메뉴 건너뛰기




Volumn 26, Issue 3, 2007, Pages 688-694

Transperineal prostate biopsy under magnetic resonance image guidance: A needle placement accuracy study

Author keywords

Accuracy assessment; Biopsy; Intraoperative MRI; Needle misplacement; Prostate

Indexed keywords

ACCURACY; ADULT; ANALYTICAL ERROR; ARTICLE; CANCER DIAGNOSIS; CLINICAL ARTICLE; DIAGNOSTIC APPROACH ROUTE; HUMAN; MALE; NEEDLE BIOPSY; NUCLEAR MAGNETIC RESONANCE IMAGING; PERINEUM; PHANTOM; PRIORITY JOURNAL; PROSTATE BIOPSY; PROSTATE CANCER; AGED; ARTIFACT; IMAGE QUALITY; METHODOLOGY; MIDDLE AGED; NEEDLE; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PATHOLOGY; PROSTATE TUMOR; PROSTATECTOMY; REPRODUCIBILITY; RETROSPECTIVE STUDY;

EID: 35248858919     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21067     Document Type: Article
Times cited : (69)

References (28)
  • 1
    • 0041830469 scopus 로고    scopus 로고
    • Annual report to the nation on the status of cancer, 1975-2000, featuring the uses of surveillance data for cancer prevention and control
    • Weir HK, Thun MJ, Hankey BF, et al. Annual report to the nation on the status of cancer, 1975-2000, featuring the uses of surveillance data for cancer prevention and control. J Natl Cancer Inst 2003; 95:1276-1299.
    • (2003) J Natl Cancer Inst , vol.95 , pp. 1276-1299
    • Weir, H.K.1    Thun, M.J.2    Hankey, B.F.3
  • 2
    • 12344276502 scopus 로고    scopus 로고
    • MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: Initial results
    • Beyersdorff D, Winkel A, Hamm B, Lenk S, Loening SA, Taupitz M. MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results. Radiology 2005;234:576-581.
    • (2005) Radiology , vol.234 , pp. 576-581
    • Beyersdorff, D.1    Winkel, A.2    Hamm, B.3    Lenk, S.4    Loening, S.A.5    Taupitz, M.6
  • 3
    • 0032838888 scopus 로고    scopus 로고
    • Sensitivity and specificity of sextant biopsies in the detection of prostate cancer: Preliminary report
    • Terris MK. Sensitivity and specificity of sextant biopsies in the detection of prostate cancer: preliminary report. Urology 1999;54: 486-489.
    • (1999) Urology , vol.54 , pp. 486-489
    • Terris, M.K.1
  • 4
    • 0025819478 scopus 로고
    • The American-Cancer-Society National Prostate-Cancer detection project - findings on the detection of early prostate cancer in 2425 men
    • Mettlin C, Lee F, Drago J, Murphy GP. The American-Cancer-Society National Prostate-Cancer detection project - findings on the detection of early prostate cancer in 2425 men. Cancer 1991;67: 2949-2958.
    • (1991) Cancer , vol.67 , pp. 2949-2958
    • Mettlin, C.1    Lee, F.2    Drago, J.3    Murphy, G.P.4
  • 5
    • 0030862771 scopus 로고    scopus 로고
    • The sextant protocol for ultrasound-guided core biopsies of the prostate underestimates the presence of cancer
    • Norberg M, Egevad L, Holmberg L, Sparen P, Norlen BJ, Busch C. The sextant protocol for ultrasound-guided core biopsies of the prostate underestimates the presence of cancer. Urology 1997;50: 562-566.
    • (1997) Urology , vol.50 , pp. 562-566
    • Norberg, M.1    Egevad, L.2    Holmberg, L.3    Sparen, P.4    Norlen, B.J.5    Busch, C.6
  • 6
    • 0033927199 scopus 로고    scopus 로고
    • Transperineal magnetic resonance image guided prostate biopsy
    • D'Amico AV, Tempany CM, Cormack R, et al. Transperineal magnetic resonance image guided prostate biopsy. J Urol 2000;164: 385-387.
    • (2000) J Urol , vol.164 , pp. 385-387
    • D'Amico, A.V.1    Tempany, C.M.2    Cormack, R.3
  • 7
    • 19944429876 scopus 로고    scopus 로고
    • MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: Technique and preliminary results
    • Zangos S, Eichler K, Engelmann K, et al. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results. Eur Radiol 2005;15:174-182.
    • (2005) Eur Radiol , vol.15 , pp. 174-182
    • Zangos, S.1    Eichler, K.2    Engelmann, K.3
  • 8
    • 0034984062 scopus 로고    scopus 로고
    • MR imaging-guided prostate biopsy with surgical navigation software: Device validation and feasibility
    • Hata N, Jinzaki M, Kacher D, et al. MR imaging-guided prostate biopsy with surgical navigation software: device validation and feasibility. Radiology 2001;220:263-268.
    • (2001) Radiology , vol.220 , pp. 263-268
    • Hata, N.1    Jinzaki, M.2    Kacher, D.3
  • 9
    • 0036672023 scopus 로고    scopus 로고
    • Magnetic resonance imaging of prostate cancer
    • Adusumilli S, Pretorius ES. Magnetic resonance imaging of prostate cancer. Semin Urol Oncol 2002;20:192-210.
