메뉴 건너뛰기




Volumn 46, Issue 6, 2011, Pages 472-521

Recent developments in ion mobility spectrometry

Author keywords

differential mobility spectrometry; high field asymmetric waveform ion mobility spectrometry; hyphenated techniques; Ion mobility spectrometry

Indexed keywords

ANALYSIS OF LIQUIDS; CHROMATOGRAPHIC TECHNIQUES; CLINICAL DIAGNOSTICS; COMPLEX SAMPLES; DIFFERENTIAL MOBILITY SPECTROMETRY; ENVIRONMENTAL ANALYSIS; FIELD-DEPENDENT MOBILITY; FURTHER DEVELOPMENT; HIGH-FIELD ASYMMETRIC WAVEFORM ION MOBILITY SPECTROMETRIES; HYPHENATED TECHNIQUES; ION MOBILITY; ION MOBILITY SPECTROMETER; ION MOBILITY SPECTROMETRY; ION MOBILITY-MASS SPECTROMETRY; MOLECULAR IMPRINTED POLYMERS; NEW APPLICATIONS; SAMPLE PREPARATION TECHNIQUES; SELECTIVE IONIZATION; TECHNICAL IMPLEMENTATION; TIME OF FLIGHT; VAPOR SENSORS;

EID: 79960427733     PISSN: 05704928     EISSN: 1520569X     Source Type: Journal    
DOI: 10.1080/05704928.2011.582658     Document Type: Article
Times cited : (159)

References (343)
  • 1
    • 7644233200 scopus 로고    scopus 로고
    • Ion mobility spectrometers in national defense
    • Eiceman, G.A. and Stone, J.A. (2004) Ion mobility spectrometers in national defense. Anal. Chem., 76: 390a-397a.
    • (2004) Anal. Chem. , vol.76
    • Eiceman, G.A.1    Stone, J.A.2
  • 2
    • 0015175236 scopus 로고
    • Plasma chromatography of polychlorinated biphenyls
    • Karasek, F.W. (1971) Plasma chromatography of polychlorinated biphenyls. Anal. Chem., 43: 1981-1986.
    • (1971) Anal. Chem. , vol.43 , pp. 1981-1986
    • Karasek, F.W.1
  • 3
    • 4243612640 scopus 로고
    • Mass identified mobility spectra of pnitrophenol and reactant ions in plasma chromatography
    • Karasek, F.W., Kim, S.H., and Hill, H.H. (1976) Mass identified mobility spectra of pnitrophenol and reactant ions in plasma chromatography. Anal. Chem., 48: 1133-1137.
    • (1976) Anal. Chem. , vol.48 , pp. 1133-1137
    • Karasek, F.W.1    Kim, S.H.2    Hill, H.H.3
  • 4
    • 0001724814 scopus 로고
    • Plasma chromatography of monohalogenated benzenes
    • Karasek, F.W. and Tatone, O.S. (1972) Plasma chromatography of monohalogenated benzenes. Anal. Chem., 44: 1758-1763.
    • (1972) Anal. Chem. , vol.44 , pp. 1758-1763
    • Karasek, F.W.1    Tatone, O.S.2
  • 5
    • 85022438154 scopus 로고
    • Plasma chromatography
    • Karasek, F.W. (1974) Plasma chromatography. Anal. Chem., 46: 710A-720A.
    • (1974) Anal. Chem. , vol.46
    • Karasek, F.W.1
  • 6
    • 4444380266 scopus 로고    scopus 로고
    • Microfabricated differential mobility spectrometry with pyrolysis gas chromatography for chemical characterization of bacteria
    • DOI 10.1021/ac0497611
    • Schmidt, H., Tadjimukhamedov, F., Mohrenz, I.V., Smith, G.B., and Eiceman, G.A. (2004) Microfabricated differential mobility spectrometrywith pyrolysis gas chromatography for chemical characterization of bacteria. Anal. Chem., 76: 5208-5217. (Pubitemid 39180353)
    • (2004) Analytical Chemistry , vol.76 , Issue.17 , pp. 5208-5217
    • Schmidt, H.1    Tadjimukhamedov, F.2    Mohrenz, I.V.3    Smith, G.B.4    Eiceman, G.A.5
  • 7
    • 0037443289 scopus 로고    scopus 로고
    • Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source
    • DOI 10.1021/ac020342i
    • Baumbach, J.I., Sielemann, S., Xie, Z.Y., and Schmidt, H. (2003) Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source. Anal. Chem., 75: 1483-1490. (Pubitemid 36397183)
    • (2003) Analytical Chemistry , vol.75 , Issue.6 , pp. 1483-1490
    • Baumbach, J.I.1    Sielemann, S.2    Xie, Z.3    Schmidt, H.4
  • 8
    • 16844384039 scopus 로고    scopus 로고
    • Continuous on-line determination of methyl tert-butyl ether in water samples using ion mobility spectrometry
    • Borsdorf, H. and Rammler, A. (2005) Continuous on-line determination of methyl tert-butyl ether in water samples using ion mobility spectrometry. J. Chrom., 1072: 45-54.
    • (2005) J. Chrom. , vol.1072 , pp. 45-54
    • Borsdorf, H.1    Rammler, A.2
  • 9
    • 1342322749 scopus 로고    scopus 로고
    • Electrospray ionization-ion mobility spectrometry: A rapid analytical method for aqueous nitrate and nitrite analysis
    • DOI 10.1039/b311098b
    • Dwivedi, P., Matz, L.M., Atkinson, D.A., and Hill, H.H. (2004) Electrospray ionization-ion mobility spectrometry: A rapid analytical method for aqueous nitrate and nitrite analysis. Analyst, 129: 139-144. (Pubitemid 38250693)
    • (2004) Analyst , vol.129 , Issue.2 , pp. 139-144
    • Dwivedi, P.1    Matz, L.M.2    Atkinson, D.A.3    Hill Jr., H.H.4
  • 10
    • 0347858204 scopus 로고    scopus 로고
    • Detection of chemical warfare agents in water by high temperature-solid phase microextraction-ion mobility spectrometry (HT-SPME-IMS)
    • Fällman, Å. and Rittfeldt, L. (2001) Detection of chemical warfare agents in water by high temperature-solid phase microextraction-ion mobility spectrometry (HT-SPME-IMS). Int. J. Ion. Mobil. Spectrom., 4: 85.
    • (2001) Int. J. Ion. Mobil. Spectrom. , vol.4 , pp. 85
    • Fällman, A.1    Rittfeldt, L.2
  • 11
    • 1542509483 scopus 로고    scopus 로고
    • Atmospheric pressure ionization and gas phase ion mobility studies of isomeric dihalogenated benzenes using different ionization techniques
    • Borsdorf, H., Nazarov, E.G., and Eiceman, G.A. (2004) Atmospheric pressure ionization and gas phase ion mobility studies of isomeric dihalogenated benzenes using different ionization techniques. Int. J. Mass Spectrom., 232: 117-126.
    • (2004) Int. J. Mass Spectrom. , vol.232 , pp. 117-126
    • Borsdorf, H.1    Nazarov, E.G.2    Eiceman, G.A.3
  • 12
    • 0037768819 scopus 로고    scopus 로고
    • Atmospheric pressure chemical ionization studies of non-polar isomeric hydrocarbons using ion mobility spectrometry and mass spectrometry with different ionization techniques
    • DOI 10.1016/S1044-0305(02)00429-4, PII S1044030502004294
    • Borsdorf, H., Nazarov, E.G., and Eiceman, G.A. (2002) Atmospheric pressure chemical ionization studies of non-polar isomeric hydrocarbons using ion mobility spectrometry and mass spectrometry with different ionization techniques. J. Am. Soc. Mass Spectrom., 13: 1078-1087. (Pubitemid 36871602)
    • (2002) Journal of the American Society for Mass Spectrometry , vol.13 , Issue.9 , pp. 1078-1087
    • Borsdorf, H.1    Nazarov, E.G.2    Eiceman, G.A.3
  • 13
    • 0033181259 scopus 로고    scopus 로고
    • Ion mobility spectrometry: arriving on site and moving beyond a low profile
    • Baumbach, J.I. and Eiceman, G.A. (1999) Ion mobility spectrometry: Arriving on site and moving beyond a low profile. Appl. Spectros., 53: 338a-355a. (Pubitemid 32078045)
    • (1999) Applied Spectroscopy , vol.53 , Issue.9
    • Baumbach, J.I.1    Eiceman, G.A.2
  • 14
    • 1042290540 scopus 로고    scopus 로고
    • Temperature effects on resolution in ion mobility spectrometry
    • Tabrizchi, M. (2004) Temperature effects on resolution in ion mobility spectrometry. Talanta, 62: 65-70.
    • (2004) Talanta , vol.62 , pp. 65-70
    • Tabrizchi, M.1
  • 15
    • 0036240080 scopus 로고    scopus 로고
    • Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector
    • DOI 10.1039/b111547m
    • Eiceman, G.A., Nazarov, E.G., Miller, R.A., Krylov, E.V., and Zapata, A.M. (2002) Micromachined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector. Analyst, 127: 466-471. (Pubitemid 34438049)
    • (2002) Analyst , vol.127 , Issue.4 , pp. 466-471
    • Eiceman, G.A.1    Nazarov, E.G.2    Miller, R.A.3    Krylov, E.V.4    Zapata, A.M.5
  • 16
    • 8444223860 scopus 로고    scopus 로고
    • High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
    • DOI 10.1016/j.chroma.2004.08.119, PII S0021967304014785, Mass Spectrometry: Innovation and Application. Part III
    • Guevremont, R. (2004) High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry. J. Chrom., 1058: 3-19. (Pubitemid 39487201)
    • (2004) Journal of Chromatography A , vol.1058 , Issue.1-2 , pp. 3-19
    • Guevremont, R.1
  • 17
    • 0037030375 scopus 로고    scopus 로고
    • Field dependence of mobilities for gas-phase-protonated monomers and proton-bound dimers of ketones by planar field asymmetric waveform ion mobility spectrometer (PFAIMS)
    • DOI 10.1021/jp020009i
    • Krylov, E., Nazarov, E.G., Miller, R.A., Tadjikov, B., and Eiceman, G.A. (2002) Field dependence of mobilities for gas-phase-protonated monomers and proton-bound dimers of ketones by planar field asymmetric waveform ion mobility spectrometer (PFAIMS). J. Phys. Chem. A, 106: 5437-5444. (Pubitemid 35289950)
    • (2002) Journal of Physical Chemistry A , vol.106 , Issue.22 , pp. 5437-5444
    • Krylov, E.1    Nazarov, E.G.2    Miller, R.A.3    Tadjikov, B.4    Eiceman, G.A.5
  • 18
  • 19
    • 10644224548 scopus 로고    scopus 로고
    • Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures
    • DOI 10.1021/ac049299k
    • Shvartsburg, A.A., Tang, K., and Smith, R.D. (2004) Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures. Anal. Chem., 76: 7366-7374. (Pubitemid 39658009)
    • (2004) Analytical Chemistry , vol.76 , Issue.24 , pp. 7366-7374
    • Shvartsburg, A.A.1    Tang, K.2    Smith, R.D.3
  • 20
    • 0037083932 scopus 로고    scopus 로고
    • Application of mobility theory to the interpretation of data generated by linear and RF excited ion mobility spectrometers
    • Spangler, G.E. and Miller, R.A. (2002) Application of mobility theory to the interpretation of data generated by linear and RF excited ion mobility spectrometers. Int. J. Mass Spectrom., 214: 95-104.
    • (2002) Int. J. Mass Spectrom. , vol.214 , pp. 95-104
    • Spangler, G.E.1    Miller, R.A.2
  • 21
  • 22
    • 0035880216 scopus 로고    scopus 로고
    • A MEMS radio-frequency ion mobility spectrometer for chemical vapor detection
    • Miller, R.A., Nazarov, E.G., Eiceman, G.A., and King, A.T. (2001) A MEMS radio-frequency ion mobility spectrometer for chemical vapor detection. Sensor. Actuator. Phys., 91: 301-312.
    • (2001) Sensor. Actuator. Phys. , vol.91 , pp. 301-312
    • Miller, R.A.1    Nazarov, E.G.2    Eiceman, G.A.3    King, A.T.4
  • 23
    • 0029066651 scopus 로고
    • Membrane inlet ion mobility spectrometry for online measurement of ethanol in beer and in yeast fermentation
    • Kotiaho, T., Lauritsen, F.R., Degn, H., and Paakkanen, H. (1995) Membrane inlet ion mobility spectrometry for online measurement of ethanol in beer and in yeast fermentation. Anal. Chim. Acta, 309: 317-325.
    • (1995) Anal. Chim. Acta , vol.309 , pp. 317-325
    • Kotiaho, T.1    Lauritsen, F.R.2    Degn, H.3    Paakkanen, H.4
  • 24
    • 78649703088 scopus 로고    scopus 로고
    • Ion mobility spectrometry and its applications in detection of chemical warfare agents
    • Makinen, M.A., Anttalainen, O.A., and Sillanpaa, M.E. (2010) Ion mobility spectrometry and its applications in detection of chemical warfare agents. Anal. Chem., 82: 9594-9600.
    • (2010) Anal. Chem. , vol.82 , pp. 9594-9600
    • Makinen, M.A.1    Anttalainen, O.A.2    Sillanpaa, M.E.3
  • 25
    • 33745254226 scopus 로고    scopus 로고
    • Ion mobility spectrometry: Principles and applications
    • DOI 10.1080/05704920600663469, PII N43661066428006
    • Borsdorf, H. and Eiceman, G.A. (2006) Ion mobility spectrometry: Principles and applications. Appl. Spectros. Rev., 41: 323-375. (Pubitemid 43922086)
    • (2006) Applied Spectroscopy Reviews , vol.41 , Issue.4 , pp. 323-375
    • Borsdorf, H.1    Eiceman, G.A.2
  • 26
    • 4844229891 scopus 로고    scopus 로고
    • The analyst profiles of Gary Eiceman
    • Eiceman, G.A. (2004) The analyst profiles of Gary Eiceman. Analyst, 129: 488-491.
    • (2004) Analyst , vol.129 , pp. 488-491
    • Eiceman, G.A.1
  • 27
    • 0037730514 scopus 로고
    • Sensing of petrochemical fuels in soils using headspace analysis with photoionization-ion mobility spectrometry
    • Eiceman, G.A., Fleischer, M.E., and Leasure, C.S. (1987) Sensing of petrochemical fuels in soils using headspace analysis with photoionization-ion mobility spectrometry. Int. J. Environ. Anal. Chem., 28: 279-296.
    • (1987) Int. J. Environ. Anal. Chem. , vol.28 , pp. 279-296
    • Eiceman, G.A.1    Fleischer, M.E.2    Leasure, C.S.3
  • 29
    • 0001266692 scopus 로고
    • Ion mobility sensor in environmental analytical-chemistry-Concept and 1st results
    • Baumbach, J.I., Berger, D., Leonhardt, J.W., and Klockow, D. (1993) Ion mobility sensor in environmental analytical-chemistry-Concept and 1st results. Int. J. Environ. Anal. Chem., 52: 189-193.
    • (1993) Int. J. Environ. Anal. Chem. , vol.52 , pp. 189-193
    • Baumbach, J.I.1    Berger, D.2    Leonhardt, J.W.3    Klockow, D.4
  • 30
    • 0035425656 scopus 로고    scopus 로고
    • Rapid on-site determination of chlorobenzene in water samples using ion mobility spectrometry
    • DOI 10.1016/S0003-2670(01)01030-3, PII S0003267001010303
    • Borsdorf, H., Rammler, A., Schulze, D., Boadu, K.O., Feist, B., and Weiss, H. (2001) Rapid on-site determination of chlorobenzene in water samples using ion mobility spectrometry. Anal. Chim. Acta, 440: 63-70. (Pubitemid 32701985)
    • (2001) Analytica Chimica Acta , vol.440 , Issue.1 , pp. 63-70
    • Borsdorf, H.1    Rammler, A.2    Schulze, D.3    Boadu, K.O.4    Feist, B.5    Weiss, H.6
  • 31
    • 0000840816 scopus 로고
    • Monitoring of airborne organic vapors using ion mobility spectrometry
    • Eiceman, G.A., Snyder, A.P., and Blyth, D.A. (1990) Monitoring of airborne organic vapors using ion mobility spectrometry. Int. J. Environ. Anal. Chem., 38: 415-425.
    • (1990) Int. J. Environ. Anal. Chem. , vol.38 , pp. 415-425
    • Eiceman, G.A.1    Snyder, A.P.2    Blyth, D.A.3
  • 33
    • 0022363581 scopus 로고
    • Application of air sampling and ion-mobility spectrometry to narcotics detection: A feasibility study
    • Lawrence, A.H. and Elias, L. (1985) Application of air sampling and ion-mobility spectrometry to narcotics detection-A feasibility study. Bull. Narc., 37: 3-16. (Pubitemid 15235649)
    • (1985) Bulletin on Narcotics , vol.37 , Issue.1 , pp. 3-16
    • Lawrence, A.H.1    Elias, L.2
  • 34
    • 33644690314 scopus 로고    scopus 로고
    • Process analysis using ion mobility spectrometry
    • DOI 10.1007/s00216-005-3397-8
    • Baumbach, J.I. (2006) Process analysis using ion mobility spectrometry. Anal. Bioanal. Chem., 384: 1059-1070. (Pubitemid 43333987)
    • (2006) Analytical and Bioanalytical Chemistry , vol.384 , Issue.5 , pp. 1059-1070
    • Baumbach, J.I.1
  • 35
    • 84948516573 scopus 로고
    • Environmental and process applications for ion mobility spectrometry
    • Roehl, J.E. (1991) Environmental and process applications for ion mobility spectrometry. Appl. Spectros. Rev., 26: 1-57.
    • (1991) Appl. Spectros. Rev. , vol.26 , pp. 1-57
    • Roehl, J.E.1
  • 36
    • 0022440763 scopus 로고
    • Negative-ion mobility spectrometry for selected inorganic pollutant gases and gas-mixtures in air
    • Eiceman, G.A., Leasure, C.S., and Vandiver, V.J. (1986) Negative-ion mobility spectrometry for selected inorganic pollutant gases and gas-mixtures in air. Anal. Chem., 58: 76-80. (Pubitemid 16502281)
    • (1986) Analytical Chemistry , vol.58 , Issue.1 , pp. 76-80
    • Eiceman, G.A.1    Leasure, C.S.2    Vandiver, V.J.3
  • 37
    • 0345876146 scopus 로고    scopus 로고
    • Evaluation of Gas Chromatography Coupled with Ion Mobility Spectrometry for Monitoring Vinyl Chloride and Other Chlorinated and Aromatic Compounds in Air Samples
    • Simpson, G., Klasmeier, M., Hill, H., Atkinson, D., Radolovich, G., Lopez Avila, V., and Jones, T.L. (1996) Evaluation of gas chromatography coupled with ion mobility spectrometry for monitoring vinyl chloride and other chlorinated and aromatic compounds in air samples. J. High. Resolut. Chrom., 19: 301-312. (Pubitemid 126414441)
    • (1996) HRC Journal of High Resolution Chromatography , vol.19 , Issue.6 , pp. 301-312
    • Simpson, G.1    Klasmeier, M.2    Hill, H.3    Atkinson, D.4    Radolovich, G.5    Lopez-Avila, V.6    Jones, T.L.7
  • 38
    • 0034555630 scopus 로고    scopus 로고
    • Monitoring Volatile Organic Compounds in Ambient Air inside and outside Buildings with the Use of a Radio-Frequency-Based Ion-Mobility Analyzer with a Micromachined Drift Tube
    • DOI 10.1002/1520-6521(2000)4:6<297::AID-FACT50>3.0.CO;2-H
    • Eiceman,G.A., Nazarov, E.G., Tadjikov,B., andMiller, R.A. (2000) Monitoring volatile organic compounds in ambient air inside and outside buildings with the use of a radio-frequency-based ion-mobility analyzer with a micromachined drift tube. Field Anal. Chem. Tech., 4: 297-308. (Pubitemid 33213812)
    • (2000) Field Analytical Chemistry and Technology , vol.4 , Issue.6 , pp. 297-308
    • Eiceman, G.A.1    Nazarov, E.G.2    Tadjikov, B.3    Miller, R.A.4
  • 39
    • 33745271749 scopus 로고    scopus 로고
    • Calibration of the volatile organic analyzer for the international pace station second unit
    • Reese, E.S. and Limero, T.F. (2001) Calibration of the volatile organic analyzer for the international pace station second unit. Int. J. Ion. Mobil. Spectrom., 4: 51-53.
    • (2001) Int. J. Ion. Mobil. Spectrom. , vol.4 , pp. 51-53
    • Reese, E.S.1    Limero, T.F.2
  • 40
    • 0025827314 scopus 로고
    • Enzyme-substrate assay for the qualitative detection of microorganisms by ion mobility spectrometry
    • Snyder, A.P., Miller, M., Shoff, D.B., Eiceman, G.A., Blyth, D.A., and Parsons, J.A. (1991) Enzyme-substrate assay for the qualitative detection of microorganisms by ion mobility spectrometry. J. Microbiol. Meth., 14: 21-32.
