and dynamic contrast-enhanced MRI for prostate cancer diagnosis-correlation with biopsy and histopathology. J Magn Reson Im, 24(1):108-13, 2006.
    • (2006) J Magn Reson im , vol.24 , Issue.1 , pp. 108-13
    • Kozlowski, P.1    Chang, S.D.2    Jones, E.C.3    Berean, K.W.4    Chen, H.5    Goldenberg, S.L.6
  • 21
    • 84867438731 scopus 로고    scopus 로고
    • Combining shape sensor and haptic sensors for highly flexible single port system using Fiber Bragg sensor technology
    • July
    • C. Ledermann, J. Hergenhan, O. Weede, and H. Woern. Combining shape sensor and haptic sensors for highly flexible single port system using Fiber Bragg sensor technology. In IEEE/ASME MESA, pages 196-201, July 2012.
    • (2012) IEEE/ASME MESA , pp. 196-201
    • Ledermann, C.1    Hergenhan, J.2    Weede, O.3    Woern, H.4
  • 22
    • 79955893756 scopus 로고    scopus 로고
    • Fiber grating sensors in medicine: Current and emerging applications
    • V. Mishra, N. Singh, U. Tiwari, and P. Kapur. Fiber grating sensors in medicine: Current and emerging applications. Sensor Actuat A-Phys, 167(2):279-290, 2011.
    • (2011) Sensor Actuat A-Phys , vol.167 , Issue.2 , pp. 279-290
    • Mishra, V.1    Singh, N.2    Tiwari, U.3    Kapur, P.4
  • 23
    • 84863917153 scopus 로고    scopus 로고
    • Highly scalable operational sensor system for harsh environment applications
    • [In Press]
    • B. Moslehi, R. J. Black, J. M. Costa, V. Sotoudeh, and F. Faridian. Highly scalable operational sensor system for harsh environment applications. In SAMPE, 2012. [In Press].
    • (2012) SAMPE
    • Moslehi, B.1    Black, R.J.2    Costa, J.M.3    Sotoudeh, V.4    Faridian, F.5
  • 24
    • 84875862376 scopus 로고    scopus 로고
    • Force feedback and sensory substitution for robot-assisted surgery
    • In J. Rosen, B. Hannaford and R. Satava, editors, Springer, New York, NY, USA
    • A. Okamura, L. Verner, T. Yamamoto, J. Gwilliam, and P. Griffiths. Force feedback and sensory substitution for robot-assisted surgery. In J. Rosen, B. Hannaford, and R. Satava, editors, Surgical Robotics: Systems, Applications, and Visions, pages 419-448. Springer, New York, NY, USA, 2011.
    • (2011) Surgical Robotics: Systems, Applications and Visions , pp. 419-448
    • Okamura, A.1    Verner, L.2    Yamamoto, T.3    Gwilliam, J.4    Griffiths, P.5
  • 25
    • 58149215973 scopus 로고    scopus 로고
    • Haptic feedback in robot-assisted minimally invasive surgery
    • A. M. Okamura. Haptic feedback in robot-assisted minimally invasive surgery. Curr Opin Urol, 19(1):102-7, 2009.
    • (2009) Curr Opin Urol , vol.19 , Issue.1 , pp. 102-7
    • Okamura, A.M.1
  • 26
    • 3042572777 scopus 로고    scopus 로고
    • Force modeling for needle insertion into soft tissue
    • A. M. Okamura, C. Simone, and M. D. O'Leary. Force modeling for needle insertion into soft tissue. IEEE T Bio-Med Eng, 51(10):1707-16, 2004.
    • (2004) IEEE T Bio-Med Eng , vol.51 , Issue.10 , pp. 1707-16
    • Okamura, A.M.1    Simone, C.2    O'leary, M.D.3
  • 28
    • 0036057655 scopus 로고    scopus 로고
    • Modeling of needle insertion forces for robot-assisted percutaneous therapy
    • C. Simone and A. Okamura. Modeling of needle insertion forces for robot-assisted percutaneous therapy. In IEEE ICRA, volume 2, pages 2085-2091, 2002.
    • (2002) IEEE ICRA , vol.2 , pp. 2085-2091
    • Simone, C.1    Okamura, A.2
  • 31
    • 35348853696 scopus 로고    scopus 로고
    • Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: A review study
    • N. V. Tsekos, A. Khanicheh, E. Christoforou, and C. Mavroidis. Magnetic Resonance-Compatible Robotic and Mechatronics Systems for Image-Guided Interventions and Rehabilitation: A Review Study. Annu Rev Biomed Eng, 9:351-387, 2007.
    • (2007) Annu Rev Biomed Eng , vol.9 , pp. 351-387
    • Tsekos, N.V.1    Khanicheh, A.2    Christoforou, E.3    Mavroidis, C.4
  • 32
    • 67651244385 scopus 로고    scopus 로고
    • The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: A current review
    • O. van der Meijden and M. Schijven. The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review. Surgical Endoscopy, 23(6):1180-90, 2009.
    • (2009) Surgical Endoscopy , vol.23 , Issue.6 , pp. 1180-90
    • Meijden Der O.Van1    Schijven, M.2
  • 33
    • 20344383988 scopus 로고    scopus 로고
    • Needle force sensor robust and sensitive detection of the instant of needle puncture
    • T. Washio and K. Chinzei. Needle Force Sensor Robust and Sensitive Detection of the Instant of Needle Puncture. In MICCAI, pages 113-120, 2004.
    • (2004) MICCAI , pp. 113-120
    • Washio, T.1    Chinzei, K.2
  • 34
    • 27744574579 scopus 로고    scopus 로고
    • On SDM/WDM FBG sensor net for shape detection of endoscope
    • L. Zhang, J. Qian, Y. Zhang, and L. Shen. On SDM/WDM FBG sensor net for shape detection of endoscope. In IEEE ICMA, volume 4, pages 1986-1991, 2005.
    • (2005) IEEE ICMA , vol.4 , pp. 1986-1991
    • Zhang, L.1    Qian, J.2    Zhang, Y.3    Shen, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.