-
1
-
-
44249116685
-
Digital dentistry: An overview of recent developments for CAD/CAM generated restorations
-
18469768
-
Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J. 2008; 204: 505-511. doi: 10.1038/sj.bdj.2008.350 PMID: 18469768
-
(2008)
Br Dent J.
, vol.204
, pp. 505-511
-
-
Beuer, F.1
Schweiger, J.2
Edelhoff, D.3
-
2
-
-
84922505345
-
Ceramic dental biomaterials and CAD/CAM technology: State of the art
-
25172234
-
Li RW, Chow TW, Matinlinna JP. Ceramic dental biomaterials and CAD/CAM technology: state of the art. J Prosthodont Res. 2014; 58: 208-216. doi: 10.1016/j.jpor.2014.07.003 PMID: 25172234
-
(2014)
J Prosthodont Res.
, vol.58
, pp. 208-216
-
-
Li, R.W.1
Chow, T.W.2
Matinlinna, J.P.3
-
3
-
-
84906810234
-
Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication
-
24882595
-
Kattadiyil MT, Mursic Z, AlRumaih H, Goodacre CJ. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent. 2014; 112: 444-448. doi: 10.1016/j. prosdent.2014.03.022 PMID: 24882595
-
(2014)
J Prosthet Dent.
, vol.112
, pp. 444-448
-
-
Kattadiyil, M.T.1
Mursic, Z.2
AlRumaih, H.3
Goodacre, C.J.4
-
4
-
-
84991248477
-
Examination of the fitting precision of all-ceramic bridges manufactured by intraoral digital impression
-
Takuma Y, Yasuda H, Sato T, Hisanaga R. Examination of the fitting precision of all-ceramic bridges manufactured by intraoral digital impression. J Esthet Dent. 2013; 26: 1-7.
-
(2013)
J Esthet Dent.
, vol.26
, pp. 1-7
-
-
Takuma, Y.1
Yasuda, H.2
Sato, T.3
Hisanaga, R.4
-
5
-
-
84875994171
-
Using digitally coded healing abutments and an intraoral scanner to fabricate implant-supported, cement-retained restorations
-
23566600
-
Nayyar N, Yilmaz B, McGlumphy E. Using digitally coded healing abutments and an intraoral scanner to fabricate implant-supported, cement-retained restorations. J Prosthet Dent. 2013; 109: 210-215. doi: 10.1016/S0022-3913(13)00073-5 PMID: 23566600
-
(2013)
J Prosthet Dent.
, vol.109
, pp. 210-215
-
-
Nayyar, N.1
Yilmaz, B.2
McGlumphy, E.3
-
6
-
-
84871692499
-
Digital vs. Conventional implant impressions: Efficiency outcomes
-
22353208
-
Lee SJ, Gallucci GO. Digital vs. conventional implant impressions: efficiency outcomes. Clin Oral Implants Res. 2013; 24: 111-115. doi: 10.1111/j.1600-0501.2012.02430.x PMID: 22353208
-
(2013)
Clin Oral Implants Res.
, vol.24
, pp. 111-115
-
-
Lee, S.J.1
Gallucci, G.O.2
-
7
-
-
33749241323
-
The evolution of the CEREC system
-
16950932
-
Mormann WH. The evolution of the CEREC system. J Am Dent Assoc. 2006; 137 Suppl: 7S-13S. PMID: 16950932
-
(2006)
J Am Dent Assoc.
, vol.137
, pp. 7S-13S
-
-
Mormann, W.H.1
-
8
-
-
0242405556
-
Longevity of 2328 chairside Cerec inlays and onlays
-
14601187
-
Posselt A, Kerschbaum T. Longevity of 2328 chairside Cerec inlays and onlays. Int J Comput Dent. 2003; 6: 231-248. PMID: 14601187
-
(2003)
Int J Comput Dent.
, vol.6
, pp. 231-248
-
-
Posselt, A.1
Kerschbaum, T.2
-
9
-
-
1842841840
-
A 10-year prospective evaluation of CAD/CAM-manufactured (Cerec) ceramic inlays cemented with a chemically cured or dual-cured resin composite
-
15119879
-
Sjogren G, Molin M, van Dijken JW. A 10-year prospective evaluation of CAD/CAM-manufactured (Cerec) ceramic inlays cemented with a chemically cured or dual-cured resin composite. Int J Prosthodont. 2004; 17: 241-246. PMID: 15119879
-
(2004)
Int J Prosthodont.
