메뉴 건너뛰기




Volumn 11, Issue 3, 2007, Pages 143-159

Advances in Cochlear Implant Telemetry: Evoked Neural Responses, Electrical Field Imaging, and Technical Integrity

Author keywords

cochlear implant; deafness; evoked potentials; integrity; telemetry

Indexed keywords

ACTION POTENTIAL; AUDITORY STIMULATION; COCHLEA PROSTHESIS; COCHLEAR NERVE; ELECTRIC FIELD; ELECTROSTIMULATION; EVOKED RESPONSE; HEARING IMPAIRMENT; HUMAN; IMAGING; MONITORING; NERVE EXCITABILITY; NERVE STIMULATION; REVIEW; SOUND DETECTION; SPEECH; TELEMETRY;

EID: 34547851753     PISSN: 10847138     EISSN: None     Source Type: Journal    
DOI: 10.1177/1084713807304362     Document Type: Article
Times cited : (53)

References (59)
  • 3
    • 20444484790 scopus 로고    scopus 로고
    • Unraveling the electrically evoked compound action potential
    • Briaire JJ, Frijns Jhm. Unraveling the electrically evoked compound action potential. Hear Res. 2005; 205:143-156.
    • (2005) Hear Res , vol.205 , pp. 143-156
    • Briaire, J.J.1    Frijns, J.2
  • 4
    • 0032991110 scopus 로고    scopus 로고
    • The prognostic value of electrocochleography in severely hearing-impaired infants
    • Schoonhoven R., Lamore PJ, de Laat JA, Grote JJ The prognostic value of electrocochleography in severely hearing-impaired infants. Audiology. 1999;38:141-154.
    • (1999) Audiology. , vol.38 , pp. 141-154
    • Schoonhoven, R.1    Lamore, P.J.2    de Laat, J.A.3    Grote, J.J.4
  • 5
    • 1642350274 scopus 로고    scopus 로고
    • A new method for dealing with the stimulus artefact in electrically evoked compound action potential measurements
    • Klop Wmc, Hartlooper A., Briare JJ, Frijns Jhm. A new method for dealing with the stimulus artefact in electrically evoked compound action potential measurements. Acta Otolaryngol. 2004;124:137-143.
    • (2004) Acta Otolaryngol. , vol.124 , pp. 137-143
    • Wmc, K.1    Hartlooper, A.2    Briare, J.J.3    Frijns, J.4
  • 6
    • 33644484719 scopus 로고    scopus 로고
    • The electrically evoked whole nerve action potential
    • In: Cullington HE, ed. London, England: Whurr
    • Brown C. The electrically evoked whole nerve action potential. In: Cullington HE, ed. Cochlear Implants: Objective Measures. London, England: Whurr; 2003:96-129.
    • (2003) Cochlear Implants: Objective Measures , pp. 96-129
    • Brown, C.1
  • 7
    • 0020705605 scopus 로고
    • Acoustically derived auditory nerve action potential evoked by electrical stimulation: an estimation of the waveform of single unit contribution
    • Charlet de Sauvage R., Cazals Y., Erre JP, Aran JM Acoustically derived auditory nerve action potential evoked by electrical stimulation: an estimation of the waveform of single unit contribution. J Acoust Soc Am. 1983;73:616-627.
    • (1983) J Acoust Soc Am. , vol.73 , pp. 616-627
    • Charlet de Sauvage, R.1    Cazals, Y.2    Erre, J.P.3    Aran, J.M.4
  • 8
    • 0025109523 scopus 로고
    • Electrically evoked whole-nerve action potentials: data from human cochlear implant users
    • Brown CJ, Abbas PJ, Gantz B. Electrically evoked whole-nerve action potentials: data from human cochlear implant users. J Acoust Soc Am. 1990;88:1385-1391.
    • (1990) J Acoust Soc Am , vol.88 , pp. 1385-1391
    • Brown, C.J.1    Abbas, P.J.2    Gantz, B.3
  • 9
    • 0034113705 scopus 로고    scopus 로고
    • The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: data from adults
    • Brown CJ, Hughes ML, Luk B., Abbas PJ, Wolaver A., Gervais J. The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: data from adults. Ear Hear. 2000;21:151-163.
