-
1
-
-
84865075321
-
Biopharmaceucals: an overview
-
Kluwer Academic Publishers, Dordrecht, The Netherlands, G. Walsh, B. Murphy (Eds.)
-
Walsh G. Biopharmaceucals: an overview. Biopharmaceuticals: An Industrial Perspective 1999, 1-34. Kluwer Academic Publishers, Dordrecht, The Netherlands. G. Walsh, B. Murphy (Eds.).
-
(1999)
Biopharmaceuticals: An Industrial Perspective
, pp. 1-34
-
-
Walsh, G.1
-
2
-
-
84865085974
-
Pharmaceuticals, biologics and biopharmaceuticals
-
Wiley, West Sussex, England
-
Walsh G. Pharmaceuticals, biologics and biopharmaceuticals. Pharmaceutical Biotechnology: Concepts and Applications 2007, Wiley, West Sussex, England, pp. 1-11.
-
(2007)
Pharmaceutical Biotechnology: Concepts and Applications
, pp. 1-11
-
-
Walsh, G.1
-
3
-
-
84872829927
-
-
(consulted in November).
-
(consulted in November 2011). http://www.imshealth.com/.
-
(2011)
-
-
-
4
-
-
84872828515
-
-
(consulted in November
-
(consulted in November 2011). http://www.portfoliomanagementsolutions.com/the-organization-of-pharmaceutical-rd/small-molecule-drugs-versus-biomolecular-drugs-biologics/.
-
(2011)
-
-
-
5
-
-
84856870926
-
Current applications of UHPLC in biotechnology. Part I. Peptide mapping and amino acid analysis
-
Krull I.S., Rathore A., Wheat T.E. Current applications of UHPLC in biotechnology. Part I. Peptide mapping and amino acid analysis. LC-GC N. Am. 2011, 29:838-848.
-
(2011)
LC-GC N. Am.
, vol.29
, pp. 838-848
-
-
Krull, I.S.1
Rathore, A.2
Wheat, T.E.3
-
6
-
-
79955464639
-
Intact protein analysis in the biopharmaceutical field
-
Staub A., Guillarme D., Schappler J., Veuthey J.L., Rudaz S. Intact protein analysis in the biopharmaceutical field. J. Pharm. Biomed. Anal. 2011, 55:810-822.
-
(2011)
J. Pharm. Biomed. Anal.
, vol.55
, pp. 810-822
-
-
Staub, A.1
Guillarme, D.2
Schappler, J.3
Veuthey, J.L.4
Rudaz, S.5
-
7
-
-
34447262161
-
Capillary electrophoresis-mass spectrometry for the analysis of intact proteins
-
Haselberg R., de Jong G.J., Somsen G.W. Capillary electrophoresis-mass spectrometry for the analysis of intact proteins. J. Chromatogr. A 2007, 1159:81-109.
-
(2007)
J. Chromatogr. A
, vol.1159
, pp. 81-109
-
-
Haselberg, R.1
de Jong, G.J.2
Somsen, G.W.3
-
8
-
-
18444392433
-
Protein profiling by capillary isoelectric focusing, reversed-phase liquid chromatography, and mass spectrometry
-
Zhou F., Johnston M.V. Protein profiling by capillary isoelectric focusing, reversed-phase liquid chromatography, and mass spectrometry. Electrophoresis 2005, 26:1383-1388.
-
(2005)
Electrophoresis
, vol.26
, pp. 1383-1388
-
-
Zhou, F.1
Johnston, M.V.2
-
9
-
-
78650266493
-
Capillary electrophoresis-mass spectrometry for the analysis of intact proteins 2007-2010
-
Haselberg R., de Jong G.J., Somsen G.W. Capillary electrophoresis-mass spectrometry for the analysis of intact proteins 2007-2010. Electrophoresis 2011, 32:66-82.
-
(2011)
Electrophoresis
, vol.32
, pp. 66-82
-
-
Haselberg, R.1
de Jong, G.J.2
Somsen, G.W.3
-
10
-
-
26444539668
-
Orthogonality of separation in two-dimensional liquid chromatography
-
Gilar M., Olivova P., Daly A.E., Gebler J.C. Orthogonality of separation in two-dimensional liquid chromatography. Anal. Chem. 2005, 77:6426-6434.
-
(2005)
Anal. Chem.
, vol.77
, pp. 6426-6434
-
-
Gilar, M.1
Olivova, P.2
Daly, A.E.3
Gebler, J.C.4
-
11
-
-
84865083110
-
HPLC of peptides and proteins, unit 8.7
-
John Wiley & Sons, Inc.
-
Boysen R.I., Hearn M.T.W. HPLC of peptides and proteins, unit 8.7. Current Protocols in Protein Science 2001, John Wiley & Sons, Inc., pp. 3-23.
-
(2001)
Current Protocols in Protein Science
, pp. 3-23
-
-
Boysen, R.I.1
Hearn, M.T.W.2
-
12
-
-
70350157913
-
Analytical method validation for biotechnology proteins, peptides, and antibodies
-
(Chromatographyonline)
-
Swartz M., Krull I. Analytical method validation for biotechnology proteins, peptides, and antibodies. LC-GC 2009, http://chromatographyonline.findanalytichem.com/lcgc/ (Chromatographyonline).
-
(2009)
LC-GC
-
-
Swartz, M.1
Krull, I.2
-
13
-
-
84872830132
-
-
ICH Harmonised Tripartite Guideline, Validation of Analytical Procedures: Text and Methodology Q2(R1)
-
ICH Harmonised Tripartite Guideline, Validation of Analytical Procedures: Text and Methodology Q2(R1), http://www.ich.org/.
-
-
-
-
14
-
-
84872829653
-
-
ICH Harmonised Tripartite Guideline, Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products Q6B
-
ICH Harmonised Tripartite Guideline, Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products Q6B, http://www.ich.org/.
-
-
-
-
15
-
-
0029787269
-
High resolution reversed phase high performance liquid chromatography of peptides and proteins
-
Aguilar M.I., Hearn M.T.W. High resolution reversed phase high performance liquid chromatography of peptides and proteins. Meth. Enzymol. 1996, 270:3-26.
-
(1996)
Meth. Enzymol.
, vol.270
, pp. 3-26
-
-
Aguilar, M.I.1
Hearn, M.T.W.2
-
16
-
-
0029841273
-
Analysis of peptides by high performance liquid chromatography
-
Mant C.T., Hodges R.S. Analysis of peptides by high performance liquid chromatography. Meth. Enzymol. 1996, 271:3-50.
-
(1996)
Meth. Enzymol.
, vol.271
, pp. 3-50
-
-
Mant, C.T.1
Hodges, R.S.2
-
17
-
-
14744275762
-
-
Human Press, Totowa, NJ
-
Aguilar M.I. HPLC of Peptides and Proteins, Methods and Protocols 2004, Human Press, Totowa, NJ, pp. 9-22.
-
(2004)
HPLC of Peptides and Proteins, Methods and Protocols
, pp. 9-22
-
-
Aguilar, M.I.1
-
18
-
-
0017772694
-
Separation of amino acids and peptides on non-polar stationary phases by HPLC
-
Molnár I., Cs Horváth Separation of amino acids and peptides on non-polar stationary phases by HPLC. J. Chromatogr. 1977, 142:623-640.
-
(1977)
J. Chromatogr.
, vol.142
, pp. 623-640
-
-
Molnár, I.1
Horváth, C.2
-
20
-
-
0025896553
-
Design requirements of silica-based matrices for biopolymer chromatography
-
Henry M. Design requirements of silica-based matrices for biopolymer chromatography. J. Chromatogr. 1991, 544:413-443.
-
(1991)
J. Chromatogr.
, vol.544
, pp. 413-443
-
-
Henry, M.1
-
21
-
-
0025762563
-
Comparison of silica-based cyanopropyl and octyl reversed phase packings for the separation of peptides and proteins
-
Zhou N.E., Mant C.T., Kirkland J.J., Hodges R.S. Comparison of silica-based cyanopropyl and octyl reversed phase packings for the separation of peptides and proteins. J. Chromatogr. 1991, 548:179-193.
-
(1991)
J. Chromatogr.
, vol.548
, pp. 179-193
-
-
Zhou, N.E.1
Mant, C.T.2
Kirkland, J.J.3
Hodges, R.S.4
-
22
-
-
0027308075
-
Solution structure of human type-α-transforming growth factor determined by heteronuclear NMR spectroscopy and refined by energy minimisation with restraints
-
Moy F.J., Li Y.-C., Rauenbeuhler P., Winkler M.E., Scheraga H.A., Montelione G.T. Solution structure of human type-α-transforming growth factor determined by heteronuclear NMR spectroscopy and refined by energy minimisation with restraints. Biochemistry 1993, 32:7334-7353.
-
(1993)
Biochemistry
, vol.32
, pp. 7334-7353
-
-
Moy, F.J.1
Li, Y.-C.2
Rauenbeuhler, P.3
Winkler, M.E.4
Scheraga, H.A.5
Montelione, G.T.6
-
23
-
-
0027476053
-
High performance liquid chromatography of human glycoprotein hormones
-
Chlenov M.A., Kandyba E.I., Nagornaya L.V., Orlova I.L., Volgin Y.V. High performance liquid chromatography of human glycoprotein hormones. J. Chromatogr. 1993, 631:261-267.
-
(1993)
J. Chromatogr.
, vol.631
, pp. 261-267
-
-
Chlenov, M.A.1
Kandyba, E.I.2
Nagornaya, L.V.3
Orlova, I.L.4
Volgin, Y.V.5
-
24
-
-
0023057921
-
Reversed-phase high performance liquid chromatography of insulin. Resolution and recovery in relation to column geometry and buffer components
-
Welinder B.S., Sorenson H.H., Hansen B. Reversed-phase high performance liquid chromatography of insulin. Resolution and recovery in relation to column geometry and buffer components. J. Chromatogr. 1986, 361:357-363.
-
(1986)
J. Chromatogr.
, vol.361
, pp. 357-363
-
-
Welinder, B.S.1
Sorenson, H.H.2
Hansen, B.3
-
25
-
-
0026084859
-
Use of polymeric reversed-phase columns for the characterisation of polypeptides extracted from human pancreata. II. Effect of the stationary phase
-
Welinder B.S. Use of polymeric reversed-phase columns for the characterisation of polypeptides extracted from human pancreata. II. Effect of the stationary phase. J. Chromatogr. 1991, 542:83-99.
-
(1991)
J. Chromatogr.
, vol.542
, pp. 83-99
-
-
Welinder, B.S.1
-
26
-
-
84872830253
-
-
Amersham Pharmacia Biotech, Amersham Pharmacia Biotech, Purification of Amyloid-β1-42 at High pH Using a Polymer Stationary Phase Application Note 18-1130-92, 1998
-
Amersham Pharmacia Biotech Source 5RPC ST 4.6/150 High Performance Reversed Phase Chromatgoraphy Data File 18-1132-36 1999, Amersham Pharmacia Biotech, Purification of Amyloid-β1-42 at High pH Using a Polymer Stationary Phase Application Note 18-1130-92, 1998.
-
(1999)
Source 5RPC ST 4.6/150 High Performance Reversed Phase Chromatgoraphy Data File 18-1132-36
-
-
-
27
-
-
0027201921
-
Ceramic based particles as chemically stable chromatographic supports
-
Wirth H.J., Eriksson K.O., Holt P., Aguilar M.I., Hearn M.T.W. Ceramic based particles as chemically stable chromatographic supports. J. Chromatogr. 1993, 646:129-141.
-
(1993)
J. Chromatogr.
, vol.646
, pp. 129-141
-
-
Wirth, H.J.1
Eriksson, K.O.2
Holt, P.3
Aguilar, M.I.4
Hearn, M.T.W.5
-
28
-
-
0028851788
-
Chromatography of proteins using polybutadienecoated zirconia
-
Sun L., Carr P.W. Chromatography of proteins using polybutadienecoated zirconia. Anal. Chem. 1995, 67:3717-3721.
-
(1995)
Anal. Chem.
, vol.67
, pp. 3717-3721
-
-
Sun, L.1
Carr, P.W.2
-
29
-
-
0029788971
-
Rapid separations of proteins by liquid chromatography
-
Paliwal S.K., deFrutos M., Regnier F.E. Rapid separations of proteins by liquid chromatography. Meth. Enzymol. 1996, 270:133-151.
-
(1996)
Meth. Enzymol.
, vol.270
, pp. 133-151
-
-
Paliwal, S.K.1
deFrutos, M.2
Regnier, F.E.3
-
30
-
-
0035356574
-
High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies
-
Premstaller A., Oberacher H., Walcher W. High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies. Anal. Chem. 2001, 73:2390-2396.
-
(2001)
Anal. Chem.
, vol.73
, pp. 2390-2396
-
-
Premstaller, A.1
Oberacher, H.2
Walcher, W.3
-
31
-
-
0001178595
-
Simulation as a means of developing an optimized reversed-phase gradient separation
-
Computer
-
Dolan J.W., Snyder L.R., Quarry M.A., Computer Simulation as a means of developing an optimized reversed-phase gradient separation. Chromatographia 1988, 24:261-271.
-
(1988)
Chromatographia
, vol.24
, pp. 261-271
-
-
Dolan, J.W.1
Snyder L.R.Quarry, M.A.2
-
32
-
-
0010007168
-
Developing a gradient elution method for reversed-phase HPLC
-
Dolan J.W., Snyder L.R. Developing a gradient elution method for reversed-phase HPLC. LC-GC 1988, 5:970-978.
-
(1988)
LC-GC
, vol.5
, pp. 970-978
-
-
Dolan, J.W.1
Snyder, L.R.2
-
33
-
-
0002064952
-
Design of optimized high-performance liquid chromatographic gradients for the separation of either small or large molecules. III. An overall strategy and its application to several examples
-
Ghrist B.F.D., Snyder L.R. Design of optimized high-performance liquid chromatographic gradients for the separation of either small or large molecules. III. An overall strategy and its application to several examples. J. Chromatogr. 1988, 459:43-63.
-
(1988)
J. Chromatogr.
, vol.459
, pp. 43-63
-
-
Ghrist, B.F.D.1
Snyder, L.R.2
-
34
-
-
0010039524
-
High-performance liquid chromatography of Thermus aquaticus 50S and 30S ribosomal proteins
-
Molnar I., Boysen R.I., Erdmann V.A. High-performance liquid chromatography of Thermus aquaticus 50S and 30S ribosomal proteins. Chromatographia 1989, 28:39-44.
-
(1989)
Chromatographia
, vol.28
, pp. 39-44
-
-
Molnar, I.1
Boysen, R.I.2
Erdmann, V.A.3
-
36
-
-
9644295485
-
Solvophobic interactions in liquid chromatography with nonpolar stationary phases
-
Horvath C., Melander W., Molnar I. Solvophobic interactions in liquid chromatography with nonpolar stationary phases. J. Chromatogr. 1976, 125:29-156.