, vol.17
, pp. 241-246
-
-
Sjogren, G.1
Molin, M.2
Van Dijken, J.W.3
-
10
-
-
53249090606
-
Long-term survival of Cerec restorations: A 10-year study
-
18833853
-
Zimmer S, Gohlich O, Ruttermann S, Lang H, Raab WH, Barthel CR. Long-term survival of Cerec restorations: a 10-year study. Oper Dent. 2008; 33: 484-487. doi: 10.2341/07-142 PMID: 18833853
-
(2008)
Oper Dent.
, vol.33
, pp. 484-487
-
-
Zimmer, S.1
Gohlich, O.2
Ruttermann, S.3
Lang, H.4
Raab, W.H.5
Barthel, C.R.6
-
11
-
-
84886414697
-
Current status of zirconia restoration
-
24140561
-
Miyazaki T, Nakamura T, Matsumura H, Ban S, Kobayashi T. Current status of zirconia restoration. J Prosthodont Res. 2013; 57: 236-261. doi: 10.1016/j.jpor.2013.09.001 PMID: 24140561
-
(2013)
J Prosthodont Res.
, vol.57
, pp. 236-261
-
-
Miyazaki, T.1
Nakamura, T.2
Matsumura, H.3
Ban, S.4
Kobayashi, T.5
-
12
-
-
52449134942
-
A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions
-
18578100 426-428, 430-431
-
Henkel GL. A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions. Compend Contin Educ Dent. 2007; 28: 422-424, 426-428, 430-431. PMID: 18578100
-
(2007)
Compend Contin Educ Dent.
, vol.28
, pp. 422-424
-
-
Henkel, G.L.1
-
13
-
-
84912128995
-
A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes
-
24993373
-
Bosch G, Ender A, Mehl A. A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes. J Prosthet Dent. 2014; 112: 1425-1431. doi: 10.1016/j.prosdent.2014.05.012 PMID: 24993373
-
(2014)
J Prosthet Dent.
, vol.112
, pp. 1425-1431
-
-
Bosch, G.1
Ender, A.2
Mehl, A.3
-
14
-
-
84863938328
-
A new concept for the integration of dynamic occlusion in the digital construction process
-
22891415
-
Mehl A. A new concept for the integration of dynamic occlusion in the digital construction process. Int J Comput Dent. 2012; 15: 109-123. PMID: 22891415
-
(2012)
Int J Comput Dent.
, vol.15
, pp. 109-123
-
-
Mehl, A.1
-
15
-
-
84875132149
-
Accuracy and reliability of a novel method for fusion of digital dental casts and Cone Beam Computed Tomography scans
-
23527111
-
Rangel FA, Maal TJ, Bronkhorst EM, Breuning KH, Schols JG, Bergé SJ, et al. Accuracy and reliability of a novel method for fusion of digital dental casts and Cone Beam Computed Tomography scans. PLoS One. 2013; 8: e59130. doi: 10.1371/journal.pone.0059130 PMID: 23527111
-
(2013)
PLoS One.
, vol.8
-
-
Rangel, F.A.1
Maal, T.J.2
Bronkhorst, E.M.3
Breuning, K.H.4
Schols, J.G.5
Bergé, S.J.6
-
16
-
-
80054029357
-
Clinical evaluation of a dental color analysis system: The Crystaleye Spectrophotometer1
-
21296639
-
Odaira C, Itoh S, Ishibashi K. Clinical evaluation of a dental color analysis system: the Crystaleye Spectrophotometer1. J Prosthodont Res. 2011; 55: 199-205. doi: 10.1016/j.jpor.2010.12.005 PMID: 21296639
-
(2011)
J Prosthodont Res.
, vol.55
, pp. 199-205
-
-
Odaira, C.1
Itoh, S.2
Ishibashi, K.3
-
17
-
-
84894804838
-
Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study
-
24210732
-
Andriessen FS, Rijkens DR, van der Meer WJ, Wismeijer DW. Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: a pilot study. J Prosthet Dent. 2014; 111: 186-194. doi: 10.1016/j.prosdent.2013.07.010 PMID: 24210732
-
(2014)
J Prosthet Dent.
, vol.111
, pp. 186-194
-
-
Andriessen, F.S.1
Rijkens, D.R.2
Van Der Meer, W.J.3
Wismeijer, D.W.4
-
18
-
-
79952113212
-
Digital dentistry: Innovation for restorative treatment
-
21049823
-
Fasbinder DJ. Digital dentistry: innovation for restorative treatment. Compend Contin Educ Dent. 2010; 31 Spec No 4: 2-11. PMID: 21049823
-
(2010)
Compend Contin Educ Dent.