    • (1991) J. Microbiol. Meth. , vol.14 , pp. 21-32
    • Snyder, A.P.1    Miller, M.2    Shoff, D.B.3    Eiceman, G.A.4    Blyth, D.A.5    Parsons, J.A.6
  • 42
    • 33745236564 scopus 로고    scopus 로고
    • A fundamental introduction to ion mobility mass spectrometry applied to the analysis of biomolecules
    • Verbeck,G.F., Ruotolo, B.T., Sawyer, H.A.,Gillig,K.J., and Russell, D.H. (2002)A fundamental introduction to ion mobility mass spectrometry applied to the analysis of biomolecules. J. Biomol. Tech., 13: 56-61.
    • (2002) J. Biomol. Tech. , vol.13 , pp. 56-61
    • Verbeck, G.F.1    Ruotolo, B.T.2    Sawyer, H.A.3    Gillig, K.J.4    Russell, D.H.5
  • 44
    • 7744232924 scopus 로고    scopus 로고
    • Correlation of mass spectrometry identified bacterial biomarkers from a fielded pyrolysis-gas chromatography-ion mobility spectrometry biodetector with the microbiological gram stain classification scheme
    • DOI 10.1021/ac040099i
    • Snyder, A.P., Dworzanski, J.P., Tripathi, A., Maswadeh, W.M., and Wick, C.H. (2004) Correlation of mass spectrometry identified bacterial biomarkers from a fielded pyrolysis-gas chromatography-ion mobility spectrometry biodetector with the microbiological gram stain classification scheme. Anal. Chem., 76: 6492-6499. (Pubitemid 39461997)
    • (2004) Analytical Chemistry , vol.76 , Issue.21 , pp. 6492-6499
    • Snyder, A.P.1    Dworzanski, J.P.2    Tripathi, A.3    Maswadeh, W.M.4    Wick, C.H.5
  • 45
    • 0002535068 scopus 로고    scopus 로고
    • Detection of the picolinic acid biomarker in bacillus spores using a potentially field-portable pyrolysis-gas chromatography-ion mobility spectrometry system
    • Snyder, A.P., Thornton, S.N., Dworzanski, J.P., and Meuzelaar, H.L.C. (1996) Detection of the picolinic acid biomarker in Bacillus spores using a potentially field-portable pyrolysis gas chromatography ion mobility spectrometry system. Field Anal. Chem. Tech., 1: 49-59. (Pubitemid 126680753)
    • (1996) Field Analytical Chemistry and Technology , vol.1 , Issue.1 , pp. 49-59
    • Peter Snyder, A.1    Thornton, S.N.2    Dworzanski, J.P.3    Meuzelaar, H.L.C.4
  • 49
    • 49049114257 scopus 로고    scopus 로고
    • Micro-plasma: A novel ionisation source for ion mobility spectrometry
    • Vautz,W., Michels, A., and Franzke, J. (2008) Micro-plasma: A novel ionisation source for ion mobility spectrometry. Anal. Bioanal. Chem., 391: 2609-2615.
    • (2008) Anal. Bioanal. Chem. , vol.391 , pp. 2609-2615
    • Vautz, W.1    Michels, A.2    Franzke, J.3
  • 50
    • 77951867484 scopus 로고    scopus 로고
    • Application of a nonradioactive pulsed electron source for ion mobility spectrometry
    • Gunzer, F., Zimmermann, S., and Baether, W. (2010) Application of a nonradioactive pulsed electron source for ion mobility spectrometry. Anal. Chem., 82: 3756-3763.
    • (2010) Anal. Chem. , vol.82 , pp. 3756-3763
    • Gunzer, F.1    Zimmermann, S.2    Baether, W.3
  • 51
    • 77954086744 scopus 로고    scopus 로고
    • A novel non-radioactive electron source for ion mobility spectrometry
    • Gunzer, F., Ulrich, A., and Baether, W. (2010) A novel non-radioactive electron source for ion mobility spectrometry. Int. J. Ion. Mobil. Spectrom., 13: 9-16.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 9-16
    • Gunzer, F.1    Ulrich, A.2    Baether, W.3
  • 52
    • 78649903850 scopus 로고    scopus 로고
    • Investigation of the influence of voltage parameters on decay times in an ion mobility spectrometer with a pulsed non-radioactive electron source
    • Baether, W., Zimmermann, S., and Gunzer, F. (2010) Investigation of the influence of voltage parameters on decay times in an ion mobility spectrometer with a pulsed non-radioactive electron source. Int. J. Ion. Mobil. Spectrom., 13: 95-101.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 95-101
    • Baether, W.1    Zimmermann, S.2    Gunzer, F.3
  • 53
    • 43949141225 scopus 로고    scopus 로고
    • Atmospheric pressure air direct current glow discharge ionization source for ion mobility spectrometry
    • DOI 10.1021/ac800197g
    • Dong, C., Wang, W., and Li, H. (2008) Atmospheric pressure air direct current glow discharge ionization source for ion mobility spectrometry. Anal. Chem., 80: 3925-3930. (Pubitemid 351705903)
    • (2008) Analytical Chemistry , vol.80 , Issue.10 , pp. 3925-3930
    • Dong, C.1    Wang, W.2    Li, H.3
  • 54
    • 70249125804 scopus 로고    scopus 로고
    • Novel chemical ion source for a high-field asymmetric waveform ion mobility spectrometer used under ambient conditions
    • Liu, K., Tang, F., Wang, X.H., Wei, X.Y., and Xiong, J.J. (2009) Novel chemical ion source for a high-field asymmetric waveform ion mobility spectrometer used under ambient conditions. Acta Physico-Chimica Sinica, 25: 1662-1670.
    • (2009) Acta Physico-Chimica Sinica , vol.25 , pp. 1662-1670
    • Liu, K.1    Tang, F.2    Wang, X.H.3    Wei, X.Y.4    Xiong, J.J.5
  • 55
    • 67649716989 scopus 로고    scopus 로고
    • Negative corona discharge ion source under ambient conditions with mini line-cylinder electrodes
    • Liu, K., Tang, F., Wang, X.H., Zhang, L., and Wei, X.Y. (2009) Negative corona discharge ion source under ambient conditions with mini line-cylinder electrodes. Chin. J. Chem. Phys., 22: 107-112.
    • (2009) Chin. J. Chem. Phys. , vol.22 , pp. 107-112
    • Liu, K.1    Tang, F.2    Wang, X.H.3    Zhang, L.4    Wei, X.Y.5
  • 57
    • 67650074661 scopus 로고    scopus 로고
    • Rapid screening of pesticides from fruit surfaces: Preliminary examinations using a laser desorption-differential mobility spectrometry coupling
    • Borsdorf, H., Roetering, S., Nazarov, E., and Weickhardt, C. (2009) Rapid screening of pesticides from fruit surfaces: Preliminary examinations using a laser desorption-differential mobility spectrometry coupling. Int. J. Ion. Mobil. Spectrom., 12: 15-22.
    • (2009) Int. J. Ion. Mobil. Spectrom. , vol.12 , pp. 15-22
    • Borsdorf, H.1    Roetering, S.2    Nazarov, E.3    Weickhardt, C.4
  • 58
    • 35748952851 scopus 로고    scopus 로고
    • Ion mobility spectrometry of gas-phase ions from laser ablation of solids in air at ambient pressure
    • DOI 10.1366/000370207782217671
    • Eiceman, G.A., Young, D., Schmidt, H., Rodriguez, J.E., Baumbach, J.I., Vautz,W., Lake, D.A., and Johnston, M.V. (2007) Ion mobility spectrometry of gas-phase ions from laser ablation of solids in air at ambient pressure. Appl. Spectros., 61: 1076-1083. (Pubitemid 350044218)
    • (2007) Applied Spectroscopy , vol.61 , Issue.10 , pp. 1076-1083
    • Eiceman, G.A.1    Young, D.2    Schmidt, H.3    Rodriguez, J.E.4    Baumbach, J.I.5    Vautz, W.6    Lake, D.A.7    Johnston, M.V.8
  • 60
    • 33846205552 scopus 로고    scopus 로고
    • Kinetic investigations of proton transfer and complex formation reactions by laser ion mobility spectrometry
    • Lohmannsroben, H.-G., Beitz, T., and Laudien, R. (2006) Kinetic investigations of proton transfer and complex formation reactions by laser ion mobility spectrometry. Proc. SPIE, 6377: 637704.
    • (2006) Proc. SPIE , vol.6377 , pp. 637704
    • Lohmannsroben, H.-G.1    Beitz, T.2    Laudien, R.3
  • 61
    • 77955699128 scopus 로고    scopus 로고
    • Application of laser photofragmentation-resonance enhanced multiphoton ionization to ion mobility spectrometry
    • Headrick, J.M., Reichardt, T.A., Settersten, T.B., Bambha, R.P., and Kliner, D.A.V. (2010) Application of laser photofragmentation-resonance enhanced multiphoton ionization to ion mobility spectrometry. Appl. Optic., 49: 2204-2214.
    • (2010) Appl. Optic. , vol.49 , pp. 2204-2214
    • Headrick, J.M.1    Reichardt, T.A.2    Settersten, T.B.3    Bambha, R.P.4    Kliner, D.A.V.5
  • 62
    • 77952047099 scopus 로고    scopus 로고
    • Negative ion formation in laser ion mobility increment spectrometer
    • Kotkovskii, G., Tugaenko, A., and Chistyakov, A. (2010) Negative ion formation in laser ion mobility increment spectrometer. Tech. Phys. Lett., 36: 276-278.
    • (2010) Tech. Phys. Lett. , vol.36 , pp. 276-278
    • Kotkovskii, G.1    Tugaenko, A.2    Chistyakov, A.3
  • 63
    • 0142215354 scopus 로고    scopus 로고
    • Qualitative analysis of trace constituents by ion mobility increment spectrometer
    • Buryakov, I.A. (2003) Qualitative analysis of trace constituents by ion mobility increment spectrometer. Talanta, 61: 369-375.
    • (2003) Talanta , vol.61 , pp. 369-375
    • Buryakov, I.A.1
  • 64
    • 33947714919 scopus 로고    scopus 로고
    • Analysis of tryptic peptides using desorption electrospray ionisation combined with ion mobility spectrometry/mass spectrometry
    • DOI 10.1002/rcm.2941
    • Kaur-Atwal, G., Weston, D.J., Green, P.S., Crosland, S., Bonner, P.L.R., and Creaser, C.S. (2007) Analysis of tryptic peptides using desorption electrospray ionisation combined with ion mobility spectrometry/mass spectrometry. Rapid Comm. Mass Spectrom., 21: 1131-1138. (Pubitemid 46506566)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.7 , pp. 1131-1138
    • Kaur-Atwal, G.1    Weston, D.J.2    Green, P.S.3    Crosland, S.4    Bonner, P.L.R.5    Creaser, C.S.6
  • 65
    • 0028266356 scopus 로고
    • Electrospray ion mobility spectrometry
    • DOI 10.1016/0165-9936(94)87074-8
    • Shumate, C. (1994) Electrospray ion mobility spectrometry. TrAC: Trends in Analytical Chemistry, 13: 104-109. (Pubitemid 24087012)
    • (1994) TrAC - Trends in Analytical Chemistry , vol.13 , Issue.3 , pp. 104-109
    • Shumate, C.1
  • 66
    • 2442704333 scopus 로고    scopus 로고
    • Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection
    • DOI 10.1021/ac0354591
    • Tam, M. and Hill, H.H. (2004) Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection. Anal. Chem., 76: 2741-2747. (Pubitemid 38657698)
    • (2004) Analytical Chemistry , vol.76 , Issue.10 , pp. 2741-2747
    • Tam, M.1    Hill Jr., H.H.2
  • 67
    • 0001015266 scopus 로고
    • Electrospray-ionization ion mobility spectrometry
    • Wittmer, D., Luckenbill, B.K., Hill, H.H., and Chen, Y.H. (1994) Electrospray-ionization ion mobility spectrometry. Anal. Chem., 66: 2348-2355.
    • (1994) Anal. Chem. , vol.66 , pp. 2348-2355
    • Wittmer, D.1    Luckenbill, B.K.2    Hill, H.H.3    Chen, Y.H.4
  • 68
    • 58149528047 scopus 로고    scopus 로고
    • Improved design for high resolution electrospray ionization ion mobility spectrometry
    • Jafari, M.T. (2009) Improved design for high resolution electrospray ionization ion mobility spectrometry. Talanta, 77: 1632-1639.
    • (2009) Talanta , vol.77 , pp. 1632-1639
    • Jafari, M.T.1
  • 69
    • 34247339778 scopus 로고    scopus 로고
    • Design for electrospray ionization-ion mobility spectrometry
    • Khayamian, T. and Jafari, M.T. (2007) Design for electrospray ionization-ion mobility spectrometry. Anal. Chem., 79: 3199-3205.
    • (2007) Anal. Chem. , vol.79 , pp. 3199-3205
    • Khayamian, T.1    Jafari, M.T.2
  • 71
    • 34547164394 scopus 로고    scopus 로고
    • Evaluation of high-field asymmetric waveform ion mobility spectrometry coupled to nanoelectrospray ionization for bioanalysis in drug discovery
    • DOI 10.1002/rcm.3093
    • Hatsis, P., Brockman, A.H., and Wu, J.T. (2007) Evaluation of high-field asymmetric waveform ion mobility spectrometry coupled to nanoelectrospray ionization for bioanalysis in drug discovery. Rapid Comm. Mass Spectrom., 21: 2295-2300. (Pubitemid 47121161)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.14 , pp. 2295-2300
    • Hatsis, P.1    Brockman, A.H.2    Wu, J.-T.3
  • 72
    • 58149139271 scopus 로고    scopus 로고
    • Fundamentals of traveling wave ion mobility spectrometry
    • Shvartsburg, A.A. and Smith, R.D. (2008) Fundamentals of traveling wave ion mobility spectrometry. Anal. Chem., 80: 9689-9699.
    • (2008) Anal. Chem. , vol.80 , pp. 9689-9699
    • Shvartsburg, A.A.1    Smith, R.D.2
  • 73
    • 56549112315 scopus 로고    scopus 로고
    • Evaluation of a new miniaturized ion mobility spectrometer and its coupling to fast gas chromatography multicapillary columns
    • Aguilera-Herrador, E., Cardenas, S., Ruzsanyi, V., Sielemann, S., and Valcarcel, M. (2008) Evaluation of a new miniaturized ion mobility spectrometer and its coupling to fast gas chromatography multicapillary columns. J. Chrom., 1214: 143-150.
    • (2008) J. Chrom. , vol.1214 , pp. 143-150
    • Aguilera-Herrador, E.1    Cardenas, S.2    Ruzsanyi, V.3    Sielemann, S.4    Valcarcel, M.5
  • 74
    • 35448971517 scopus 로고    scopus 로고
    • Performance, resolving power, and radial ion distributions of a prototype nanoelectrospray ionization resistive glass atmospheric pressure ion mobility spectrometer
    • DOI 10.1021/ac071226o
    • Kwasnik, M., Fuhrer, K., Gonin, M., Barbeau, K., and Fernandez, F.M. (2007) Performance, resolving power, and radial ion distributions of a prototype nanoelectrospray ionization resistive glass atmospheric pressure ion mobility spectrometer. Anal. Chem., 79: 7782-7791. (Pubitemid 47622408)
    • (2007) Analytical Chemistry , vol.79 , Issue.20 , pp. 7782-7791
    • Kwasnik, M.1    Fuhrer, K.2    Gonin, M.3    Barbeau, K.4    Fernandez, F.M.5
  • 76
    • 75649145397 scopus 로고    scopus 로고
    • Inverse ion mobility spectrometry
    • Tabrizchi, M. and Jazan, E. (2010) Inverse ion mobility spectrometry. Anal.Chem., 82: 746-750.
    • (2010) Anal.Chem. , vol.82 , pp. 746-750
    • Tabrizchi, M.1    Jazan, E.2
  • 77
    • 77957321662 scopus 로고    scopus 로고
    • Theory for inverse pulsing of the shutter grid in ion mobility spectrometry
    • Spangler,G.E. (2010) Theory for inverse pulsing of the shutter grid in ion mobility spectrometry. Anal. Chem., 82: 8052-8059.
    • (2010) Anal. Chem. , vol.82 , pp. 8052-8059
    • Spangler, G.E.1
  • 80
    • 77957324471 scopus 로고    scopus 로고
    • A scanning frequency mode for ion cyclotron mobility spectrometry
    • Glaskin, R.S., Valentine, S.J., and Clemmer, D.E. (2010) A scanning frequency mode for ion cyclotron mobility spectrometry. Anal. Chem., 82: 8266-8271.
    • (2010) Anal. Chem. , vol.82 , pp. 8266-8271
    • Glaskin, R.S.1    Valentine, S.J.2    Clemmer, D.E.3
  • 81
    • 51549112969 scopus 로고    scopus 로고
    • Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare agents
    • Zimmermann, S., Barth, S., Baether, W.K.M., and Ringer, J. (2008) Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare agents. Anal. Chem., 80: 6671-6676.
    • (2008) Anal. Chem. , vol.80 , pp. 6671-6676
    • Zimmermann, S.1    Barth, S.2    Baether, W.K.M.3    Ringer, J.4
  • 83
    • 77949801007 scopus 로고    scopus 로고
    • High-resolution differential ion mobility separations using helium-rich gases
    • Shvartsburg, A.A., Danielson, W.F., and Smith, R.D. (2010) High-resolution differential ion mobility separations using helium-rich gases. Anal. Chem., 82: 2456-2462.
    • (2010) Anal. Chem. , vol.82 , pp. 2456-2462
    • Shvartsburg, A.A.1    Danielson, W.F.2    Smith, R.D.3
  • 84
    • 77956574893 scopus 로고    scopus 로고
    • High-resolution differential ion mobility separations using planar analyzers at elevated dispersion fields
    • Shvartsburg, A.A., Prior, D.C., Tang, K.Q., and Smith, R.D. (2010) High-resolution differential ion mobility separations using planar analyzers at elevated dispersion fields. Anal. Chem., 82: 7649-7655.
    • (2010) Anal. Chem. , vol.82 , pp. 7649-7655
    • Shvartsburg, A.A.1    Prior, D.C.2    Tang, K.Q.3    Smith, R.D.4
  • 85
    • 68049083696 scopus 로고    scopus 로고
    • Ultrafast differential ion mobility spectrometry at extreme electric fields in multichannel microchips
    • Shvartsburg, A.A., Smith, R.D., Wilks, A., Koehl, A., Ruiz-Alonso, D., and Boyle, B. (2009) Ultrafast differential ion mobility spectrometry at extreme electric fields in multichannel microchips. Anal. Chem., 81: 6489-6495.
    • (2009) Anal. Chem. , vol.81 , pp. 6489-6495
    • Shvartsburg, A.A.1    Smith, R.D.2    Wilks, A.3    Koehl, A.4    Ruiz-Alonso, D.5    Boyle, B.6
  • 86
    • 31544481878 scopus 로고    scopus 로고
    • Pressure effects on resolution in ion mobility spectrometry
    • DOI 10.1016/j.talanta.2005.09.016, PII S0039914005006016
    • Tabrizchi, M. and Rouholahnejad, F. (2006) Pressure effects on resolution in ion mobility spectrometry. Talanta, 69: 87-90. (Pubitemid 43165507)
    • (2006) Talanta , vol.69 , Issue.1 , pp. 87-90
    • Tabrizchi, M.1    Rouholahnejad, F.2
  • 87
    • 33751221650 scopus 로고    scopus 로고
    • Pressure effects in differential mobility spectrometry
    • DOI 10.1021/ac061092z
    • Nazarov, E.G., Coy, S.L., Krylov, E.V.,Miller, R.A., and Eiceman, G.A. (2006) Pressure effects in differential mobility spectrometry. Anal. Chem., 78: 7697-7706. (Pubitemid 44788712)
    • (2006) Analytical Chemistry , vol.78 , Issue.22 , pp. 7697-7706
    • Nazarov, E.G.1    Coy, S.L.2    Krylov, E.V.3    Miller, R.A.4    Eiceman, G.A.5
  • 88
    • 37149049631 scopus 로고    scopus 로고
    • Ion mobility spectrometry detection for gas chromatography
    • DOI 10.1016/j.chroma.2007.10.110, PII S002196730701864X
    • Kanu, A.B. and Hill, H.H., Jr. (2008) Ion mobility spectrometry detection for gas chromatography. J. Chrom., 1177: 12-27. (Pubitemid 50008528)
    • (2008) Journal of Chromatography A , vol.1177 , Issue.1 , pp. 12-27
    • Kanu, A.B.1    Hill Jr., H.H.2
  • 89
    • 63949085990 scopus 로고    scopus 로고
    • A comparison of the ion chemistry for mono-substituted toluenes and anilines by three methods of atmospheric pressure ionization with ion mobility spectrometry
    • Borsdorf, H., Neitsch, K., Eiceman, G.A., and Stone, J.A. (2009) A comparison of the ion chemistry for mono-substituted toluenes and anilines by three methods of atmospheric pressure ionization with ion mobility spectrometry. Talanta, 78: 1464-1475.
    • (2009) Talanta , vol.78 , pp. 1464-1475
    • Borsdorf, H.1    Neitsch, K.2    Eiceman, G.A.3    Stone, J.A.4
  • 90
    • 58149105322 scopus 로고    scopus 로고
    • Temperature effects in differential mobility spectrometry
    • Krylov, E.V., Coy, S.L., and Nazarov, E.G. (2009) Temperature effects in differential mobility spectrometry. Int. J. Mass Spectrom., 279: 119-125.
