Volumn 26 III, Issue , 2004, Pages 2022-2025

Development of an MR-compatible optical force sensor

Author keywords

MR compatible force sensor; MRI; Optical micrometry

Indexed keywords

BRAIN; DYNAMOMETERS; LENSES; LIGHT EMITTING DIODES; MAGNETIC RESONANCE IMAGING; NETWORKS (CIRCUITS); NUCLEAR MAGNETIC RESONANCE; OPTICAL FIBERS; PHOTODIODES; SIGNAL TO NOISE RATIO;

EID: 11144315470     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (7)

References (9)
  • 1
    • 84957057529 scopus 로고    scopus 로고
    • MR compatibility of mechatronic devices: Design criteria
    • K. Chinzei et al., "MR compatibility of mechatronic devices: Design criteria," in Proc. of Second Int'l Conf. on MICCAI, 1999, pp. 1020-1031.
    • (1999) Proc. of Second Int'l Conf. on MICCAI , pp. 1020-1031
    • Chinzei, K.1
  • 2
    • 0029422530 scopus 로고
    • Development of an MRI-compatible needle insertion manipulator for stereotactic nuerosurgery
    • K. Masamune et al., "Development of an MRI-compatible needle insertion manipulator for stereotactic nuerosurgery," J. of Image Guided Surgery, vol. 1, pp. 242-248, 1995.
    • (1995) J. of Image Guided Surgery , vol.1 , pp. 242-248
    • Masamune, K.1
  • 3
    • 84945573291 scopus 로고    scopus 로고
    • MR compatible surgical assist robot: System integration and preliminary feasibility study
    • K. Chinzei et al., "MR compatible surgical assist robot: system integration and preliminary feasibility study," in Proc. of Third Int'l Conf. on MICCAI, 2000, pp. 921-930.
    • (2000) Proc. of Third Int'l Conf. on MICCAI , pp. 921-930
    • Chinzei, K.1
  • 4
    • 0031908578 scopus 로고    scopus 로고
    • Elasticity reconstructive imaging by means of stimulated echo MRI
    • T. L. Chenevert et al., "Elasticity reconstructive imaging by means of stimulated echo MRI," J. of Magn. Reson. M ed., vol. 39, pp. 482-490, 1998.
    • (1998) J. of Magn. Reson. Med. , vol.39 , pp. 482-490
    • Chenevert, T.L.1
  • 5
    • 0033982836 scopus 로고    scopus 로고
    • Cortical activity in precision-versus power-grip tasks: An fMRI study
    • H. H. Ehrsson et al., "Cortical activity in precision-versus power-grip tasks: An fMRI study," J. of Neurophysiol, vol. 83, no. 1, pp. 528-536, 2000.
    • (2000) J. of Neurophysiol , vol.83 , Issue.1 , pp. 528-536
    • Ehrsson, H.H.1
  • 6
    • 0034663457 scopus 로고    scopus 로고
    • Simultaneous measurement of human joint force, surface electromyograms, and functional MRI-measured brain activation
    • J. Z. Liu et al., "Simultaneous measurement of human joint force, surface electromyograms, and functional MRI-measured brain activation," J. of Neurosciece Method, vol. 101, pp. 49-57, 2000.
    • (2000) J. of Neurosciece Method , vol.101 , pp. 49-57
    • Liu, J.Z.1
  • 7
    • 11144257082 scopus 로고    scopus 로고
    • Development of an optical 2-axis force sensor usable in MRI environments
    • M. Tada et al., "Development of an optical 2-axis force sensor usable in MRI environments," in Pmc. of Int'l Conf. on Sensors, 2002.
    • (2002) Pmc. of Int'l Conf. on Sensors
    • Tada, M.1
  • 8
    • 11144323802 scopus 로고    scopus 로고
    • An optical 6-axis force sensor for brain function analysis using fMRI
    • N. Takahashi et al., "An optical 6-axis force sensor for brain function analysis using fMRI," in Proc. of Int'l Conf. on Sensors, 2003.
    • (2003) Proc. of Int'l Conf. on Sensors
    • Takahashi, N.1
  • 9
    • 0025638374 scopus 로고
    • Development of optical 6-axial force sensor and its signal calibration considering non-linear interference
    • S. Hirose et al., "Development of optical 6-axial force sensor and its signal calibration considering non-linear interference," in Proc. of Int'l Conf. on Advanced Robotics, 1990, pp. 46-53.
    • (1990) Proc. of Int'l Conf. on Advanced Robotics , pp. 46-53
    • Hirose, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.