    • (2000) Ear Hear. , vol.21 , pp. 151-163
    • Brown, C.J.1    Hughes, M.L.2    Luk, B.3    Abbas, P.J.4    Wolaver, A.5    Gervais, J.6
  • 10
    • 19944431982 scopus 로고    scopus 로고
    • Evaluation of the neural response telemetry (NRT) capabilities of the nucleus research platform 8: initial results from the NRT trial
    • Battmer RD, Dillier N., Lai WK, et al. Evaluation of the neural response telemetry (NRT) capabilities of the nucleus research platform 8: initial results from the NRT trial. Int J Audiol. 2004;43:S10-S15.
    • (2004) Int J Audiol. , vol.43 , pp. S10-S15
    • Battmer, R.D.1    Dillier, N.2    Lai, W.K.3
  • 11
    • 2942713534 scopus 로고    scopus 로고
    • Automatic analysis of auditory nerve electrically evoked compound action potential with an artificial neural network
    • Charasse B., Thai-Van H, Chanal JM, Berger-Vachon C, Collet L. Automatic analysis of auditory nerve electrically evoked compound action potential with an artificial neural network. Artif Intell Med. 2004;31:221-229.
    • (2004) Artif Intell Med. , vol.31 , pp. 221-229
    • Charasse, B.1    Thai-Van, H.2    Chanal, J.M.3    Berger-Vachon, C.4    Collet, L.5
  • 12
    • 34247521841 scopus 로고    scopus 로고
    • AutoNRT™: an automated system that measures ECAP thresholds with the Nucleus(r) Freedom™ cochlear implant via machine intelligence
    • Epub 2006 Aug 22.
    • Botros A., van Dijk B., Killian M. AutoNRT™: an automated system that measures ECAP thresholds with the Nucleus(r) Freedom™ cochlear implant via machine intelligence. Artif Intell Med. 2007;40:15-28. Epub 2006 Aug 22.
    • (2007) Artif Intell Med. , vol.40 , pp. 15-28
    • Botros, A.1    van Dijk, B.2    Killian, M.3
  • 13
    • 84997991812 scopus 로고    scopus 로고
    • A new stimulus for promonoty E-ABR
    • Paper presented at: 1993 Conference on implantable auditory prostheses; July 11-15, 1993; Smithfield, RI.
    • Marsh. A new stimulus for promonoty E-ABR. Paper presented at: 1993 Conference on implantable auditory prostheses; July 11-15, 1993; Smithfield, RI.
    • Marsh1
  • 14
    • 13144266699 scopus 로고    scopus 로고
    • Electrophysiologic and objective monitoring of the cochlear implant during surgery: implementation, audit and outcomes
    • Mason S. Electrophysiologic and objective monitoring of the cochlear implant during surgery: implementation, audit and outcomes. Int J Audiol. 2004;43:S33-S38.
    • (2004) Int J Audiol. , vol.43 , pp. S33-S38
    • Mason, S.1
  • 15
    • 2142755946 scopus 로고    scopus 로고
    • Effects of pulse rate on threshold and dynamic range in Clarion cochlear-implant users
    • Kreft HA, Donaldson GS, Nelson DA Effects of pulse rate on threshold and dynamic range in Clarion cochlear-implant users. J Acoust Soc Am. 2004;115(5Pt1): 1885-1888.
    • (2004) J Acoust Soc Am. , vol.115 , Issue.5 , pp. 1885-1888
    • Kreft, H.A.1    Donaldson, G.S.2    Nelson, D.A.3
  • 16
    • 0021790247 scopus 로고
    • Threshold and loudness functions for pulsatile stimulation of cochlear implants
    • Shannon RV Threshold and loudness functions for pulsatile stimulation of cochlear implants. Hear Res. 1985; 18:135-143.
    • (1985) Hear Res , vol.18 , pp. 135-143
    • Shannon, R.V.1
  • 17
    • 0030728304 scopus 로고    scopus 로고
    • Effect of high-frequency electrical stimulation of the auditory nerve in an animal model of cochlear implants
    • Vischer M., Haenggeli A., Zhang J., Pelizzone M., Hausler R., Rouiller EM Effect of high-frequency electrical stimulation of the auditory nerve in an animal model of cochlear implants. Am J Otol. 1997;18(6 Suppl.):S27-S29.