    • (2009) Int. J. Mass Spectrom. , vol.279 , pp. 119-125
    • Krylov, E.V.1    Coy, S.L.2    Nazarov, E.G.3
  • 92
    • 39949083557 scopus 로고    scopus 로고
    • Optimising cell temperature and dispersion field strength for the screening for putrescine and cadaverine with thermal desorption-gas chromatography-differential mobility spectrometry
    • Awan, M.A., Fleet, I., and Thomas, C.L.P. (2008) Optimising cell temperature and dispersion field strength for the screening for putrescine and cadaverine with thermal desorption-gas chromatography-differential mobility spectrometry. Anal. Chim. Acta, 611: 226-232.
    • (2008) Anal. Chim. Acta , vol.611 , pp. 226-232
    • Awan, M.A.1    Fleet, I.2    Thomas, C.L.P.3
  • 93
    • 33847196443 scopus 로고    scopus 로고
    • Distortion of ion structures by field asymmetric waveform ion mobility spectrometry
    • Shvartsburg, A.A., Li, F.M., Tang, K.Q., and Smith, R.D. (2007) Distortion of ion structures by field asymmetric waveform ion mobility spectrometry. Anal. Chem., 79: 1523-1528.
    • (2007) Anal. Chem. , vol.79 , pp. 1523-1528
    • Shvartsburg, A.A.1    Li, F.M.2    Tang, K.Q.3    Smith, R.D.4
  • 94
    • 54749158150 scopus 로고    scopus 로고
    • Control of ion distortion in field asymmetric waveform ion mobility spectrometry via variation of dispersion field and gas temperature
    • Robinson, E.W., Shvartsburg, A.A., Tang, K., and Smith, R.D. (2008) Control of ion distortion in field asymmetric waveform ion mobility spectrometry via variation of dispersion field and gas temperature. Anal. Chem., 80: 7508-7515.
    • (2008) Anal. Chem. , vol.80 , pp. 7508-7515
    • Robinson, E.W.1    Shvartsburg, A.A.2    Tang, K.3    Smith, R.D.4
  • 95
    • 60149101111 scopus 로고    scopus 로고
    • Trace level impurity method development with high-field asymmetric waveform ion mobility spectrometry: Systematic study of factors affecting the performance
    • Champarnaud, E., Laures, A.M.F., Borman, P.J., Chatfield, M.J., Kapron, J.T., Harrison, M., and Wolff, J.C. (2009) Trace level impurity method development with high-field asymmetric waveform ion mobility spectrometry: Systematic study of factors affecting the performance. Rapid Comm. Mass Spectrom., 23: 181-193.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 181-193
    • Champarnaud, E.1    Laures, A.M.F.2    Borman, P.J.3    Chatfield, M.J.4    Kapron, J.T.5    Harrison, M.6    Wolff, J.C.7
  • 96
    • 77149134996 scopus 로고    scopus 로고
    • Control of chemical effects in the separation process of a differential mobility mass spectrometer system
    • Schneider, B.B., Covey, T.R., Coy, S.L., Krylov, E.V., and Nazarov, E.G. (2010) Control of chemical effects in the separation process of a differential mobility mass spectrometer system. Eur. J. Mass Spectrom., 16: 57-71.
    • (2010) Eur. J. Mass Spectrom. , vol.16 , pp. 57-71
    • Schneider, B.B.1    Covey, T.R.2    Coy, S.L.3    Krylov, E.V.4    Nazarov, E.G.5
  • 97
    • 77957320584 scopus 로고    scopus 로고
    • Isotopic effect on ion mobility and separation of lsotopomers by high-field ion mobility spectrometry
    • Shvartsburg, A.A., Clemmer, D.E., and Smith, R.D. (2010) Isotopic effect on ion mobility and separation of lsotopomers by high-field ion mobility spectrometry. Anal. Chem., 82: 8047-8051.
    • (2010) Anal. Chem. , vol.82 , pp. 8047-8051
    • Shvartsburg, A.A.1    Clemmer, D.E.2    Smith, R.D.3
  • 98
    • 67650714718 scopus 로고    scopus 로고
    • Treatise on the measurement of molecular masses with ion mobility spectrometry
    • Valentine, S.J. and Clemmer, D.E. (2009) Treatise on the measurement of molecular masses with ion mobility spectrometry. Anal. Chem., 81: 5876-5880.
    • (2009) Anal. Chem. , vol.81 , pp. 5876-5880
    • Valentine, S.J.1    Clemmer, D.E.2
  • 99
    • 78649907465 scopus 로고    scopus 로고
    • Electric field dependence of ion mobilities of aromatic compounds with different ionic mass and different functional groups
    • Borsdorf, H. and Mayer, T. (2010) Electric field dependence of ion mobilities of aromatic compounds with different ionic mass and different functional groups. Int. J. Ion. Mobil. Spectrom., 13: 103-108.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 103-108
    • Borsdorf, H.1    Mayer, T.2
  • 100
    • 33847100416 scopus 로고    scopus 로고
    • Time-of-flight ion mobility spectrometry and differential mobility spectrometry: A comparative study of their efficiency in the analysis of halogenated compounds
    • DOI 10.1016/j.talanta.2006.08.017, PII S0039914006005832
    • Borsdorf, H., Nazarov, E.G., and Miller, R.A. (2007) Time-of-flight ion mobility spectrometry and differential mobility spectrometry: A comparative study of their efficiency in the analysis of halogenated compounds. Talanta, 71: 1804-1812. (Pubitemid 46282862)
    • (2007) Talanta , vol.71 , Issue.4 , pp. 1804-1812
    • Borsdorf, H.1    Nazarov, E.G.2    Miller, R.A.3
  • 101
    • 34247165816 scopus 로고    scopus 로고
    • Enantiomer separation of amino acids by complexation with chiral reference compounds and high-field asymmetric waveform ion mobility spectrometry: Preliminary results and possible limitations
    • DOI 10.1021/ac0618627
    • Mie, A., Jornten-Karlsson, M., Axelsson, B.O., Ray, A., and Reimann, C.T. (2007) Enantiomer separation of amino acids by complexation with chiral reference compounds and high-field asymmetric waveform ion mobility spectrometry: Preliminary results and possible limitations. Anal. Chem., 79: 2850-2858. (Pubitemid 46595640)
    • (2007) Analytical Chemistry , vol.79 , Issue.7 , pp. 2850-2858
    • Mie, A.1    Jornten-Karlsson, M.2    Axelsson, B.-O.3    Ray, A.4    Reimann, C.T.5
  • 102
    • 78649903775 scopus 로고    scopus 로고
    • Influence of structural features of isomeric hydrocarbons on ion formation at atmospheric pressure
    • Borsdorf, H. (2008) Influence of structural features of isomeric hydrocarbons on ion formation at atmospheric pressure. Int. J. Ion. Mobil. Spectrom., 11: 27-33.
    • (2008) Int. J. Ion. Mobil. Spectrom. , vol.11 , pp. 27-33
    • Borsdorf, H.1
  • 103
    • 78650175910 scopus 로고    scopus 로고
    • Response of halogenated compounds in ion mobility spectrometry depending on their structural features
    • Borsdorf, H. and Mayer, T. (2011) Response of halogenated compounds in ion mobility spectrometry depending on their structural features. Talanta, 83: 815-822.
    • (2011) Talanta , vol.83 , pp. 815-822
    • Borsdorf, H.1    Mayer, T.2
  • 104
    • 79951509609 scopus 로고    scopus 로고
    • The effect of ion molecule reactions on peaks in ion mobility spectrometry
    • Tabrizchi, M. andKhezri, E. (2008) The effect of ion molecule reactions on peaks in ion mobility spectrometry. Int. J. Ion. Mobil. Spectrom., 11: 19-25.
    • (2008) Int. J. Ion. Mobil. Spectrom. , vol.11 , pp. 19-25
    • Tabrizchi, M.1    Khezri, E.2
  • 106
    • 67650065413 scopus 로고    scopus 로고
    • Mechanisms for negative reactant ion formation in an atmospheric pressure corona discharge
    • Ewing, R. and Waltman, M. (2009) Mechanisms for negative reactant ion formation in an atmospheric pressure corona discharge. Int. J. Ion. Mobil. Spectrom., 12: 65-72.
    • (2009) Int. J. Ion. Mobil. Spectrom. , vol.12 , pp. 65-72
    • Ewing, R.1    Waltman, M.2
  • 108
    • 50149120507 scopus 로고    scopus 로고
    • Ion mobility spectrometers with doped gases
    • Puton, J., Nousiainen, M., and Sillanpaa, M. (2008) Ion mobility spectrometers with doped gases. Talanta, 76: 978-987.
    • (2008) Talanta , vol.76 , pp. 978-987
    • Puton, J.1    Nousiainen, M.2    Sillanpaa, M.3
  • 109
    • 42449096448 scopus 로고    scopus 로고
    • The use of dopants in high field asymmetric waveform spectrometry
    • DOI 10.1039/b801457b
    • Ross, S.K.,McDonald, G., and Marchant, S. (2008) The use of dopants in high field asymmetric waveform spectrometry. Analyst, 133: 602-607. (Pubitemid 351572833)
    • (2008) Analyst , vol.133 , Issue.5 , pp. 602-607
    • Ross, S.K.1    McDonald, G.2    Marchant, S.3
  • 110
    • 0242291929 scopus 로고    scopus 로고
    • Atmospheric pressure photoionization mechanisms. 2. The case of benzene and toluene
    • Tubaro,M., Marotta,E., Seraglia,R., andTraldi, P. (2003) Atmospheric pressure photoionization mechanisms. 2. The case of benzene and toluene. RapidComm. Mass Spectrom., 17: 2423-2429. (Pubitemid 37356318)
    • (2003) Rapid Communications in Mass Spectrometry , vol.17 , Issue.21 , pp. 2423-2429
    • Tubaro, M.1    Marotta, E.2    Seraglia, R.3    Traldi, P.4
  • 111
    • 33745728428 scopus 로고    scopus 로고
    • Miniature differential mobility spectrometry using atmospheric pressure photoionization
    • Nazarov, E.G., Miller, R.A., Eiceman, G.A., and Stone, J.A. (2006) Miniature differential mobility spectrometry using atmospheric pressure photoionization. Anal. Chem., 78: 4553-4563.
    • (2006) Anal. Chem. , vol.78 , pp. 4553-4563
    • Nazarov, E.G.1    Miller, R.A.2    Eiceman, G.A.3    Stone, J.A.4
  • 112
    • 4444309530 scopus 로고    scopus 로고
    • Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas
    • DOI 10.1021/ac035502k
    • Eiceman, G.A., Krylov, E.V., Nazarov, E.G., and Miller, R.A. (2004) Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas. Anal. Chem., 76: 4937-4944. (Pubitemid 39180317)
    • (2004) Analytical Chemistry , vol.76 , Issue.17 , pp. 4937-4944
    • Eiceman, G.A.1    Krylov, E.V.2    Krylova, N.S.3    Nazarov, E.G.4    Miller, R.A.5
  • 113
    • 34247340550 scopus 로고    scopus 로고
    • Mobility Resolution and Mass Analysis of Ions from Ammonia and Hydrazine Complexes with Ketones Formed in Air at Ambient Pressure
    • DOI 10.1016/j.jasms.2007.01.014, PII S1044030507000852
    • Bollan, H.R., Stone, J.A., Brokenshire, J.L.,Rodriguez, J.E., and Eiceman,G.A. (2007) Mobility resolution and mass analysis of ions from ammonia and hydrazine complexes with ketones formed in air at ambient pressure. J. Am. Soc. Mass Spectrom., 18: 940-951. (Pubitemid 46629028)
    • (2007) Journal of the American Society for Mass Spectrometry , vol.18 , Issue.5 , pp. 940-951
    • Bollan, H.R.1    Stone, J.A.2    Brokenshire, J.L.3    Rodriguez, J.E.4    Eiceman, G.A.5
  • 114
    • 77955228390 scopus 로고    scopus 로고
    • Effect of dopants on the analysis of pesticides by means of differential mobility spectrometry with atmospheric pressure photoionization
    • Roetering, S., Nazarov, E., Borsdorf, H., and Weickhardt, C. (2010) Effect of dopants on the analysis of pesticides by means of differential mobility spectrometry with atmospheric pressure photoionization. Int. J. Ion. Mobil. Spectrom., 13: 47-54.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 47-54
    • Roetering, S.1    Nazarov, E.2    Borsdorf, H.3    Weickhardt, C.4
  • 115
    • 39649091389 scopus 로고    scopus 로고
    • Determination of aflatoxins B1 and B2 using ion mobility spectrometry
    • Sheibani, A., Tabrizchi, M., and Ghaziaskar, H.S. (2008) Determination of aflatoxins B1 and B2 using ion mobility spectrometry. Talanta, 75: 233-238.
    • (2008) Talanta , vol.75 , pp. 233-238
    • Sheibani, A.1    Tabrizchi, M.2    Ghaziaskar, H.S.3
  • 116
    • 33748205878 scopus 로고    scopus 로고
    • Atmospheric ammonia measurement with an ion mobility spectrometer
    • DOI 10.1016/j.atmosenv.2006.05.018, PII S1352231006004997
    • Myles, L., Meyers, T.P., and Robinson, L. (2006) Atmospheric ammonia measurement with an ion mobility spectrometer. Atmos. Environ., 40: 5745-5752. (Pubitemid 44311061)
    • (2006) Atmospheric Environment , vol.40 , Issue.30 , pp. 5745-5752
    • Myles, L.1    Meyers, T.P.2    Robinson, L.3
  • 117
    • 55349094326 scopus 로고    scopus 로고
    • Dopant-enhanced atmospheric pressure glow discharge ionization source for ion mobility spectrometry
    • Dong, C., Wang, L., Wang, W., Hou, K., and Li, H. (2008) Dopant-enhanced atmospheric pressure glow discharge ionization source for ion mobility spectrometry. Rev. Sci. Instrum., 79: 104101.
    • (2008) Rev. Sci. Instrum. , vol.79 , pp. 104101
    • Dong, C.1    Wang, L.2    Wang, W.3    Hou, K.4    Li, H.5
  • 118
    • 77749302232 scopus 로고    scopus 로고
    • Chemical effects in the separation process of a differential mobility/mass spectrometer system
    • Schneider, B.B., Covey, T.R., Coy, S.L., Krylov, E.V., and Nazarov, E.G. (2010) Chemical effects in the separation process of a differential mobility/mass spectrometer system. Anal. Chem., 82: 1867-1880.
    • (2010) Anal. Chem. , vol.82 , pp. 1867-1880
    • Schneider, B.B.1    Covey, T.R.2    Coy, S.L.3    Krylov, E.V.4    Nazarov, E.G.5
  • 119
    • 33746809833 scopus 로고    scopus 로고
    • Rapid separation and quantitative analysis of peptides using a new nanoelectrospray-differential mobility spectrometer-mass spectrometer system
    • DOI 10.1021/ac060003f
    • Levin, D.S.,Miller, R.A., Nazarov, E.G., andVouros, P. (2006) Rapid separation and quantitative analysis of peptides using a new nanoelectrospray-differential mobility spectrometer-mass spectrometer system. Anal. Chem., 78: 5443-5452. (Pubitemid 44182363)
    • (2006) Analytical Chemistry , vol.78 , Issue.15 , pp. 5443-5452
    • Levin, D.S.1    Miller, R.A.2    Nazarov, E.G.3    Vouros, P.4
  • 120
    • 33847054648 scopus 로고    scopus 로고
    • Using a Nanoelectrospray-Differential Mobility Spectrometer-Mass Spectrometer System for the Analysis of Oligosaccharides with Solvent Selected Control Over ESI Aggregate Ion Formation
    • DOI 10.1016/j.jasms.2006.10.008, PII S1044030506009548
    • Levin, D.S., Vouros, P., Miller, R.A., and Nazarov, E.G. (2007) Using a nanoelectrospray- differential mobility spectrometer-mass spectrometer system for the analysis of oligosaccharides with solvent selected control over ESI aggregate ion formation. J. Am. Soc.Mass Spectrom., 18: 502-511. (Pubitemid 46274383)
    • (2007) Journal of the American Society for Mass Spectrometry , vol.18 , Issue.3 , pp. 502-511
    • Levin, D.S.1    Vouros, P.2    Miller, R.A.3    Nazarov, E.G.4
  • 121
    • 40849084888 scopus 로고    scopus 로고
    • Sample-introduction systems coupled to ion-mobility spectrometry equipment for determining compounds present in gaseous, liquid and solid samples
    • Arce, L., Menendez, M., Garrido-Delgado, R., and Valcarcel, M. (2008) Sample-introduction systems coupled to ion-mobility spectrometry equipment for determining compounds present in gaseous, liquid and solid samples. TrAC: Trends in Analytical Chemistry, 27: 139-150.
    • (2008) TrAC: Trends in Analytical Chemistry , vol.27 , pp. 139-150
    • Arce, L.1    Menendez, M.2    Garrido-Delgado, R.3    Valcarcel, M.4
  • 122
    • 50149094027 scopus 로고    scopus 로고
    • Molecularly imprinted polymer as a solid phase extractor in flow analysis
    • Dias, A.C.B., Figueiredo, E.C., Grassi, V., Zagatto, E.A.G., and Arruda, M.A.Z. (2008) Molecularly imprinted polymer as a solid phase extractor in flow analysis. Talanta, 76: 988-996.
    • (2008) Talanta , vol.76 , pp. 988-996
    • Dias, A.C.B.1    Figueiredo, E.C.2    Grassi, V.3    Zagatto, E.A.G.4    Arruda, M.A.Z.5
  • 123
    • 0032977152 scopus 로고    scopus 로고
    • Polymer- and template-related factors influencing the efficiency in molecularly imprinted solid-phase extractions
    • DOI 10.1016/S0165-9936(98)00117-4, PII S0165993698001174
    • Sellergren, B. (1999) Polymer- and template-related factors influencing the efficiency in molecularly imprinted solid-phase extractions. TrAC: Trends in Analytical Chemistry, 18: 164-174. (Pubitemid 29117173)
    • (1999) TrAC - Trends in Analytical Chemistry , vol.18 , Issue.3 , pp. 164-174
    • Sellergren, B.1
  • 124
    • 66149122638 scopus 로고    scopus 로고
    • Ion mobility spectrometry as a detector for molecular imprinted polymer separation and metronidazole determination in pharmaceutical and human serum samples
    • Jafari, M.T., Rezaei, B., and Zaker, B. (2009) Ion mobility spectrometry as a detector for molecular imprinted polymer separation and metronidazole determination in pharmaceutical and human serum samples. Anal. Chem., 81: 3585-3591.
    • (2009) Anal. Chem. , vol.81 , pp. 3585-3591
    • Jafari, M.T.1    Rezaei, B.2    Zaker, B.3
  • 125
    • 33746378629 scopus 로고    scopus 로고
    • Recent developments in SPME for on-site analysis and monitoring
    • DOI 10.1016/j.trac.2006.05.005, PII S0165993606001154
    • Ouyang, G. and Pawliszyn, J. (2006) Recent developments in SPME for on-site analysis and monitoring. TrAC: Trends in Analytical Chemistry, 25: 692-703. (Pubitemid 44109898)
    • (2006) TrAC - Trends in Analytical Chemistry , vol.25 , Issue.7 , pp. 692-703
    • Ouyang, G.1    Pawliszyn, J.2
  • 126
    • 52449110482 scopus 로고    scopus 로고
    • Headspace sampling and detection of cocaine, MDMA, and marijuana via volatile markers in the presence of potential interferences by solid phase microextraction-ion mobility spectrometry (SPME-IMS)
    • Lai, H., Corbin, I., and Almirall, J.R. (2008) Headspace sampling and detection of cocaine, MDMA, and marijuana via volatile markers in the presence of potential interferences by solid phase microextraction-ion mobility spectrometry (SPME-IMS). Anal. Bioanal. Chem., 392: 105-113.
    • (2008) Anal. Bioanal. Chem. , vol.392 , pp. 105-113
    • Lai, H.1    Corbin, I.2    Almirall, J.R.3
  • 127
    • 39549121292 scopus 로고    scopus 로고
    • Analysis of volatile components of drugs and explosives by solid phase microextraction-ion mobility spectrometry
    • DOI 10.1002/jssc.200700292
    • Lai, H., Guerra, P., Joshi, M., and Almirall, J.R. (2008) Analysis of volatile components of drugs and explosives by solid phase microextraction-ion mobility spectrometry. J. Separ. Sci., 31: 402-412. (Pubitemid 351279418)
    • (2008) Journal of Separation Science , vol.31 , Issue.2 , pp. 402-412
    • Lai, H.1    Guerra, P.2    Joshi, M.3    Almirall, J.R.4
  • 128
    • 33845325340 scopus 로고    scopus 로고
    • The coupling of solid-phase microextraction/surface enhanced laser desorption/ionization to ion mobility spectrometry for drug analysis
    • DOI 10.1016/j.aca.2006.08.049, PII S0003267006018241
    • Wang, Y., Nacson, S., and Pawliszyn, J. (2007) The coupling of solid-phase microextraction/surface enhanced laser desorption/ionization to ion mobility spectrometry for drug analysis. Anal. Chim. Acta, 582: 50-54. (Pubitemid 44880900)
    • (2007) Analytica Chimica Acta , vol.582 , Issue.1 , pp. 50-54
    • Wang, Y.1    Nacson, S.2    Pawliszyn, J.3
  • 129
    • 51549121779 scopus 로고    scopus 로고
    • Analysis of the volatile chemical markers of explosives using novel solid phase microextraction coupled to ion mobility spectrometry
    • Guerra, P., Lai, H., and Almirall, J.R. (2008) Analysis of the volatile chemical markers of explosives using novel solid phase microextraction coupled to ion mobility spectrometry. J. Separ. Sci., 31: 2891-2898.