-
(1976)
J. Chromatogr.
, vol.125
, pp. 29-156
-
-
Horvath, C.1
Melander, W.2
Molnar, I.3
-
37
-
-
0005834419
-
Liquid chromatography of ionogenic substances with nonpolar stationary phases
-
Horvath C., Melander W., Molnar I. Liquid chromatography of ionogenic substances with nonpolar stationary phases. Anal. Chem. 1977, 49:142-154.
-
(1977)
Anal. Chem.
, vol.49
, pp. 142-154
-
-
Horvath, C.1
Melander, W.2
Molnar, I.3
-
38
-
-
0000760118
-
Gradient elution
-
Academic Press, New York
-
Snyder L.R. Gradient elution. HPLC: Advances and Perspectives 1980, vol. 1:208-316. Academic Press, New York.
-
(1980)
HPLC: Advances and Perspectives
, vol.1
, pp. 208-316
-
-
Snyder, L.R.1
-
39
-
-
0031686359
-
Systematic, computer-assisted optimization of the isolation of Thermus thermophilus 50S ribosomal proteins by reversed-phase high performance liquid chromatography
-
Boysen R.I., Erdmann V.A., Hearn M.T.W. Systematic, computer-assisted optimization of the isolation of Thermus thermophilus 50S ribosomal proteins by reversed-phase high performance liquid chromatography. J. Biochem. Biophys. Methods 1998, 37:69-89.
-
(1998)
J. Biochem. Biophys. Methods
, vol.37
, pp. 69-89
-
-
Boysen, R.I.1
Erdmann, V.A.2
Hearn, M.T.W.3
-
40
-
-
0018250591
-
Reversed phase, high-pressure liquid chromatography of peptides and proteins with ion-pairing reagents
-
Hancock W., Bishop C.A., Prestidge R.L., Harding D.R., Hearn M.T.W. Reversed phase, high-pressure liquid chromatography of peptides and proteins with ion-pairing reagents. Science 1978, 200:1168-1170.
-
(1978)
Science
, vol.200
, pp. 1168-1170
-
-
Hancock, W.1
Bishop, C.A.2
Prestidge, R.L.3
Harding, D.R.4
Hearn, M.T.W.5
-
41
-
-
0001309764
-
Classification of the solvent properties of common liquids
-
Snyder L.R. Classification of the solvent properties of common liquids. J. Chromatogr. 1974, 92:223-230.
-
(1974)
J. Chromatogr.
, vol.92
, pp. 223-230
-
-
Snyder, L.R.1
-
42
-
-
0017982611
-
Classification of the solvent properties of common liquid solvents
-
Snyder L.R. Classification of the solvent properties of common liquid solvents. J. Chromatogr. Sci. 1978, 16:223-234.
-
(1978)
J. Chromatogr. Sci.
, vol.16
, pp. 223-234
-
-
Snyder, L.R.1
-
43
-
-
0000254966
-
Influence of organic modifiers on the retention behaviour in reversed-phase liquid chromatography and its consequences for gradient elution
-
Schoenmakers P.J., Biliet H.A.H., Galan L.D. Influence of organic modifiers on the retention behaviour in reversed-phase liquid chromatography and its consequences for gradient elution. J. Chromatogr. 1979, 185:179-195.
-
(1979)
J. Chromatogr.
, vol.185
, pp. 179-195
-
-
Schoenmakers, P.J.1
Biliet, H.A.H.2
Galan, L.D.3
-
44
-
-
0345713327
-
Eluotropic strength of solvents. Prediction and use in reversed-phase high-performance liquid chromatography
-
Patel H.B., Jefferies T.M. Eluotropic strength of solvents. Prediction and use in reversed-phase high-performance liquid chromatography. J. Chromatogr. 1987, 389:21-32.
-
(1987)
J. Chromatogr.
, vol.389
, pp. 21-32
-
-
Patel, H.B.1
Jefferies, T.M.2
-
45
-
-
0018652362
-
Investigation of the effects of pH and ion-pair formation on the retention of peptides on chemically-bonded hydrocarbonaceous stationary phases
-
Hearn M.T., Grego B., Hancock W. Investigation of the effects of pH and ion-pair formation on the retention of peptides on chemically-bonded hydrocarbonaceous stationary phases. J. Chromatogr. 1979, 185:429-444.
-
(1979)
J. Chromatogr.
, vol.185
, pp. 429-444
-
-
Hearn, M.T.1
Grego, B.2
Hancock, W.3
-
46
-
-
0040101818
-
Retention-optimization strategy for the high-performance liquid chromatographic ion-pair separation of samples containing basic compounds
-
Goldberg A.P., Nowakowska A.E., Antle P.E., Snyder L.R. Retention-optimization strategy for the high-performance liquid chromatographic ion-pair separation of samples containing basic compounds. J. Chromatogr. 1984, 316:241-260.
-
(1984)
J. Chromatogr.
, vol.316
, pp. 241-260
-
-
Goldberg, A.P.1
Nowakowska, A.E.2
Antle, P.E.3
Snyder, L.R.4
-
47
-
-
85015349811
-
The effects of anionic ion-pairing reagents on the peptide retention in reversed-phase chromatography
-
CRC Press, Boca Raton, FL
-
Mant C.T., Hodges R.S. The effects of anionic ion-pairing reagents on the peptide retention in reversed-phase chromatography. High-performance Liquid Chromatography of Peptides and Proteins: Separation, Analysis and Conformation 1991, vols. 327-341. CRC Press, Boca Raton, FL.
-
(1991)
High-performance Liquid Chromatography of Peptides and Proteins: Separation, Analysis and Conformation
, vol.327-341
-
-
Mant, C.T.1
Hodges, R.S.2
-
48
-
-
0024854812
-
DryLab computer simulation for high-performance liquid chromatographic method development. II. Gradient elution
-
Dolan J.W., Lommen D.C., Snyder L.R. DryLab computer simulation for high-performance liquid chromatographic method development. II. Gradient elution. J. Chromatogr. 1989, 485:91-112.
-
(1989)
J. Chromatogr.
, vol.485
, pp. 91-112
-
-
Dolan, J.W.1
Lommen, D.C.2
Snyder, L.R.3
-
49
-
-
0002201039
-
Design of optimized high-performance liquid chromatographic gradients for the separation of either small or large molecules. II. Background and theory
-
Ghrist B.F.D., Snyder L.R. Design of optimized high-performance liquid chromatographic gradients for the separation of either small or large molecules. II. Background and theory. J. Chromatogr. 1988, 459:25-41.
-
(1988)
J. Chromatogr.
, vol.459
, pp. 25-41
-
-
Ghrist, B.F.D.1
Snyder, L.R.2
-
50
-
-
0013313272
-
Design of optimized high-performance liquid chromatographic gradients for the separation of either small or large molecules. Minimising errors in computer simulations
-
Ghrist B.F.D., Coopermann B.S., Snyder L.R. Design of optimized high-performance liquid chromatographic gradients for the separation of either small or large molecules. Minimising errors in computer simulations. J. Chromatogr. 1988, 459:1-23.
-
(1988)
J. Chromatogr.
, vol.459
, pp. 1-23
-
-
Ghrist, B.F.D.1
Coopermann, B.S.2
Snyder, L.R.3
-
51
-
-
79955482528
-
Performance evaluation of long monolithic silica capillary columns in gradient liquid chromatography using peptide mixtures
-
Eghbali H., Sandra K., Detobel F., Lynen F., Nakanishi K., Sandra P., Desmet G. Performance evaluation of long monolithic silica capillary columns in gradient liquid chromatography using peptide mixtures. J. Chromatogr. A 2011, 1218:3360-3366.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 3360-3366
-
-
Eghbali, H.1
Sandra, K.2
Detobel, F.3
Lynen, F.4
Nakanishi, K.5
Sandra, P.6
Desmet, G.7
-
52
-
-
77951207114
-
Parameters affecting the separation of intact proteins in gradient-elution reversed-phase chromatography using poly(styrene-co-divinylbenzene) monolithic capillary columns
-
Detobel F., Broeckhoven K., Wellens J., Wouters B., Swart R., Ursem M., Desmet G., Eeltink S. Parameters affecting the separation of intact proteins in gradient-elution reversed-phase chromatography using poly(styrene-co-divinylbenzene) monolithic capillary columns. J. Chromatogr. A 2010, 1217:3085-3090.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 3085-3090
-
-
Detobel, F.1
Broeckhoven, K.2
Wellens, J.3
Wouters, B.4
Swart, R.5
Ursem, M.6
Desmet, G.7
Eeltink, S.8
-
53
-
-
44749087402
-
Validation of a new reversed-phase high-performance liquid chromatography method for separation and quantification of bovine milk protein genetic variants
-
Bonfatti V., Grigoletto L., Cecchinato A., Gallo L., Carnier P. Validation of a new reversed-phase high-performance liquid chromatography method for separation and quantification of bovine milk protein genetic variants. J. Chromatogr. A 2008, 1195:101-106.
-
(2008)
J. Chromatogr. A
, vol.1195
, pp. 101-106
-
-
Bonfatti, V.1
Grigoletto, L.2
Cecchinato, A.3
Gallo, L.4
Carnier, P.5
-
54
-
-
72749097148
-
Selection of an analytical method for evaluating bovine serum albumin concentrations in pharmaceutical polymeric formulations
-
Umrethia M., Kett V.L., Andrews G.P., Malcolm R.K., Woolfson A.D. Selection of an analytical method for evaluating bovine serum albumin concentrations in pharmaceutical polymeric formulations. J. Pharm. Biomed. Anal. 2010, 51:1175-1179.
-
(2010)
J. Pharm. Biomed. Anal.
, vol.51
, pp. 1175-1179
-
-
Umrethia, M.1
Kett, V.L.2
Andrews, G.P.3
Malcolm, R.K.4
Woolfson, A.D.5
-
55
-
-
33751078051
-
Analysis of intact human follicle-stimulating hormone preparations by reversed-phase high-performance liquid chromatography
-
Loureiro R.F., Oliveira J.E., Torjesen P.A., Bartolini P., Ribela M.T.C.P. Analysis of intact human follicle-stimulating hormone preparations by reversed-phase high-performance liquid chromatography. J. Chromatogr. A 2006, 1136:10-18.
-
(2006)
J. Chromatogr. A
, vol.1136
, pp. 10-18
-
-
Loureiro, R.F.1
Oliveira, J.E.2
Torjesen, P.A.3
Bartolini, P.4
Ribela, M.T.C.P.5
-
56
-
-
77952322192
-
Analysis of human luteinizing hormone and human chorionic gonadotropin preparations of different origins by reversed-phase high-performance liquid chromatography
-
Almeida B.E., Oliveira J.E., Carvalho C.M., Dalmora S.L., Bartolini P., Ribela M.T.C.P. Analysis of human luteinizing hormone and human chorionic gonadotropin preparations of different origins by reversed-phase high-performance liquid chromatography. J. Pharm. Biomed. Anal. 2010, 53:90-97.
-
(2010)
J. Pharm. Biomed. Anal.
, vol.53
, pp. 90-97
-
-
Almeida, B.E.1
Oliveira, J.E.2
Carvalho, C.M.3
Dalmora, S.L.4
Bartolini, P.5
Ribela, M.T.C.P.6
-
57
-
-
33645243915
-
A simple and rapid HPLC method for quantitation of interferon-beta-2b in dosage forms and delivery systems
-
Zarrin A., Foroozesh M., Hamidi M., Samani S.M. A simple and rapid HPLC method for quantitation of interferon-beta-2b in dosage forms and delivery systems. J. Chromatogr. B 2006, 833:199-203.
-
(2006)
J. Chromatogr. B
, vol.833
, pp. 199-203
-
-
Zarrin, A.1
Foroozesh, M.2
Hamidi, M.3
Samani, S.M.4
-
58
-
-
20644441788
-
RP-HPLC determination of recombinant human interferon omega in the Pichia pastoris fermentation broth
-
Liu H., Pan H.C., Peng L., Cai S.X. RP-HPLC determination of recombinant human interferon omega in the Pichia pastoris fermentation broth. J. Pharm. Biomed. Anal. 2005, 38:734-737.
-
(2005)
J. Pharm. Biomed. Anal.
, vol.38
, pp. 734-737
-
-
Liu, H.1
Pan, H.C.2
Peng, L.3
Cai, S.X.4
-
59
-
-
0142124316
-
Rapid and sensitive method for simultaneous determination of insulin and A21-desamido insulin by high-performance liquid chromatography
-
Moslemi P., Najafabadi A.R., Tajerzadeh H. Rapid and sensitive method for simultaneous determination of insulin and A21-desamido insulin by high-performance liquid chromatography. J. Pharm. Biomed. Anal. 2003, 33:45-51.
-
(2003)
J. Pharm. Biomed. Anal.
, vol.33
, pp. 45-51
-
-
Moslemi, P.1
Najafabadi, A.R.2
Tajerzadeh, H.3
-
60
-
-
0342980845
-
Validated HPLC method for determination of PAT-5A, an insulin sensitizing agent, in rat plasma
-
Mamidi N.V.S.R., Kumar V.V.S.S., Katneni K., Chaluvadi M.R., Shreeram S., Gangadhar S., Nataraj B., Kishore P.H., Bhushan V., Subramaniam S. Validated HPLC method for determination of PAT-5A, an insulin sensitizing agent, in rat plasma. J. Pharm. Biomed. Anal. 2000, 22:251-255.
-
(2000)
J. Pharm. Biomed. Anal.
, vol.22
, pp. 251-255
-
-
Mamidi, N.V.S.R.1
Kumar, V.V.S.S.2
Katneni, K.3
Chaluvadi, M.R.4
Shreeram, S.5
Gangadhar, S.6
Nataraj, B.7
Kishore, P.H.8
Bhushan, V.9
Subramaniam, S.10
-
61
-
-
0024245270
-
Oxidation of rat insulin II, but not I, leads to anomalous elution profiles upon HPLC analysis of insulin-related peptides
-
Gross D., Skvorak A., Hendrick G., Weir G., Komaroff L.V., Halban P. Oxidation of rat insulin II, but not I, leads to anomalous elution profiles upon HPLC analysis of insulin-related peptides. FEBS Lett. 1988, 241:205-208.
-
(1988)
FEBS Lett.
, vol.241
, pp. 205-208
-
-
Gross, D.1
Skvorak, A.2
Hendrick, G.3
Weir, G.4
Komaroff, L.V.5
Halban, P.6
-
62
-
-
0032827058
-
Separation of oxidized and deamidated human growth hormone variants by isocratic reversed-phase high-performance liquid chromatography
-
Karlsson G., Gellerfors P., Persson A., Norén B., Edlund P.O., Sandberg C., Birnbaum S. Separation of oxidized and deamidated human growth hormone variants by isocratic reversed-phase high-performance liquid chromatography. J. Chromatogr. A 1999, 855:147-155.