    • (1997) Am J Otol. , vol.18 , pp. S27-S29
    • Vischer, M.1    Haenggeli, A.2    Zhang, J.3    Pelizzone, M.4    Hausler, R.5    Rouiller, E.M.6
  • 18
    • 19944402544 scopus 로고    scopus 로고
    • Normative findings of electrically evoked compound action potential measurements using the neural response telemetry of the Nucleus CI24M cochlear implant system
    • Cafarelli-Dees D., Dillier N., Lai WK, et al. Normative findings of electrically evoked compound action potential measurements using the neural response telemetry of the Nucleus CI24M cochlear implant system. Audiol Neurootol. 2005;10:105-116.
    • (2005) Audiol Neurootol. , vol.10 , pp. 105-116
    • Cafarelli-Dees, D.1    Dillier, N.2    Lai, W.K.3
  • 19
    • 0034032485 scopus 로고    scopus 로고
    • Comparison of EAP thresholds with MAP levels in the nucleus 24 cochlear implant: data from children
    • Hughes ML, Brown CJ, Abbas PJ, Wolaver AA, Gervais JP Comparison of EAP thresholds with MAP levels in the nucleus 24 cochlear implant: data from children. Ear Hear. 2000;21:164-174.
    • (2000) Ear Hear. , vol.21 , pp. 164-174
    • Hughes, M.L.1    Brown, C.J.2    Abbas, P.J.3    Wolaver, A.A.4    Gervais, J.P.5
  • 20
    • 0034779532 scopus 로고    scopus 로고
    • Intra-operative recordings of electrically evoked auditory nerve action potentials in young children by use of neural response telemetry with the Nucleus CI24M cochlear implant
    • Mason SM, Cope Y., Garnham J., O'Donoghue GM, Gibbin KP Intra-operative recordings of electrically evoked auditory nerve action potentials in young children by use of neural response telemetry with the Nucleus CI24M cochlear implant. Br J Audiol. 2001;35:225-235.
    • (2001) Br J Audiol. , vol.35 , pp. 225-235
    • Mason, S.M.1    Cope, Y.2    Garnham, J.3    O'Donoghue, G.M.4    Gibbin, K.P.5
  • 21
    • 0036185977 scopus 로고    scopus 로고
    • A model of a nucleus 24 cochlear implant fitting protocol based on the electrically evoked whole nerve action potential
    • Franck KH A model of a nucleus 24 cochlear implant fitting protocol based on the electrically evoked whole nerve action potential. Ear Hear. 2002;23(1 Suppl):67S-71S.
    • (2002) Ear Hear. , vol.23 , pp. 67S-71S
    • Franck, K.H.1
  • 22
    • 0036208690 scopus 로고    scopus 로고
    • EAP recordings in ineraid patients—correlations with psychophysical measures and possible implications for patient fitting
    • Zimmerling MJ, Hochmair ES EAP recordings in ineraid patients—correlations with psychophysical measures and possible implications for patient fitting. Ear Hear. 2002;23:81-91.
    • (2002) Ear Hear. , vol.23 , pp. 81-91
    • Zimmerling, M.J.1    Hochmair, E.S.2
  • 23
    • 8844226063 scopus 로고    scopus 로고
    • Modeling the relationship between psychophysical perception and electrically evoked compound action potential threshold in young cochlear implant recipients: clinical implications for implant fitting
    • Thai-Van H., Truy E., Charasse B., et al. Modeling the relationship between psychophysical perception and electrically evoked compound action potential threshold in young cochlear implant recipients: clinical implications for implant fitting. Clin Neurophysiol. 2004;115: 2811-2824.
    • (2004) Clin Neurophysiol. , vol.115 , pp. 2811-2824
    • Thai-Van, H.1    Truy, E.2    Charasse, B.3
  • 24
    • 4944250520 scopus 로고    scopus 로고
    • Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children
    • Gordon KA, Papsin BC, Harrison RV Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children. Ear Hear. 2004;25:447-463.