    • (2008) J. Separ. Sci. , vol.31 , pp. 2891-2898
    • Guerra, P.1    Lai, H.2    Almirall, J.R.3
  • 130
    • 77950406183 scopus 로고    scopus 로고
    • Dynamic planar solid phase microextraction-ion mobility spectrometry for rapid field air sampling and analysis of illicit drugs and explosives
    • Guerra-Diaz, P., Gura, S., and Almirall, J.R. (2010) Dynamic planar solid phase microextraction-ion mobility spectrometry for rapid field air sampling and analysis of illicit drugs and explosives. Anal. Chem., 82: 2826-2835.
    • (2010) Anal. Chem. , vol.82 , pp. 2826-2835
    • Guerra-Diaz, P.1    Gura, S.2    Almirall, J.R.3
  • 131
    • 77950395901 scopus 로고    scopus 로고
    • Enhancement in sample collection for the detection of MDM using a novel planar SPME (PSPME) device coupled to ion mobility spectrometry (IMS)
    • Gura, S., Guerra-Diaz, P., Lai, H., and Almirall, J.R. (2009) Enhancement in sample collection for the detection of MDM using a novel planar SPME (PSPME) device coupled to ion mobility spectrometry (IMS). Drug Test. Anal., 1: 355-362.
    • (2009) Drug Test. Anal. , vol.1 , pp. 355-362
    • Gura, S.1    Guerra-Diaz, P.2    Lai, H.3    Almirall, J.R.4
  • 132
    • 67449168022 scopus 로고    scopus 로고
    • Ionic liquid-based single drop microextraction and room-temperature gas chromatography for on-site ion mobility spectrometric analysis
    • Aguilera-Herrador, E., Lucena, R., Cardenas, S., and Valcarcel, M. (2009) Ionic liquid-based single drop microextraction and room-temperature gas chromatography for on-site ion mobility spectrometric analysis. J. Chrom., 1216: 5580-5587.
    • (2009) J. Chrom. , vol.1216 , pp. 5580-5587
    • Aguilera-Herrador, E.1    Lucena, R.2    Cardenas, S.3    Valcarcel, M.4
  • 133
    • 77952485869 scopus 로고    scopus 로고
    • Membrane-extraction ion mobility spectrometry for in situ detection of chlorinated hydrocarbons in water
    • Du, Y.Z., Zhang, W., Whitten, W., Li, H.Y., Watson, D.B., and Xu, J. (2010) Membrane-extraction ion mobility spectrometry for in situ detection of chlorinated hydrocarbons in water. Anal. Chem., 82: 4089-4096.
    • (2010) Anal. Chem. , vol.82 , pp. 4089-4096
    • Du, Y.Z.1    Zhang, W.2    Whitten, W.3    Li, H.Y.4    Watson, D.B.5    Xu, J.6
  • 134
    • 77955227844 scopus 로고    scopus 로고
    • Transport modeling of membrane extraction of chlorinated hydrocarbon from water for ion mobility spectrometry
    • Zhang, W., Du, Y., Feng, Z., and Xu, J. (2010) Transport modeling of membrane extraction of chlorinated hydrocarbon from water for ion mobility spectrometry. Int. J. Ion. Mobil. Spectrom., 13: 65-71.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 65-71
    • Zhang, W.1    Du, Y.2    Feng, Z.3    Xu, J.4
  • 135
    • 73949150267 scopus 로고    scopus 로고
    • Selective sampling with direct ion mobility spectrometric detection for explosives analysis
    • Harvey, S., Ewing, R., and Waltman, M. (2009) Selective sampling with direct ion mobility spectrometric detection for explosives analysis. Int. J. Ion. Mobil. Spectrom., 12: 115-121.
    • (2009) Int. J. Ion. Mobil. Spectrom. , vol.12 , pp. 115-121
    • Harvey, S.1    Ewing, R.2    Waltman, M.3
  • 137
    • 33846069140 scopus 로고    scopus 로고
    • A small subsurface ion mobility spectrometer sensor for detecting environmental soil-gas contaminants
    • DOI 10.1039/b610493b
    • Kanu, A.B., Hill, H.H., Gribb, M.M., andWalters, R.N. (2007) A small subsurface ion mobility spectrometer sensor for detecting environmental soil-gas contaminants. J. Environ. Monit., 9: 51-60. (Pubitemid 46072467)
    • (2007) Journal of Environmental Monitoring , vol.9 , Issue.1 , pp. 51-60
    • Kanu, A.B.1    Hill Jr., H.H.2    Gribb, M.M.3    Walters, R.N.4
  • 138
    • 56949089063 scopus 로고    scopus 로고
    • Direct determination of volatile analytes from solid samples by UV-ion mobility spectrometry
    • Menendez, M., Garrido-Delgado, R., Arce, L., and Valcarcel,M. (2008) Direct determination of volatile analytes from solid samples by UV-ion mobility spectrometry. J. Chrom., 1215: 8-14.
    • (2008) J. Chrom. , vol.1215 , pp. 8-14
    • Menendez, M.1    Garrido-Delgado, R.2    Arce, L.3    Valcarcel, M.4
  • 139
    • 78650169091 scopus 로고    scopus 로고
    • Ion mobility spectrometry: A valuable tool for kinetic studies in enzymology
    • Armenta, S. and Blanco, M. (2011) Ion mobility spectrometry: A valuable tool for kinetic studies in enzymology. Anal. Chim. Acta, 685: 1-8.
    • (2011) Anal. Chim. Acta , vol.685 , pp. 1-8
    • Armenta, S.1    Blanco, M.2
  • 140
    • 78650173218 scopus 로고    scopus 로고
    • Selective pretreatment and determination of phenazopyridine using an imprinted polymer-electrospray ionization ion mobility spectrometry system
    • Rezaei, B., Jafari,M.T., and Rahmanian, O. (2011) Selective pretreatment and determination of phenazopyridine using an imprinted polymer-electrospray ionization ion mobility spectrometry system. Talanta, 83: 765-769.
    • (2011) Talanta , vol.83 , pp. 765-769
    • Rezaei, B.1    Jafari, M.T.2    Rahmanian, O.3
  • 141
    • 67649361346 scopus 로고    scopus 로고
    • Selective separation and determination of primidone in pharmaceutical and human serum samples using molecular imprinted polymer-electrospray ionization ion mobility spectrometry (MIP-ESI-IMS)
    • Rezaei, B., Jafari, M.T., and Khademi, R. (2009) Selective separation and determination of primidone in pharmaceutical and human serum samples using molecular imprinted polymer-electrospray ionization ion mobility spectrometry (MIP-ESI-IMS). Talanta, 79: 669-675.
    • (2009) Talanta , vol.79 , pp. 669-675
    • Rezaei, B.1    Jafari, M.T.2    Khademi, R.3
  • 143
    • 75749092642 scopus 로고    scopus 로고
    • Differential ion mobility separations of peptides with resolving power exceeding 50
    • Shvartsburg, A.A., Tang, K.Q., and Smith, R.D. (2010) Differential ion mobility separations of peptides with resolving power exceeding 50. Anal. Chem., 82: 32-35.
    • (2010) Anal. Chem. , vol.82 , pp. 32-35
    • Shvartsburg, A.A.1    Tang, K.Q.2    Smith, R.D.3
  • 144
    • 67650901565 scopus 로고    scopus 로고
    • Validated quantitation method for a peptide in rat serum using liquid chromatography/high-field asymmetric waveform ion mobility spectrometry
    • Klaassen, T., Szwandt, S., Kapron, J.T., and Roemer, A. (2009) Validated quantitation method for a peptide in rat serum using liquid chromatography/high- field asymmetric waveform ion mobility spectrometry. Rapid Comm. Mass Spectrom., 23: 2301-2306.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 2301-2306
    • Klaassen, T.1    Szwandt, S.2    Kapron, J.T.3    Roemer, A.4
  • 145
    • 77957292542 scopus 로고    scopus 로고
    • Separation of peptide isomers with variant modified sites by high-resolution differential ion mobility spectrometry
    • Shvartsburg, A.A., Creese, A.J., Smith, R.D., and Cooper, H.J. (2010) Separation of peptide isomers with variant modified sites by high-resolution differential ion mobility spectrometry. Anal. Chem., 82: 8327-8334.
    • (2010) Anal. Chem. , vol.82 , pp. 8327-8334
    • Shvartsburg, A.A.1    Creese, A.J.2    Smith, R.D.3    Cooper, H.J.4
  • 146
    • 49449092502 scopus 로고    scopus 로고
    • Nanoelectrospray ion mobility spectrometry online with inductively coupled plasma-mass spectrometry for sizing large proteins, DNA, and nanoparticles
    • Carazzone,C., Rami,R., and Pergantis, S.A. (2008) Nanoelectrospray ion mobility spectrometry online with inductively coupled plasma-mass spectrometry for sizing large proteins, DNA, and nanoparticles. Anal. Chem., 80: 5812-5818.
    • (2008) Anal. Chem. , vol.80 , pp. 5812-5818
    • Carazzone, C.1    Rami, R.2    Pergantis, S.A.3
  • 147
    • 77955984379 scopus 로고    scopus 로고
    • Ion mobility spectrometry in scientific literature and in the International Journal for Ion Mobility Spectrometry (1998-2007)
    • Baumbach, J. (2008) Ion mobility spectrometry in scientific literature and in the International Journal for Ion Mobility Spectrometry (1998-2007). Int. J. Ion. Mobil. Spectrom., 11: 3-11.
    • (2008) Int. J. Ion. Mobil. Spectrom. , vol.11 , pp. 3-11
    • Baumbach, J.1
  • 149
    • 78649908201 scopus 로고    scopus 로고
    • Software tool for coupling chromatographic total ion current dependencies of GC/MSD and MCC/IMS
    • Bunkowski, A. (2010) Software tool for coupling chromatographic total ion current dependencies of GC/MSD and MCC/IMS. Int. J. Ion. Mobil. Spectrom., 13: 169-175.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 169-175
    • Bunkowski, A.1
  • 151
    • 39149126316 scopus 로고    scopus 로고
    • Rapid preseparation of interferences for ion mobility spectrometry
    • Kanu, A.B.,Wu, C., and Hill, H.H. (2008) Rapid preseparation of interferences for ion mobility spectrometry. Anal. Chim. Acta, 610: 125-134.
    • (2008) Anal. Chim. Acta , vol.610 , pp. 125-134
    • Kanu, A.B.1    Wu, C.2    Hill, H.H.3
  • 152
    • 58149469493 scopus 로고    scopus 로고
    • Limits of separation of a multi-capillary column with mixtures of volatile organic compounds for a flame ionization detector and a differential mobility detector
    • Eiceman, G.A. and Feng, Y. (2009) Limits of separation of a multi-capillary column with mixtures of volatile organic compounds for a flame ionization detector and a differential mobility detector. J. Chrom., 1216: 985-993.
    • (2009) J. Chrom. , vol.1216 , pp. 985-993
    • Eiceman, G.A.1    Feng, Y.2
  • 153
    • 35948960729 scopus 로고    scopus 로고
    • Increasing analytical space in gas chromatography-differential mobility spectrometry with dispersion field amplitude programming
    • DOI 10.1016/j.chroma.2007.09.082, PII S0021967307016251
    • Basanta, M., Singh, D., Fowler, S., Wilson, I., Dennis, R., and Thomas, C.L. (2007) Increasing analytical space in gas chromatography-differential mobility spectrometry with dispersion field amplitude programming. J. Chrom., 1173: 129-138. (Pubitemid 350064374)
    • (2007) Journal of Chromatography A , vol.1173 , Issue.1-2 , pp. 129-138
    • Basanta, M.1    Singh, D.2    Fowler, S.3    Wilson, I.4    Dennis, R.5    Thomas, C.L.P.6
  • 154
    • 0028855096 scopus 로고
    • Naked protein conformations - Cytochrome-c in the gas-phase
    • Clemmer, D.E., Hudgins, R.R., and Jarrold, M.F. (1995) Naked protein conformations - Cytochrome-c in the gas-phase. J. Am. Chem. Soc., 117: 10141-10142.
    • (1995) J. Am. Chem. Soc. , vol.117 , pp. 10141-10142
    • Clemmer, D.E.1    Hudgins, R.R.2    Jarrold, M.F.3
  • 156
    • 77950664005 scopus 로고    scopus 로고
    • Artificial neural networks for the prediction of peptide drift time in ion mobility mass spectrometry
    • Wang, B., Valentine, S., Plasencia, M., Raghuraman, S., and Zhang, X. (2010) Artificial neural networks for the prediction of peptide drift time in ion mobility mass spectrometry. BMC Bioinformatics, 11: 182.
    • (2010) BMC Bioinformatics , vol.11 , pp. 182
    • Wang, B.1    Valentine, S.2    Plasencia, M.3    Raghuraman, S.4    Zhang, X.5
  • 158
    • 78049505292 scopus 로고    scopus 로고
    • Collision cross-section determination and tandem mass spectrometric analysis of isomeric carotenoids using electrospray ion mobility time-of-flight mass spectrometry
    • Dong, L.L., Shion, H., Davis, R.G., Terry-Penak, B., Castro-Perez, J., and van Breemen, R.B. (2010) Collision cross-section determination and tandem mass spectrometric analysis of isomeric carotenoids using electrospray ion mobility time-of-flight mass spectrometry. Anal. Chem., 82: 9014-9021.
    • (2010) Anal. Chem. , vol.82 , pp. 9014-9021
    • Dong, L.L.1    Shion, H.2    Davis, R.G.3    Terry-Penak, B.4    Castro-Perez, J.5    Van Breemen, R.B.6
  • 160
    • 57349166293 scopus 로고    scopus 로고
    • Characterization of branching in aramid polymers studied by MALDI-ion mobility/mass spectrometry
    • Gies, A.P., Kliman,M., McLean, J.A., and Hercules, D.M. (2008) Characterization of branching in aramid polymers studied by MALDI-ion mobility/mass spectrometry. Macromolecules, 41: 8299-8301.
    • (2008) Macromolecules , vol.41 , pp. 8299-8301
    • Gies, A.P.1    Kliman, M.2    McLean, J.A.3    Hercules, D.M.4
  • 161
    • 77951081386 scopus 로고    scopus 로고
    • Elongated oligomers in beta(2)- microglobulin amyloid assembly revealed by ion mobility spectrometry-mass spectrometry
    • Smith, D.P., Radford, S.E., and Ashcroft, A.E. (2010) Elongated oligomers in beta(2)- microglobulin amyloid assembly revealed by ion mobility spectrometry-mass spectrometry. Proc. Nat. Acad. Sci. USA, 107: 6794-6798.
    • (2010) Proc. Nat. Acad. Sci. USA , vol.107 , pp. 6794-6798
    • Smith, D.P.1    Radford, S.E.2    Ashcroft, A.E.3
  • 162
    • 65549084303 scopus 로고    scopus 로고
    • Isomer separation and gas-phase configurations of organoruthenium anticancer complexes: Ion mobility mass spectrometry and modeling
    • Williams, J.P., Bugarcic, T., Habtemariam, A., Giles, K., Campuzano, I., Rodger, P.M., and Sadler, P.J. (2009) Isomer separation and gas-phase configurations of organoruthenium anticancer complexes: Ion mobility mass spectrometry and modeling. J. Am. Soc. Mass Spectrom., 20: 1119-1122.
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , pp. 1119-1122
    • Williams, J.P.1    Bugarcic, T.2    Habtemariam, A.3    Giles, K.4    Campuzano, I.5    Rodger, P.M.6    Sadler, P.J.7
  • 163
    • 47749142090 scopus 로고    scopus 로고
    • Structural investigation of encapsulated fluoride in polyhedral oligomeric silsesquioxane cages using ion mobility mass spectrometry and molecular mechanics
    • Anderson, S.E., Bodzin, D.J., Haddad, T.S., Boatz, J.A., Mabry, J.M., Mitchell, C., and Bowers, M.T. (2008) Structural investigation of encapsulated fluoride in polyhedral oligomeric silsesquioxane cages using ion mobility mass spectrometry and molecular mechanics. Chem. Mater., 20: 4299-4309.
    • (2008) Chem. Mater. , vol.20 , pp. 4299-4309
    • Anderson, S.E.1    Bodzin, D.J.2    Haddad, T.S.3    Boatz, J.A.4    Mabry, J.M.5    Mitchell, C.6    Bowers, M.T.7
  • 164
    • 70349730066 scopus 로고    scopus 로고
    • A new, higher resolution, ion mobility mass spectrometer
    • Kemper, P.R., Dupuis, N.F., and Bowers, M.T. (2009) A new, higher resolution, ion mobility mass spectrometer. Int. J. Mass Spectrom., 287: 46-57.
    • (2009) Int. J. Mass Spectrom. , vol.287 , pp. 46-57
    • Kemper, P.R.1    Dupuis, N.F.2    Bowers, M.T.3
  • 165
    • 71949092837 scopus 로고    scopus 로고
    • Use of ion mobility mass spectrometry and a collision cross-section algorithm to study an organometallic ruthenium anticancer complex and its adducts with a DNA oligonucleotide
    • Williams, J.P., Lough, J.A., Campuzano, I., Richardson, K., and Sadler, P.J. (2009) Use of ion mobility mass spectrometry and a collision cross-section algorithm to study an organometallic ruthenium anticancer complex and its adducts with a DNA oligonucleotide. Rapid Comm. Mass Spectrom., 23: 3563-3569.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 3563-3569
    • Williams, J.P.1    Lough, J.A.2    Campuzano, I.3    Richardson, K.4    Sadler, P.J.5
  • 166
    • 78649877318 scopus 로고    scopus 로고
    • How useful is ion mobility mass spectrometry for structural biology? the relationship between protein crystal structures and their collision cross sections in the gas phase
    • Jurneczko, E. and Barran, P.E. (2011) How useful is ion mobility mass spectrometry for structural biology? The relationship between protein crystal structures and their collision cross sections in the gas phase. Analyst, 136: 20-28.
    • (2011) Analyst , vol.136 , pp. 20-28
    • Jurneczko, E.1    Barran, P.E.2
  • 167
    • 36248952562 scopus 로고    scopus 로고
    • High-field asymmetric waveform ion mobility spectrometry coupled with liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-FAIMS-MS/MS) multi-component bioanalytical method development, performance evaluation and demonstration of the constancy of the compensation voltage with change of mobile phase composition or flow rate
    • DOI 10.1002/rcm.3264
    • Wu, S.T., Xia, Y.-Q., and Jemal,M. (2007) High-field asymmetric waveform ion mobility spectrometry coupled with liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-FAIMS-MS/MS) multi-component bioanalytical method development, performance evaluation and demonstration of the constancy of the compensation voltage with change of mobile phase composition or flow rate. Rapid Comm. Mass Spectrom., 21: 3667-3676. (Pubitemid 350124636)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.22 , pp. 3667-3676
    • Wu, S.T.1    Xia, Y.-Q.2    Jemal, M.3
  • 168
    • 49749112037 scopus 로고    scopus 로고
    • Analysis of triazines and associated metabolites with electrospray ionization field-asymmetric ion mobility spectrometry/mass spectrometry
    • Mie, A., Sandulescu, M., Mathiasson, L., Emneus, J., and Reimann, C.T. (2008) Analysis of triazines and associated metabolites with electrospray ionization field-asymmetric ion mobility spectrometry/mass spectrometry. Anal. Sci., 24: 973-978.
    • (2008) Anal. Sci. , vol.24 , pp. 973-978
    • Mie, A.1    Sandulescu, M.2    Mathiasson, L.3    Emneus, J.4    Reimann, C.T.5
  • 169
    • 51949104348 scopus 로고    scopus 로고
    • LC-FAIMS-MS/MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components
    • Xia, Y.Q., Wu, S.T., and Jemal, M. (2008) LC-FAIMS-MS/MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components. Anal. Chem., 80: 7137-7143.
    • (2008) Anal. Chem. , vol.80 , pp. 7137-7143
    • Xia, Y.Q.1    Wu, S.T.2    Jemal, M.3
  • 170
    • 67650360325 scopus 로고    scopus 로고
    • High-field asymmetric waveform ion mobility spectrometry (FAIMS) coupled with high-resolution electron transfer dissociation mass spectrometry for the analysis of isobaric phosphopeptides
    • Xuan, Y., Creese, A.J., Horner, J.A., and Cooper, H.J. (2009) High-field asymmetric waveform ion mobility spectrometry (FAIMS) coupled with high-resolution electron transfer dissociation mass spectrometry for the analysis of isobaric phosphopeptides. Rapid Comm. Mass Spectrom., 23: 1963-1969.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 1963-1969
    • Xuan, Y.1    Creese, A.J.2    Horner, J.A.3    Cooper, H.J.4
  • 173
    • 77956416207 scopus 로고    scopus 로고
    • Differential mobility spectrometry/mass spectrometry: The design of a new mass spectrometer for real-time chemical analysis in the field
    • Manard, M.J., Trainham, R., Weeks, S., Coy, S.L., Krylov, E.V., and Nazarov, E.G. (2010) Differential mobility spectrometry/mass spectrometry: The design of a new mass spectrometer for real-time chemical analysis in the field. Int. J. Mass Spectrom., 295: 138-144.
