-
1
-
-
12944320855
-
HPLC-MS-based Methods for the Study of Metabonomics
-
Wilson I.D., Plumb R., Granger J., Major H., Williams R., and Lenz E.M. HPLC-MS-based Methods for the Study of Metabonomics. J. Chromatogr. B 817 (2005) 67-76
-
(2005)
J. Chromatogr. B
, vol.817
, pp. 67-76
-
-
Wilson, I.D.1
Plumb, R.2
Granger, J.3
Major, H.4
Williams, R.5
Lenz, E.M.6
-
2
-
-
33847377098
-
From Exogenous to Endogenous: The Inevitable Imprint of Mass Spectrometry in Metabolomics
-
Want E.J., Nordstrom A., Morita H., and Siudzak G. From Exogenous to Endogenous: The Inevitable Imprint of Mass Spectrometry in Metabolomics. J. Proteome Res. 6 (2007) 459-468
-
(2007)
J. Proteome Res.
, vol.6
, pp. 459-468
-
-
Want, E.J.1
Nordstrom, A.2
Morita, H.3
Siudzak, G.4
-
3
-
-
0041698335
-
High-Sensitivity Quantitation of Cabergoline and Pergolide Using a Triple-Quadrupole Mass Spectrometer with Enhanced Mass-Resolution Capabilities
-
Hughes N., Winnik W., Dunyach J., Amad M., Splendore M., and Paul G. High-Sensitivity Quantitation of Cabergoline and Pergolide Using a Triple-Quadrupole Mass Spectrometer with Enhanced Mass-Resolution Capabilities. J. Mass Spectrom. 38 (2003) 743-751
-
(2003)
J. Mass Spectrom.
, vol.38
, pp. 743-751
-
-
Hughes, N.1
Winnik, W.2
Dunyach, J.3
Amad, M.4
Splendore, M.5
Paul, G.6
-
4
-
-
33748168091
-
Electrospray Ion Source. Another Variation on the Free-Jet Theme
-
Yamashita M., and Fenn J.B. Electrospray Ion Source. Another Variation on the Free-Jet Theme. J. Phys. Chem. 88 (1984) 4451-4459
-
(1984)
J. Phys. Chem.
, vol.88
, pp. 4451-4459
-
-
Yamashita, M.1
Fenn, J.B.2
-
5
-
-
0024438708
-
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
-
Fenn J.B., Mann M., Meng C.K., Wong S.F., and Whitehouse C.M. Electrospray Ionization for Mass Spectrometry of Large Biomolecules. Science 246 (1989) 64-71
-
(1989)
Science
, vol.246
, pp. 64-71
-
-
Fenn, J.B.1
Mann, M.2
Meng, C.K.3
Wong, S.F.4
Whitehouse, C.M.5
-
6
-
-
0023455726
-
Ion Spray Interface for Combined Liquid Chromatography/Atmospheric Pressure Ionization Mass Spectrometry
-
Bruins A.P., Covey T.R., and Henion J.D. Ion Spray Interface for Combined Liquid Chromatography/Atmospheric Pressure Ionization Mass Spectrometry. Anal. Chem. 59 (1987) 2642-2646
-
(1987)
Anal. Chem.
, vol.59
, pp. 2642-2646
-
-
Bruins, A.P.1
Covey, T.R.2
Henion, J.D.3
-
7
-
-
0020903389
-
Direct Liquid Introduction/Thermospray Interface for Liquid Chromatography/Mass Spectrometry
-
Covey T., and Henion J. Direct Liquid Introduction/Thermospray Interface for Liquid Chromatography/Mass Spectrometry. Anal. Chem. 55 (1983) 2275-2280
-
(1983)
Anal. Chem.
, vol.55
, pp. 2275-2280
-
-
Covey, T.1
Henion, J.2
-
9
-
-
22744437139
-
Removal of Metabolite Interference during Liquid Chromatography/Tandem Mass Spectrometry Using High-Field Asymmetric Waveform Ion Mobility Spectrometry
-
Kapron J.T., Jemal M., Duncan G., Kolakowski B., and Purves R.W. Removal of Metabolite Interference during Liquid Chromatography/Tandem Mass Spectrometry Using High-Field Asymmetric Waveform Ion Mobility Spectrometry. Rapid Commun. Mass Spectrom. 19 (2005) 1-6
-
(2005)
Rapid Commun. Mass Spectrom.
, vol.19
, pp. 1-6
-
-
Kapron, J.T.1
Jemal, M.2
Duncan, G.3
Kolakowski, B.4
Purves, R.W.5
-
10
-
-
0000741268
-
A New Method of Separation of Multi-atomic Ions by Mobility at Atmospheric Pressure Using a High-Frequency Amplitude-Asymmetric Strong Electric Field
-
Buryakov I.A., Krylov E.V., Nazarov E.G., and Rasulev U.K. A New Method of Separation of Multi-atomic Ions by Mobility at Atmospheric Pressure Using a High-Frequency Amplitude-Asymmetric Strong Electric Field. Int. J. Mass Spectrom. Ion. Process. 128 (1993) 143-148
-
(1993)
Int. J. Mass Spectrom. Ion. Process.