    • (2004) Ear Hear. , vol.25 , pp. 447-463
    • Gordon, K.A.1    Papsin, B.C.2    Harrison, R.V.3
  • 25
    • 0036970158 scopus 로고    scopus 로고
    • Speech perception in nucleus C124M cochlear implant users with processor settings based on electrically evoked compound action potential thresholds
    • Smoorenburg GF, Willeboer C., van Dijk JE Speech perception in nucleus C124M cochlear implant users with processor settings based on electrically evoked compound action potential thresholds. Audiol Neurootol. 2002;7:335-347.
    • (2002) Audiol Neurootol. , vol.7 , pp. 335-347
    • Smoorenburg, G.F.1    Willeboer, C.2    van Dijk, J.E.3
  • 26
    • 23644440293 scopus 로고    scopus 로고
    • A different approach to using neural response telemetry for automated cochlear implant processor programming
    • McKay CM, Fewster L., Dawson P. A different approach to using neural response telemetry for automated cochlear implant processor programming. Ear Hear. 2005;26(4 Suppl.):38S-44S.
    • (2005) Ear Hear , vol.26 , pp. 38S-44S
    • McKay, C.M.1    Fewster, L.2    Dawson, P.3
  • 27
    • 0141729411 scopus 로고    scopus 로고
    • Clinical uses of electrically evoked auditory nerve and brainstem responses
    • Brown CJ Clinical uses of electrically evoked auditory nerve and brainstem responses. Curr Opin Otolaryngol Head Neck Surg. 2003;11:383-387.
    • (2003) Curr Opin Otolaryngol Head Neck Surg. , vol.11 , pp. 383-387
    • Brown, C.J.1
  • 28
    • 0036190006 scopus 로고    scopus 로고
    • Speech perception using maps based on neural response telemetry measures
    • Seyle K., Brown CJ Speech perception using maps based on neural response telemetry measures. Ear Hear. 2002;23(1 Suppl.):72S-79S.
    • (2002) Ear Hear , vol.23 , pp. 72S-79S
    • Seyle, K.1    Brown, C.J.2
  • 29
    • 10844274615 scopus 로고    scopus 로고
    • Mandarin speech perception in nucleus CI 24 implantees using MAPs based on neural response telemetry. ORL
    • Sun YS, Wu CM, Liu TC Mandarin speech perception in nucleus CI 24 implantees using MAPs based on neural response telemetry. ORL J Otorhinolaryngol Relat Spec. 2004;66:255-261.
    • (2004) J Otorhinolaryngol Relat Spec , vol.66 , pp. 255-261
    • Sun, Y.S.1    Wu, C.M.2    Liu, T.C.3
  • 30
    • 4444342596 scopus 로고    scopus 로고
    • NRT-based versus behavioral-based MAP: a comparison of parameters and speech perception in young children
    • Kaplan-Neeman R., Henkin Y., Yakir Z., et al. NRT-based versus behavioral-based MAP: a comparison of parameters and speech perception in young children. J Basic Clin Physiol Pharmacol. 2004;15:57-69.
    • (2004) J Basic Clin Physiol Pharmacol. , vol.15 , pp. 57-69
    • Kaplan-Neeman, R.1    Henkin, Y.2    Yakir, Z.3
  • 31
    • 0035096819 scopus 로고    scopus 로고
    • Comparison of speech recognition with different speech coding strategies (SPEAK, CIS, and ACE) and their relationship to telemetric measures of compound action potentials in the nucleus CI 24M cochlear implant system
    • Kiefer J., Hohl S., Sturzebecher E., Pfennigdorff T., Gstoettner W. Comparison of speech recognition with different speech coding strategies (SPEAK, CIS, and ACE) and their relationship to telemetric measures of compound action potentials in the nucleus CI 24M cochlear implant system. Audiology. 2001;40:32-42.
    • (2001) Audiology , vol.40 , pp. 32-42
    • Kiefer, J.1    Hohl, S.2    Sturzebecher, E.3    Pfennigdorff, T.4    Gstoettner, W.5
  • 32
    • 4143096003 scopus 로고    scopus 로고
    • Objective measurements of auditory nerve recovery function in nucleus CI 24 implantees in relation to subjective preference of stimulation rate
    • Shpak T., Berlin M., Luntz M. Objective measurements of auditory nerve recovery function in nucleus CI 24 implantees in relation to subjective preference of stimulation rate. Acta Otolaryngol. 2004;124:679-683.