    • (2010) Int. J. Mass Spectrom. , vol.295 , pp. 138-144
    • Manard, M.J.1    Trainham, R.2    Weeks, S.3    Coy, S.L.4    Krylov, E.V.5    Nazarov, E.G.6
  • 175
    • 78649699612 scopus 로고    scopus 로고
    • Miniaturized ultra high field asymmetric waveform ion mobility spectrometry combined with mass spectrometry for peptide analysis
    • Brown, L.J., Toutoungi, D.E., Devenport, N.A., Reynolds, J.C., Kaur-Atwal, G., Boyle, P., and Creaser, C.S. (2010) Miniaturized ultra high field asymmetric waveform ion mobility spectrometry combined with mass spectrometry for peptide analysis. Anal. Chem., 82: 9827-9834.
    • (2010) Anal. Chem. , vol.82 , pp. 9827-9834
    • Brown, L.J.1    Toutoungi, D.E.2    Devenport, N.A.3    Reynolds, J.C.4    Kaur-Atwal, G.5    Boyle, P.6    Creaser, C.S.7
  • 177
    • 51249122629 scopus 로고    scopus 로고
    • Evaluation of high-field asymmetric waveform ion mobility spectrometry mass spectrometry for the analysis of the mycotoxin zearalenone
    • McCooeye, M., Kolakowski, B., Boison, J., and Mester, Z. (2008) Evaluation of high-field asymmetric waveform ion mobility spectrometry mass spectrometry for the analysis of the mycotoxin zearalenone. Anal. Chim. Acta, 627: 112-116.
    • (2008) Anal. Chim. Acta , vol.627 , pp. 112-116
    • McCooeye, M.1    Kolakowski, B.2    Boison, J.3    Mester, Z.4
  • 178
    • 51949090818 scopus 로고    scopus 로고
    • Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics
    • Canterbury, J.D., Yi, X.H., Hoopmann, M.R., and MacCoss, M.J. (2008) Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics. Anal. Chem., 80: 6888-6897.
    • (2008) Anal. Chem. , vol.80 , pp. 6888-6897
    • Canterbury, J.D.1    Yi, X.H.2    Hoopmann, M.R.3    MacCoss, M.J.4
  • 179
    • 67650364357 scopus 로고    scopus 로고
    • Enhanced sensitivity in proteomics experiments using FAIMS coupled with a hybrid linear ion trap/orbitrap mass spectrometer
    • Saba, J., Bonneil, E., Pomies, C., Eng, K., and Thibault, P. (2009) Enhanced sensitivity in proteomics experiments using FAIMS coupled with a hybrid linear ion trap/orbitrap mass spectrometer. Journal of Proteome Research, 8: 3355-3366.
    • (2009) Journal of Proteome Research , vol.8 , pp. 3355-3366
    • Saba, J.1    Bonneil, E.2    Pomies, C.3    Eng, K.4    Thibault, P.5
  • 181
    • 77749322503 scopus 로고    scopus 로고
    • Structural characterization of phospholipids and peptides directly from tissue sections by MALDI traveling-wave ion mobility-mass spectrometry
    • Ridenour, W.B., Kliman, M., McLean, J.A., and Caprioli, R.M. (2010) Structural characterization of phospholipids and peptides directly from tissue sections by MALDI traveling-wave ion mobility-mass spectrometry. Anal. Chem., 82: 1881-1889.
    • (2010) Anal. Chem. , vol.82 , pp. 1881-1889
    • Ridenour, W.B.1    Kliman, M.2    McLean, J.A.3    Caprioli, R.M.4
  • 183
    • 0030670216 scopus 로고    scopus 로고
    • A novel ion funnel for focusing ions at elevated pressure using electrospray ionization mass spectrometry
    • DOI 10.1002/(SICI)1097-0231(19971030)11: 16<1813::AID-RCM87>3.0. CO;2-D
    • Shaffer, S.A., Tang, K.Q., Anderson, G.A., Prior, D.C., Udseth, H.R., and Smith, R.D. (1997) A novel ion funnel for focusing ions at elevated pressure using electrospray ionization mass spectrometry. Rapid Comm. Mass Spectrom., 11: 1813-1817. (Pubitemid 27498707)
    • (1997) Rapid Communications in Mass Spectrometry , vol.11 , Issue.16 , pp. 1813-1817
    • Shaffer, S.A.1    Tang, K.2    Anderson, G.A.3    Prior, D.C.4    Udseth, H.R.5    Smith, R.D.6
  • 187
    • 48849107031 scopus 로고    scopus 로고
    • Development of a high-throughput IMS-IMS-MS approach for analyzing mixtures of biomolecules
    • Kurulugama, R.T., Valentine, S.J., Sowell, R.A., and Clemmer, D.E. (2008) Development of a high-throughput IMS-IMS-MS approach for analyzing mixtures of biomolecules. Journal of Proteomics, 71: 318-331.
    • (2008) Journal of Proteomics , vol.71 , pp. 318-331
    • Kurulugama, R.T.1    Valentine, S.J.2    Sowell, R.A.3    Clemmer, D.E.4
  • 188
    • 41849100750 scopus 로고    scopus 로고
    • Pseudorandom sequence modifications for ion mobility orthogonal time-of-flight mass spectrometry
    • DOI 10.1021/ac7022712
    • Clowers, B.H., Belov, M.E., Prior, D.C., William, F.D., Ibrahim, Y., and Smith, R.D. (2008) Pseudorandom sequence modifications for ion mobility orthogonal time-of-flight mass spectrometry. Anal. Chem., 80: 2464-2473. (Pubitemid 351499829)
    • (2008) Analytical Chemistry , vol.80 , Issue.7 , pp. 2464-2473
    • Clowers, B.H.1    Belov, M.E.2    Prior, D.C.3    Danielson III, W.F.4    Ibrahim, Y.5    Smith, R.D.6
  • 191
    • 33846217403 scopus 로고    scopus 로고
    • Assessing the peak capacity of IMS-IMS separations of tryptic peptide ions in He at 300 K
    • DOI 10.1021/ac061567m
    • Merenbloom, S.I., Bohrer, B.C., Koeniger, S.L., and Clemmer, D.E. (2007) Assessing the peak capacity of IMS-IMS separations of tryptic peptide ions in He at 300 K. Anal. Chem., 79: 515-522. (Pubitemid 46106115)
    • (2007) Analytical Chemistry , vol.79 , Issue.2 , pp. 515-522
    • Merenbloom, S.I.1    Bohrer, B.C.2    Koeniger, S.L.3    Clemmer, D.E.4
  • 193
    • 33947371292 scopus 로고    scopus 로고
    • Multiplexed ion mobility spectrometry-orthogonal time-of-flight mass spectrometry
    • DOI 10.1021/ac0617316
    • Belov, M.E., Buschbach, M.A., Prior, D.C., Tang, K.Q., and Smith, R.D. (2007) Multiplexed ion mobility spectrometry-orthogonal time-of-flight mass spectrometry. Anal. Chem., 79: 2451-2462. (Pubitemid 46449027)
    • (2007) Analytical Chemistry , vol.79 , Issue.6 , pp. 2451-2462
    • Belov, M.E.1    Buschbach, M.A.2    Prior, D.C.3    Tang, K.4    Smith, R.D.5
  • 194
    • 26844503278 scopus 로고
    • Molecular beams of macroions
    • Dole, M., Mack, L.L., and Hines, R.L. (1968) Molecular beams of macroions. J. Chem. Phys., 49: 2240-2249.
    • (1968) J. Chem. Phys. , vol.49 , pp. 2240-2249
    • Dole, M.1    MacK, L.L.2    Hines, R.L.3
  • 195
    • 33845471401 scopus 로고
    • Negative-ion production with the electrospray ion-source
    • Yamashita,M. and Fenn, J.B. (1984) Negative-ion production with the electrospray ion-source. J. Phys. Chem., 88: 4671-4675.
    • (1984) J. Phys. Chem. , vol.88 , pp. 4671-4675
    • Yamashita, M.1    Fenn, J.B.2
  • 196
    • 0024438708 scopus 로고
    • Electrospray ionization for mass spectrometry of large biomolecules
    • Fenn, J.B., Mann, M., Meng, C.K., Wong, S.F., and Whitehouse, C.M. (1989) Electrospray ionization for mass-spectrometry of large biomolecules. Science, 246: 64-71. (Pubitemid 19252085)
    • (1989) Science , vol.246 , Issue.4926 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 197
    • 0000178042 scopus 로고
    • Micro-electrospray mass-spectrometry - Ultra-high-sensitivity analysis of peptides and proteins
    • Emmett, M.R. and Caprioli, R.M. (1994) Micro-electrospray mass-spectrometry - Ultra-high-sensitivity analysis of peptides and proteins. J. Am. Soc. Mass Spectrom., 5: 605-613.
    • (1994) J. Am. Soc. Mass Spectrom. , vol.5 , pp. 605-613
    • Emmett, M.R.1    Caprioli, R.M.2
  • 198
    • 0000217562 scopus 로고
    • Electrospray and Taylor-Cone theory, Doles beam of macromolecules at last
    • Wilm, M.S. and Mann, M. (1994) Electrospray and Taylor-Cone theory, Doles beam of macromolecules at last. Int. J. Mass Spectrom., 136: 167-180.
    • (1994) Int. J. Mass Spectrom. , vol.136 , pp. 167-180
    • Wilm, M.S.1    Mann, M.2
  • 199
    • 0029685702 scopus 로고    scopus 로고
    • Analytical properties of the nanoelectrospray ion source
    • Wilm, M. and Mann, M. (1996) Analytical properties of the nanoelectrospray ion source. Anal. Chem., 68: 1-8.
    • (1996) Anal. Chem. , vol.68 , pp. 1-8
    • Wilm, M.1    Mann, M.2
  • 200
    • 77952895139 scopus 로고    scopus 로고
    • Desorption electrospray ionization mass spectrometric analysis of organophosphorus chemical warfare agents using ion mobility and tandem mass spectrometry
    • D'Agostino, P.A. and Chenier, C.L. (2010) Desorption electrospray ionization mass spectrometric analysis of organophosphorus chemical warfare agents using ion mobility and tandem mass spectrometry. Rapid Comm. Mass Spectrom., 24: 1617-1624.
    • (2010) Rapid Comm. Mass Spectrom. , vol.24 , pp. 1617-1624
    • D'agostino, P.A.1    Chenier, C.L.2
  • 201
    • 69249146053 scopus 로고    scopus 로고
    • Direct analysis of pharmaceutical formulations from non-bonded reversed-phase thin-layer chromatography plates by desorption electrospray ionisation ion mobility mass spectrometry
    • Harry, E.L., Reynolds, J.C., Bristow, A.W.T.,Wilson, I.D., and Creaser, C.S. (2009) Direct analysis of pharmaceutical formulations from non-bonded reversed-phase thin-layer chromatography plates by desorption electrospray ionisation ion mobility mass spectrometry. Rapid Comm. Mass Spectrom., 23: 2597-2604.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 2597-2604
    • Harry, E.L.1    Reynolds, J.C.2    Bristow, A.W.T.3    Wilson, I.D.4    Creaser, C.S.5
  • 202
    • 5644249240 scopus 로고    scopus 로고
    • Mass spectrometry sampling under ambient conditions with desorption electrospray ionization
    • DOI 10.1126/science.1104404
    • Takats, Z. (2004) Mass spectrometry sampling under ambient conditions with desorption electrospray ionization. Science, 306: 471-473. (Pubitemid 39372443)
    • (2004) Science , vol.306 , Issue.5695 , pp. 471-473
    • Takats, Z.1    Wiseman, J.M.2    Gologan, B.3    Cooks, R.G.4
  • 203
    • 28544441463 scopus 로고    scopus 로고
    • Direct analysis of pharmaceutical drug formulations using ion mobility spectrometry/quadrupole-time-of-flight mass spectrometry combined with desorption electrospray ionization
    • DOI 10.1021/ac051277q
    • Weston, D.J., Bateman, R., Wilson, I.D., Wood, T.R., and Creaser, C.S. (2005) Direct analysis of pharmaceutical drug formulations using ion mobility spectrometry/quadrupole-time-of flight mass spectrometry combined with desorption electrospray ionization. Anal. Chem., 77: 7572-7580. (Pubitemid 41746224)
    • (2005) Analytical Chemistry , vol.77 , Issue.23 , pp. 7572-7580
    • Weston, D.J.1    Bateman, R.2    Wilson, I.D.3    Wood, T.R.4    Creaser, C.5
  • 205
    • 77953916803 scopus 로고    scopus 로고
    • Laserspray ionization (LSI) ion mobility spectrometry (IMS) mass spectrometry
    • Inutan, E. and Trimpin, S. (2010) Laserspray ionization (LSI) ion mobility spectrometry (IMS) mass spectrometry. J. Am. Soc. Mass Spectrom., 21: 1260-1264.
    • (2010) J. Am. Soc. Mass Spectrom. , vol.21 , pp. 1260-1264
    • Inutan, E.1    Trimpin, S.2
  • 207
    • 35848971014 scopus 로고    scopus 로고
    • Analysis of chemical warfare agents in food products by atmospheric pressure ionization-high field asymmetric waveform ion mobility spectrometry-mass spectrometry
    • DOI 10.1021/ac070816j
    • Kolakowski, B.M., D'Agostino, P.A., Chenier, C., and Mester, Z. (2007) Analysis of chemical warfare agents in food products by atmospheric pressure ionization-high field asymmetric waveform ion mobility spectrometry-mass spectrometry. Anal. Chem., 79: 8257-8265. (Pubitemid 350060025)
    • (2007) Analytical Chemistry , vol.79 , Issue.21 , pp. 8257-8265
    • Kolakowski, B.M.1    D'Agostino, P.A.2    Chenier, C.3    Mester, Z.4
  • 208
    • 78650779490 scopus 로고    scopus 로고
    • Application of the Mason-Schamp equation and ion mobility mass spectrometry to identify structurally related compounds in crude oil
    • Ahmed, A., Cho, Y.J., No, M.H., Koh, J., Tomczyk, N., Giles, K., Yoo, J.S., and Kim, S. (2011) Application of the Mason-Schamp equation and ion mobility mass spectrometry to identify structurally related compounds in crude oil. Anal. Chem., 83: 77-83.
    • (2011) Anal. Chem. , vol.83 , pp. 77-83
    • Ahmed, A.1    Cho, Y.J.2    No, M.H.3    Koh, J.4    Tomczyk, N.5    Giles, K.6    Yoo, J.S.7    Kim, S.8
  • 209
    • 77955034971 scopus 로고    scopus 로고
    • Atmospheric pressure corona discharge ionisation and ion mobility spectrometry/mass spectrometry study of the negative corona discharge in high purity oxygen and oxygen/nitrogen mixtures
    • Sabo, M., Páleník, J., Kučera, M., Han, H., Wang, H., Chu, Y., and Matejčík, Š. (2010) Atmospheric pressure corona discharge ionisation and ion mobility spectrometry/mass spectrometry study of the negative corona discharge in high purity oxygen and oxygen/nitrogen mixtures. Int. J. Mass Spectrom., 293: 23-27.
    • (2010) Int. J. Mass Spectrom. , vol.293 , pp. 23-27
    • Sabo, M.1    Páleník, J.2    Kučera, M.3    Han, H.4    Wang, H.5    Chu, Y.6    Matejčík, S.7
  • 210
    • 77955922392 scopus 로고    scopus 로고
    • Separation of different ion structures in atmospheric pressure photoionization-ion mobility spectrometry-mass spectrometry (APPI-IMS-MS)
    • Laakia, J., Adamov, A., Jussila, M., Pedersen, C.S., Sysoev, A.A., and Kotiaho, T. (2010) Separation of different ion structures in atmospheric pressure photoionization-ion mobility spectrometry-mass spectrometry (APPI-IMS-MS). J. Am. Soc. Mass Spectrom., 21: 1565-1572.
    • (2010) J. Am. Soc. Mass Spectrom. , vol.21 , pp. 1565-1572
    • Laakia, J.1    Adamov, A.2    Jussila, M.3    Pedersen, C.S.4    Sysoev, A.A.5    Kotiaho, T.6
  • 212
    • 77951053930 scopus 로고    scopus 로고
    • Dual source ion mobility-mass spectrometer for direct comparison of electrospray ionization and MALDI collision cross section measurements
    • Sundarapandian, S., May, J.C., and McLean, J.A. (2010) Dual source ion mobility-mass spectrometer for direct comparison of electrospray ionization and MALDI collision cross section measurements. Anal. Chem., 82: 3247-3254.
    • (2010) Anal. Chem. , vol.82 , pp. 3247-3254
    • Sundarapandian, S.1    May, J.C.2    McLean, J.A.3
  • 215
    • 77952521680 scopus 로고    scopus 로고
    • Structural mass spectrometry analysis of lipid changes in a Drosophila epilepsy model brain
    • Kliman, M., Vijayakrishnan, N., Wang, L., Tapp, J.T., Broadie, K., and McLean, J.A. (2010) Structural mass spectrometry analysis of lipid changes in a Drosophila epilepsy model brain. Molecular BioSystems, 6: 958-966.
    • (2010) Molecular BioSystems , vol.6 , pp. 958-966
    • Kliman, M.1    Vijayakrishnan, N.2    Wang, L.3    Tapp, J.T.4    Broadie, K.5    McLean, J.A.6
  • 217
    • 34547881888 scopus 로고    scopus 로고
    • Profiling and imaging of tissues by imaging ion mobility-mass spectrometry
    • DOI 10.1002/jms.1254
    • McLean, J.A., Ridenour, W.B., and Caprioli, R.M. (2007) Profiling and imaging of tissues by imaging ion mobility-mass spectrometry. J. Mass Spectrom., 42: 1099-1105. (Pubitemid 47255462)
    • (2007) Journal of Mass Spectrometry , vol.42 , Issue.8 , pp. 1099-1105
    • McLean, J.A.1    Ridenour, W.B.2    Caprioli, R.M.3
  • 218
    • 56449126797 scopus 로고    scopus 로고
    • Matrix-assisted laser desorption/ionization-ion mobility separation-mass spectrometry imaging of vinblastine in whole body tissue sections
    • Trim, P.J., Henson, C.M., Avery, J.L., McEwen, A., Snel,M.F., Claude, E., Marshall, P.S.,West, A., Princivalle, A.P., and Clench, M.R. (2008) Matrix-assisted laser desorption/ionization-ion mobility separation-mass spectrometry imaging of vinblastine in whole body tissue sections. Anal. Chem., 80: 8628-8634.
    • (2008) Anal. Chem. , vol.80 , pp. 8628-8634
    • Trim, P.J.1    Henson, C.M.2    Avery, J.L.3    McEwen, A.4    Snel, M.F.5    Claude, E.6    Marshall, P.S.7    West, A.8    Princivalle, A.P.9    Clench, M.R.10
  • 219
    • 66449091490 scopus 로고    scopus 로고
    • Detergent addition to tryptic digests and ion mobility separation prior toMS/MS improves peptide yield and protein identification for in situ proteomic investigation of frozen and formalin-fixed paraffin-embedded adenocarcinoma tissue sections
    • Djidja, M.C., Francese, S., Loadman, P.M., Sutton, C.W., Scriven, P., Claude, E., Snel, M.F., Franck, J., Salzet, M., and Clench, M.R. (2009) Detergent addition to tryptic digests and ion mobility separation prior toMS/MS improves peptide yield and protein identification for in situ proteomic investigation of frozen and formalin-fixed paraffin-embedded adenocarcinoma tissue sections. Proteomics, 9: 2750-2763.
    • (2009) Proteomics , vol.9 , pp. 2750-2763
    • Djidja, M.C.1    Francese, S.2    Loadman, P.M.3    Sutton, C.W.4    Scriven, P.5    Claude, E.6    Snel, M.F.7    Franck, J.8    Salzet, M.9    Clench, M.R.10
  • 220
    • 70349974835 scopus 로고    scopus 로고
    • MALDI-ion mobility separation-mass spectrometry imaging of glucose-regulated protein 78 kDa (Grp78) in human formalin-fixed, paraffin-embedded pancreatic adenocarcinoma tissue sections
    • Djidja, M.C., Claude, E., Snel, M.F., Scriven, P., Francese, S., Carolan, V., and Clench, M.R. (2009) MALDI-ion mobility separation-mass spectrometry imaging of glucose-regulated protein 78 kDa (Grp78) in human formalin-fixed, paraffin-embedded pancreatic adenocarcinoma tissue sections. Journal of Proteome Research, 8: 4876-4884.
    • (2009) Journal of Proteome Research , vol.8 , pp. 4876-4884
    • Djidja, M.C.1    Claude, E.2    Snel, M.F.3    Scriven, P.4    Francese, S.5    Carolan, V.6    Clench, M.R.7
  • 223
    • 56949099562 scopus 로고    scopus 로고
    • Studies of peptide a- and b-type fragment ions using stable isotope labeling and integrated ion mobility/tandem mass spectrometry
    • Riba Garcia, I., Giles, K., Bateman, R.H., and Gaskell, S.J. (2008) Studies of peptide a- and b-type fragment ions using stable isotope labeling and integrated ion mobility/tandem mass spectrometry. J. Am. Soc. Mass Spectrom., 19: 1781-1787.