-
(1999)
J. Chromatogr. A
, vol.855
, pp. 147-155
-
-
Karlsson, G.1
Gellerfors, P.2
Persson, A.3
Norén, B.4
Edlund, P.O.5
Sandberg, C.6
Birnbaum, S.7
-
64
-
-
0037437687
-
Quantification of the isomerization of Asp residue in recombinant human alpha-A-crystallin by reversed-phase HPLC
-
Sadakane Y., Yamazaki T., Nakagomi K., Akizawa T., Fujii N., Tanimura T., Kaneda M., Hatanaka Y. Quantification of the isomerization of Asp residue in recombinant human alpha-A-crystallin by reversed-phase HPLC. J. Pharm. Biomed. Anal. 2003, 30:1825-1833.
-
(2003)
J. Pharm. Biomed. Anal.
, vol.30
, pp. 1825-1833
-
-
Sadakane, Y.1
Yamazaki, T.2
Nakagomi, K.3
Akizawa, T.4
Fujii, N.5
Tanimura, T.6
Kaneda, M.7
Hatanaka, Y.8
-
65
-
-
35048904689
-
Perfusion reversed-phase high-performance liquid chromatography/mass spectrometry analysis of intact soybean proteins for the characterization of soybean cultivars
-
Rubio F.C., Marina M.L., Garcia C. Perfusion reversed-phase high-performance liquid chromatography/mass spectrometry analysis of intact soybean proteins for the characterization of soybean cultivars. J. Chromatogr. A 2007, 1170:34-43.
-
(2007)
J. Chromatogr. A
, vol.1170
, pp. 34-43
-
-
Rubio, F.C.1
Marina, M.L.2
Garcia, C.3
-
66
-
-
58149105278
-
Sense and non-sense of high-temperature liquid chromatography
-
Heinisch S., Rocca J.-L. Sense and non-sense of high-temperature liquid chromatography. J. Chromatogr. A 2009, 1216:642-658.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 642-658
-
-
Heinisch, S.1
Rocca, J.-L.2
-
67
-
-
33748435941
-
Elevated temperature and temperature programming in conventional liquid chromatography-fundamentals and applications
-
Vanhoenacker G., Sandra P. Elevated temperature and temperature programming in conventional liquid chromatography-fundamentals and applications. J. Sep. Sci. 2006, 29:1822-1835.
-
(2006)
J. Sep. Sci.
, vol.29
, pp. 1822-1835
-
-
Vanhoenacker, G.1
Sandra, P.2
-
68
-
-
33645677969
-
Detection modes with high temperature liquid chromatography: a review
-
Guillarme D., Heinisch S. Detection modes with high temperature liquid chromatography: a review. Sep. Purif. Rev. 2005, 34:181-216.
-
(2005)
Sep. Purif. Rev.
, vol.34
, pp. 181-216
-
-
Guillarme, D.1
Heinisch, S.2
-
69
-
-
4744367342
-
Effect of temperature in reversed phase liquid chromatography
-
Guillarme D., Heinisch S., Rocca J.L. Effect of temperature in reversed phase liquid chromatography. J. Chromatogr. A 2004, 1052:39-51.
-
(2004)
J. Chromatogr. A
, vol.1052
, pp. 39-51
-
-
Guillarme, D.1
Heinisch, S.2
Rocca, J.L.3
-
70
-
-
77953476888
-
New trends in fast and high resolution liquid chromatography: a critical comparison of existing approaches
-
Guillarme D., Ruta J., Rudaz S., Veuthey J.L. New trends in fast and high resolution liquid chromatography: a critical comparison of existing approaches. Anal. Bioanal. Chem. 2010, 397:1069-1082.
-
(2010)
Anal. Bioanal. Chem.
, vol.397
, pp. 1069-1082
-
-
Guillarme, D.1
Ruta, J.2
Rudaz, S.3
Veuthey, J.L.4
-
71
-
-
77955900006
-
Comparison of columns packed with porous sub-2μm and superficially porous sub-3μm particles for peptides analysis at ambient and high temperature
-
Ruta J., Guillarme D., Rudaz S., Veuthey J.L. Comparison of columns packed with porous sub-2μm and superficially porous sub-3μm particles for peptides analysis at ambient and high temperature. J. Sep. Sci. 2010, 33:2465-2477.
-
(2010)
J. Sep. Sci.
, vol.33
, pp. 2465-2477
-
-
Ruta, J.1
Guillarme, D.2
Rudaz, S.3
Veuthey, J.L.4
-
72
-
-
0029020358
-
High speed high-performance liquid chromatography of peptides and proteins
-
Chen H., Cs Horváth High speed high-performance liquid chromatography of peptides and proteins. J. Chromatogr. A 1995, 705:3-20.
-
(1995)
J. Chromatogr. A
, vol.705
, pp. 3-20
-
-
Chen, H.1
Horváth, C.2
-
73
-
-
36248998335
-
Chromatographic performance of silica-based stationary phases in high temperature liquid chromatography: pharmaceutical applications
-
Guillarme D., Russo R., Rudaz S., Bicchi C., Veuthey J.L. Chromatographic performance of silica-based stationary phases in high temperature liquid chromatography: pharmaceutical applications. Curr. Pharm. Anal. 2007, 4:221-229.
-
(2007)
Curr. Pharm. Anal.
, vol.4
, pp. 221-229
-
-
Guillarme, D.1
Russo, R.2
Rudaz, S.3
Bicchi, C.4
Veuthey, J.L.5
-
74
-
-
67649385775
-
Metabolite profiling of plant extracts by high temperature UHPLC-TOF/MS
-
Grata E., Guillarme D., Glauser G., Boccard J., Carrupt P.A., Veuthey J.L., Rudaz S., Wolfender J.L. Metabolite profiling of plant extracts by high temperature UHPLC-TOF/MS. J. Chromatogr. A 2009, 1216:5660-5668.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 5660-5668
-
-
Grata, E.1
Guillarme, D.2
Glauser, G.3
Boccard, J.4
Carrupt, P.A.5
Veuthey, J.L.6
Rudaz, S.7
Wolfender, J.L.8
-
75
-
-
33646929252
-
Effect of temperature on the retention of ionizable compounds in reversed-phase liquid chromatography: application to method development
-
Heinisch S., Puy G., Barrioulet M.P., Rocca J.L. Effect of temperature on the retention of ionizable compounds in reversed-phase liquid chromatography: application to method development. J. Chromatogr. A 2006, 1118:234-243.
-
(2006)
J. Chromatogr. A
, vol.1118
, pp. 234-243
-
-
Heinisch, S.1
Puy, G.2
Barrioulet, M.P.3
Rocca, J.L.4
-
76
-
-
82955162687
-
Analysis of peptides and proteins using UHPLC and fused core technologies
-
Staub A., Zurlino D., Rudaz S., Veuthey J.L., Guillarme D. Analysis of peptides and proteins using UHPLC and fused core technologies. J. Chromatogr. A 2011, 1218:8903-8914.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 8903-8914
-
-
Staub, A.1
Zurlino, D.2
Rudaz, S.3
Veuthey, J.L.4
Guillarme, D.5
-
77
-
-
33646007704
-
Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase
-
Teutenberg T., Goetze H.J., Tuerk J., Ploeger J., Kiffmeyer T.K., Schmidt K.G., Kohorst W.G., Rohe T., Jansen H.D., Weber H. Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase. J. Chromatogr. A 2006, 1114:89-96.
-
(2006)
J. Chromatogr. A
, vol.1114
, pp. 89-96
-
-
Teutenberg, T.1
Goetze, H.J.2
Tuerk, J.3
Ploeger, J.4
Kiffmeyer, T.K.5
Schmidt, K.G.6
Kohorst, W.G.7
Rohe, T.8
Jansen, H.D.9
Weber, H.10
-
78
-
-
67649982742
-
Temperature and pH-stability of commercial stationary phases
-
Teutenberg T., Hollebekkers K., Wiese S., Boergers A. Temperature and pH-stability of commercial stationary phases. J. Sep. Sci. 2009, 32:1262-1274.
-
(2009)
J. Sep. Sci.
, vol.32
, pp. 1262-1274
-
-
Teutenberg, T.1
Hollebekkers, K.2
Wiese, S.3
Boergers, A.4
-
79
-
-
34548501736
-
High throughput liquid chromatography with sub-2μm particles at very high pressure and high temperature
-
Nguyen D.T.T., Guillarme D., Heinisch S., Barrioulet M.P., Rocca J.L., Rudaz S., Veuthey J.L. High throughput liquid chromatography with sub-2μm particles at very high pressure and high temperature. J. Chromatogr. A 2007, 1167:76-84.
-
(2007)
J. Chromatogr. A
, vol.1167
, pp. 76-84
-
-
Nguyen, D.T.T.1
Guillarme, D.2
Heinisch, S.3
Barrioulet, M.P.4
Rocca, J.L.5
Rudaz, S.6
Veuthey, J.L.7
-
80
-
-
20444481662
-
High temperature fast chromatography of proteins using a silica-based stationary phase with greatly enhanced low pH stability
-
Yang X., Ma L., Carr P.W. High temperature fast chromatography of proteins using a silica-based stationary phase with greatly enhanced low pH stability. J. Chromatogr. A 2005, 1079:213-220.
-
(2005)
J. Chromatogr. A
, vol.1079
, pp. 213-220
-
-
Yang, X.1
Ma, L.2
Carr, P.W.3
-
81
-
-
0036500211
-
A study of the critical criteria for analyte stability in high-temperature liquid chromatography
-
Thompson J.D., Carr P.W. A study of the critical criteria for analyte stability in high-temperature liquid chromatography. Anal. Chem. 2002, 74:1017-1023.
-
(2002)
Anal. Chem.
, vol.74
, pp. 1017-1023
-
-
Thompson, J.D.1
Carr, P.W.2
-
82
-
-
0003943011
-
-
Wiley, New York, (Chapter 2)
-
Yau W.W., Kirkland J.J., Bly D.D. Modern Size-Exclusion Liquid Chromatography 1979, Wiley, New York, (Chapter 2).
-
(1979)
Modern Size-Exclusion Liquid Chromatography
-
-
Yau, W.W.1
Kirkland, J.J.2
Bly, D.D.3
-
83
-
-
0014144236
-
Fast liquid chromatography: an investigation of operating parameters and the separation of nucleotides on pellicular ion exchangers
-
Horvath C., Preiss B.A., Lipsky S.R. Fast liquid chromatography: an investigation of operating parameters and the separation of nucleotides on pellicular ion exchangers. Anal. Chem. 1967, 39:1422-1428.
-
(1967)
Anal. Chem.
, vol.39
, pp. 1422-1428
-
-
Horvath, C.1
Preiss, B.A.2
Lipsky, S.R.3
-
84
-
-
84963072104
-
Column design in high pressure liquid chromatography
-
Horvath C., Lipsky S.R. Column design in high pressure liquid chromatography. J. Chromatogr. Sci. 1969, 7:109-116.
-
(1969)
J. Chromatogr. Sci.
, vol.7
, pp. 109-116
-
-
Horvath, C.1
Lipsky, S.R.2
-
85
-
-
0008888194
-
Controlled surface porosity supports for high speed gas and liquid chromatography
-
Kirkland J.J. Controlled surface porosity supports for high speed gas and liquid chromatography. Anal. Chem. 1969, 41:218-220.
-
(1969)
Anal. Chem.
, vol.41
, pp. 218-220
-
-
Kirkland, J.J.1
-
86
-
-
79952817768
-
Shell particles, trials, tribulations and triumphs
-
Guiochon G., Gritti F. Shell particles, trials, tribulations and triumphs. J. Chromatogr. A 2011, 1218:1915-1938.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 1915-1938
-
-
Guiochon, G.1
Gritti, F.2
-
87
-
-
0034683107
-
Superficially porous silica microspheres for fast high-performance liquid chromatography of macromolecules
-
Kirkland J.J., Truszkowski F.A., Dilks C.H., Engel G.S. Superficially porous silica microspheres for fast high-performance liquid chromatography of macromolecules. J. Chromatogr. A 2000, 890:3-13.
-
(2000)
J. Chromatogr. A
, vol.890
, pp. 3-13
-
-
Kirkland, J.J.1
Truszkowski, F.A.2
Dilks, C.H.3
Engel, G.S.4
-
88
-
-
58249143554
-
Shell and small particles: evaluation of new column technology
-
Fekete S., Fekete J., Ganzler K. Shell and small particles: evaluation of new column technology. J. Pharm. Biomed. Anal. 2009, 49:64-71.
-
(2009)
J. Pharm. Biomed. Anal.
, vol.49
, pp. 64-71
-
-
Fekete, S.1
Fekete, J.2
Ganzler, K.3
-
89
-
-
78751701553
-
The mass transfer kinetics in columns packed with Halo-ES shell particles
-
Gritti F., Guiochon G. The mass transfer kinetics in columns packed with Halo-ES shell particles. J. Chromatogr. A 2011, 1218:907-921.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 907-921
-
-
Gritti, F.1
Guiochon, G.2
-
90
-
-
77952672825
-
Comparative study of new shell-type, sub-2μm fully porous and monolith stationary phases, focusing on mass-transfer resistance
-
Olah E., Fekete S., Fekete J., Ganzler K. Comparative study of new shell-type, sub-2μm fully porous and monolith stationary phases, focusing on mass-transfer resistance. J. Chromatogr. A 2010, 1217:3642-3653.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 3642-3653
-
-
Olah, E.1
Fekete, S.2
Fekete, J.3
Ganzler, K.4
-
91
-
-
79952179851
-
Structural variation of solid core and thickness of porous shell of 1.7μm core-shell silica particles on chromatographic performance: narrow bore columns
-
Omamogho J.O., Hanrahan J.P., Tobin J., Glennon J.D. Structural variation of solid core and thickness of porous shell of 1.7μm core-shell silica particles on chromatographic performance: narrow bore columns. J. Chromatogr. A 2011, 1218:1942-1953.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 1942-1953
-
-
Omamogho, J.O.1
Hanrahan, J.P.2
Tobin, J.3
Glennon, J.D.4
-
92
-
-
77955743161
-
Wider pore superficially porous particles for peptide separations by HPLC
-
Schuster S.A., Wagner B.M., Boyes B.E., Kirkland J.J. Wider pore superficially porous particles for peptide separations by HPLC. J. Chromatogr. Sci. 2010, 48:566-571.
-
(2010)
J. Chromatogr. Sci.
, vol.48
, pp. 566-571
-
-
Schuster, S.A.1
Wagner, B.M.2
Boyes, B.E.3
Kirkland, J.J.4
-
93
-
-
84857062754
-
Fast high performance liquid chromatography separations for proteomic applications using Fused-Core® silica particles
-
Schuster S.A., Boyes B.E., Wagner B.M., Kirkland J.J. Fast high performance liquid chromatography separations for proteomic applications using Fused-Core® silica particles. J. Chromatogr. A 2012, 1228:232-241.
