The clarion electrode positioner: Approximation to the medial wall and current focussing?

Author keywords

Channel separation; Cochlear implants; Current spread; Electrical field; Electrode positioner; Modiolus hugging

Indexed keywords

ADOLESCENT; ADULT; AMPLITUDE MODULATION; ARTICLE; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE; ELECTRIC FIELD; ELECTRIC POTENTIAL; ELECTRODE; FEMALE; HUMAN; IMPEDANCE; MALE; PRIORITY JOURNAL; REDUCTION; STIMULATION;

EID: 0344406894     PISSN: 14203030     EISSN: None     Source Type: Journal    
DOI: 10.1159/000069477     Document Type: Article
Times cited : (21)

References (32)
  • 1
    • 0020645008 scopus 로고
    • Current distributions in cochlear stimulation
    • Black RC, Clark GM: Current distributions in cochlear stimulation. Ann NY Acad Sci 1983;405:137-145.
    • (1983) Ann NY Acad Sci , vol.405 , pp. 137-145
    • Black, R.C.1    Clark, G.M.2
  • 2
    • 0034307504 scopus 로고    scopus 로고
    • Field patterns in a 3D tapered spiral model of the electrically stimulated cochlea
    • Briaire JJ, Frijns JH: Field patterns in a 3D tapered spiral model of the electrically stimulated cochlea. Hear Res 2000;148:18-30.
    • (2000) Hear Res , vol.148 , pp. 18-30
    • Briaire, J.J.1    Frijns, J.H.2
  • 4
    • 0034009593 scopus 로고    scopus 로고
    • A silastic positioner for a modiolus-hugging position of intracochlear electrodes: Electrophysiologic effects
    • Cords SM, Reuter G, Issing PR, Sommer A, Kuzma J, Lenarz T: A silastic positioner for a modiolus-hugging position of intracochlear electrodes: Electrophysiologic effects. Am J Otol 2000;21:212-217.
    • (2000) Am J Otol , vol.21 , pp. 212-217
    • Cords, S.M.1    Reuter, G.2    Issing, P.R.3    Sommer, A.4    Kuzma, J.5    Lenarz, T.6
  • 5
    • 0034883918 scopus 로고    scopus 로고
    • Effects of the Clarion Electrode Positioning System on auditory thresholds and comfortable loudness levels in pediatric patients with cochlear implants
    • Donaldson GS, Peters MD, Ellis MR, Friedman BJ, Levine SC, Rimell FL: Effects of the Clarion Electrode Positioning System on auditory thresholds and comfortable loudness levels in pediatric patients with cochlear implants. Arch Otolaryngol Head Neck Surg 2001;127:956-960.
    • (2001) Arch Otolaryngol Head Neck Surg , vol.127 , pp. 956-960
    • Donaldson, G.S.1    Peters, M.D.2    Ellis, M.R.3    Friedman, B.J.4    Levine, S.C.5    Rimell, F.L.6
  • 8
    • 0034054761 scopus 로고    scopus 로고
    • The Clarion electrode positioner: Temporal bone studies
    • Fayad JN, Luxford W, Linthicum FH: The Clarion electrode positioner: Temporal bone studies. Am J Otol 2000;21:226-229.
    • (2000) Am J Otol , vol.21 , pp. 226-229
    • Fayad, J.N.1    Luxford, W.2    Linthicum, F.H.3
  • 10
    • 0035025489 scopus 로고    scopus 로고
    • The importance of human cochlear anatomy for the results of modiolus-hugging multichannel cochlear implants
    • Frijns JH, Briaire JJ, Grote JJ: The importance of human cochlear anatomy for the results of modiolus-hugging multichannel cochlear implants. Otol Neurotol 2001;22:340-349.
    • (2001) Otol Neurotol , vol.22 , pp. 340-349
    • Frijns, J.H.1    Briaire, J.J.2    Grote, J.J.3
  • 11
    • 0028243130 scopus 로고
    • Electrical properties of implant encapsulation tissue
    • Grill WW, Mortimer JT: Electrical properties of implant encapsulation tissue. Ann Biomed Eng 1994;22:23-33.
    • (1994) Ann Biomed Eng , vol.22 , pp. 23-33
    • Grill, W.W.1    Mortimer, J.T.2
  • 13
    • 0023526304 scopus 로고
    • Current distributions produced inside and outside the cochlea from a scala tympani electrode array
    • Ifukube T, White RL: Current distributions produced inside and outside the cochlea from a scala tympani electrode array. IEEE Trans Biomed Eng 1987;34:883-890.
    • (1987) IEEE Trans Biomed Eng , vol.34 , pp. 883-890
    • Ifukube, T.1    White, R.L.2
  • 14
    • 0030220924 scopus 로고    scopus 로고
    • Quadrupolar stimulation for cochlear prostheses: Modeling and experimental data
    • Jolly CN, Spelman FA, Clopton BM: Quadrupolar stimulation for cochlear prostheses: Modeling and experimental data. IEEE Trans Biomed Eng 1996;43:857-865.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 857-865
    • Jolly, C.N.1    Spelman, F.A.2    Clopton, B.M.3
  • 16
    • 0025938048 scopus 로고
    • Intracochlear potential distribution with intracochlear and extracochlear electrical stimulation in humans
    • Kasper A, Pelizzone M, Montandon P: Intracochlear potential distribution with intracochlear and extracochlear electrical stimulation in humans. Ann Otol Rhinol Laryngol 1991;100:812-816.
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 812-816
    • Kasper, A.1    Pelizzone, M.2    Montandon, P.3