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 1781-1787
    • Riba Garcia, I.1    Giles, K.2    Bateman, R.H.3    Gaskell, S.J.4
  • 224
    • 71449105844 scopus 로고    scopus 로고
    • Structural characterization of ß-amyloid oligomer-aggregates by ion mobility mass spectrometry and electron spin resonance spectroscopy
    • Iuraşcu, M.I., Cozma, C., Tomczyk, N., Rontree, J., Desor, M., Drescher, M., and Przybylski, M. (2009) Structural characterization of ß-amyloid oligomer-aggregates by ion mobility mass spectrometry and electron spin resonance spectroscopy. Anal. Bioanal. Chem., 395: 2509-2519.
    • (2009) Anal. Bioanal. Chem. , vol.395 , pp. 2509-2519
    • Iuraşcu, M.I.1    Cozma, C.2    Tomczyk, N.3    Rontree, J.4    Desor, M.5    Drescher, M.6    Przybylski, M.7
  • 225
    • 77956898604 scopus 로고    scopus 로고
    • Determining the topology of virus assembly intermediates using ion mobility spectrometry-mass spectrometry
    • Knapman, T.W., Morton, V.L., Stonehouse, N.J., Stockley, P.G., and Ashcroft, A.E. (2010) Determining the topology of virus assembly intermediates using ion mobility spectrometry-mass spectrometry. Rapid Comm. Mass Spectrom., 24: 3033-3042.
    • (2010) Rapid Comm. Mass Spectrom. , vol.24 , pp. 3033-3042
    • Knapman, T.W.1    Morton, V.L.2    Stonehouse, N.J.3    Stockley, P.G.4    Ashcroft, A.E.5
  • 226
    • 70649091226 scopus 로고    scopus 로고
    • Online hydrogen/deuterium exchange performed in the ion mobility cell of a hybrid mass spectrometer
    • Nagy, K., Redeuil, K., and Rezzi, S. (2009) Online hydrogen/deuterium exchange performed in the ion mobility cell of a hybrid mass spectrometer. Anal. Chem., 81: 9365-9371.
    • (2009) Anal. Chem. , vol.81 , pp. 9365-9371
    • Nagy, K.1    Redeuil, K.2    Rezzi, S.3
  • 227
    • 41849105800 scopus 로고    scopus 로고
    • Gas-phase proton-transfer chemistry coupled with TOF mass spectrometry and ion mobility-MS for the facile analysis of poly(ethylene glycols) and PEGylated polypeptide conjugates
    • DOI 10.1021/ac7020163
    • Bagal, D., Zhang, H., and Schnier, P.D. (2008) Gas-phase proton-transfer chemistry coupled with TOF mass spectrometry and ion mobility-MS for the facile analysis of poly(ethylene glycols) and PEGylated polypeptide conjugates. Anal. Chem., 80: 2408-2418. (Pubitemid 351499822)
    • (2008) Analytical Chemistry , vol.80 , Issue.7 , pp. 2408-2418
    • Bagal, D.1    Zhang, H.2    Schnier, P.D.3
  • 228
    • 77958099293 scopus 로고    scopus 로고
    • Ion mobility-mass spectrometry of phosphorylase B ions generated with supercharging reagents but in charge-reducing buffer
    • Hogan, C.J., Loo, R.R.O., Loo, J.A., and de la Moraa, J.F. (2010) Ion mobility-mass spectrometry of phosphorylase B ions generated with supercharging reagents but in charge-reducing buffer. Phys. Chem. Chem. Phys., 12: 13476-13483.
    • (2010) Phys. Chem. Chem. Phys. , vol.12 , pp. 13476-13483
    • Hogan, C.J.1    Loo, R.R.O.2    Loo, J.A.3    De La Moraa, J.F.4
  • 230
    • 36348991325 scopus 로고    scopus 로고
    • Monitoring Copopulated Conformational States During Protein Folding Events Using Electrospray Ionization-Ion Mobility Spectrometry-Mass Spectrometry
    • DOI 10.1016/j.jasms.2007.09.017, PII S1044030507008501
    • Smith, D.P., Giles, K., Bateman, R.H., Radford, S.E., and Ashcroft, A.E. (2007) Monitoring copopulated conformational states during protein folding events using electrospray ionization-ion mobility spectrometry-mass spectrometry. J. Am. Soc. Mass Spectrom., 18: 2180-2190. (Pubitemid 350161334)
    • (2007) Journal of the American Society for Mass Spectrometry , vol.18 , Issue.12 , pp. 2180-2190
    • Smith, D.P.1    Giles, K.2    Bateman, R.H.3    Radford, S.E.4    Ashcroft, A.E.5
  • 231
    • 58149182318 scopus 로고    scopus 로고
    • Travelling wave ion mobility mass spectrometry studies of protein structure: Biological significance and comparison with X-ray crystallography and nuclear magnetic resonance spectroscopy measurements
    • Scarff, C.A., Thalassinos, K., Hilton, G.R., and Scrivens, J.H. (2008) Travelling wave ion mobility mass spectrometry studies of protein structure: Biological significance and comparison with X-ray crystallography and nuclear magnetic resonance spectroscopy measurements. Rapid Comm. Mass Spectrom., 22: 3297-3304.
    • (2008) Rapid Comm. Mass Spectrom. , vol.22 , pp. 3297-3304
    • Scarff, C.A.1    Thalassinos, K.2    Hilton, G.R.3    Scrivens, J.H.4
  • 232
    • 70349108740 scopus 로고    scopus 로고
    • Collision induced unfolding of protein ions in the gas phase studied by ion mobility-mass spectrometry: The effect of ligand binding on conformational stability
    • Hopper, J.T.S. and Oldham, N.J. (2009) Collision induced unfolding of protein ions in the gas phase studied by ion mobility-mass spectrometry: The effect of ligand binding on conformational stability. J. Am. Soc. Mass Spectrom., 20: 1851-1858.
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , pp. 1851-1858
    • Hopper, J.T.S.1    Oldham, N.J.2
  • 234
    • 62149117617 scopus 로고    scopus 로고
    • Probing hemoglobin structure by means of traveling-wave ion mobility mass spectrometry
    • Scarff,C.A., Patel,V.J., Thalassinos,K., and Scrivens, J.H. (2009) Probing hemoglobin structure by means of traveling-wave ion mobility mass spectrometry. J. Am. Soc. Mass Spectrom., 20: 625-631.
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , pp. 625-631
    • Scarff, C.A.1    Patel, V.J.2    Thalassinos, K.3    Scrivens, J.H.4
  • 235
    • 58149182319 scopus 로고    scopus 로고
    • Ion mobility augments the utility of mass spectrometry in the identification of human hemoglobin variants
    • Williams, J.P., Giles, K., Green, B.N., Scrivens, J.H., and Bateman, R.H. (2008) Ion mobility augments the utility of mass spectrometry in the identification of human hemoglobin variants. Rapid Comm. Mass Spectrom., 22: 3179-3186.
    • (2008) Rapid Comm. Mass Spectrom. , vol.22 , pp. 3179-3186
    • Williams, J.P.1    Giles, K.2    Green, B.N.3    Scrivens, J.H.4    Bateman, R.H.5
  • 237
    • 65049088697 scopus 로고    scopus 로고
    • Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples
    • Fenn, L.S., Kliman, M., Mahsut, A., Zhao, S.R., and McLean, J.A. (2009) Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples. Anal. Bioanal. Chem., 394: 235-244.
    • (2009) Anal. Bioanal. Chem. , vol.394 , pp. 235-244
    • Fenn, L.S.1    Kliman, M.2    Mahsut, A.3    Zhao, S.R.4    McLean, J.A.5
  • 238
    • 48949106229 scopus 로고    scopus 로고
    • An approach to enhancing coverage of the urinary metabonome using liquid chromatography-ion mobility-mass spectrometry
    • Harry, E.L., Weston, D.J., Bristow, A.W.T., Wilson, I.D., and Creaser, C.S. (2008) An approach to enhancing coverage of the urinary metabonome using liquid chromatography-ion mobility-mass spectrometry. J. Chrom. B, 871: 357-361.
    • (2008) J. Chrom. B , vol.871 , pp. 357-361
    • Harry, E.L.1    Weston, D.J.2    Bristow, A.W.T.3    Wilson, I.D.4    Creaser, C.S.5
  • 240
    • 70349629998 scopus 로고    scopus 로고
    • Monitoring dynamic changes in lymph metabolome of fasting and fed rats by electrospray ionization-ion mobility mass spectrometry (ESI-IMMS)
    • Kaplan, K., Dwivedi, P., Davidson, S., Yang, Q., Tso, P., Siems, W., and Hill, H.H. (2009) Monitoring dynamic changes in lymph metabolome of fasting and fed rats by electrospray ionization-ion mobility mass spectrometry (ESI-IMMS). Anal. Chem., 81: 7944-7953.
    • (2009) Anal. Chem. , vol.81 , pp. 7944-7953
    • Kaplan, K.1    Dwivedi, P.2    Davidson, S.3    Yang, Q.4    Tso, P.5    Siems, W.6    Hill, H.H.7
  • 241
    • 34250731277 scopus 로고    scopus 로고
    • Rapid Resolution of Carbohydrate Isomers by Electrospray Ionization Ambient Pressure Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry (ESI-APIMS-TOFMS)
    • DOI 10.1016/j.jasms.2007.04.007, PII S1044030507003285
    • Dwivedi, P., Bendiak, B., Clowers, B.H., and Hill, H.H. (2007) Rapid resolution of carbohydrate isomers by electrospray ionization ambient pressure ion mobility spectrometry-time-of-flight mass spectrometry (ESI-APIMS-TOFMS). J. Am. Soc. Mass Spectrom., 18: 1163-1175. (Pubitemid 46963601)
    • (2007) Journal of the American Society for Mass Spectrometry , vol.18 , Issue.7 , pp. 1163-1175
    • Dwivedi, P.1    Bendiak, B.2    Clowers, B.H.3    Hill Jr., H.H.4
  • 242
    • 68349114989 scopus 로고    scopus 로고
    • Ion mobility-mass spectrometry analysis of isomeric carbohydrate precursor ions
    • Zhu, M., Bendiak, B., Clowers, B., and Hill, H.H. (2009) Ion mobility-mass spectrometry analysis of isomeric carbohydrate precursor ions. Anal. Bioanal. Chem., 394: 1853-1867.
    • (2009) Anal. Bioanal. Chem. , vol.394 , pp. 1853-1867
    • Zhu, M.1    Bendiak, B.2    Clowers, B.3    Hill, H.H.4
  • 243
    • 70349854668 scopus 로고    scopus 로고
    • Peak width-mass correlation in CID MS/MS of isomeric oligosaccharides using traveling-wave ion mobility mass spectrometry
    • Yamagaki, T. and Sato, A. (2009) Peak width-mass correlation in CID MS/MS of isomeric oligosaccharides using traveling-wave ion mobility mass spectrometry. J. Mass Spectrom., 44: 1509-1517.
    • (2009) J. Mass Spectrom. , vol.44 , pp. 1509-1517
    • Yamagaki, T.1    Sato, A.2
  • 244
    • 55849129998 scopus 로고    scopus 로고
    • Enhanced carbohydrate structural selectivity in ion mobility-mass spectrometry analyses by boronic acid derivatization
    • Fenn, L.S. and McLean, J.A. (2008) Enhanced carbohydrate structural selectivity in ion mobility-mass spectrometry analyses by boronic acid derivatization. Chem. Comm., 5505-5507.
    • (2008) Chem. Comm. , pp. 5505-5507
    • Fenn, L.S.1    McLean, J.A.2
  • 245
    • 69549121810 scopus 로고    scopus 로고
    • The contributions of molecular framework to IMS collision cross-sections of gas-phase peptide ions
    • Tao, L., Dahl, D.B., Pérez, L.M., and Russell, D.H. (2009) The contributions of molecular framework to IMS collision cross-sections of gas-phase peptide ions. J. Am. Soc. Mass Spectrom., 20: 1593-1602.
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , pp. 1593-1602
    • Tao, L.1    Dahl, D.B.2    Pérez, L.M.3    Russell, D.H.4
  • 247
    • 70349970185 scopus 로고    scopus 로고
    • Simultaneous glycoproteomics on the basis of structure using ion mobility-mass spectrometry
    • Fenn, L.S. and McLean, J.A. (2009) Simultaneous glycoproteomics on the basis of structure using ion mobility-mass spectrometry. Molecular BioSystems, 5: 1298-1302.
    • (2009) Molecular BioSystems , vol.5 , pp. 1298-1302
    • Fenn, L.S.1    McLean, J.A.2
  • 250
    • 38349085042 scopus 로고    scopus 로고
    • Determination of Nglycosylation sites and site heterogeneity in a monoclonal antibody by electrospray quadrupole ion-mobility time-of-flight mass spectrometry
    • Olivova, P., Chen, W.B., Chakraborty, A.B., and Gebler, J.C. (2008) Determination of Nglycosylation sites and site heterogeneity in a monoclonal antibody by electrospray quadrupole ion-mobility time-of-flight mass spectrometry. Rapid Comm. Mass Spectrom., 22: 29-40.
    • (2008) Rapid Comm. Mass Spectrom. , vol.22 , pp. 29-40
    • Olivova, P.1    Chen, W.B.2    Chakraborty, A.B.3    Gebler, J.C.4
  • 251
    • 70349762761 scopus 로고    scopus 로고
    • Electrospray ionization quadrupole ion-mobility time-of-flight mass spectrometry as a tool to distinguish the lot-to-lot heterogeneity in N-glycosylation profile of the therapeutic monoclonal antibody trastuzumab
    • Damen, C.W.N., Chen, W.B., Chakraborty, A.B., van Oosterhout, M., Mazzeo, J.R., Gebler, J.C., Schellens, J.H.M., Rosing, H., and Beijnen, J.H. (2009) Electrospray ionization quadrupole ion-mobility time-of-flight mass spectrometry as a tool to distinguish the lot-to-lot heterogeneity in N-glycosylation profile of the therapeutic monoclonal antibody trastuzumab. J. Am. Soc.Mass Spectrom., 20: 2021-2033.
    • (2009) J. Am. Soc.Mass Spectrom. , vol.20 , pp. 2021-2033
    • Damen, C.W.N.1    Chen, W.B.2    Chakraborty, A.B.3    Van Oosterhout, M.4    Mazzeo, J.R.5    Gebler, J.C.6    Schellens, J.H.M.7    Rosing, H.8    Beijnen, J.H.9
  • 252
    • 68049103219 scopus 로고    scopus 로고
    • Extending mass spectrometry contribution to therapeutic monoclonal antibody lead optimization: Characterization of immune complexes using noncovalent ESI-MS
    • Atmanene, C., Wagner-Rousset, E., Malissard, M., Chol, B., Robert, A., Corvaia, N., Van Dorsselaer, A., Beck, A., and Sanglier-Cianferani, S. (2009) Extending mass spectrometry contribution to therapeutic monoclonal antibody lead optimization: Characterization of immune complexes using noncovalent ESI-MS. Anal. Chem., 81: 6364-6373.
    • (2009) Anal. Chem. , vol.81 , pp. 6364-6373
    • Atmanene, C.1    Wagner-Rousset, E.2    Malissard, M.3    Chol, B.4    Robert, A.5    Corvaia, N.6    Van Dorsselaer, A.7    Beck, A.8    Sanglier-Cianferani, S.9
  • 253
    • 77955606264 scopus 로고    scopus 로고
    • Resolving disulfide structural isoforms of IgG2 monoclonal antibodies by ion mobility mass spectrometry
    • Bagal, D., Valliere-Douglass, J.F., Balland, A., and Schnier, P.D. (2010) Resolving disulfide structural isoforms of IgG2 monoclonal antibodies by ion mobility mass spectrometry. Anal. Chem., 82: 6751-6755.
    • (2010) Anal. Chem. , vol.82 , pp. 6751-6755
    • Bagal, D.1    Valliere-Douglass, J.F.2    Balland, A.3    Schnier, P.D.4
  • 254
    • 77951829683 scopus 로고    scopus 로고
    • Combination of noncovalent mass spectrometry and traveling wave ion mobility spectrometry reveals sugar-induced conformational changes of central glycolytic genes repressor/DNA complex
    • Atmanene, C., Chaix, D., Bessin, Y., Declerck, N., van Dorsselaer, A., and Sanglier-Cianferani, S. (2010) Combination of noncovalent mass spectrometry and traveling wave ion mobility spectrometry reveals sugar-induced conformational changes of central glycolytic genes repressor/DNA complex. Anal. Chem., 82: 3597-3605.
    • (2010) Anal. Chem. , vol.82 , pp. 3597-3605
    • Atmanene, C.1    Chaix, D.2    Bessin, Y.3    Declerck, N.4    Van Dorsselaer, A.5    Sanglier-Cianferani, S.6
  • 255
    • 79960428001 scopus 로고    scopus 로고
    • Utilizing ion mobility spectrometry combined with mass spectrometry for analysis of pharmaceutical compounds
    • Mauriala, T., Adamov, A., Laakia, J., Sysoev, A., Kotiaho, T., and Ketola, R. (2008) Utilizing ion mobility spectrometry combined with mass spectrometry for analysis of pharmaceutical compounds. Eur. J. Pharmaceut. Sci., 34: S39-S40.
    • (2008) Eur. J. Pharmaceut. Sci. , vol.34
    • Mauriala, T.1    Adamov, A.2    Laakia, J.3    Sysoev, A.4    Kotiaho, T.5    Ketola, R.6
  • 256
    • 60149101752 scopus 로고    scopus 로고
    • Pharmaceutical metabolite profiling using quadrupole/ion mobility spectrometry/time-of-flight mass spectrometry
    • Chan, E.C.Y., New, L.S., Yap, C.W., and Goh, L.T. (2009) Pharmaceutical metabolite profiling using quadrupole/ion mobility spectrometry/time-of-flight mass spectrometry. Rapid Comm. Mass Spectrom., 23: 384-394.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 384-394
    • Chan, E.C.Y.1    New, L.S.2    Yap, C.W.3    Goh, L.T.4
  • 258
    • 77954641329 scopus 로고    scopus 로고
    • UVinduced bond modifications in thymine and thymine dideoxynucleotide: Structural elucidation of isomers by differential mobility mass spectrometry
    • St-Jacques, A., Anichina, J., Schneider, B.B., Covey, T.R., and Bohme, D.K. (2010) UVinduced bond modifications in thymine and thymine dideoxynucleotide: Structural elucidation of isomers by differential mobility mass spectrometry. Anal. Chem., 82: 6163-6167.
    • (2010) Anal. Chem. , vol.82 , pp. 6163-6167
    • St-Jacques, A.1    Anichina, J.2    Schneider, B.B.3    Covey, T.R.4    Bohme, D.K.5
  • 259
    • 77953959136 scopus 로고    scopus 로고
    • Separation of isomers L-alanine and sarcosine in urine by electrospray ionization and tandem differential mobility analysis-mass spectrometry
    • Martínez-Lozano, P. and Rus, J. (2010) Separation of isomers L-alanine and sarcosine in urine by electrospray ionization and tandem differential mobility analysis-mass spectrometry. J. Am. Soc. Mass Spectrom., 21: 1129-1132.
    • (2010) J. Am. Soc. Mass Spectrom. , vol.21 , pp. 1129-1132
    • Martínez-Lozano, P.1    Rus, J.2
  • 260
    • 77957141424 scopus 로고    scopus 로고
    • Structures of metallosupramolecular coordination assemblies can be obtained by ion mobility spectrometry-mass spectrometry
    • Brocker, E.R., Anderson, S.E., Northrop, B.H., Stang, P.J., and Bowers, M.T. (2010) Structures of metallosupramolecular coordination assemblies can be obtained by ion mobility spectrometry-mass spectrometry. J. Am. Chem. Soc., 132: 13486-13494.
    • (2010) J. Am. Chem. Soc. , vol.132 , pp. 13486-13494
    • Brocker, E.R.1    Anderson, S.E.2    Northrop, B.H.3    Stang, P.J.4    Bowers, M.T.5
  • 261
    • 70450177292 scopus 로고    scopus 로고
    • Self-assembly and traveling wave ion mobility mass spectrometry analysis of hexacadmium macrocycles
    • Chan, Y.T., Li, X.P., Soler, M., Wang, J.L., Wesdemiotis, C., and Newkome, G.R. (2009) Self-assembly and traveling wave ion mobility mass spectrometry analysis of hexacadmium macrocycles. J. Am. Chem. Soc., 131: 16395-16397.
    • (2009) J. Am. Chem. Soc. , vol.131 , pp. 16395-16397
    • Chan, Y.T.1    Li, X.P.2    Soler, M.3    Wang, J.L.4    Wesdemiotis, C.5    Newkome, G.R.6
  • 262
    • 77956526601 scopus 로고    scopus 로고
    • Hexameric palladium(II) terpyridyl metallomacrocycles: Assembly with 4,4'- bipyridine and characterization by TWIM mass spectrometry
    • Perera, S., Li, X.P., Soler, M., Schultz, A., Wesdemiotis, C., Moorefield, C.N., and Newkome, G.R. (2010) Hexameric palladium(II) terpyridyl metallomacrocycles: Assembly with 4,4'- bipyridine and characterization by TWIM mass spectrometry. Angew. Chem. Int. Ed., 49: 6539-6544.