-
(2012)
J. Chromatogr. A
, vol.1228
, pp. 232-241
-
-
Schuster, S.A.1
Boyes, B.E.2
Wagner, B.M.3
Kirkland, J.J.4
-
94
-
-
84859268779
-
Evaluation of a new wide pore core-shell material (Aeris™ WIDEPORE) and comparison with other existing stationary PHASES FOR THE analysis of intact proteins
-
doi:10.1016/j.chroma.2012.03.018
-
S. Fekete, R. Berky, J. Fekete, J.L. Veuthey, D. Guillarme, Evaluation of a new wide pore core-shell material (Aeris™ WIDEPORE) and comparison with other existing stationary PHASES FOR THE analysis of intact proteins, J. Chromatogr. A, (2012) doi:10.1016/j.chroma.2012.03.018.
-
(2012)
J. Chromatogr. A
-
-
Fekete, S.1
Berky, R.2
Fekete, J.3
Veuthey, J.L.4
Guillarme, D.5
-
95
-
-
0001349741
-
Monolithic, molded, porous materials with high flow characteristics for separations, catalysis, or solid-phase chemistry: control of porous properties during polymerization
-
Viklund C., Svec F., Fréchet J.M.J., Irgum K. Monolithic, molded, porous materials with high flow characteristics for separations, catalysis, or solid-phase chemistry: control of porous properties during polymerization. Chem. Mater. 1996, 8:744-750.
-
(1996)
Chem. Mater.
, vol.8
, pp. 744-750
-
-
Viklund, C.1
Svec, F.2
Fréchet, J.M.J.3
Irgum, K.4
-
96
-
-
70349823142
-
Influence of the polymerisation time on the porous and chromatographic properties of monolithic poly(1,2-bis(p-vinylphenyl))ethane capillary columns
-
Greider A., Trojer L., Huck C.W., Bonn G.K. Influence of the polymerisation time on the porous and chromatographic properties of monolithic poly(1,2-bis(p-vinylphenyl))ethane capillary columns. J. Chromatogr. A 2009, 1216:7747-7754.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 7747-7754
-
-
Greider, A.1
Trojer, L.2
Huck, C.W.3
Bonn, G.K.4
-
97
-
-
45649085109
-
Monolithic porous polymer stationary phases in polyimide chips for the fast high-performance liquid chromatography separation of proteins and peptides
-
Levkin P.A., Eeltink S., Stratton T.R., Brennen R., Robotti K., Yin H., Killeen K., Svec F., Fréchet J.M.J. Monolithic porous polymer stationary phases in polyimide chips for the fast high-performance liquid chromatography separation of proteins and peptides. J. Chromatogr. A 2008, 1200:55-61.
-
(2008)
J. Chromatogr. A
, vol.1200
, pp. 55-61
-
-
Levkin, P.A.1
Eeltink, S.2
Stratton, T.R.3
Brennen, R.4
Robotti, K.5
Yin, H.6
Killeen, K.7
Svec, F.8
Fréchet, J.M.J.9
-
98
-
-
70649088957
-
Poly[hydroxyethyl crylate-co-poly(ethylene glycol) diacrylate] monolithic column for efficient hydrophobic interaction chromatography of proteins
-
Li Y.Y., Tolley H.D., Lee M.L. Poly[hydroxyethyl crylate-co-poly(ethylene glycol) diacrylate] monolithic column for efficient hydrophobic interaction chromatography of proteins. Anal. Chem. 2009, 81:9416-9424.
-
(2009)
Anal. Chem.
, vol.81
, pp. 9416-9424
-
-
Li, Y.Y.1
Tolley, H.D.2
Lee, M.L.3
-
99
-
-
70350493751
-
Accurate molecular weight analysis of histones using FFE and RP-HPLC on monolithic capillary columns
-
Sneekes E.J., Hun J., Elliot M., Ausio J., Borchers C. Accurate molecular weight analysis of histones using FFE and RP-HPLC on monolithic capillary columns. J. Sep. Sci. 2009, 32:2691-2698.
-
(2009)
J. Sep. Sci.
, vol.32
, pp. 2691-2698
-
-
Sneekes, E.J.1
Hun, J.2
Elliot, M.3
Ausio, J.4
Borchers, C.5
-
100
-
-
12244264434
-
Analysis of biological and synthetic ribonucleic acids by liquid chromatography-mass spectrometry using monolithic capillary columns
-
Holzl G., Oberacher H., Pitsch S., Stutz A., Huber C.G. Analysis of biological and synthetic ribonucleic acids by liquid chromatography-mass spectrometry using monolithic capillary columns. Anal. Chem. 2005, 77:673-680.
-
(2005)
Anal. Chem.
, vol.77
, pp. 673-680
-
-
Holzl, G.1
Oberacher, H.2
Pitsch, S.3
Stutz, A.4
Huber, C.G.5
-
101
-
-
1642462839
-
Applicability of tandem mass spectrometry to the automated sequencing of long-chain oligonucleotides
-
Oberacher H., Parson W., Oefner P.J., Mayr B.M., Huber C.G. Applicability of tandem mass spectrometry to the automated sequencing of long-chain oligonucleotides. J. Am. Soc. Mass Spectrom. 2004, 15:510-522.
-
(2004)
J. Am. Soc. Mass Spectrom.
, vol.15
, pp. 510-522
-
-
Oberacher, H.1
Parson, W.2
Oefner, P.J.3
Mayr, B.M.4
Huber, C.G.5
-
102
-
-
0142072517
-
Low Attomole ESI-MS/MS analysis of tryptic peptides using 20-μm I.D. monolithic capillary columns
-
Ivanov A.R., Zang L., Karger B.L. Low Attomole ESI-MS/MS analysis of tryptic peptides using 20-μm I.D. monolithic capillary columns. Anal. Chem. 2003, 75:5306-5316.
-
(2003)
Anal. Chem.
, vol.75
, pp. 5306-5316
-
-
Ivanov, A.R.1
Zang, L.2
Karger, B.L.3
-
103
-
-
36949032551
-
Optimization of the porous structure and polarity of polymethacrylate-based monolithic capillary columns for the LC-MS separation of enzymatic digests
-
Eeltink S., Geiser L., Svec F., Fréchet J.M.J. Optimization of the porous structure and polarity of polymethacrylate-based monolithic capillary columns for the LC-MS separation of enzymatic digests. J. Sep. Sci. 2007, 30:2814-2820.
-
(2007)
J. Sep. Sci.
, vol.30
, pp. 2814-2820
-
-
Eeltink, S.1
Geiser, L.2
Svec, F.3
Fréchet, J.M.J.4
-
104
-
-
77957287523
-
High-efficiency liquid chromatography-mass spectrometry separations with 50mm, 250mm, and 1m long polymer-based monolithic capillary columns for the characterization of complex proteolytic digests
-
Eeltink S., Dolman S., Swart R., Ursem M., Schoenmakers P.J. High-efficiency liquid chromatography-mass spectrometry separations with 50mm, 250mm, and 1m long polymer-based monolithic capillary columns for the characterization of complex proteolytic digests. J. Chromatogr. A 2010, 1217:6610-6615.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 6610-6615
-
-
Eeltink, S.1
Dolman, S.2
Swart, R.3
Ursem, M.4
Schoenmakers, P.J.5
-
105
-
-
0030583845
-
Molded monolithic rod of macroporous poly(styrene-co-divinylbenzene) as a separation medium for HPLC of synthetic polymers: on-column precipitation-redissolution chromatography as an alternative to size exclusion chromatography of styrene oligomers and polymers
-
Petro M., Svec F., Gitsov I., Fréchet J.M.J. Molded monolithic rod of macroporous poly(styrene-co-divinylbenzene) as a separation medium for HPLC of synthetic polymers: on-column precipitation-redissolution chromatography as an alternative to size exclusion chromatography of styrene oligomers and polymers. Anal. Chem. 1996, 68:315-321.
-
(1996)
Anal. Chem.
, vol.68
, pp. 315-321
-
-
Petro, M.1
Svec, F.2
Gitsov, I.3
Fréchet, J.M.J.4
-
106
-
-
76849109997
-
Size-sorting combined with improved nanocapillary-LC-MS for identification of intact proteins up to 80kDa
-
Vellaichamy A., Tran J.C., Catherman A.D., Lee J.E., Kellie J.F., Sweet S.M.M., Zamdborg L., Thomas P.M., Ahlf D.R., Durbin K.R., Valaskovic G., Kelleher N.L. Size-sorting combined with improved nanocapillary-LC-MS for identification of intact proteins up to 80kDa. Anal. Chem. 2010, 82:1234-1244.
-
(2010)
Anal. Chem.
, vol.82
, pp. 1234-1244
-
-
Vellaichamy, A.1
Tran, J.C.2
Catherman, A.D.3
Lee, J.E.4
Kellie, J.F.5
Sweet, S.M.M.6
Zamdborg, L.7
Thomas, P.M.8
Ahlf, D.R.9
Durbin, K.R.10
Valaskovic, G.11
Kelleher, N.L.12
-
107
-
-
0001047872
-
Gel permeation chromatography on porous poly(ethylene glycol methacrylate)
-
Kubin M., Spacek P., Chromecek R. Gel permeation chromatography on porous poly(ethylene glycol methacrylate). Collect. Czech. Chem. Commun. 1967, 32:3881-3887.
-
(1967)
Collect. Czech. Chem. Commun.
, vol.32
, pp. 3881-3887
-
-
Kubin, M.1
Spacek, P.2
Chromecek, R.3
-
108
-
-
0000259172
-
Highly permeable open-pore polyurethane columns for liquid chromatography
-
Hansen L.C., Sievers R.E. Highly permeable open-pore polyurethane columns for liquid chromatography. J. Chromatogr. 1974, 99:123-133.
-
(1974)
J. Chromatogr.
, vol.99
, pp. 123-133
-
-
Hansen, L.C.1
Sievers, R.E.2
-
109
-
-
0000651036
-
High performance liquid chromatography on continuous polymer beds
-
Hjerten S., Liao J.L., Zhang R. High performance liquid chromatography on continuous polymer beds. J. Chromatogr. 1989, 473:273-275.
-
(1989)
J. Chromatogr.
, vol.473
, pp. 273-275
-
-
Hjerten, S.1
Liao, J.L.2
Zhang, R.3
-
110
-
-
84859338859
-
Continuous rods of macroporous polymer as high performance liquid chromatographic media
-
Svec F., Frechet J.M.J. Continuous rods of macroporous polymer as high performance liquid chromatographic media. Anal. Chem. 1992, 64:820-822.
-
(1992)
Anal. Chem.
, vol.64
, pp. 820-822
-
-
Svec, F.1
Frechet, J.M.J.2
-
111
-
-
0027668888
-
Rod of macroporous polymeric stationary phase as continuous separation medium for reversed phase chromatography
-
Wang Q.C., Svec F., Frechet J.M.J. Rod of macroporous polymeric stationary phase as continuous separation medium for reversed phase chromatography. Anal. Chem. 1993, 65:2243-2248.
-
(1993)
Anal. Chem.
, vol.65
, pp. 2243-2248
-
-
Wang, Q.C.1
Svec, F.2
Frechet, J.M.J.3
-
112
-
-
0032883213
-
Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography
-
Gusev I., Huang X., Horvath C. Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography. J. Chromatogr. A 1999, 855:273-290.
-
(1999)
J. Chromatogr. A
, vol.855
, pp. 273-290
-
-
Gusev, I.1
Huang, X.2
Horvath, C.3
-
113
-
-
0030298087
-
Molded continuous poly(styrene-co-divinylbenzene) rod as a separation medium for the very fast separations of polymers: a comparison of the chromatographic properties of the monolithic rod with columns packed with porous and non-porous beads in precipitation-redissolution chromatography of polystyrenes
-
Petro M., Svec F., Frechet J.M.J. Molded continuous poly(styrene-co-divinylbenzene) rod as a separation medium for the very fast separations of polymers: a comparison of the chromatographic properties of the monolithic rod with columns packed with porous and non-porous beads in precipitation-redissolution chromatography of polystyrenes. J. Chromatogr. A 1996, 752:59-66.
-
(1996)
J. Chromatogr. A
, vol.752
, pp. 59-66
-
-
Petro, M.1
Svec, F.2
Frechet, J.M.J.3
-
114
-
-
0034665944
-
High performance liquid chromatography-electrospray ionization mass spectrometry of single and double stranded nucleic acids using monolithic capillary columns
-
Premstaller A., Oberacher H., Huber C.G. High performance liquid chromatography-electrospray ionization mass spectrometry of single and double stranded nucleic acids using monolithic capillary columns. Anal. Chem. 2000, 72:4386-4393.
-
(2000)
Anal. Chem.
, vol.72
, pp. 4386-4393
-
-
Premstaller, A.1
Oberacher, H.2
Huber, C.G.3
-
115
-
-
1242292440
-
Characterization of some physical and chromatographic properties of monolithic poly-(styrene-co-divinylbenzene) columns
-
Oberacher H., Premstaller A., Huber C.G. Characterization of some physical and chromatographic properties of monolithic poly-(styrene-co-divinylbenzene) columns. J. Chromatogr. A 2004, 1030:201-208.
-
(2004)
J. Chromatogr. A
, vol.1030
, pp. 201-208
-
-
Oberacher, H.1
Premstaller, A.2
Huber, C.G.3
-
116
-
-
0037354352
-
Methacrylate monoliths prepared from various hydrophobic and hydrophilic monomers-structural and chromatographic characteristics
-
Merhar M., Podgornik A., Barut M., Zigon M., Strancar A. Methacrylate monoliths prepared from various hydrophobic and hydrophilic monomers-structural and chromatographic characteristics. J. Sep. Sci. 2003, 26:322-330.
-
(2003)
J. Sep. Sci.
, vol.26
, pp. 322-330
-
-
Merhar, M.1
Podgornik, A.2
Barut, M.3
Zigon, M.4
Strancar, A.5
-
117
-
-
4344647040
-
Preparation and HPLC applications of rigid macroporous organic polymer monoliths
-
Svec F. Preparation and HPLC applications of rigid macroporous organic polymer monoliths. J. Sep. Sci. 2004, 27:747-766.
-
(2004)
J. Sep. Sci.
, vol.27
, pp. 747-766
-
-
Svec, F.1
-
118
-
-
4644351831
-
Photopolymerized monolithic capillary columns for rapid HPLC separation of proteins
-
Lee D., Svec F., Frechet J.M.J. Photopolymerized monolithic capillary columns for rapid HPLC separation of proteins. J. Chromatogr. A 2004, 1051:53-60.
-
(2004)
J. Chromatogr. A
, vol.1051
, pp. 53-60
-
-
Lee, D.1
Svec, F.2
Frechet, J.M.J.3
-
119
-
-
0000841410
-
A new class of continuous polymer supports prepared by ring-opening metathesis polymerization: a straightforward route to functionalized monoliths
-
Sinner F., Buchmeiser M.R. A new class of continuous polymer supports prepared by ring-opening metathesis polymerization: a straightforward route to functionalized monoliths. Macromolecules 2000, 33:5777-5786.
-
(2000)
Macromolecules
, vol.33
, pp. 5777-5786
-
-
Sinner, F.1
Buchmeiser, M.R.2
-
120
-
-
60649088702
-
High temperature liquid chromatography with monolithic capillary columns and pure water eluent
-
Causon T.J., Shellie R.A., Hilder E.F. High temperature liquid chromatography with monolithic capillary columns and pure water eluent. Analyst 2009, 134:440-442.