, vol.128
, pp. 143-148
-
-
Buryakov, I.A.1
Krylov, E.V.2
Nazarov, E.G.3
Rasulev, U.K.4
-
11
-
-
0032324858
-
Mass Spectrometric Characterization of a High-Field Asymmetric Waveform Ion Mobility Spectrometer
-
Purves R.W., Guevremont R., Day S., Pipich C.W., and Matyjaszczyk M.S. Mass Spectrometric Characterization of a High-Field Asymmetric Waveform Ion Mobility Spectrometer. Rev. Sci. Instrum. 69 (1998) 4094-4105
-
(1998)
Rev. Sci. Instrum.
, vol.69
, pp. 4094-4105
-
-
Purves, R.W.1
Guevremont, R.2
Day, S.3
Pipich, C.W.4
Matyjaszczyk, M.S.5
-
12
-
-
0033168983
-
Electrospray Ionization-High Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometry
-
Purves R.W., and Guevremont R. Electrospray Ionization-High Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometry. Anal. Chem. 71 (1999) 2346-2357
-
(1999)
Anal. Chem.
, vol.71
, pp. 2346-2357
-
-
Purves, R.W.1
Guevremont, R.2
-
13
-
-
0035564254
-
Atmospheric Pressure Ion Trapping in a Tandem FAIMS-FAIMS Coupled to a TOFMS: Studies with Electrospray Generated Gramicidin S Ions
-
Guevremont R., Ding L., Ells B., Barnett D.A., and Purves R.W. Atmospheric Pressure Ion Trapping in a Tandem FAIMS-FAIMS Coupled to a TOFMS: Studies with Electrospray Generated Gramicidin S Ions. J. Am. Soc. Mass Spectrom. 12 (2001) 1320-1330
-
(2001)
J. Am. Soc. Mass Spectrom.
, vol.12
, pp. 1320-1330
-
-
Guevremont, R.1
Ding, L.2
Ells, B.3
Barnett, D.A.4
Purves, R.W.5
-
14
-
-
33746809833
-
Rapid Separation and Quantitative Analysis of Peptides Using a New Nanoelectrospray-Differential Mobility Spectrometer-Mass Spectrometer System
-
Levin D.S., Miller R.A., Nazarov E.G., and Vouros P. Rapid Separation and Quantitative Analysis of Peptides Using a New Nanoelectrospray-Differential Mobility Spectrometer-Mass Spectrometer System. Anal. Chem. 78 (2006) 5443-5452
-
(2006)
Anal. Chem.
, vol.78
, pp. 5443-5452
-
-
Levin, D.S.1
Miller, R.A.2
Nazarov, E.G.3
Vouros, P.4
-
15
-
-
26444441382
-
Two-Dimensional Gas-Phase Separations Coupled to Mass Spectrometry for Analysis of Complex Mixtures
-
Tang K., Li F., Shvartsburg A.A., Strittmatter E.F., and Smith R.D. Two-Dimensional Gas-Phase Separations Coupled to Mass Spectrometry for Analysis of Complex Mixtures. Anal. Chem. 77 (2005) 6381-6388
-
(2005)
Anal. Chem.
, vol.77
, pp. 6381-6388
-
-
Tang, K.1
Li, F.2
Shvartsburg, A.A.3
Strittmatter, E.F.4
Smith, R.D.5
-
16
-
-
33744949963
-
High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry Analyzers
-
Shvartsburg A.A., Li F., Tang K., and Smith R.D. High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry Analyzers. Anal. Chem. 78 (2006) 3706-3714
-
(2006)
Anal. Chem.
, vol.78
, pp. 3706-3714
-
-
Shvartsburg, A.A.1
Li, F.2
Tang, K.3
Smith, R.D.4
-
17
-
-
0000056838
-
Atmospheric Pressure Ion Focusing in a High-Field Asymmetric Waveform Ion Mobility Spectrometer
-
Guevremont R., and Purves R.W. Atmospheric Pressure Ion Focusing in a High-Field Asymmetric Waveform Ion Mobility Spectrometer. Rev. Sci. Instrum. 70 (1999) 1370-1383
-
(1999)
Rev. Sci. Instrum.
, vol.70
, pp. 1370-1383
-
-
Guevremont, R.1
Purves, R.W.2
-
18
-
-
0034307598
-
Detection of Nine Chlorinated and Brominated Haloacetic Acids at Part-per-trillion Levels Using ESI-FAIMS-MS
-
Ells B., Barnett D.A., Purves R.W., and Guevremont R. Detection of Nine Chlorinated and Brominated Haloacetic Acids at Part-per-trillion Levels Using ESI-FAIMS-MS. Anal. Chem. 72 (2000) 4555-4559
-
(2000)
Anal. Chem.