    • (2010) Angew. Chem. Int. Ed. , vol.49 , pp. 6539-6544
    • Perera, S.1    Li, X.P.2    Soler, M.3    Schultz, A.4    Wesdemiotis, C.5    Moorefield, C.N.6    Newkome, G.R.7
  • 264
    • 77953007110 scopus 로고    scopus 로고
    • Chiral and structural analysis of biomolecules using mass spectrometry and ion mobility-mass spectrometry
    • Enders, J.R. and McLean, J.A. (2010) Chiral and structural analysis of biomolecules using mass spectrometry and ion mobility-mass spectrometry. Chirality, 21: E253-E264.
    • (2010) Chirality , vol.21
    • Enders, J.R.1    McLean, J.A.2
  • 266
    • 35848933261 scopus 로고    scopus 로고
    • Resolving oligomers from fully grown polymers with IMS-MS
    • DOI 10.1021/ac071575i
    • Trimpin, S., Plasencia, M., Isailovic, D., and Clemmer, D.E. (2007) Resolving oligomers from fully grown polymers with IMS-MS. Anal. Chem., 79: 7965-7974. (Pubitemid 350059990)
    • (2007) Analytical Chemistry , vol.79 , Issue.21 , pp. 7965-7974
    • Trimpin, S.1    Plasencia, M.2    Isailovic, D.3    Clemmer, D.E.4
  • 267
    • 57449102934 scopus 로고    scopus 로고
    • Ion mobility spectrometry/mass spectrometry snapshots for assessing the molecular compositions of complex polymeric systems
    • Trimpin, S. and Clemmer, D.E. (2008) Ion mobility spectrometry/mass spectrometry snapshots for assessing the molecular compositions of complex polymeric systems. Anal. Chem., 80: 9073-9083.
    • (2008) Anal. Chem. , vol.80 , pp. 9073-9083
    • Trimpin, S.1    Clemmer, D.E.2
  • 268
    • 78650494029 scopus 로고    scopus 로고
    • Highresolution ion mobility spectrometry-mass spectrometry on poly(methyl methacrylate)
    • Song, J., Grun, C.H., Heeren, R.M., Janssen, H.G., and van den Brink, O.F. (2010) Highresolution ion mobility spectrometry-mass spectrometry on poly(methyl methacrylate). Angew. Chem. Int. Ed., 49: 1-5.
    • (2010) Angew. Chem. Int. Ed. , vol.49 , pp. 1-5
    • Song, J.1    Grun, C.H.2    Heeren, R.M.3    Janssen, H.G.4    Van Den Brink, O.F.5
  • 269
    • 58149115083 scopus 로고    scopus 로고
    • Structural analysis of synthetic polymer mixtures using ion mobility and tandem mass spectrometry
    • Hilton, G.R., Jackson, A.T., Thalassinos, K., and Scrivens, J.H. (2008) Structural analysis of synthetic polymer mixtures using ion mobility and tandem mass spectrometry. Anal. Chem., 80: 9720-9725.
    • (2008) Anal. Chem. , vol.80 , pp. 9720-9725
    • Hilton, G.R.1    Jackson, A.T.2    Thalassinos, K.3    Scrivens, J.H.4
  • 270
    • 33847682262 scopus 로고    scopus 로고
    • Characterization of large fullerenes in single-wall carbon nanotube production by ion mobility mass spectrometry
    • DOI 10.1021/jp063649k
    • Scott, C.D., Ugarov, M., Hauge, R.H., Sosa, E.D., Arepalli, S., Schultz, J.A., and Yowell, L. (2007) Characterization of large fullerenes in single-wall carbon nanotube production by ion mobility mass spectrometry. J. Phys. Chem. C, 111: 36-44. (Pubitemid 46353191)
    • (2007) Journal of Physical Chemistry C , vol.111 , Issue.1 , pp. 36-44
    • Scott, C.D.1    Ugarov, M.2    Hauge, R.H.3    Sosa, E.D.4    Arepalli, S.5    Schultz, J.A.6    Yowell, L.7
  • 271
    • 77950455650 scopus 로고    scopus 로고
    • Surface fragmentation of complexes from thiolate protected gold nanoparticles by ion mobility-mass spectrometry
    • Harkness, K.M., Fenn, L.S., Cliffel, D.E., and McLean, J.A. (2010) Surface fragmentation of complexes from thiolate protected gold nanoparticles by ion mobility-mass spectrometry. Anal. Chem., 82: 3061-3066.
    • (2010) Anal. Chem. , vol.82 , pp. 3061-3066
    • Harkness, K.M.1    Fenn, L.S.2    Cliffel, D.E.3    McLean, J.A.4
  • 272
    • 34248141311 scopus 로고    scopus 로고
    • Analysis of nitrosamines by capillary electrospray-high-field asymmetric waveform ion mobility spectrometry-MS with programmed compensation voltage
    • Liu, X., Zhao,Y.Y., Chan, K.,Hrudey, S.E., Li, X.F., and Li, J.J. (2007) Analysis of nitrosamines by capillary electrospray-high-field asymmetric waveform ion mobility spectrometry-MS with programmed compensation voltage. Electrophoresis, 28: 1327-1334.
    • (2007) Electrophoresis , vol.28 , pp. 1327-1334
    • Zhaoy, L.X.1    Chan, K.2    Hrudey, S.E.3    Li, X.F.4    Li, J.J.5
  • 273
    • 62549096857 scopus 로고    scopus 로고
    • Combined utilization of ion mobility and ultra-high-resolution mass spectrometry to identify multiply charged constituents in natural organic matter
    • Gaspar, A., Kunenkov, E.V., Lock, R., Desor,M., Perminova, I., and Schmitt-Kopplin, P. (2009) Combined utilization of ion mobility and ultra-high-resolution mass spectrometry to identify multiply charged constituents in natural organic matter. Rapid Comm. Mass Spectrom., 23: 683-688.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 683-688
    • Gaspar, A.1    Kunenkov, E.V.2    Desorm, L.R.3    Perminova, I.4    Schmitt-Kopplin, P.5
  • 274
    • 56449122869 scopus 로고    scopus 로고
    • Molecular weight distributions of asphaltenes and deasphaltened oils studied by laser desorption ionization and ion mobility mass spectrometry
    • Becker, C., Qian, K.N., and Russell, D.H. (2008) Molecular weight distributions of asphaltenes and deasphaltened oils studied by laser desorption ionization and ion mobility mass spectrometry. Anal. Chem., 80: 8592-8597.
    • (2008) Anal. Chem. , vol.80 , pp. 8592-8597
    • Becker, C.1    Qian, K.N.2    Russell, D.H.3
  • 276
    • 69949160685 scopus 로고    scopus 로고
    • Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-acetonitrile nanodrops
    • Hogan, C.J., Jr. and Fernandez de la Mora, J. (2009) Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-acetonitrile nanodrops. Phys. Chem. Chem. Phys., 11: 8079-8090.
    • (2009) Phys. Chem. Chem. Phys. , vol.11 , pp. 8079-8090
    • Hogan Jr., C.J.1    Fernandez De La Mora, J.2
  • 279
    • 77955049296 scopus 로고    scopus 로고
    • Characterization of an ion mobility-multiplexed collision-induced dissociation-tandem time-of-flight mass spectrometry approach
    • Ibrahim, Y.M., Prior, D.C., Baker, E.S., Smith, R.D., and Belov, M.E. (2010) Characterization of an ion mobility-multiplexed collision-induced dissociation-tandem time-of-flight mass spectrometry approach. Int. J. Mass Spectrom., 293: 34-44.
    • (2010) Int. J. Mass Spectrom. , vol.293 , pp. 34-44
    • Ibrahim, Y.M.1    Prior, D.C.2    Baker, E.S.3    Smith, R.D.4    Belov, M.E.5
  • 280
    • 40249108399 scopus 로고    scopus 로고
    • Simultaneous fragmentation of multiple ions using IMS drift time dependent collision energies
    • Baker, E.S., Tang, K., Danielson, W.F., Prior, D.C., and Smith, R.D. (2008) Simultaneous fragmentation of multiple ions using IMS drift time dependent collision energies. J. Am. Soc. Mass Spectrom., 19: 411-419.
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 411-419
    • Baker, E.S.1    Tang, K.2    Danielson, W.F.3    Prior, D.C.4    Smith, R.D.5
  • 281
    • 41049113428 scopus 로고    scopus 로고
    • Evidence for structural variants of a- and b-type peptide fragment ions using combined ion mobility/mass spectrometry
    • Riba-Garcia, I., Giles, K., Bateman, R.H., and Gaskell, S.J. (2008) Evidence for structural variants of a- and b-type peptide fragment ions using combined ion mobility/mass spectrometry. J. Am. Soc. Mass Spectrom., 19: 609-613.
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 609-613
    • Riba-Garcia, I.1    Giles, K.2    Bateman, R.H.3    Gaskell, S.J.4
  • 282
    • 70349137136 scopus 로고    scopus 로고
    • High-field asymmetric waveform ion mobility spectrometry for determining the location of in-source collision-induced dissociation in electrospray ionization mass spectrometry
    • Xia, Y.Q. and Jemal,M. (2009) High-field asymmetric waveform ion mobility spectrometry for determining the location of in-source collision-induced dissociation in electrospray ionization mass spectrometry. Anal. Chem., 81: 7839-7843.
    • (2009) Anal. Chem. , vol.81 , pp. 7839-7843
    • Xia, Y.Q.1    Jemal, M.2
  • 283
    • 33750629515 scopus 로고    scopus 로고
    • A novel surface-induced dissociation instrument for ion mobility-time-of-flight mass spectrometry
    • Sun, W., May, J., and Russell, D. (2007) A novel surface-induced dissociation instrument for ion mobility-time-of-flight mass spectrometry. Int. J. Mass Spectrom., 259: 79-86.
    • (2007) Int. J. Mass Spectrom. , vol.259 , pp. 79-86
    • Sun, W.1    May, J.2    Russell, D.3
  • 284
    • 70349757011 scopus 로고    scopus 로고
    • A dual time-of-flight apparatus for an ion mobility-surface-induced dissociation-mass spectrometer for high-throughput peptide sequencing
    • Sun, W., May, J.C., Gillig, K.J., and Russell, D.H. (2009) A dual time-of-flight apparatus for an ion mobility-surface-induced dissociation-mass spectrometer for high-throughput peptide sequencing. Int. J. Mass Spectrom., 287: 39-45.
    • (2009) Int. J. Mass Spectrom. , vol.287 , pp. 39-45
    • Sun, W.1    May, J.C.2    Gillig, K.J.3    Russell, D.H.4
  • 285
    • 77954794218 scopus 로고    scopus 로고
    • Identifying drug metallation sites on peptides using electron transfer dissociation (ETD), collision induced dissociation (CID) and ion mobility-mass spectrometry (IM-MS)
    • Williams, J.P., Brown, J.M., Campuzano, I., and Sadler, P.J. (2010) Identifying drug metallation sites on peptides using electron transfer dissociation (ETD), collision induced dissociation (CID) and ion mobility-mass spectrometry (IM-MS). Chem. Comm., 46: 5458-5460.
    • (2010) Chem. Comm. , vol.46 , pp. 5458-5460
    • Williams, J.P.1    Brown, J.M.2    Campuzano, I.3    Sadler, P.J.4
  • 286
    • 34548049977 scopus 로고    scopus 로고
    • Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS)
    • DOI 10.1039/b706039d
    • Kolakowski, B.M. and Mester, Z. (2007) Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS). Analyst, 132: 842-864. (Pubitemid 47283703)
    • (2007) Analyst , vol.132 , Issue.9 , pp. 842-864
    • Kolakowski, B.M.1    Mester, Z.2
  • 287
    • 50649106398 scopus 로고    scopus 로고
    • Ion mobility spectrometry: Ion source development and applications in physical and biological sciences
    • Guharay, S.K., Dwivedi, P., and Hill, H.H. (2008) Ion mobility spectrometry: Ion source development and applications in physical and biological sciences. IEEE Trans. Plasma Sci., 36: 1458-1470.
    • (2008) IEEE Trans. Plasma Sci. , vol.36 , pp. 1458-1470
    • Guharay, S.K.1    Dwivedi, P.2    Hill, H.H.3
  • 290
    • 40649112609 scopus 로고    scopus 로고
    • A review on the application of high-field asymmetric waveform ion mobility spectrometry (FAIMS) in drug discovery
    • DOI 10.1002/rcm.3416
    • Hatsis, P. and Kapron, J.T. (2008) A review on the application of high-field asymmetric waveform ion mobility spectrometry (FAIMS) in drug discovery. Rapid Comm. Mass Spectrom., 22: 735-738. (Pubitemid 351373957)
    • (2008) Rapid Communications in Mass Spectrometry , vol.22 , Issue.5 , pp. 735-738
    • Hatsis, P.1    Kapron, J.T.2
  • 291
    • 41149098586 scopus 로고    scopus 로고
    • Analysis of bio-processes using ion mobility spectrometry
    • DOI 10.1002/elsc.200720221
    • Vautz,W. and Baumbach, J.I. (2008) Analysis of bio-processes using ion mobility spectrometry. Eng. Life Sci., 8: 19-25. (Pubitemid 351425137)
    • (2008) Engineering in Life Sciences , vol.8 , Issue.1 , pp. 19-25
    • Vautz, W.1    Baumbach, J.I.2
  • 293
    • 33746553778 scopus 로고    scopus 로고
    • Application of ion mobility spectrometry in cases of forensic interest
    • DOI 10.1016/j.forsciint.2006.03.032, PII S0379073806003501
    • Keller, T., Keller, A., Tutsch-Bauer, E., and Monticelli, F. (2006) Application of ion mobility spectrometry in cases of forensic interest. Forensic Sci. Int., 161: 130-140. (Pubitemid 44142903)
    • (2006) Forensic Science International , vol.161 , Issue.2-3 , pp. 130-140
    • Keller, T.1    Keller, A.2    Tutsch-Bauer, E.3    Monticelli, F.4
  • 295
    • 74449083521 scopus 로고    scopus 로고
    • Detection of explosives by positive corona discharge ion mobility spectrometry
    • Tabrizchi, M. and ILbeigi, V. (2010) Detection of explosives by positive corona discharge ion mobility spectrometry. J. Hazard. Mater., 176: 692-696.
    • (2010) J. Hazard. Mater. , vol.176 , pp. 692-696
    • Tabrizchi, M.1    Ilbeigi, V.2
  • 296
    • 67649792042 scopus 로고    scopus 로고
    • Headspace-solid-phase microextraction using a dodecylsulfate-doped polypyrrole film coupled to ion mobility spectrometry for analysis methyl tert-butyl ether in water and gasoline
    • Alizadeh, N., Jafari, M., and Mohammadi, A. (2009) Headspace-solid-phase microextraction using a dodecylsulfate-doped polypyrrole film coupled to ion mobility spectrometry for analysis methyl tert-butyl ether in water and gasoline. J. Hazard. Mater., 169: 861-867.
    • (2009) J. Hazard. Mater. , vol.169 , pp. 861-867
    • Alizadeh, N.1    Jafari, M.2    Mohammadi, A.3
  • 297
    • 50149103384 scopus 로고    scopus 로고
    • Direct determination of ammoniacal nitrogen in water samples using corona discharge ion mobility spectrometry
    • Jafari, M.T. and Khayamian, T. (2008) Direct determination of ammoniacal nitrogen in water samples using corona discharge ion mobility spectrometry. Talanta, 76: 1189-1193.
    • (2008) Talanta , vol.76 , pp. 1189-1193
    • Jafari, M.T.1    Khayamian, T.2
  • 298
    • 71449108380 scopus 로고    scopus 로고
    • Detection of microbial volatile organic compounds (MVOCs) by ion-mobility spectrometry
    • Tiebe, C., Miessner, H., Koch, B., and Hubert, T. (2009) Detection of microbial volatile organic compounds (MVOCs) by ion-mobility spectrometry. Anal. Bioanal. Chem., 395: 2313-2323.
    • (2009) Anal. Bioanal. Chem. , vol.395 , pp. 2313-2323
    • Tiebe, C.1    Miessner, H.2    Koch, B.3    Hubert, T.4
  • 299
    • 73949108655 scopus 로고    scopus 로고
    • Comparative measurements of toxic industrial compounds with a differential mobility spectrometer and a time of flight ion mobility spectrometer
    • Ungethüm, B., Walte, A., Münchmeyer, W., and Matz, G. (2009) Comparative measurements of toxic industrial compounds with a differential mobility spectrometer and a time of flight ion mobility spectrometer. Int. J. Ion. Mobil. Spectrom., 12: 131-137.
    • (2009) Int. J. Ion. Mobil. Spectrom. , vol.12 , pp. 131-137
    • Ungethüm, B.1    Walte, A.2    Münchmeyer, W.3    Matz, G.4
  • 300
    • 33846046384 scopus 로고    scopus 로고
    • Detection of sulfur-free odorants in natural gas using ion mobility spectrometry
    • DOI 10.1039/b613951e
    • Ruzsanyi, V., Sielemann, S., and Baumbach, J.I. (2007) Detection of sulfur-free odorants in natural gas using ion mobility spectrometry. J. Environ. Monit., 9: 61-65. (Pubitemid 46072468)
    • (2007) Journal of Environmental Monitoring , vol.9 , Issue.1 , pp. 61-65
    • Ruzsanyi, V.1    Sielemann, S.2    Baumbach, J.I.3
  • 302
    • 70350077806 scopus 로고    scopus 로고
    • Ion mobility spectrometry for the rapid analysis of over-the-counter drugs and beverages
    • Fernández-Maestre, R. and Hill, H. (2009) Ion mobility spectrometry for the rapid analysis of over-the-counter drugs and beverages. Int. J. Ion. Mobil. Spectrom., 12: 91-102.
    • (2009) Int. J. Ion. Mobil. Spectrom. , vol.12 , pp. 91-102
    • Fernández-Maestre, R.1    Hill, H.2
  • 303
    • 33845693775 scopus 로고    scopus 로고
    • Analysis of pharmaceutical formulations using atmospheric pressure ion mobility spectrometry combined with liquid chromatography and nano-electrospray ionisation
    • DOI 10.1039/b612796g
    • Budimir, N., Weston, D.J., and Creaser, C.S. (2007) Analysis of pharmaceutical formulations using atmospheric pressure ion mobility spectrometry combined with liquid chromatography and nano-electrospray ionisation. Analyst, 132: 34-40. (Pubitemid 44968848)
    • (2007) Analyst , vol.132 , Issue.1 , pp. 34-40
    • Budimir, N.1    Weston, D.J.2    Creaser, C.S.3
  • 304
    • 61449137706 scopus 로고    scopus 로고
    • Use of ion mobility spectroscopy with an ultraviolet ionization source as a vanguard screening system for the detection and determination of acetone in urine as a biomarker for cow and human diseases
    • Garrido-Delgado, R., Arce, L., Perez-Marin, C.C., and Valcarcel,M. (2009) Use of ion mobility spectroscopy with an ultraviolet ionization source as a vanguard screening system for the detection and determination of acetone in urine as a biomarker for cow and human diseases. Talanta, 78: 863-868.
    • (2009) Talanta , vol.78 , pp. 863-868
    • Garrido-Delgado, R.1    Arce, L.2    Perez-Marin, C.C.3    Valcarcel, M.4
  • 305
    • 71949124565 scopus 로고    scopus 로고
    • Online nanoelectrospray/high-field asymmetric waveform ion mobility
    • Hatsis, P., Valaskovic, G., and Wu, J.T. (2009) Online nanoelectrospray/high-field asymmetric waveform ion mobility spectrometry as a potential tool for discovery pharmaceutical bioanalysis. Rapid Comm. Mass Spectrom., 23: 3736-3742.
    • (2009) Rapid Comm. Mass Spectrom. , vol.23 , pp. 3736-3742
    • Hatsis, P.1    Valaskovic, G.2    Wu, J.T.3
  • 308
    • 67549092961 scopus 로고    scopus 로고
    • Rapid analysis of captopril in human plasma and pharmaceutical preparations by headspace solid phase microextraction based on polypyrrole film coupled to ion mobility spectrometry
    • Karimi, A. and Alizadeh, N. (2009) Rapid analysis of captopril in human plasma and pharmaceutical preparations by headspace solid phase microextraction based on polypyrrole film coupled to ion mobility spectrometry. Talanta, 79: 479-485.
    • (2009) Talanta , vol.79 , pp. 479-485
    • Karimi, A.1    Alizadeh, N.2
  • 309
    • 77953376642 scopus 로고    scopus 로고
    • Application of FAIMS to anabolic androgenic steroids in sport drug testing
    • Guddat, S., Thevis, M., Kapron, J., Thomas, A., and Schanzer,W. (2009) Application of FAIMS to anabolic androgenic steroids in sport drug testing. Drug Test. Anal., 1: 545-553.
    • (2009) Drug Test. Anal. , vol.1 , pp. 545-553
    • Guddat, S.1    Thevis, M.2    Kapron, J.3    Thomas, A.4    Schanzer, W.5
  • 310
    • 33751189820 scopus 로고    scopus 로고
    • Determination of veterinary drug residues in chicken meat using corona discharge ion mobility spectrometry
    • DOI 10.1016/j.aca.2006.08.005, PII S0003267006017004
    • Jafari, M.T., Khayamian, T., Shaer, V., and Zarei, N. (2007) Determination of veterinary drug residues in chicken meat using corona discharge ion mobility spectrometry. Anal. Chim. Acta, 581: 147-153. (Pubitemid 44779509)
    • (2007) Analytica Chimica Acta , vol.581 , Issue.1 , pp. 147-153
    • Jafari, M.T.1    Khayamian, T.2    Shaer, V.3    Zarei, N.4
  • 311
    • 77949286104 scopus 로고    scopus 로고
    • Analysis of biogenic amines using corona discharge ion mobility spectrometry
    • Hashemian, Z., Mardihallaj, A., and Khayamian, T. (2010) Analysis of biogenic amines using corona discharge ion mobility spectrometry. Talanta, 81: 1081-1087.