-
(2009)
Analyst
, vol.134
, pp. 440-442
-
-
Causon, T.J.1
Shellie, R.A.2
Hilder, E.F.3
-
121
-
-
70350502142
-
1mm ID poly(styrene-co-divinylbenzene) monolithic columns for high-peak capacity one- and two-dimensional liquid chromatographic separations of intact proteins
-
Eeltink S., Dolman S., Detobel F., Desmet G., Swart R., Ursem M. 1mm ID poly(styrene-co-divinylbenzene) monolithic columns for high-peak capacity one- and two-dimensional liquid chromatographic separations of intact proteins. J. Sep. Sci. 2009, 32:2504-2509.
-
(2009)
J. Sep. Sci.
, vol.32
, pp. 2504-2509
-
-
Eeltink, S.1
Dolman, S.2
Detobel, F.3
Desmet, G.4
Swart, R.5
Ursem, M.6
-
122
-
-
78649423856
-
High-efficiency nano- and micro-HPLC-high-resolution Orbitrap-MS platform for top-down proteomics
-
Mohr J., Swart R., Samonig M., Bohm G., Huber C.G. High-efficiency nano- and micro-HPLC-high-resolution Orbitrap-MS platform for top-down proteomics. Proteomics 2010, 10:3598-3609.
-
(2010)
Proteomics
, vol.10
, pp. 3598-3609
-
-
Mohr, J.1
Swart, R.2
Samonig, M.3
Bohm, G.4
Huber, C.G.5
-
123
-
-
33646263581
-
Monolithic poly(p-methylstyrene-co-1,2-bis(p-vinylphenyl)ethane) capillary columns as novel styrene stationary phases for biopolymer separation
-
Trojer L., Lubbad S.H., Bisjak C.P., Bonn G.K. Monolithic poly(p-methylstyrene-co-1,2-bis(p-vinylphenyl)ethane) capillary columns as novel styrene stationary phases for biopolymer separation. J. Chromatogr. A 2006, 1117:56-66.
-
(2006)
J. Chromatogr. A
, vol.1117
, pp. 56-66
-
-
Trojer, L.1
Lubbad, S.H.2
Bisjak, C.P.3
Bonn, G.K.4
-
124
-
-
12144283108
-
Recent advances in capillary separations for proteomics
-
Cooper J.W., Wang Y., Lee C.S. Recent advances in capillary separations for proteomics. Electrophoresis 2004, 25:3913-3926.
-
(2004)
Electrophoresis
, vol.25
, pp. 3913-3926
-
-
Cooper, J.W.1
Wang, Y.2
Lee, C.S.3
-
125
-
-
9144242449
-
Microfluidic systems in proteomics
-
Lion N., Rohner T.C., Dayon L., Arnaud I.L., Damoc E., Youhnovski N., Wu Z., Roussel C., Josserand J., Jensen H., Rossier J.S., Przybylski M., Girault H.H. Microfluidic systems in proteomics. Electrophoresis 2003, 24:3533-3562.
-
(2003)
Electrophoresis
, vol.24
, pp. 3533-3562
-
-
Lion, N.1
Rohner, T.C.2
Dayon, L.3
Arnaud, I.L.4
Damoc, E.5
Youhnovski, N.6
Wu, Z.7
Roussel, C.8
Josserand, J.9
Jensen, H.10
Rossier, J.S.11
Przybylski, M.12
Girault, H.H.13
-
126
-
-
33750349153
-
Usefulness of an integrated microfluidic device (HPLC-Chip-MS) to enhance confidence in protein identification by proteomics
-
Hardouin J., Duchateau M., Joubert-Caron R., Caron M. Usefulness of an integrated microfluidic device (HPLC-Chip-MS) to enhance confidence in protein identification by proteomics. Rapid Commun. Mass Spectrom. 2006, 20:3236-3244.
-
(2006)
Rapid Commun. Mass Spectrom.
, vol.20
, pp. 3236-3244
-
-
Hardouin, J.1
Duchateau, M.2
Joubert-Caron, R.3
Caron, M.4
-
127
-
-
0035984039
-
Poly(dimethylsiloxane) as a material for fabricating microfluidic devices
-
McDonald J.C., Whitesides G.M. Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. Acc. Chem. Res. 2002, 35:491-499.
-
(2002)
Acc. Chem. Res.
, vol.35
, pp. 491-499
-
-
McDonald, J.C.1
Whitesides, G.M.2
-
128
-
-
0036123034
-
Towards disposable lab-on-a-chip: poly(methylmethacrylate) microchip electrophoresis device with electrochemical detection
-
Wang J., Pumera M., Chatrathi M.P., Escarpa A., Konrad R., Griebel A., Doerner W., Loewe H. Towards disposable lab-on-a-chip: poly(methylmethacrylate) microchip electrophoresis device with electrochemical detection. Electrophoresis 2002, 23:596-601.
-
(2002)
Electrophoresis
, vol.23
, pp. 596-601
-
-
Wang, J.1
Pumera, M.2
Chatrathi, M.P.3
Escarpa, A.4
Konrad, R.5
Griebel, A.6
Doerner, W.7
Loewe, H.8
-
129
-
-
0347134477
-
Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
-
Sia S.K., Whitesides G.M. Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies. Electrophoresis 2003, 24:3563-3576.
-
(2003)
Electrophoresis
, vol.24
, pp. 3563-3576
-
-
Sia, S.K.1
Whitesides, G.M.2
-
131
-
-
12244255362
-
Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip
-
Yin H., Killeen K., Brennen R., Sobek D., Werlich M., Van de Goor T. Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip. Anal. Chem. 2005, 77:527-533.
-
(2005)
Anal. Chem.
, vol.77
, pp. 527-533
-
-
Yin, H.1
Killeen, K.2
Brennen, R.3
Sobek, D.4
Werlich, M.5
Van de Goor, T.6
-
132
-
-
34447545690
-
The fundamental aspects and applications of Agilent HPLC-Chip
-
Yin H., Killeen K. The fundamental aspects and applications of Agilent HPLC-Chip. J. Sep. Sci. 2007, 30:1427-1434.
-
(2007)
J. Sep. Sci.
, vol.30
, pp. 1427-1434
-
-
Yin, H.1
Killeen, K.2
-
133
-
-
0001467355
-
A new form of chromatogram employing two liquid phases
-
Martin A.J.P., Synge R.L.M. A new form of chromatogram employing two liquid phases. Biochem. J. 1941, 35:1358-1368.
-
(1941)
Biochem. J.
, vol.35
, pp. 1358-1368
-
-
Martin, A.J.P.1
Synge, R.L.M.2
-
134
-
-
84865080329
-
-
Wiley-VCH, New York
-
Neue U.D. HPLC, Columns, Chapter Column Design 1997, Wiley-VCH, New York, pp. 41-53.
-
(1997)
HPLC, Columns, Chapter Column Design
, pp. 41-53
-
-
Neue, U.D.1
-
135
-
-
21144455850
-
New frontiers in chromatography
-
Swartz M.E., Murphy B. New frontiers in chromatography. Am. Lab. 2005, 37:22-27.
-
(2005)
Am. Lab.
, vol.37
, pp. 22-27
-
-
Swartz, M.E.1
Murphy, B.2
-
136
-
-
17044393960
-
UPLC: an introduction and review
-
Swartz M.E. UPLC: an introduction and review. J. Liq. Chromatogr. 2005, 28:1253-1263.
-
(2005)
J. Liq. Chromatogr.
, vol.28
, pp. 1253-1263
-
-
Swartz, M.E.1
-
137
-
-
0030977505
-
A new small particle packing for faster analysis with high resolution
-
Phillips D.J., Capparella M., Neue U.D., El Fallah Z. A new small particle packing for faster analysis with high resolution. J. Pharm. Biomed. Anal. 1997, 15:1389-1395.
-
(1997)
J. Pharm. Biomed. Anal.
, vol.15
, pp. 1389-1395
-
-
Phillips, D.J.1
Capparella, M.2
Neue, U.D.3
El Fallah, Z.4
-
138
-
-
1842786777
-
Practical aspects of fast reversed-phase high-performance liquid chromatography using 3μm particle packed columns and monolithic columns in pharmaceutical development and production working under current good manufacturing practice
-
Gerber F., Krummen M., Potgeter H., Roth A., Siffrin C., Spoendlin C. Practical aspects of fast reversed-phase high-performance liquid chromatography using 3μm particle packed columns and monolithic columns in pharmaceutical development and production working under current good manufacturing practice. J. Chromatogr. A 2004, 1036:127-133.
-
(2004)
J. Chromatogr. A
, vol.1036
, pp. 127-133
-
-
Gerber, F.1
Krummen, M.2
Potgeter, H.3
Roth, A.4
Siffrin, C.5
Spoendlin, C.6
-
139
-
-
84963101542
-
Kinetic conditions for optimum speed and resolution in column chromatography
-
Knox J.H., Saleem M. Kinetic conditions for optimum speed and resolution in column chromatography. J. Chromatogr. Sci. 1969, 7:614-622.
-
(1969)
J. Chromatogr. Sci.
, vol.7
, pp. 614-622
-
-
Knox, J.H.1
Saleem, M.2
-
140
-
-
0031569131
-
Ultra high pressure reversed phase liquid chromatography in packed capillary columns
-
MacNair J.E., Lewis K.C., Jorgenson J.W. Ultra high pressure reversed phase liquid chromatography in packed capillary columns. Anal. Chem. 1997, 69:983-989.
-
(1997)
Anal. Chem.
, vol.69
, pp. 983-989
-
-
MacNair, J.E.1
Lewis, K.C.2
Jorgenson, J.W.3
-
141
-
-
0033082675
-
Ultra high pressure reversed-phase liquid chromatography: isocratic and gradient elution using columns packed with 1.0μm particles
-
MacNair J.E., Patel K.D., Jorgenson J.W. Ultra high pressure reversed-phase liquid chromatography: isocratic and gradient elution using columns packed with 1.0μm particles. Anal. Chem. 1999, 71:700-708.
-
(1999)
Anal. Chem.
, vol.71
, pp. 700-708
-
-
MacNair, J.E.1
Patel, K.D.2
Jorgenson, J.W.3
-
142
-
-
0035831394
-
Practical aspects of ultrahigh pressure capillary liquid chromatography
-
Wu N., Lippert J.A., Lee M.L. Practical aspects of ultrahigh pressure capillary liquid chromatography. J. Chromatogr. A 2001, 911:1-12.
-
(2001)
J. Chromatogr. A
, vol.911
, pp. 1-12
-
-
Wu, N.1
Lippert, J.A.2
Lee, M.L.3
-
143
-
-
33645975885
-
Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns
-
de Villiers A., Lauer H., Szucs R., Goodall S., Sandra P. Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns. J. Chromatogr. A 2006, 1113:84-91.
-
(2006)
J. Chromatogr. A
, vol.1113
, pp. 84-91
-
-
de Villiers, A.1
Lauer, H.2
Szucs, R.3
Goodall, S.4
Sandra, P.5
-
144
-
-
33845411125
-
Measurement of the axial and radial temperature profiles of a chromatographic column: influence of thermal insulation on column efficiency
-
Gritti F., Guiochon G. Measurement of the axial and radial temperature profiles of a chromatographic column: influence of thermal insulation on column efficiency. J. Chromatogr. A 2007, 1138:141-157.
-
(2007)
J. Chromatogr. A
, vol.1138
, pp. 141-157
-
-
Gritti, F.1
Guiochon, G.2
-
145
-
-
46849106921
-
Complete temperature profiles in ultra-high-pressure liquid chromatography columns
-
Gritti F., Guiochon G. Complete temperature profiles in ultra-high-pressure liquid chromatography columns. Anal. Chem. 2008, 80:5009-5020.
-
(2008)
Anal. Chem.
, vol.80
, pp. 5009-5020
-
-
Gritti, F.1
Guiochon, G.2
-
146
-
-
4544276272
-
The use of 1.5 micron porous ethyl-bridged hybrid particles as a stationary phase support for reversed-phase ultra-high pressure liquid chromatography
-
Mellors J.S., Jorgenson J.W. The use of 1.5 micron porous ethyl-bridged hybrid particles as a stationary phase support for reversed-phase ultra-high pressure liquid chromatography. Anal. Chem. 2004, 76:5441-5450.
-
(2004)
Anal. Chem.
, vol.76
, pp. 5441-5450
-
-
Mellors, J.S.1
Jorgenson, J.W.2
-
147
-
-
0034585970
-
Ultrafast reversed-phase high-performance liquid chromatographic separations: an overview
-
Kirkland J.J. Ultrafast reversed-phase high-performance liquid chromatographic separations: an overview. J. Chromatogr. Sci. 2000, 38:535-544.
-
(2000)
J. Chromatogr. Sci.
, vol.38
, pp. 535-544
-
-
Kirkland, J.J.1
-
148
-
-
0000742273
-
Fast chromatography and nonporous silica
-
Barder T.J., Wohlman P.J., Thrall C., DuBois P.D. Fast chromatography and nonporous silica. LC-GC 1997, 15:918-926.
-
(1997)
LC-GC
, vol.15
, pp. 918-926
-
-
Barder, T.J.1
Wohlman, P.J.2
Thrall, C.3
DuBois, P.D.4
-
149
-
-
0001668319
-
Ultra-high pressure liquid chromatography/time-of-flight mass spectrometry for fast separations
-
Wu N., Collins D.C., Lippert J.A., Xiang Y., Lee M.L. Ultra-high pressure liquid chromatography/time-of-flight mass spectrometry for fast separations. J. Microcol. Sep. 2000, 12:462-469.
-
(2000)
J. Microcol. Sep.
, vol.12
, pp. 462-469
-
-
Wu, N.1
Collins, D.C.2
Lippert, J.A.3
Xiang, Y.4
Lee, M.L.5
-
150
-
-
33749245435
-
Sub-2μm porous and nonporous particles for fast separation in reversed-phase high performance liquid chromatography
-
Wu N., Liu Y., Lee M.L. Sub-2μm porous and nonporous particles for fast separation in reversed-phase high performance liquid chromatography. J. Chromatogr. A 2006, 1131:142-150.
-
(2006)
J. Chromatogr. A
, vol.1131
, pp. 142-150
-
-
Wu, N.1
Liu, Y.2
Lee, M.L.3
-
151
-
-
0032781497
-
Super-high-speed liquid chromatography of proteins and peptides on non-porous Micra NPS-RP packings
-
Issaeva T., Kourganov A., Unger K. Super-high-speed liquid chromatography of proteins and peptides on non-porous Micra NPS-RP packings. J. Chromatogr. A 1999, 846:13-23.