    • (2002) Semin Urol Oncol , vol.20 , pp. 192-210
    • Adusumilli, S.1    Pretorius, E.S.2
  • 10
    • 0033912355 scopus 로고    scopus 로고
    • Sextant localization of prostate cancer: Comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology
    • Wefer AE, Hricak H, Vigneron DB, et al. Sextant localization of prostate cancer: comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology. J Urol 2000;164:400-404.
    • (2000) J Urol , vol.164 , pp. 400-404
    • Wefer, A.E.1    Hricak, H.2    Vigneron, D.B.3
  • 12
    • 11144356849 scopus 로고    scopus 로고
    • Optimized prostate biopsy via a statistical atlas of cancer spatial distribution
    • Shen D, Lao Z, Zeng J, et al. Optimized prostate biopsy via a statistical atlas of cancer spatial distribution. Med Image Anal 2004;8:139-150.
    • (2004) Med Image Anal , vol.8 , pp. 139-150
    • Shen, D.1    Lao, Z.2    Zeng, J.3
  • 13
    • 4243072965 scopus 로고    scopus 로고
    • System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner
    • Susil RC, Camphausen K, Choyke P, et al. System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner. Magn Reson Med 2004;52:683-687.
    • (2004) Magn Reson Med , vol.52 , pp. 683-687
    • Susil, R.C.1    Camphausen, K.2    Choyke, P.3
  • 15
    • 20444448852 scopus 로고    scopus 로고
    • Interactive simulation of needle insertion models
    • DiMaio SP, Salcudean SE. Interactive simulation of needle insertion models. IEEE Trans Biomed Eng 2005;52:1167-1179.
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1167-1179
    • DiMaio, S.P.1    Salcudean, S.E.2
  • 16
    • 20444437666 scopus 로고    scopus 로고
    • Needle steering and motion planning in soft tissues
    • DiMaio SP, Salcudean SE. Needle steering and motion planning in soft tissues. IEEE Trans Biomed Eng 2005;52:965-974.
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 965-974
    • DiMaio, S.P.1    Salcudean, S.E.2
  • 17
    • 0000969292 scopus 로고
    • Closed form solution of absolute orientation using orthonormal matrices
    • Horn BKP, Hilden HM, Negahdaripour S. Closed form solution of absolute orientation using orthonormal matrices. J Optical Soc A 1988;4:51127-51135.
    • (1988) J Optical Soc A , vol.4 , pp. 51127-51135
    • Horn, B.K.P.1    Hilden, H.M.2    Negahdaripour, S.3
  • 19
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 1996;23:815-850.
    • (1996) Med Phys , vol.23 , pp. 815-850
    • Schenck, J.F.1
  • 20
    • 3042824535 scopus 로고    scopus 로고
    • Endorectal MRI for prediction of tumor site, tumor size, and local extension of prostate cancer
    • Nakashima J, Tanimoto A, Imai Y, et al. Endorectal MRI for prediction of tumor site, tumor size, and local extension of prostate cancer. Urology. 2004;64:101-105.
    • (2004) Urology , vol.64 , pp. 101-105
    • Nakashima, J.1    Tanimoto, A.2    Imai, Y.3
  • 21
    • 1842476743 scopus 로고    scopus 로고
    • Deformable image registration for the use of magnetic resonance spectroscopy in prostate treatment planning
    • Wu X, Dibiase SJ, Gullapalli R, Yu CX. Deformable image registration for the use of magnetic resonance spectroscopy in prostate treatment planning. Int J Radiat Oncol Biol Phys 2004;58:1577-1583.
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 1577-1583
    • Wu, X.1    Dibiase, S.J.2    Gullapalli, R.3    Yu, C.X.4
  • 24
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    • Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR Am J Roentgenol 1996;166:1337-1345.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3    Petersilge, C.A.4    Chao, C.P.5    Haaga, J.R.6
  • 26
    • 0031934809 scopus 로고    scopus 로고
    • Interventional MRI at high-field (1.5 T): Needle artifacts
    • Liu H, Martin AJ, Truwit CL. Interventional MRI at high-field (1.5 T): needle artifacts. J Magn Reson Imaging 1998;8:214-219.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 214-219
    • Liu, H.1    Martin, A.J.2    Truwit, C.L.3
  • 28
    • 13244277937 scopus 로고    scopus 로고
    • Design of a novel MRI compatible manipulator for image guided prostate intervention
    • Krieger A, Susil RC, Menard C, et al. Design of a novel MRI compatible manipulator for image guided prostate intervention. IEEE Trans Biomed Eng 2005;52:306-313.
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 306-313
    • Krieger, A.1    Susil, R.C.2    Menard, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.