    • (2004) Acta Otolaryngol. , vol.124 , pp. 679-683
    • Shpak, T.1    Berlin, M.2    Luntz, M.3
  • 33
    • 0028211941 scopus 로고
    • Intraoperative measures of electrically evoked auditory nerve compound action potential
    • Gantz BJ, Brown CJ, Abbas PJ Intraoperative measures of electrically evoked auditory nerve compound action potential. Am J Otol. 1994;15:137-144.
    • (1994) Am J Otol. , vol.15 , pp. 137-144
    • Gantz, B.J.1    Brown, C.J.2    Abbas, P.J.3
  • 34
    • 0034861132 scopus 로고    scopus 로고
    • Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of Cochlear Corporation's CI24M device
    • Franck KH, Norton SJ Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of Cochlear Corporation's CI24M device. Ear Hear. 2001;22:289-299.
    • (2001) Ear Hear. , vol.22 , pp. 289-299
    • Franck, K.H.1    Norton, S.J.2
  • 35
    • 3042589331 scopus 로고    scopus 로고
    • Spatial spread of neural excitation: comparison of compound action potential and forward-masking data in cochlear implant recipients
    • Cohen LT, Saunders E., Richardson LM Spatial spread of neural excitation: comparison of compound action potential and forward-masking data in cochlear implant recipients. Int J Audiol. 2004;43:346-355.
    • (2004) Int J Audiol , vol.43 , pp. 346-355
    • Cohen, L.T.1    Saunders, E.2    Richardson, L.M.3
  • 36
    • 21244481771 scopus 로고    scopus 로고
    • Electrode interaction in pediatric cochlear implant subjects
    • Eisen MD, Franck KH Electrode interaction in pediatric cochlear implant subjects. J Assoc Res Otolaryngol. 2005;6:160-170.
    • (2005) J Assoc Res Otolaryngol. , vol.6 , pp. 160-170
    • Eisen, M.D.1    Franck, K.H.2
  • 37
    • 33644646903 scopus 로고    scopus 로고
    • The relation between electrophysiologic channel interaction and electrode pitch ranking in cochlear implant recipients
    • Hughes ML, Abbas PJ The relation between electrophysiologic channel interaction and electrode pitch ranking in cochlear implant recipients. J Acoust Soc Am. 2006;119:1527-1537.
    • (2006) J Acoust Soc Am , vol.119 , pp. 1527-1537
    • Hughes, M.L.1    Abbas, P.J.2
  • 38
    • 0038299943 scopus 로고    scopus 로고
    • Spatial spread of neural excitation in cochlear implant recipients: comparison of improved ECAP method and psychophysical forward masking
    • Cohen LT, Richardson LM, Saunders E., Cowan Rsc. Spatial spread of neural excitation in cochlear implant recipients: comparison of improved ECAP method and psychophysical forward masking. Hear Res. 2003; 179:72-87.
    • (2003) Hear Res , vol.179 , pp. 72-87
    • Cohen, L.T.1    Richardson, L.M.2    Saunders, E.3    Cowan, R.4
  • 39
    • 33746781766 scopus 로고    scopus 로고
    • Multichannel cochlear implants: relation of histopathology to performance
    • Fayad JN, Linthicum FH Multichannel cochlear implants: relation of histopathology to performance. Laryngoscope. 2006;116:1310-1320.
    • (2006) Laryngoscope. , vol.116 , pp. 1310-1320
    • Fayad, J.N.1    Linthicum, F.H.2
  • 40
    • 0023526304 scopus 로고
    • Current distributions produced inside and outside the cochlea from a scala tympani electrode array
    • Ifukube T., White RL Current distributions produced inside and outside the cochlea from a scala tympani electrode array. IEEE Trans Biomed Eng. 1987;34:883-890.
    • (1987) IEEE Trans Biomed Eng , vol.34 , pp. 883-890
    • Ifukube, T.1    White, R.L.2
  • 41
    • 0030220924 scopus 로고    scopus 로고
    • Quadrupolar stimulation for cochlear prostheses: modeling and experimental data
    • Jolly CN, Spelman FA, Clopton BM Quadrupolar stimulation for cochlear prostheses: modeling and experimental data. IEEE Trans Biomed Eng. 1996;43: 857-865.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 857-865
    • Jolly, C.N.1    Spelman, F.A.2    Clopton, B.M.3
  • 42
    • 0031851977 scopus 로고    scopus 로고
    • Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents
    • Kral A., Hartmann R., Mortazavi D., Klinke R. Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents. Hear Res. 1998;121:11-28.