-
(1999)
J. Chromatogr. A
, vol.846
, pp. 13-23
-
-
Issaeva, T.1
Kourganov, A.2
Unger, K.3
-
152
-
-
0032577333
-
Capillary electrochromatography with 1.8-μm ODS-modified porous silica particles
-
Seifar R.M., Kraak J.C., W.Th.Kok, Poppe H. Capillary electrochromatography with 1.8-μm ODS-modified porous silica particles. J. Chromatogr. A 1998, 808:71-77.
-
(1998)
J. Chromatogr. A
, vol.808
, pp. 71-77
-
-
Seifar, R.M.1
Kraak, J.C.2
Kok, W.T.3
Poppe, H.4
-
153
-
-
82455171807
-
Rapid LC-MS screening for IgG Fc modifications and allelic variants in blood
-
Goetze A.M., Zhang Z., Liu L., Jacobsen F.W., Flynn G.C. Rapid LC-MS screening for IgG Fc modifications and allelic variants in blood. Molec. Immun. 2011, 49:338-352.
-
(2011)
Molec. Immun.
, vol.49
, pp. 338-352
-
-
Goetze, A.M.1
Zhang, Z.2
Liu, L.3
Jacobsen, F.W.4
Flynn, G.C.5
-
154
-
-
77957019246
-
Separation of post-translational modifications in monoclonal antibodies by exploiting subtle conformational changes under mildly acidic conditions
-
Wang S., Ionescu R., Peekhaus N., Leung J., Ha S., Vlasak J. Separation of post-translational modifications in monoclonal antibodies by exploiting subtle conformational changes under mildly acidic conditions. J. Chromatogr. A 2010, 1217:6496-6502.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 6496-6502
-
-
Wang, S.1
Ionescu, R.2
Peekhaus, N.3
Leung, J.4
Ha, S.5
Vlasak, J.6
-
155
-
-
77649336017
-
The determination of the plate count for large molecules under reversed-phase gradient conditions
-
Neue U.D., Hewitson H.B., Wheat T.E. The determination of the plate count for large molecules under reversed-phase gradient conditions. J. Chromatogr. A 2010, 1217:2179-2181.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 2179-2181
-
-
Neue, U.D.1
Hewitson, H.B.2
Wheat, T.E.3
-
156
-
-
43049113826
-
Ultra-performance liquid chromatography/mass spectrometry of intact proteins
-
Everley R.A., Croley T.R. Ultra-performance liquid chromatography/mass spectrometry of intact proteins. J. Chromatogr. A 2008, 1192:239-247.
-
(2008)
J. Chromatogr. A
, vol.1192
, pp. 239-247
-
-
Everley, R.A.1
Croley, T.R.2
-
157
-
-
79952617499
-
Development of an ultra-high performance liquid chromatography analytical methodology for the profiling of olive (Olea europaea L.) pulp proteins
-
Esteve C., Rio C.D., Marina M.L., Garcia M.C. Development of an ultra-high performance liquid chromatography analytical methodology for the profiling of olive (Olea europaea L.) pulp proteins. Anal. Chim. Acta 2011, 690:129-134.
-
(2011)
Anal. Chim. Acta
, vol.690
, pp. 129-134
-
-
Esteve, C.1
Rio, C.D.2
Marina, M.L.3
Garcia, M.C.4
-
158
-
-
0028557260
-
Kinetic performance of open-tubular and packed columns in LC using the same stationary phase: immobilized polymethyloctadecylsiloxane
-
Gohlin K., Buskhe A., Larsson M. Kinetic performance of open-tubular and packed columns in LC using the same stationary phase: immobilized polymethyloctadecylsiloxane. Chromatographia 1994, 39:729-739.
-
(1994)
Chromatographia
, vol.39
, pp. 729-739
-
-
Gohlin, K.1
Buskhe, A.2
Larsson, M.3
-
159
-
-
0001518834
-
Studies of open-tubular microcapillary liquid chromatography. II. Chemically bonded octadecylsilane stationary phase
-
Tsuda T., Hibi K., Nakanishi T., Takeuchi T., Ishii D. Studies of open-tubular microcapillary liquid chromatography. II. Chemically bonded octadecylsilane stationary phase. J. Chromatogr. 1978, 158:227-232.
-
(1978)
J. Chromatogr.
, vol.158
, pp. 227-232
-
-
Tsuda, T.1
Hibi, K.2
Nakanishi, T.3
Takeuchi, T.4
Ishii, D.5
-
160
-
-
0000779581
-
Liquid chromatography in open-tubular columns: theory of column optimization with limited pressure and analysis time, and fabrication of chemically bonded reversed-phase columns on etched borosilicate glass capillaries
-
Jorgenson J.W., Guthrie E.J. Liquid chromatography in open-tubular columns: theory of column optimization with limited pressure and analysis time, and fabrication of chemically bonded reversed-phase columns on etched borosilicate glass capillaries. J. Chromatogr. 1983, 255:335-348.
-
(1983)
J. Chromatogr.
, vol.255
, pp. 335-348
-
-
Jorgenson, J.W.1
Guthrie, E.J.2
-
161
-
-
0033565781
-
Coupling of open tubular liquid chromatography to electrospray mass spectrometry with a nanospray interface
-
Hulthe G., Petersson M.A., Fogelqvist E. Coupling of open tubular liquid chromatography to electrospray mass spectrometry with a nanospray interface. Anal. Chem. 1999, 71:2915-2921.
-
(1999)
Anal. Chem.
, vol.71
, pp. 2915-2921
-
-
Hulthe, G.1
Petersson, M.A.2
Fogelqvist, E.3
-
162
-
-
33847001297
-
Ultratrace LC/MS Proteomic analysis using 10μm i.d. porous layer open tubular (PLOT) polystyrene-divinylbenzene capillary columns
-
Yue G., Luo Q., Zhang J., Wu S.-L., Karger B.L. Ultratrace LC/MS Proteomic analysis using 10μm i.d. porous layer open tubular (PLOT) polystyrene-divinylbenzene capillary columns. Anal. Chem. 2007, 79:938-946.
-
(2007)
Anal. Chem.
, vol.79
, pp. 938-946
-
-
Yue, G.1
Luo, Q.2
Zhang, J.3
Wu, S.-L.4
Karger, B.L.5
-
163
-
-
34548034478
-
On-line 1D and 2D porous layer open tubular/LC-ESI-MS using 10-microm-i.d. poly(styrene-divinylbenzene) columns for ultrasensitive proteomic analysis
-
Luo Q., Yue G., Valaskovic Gary A., Gu Y., Wu S.-L., Karger Barry L. On-line 1D and 2D porous layer open tubular/LC-ESI-MS using 10-microm-i.d. poly(styrene-divinylbenzene) columns for ultrasensitive proteomic analysis. Anal. Chem. 2007, 79:6174-6181.
-
(2007)
Anal. Chem.
, vol.79
, pp. 6174-6181
-
-
Luo, Q.1
Yue, G.2
Valaskovic Gary, A.3
Gu, Y.4
Wu, S.-L.5
Karger Barry, L.6
-
164
-
-
77953692655
-
Separation of intact proteins on porous layer open tubular (PLOT) columns
-
Rogeberg M., Wilson S.R., Greibrokk T., Lundanes E. Separation of intact proteins on porous layer open tubular (PLOT) columns. J. Chromatogr. A 2010, 1217:2782-2786.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 2782-2786
-
-
Rogeberg, M.1
Wilson, S.R.2
Greibrokk, T.3
Lundanes, E.4
-
165
-
-
0004319534
-
-
CRC Press, Boca Raton, FL, C.T. Mant, R.S. Hodges (Eds.)
-
High-Performance Liquid Chromatography of Peptides and Proteins: Separation, Analysis and Conformation 1991, CRC Press, Boca Raton, FL. C.T. Mant, R.S. Hodges (Eds.).
-
(1991)
High-Performance Liquid Chromatography of Peptides and Proteins: Separation, Analysis and Conformation
-
-
-
166
-
-
0029841273
-
Analysis of peptides by high-performance liquid chromatography
-
Mant C.T., Hodges R.S. Analysis of peptides by high-performance liquid chromatography. Methods Enzymol. 1996, 271:3-50.
-
(1996)
Methods Enzymol.
, vol.271
, pp. 3-50
-
-
Mant, C.T.1
Hodges, R.S.2
-
168
-
-
0042120983
-
Temperature selectivity effects in reversed-phase liquid chromatography due to conformation differences between helical and non-helical peptides
-
Chen Y., Mant C.T., Hodges R.S. Temperature selectivity effects in reversed-phase liquid chromatography due to conformation differences between helical and non-helical peptides. J. Chromatogr. A 2003, 1010:45-61.
-
(2003)
J. Chromatogr. A
, vol.1010
, pp. 45-61
-
-
Chen, Y.1
Mant, C.T.2
Hodges, R.S.3
-
169
-
-
0043135171
-
Temperature profiling of polypeptides in reversed-phase liquid chromatography. I. Monitoring of dimerization and unfolding of amphipathic α-helical peptides
-
Mant C.T., Chen Y., Hodges R.S. Temperature profiling of polypeptides in reversed-phase liquid chromatography. I. Monitoring of dimerization and unfolding of amphipathic α-helical peptides. J. Chromatogr. A 2003, 1009:29-43.
-
(2003)
J. Chromatogr. A
, vol.1009
, pp. 29-43
-
-
Mant, C.T.1
Chen, Y.2
Hodges, R.S.3
-
170
-
-
0042634260
-
Temperature profiling of polypeptides in reversed-phase liquid chromatography. II. Monitoring of folding and stability of two-stranded α-helical coiled-coils
-
Mant C.T., Tripet B., Hodges R.S. Temperature profiling of polypeptides in reversed-phase liquid chromatography. II. Monitoring of folding and stability of two-stranded α-helical coiled-coils. J. Chromatogr. A 2003, 1009:45-59.
-
(2003)
J. Chromatogr. A
, vol.1009
, pp. 45-59
-
-
Mant, C.T.1
Tripet, B.2
Hodges, R.S.3
-
171
-
-
3242681739
-
Selectivity differences in the separation of amphipathic α-helical peptides during reversed-phase liquid chromatography at pHs 2.0 and 7.0. Effects of different packings, mobile phase conditions and temperature
-
Chen Y., Mant C.T., Hodges R.S. Selectivity differences in the separation of amphipathic α-helical peptides during reversed-phase liquid chromatography at pHs 2.0 and 7.0. Effects of different packings, mobile phase conditions and temperature. J. Chromatogr. A 2004, 1043:99-111.
-
(2004)
J. Chromatogr. A
, vol.1043
, pp. 99-111
-
-
Chen, Y.1
Mant, C.T.2
Hodges, R.S.3
-
172
-
-
0021966157
-
Conformational effects in the reversed phase liquid chromatography of ribonuclease A
-
Cohen S.A., Benedek K., Tapuhi Y., Ford J.C., Karger B.L. Conformational effects in the reversed phase liquid chromatography of ribonuclease A. Anal. Biochem. 1985, 144:275-284.
-
(1985)
Anal. Biochem.
, vol.144
, pp. 275-284
-
-
Cohen, S.A.1
Benedek, K.2
Tapuhi, Y.3
Ford, J.C.4
Karger, B.L.5
-
173
-
-
0022556341
-
Conformational effects in the high-performance liquid chromatography of proteins. Further studies of the reversed-phase chromatographic behavior of ribonuclease A
-
Lu X.M., Benedek K., Karger B.L. Conformational effects in the high-performance liquid chromatography of proteins. Further studies of the reversed-phase chromatographic behavior of ribonuclease A. J. Chromatogr. 1986, 359:19-29.
-
(1986)
J. Chromatogr.
, vol.359
, pp. 19-29
-
-
Lu, X.M.1
Benedek, K.2
Karger, B.L.3
-
174
-
-
0026644167
-
Conformational effects in the reversed-phase chromatographic behavior of recombinant human growth hormone (rhGH) and N-methionine recombinant human growth hormone (Met-hGH)
-
Oroszlan P., Wicar S., Teshima G., Wu S.-L., Hancock W.S., Karger B.L. Conformational effects in the reversed-phase chromatographic behavior of recombinant human growth hormone (rhGH) and N-methionine recombinant human growth hormone (Met-hGH). Anal. Chem. 1992, 64:1623-1631.
-
(1992)
Anal. Chem.
, vol.64
, pp. 1623-1631
-
-
Oroszlan, P.1
Wicar, S.2
Teshima, G.3
Wu, S.-L.4
Hancock, W.S.5
Karger, B.L.6
-
175
-
-
0033168626
-
Probing the conformational states of proteins with reversed phase high performance liquid chromatography
-
Purcell A.W., Aguilar M.I., Hearn M.T.W. Probing the conformational states of proteins with reversed phase high performance liquid chromatography. Anal. Chem. 1999, 71:2440-2451.
-
(1999)
Anal. Chem.
, vol.71
, pp. 2440-2451
-
-
Purcell, A.W.1
Aguilar, M.I.2
Hearn, M.T.W.3
-
176
-
-
0032966224
-
Protein structure perturbations on chromatographic surfaces
-
Sane S.U., Cramer S.M., Przybycien T.M. Protein structure perturbations on chromatographic surfaces. J. Chromatogr. A. 1999, 849:149-159.
-
(1999)
J. Chromatogr. A.
, vol.849
, pp. 149-159
-
-
Sane, S.U.1
Cramer, S.M.2
Przybycien, T.M.3
-
177
-
-
0028114584
-
Conformational changes in the reversed phase liquid chromatography of recombinant human growth hormone as a function of organic solvent: the molten globule state
-
Wicar S., Mulkerrin M.G., Bathory G., Khundkar L.H., Karger B.L. Conformational changes in the reversed phase liquid chromatography of recombinant human growth hormone as a function of organic solvent: the molten globule state. Anal. Chem. 1994, 66:3908-3915.
-
(1994)
Anal. Chem.
, vol.66
, pp. 3908-3915
-
-
Wicar, S.1
Mulkerrin, M.G.2
Bathory, G.3
Khundkar, L.H.4
Karger, B.L.5
-
178
-
-
33749522854
-
Development of a reversed-phase high-performance liquid chromatography method for the analysis of components from a closed-loop insulin delivery system
-
Sawicka K., Sahota T., Taylor M.J., Tanna S. Development of a reversed-phase high-performance liquid chromatography method for the analysis of components from a closed-loop insulin delivery system. J. Chromatogr. A 2006, 1132:117-123.
-
(2006)
J. Chromatogr. A
, vol.1132
, pp. 117-123
-
-
Sawicka, K.1
Sahota, T.2
Taylor, M.J.3
Tanna, S.4
-
179
-
-
0029090778
-
Conformational effects in reversed-phase high-performance liquid chromatography of polypeptides. I. Resolution of insulin variants
-
Purcell A.W., Aguilar M.I., Hearn M.T.W. Conformational effects in reversed-phase high-performance liquid chromatography of polypeptides. I. Resolution of insulin variants. J. Chromatogr. A 1995, 711:61-70.