, vol.31
, pp. 2-11
-
-
Fasbinder, D.J.1
-
19
-
-
0022053780
-
Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models
-
3889281
-
Johnson GH, Craig RG. Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models. J Prosthet Dent. 1985; 53: 484-490. doi: 10.1016/0022-3913(85) 90630-4 PMID: 3889281
-
(1985)
J Prosthet Dent.
, vol.53
, pp. 484-490
-
-
Johnson, G.H.1
Craig, R.G.2
-
20
-
-
0026857669
-
Determining the accuracy of gypsum casts made from type IV dental stone
-
1500967
-
Millstein PL. Determining the accuracy of gypsum casts made from type IV dental stone. J Oral Rehabil. 1992; 19: 239-243. doi: 10.1111/j.1365-2842.1992.tb01098.x PMID: 1500967
-
(1992)
J Oral Rehabil.
, vol.19
, pp. 239-243
-
-
Millstein, P.L.1
-
21
-
-
79954438032
-
Full arch scans: Conventional versus digital impressions-an in-vitro study
-
21657122
-
Ender A, Mehl A. Full arch scans: conventional versus digital impressions-an in-vitro study. Int J Comput Dent. 2011; 14: 11-21. PMID: 21657122
-
(2011)
Int J Comput Dent.
, vol.14
, pp. 11-21
-
-
Ender, A.1
Mehl, A.2
-
22
-
-
84857795655
-
Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD/CAM system
-
22050205
-
Souza RO, Ozcan M, Pavanelli CA, Buso L, Lombardo GH, Michida SM, et al. Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD/CAM system. J Prosthodont. 2012; 21: 94-100. doi: 10.1111/j.1532-849X.2011.00793.x PMID: 22050205
-
(2012)
J Prosthodont.
, vol.21
, pp. 94-100
-
-
Souza, R.O.1
Ozcan, M.2
Pavanelli, C.A.3
Buso, L.4
Lombardo, G.H.5
Michida, S.M.6
-
23
-
-
84865511249
-
Dental models made with an intraoral scanner: A validation study
-
22920696
-
Cuperus AM, Harms MC, Rangel FA, Bronkhorst EM, Schols JG, Breuning KH. Dental models made with an intraoral scanner: a validation study. Am J Orthod Dentofacial Orthop. 2012; 142: 308-313. doi: 10.1016/j.ajodo.2012.03.031 PMID: 22920696
-
(2012)
Am J Orthod Dentofacial Orthop.
, vol.142
, pp. 308-313
-
-
Cuperus, A.M.1
Harms, M.C.2
Rangel, F.A.3
Bronkhorst, E.M.4
Schols, J.G.5
Breuning, K.H.6
-
24
-
-
84902210488
-
Using stereophotogrammetric technology for obtaining intraoral digital impressions of implants
-
24686966
-
Pradies G, Ferreiroa A, Ozcan M, Gimenez B, Martinez-Rus F. Using stereophotogrammetric technology for obtaining intraoral digital impressions of implants. J Am Dent Assoc. 2014; 145: 338-344. doi: 10.14219/jada.2013.45 PMID: 24686966
-
(2014)
J Am Dent Assoc.
, vol.145
, pp. 338-344
-
-
Pradies, G.1
Ferreiroa, A.2
Ozcan, M.3
Gimenez, B.4
Martinez-Rus, F.5
-
25
-
-
77957280346
-
Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
-
20381576
-
Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent. 2010; 38: 553-559. doi: 10.1016/j.jdent.2010.03.015 PMID: 20381576
-
(2010)
J Dent.
, vol.38
, pp. 553-559
-
-
Syrek, A.1
Reich, G.2
Ranftl, D.3
Klein, C.4
Cerny, B.5
Brodesser, J.6
-
26
-
-
33644881396
-
A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration
-
16543025
-
Grossmann Y, Pasciuta M, Finger IM. A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration. J Prosthet Dent. 2006; 95: 258-261. doi: 10.1016/j.prosdent.2005.12.013 PMID: 16543025
-
(2006)
J Prosthet Dent.
, vol.95
, pp. 258-261
-
-
Grossmann, Y.1
Pasciuta, M.2
Finger, I.M.3
-
27
-
-
52249092953
-
Computer-generated abutments using a coded healing abutment: A two year preliminary report
-
17929687
-
Vafiadis DC. Computer-generated abutments using a coded healing abutment: a two year preliminary report. Pract Proced Aesthet Dent. 2007; 19: 443-448. PMID: 17929687
-
(2007)
Pract Proced Aesthet Dent.