    • (1998) Hear Res , vol.121 , pp. 11-28
    • Kral, A.1    Hartmann, R.2    Mortazavi, D.3    Klinke, R.4
  • 43
    • 0021848255 scopus 로고
    • Current distributions in the cat cochlea: a modelling and electrophysiological study
    • O'Leary SJ, Black RC, Clark GM Current distributions in the cat cochlea: a modelling and electrophysiological study. Hear Res. 1985;18:273-281.
    • (1985) Hear Res. , vol.18 , pp. 273-281
    • O'Leary, S.J.1    Black, R.C.2    Clark, G.M.3
  • 44
    • 0025938048 scopus 로고
    • Intracochlear potential distribution with intracochlear and extra-cochlear electrical stimulation in humans
    • Kasper A., Pelizzone M., Montandon P. Intracochlear potential distribution with intracochlear and extra-cochlear electrical stimulation in humans. Ann Otol Rhinol Laryngol. 1991;100:812-816.
    • (1991) Ann Otol Rhinol Laryngol. , vol.100 , pp. 812-816
    • Kasper, A.1    Pelizzone, M.2    Montandon, P.3
  • 45
    • 84998071225 scopus 로고    scopus 로고
    • Telemetry of longitudinal current spread: does it show spatial selectivity?
    • Paper presented at: 1997 Conference on Implantable Auditory Prostheses; August 12-21, 1997; Pacific Grove, CA
    • Mens Lhm, Van den Broek P. Telemetry of longitudinal current spread: does it show spatial selectivity? Paper presented at: 1997 Conference on Implantable Auditory Prostheses; August 12-21, 1997; Pacific Grove, CA.
    • Lhm, M.1    Van den Broek, P.2
  • 46
    • 0344406894 scopus 로고    scopus 로고
    • The Clarion electrode positioner: approximation to the medial wall and current focussing?
    • Mens Lhm, Boyle PJ, Mulder JJ The Clarion electrode positioner: approximation to the medial wall and current focussing? Audiol Neurotol. 2003;8:166-175.
    • (2003) Audiol Neurotol , vol.8 , pp. 166-175
    • Lhm, M.1    Boyle, P.J.2    Mulder, J.J.3
  • 47
    • 84997983532 scopus 로고    scopus 로고
    • Electrical field imaging methodology
    • Paper presented at: Conference on Implantable Auditory Prostheses; August 19-24, 2001; Asilomar, Pacific Grove, CA
    • Faltys M., Griffith G., Segel P., et al. Electrical field imaging methodology. Paper presented at: Conference on Implantable Auditory Prostheses; August 19-24, 2001; Asilomar, Pacific Grove, CA.
    • Faltys, M.1    Griffith, G.2    Segel, P.3
  • 48
    • 9644260485 scopus 로고    scopus 로고
    • Identification of the impedance model of an implanted cochlear prosthesis from intracochlear potential measurements
    • Vanpoucke FJ, Zarowski AJ, Peeters SA Identification of the impedance model of an implanted cochlear prosthesis from intracochlear potential measurements. IEEE Trans Biomed Eng. 2004;51:2174-2183.
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 2174-2183
    • Vanpoucke, F.J.1    Zarowski, A.J.2    Peeters, S.A.3
  • 49
    • 0032854388 scopus 로고    scopus 로고
    • Modelling surface potentials from intra-cochlear electrical stimulation
    • Mens Lhm, Huiskamp G, Broek Pvd, Oostendorp TF. Modelling surface potentials from intra-cochlear electrical stimulation. Scand Audiol. 1999;28:249-255.
    • (1999) Scand Audiol. , vol.28 , pp. 249-255
    • Lhm, M.1    Huiskamp, G.2    Broek, P.3    Oostendorp, T.F.4
  • 50
    • 0027957146 scopus 로고
    • Cochlear implant generated surface potentials: current spread and side effects
    • Mens Lhm, Oostendorp TF, Van den Broek P. Cochlear implant generated surface potentials: current spread and side effects. Ear Hear. 1994;15:339-345.