-
(1995)
J. Chromatogr. A
, vol.711
, pp. 61-70
-
-
Purcell, A.W.1
Aguilar, M.I.2
Hearn, M.T.W.3
-
180
-
-
0035937037
-
Characterization of polystyrene and polyisoprene by normal-phase temperature gradient interaction chromatography
-
Lee W., Cho D., Chun B.O., Chang T., Ree M. Characterization of polystyrene and polyisoprene by normal-phase temperature gradient interaction chromatography. J. Chromatogr. A 2001, 910:51-60.
-
(2001)
J. Chromatogr. A
, vol.910
, pp. 51-60
-
-
Lee, W.1
Cho, D.2
Chun, B.O.3
Chang, T.4
Ree, M.5
-
181
-
-
0024850734
-
Synthetic peptide purification by application of linear solvent strength gradient theory
-
Ford J.C., Smith J.A. Synthetic peptide purification by application of linear solvent strength gradient theory. J. Chromatogr. 1989, 483:131-143.
-
(1989)
J. Chromatogr.
, vol.483
, pp. 131-143
-
-
Ford, J.C.1
Smith, J.A.2
-
182
-
-
0023857916
-
Purification of integral plasma membrane proteins by reverse-phase high performance liquid chromatography
-
Sussman M.R. Purification of integral plasma membrane proteins by reverse-phase high performance liquid chromatography. Anal. Biochem. 1988, 169:395-399.
-
(1988)
Anal. Biochem.
, vol.169
, pp. 395-399
-
-
Sussman, M.R.1
-
183
-
-
84872829785
-
-
Strickland, Erythropoetin purification, U.S. Patent No. 04,667,016.
-
Por-Hsiung, T. Strickland, Erythropoetin purification, U.S. Patent No. 04,667,016.
-
-
-
Por-Hsiung, T.1
-
184
-
-
0033992112
-
On the stabilizing action of protein denaturation: acetonitrile effect on stability of lysozyme in aqueous solution
-
Kovrigin E.L., Potekhin S.A. On the stabilizing action of protein denaturation: acetonitrile effect on stability of lysozyme in aqueous solution. Biophys. Chem. 2000, 83:45-59.
-
(2000)
Biophys. Chem.
, vol.83
, pp. 45-59
-
-
Kovrigin, E.L.1
Potekhin, S.A.2
-
185
-
-
0032769803
-
Comparison between the isocratic and gradient retention behaviour of polypeptides in reversed-phase liquid chromatographic environments
-
Purcell A.W., Zhao G.L., Aguilar M.I., Hearn M.T.W. Comparison between the isocratic and gradient retention behaviour of polypeptides in reversed-phase liquid chromatographic environments. J. Chromatogr. A 1999, 852:43-57.
-
(1999)
J. Chromatogr. A
, vol.852
, pp. 43-57
-
-
Purcell, A.W.1
Zhao, G.L.2
Aguilar, M.I.3
Hearn, M.T.W.4
-
186
-
-
20444462726
-
Binding behaviour and conformational properties of globular proteins in the presence of immobilised non-polar ligands used in reversed-phase liquid chromatography
-
Boysen R.I., Jong A.J.O., Hearn M.T.W. Binding behaviour and conformational properties of globular proteins in the presence of immobilised non-polar ligands used in reversed-phase liquid chromatography. J. Chromatogr. A 2005, 1079:173-186.
-
(2005)
J. Chromatogr. A
, vol.1079
, pp. 173-186
-
-
Boysen, R.I.1
Jong, A.J.O.2
Hearn, M.T.W.3
-
187
-
-
0021647750
-
Protein conformation and reversed-phase high-performance liquid chromatography
-
Sadler A.J., Micanovic R., Katzenstein G.E., Lewis R.V., Middaugh C.R. Protein conformation and reversed-phase high-performance liquid chromatography. J. Chromatogr. A 1984, 317:93-101.
-
(1984)
J. Chromatogr. A
, vol.317
, pp. 93-101
-
-
Sadler, A.J.1
Micanovic, R.2
Katzenstein, G.E.3
Lewis, R.V.4
Middaugh, C.R.5
-
188
-
-
0029116625
-
Conformational transitions in peptides containing two putative alpha-helices of the prion protein
-
Zhang H., Kaneko K., Nguyen J.T., Livshits T.L., Baldwin M.A., Cohen F.E., James T.L., Prusiner S.B. Conformational transitions in peptides containing two putative alpha-helices of the prion protein. J. Mol. Biol. 1995, 250:514-526.
-
(1995)
J. Mol. Biol.
, vol.250
, pp. 514-526
-
-
Zhang, H.1
Kaneko, K.2
Nguyen, J.T.3
Livshits, T.L.4
Baldwin, M.A.5
Cohen, F.E.6
James, T.L.7
Prusiner, S.B.8
-
189
-
-
0031470113
-
Acetonitrile-induced conformational transitions in poly-l-lysine
-
Arunkumar A.I., Kumar T.K.S., Sivaraman T., Yu C. Acetonitrile-induced conformational transitions in poly-l-lysine. Int. J. Biol. Macromol. 1997, 21:299-305.
-
(1997)
Int. J. Biol. Macromol.
, vol.21
, pp. 299-305
-
-
Arunkumar, A.I.1
Kumar, T.K.S.2
Sivaraman, T.3
Yu, C.4
-
190
-
-
20344361924
-
HPLC and tandem detection to monitor conformational properties of biopharmaceuticals
-
Luykx D.M.A.M., Goerdayal S.S., Dingemanse P.J., Jiskoot W., Jongen P.M.J.M. HPLC and tandem detection to monitor conformational properties of biopharmaceuticals. J. Chromatogr. B 2005, 821:45-52.
-
(2005)
J. Chromatogr. B
, vol.821
, pp. 45-52
-
-
Luykx, D.M.A.M.1
Goerdayal, S.S.2
Dingemanse, P.J.3
Jiskoot, W.4
Jongen, P.M.J.M.5
-
191
-
-
0028883956
-
Enhanced sensitivity for peptide mapping with electrospray liquid chromatography-mass spectrometry in the presence of signal suppression due to trifluoroacetic acid-containing mobile phases
-
Apffel A., Fisher S., Goldberg G., Goodley P.C., Kuhlmann F.E. Enhanced sensitivity for peptide mapping with electrospray liquid chromatography-mass spectrometry in the presence of signal suppression due to trifluoroacetic acid-containing mobile phases. J. Chromatogr. A 1995, 712:177-190.
-
(1995)
J. Chromatogr. A
, vol.712
, pp. 177-190
-
-
Apffel, A.1
Fisher, S.2
Goldberg, G.3
Goodley, P.C.4
Kuhlmann, F.E.5
-
192
-
-
0023231017
-
Separation Purification of S49 mouse lymphoma histones by reversed-phase high performance liquid chromatography
-
McCroskey M.C., Groppi V.E., Pearson J.D., Separation Purification of S49 mouse lymphoma histones by reversed-phase high performance liquid chromatography. Anal. Biochem. 1987, 169:427-432.
-
(1987)
Anal. Biochem.
, vol.169
, pp. 427-432
-
-
McCroskey, M.C.1
Groppi, V.E.2
Pearson, J.D.3
-
193
-
-
0021325781
-
Reversed-phase high performance liquid chromatography: preparative purification of synthetic peptides
-
Rivier J., McClintock R., Galyean R., Anderson H. Reversed-phase high performance liquid chromatography: preparative purification of synthetic peptides. J. Chromatogr. 1984, 288:303-328.
-
(1984)
J. Chromatogr.
, vol.288
, pp. 303-328
-
-
Rivier, J.1
McClintock, R.2
Galyean, R.3
Anderson, H.4
-
194
-
-
0001835683
-
Preparative reverse phase high performance liquid chromatography: effects of buffer ph on the purification of synthetic peptides
-
Hoeger C., Galyean R., Boublik J., McClintock R., Rivier J. Preparative reverse phase high performance liquid chromatography: effects of buffer ph on the purification of synthetic peptides. Biochromatography 1987, 2:134-142.
-
(1987)
Biochromatography
, vol.2
, pp. 134-142
-
-
Hoeger, C.1
Galyean, R.2
Boublik, J.3
McClintock, R.4
Rivier, J.5
-
195
-
-
84865076423
-
Practical aspects of preparative reversed-phase chromatography of synthetic peptides
-
CRC Press, Boca Raton, FL
-
Hoeger C.A., Galyean R., McClintock R.A., Rivier J.E. Practical aspects of preparative reversed-phase chromatography of synthetic peptides. HPLC of Peptides and Proteins: Separation, Analysis and Conformation 1991, CRC Press, Boca Raton, FL, pp. 753-764.
-
(1991)
HPLC of Peptides and Proteins: Separation, Analysis and Conformation
, pp. 753-764
-
-
Hoeger, C.A.1
Galyean, R.2
McClintock, R.A.3
Rivier, J.E.4
-
196
-
-
0005629170
-
Rice cultivar identification by high-performance liquid chromatography of endosperm proteins
-
Huebner F.R., Bietz J.A., Webb B.D., Juliano B.O. Rice cultivar identification by high-performance liquid chromatography of endosperm proteins. Cereal Chem. 1990, 67:129-135.
-
(1990)
Cereal Chem.
, vol.67
, pp. 129-135
-
-
Huebner, F.R.1
Bietz, J.A.2
Webb, B.D.3
Juliano, B.O.4
-
197
-
-
0023657375
-
Effects of ion-pairing reagents on the prediction of peptide retention in reversed-phase high performance liquid chromatography
-
Guo D., Mant C.T., Hodges R.S. Effects of ion-pairing reagents on the prediction of peptide retention in reversed-phase high performance liquid chromatography. J. Chromatogr. 1987, 386:205-222.
-
(1987)
J. Chromatogr.
, vol.386
, pp. 205-222
-
-
Guo, D.1
Mant, C.T.2
Hodges, R.S.3
-
198
-
-
85015349811
-
The effects of anionic ion-pairing reagents on the peptide retention in reversed-phase chromatography
-
CRC Press, Boca Raton, FL, C.T. Mant, R.S. Hodges (Eds.)
-
The effects of anionic ion-pairing reagents on the peptide retention in reversed-phase chromatography. High-Performance Liquid Chromatography of Peptides and Proteins: Separation, Analysis and Conformation 1991, 327-341. CRC Press, Boca Raton, FL. C.T. Mant, R.S. Hodges (Eds.).
-
(1991)
High-Performance Liquid Chromatography of Peptides and Proteins: Separation, Analysis and Conformation
, pp. 327-341
-
-
-
199
-
-
0003504295
-
-
Bay Bioanalytical Laboratory, Richmond, VA, R.L. Cunico, K.M. Gooding, T. Wehr (Eds.)
-
HPLC and CE of Biomolecules 1998, Bay Bioanalytical Laboratory, Richmond, VA. R.L. Cunico, K.M. Gooding, T. Wehr (Eds.).
-
(1998)
HPLC and CE of Biomolecules
-
-
-
200
-
-
0005225421
-
-
Marcel Dekker, New York, NY, K.M. Gooding, F.E. Regnier (Eds.)
-
Mant C.T., Hodges R.S. HPLC of Biological Macromolecules 2002, 433-511. Marcel Dekker, New York, NY. K.M. Gooding, F.E. Regnier (Eds.).
-
(2002)
HPLC of Biological Macromolecules
, pp. 433-511
-
-
Mant, C.T.1
Hodges, R.S.2
-
201
-
-
0022455435
-
Prediction of peptide retention times in reversed-phase high-performance liquid chromatography. II. Correlation of observed and predicted peptide retention times factors and influencing the retention times of peptides
-
Guo D., Mant C.T., Taneja A.K., Parker J.M.R., Hodges R.S. Prediction of peptide retention times in reversed-phase high-performance liquid chromatography. II. Correlation of observed and predicted peptide retention times factors and influencing the retention times of peptides. J. Chromatogr. 1986, 359:519-532.
-
(1986)
J. Chromatogr.
, vol.359
, pp. 519-532
-
-
Guo, D.1
Mant, C.T.2
Taneja, A.K.3
Parker, J.M.R.4
Hodges, R.S.5
-
202
-
-
0023164433
-
Effect of column degradation on the reversed-phase high-performance liquid chromatographic separation of peptides and proteins
-
Glajch J.L., Kirkland J.J., Kohler J. Effect of column degradation on the reversed-phase high-performance liquid chromatographic separation of peptides and proteins. J. Chromatogr. 1987, 384:81-90.
-
(1987)
J. Chromatogr.
, vol.384
, pp. 81-90
-
-
Glajch, J.L.1
Kirkland, J.J.2
Kohler, J.3
-
203
-
-
33745125642
-
Synthesis and characterization of highly stable bonded phases for high-performance liquid chromatography column packings
-
Kirkland J.J., Glajch J.L., Farlee R.D. Synthesis and characterization of highly stable bonded phases for high-performance liquid chromatography column packings. Anal. Chem. 1989, 61:2-11.
-
(1989)
Anal. Chem.
, vol.61
, pp. 2-11
-
-
Kirkland, J.J.1
Glajch, J.L.2
Farlee, R.D.3
-
204
-
-
0009976382
-
Stable, sterically protected, monofunctional-silane bonded-phase columns for high performance liquid chromatography
-
Glajch J.L., Kirkland J.J. Stable, sterically protected, monofunctional-silane bonded-phase columns for high performance liquid chromatography. LC-GC 1990, 8:140-150.
-
(1990)
LC-GC
, vol.8
, pp. 140-150
-
-
Glajch, J.L.1
Kirkland, J.J.2
-
205
-
-
0027654617
-
Rapid, high-resolution HPLC separation of peptides using small particles at elevated temperatures
-
Boyes B.E., Kirkland J.J. Rapid, high-resolution HPLC separation of peptides using small particles at elevated temperatures. Pept. Res. 1993, 6:249-258.
-
(1993)
Pept. Res.
, vol.6
, pp. 249-258
-
-
Boyes, B.E.1
Kirkland, J.J.2
-
206
-
-
20444398483
-
Effect of anionic ion-pairing reagent concentration (1-60mM) on reversed-phase liquid chromatography elution behaviour of peptides
-
Shibue M., Mant C.T., Hodges R.S. Effect of anionic ion-pairing reagent concentration (1-60mM) on reversed-phase liquid chromatography elution behaviour of peptides. J. Chromatogr. A 2005, 1080:58-67.
-
(2005)
J. Chromatogr. A
, vol.1080
, pp. 58-67
-
-
Shibue, M.1
Mant, C.T.2
Hodges, R.S.3
-
207
-
-
0033933770
-
Effect of pressure on Solute capacity factor in HPLC using a non-porous stationary phase
-
Ohmacht R., Boros B. Effect of pressure on Solute capacity factor in HPLC using a non-porous stationary phase. Chromatographia 2000, 51:S205-S210.
-
(2000)
Chromatographia
, vol.51
-
-
Ohmacht, R.1
Boros, B.2
-
208
-
-
0036069752
-
Effect of pressure on solute capacity factor in HPLC using a non-porous stationary phase II
-
Felinger A., Boros B., Ohmacht R. Effect of pressure on solute capacity factor in HPLC using a non-porous stationary phase II. Chromatographia 2002, 56:S61-S68.