, vol.19
, pp. 443-448
-
-
Vafiadis, D.C.1
-
28
-
-
84865176071
-
Application of intra-oral dental scanners in the digital workflow of implantology
-
22937030
-
van der Meer WJ, Andriessen FS, Wismeijer D, Ren Y. Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One. 2012; 7: e43312. doi: 10.1371/journal.pone.0043312 PMID: 22937030
-
(2012)
PLoS One.
, vol.7
-
-
Van Der Meer, W.J.1
Andriessen, F.S.2
Wismeijer, D.3
Ren, Y.4
-
29
-
-
84873578014
-
Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision
-
23395338
-
Ender A, Mehl A. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. J Prosthet Dent. 2013; 109: 121-128. doi: 10.1016/S0022-3913(13)60028-1 PMID: 23395338
-
(2013)
J Prosthet Dent.
, vol.109
, pp. 121-128
-
-
Ender, A.1
Mehl, A.2
-
30
-
-
84902765111
-
Accuracy of full-arch scans using intraoral scanners
-
24240949
-
Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig. 2014; 18: 1687-1694. doi: 10.1007/s00784-013-1132-y PMID: 24240949
-
(2014)
Clin Oral Investig.
, vol.18
, pp. 1687-1694
-
-
Patzelt, S.B.1
Emmanouilidi, A.2
Stampf, S.3
Strub, J.R.4
Att, W.5
-
31
-
-
84912077800
-
Scanning accuracy and precision in 4 intraoral scanners: An in vitro comparison based on 3-dimensional analysis
-
25134995
-
Nedelcu RG, Persson AS. Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis. J Prosthet Dent. 2014; 112: 1461-1471. doi: 10.1016/j. prosdent.2014.05.027 PMID: 25134995
-
(2014)
J Prosthet Dent.
, vol.112
, pp. 1461-1471
-
-
Nedelcu, R.G.1
Persson, A.S.2
-
32
-
-
84867400213
-
Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling
-
22027653
-
Scotti R, Cardelli P, Baldissara P, Monaco C. Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling. J Dent. 2011:doi: 10.1016/j.jdent.2011.10.005 PMID: 22027653
-
(2011)
J Dent.
-
-
Scotti, R.1
Cardelli, P.2
Baldissara, P.3
Monaco, C.4
-
33
-
-
84897902654
-
Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions
-
24723954
-
Svanborg P, Skjerven H, Carlsson P, Eliasson A, Karlsson S,Örtorp A. Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions. Int J Dent. 2014; 2014: 534382. doi: 10.1155/2014/534382 PMID: 24723954
-
(2014)
Int J Dent.
, vol.2014
, pp. 534382
-
-
Svanborg, P.1
Skjerven, H.2
Carlsson, P.3
Eliasson, A.4
Karlsson, S.5
Örtorp, A.6
-
34
-
-
52249091557
-
The accuracy of implant impressions: A systematic review
-
18922257
-
Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: A systematic review. J Prosthet Dent. 2008; 100: 285-291. doi: 10.1016/S0022-3913(08)60208-5 PMID: 18922257
-
(2008)
J Prosthet Dent.
, vol.100
, pp. 285-291
-
-
Lee, H.1
So, J.S.2
Hochstedler, J.L.3
Ercoli, C.4
-
35
-
-
11444261183
-
Evaluation of transfer impressions for osseointegrated implants at various angulations
-
15591998
-
Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent. 2004; 13: 358-366. PMID: 15591998
-
(2004)
Implant Dent.
, vol.13
, pp. 358-366
-
-
Assuncao, W.G.1
Filho, H.G.2
Zaniquelli, O.3
-
36
-
-
0026311384
-
Comparison of impression techniques for a five-implant mandibular model
-
1820314
-
Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants. 1991; 6: 448-455. PMID: 1820314
-
(1991)
Int J Oral Maxillofac Implants.
, vol.6
, pp. 448-455
-
-
Carr, A.B.1
-
37
-
-
44949111488
-
The mucosal barrier at implant abutments of different materials
-
18492075
-
Welander M, Abrahamsson I, Berglundh T. The mucosal barrier at implant abutments of different materials. Clin Oral Implants Res. 2008; 19: 635-641. doi: 10.1111/j.1600-0501.2008.01543.x PMID: 18492075
-
(2008)
Clin Oral Implants Res.
, vol.19
, pp. 635-641
-
-
Welander, M.1
Abrahamsson, I.2
Berglundh, T.3
|