    • (1994) Ear Hear. , vol.15 , pp. 339-345
    • Lhm, M.1    Oostendorp, T.F.2    Van den Broek, P.3
  • 51
    • 0027741152 scopus 로고
    • Lumped-parameter model for in vivo cochlear stimulation
    • Suesserman MF, Spelman FA Lumped-parameter model for in vivo cochlear stimulation. IEEE Trans Biomed Eng. 1993;40:237-245.
    • (1993) IEEE Trans Biomed Eng , vol.40 , pp. 237-245
    • Suesserman, M.F.1    Spelman, F.A.2
  • 52
    • 4043087927 scopus 로고    scopus 로고
    • The facial nerve canal: an important cochlear conduction path revealed by Clarion electrical field imaging
    • Vanpoucke F., Zarowski A., Casselman J., Frijns J., Peeters S. The facial nerve canal: an important cochlear conduction path revealed by Clarion electrical field imaging. Otol Neurotol. 2004;25:282-289.
    • (2004) Otol Neurotol , vol.25 , pp. 282-289
    • Vanpoucke, F.1    Zarowski, A.2    Casselman, J.3    Frijns, J.4    Peeters, S.5
  • 54
    • 13144259214 scopus 로고    scopus 로고
    • Telemetry: features and applications
    • In: Cullington HE, ed. London, England: Whurr
    • Mens Lhm. Telemetry: features and applications. In: Cullington HE, ed. Cochlear Implants: Objective Measures. London, England: Whurr; 2003:23-39.
    • (2003) Cochlear Implants: Objective Measures , pp. 23-39
    • Mens, L.1
  • 55
    • 22644434567 scopus 로고    scopus 로고
    • Cochlear implant soft failures consensus development conference statement
    • Balkany TJ, Hodges AV, Buchman CA, et al. Cochlear implant soft failures consensus development conference statement. Otol Neurotol. 2005;26:815-818.
    • (2005) Otol Neurotol , vol.26 , pp. 815-818
    • Balkany, T.J.1    Hodges, A.V.2    Buchman, C.A.3
  • 56
    • 84997985239 scopus 로고    scopus 로고
    • Diagnosing implant failures with the nucleus integrity test system
    • Paper presented at: Fourth International Symposium and Workshops: Objective Measures in Cochlear Implants; June 1-4, 2005; Hannover, Germany
    • Mauch H., Möller C., Nevison B. Diagnosing implant failures with the nucleus integrity test system. Paper presented at: Fourth International Symposium and Workshops: Objective Measures in Cochlear Implants; June 1-4, 2005; Hannover, Germany.
    • Mauch, H.1    Möller, C.2    Nevison, B.3
  • 57
    • 4243859236 scopus 로고    scopus 로고
    • Determining electrode faults using different stimulation modes
    • Paper presented at: XVI World Congress of ORL—Head and Neck Surgery 1997; Sydney, Australia
    • Carter P. Determining electrode faults using different stimulation modes. Paper presented at: XVI World Congress of ORL—Head and Neck Surgery 1997; Sydney, Australia.
    • Carter, P.1
  • 58
    • 0032807219 scopus 로고    scopus 로고
    • Growth factors, auditory neurones and cochlear implants: a review
    • Marzella PL, Clark GM Growth factors, auditory neurones and cochlear implants: a review. Acta Otolaryngol. 1999; 119:407-412.
    • (1999) Acta Otolaryngol , vol.119 , pp. 407-412
    • Marzella, P.L.1    Clark, G.M.2
  • 59
    • 0037459784 scopus 로고    scopus 로고
    • Mechanism of electrical stimulation-induced neuroprotection: effects of verapamil on protection of primary auditory afferents
    • Miller AL, Prieskorn DM, Altschuler RA, Miller JM Mechanism of electrical stimulation-induced neuroprotection: effects of verapamil on protection of primary auditory afferents. Brain Res. 2003;966:218-230.
    • (2003) Brain Res. , vol.966 , pp. 218-230
    • Miller, A.L.1    Prieskorn, D.M.2    Altschuler, R.A.3    Miller, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.