, vol.72
, pp. 4555-4559
-
-
Ells, B.1
Barnett, D.A.2
Purves, R.W.3
Guevremont, R.4
-
19
-
-
4043139965
-
Coupling Capillary Electrophoresis and High-Field Asymmetric Waveform Ion Mobility Spectrometry Mass Spectrometry for the Analysis of Complex Liposaccharides
-
Li J., Purves R.W., and Richards J.C. Coupling Capillary Electrophoresis and High-Field Asymmetric Waveform Ion Mobility Spectrometry Mass Spectrometry for the Analysis of Complex Liposaccharides. Anal. Chem. 76 (2004) 4676-4683
-
(2004)
Anal. Chem.
, vol.76
, pp. 4676-4683
-
-
Li, J.1
Purves, R.W.2
Richards, J.C.3
-
20
-
-
33646722849
-
Simultaneous Analysis of Prostanoids Using Liquid Chromatography/High-Field Asymmetric Waveform Ion Mobility Spectrometry/Tandem Mass Spectrometry (LC-FAIMS-MS/MS)
-
Kapron J.T., Wu J., Mauriala T., Clark P., Purves R.W., and Bateman K. Simultaneous Analysis of Prostanoids Using Liquid Chromatography/High-Field Asymmetric Waveform Ion Mobility Spectrometry/Tandem Mass Spectrometry (LC-FAIMS-MS/MS). Rapid Commun. Mass Spectrom. 20 (2006) 1-8
-
(2006)
Rapid Commun. Mass Spectrom.
, vol.20
, pp. 1-8
-
-
Kapron, J.T.1
Wu, J.2
Mauriala, T.3
Clark, P.4
Purves, R.W.5
Bateman, K.6
-
23
-
-
0034728308
-
Comparison of High-Field Ion Mobility Obtained from Drift Tubes and a FAIMS Apparatus
-
Viehland L.A., Guevremont R., Purves R.W., and Barnett D.A. Comparison of High-Field Ion Mobility Obtained from Drift Tubes and a FAIMS Apparatus. Int. J. Mass Spectrom. 197 (2000) 123-130
-
(2000)
Int. J. Mass Spectrom.
, vol.197
, pp. 123-130
-
-
Viehland, L.A.1
Guevremont, R.2
Purves, R.W.3
Barnett, D.A.4
-
24
-
-
0035875317
-
Calculation of Ion Mobilities from Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Mass Spectrometry Data
-
Guevremont R., Barnett D.A., Purves R.W., and Viehland L.A. Calculation of Ion Mobilities from Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Mass Spectrometry Data. J. Chem. Phys. 114 (2001) 10270-10277
-
(2001)
J. Chem. Phys.
, vol.114
, pp. 10270-10277
-
-
Guevremont, R.1
Barnett, D.A.2
Purves, R.W.3
Viehland, L.A.4
-
25
-
-
14744300128
-
Comparison of Experimental and Calculated Peak Shapes for Three Cylindrical Geometry FAIMS Prototypes of Differing Electrode Diameters
-
Guevremont R., and Purves R.W. Comparison of Experimental and Calculated Peak Shapes for Three Cylindrical Geometry FAIMS Prototypes of Differing Electrode Diameters. J. Am. Soc. Mass Spectrom. 16 (2005) 349-362
-
(2005)
J. Am. Soc. Mass Spectrom.
, vol.16
, pp. 349-362
-
-
Guevremont, R.1
Purves, R.W.2
-
26
-
-
33751295502
-
Field Asymmetric Waveform Ion Mobility Spectrometry Studies of Proteins: Dipole Alignment in Ion Mobility Spectrometry
-
Shvartsburg A.A., Bryskiewicz T., Purves R.W., Tang K., Guevremont R., and Smith R.D. Field Asymmetric Waveform Ion Mobility Spectrometry Studies of Proteins: Dipole Alignment in Ion Mobility Spectrometry. J. Phys. Chem. B 110 (2006) 21966-21980
-
(2006)
J. Phys. Chem. B
, vol.110
, pp. 21966-21980
-
-
Shvartsburg, A.A.1
Bryskiewicz, T.2
Purves, R.W.3
Tang, K.4
Guevremont, R.5
Smith, R.D.6
-
27
-
-
0035096864
-
Quantitation of Morphine and Codeine in Human Urine Using High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) with Mass Spectrometric Detection
-
McCooeye M.A., Ells B., Barnett D.A., Purves R.W., and Guevremont R. Quantitation of Morphine and Codeine in Human Urine Using High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) with Mass Spectrometric Detection. J. Anal. Toxicol. 25 (2001) 81-87
-
(2001)
J. Anal. Toxicol.
, vol.25
, pp. 81-87
-
-
McCooeye, M.A.1
Ells, B.2
Barnett, D.A.3
Purves, R.W.4
Guevremont, R.5
-
29
-
-
10644224548
-
Understanding and Designing Field Asymmetric Waveform Ion Mobility Separations in Gas Mixtures
-
Shvartsburg A., Tang K., and Smith R.D. Understanding and Designing Field Asymmetric Waveform Ion Mobility Separations in Gas Mixtures. Anal. Chem. 76 (2004) 7366-7374
-
(2004)
Anal. Chem.
, vol.76
, pp. 7366-7374
-
-
Shvartsburg, A.1
Tang, K.2
Smith, R.D.3
|