  • 17
    • 0031851977 scopus 로고    scopus 로고
    • Spatial resolution of cochlear implants: The electrical field and excitation of auditory afferents
    • Kral A, Hartmann R, Mortazavi D, Klinke R: Spatial resolution of cochlear implants: The electrical field and excitation of auditory afferents. Hear Res 1998;121:11-28.
    • (1998) Hear Res , vol.121 , pp. 11-28
    • Kral, A.1    Hartmann, R.2    Mortazavi, D.3    Klinke, R.4
  • 20
    • 0027236682 scopus 로고
    • Radiologic evaluation of multichannel intracochlear implant insertion depth
    • published erratum in Am J Otol 1993 Nov;14:627
    • Marsh M A, Xu J, Blamey PJ, Whitford LA, Xu SA, Silverman JM, Clark GM: Radiologic evaluation of multichannel intracochlear implant insertion depth. Am J Otol 1993;14:386-391. [published erratum in Am J Otol 1993 Nov;14: 627].
    • (1993) Am J Otol , vol.14 , pp. 386-391
    • Marsh, M.A.1    Xu, J.2    Blamey, P.J.3    Whitford, L.A.4    Xu, S.A.5    Silverman, J.M.6    Clark, G.M.7
  • 21
    • 0344521378 scopus 로고
    • Averaged electrode voltages and pitch scaling showing current spread in the case of electrode failures and otosclerosis
    • Melbourne
    • Mens LHM, Brokx JPL, Van den Broek P: Averaged electrode voltages and pitch scaling showing current spread in the case of electrode failures and otosclerosis. Presented at The International Cochlear Implant, Speech and Hearing Symposium. Melbourne, 1994a, p 194.
    • (1994) International Cochlear Implant, Speech and Hearing Symposium , pp. 194
    • Mens, L.H.M.1    Brokx, J.P.L.2    Van Den Broek, P.3
  • 22
    • 0027957146 scopus 로고
    • Cochlear implant generated surface potentials: Current spread and side effects
    • Mens LHM, Oostendorp TF, Van den Broek P: Cochlear implant generated surface potentials: Current spread and side effects. Ear Hear 1994b;15:339-345.
    • (1994) Ear Hear , vol.15 , pp. 339-345
    • Mens, L.H.M.1    Oostendorp, T.F.2    Van Den Broek, P.3
  • 24
    • 0035014013 scopus 로고    scopus 로고
    • Cochlear structures after implantation of a perimodiolar electrode array
    • Richter B, Jaekel K, Aschendorff A, Marangos N, Laszig R: Cochlear structures after implantation of a perimodiolar electrode array. Laryngoscope 2001;111:837-843.
    • (2001) Laryngoscope , vol.111 , pp. 837-843
    • Richter, B.1    Jaekel, K.2    Aschendorff, A.3    Marangos, N.4    Laszig, R.5
  • 25
    • 0034093831 scopus 로고    scopus 로고
    • Electrode to modiolus proximity: A fluoroscopic and histologic analysis
    • Roland JT, Fishman AJ, Alexiades G, Cohen NL: Electrode to modiolus proximity: A fluoroscopic and histologic analysis. Am J Otol 2000;21:218-225.
    • (2000) Am J Otol , vol.21 , pp. 218-225
    • Roland, J.T.1    Fishman, A.J.2    Alexiades, G.3    Cohen, N.L.4
  • 27
    • 0027503532 scopus 로고
    • Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
    • Shepherd RK, Hatsushika S, Clark GM: Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation. Hear Res 1993;66:108-120.
    • (1993) Hear Res , vol.66 , pp. 108-120
    • Shepherd, R.K.1    Hatsushika, S.2    Clark, G.M.3
  • 28
    • 0020186587 scopus 로고
    • Tissue impedance and current flow in the implanted ear. Implications for the cochlear prosthesis
    • Spelman FA, Clopton BM, Pfingst BE: Tissue impedance and current flow in the implanted ear. Implications for the cochlear prosthesis. Ann Otol Rhinol Laryngol Suppl 1982;98:3-8.
    • (1982) Ann Otol Rhinol Laryngol Suppl , vol.98 , pp. 3-8
    • Spelman, F.A.1    Clopton, B.M.2    Pfingst, B.E.3
  • 30
    • 0034533891 scopus 로고    scopus 로고
    • Novel intracochlear electrode positioner: Effects on electrode position
    • Yang NW, Hodges AV, Balkany TJ: Novel intracochlear electrode positioner: Effects on electrode position. Ann Otol Rhinol Laryngol Suppl 2000:185:18-20.
    • (2000) Ann Otol Rhinol Laryngol Suppl , vol.185 , pp. 18-20
    • Yang, N.W.1    Hodges, A.V.2    Balkany, T.J.3
  • 31
    • 0035078004 scopus 로고    scopus 로고
    • Comparison of pediatric Clarion recipients with and without the electrode positioner
    • Young NM, Grohne KM: Comparison of pediatric Clarion recipients with and without the electrode positioner. Otol Neurotol 2001;22:195-199.
    • (2001) Otol Neurotol , vol.22 , pp. 195-199
    • Young, N.M.1    Grohne, K.M.2
  • 32
    • 0029267320 scopus 로고
    • Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies
    • Zierhofer CM, Hochmair-Desoyer IJ, Hochmair ES: Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies. IEEE Trans Rehab Eng 1995;3:112-116.
    • (1995) IEEE Trans Rehab Eng , vol.3 , pp. 112-116
    • Zierhofer, C.M.1    Hochmair-Desoyer, I.J.2    Hochmair, E.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.