    • (2010) Talanta , vol.81 , pp. 1081-1087
    • Hashemian, Z.1    Mardihallaj, A.2    Khayamian, T.3
  • 312
    • 67349177730 scopus 로고    scopus 로고
    • Detection of volatile metabolites of Escherichia coli by multi capillary column coupled ion mobility spectrometry
    • Maddula, S., Blank, L.M., Schmid, A., and Baumbach, J.I. (2009) Detection of volatile metabolites of Escherichia coli by multi capillary column coupled ion mobility spectrometry. Anal. Bioanal. Chem., 394: 791-800.
    • (2009) Anal. Bioanal. Chem. , vol.394 , pp. 791-800
    • Maddula, S.1    Blank, L.M.2    Schmid, A.3    Baumbach, J.I.4
  • 313
    • 77954087702 scopus 로고    scopus 로고
    • Investigation of gaseous metabolites from moulds by ion mobility spectrometry (IMS) and gas chromatography-mass spectrometry (GC-MS)
    • Tiebe, C., Hübert, T., Koch, B., Ritter, U., and Stephan, I. (2010) Investigation of gaseous metabolites from moulds by ion mobility spectrometry (IMS) and gas chromatography-mass spectrometry (GC-MS). Int. J. Ion. Mobil. Spectrom., 13: 17-24.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 17-24
    • Tiebe, C.1    Hübert, T.2    Koch, B.3    Ritter, U.4    Stephan, I.5
  • 314
    • 67650032115 scopus 로고    scopus 로고
    • Ion mobility spectrometry coupled with multi-capillary columns for metabolic profiling of human breath
    • Baumbach, J.I. (2009) Ion mobility spectrometry coupled with multi-capillary columns for metabolic profiling of human breath. J. Breath. Res., 3: 1-16.
    • (2009) J. Breath. Res. , vol.3 , pp. 1-16
    • Baumbach, J.I.1
  • 315
    • 60549086913 scopus 로고    scopus 로고
    • Determination of volatile organic compounds in exhaled breath by ion mobility spectrometry
    • Ulanowska, A., Ligor, M., Amann, A., and Buszewski, B. (2008) Determination of volatile organic compounds in exhaled breath by ion mobility spectrometry. Chemia Analityczna, 53: 953-965.
    • (2008) Chemia Analityczna , vol.53 , pp. 953-965
    • Ulanowska, A.1    Ligor, M.2    Amann, A.3    Buszewski, B.4
  • 316
    • 71749099575 scopus 로고    scopus 로고
    • Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry
    • Perl, T., Carstens, E., Hirn, A., Quintel, M., Vautz, W., Nolte, J., and Junger, M. (2009) Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry. Br. J. Anaesth., 103: 822-827.
    • (2009) Br. J. Anaesth. , vol.103 , pp. 822-827
    • Perl, T.1    Carstens, E.2    Hirn, A.3    Quintel, M.4    Vautz, W.5    Nolte, J.6    Junger, M.7
  • 317
    • 77949637451 scopus 로고    scopus 로고
    • Analyses of mouse breath with ion mobility spectrometry: A feasibility study
    • Vautz, W., Nolte, J., Bufe, A., Baumbach, J.I., and Peters, M. (2010) Analyses of mouse breath with ion mobility spectrometry: a feasibility study. J. Appl. Physiol., 108: 697-704.
    • (2010) J. Appl. Physiol. , vol.108 , pp. 697-704
    • Vautz, W.1    Nolte, J.2    Bufe, A.3    Baumbach, J.I.4    Peters, M.5
  • 318
    • 77951294822 scopus 로고    scopus 로고
    • Identification of volatile chemical signatures from plastic explosives bySPME-GC/MS and detection by ion mobility spectrometry
    • Lai, H., Leung, A., Magee, M., and Almirall, J.R. (2010) Identification of volatile chemical signatures from plastic explosives bySPME-GC/MS and detection by ion mobility spectrometry. Anal. Bioanal. Chem., 396: 2997-3007.
    • (2010) Anal. Bioanal. Chem. , vol.396 , pp. 2997-3007
    • Lai, H.1    Leung, A.2    Magee, M.3    Almirall, J.R.4
  • 319
    • 29944433490 scopus 로고    scopus 로고
    • Closed tube sample introduction for gas chromatography - Ion mobility spectrometry analysis of water contaminated with a chemical warfare agent surrogate compound
    • DOI 10.1016/j.aca.2005.09.031, PII S0003267005015655
    • Erickson, R.P., Tripathi, A., Maswadeh, W.M., Snyder, A.P., and Smith, P.A. (2006) Closed tube sample introduction for gas chromatography-ion mobility spectrometry analysis of water contaminated with a chemical warfare agent surrogate compound. Anal. Chim. Acta, 556: 455-461. (Pubitemid 43042569)
    • (2006) Analytica Chimica Acta , vol.556 , Issue.2 , pp. 455-461
    • Erickson, R.P.1    Tripathi, A.2    Maswadeh, W.M.3    Snyder, A.P.4    Smith, P.A.5
  • 320
    • 33645005760 scopus 로고    scopus 로고
    • Detection of emissions from surfaces using ion mobility spectrometry
    • Vautz,W., Baumbach, J.I., and Uhde, E. (2006) Detection of emissions from surfaces using ion mobility spectrometry. Anal. Bioanal. Chem., 384: 980-986.
    • (2006) Anal. Bioanal. Chem. , vol.384 , pp. 980-986
    • Vautz, W.1    Baumbach, J.I.2    Uhde, E.3
  • 321
    • 73949124267 scopus 로고    scopus 로고
    • Determination of volatile organic compounds by solid-phase microextraction - Gas chromatography-differential mobility spectrometry
    • Telgheder, U., Malinowski, M., and Jochmann, M. (2009) Determination of volatile organic compounds by solid-phase microextraction - Gas chromatography-differential mobility spectrometry. Int. J. Ion. Mobil. Spectrom., 12: 123-130.
    • (2009) Int. J. Ion. Mobil. Spectrom. , vol.12 , pp. 123-130
    • Telgheder, U.1    Malinowski, M.2    Jochmann, M.3
  • 322
    • 70350053269 scopus 로고    scopus 로고
    • Quantitative determination of n-alkanethiols in air and in a blended gas mixture of methane with air by gas chromatography/differential mobility spectrometry
    • Nazarov, E., Miller, R., Krylov, E., Stone, J., and Eiceman, G. (2009) Quantitative determination of n-alkanethiols in air and in a blended gas mixture of methane with air by gas chromatography/differential mobility spectrometry. Int. J. Ion. Mobil. Spectrom., 12: 81-90.
    • (2009) Int. J. Ion. Mobil. Spectrom. , vol.12 , pp. 81-90
    • Nazarov, E.1    Miller, R.2    Krylov, E.3    Stone, J.4    Eiceman, G.5
  • 323
    • 78649905330 scopus 로고    scopus 로고
    • Fast gas chromatography- differential mobility spectrometry of explosives from TATP to tetryl without gas atmosphere modifiers
    • Cagan, A., Schmidt, H., Rodriguez, J., and Eiceman, G. (2010) Fast gas chromatography- differential mobility spectrometry of explosives from TATP to tetryl without gas atmosphere modifiers. Int. J. Ion. Mobil. Spectrom., 13: 157-165.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 157-165
    • Cagan, A.1    Schmidt, H.2    Rodriguez, J.3    Eiceman, G.4
  • 324
    • 34548570101 scopus 로고    scopus 로고
    • Forensic application of gas chromatography-differential mobility spectrometry with two-way classification of ignitable liquids from fire debris
    • DOI 10.1021/ac0707028
    • Lu, Y. and Harrington, P.B. (2007) Forensic application of gas chromatography-differential mobility spectrometry with two-way classification of ignitable liquids from fire debris. Anal. Chem., 79: 6752-6759. (Pubitemid 47395063)
    • (2007) Analytical Chemistry , vol.79 , Issue.17 , pp. 6752-6759
    • Lu, Y.1    Harrington, P.B.2
  • 325
    • 77955232157 scopus 로고    scopus 로고
    • Rapid determination of alcohols in human saliva by gas chromatography differential mobility spectrometry following selective membrane extraction
    • Bocos-Bintintan, V., Moll, V., Flanagan, R., and Thomas, C. (2010) Rapid determination of alcohols in human saliva by gas chromatography differential mobility spectrometry following selective membrane extraction. Int. J. Ion. Mobil. Spectrom., 13: 55-63.
    • (2010) Int. J. Ion. Mobil. Spectrom. , vol.13 , pp. 55-63
    • Bocos-Bintintan, V.1    Moll, V.2    Flanagan, R.3    Thomas, C.4
  • 326
    • 76749130199 scopus 로고    scopus 로고
    • Non-invasive metabolomic analysis of breath using differential mobility spectrometry in patients with chronic obstructive pulmonary disease and healthy smokers
    • Basanta, M., Jarvis, R.M., Xu, Y., Blackburn, G., Tal-Singer, R., Woodcock, A., Singh, D., Goodacre, R., Thomas, C.L.P., and Fowler, S.J. (2010) Non-invasive metabolomic analysis of breath using differential mobility spectrometry in patients with chronic obstructive pulmonary disease and healthy smokers. Analyst, 135: 315-320.
    • (2010) Analyst , vol.135 , pp. 315-320
    • Basanta, M.1    Jarvis, R.M.2    Xu, Y.3    Blackburn, G.4    Tal-Singer, R.5    Woodcock, A.6    Singh, D.7    Goodacre, R.8    Thomas, C.L.P.9    Fowler, S.J.10
  • 327
    • 53149084443 scopus 로고    scopus 로고
    • Design-of-experiment optimization of exhaled breath condensate analysis using a miniature differential mobility spectrometer (DMS)
    • Molina, M.A., Zhao, W., Sankaran, S., Schivo, M., Kenyon, N.J., and Davis, C.E. (2008) Design-of-experiment optimization of exhaled breath condensate analysis using a miniature differential mobility spectrometer (DMS). Anal. Chim. Acta, 628: 155-161.
    • (2008) Anal. Chim. Acta , vol.628 , pp. 155-161
    • Molina, M.A.1    Zhao, W.2    Sankaran, S.3    Schivo, M.4    Kenyon, N.J.5    Davis, C.E.6
  • 328
    • 60649085640 scopus 로고    scopus 로고
    • Discrimination of bacteria using pyrolysis-gas chromatography- differential mobility spectrometry (Py-GC-DMS) and chemometrics
    • Cheung, W., Xu, Y., Thomas, C.L., and Goodacre, R. (2009) Discrimination of bacteria using pyrolysis-gas chromatography-differential mobility spectrometry (Py-GC-DMS) and chemometrics. Analyst, 134: 557-563.
    • (2009) Analyst , vol.134 , pp. 557-563
    • Cheung, W.1    Xu, Y.2    Thomas, C.L.3    Goodacre, R.4
  • 329
    • 34748925784 scopus 로고    scopus 로고
    • Analysis of bacteria by pyrolysis gas chromatography-differential mobility spectrometry and isolation of chemical components with a dependence on growth temperature
    • DOI 10.1039/b705929a
    • Prasad, S., Pierce, K.M., Schmidt,H., Rao, J.V.,Guth, R., Bader, S., Synovec, R.E., Smith,G.B., and Eiceman, G.A. (2007) Analysis of bacteria by pyrolysis gas chromatography-differential mobility spectrometry and isolation of chemical components with a dependence on growth temperature. Analyst, 132: 1031-1039. (Pubitemid 47479680)
    • (2007) Analyst , vol.132 , Issue.10 , pp. 1031-1039
    • Prasad, S.1    Pierce, K.M.2    Schmidt, H.3    Rao, J.V.4    Guth, R.5    Bader, S.6    Synovec, R.E.7    Smith, G.B.8    Eiceman, G.A.9
  • 330
    • 44049088748 scopus 로고    scopus 로고
    • Constituents with independence from growth temperature for bacteria using pyrolysis-gas chromatography/differential mobility spectrometry with analysis of variance and principal component analysis
    • DOI 10.1039/b716371a
    • Prasad, S., Pierce, K.M., Schmidt, H., Rao, J.V., Guth, R., Synovec, R.E., Smith, G.B., and Eiceman, G.A. (2008) Constituents with independence from growth temperature for bacteria using pyrolysis-gas chromatography/differential mobility spectrometry with analysis of variance and principal component analysis. Analyst, 133: 760-767. (Pubitemid 351713325)
    • (2008) Analyst , vol.133 , Issue.6 , pp. 760-767
    • Prasad, S.1    Pierce, K.M.2    Schmidt, H.3    Rao, J.V.4    Guth, R.5    Synovec, R.E.6    Smith, G.B.7    Eiceman, G.A.8
  • 331
    • 33847176616 scopus 로고    scopus 로고
    • Fuzzy rule-building expert system classification of fuel using solid-phase microextraction two-way gas chromatography differential mobility spectrometric data
    • Rearden, P., Harrington, P.B., Karnes, J.J., and Bunker, C.E. (2007) Fuzzy rule-building expert system classification of fuel using solid-phase microextraction two-way gas chromatography differential mobility spectrometric data. Anal. Chem., 79: 1485-1491.
    • (2007) Anal. Chem. , vol.79 , pp. 1485-1491
    • Rearden, P.1    Harrington, P.B.2    Karnes, J.J.3    Bunker, C.E.4
  • 332
    • 57649219979 scopus 로고    scopus 로고
    • The use of shift reagents in ion mobility-mass spectrometry: Studies on the complexation of an active pharmaceutical ingredient with polyethylene glycol excipients
    • Howdle, M.D., Eckers, C., Laures, A.M.F., and Creaser, C.S. (2009) The use of shift reagents in ion mobility-mass spectrometry: Studies on the complexation of an active pharmaceutical ingredient with polyethylene glycol excipients. J. Am. Soc. Mass Spectrom., 20: 1-9.
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , pp. 1-9
    • Howdle, M.D.1    Eckers, C.2    Laures, A.M.F.3    Creaser, C.S.4
  • 333
    • 33947724376 scopus 로고    scopus 로고
    • Design and performance of an atmospheric pressure ion mobility Fourier transform ion cyclotron resonance mass spectrometer
    • DOI 10.1002/rcm.2928
    • Tang, X.T., Bruce, J.E., and Hill, H.H. (2007) Design and performance of an atmospheric pressure ion mobility Fourier transform ion cyclotron resonance mass spectrometer. Rapid Comm. Mass Spectrom., 21: 1115-1122. (Pubitemid 46506564)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.7 , pp. 1115-1122
    • Tang, X.1    Bruce, J.E.2    Hill Jr., H.H.3
  • 334
    • 78349309108 scopus 로고    scopus 로고
    • A rapid analytical method for hair analysis using ambient pressure ion mobility mass spectrometry with electrospray ionization (ESI-IMMS)
    • Dwivedi, P. and Hill, H. (2008) A rapid analytical method for hair analysis using ambient pressure ion mobility mass spectrometry with electrospray ionization (ESI-IMMS). Int. J. Ion. Mobil. Spectrom., 11: 61-69.
    • (2008) Int. J. Ion. Mobil. Spectrom. , vol.11 , pp. 61-69
    • Dwivedi, P.1    Hill, H.2
  • 335
    • 44949240697 scopus 로고    scopus 로고
    • Terbutaline enantiomer separation and quantification by complexation and field asymmetric ion mobility spectrometry-tandem mass spectrometry
    • DOI 10.1021/ac702262k
    • Mie, A., Ray, A., Axelsson, B.O., Jornten-Karlsson, M., and Reimann, C.T. (2008) Terbutaline enantiomer separation and quantification by complexation and field asymmetric ion mobility spectrometry-tandem mass spectrometry. Anal. Chem., 80: 4133-4140. (Pubitemid 351812766)
    • (2008) Analytical Chemistry , vol.80 , Issue.11 , pp. 4133-4140
    • Mie, A.1    Ray, A.2    Axelsson, B.-O.3    Jornten-Karlsson, M.4    Reimann, C.T.5
  • 336
    • 70349628896 scopus 로고    scopus 로고
    • Ultrafast differential ion mobility spectrometry at extreme electric fields coupled to mass spectrometry
    • Shvartsburg, A.A., Tang, K.Q., Smith, R.D., Holden, M., Rush, M., Thompson, A., and Toutoungi, D. (2009) Ultrafast differential ion mobility spectrometry at extreme electric fields coupled to mass spectrometry. Anal. Chem., 81: 8048-8053.
    • (2009) Anal. Chem. , vol.81 , pp. 8048-8053
    • Shvartsburg, A.A.1    Tang, K.Q.2    Smith, R.D.3    Holden, M.4    Rush, M.5    Thompson, A.6    Toutoungi, D.7
  • 338
    • 33846811132 scopus 로고    scopus 로고
    • An investigation of the mobility separation of some peptide and protein ions using a new hybrid quadrupole/travelling wave IMS/oa-ToF instrument
    • Pringle, S., Giles, K., Wildgoose, J., Williams, J., Slade, S., Thalassinos, K., Bateman, R., Bowers, M., and Scrivens, J. (2007) An investigation of the mobility separation of some peptide and protein ions using a new hybrid quadrupole/travelling wave IMS/oa-ToF instrument. Int. J. Mass Spectrom., 261: 1-12.
    • (2007) Int. J. Mass Spectrom. , vol.261 , pp. 1-12
    • Pringle, S.1    Giles, K.2    Wildgoose, J.3    Williams, J.4    Slade, S.5    Thalassinos, K.6    Bateman, R.7    Bowers, M.8    Scrivens, J.9
  • 339
    • 70349741035 scopus 로고    scopus 로고
    • An ion mobility-mass spectrometry investigation of monocyte chemoattractant protein-1
    • Schenauer, M.R. and Leary, J.A. (2009) An ion mobility-mass spectrometry investigation of monocyte chemoattractant protein-1. Int. J. Mass Spectrom., 287: 70-76.
    • (2009) Int. J. Mass Spectrom. , vol.287 , pp. 70-76
    • Schenauer, M.R.1    Leary, J.A.2
  • 340
    • 58149477901 scopus 로고    scopus 로고
    • Characterization of phosphorylated peptides using traveling wave-based and drift cell ion mobility mass spectrometry
    • Thalassinos, K., Grabenauer, M., Slade, S.E., Hilton, G.R., Bowers, M.T., and Scrivens, J.H. (2009) Characterization of phosphorylated peptides using traveling wave-based and drift cell ion mobility mass spectrometry. Anal. Chem., 81: 248-254.
    • (2009) Anal. Chem. , vol.81 , pp. 248-254
    • Thalassinos, K.1    Grabenauer, M.2    Slade, S.E.3    Hilton, G.R.4    Bowers, M.T.5    Scrivens, J.H.6
  • 341
    • 77957784477 scopus 로고    scopus 로고
    • Integrating ion mobility mass spectrometry with molecular modelling to determine the architecture of multiprotein complexes
    • Politis, A., Park, A.Y., Hyung, S.J., Barsky, D., Ruotolo, B.T., and Robinson, C.V. (2010) Integrating ion mobility mass spectrometry with molecular modelling to determine the architecture of multiprotein complexes. PLos One, 5: 1-11.
    • (2010) PLos One , vol.5 , pp. 1-11
    • Politis, A.1    Park, A.Y.2    Hyung, S.J.3    Barsky, D.4    Ruotolo, B.T.5    Robinson, C.V.6
  • 342
    • 33947713437 scopus 로고    scopus 로고
    • Evaluating the utility of ion mobility separation in combination with high-pressure liquid chromatography/mass spectrometry to facilitate detection of trace impurities in formulated drug products
    • DOI 10.1002/rcm.2938
    • Eckers, C., Laures, A.M.F., Giles, K., Major, H., and Pringle, S. (2007) Evaluating the utility of ion mobility separation in combination with high-pressure liquid chromatography/mass spectrometry to facilitate detection of trace impurities in formulated drug products. Rapid Comm. Mass Spectrom., 21: 1255-1263. (Pubitemid 46506580)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.7 , pp. 1255-1263
    • Eckers, C.1    Laures, A.M.-F.2    Giles, K.3    Major, H.4    Pringle, S.5
  • 343
    • 35648957210 scopus 로고    scopus 로고
    • Ion mobility-mass spectrometry reveals long-lived, unfolded intermediates in the dissociation of protein complexes
    • DOI 10.1002/anie.200702161
    • Ruotolo, B.T.,Hyung, S.J.,Robinson, P.M.,Giles, K.,Bateman,R.H., andRobinson, C.V. (2007) Ion mobility-mass spectrometry reveals long-lived, unfolded intermediates in the dissociation of protein complexes. Angew. Chem. Int. Ed., 46: 8001-8004. (Pubitemid 350033476)
    • (2007) Angewandte Chemie - International Edition , vol.46 , Issue.42 , pp. 8001-8004
    • Ruotolo, B.T.1    Hyung, S.-J.2    Robinson, P.M.3    Giles, K.4    Bateman, R.H.5    Robinson, C.V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.