-
(2002)
Chromatographia
, vol.56
-
-
Felinger, A.1
Boros, B.2
Ohmacht, R.3
-
209
-
-
0042476524
-
Influence of pressure on the retention and separation of insulin variants under linear conditions
-
Liu X., Zhou D., Szabelski P., Guiochon G. Influence of pressure on the retention and separation of insulin variants under linear conditions. Anal. Chem. 2003, 75:3999-4009.
-
(2003)
Anal. Chem.
, vol.75
, pp. 3999-4009
-
-
Liu, X.1
Zhou, D.2
Szabelski, P.3
Guiochon, G.4
-
210
-
-
0037469996
-
Influence of pressure on the chromatographic behavior of insulin variants under nonlinear conditions
-
Liu X., Szabelski P., Kaczmarski K., Zhou D., Guiochon G. Influence of pressure on the chromatographic behavior of insulin variants under nonlinear conditions. J. Chromatogr. A 2003, 988:205-218.
-
(2003)
J. Chromatogr. A
, vol.988
, pp. 205-218
-
-
Liu, X.1
Szabelski, P.2
Kaczmarski, K.3
Zhou, D.4
Guiochon, G.5
-
211
-
-
53749097442
-
Investigation of the effect of pressure on retention of small molecules using reversed-phase ultra-high-pressure liquid chromatography
-
Fallas M.M., Neue U.D., Hadley M.R., McCalley D. Investigation of the effect of pressure on retention of small molecules using reversed-phase ultra-high-pressure liquid chromatography. J. Chromatogr. A 2008, 1209:195-205.
-
(2008)
J. Chromatogr. A
, vol.1209
, pp. 195-205
-
-
Fallas, M.M.1
Neue, U.D.2
Hadley, M.R.3
McCalley, D.4
-
212
-
-
0002508674
-
Optimization model for the gradient elution separation of peptide mixtures by reversed-phase high-performance liquid chromatography: verification of retention relationships
-
Stadalius M.A., Gold H.S., Snyder L.R. Optimization model for the gradient elution separation of peptide mixtures by reversed-phase high-performance liquid chromatography: verification of retention relationships. J. Chromatogr. 1984, 296:31-59.
-
(1984)
J. Chromatogr.
, vol.296
, pp. 31-59
-
-
Stadalius, M.A.1
Gold, H.S.2
Snyder, L.R.3
-
213
-
-
77953378502
-
Comparison of the mass transfer in totally porous and superficially porous stationary phases in liquid chromatography
-
Kiss I., Bacskay I., Kilar F., Felinger A. Comparison of the mass transfer in totally porous and superficially porous stationary phases in liquid chromatography. Anal. Bioanal. Chem. 2010, 397:1307-1314.
-
(2010)
Anal. Bioanal. Chem.
, vol.397
, pp. 1307-1314
-
-
Kiss, I.1
Bacskay, I.2
Kilar, F.3
Felinger, A.4
-
214
-
-
77951205929
-
Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments
-
Gritti F., Sanchez C.A., Farkas T., Guiochon G. Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments. J. Chromatogr. A 2010, 1217:3000-30012.
-
(2010)
J. Chromatogr. A
, vol.1217
, pp. 3000-30012
-
-
Gritti, F.1
Sanchez, C.A.2
Farkas, T.3
Guiochon, G.4
-
215
-
-
67650032931
-
Effects of extra-column band spreading, liquid chromatography system operating pressure, and column temperature on the performance of sub-2-μm porous particles
-
Fountain K.J., Neue U.D., Grumbach E.S., Diehl D.M. Effects of extra-column band spreading, liquid chromatography system operating pressure, and column temperature on the performance of sub-2-μm porous particles. J. Chromatogr. A 2009, 1216:5979-5988.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 5979-5988
-
-
Fountain, K.J.1
Neue, U.D.2
Grumbach, E.S.3
Diehl, D.M.4
-
216
-
-
79960138586
-
The impact of extra-column band broadening on the chromatographic efficiency of 5cm long narrow-bore very efficient columns
-
Fekete S., Fekete J. The impact of extra-column band broadening on the chromatographic efficiency of 5cm long narrow-bore very efficient columns. J. Chromatogr. A 2011, 1218:5286-5291.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 5286-5291
-
-
Fekete, S.1
Fekete, J.2
-
217
-
-
0021951810
-
A radiochemical study of irreversible protein loss on high-performance liquid chromatography column frits
-
Sadek P.C., Carr P.W., Bowers L.D., Haddad L.C. A radiochemical study of irreversible protein loss on high-performance liquid chromatography column frits. Anal. Biochem. 1985, 144:128-131.
-
(1985)
Anal. Biochem.
, vol.144
, pp. 128-131
-
-
Sadek, P.C.1
Carr, P.W.2
Bowers, L.D.3
Haddad, L.C.4
-
218
-
-
0037317467
-
The basics of mass spectrometry in the twenty-first century
-
Glish G.L., Vachet R.W. The basics of mass spectrometry in the twenty-first century. Nat. Rev. Drug Discov. 2003, 2:140-150.
-
(2003)
Nat. Rev. Drug Discov.
, vol.2
, pp. 140-150
-
-
Glish, G.L.1
Vachet, R.W.2
-
219
-
-
0041408938
-
Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis
-
Makarov A. Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis. Anal. Chem. 2000, 72:1156-1162.
-
(2000)
Anal. Chem.
, vol.72
, pp. 1156-1162
-
-
Makarov, A.1
-
220
-
-
0036535032
-
Fourier transform ion cyclotron resonance detection: principles and experimental configurations
-
Marshall A.G., Hendrickson C.L. Fourier transform ion cyclotron resonance detection: principles and experimental configurations. Int. J. Mass Spectrom. 2002, 215:59-75.
-
(2002)
Int. J. Mass Spectrom.
, vol.215
, pp. 59-75
-
-
Marshall, A.G.1
Hendrickson, C.L.2
-
221
-
-
79959458959
-
The application of MALDI TOF MS in biopharmaceutical research
-
Kafka A.P., Kleffmann T., Rades T., McDowell A. The application of MALDI TOF MS in biopharmaceutical research. Int. J. Pharm. 2011, 417:70-82.
-
(2011)
Int. J. Pharm.
, vol.417
, pp. 70-82
-
-
Kafka, A.P.1
Kleffmann, T.2
Rades, T.3
McDowell, A.4
-
222
-
-
79955801547
-
The future of biological mass spectrometry
-
Vestal M.L. The future of biological mass spectrometry. J. Am. Soc. Mass Spectrom. 2011, 22:953-959.
-
(2011)
J. Am. Soc. Mass Spectrom.
, vol.22
, pp. 953-959
-
-
Vestal, M.L.1
-
223
-
-
59349099420
-
Coupling ultra high pressure liquid chromatography with single quadrupole mass spectrometry for the analysis of a complex drug mixture
-
Schappler J., Nicoli R., Nguyen D., Rudaz S., Veuthey J.L., Guillarme D. Coupling ultra high pressure liquid chromatography with single quadrupole mass spectrometry for the analysis of a complex drug mixture. Talanta 2009, 78:377-387.
-
(2009)
Talanta
, vol.78
, pp. 377-387
-
-
Schappler, J.1
Nicoli, R.2
Nguyen, D.3
Rudaz, S.4
Veuthey, J.L.5
Guillarme, D.6
-
224
-
-
73249131951
-
Coupling ultra high pressure liquid chromatography with mass spectrometry
-
Guillarme D., Schappler J., Rudaz S., Veuthey J.L. Coupling ultra high pressure liquid chromatography with mass spectrometry. Trends Anal. Chem. 2010, 29:15-27.
-
(2010)
Trends Anal. Chem.
, vol.29
, pp. 15-27
-
-
Guillarme, D.1
Schappler, J.2
Rudaz, S.3
Veuthey, J.L.4
-
225
-
-
69449096140
-
CE-TOF/MS Fundamental concepts, instrumental considerations and applications
-
Staub A., Schappler J., Rudaz S., Veuthey J.L. CE-TOF/MS Fundamental concepts, instrumental considerations and applications. Electrophoresis 2009, 30:1610-1623.
-
(2009)
Electrophoresis
, vol.30
, pp. 1610-1623
-
-
Staub, A.1
Schappler, J.2
Rudaz, S.3
Veuthey, J.L.4
-
226
-
-
84865074613
-
Top-down versus bottom-up approaches in proteomics
-
Wehr T. Top-down versus bottom-up approaches in proteomics. LC-GC 2006, 24:492-497.
-
(2006)
LC-GC
, vol.24
, pp. 492-497
-
-
Wehr, T.1
-
227
-
-
83555165265
-
Novel liquid-chromatography columns for proteomics research
-
van de Meent M.H.M., de Jong G.J. Novel liquid-chromatography columns for proteomics research. Trends Anal. Chem. 2011, 30:1809-1818.
-
(2011)
Trends Anal. Chem.
, vol.30
, pp. 1809-1818
-
-
van de Meent, M.H.M.1
de Jong, G.J.2
-
228
-
-
80052078797
-
Silica-based and organic monolithic capillary columns for LC: recent trends in proteomics
-
Rozenbrand J., Van Bennekom W.P. Silica-based and organic monolithic capillary columns for LC: recent trends in proteomics. J. Sep. Sci. 2011, 34:1934-1944.
-
(2011)
J. Sep. Sci.
, vol.34
, pp. 1934-1944
-
-
Rozenbrand, J.1
Van Bennekom, W.P.2
-
229
-
-
77950420818
-
One-dimensional capillary liquid chromatographic separation coupled with tandem mass spectrometry unveils the Escherichia coli proteome on a microarray scale
-
Iwasaki M., Miwa S., Ikegami T., Tomita M., Tanaka N., Ishihama Y. One-dimensional capillary liquid chromatographic separation coupled with tandem mass spectrometry unveils the Escherichia coli proteome on a microarray scale. Anal. Chem. 2010, 82:2616-2620.
-
(2010)
Anal. Chem.
, vol.82
, pp. 2616-2620
-
-
Iwasaki, M.1
Miwa, S.2
Ikegami, T.3
Tomita, M.4
Tanaka, N.5
Ishihama, Y.6
-
230
-
-
79960366325
-
High-resolution separations of proteins isoforms with liquid chromatography time-of-flight mass spectrometry using polymer monolithic capillary columns
-
Eeltink S., Wouters B., Desmet G., Ursem M., Blinco D., Kemp G.D., Treumann A. High-resolution separations of proteins isoforms with liquid chromatography time-of-flight mass spectrometry using polymer monolithic capillary columns. J. Chromatogr. A 2011, 1218:5504-5511.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 5504-5511
-
-
Eeltink, S.1
Wouters, B.2
Desmet, G.3
Ursem, M.4
Blinco, D.5
Kemp, G.D.6
Treumann, A.7
-
231
-
-
0023662538
-
Main-chain-directed strategy for the assignment of 1H-NMR spectra of proteins
-
Englander S.W., Wand A.J. Main-chain-directed strategy for the assignment of 1H-NMR spectra of proteins. Biochemistry 1987, 26:5953-5958.
-
(1987)
Biochemistry
, vol.26
, pp. 5953-5958
-
-
Englander, S.W.1
Wand, A.J.2
-
232
-
-
0020855355
-
Hydrogen exchange and structural dynamics of proteins and nucleic acids
-
Englander S.W., Kallenbach N.R. Hydrogen exchange and structural dynamics of proteins and nucleic acids. Q. Rev. Biophys. 1984, 16:18-21.
-
(1984)
Q. Rev. Biophys.
, vol.16
, pp. 18-21
-
-
Englander, S.W.1
Kallenbach, N.R.2
-
233
-
-
0034727659
-
Probing the nature of the blue-shifted intermediate of photoactive yellow protein in solation by NMR: hydrogen-deuterium exchange data and pH studies
-
Craven C.J., Derix N.M., Hendriks J., Boelens R., Hellingwerf K.J., Kaptein R. Probing the nature of the blue-shifted intermediate of photoactive yellow protein in solation by NMR: hydrogen-deuterium exchange data and pH studies. Biochemistry 2000, 39:14392-14399.
-
(2000)
Biochemistry
, vol.39
, pp. 14392-14399
-
-
Craven, C.J.1
Derix, N.M.2
Hendriks, J.3
Boelens, R.4
Hellingwerf, K.J.5
Kaptein, R.6
-
234
-
-
0031595590
-
15N multidimensional NMR to study the structure and dynamics of proteins
-
15N multidimensional NMR to study the structure and dynamics of proteins. Annu. Rev. Biophys. Biomol. Struct. 1998, 27:357-406.
-
(1998)
Annu. Rev. Biophys. Biomol. Struct.
, vol.27
, pp. 357-406
-
-
Gardner, K.H.1
Kay, L.E.2
-
235
-
-
0027529263
-
Determination of amide hydrogen exchange by mass spectrometry: a new tool for protein structure elucidation
-
Zhang Z., Smith D.L. Determination of amide hydrogen exchange by mass spectrometry: a new tool for protein structure elucidation. Protein Sci. 1993, 2:522-531.
-
(1993)
Protein Sci.
, vol.2
, pp. 522-531
-
-
Zhang, Z.1
Smith, D.L.2
-
236
-
-
0031018084
-
Probing the non-covalent structure of proteins by amide hydrogen exchange and mass spectrometry
-
Smith D.L., Deng Y., Zhang Z. Probing the non-covalent structure of proteins by amide hydrogen exchange and mass spectrometry. J. Mass Spectrom. 1997, 32:135-146.
-
(1997)
J. Mass Spectrom.
, vol.32
, pp. 135-146
-
-
Smith, D.L.1
Deng, Y.2
Zhang, Z.3
-
237
-
-
0027770910
-
Detection of transient protein folding populations by mass spectrometry
-
Miranker A., Robinson C.V., Radford S.E., Aplin R.T., Dobson C.M. Detection of transient protein folding populations by mass spectrometry. Science 1993, 262:896-900.
-
(1993)
Science
, vol.262
, pp. 896-900
-
-
Miranker, A.1
Robinson, C.V.2
Radford, S.E.3
Aplin, R.T.4
Dobson, C.M.5
-
238
-
-
0037146801
-
Mapping of protein:protein contact surfaces by hydrogen/deuterium exchange, followed by on-line high-performance liquid chromatography-electrospray ionization Fourier-transform ion-cyclotron-resonance mass analysis
-
Lam T.T., Lanman J.K., Emmett M.R., Hendrickson C.L., Marshall A.G., Prevelige P.E. Mapping of protein:protein contact surfaces by hydrogen/deuterium exchange, followed by on-line high-performance liquid chromatography-electrospray ionization Fourier-transform ion-cyclotron-resonance mass analysis. J. Chromatogr. A 2002, 982:85-95.
-
(2002)
J. Chromatogr. A
, vol.982
, pp. 85-95
-
-
Lam, T.T.1
Lanman, J.K.2
Emmett, M.R.3
Hendrickson, C.L.4
Marshall, A.G.5
Prevelige, P.E.6
|