메뉴 건너뛰기




Volumn 21, Issue 2, 2012, Pages 94-100

Marginal and Internal Discrepancies Related to Margin Design of Ceramic Crowns Fabricated by a CAD/CAM System

Author keywords

CAD CAM system; Internal discrepancy; Marginal discrepancy

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; COMPUTER AIDED DESIGN; DENTAL IMPRESSION; DENTAL PROCEDURE; DENTAL SURGERY; ENDODONTICS; HISTOLOGY; HUMAN; NONPARAMETRIC TEST; PROSTHESIS; TOOTH CROWN; TOOTH PROSTHESIS;

EID: 84857795655     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2011.00793.x     Document Type: Article
Times cited : (92)

References (48)
  • 1
    • 0030207973 scopus 로고    scopus 로고
    • The clinical performance of CAD/CAM-generated ceramics inlays. A four year study
    • Heymann HD, Bayne SC, Sturdevant JR, et al: The clinical performance of CAD/CAM-generated ceramics inlays. A four year study. J Am Dent Assoc 1996;127:1171-1181.
    • (1996) J Am Dent Assoc , vol.127 , pp. 1171-1181
    • Heymann, H.D.1    Bayne, S.C.2    Sturdevant, J.R.3
  • 2
    • 2342652157 scopus 로고    scopus 로고
    • Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years
    • Bindl A, Mörmann WH: Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years. Eur J Oral Sci 2004;112:197-204.
    • (2004) Eur J Oral Sci , vol.112 , pp. 197-204
    • Bindl, A.1    Mörmann, W.H.2
  • 3
    • 33645472189 scopus 로고    scopus 로고
    • Multicolored ceramic blocks as an esthetic solution for anterior restorations
    • Kurbad A, Reichel K: Multicolored ceramic blocks as an esthetic solution for anterior restorations. Int J Comput Dent 2006;9:69-82.
    • (2006) Int J Comput Dent , vol.9 , pp. 69-82
    • Kurbad, A.1    Reichel, K.2
  • 4
    • 33749241323 scopus 로고    scopus 로고
    • The evolution of the CEREC system
    • Mörmann WH: The evolution of the CEREC system. J Am Dent Assoc 2006;137:7-13.
    • (2006) J Am Dent Assoc , vol.137 , pp. 7-13
    • Mörmann, W.H.1
  • 6
    • 0025028550 scopus 로고
    • Marginal fit of porcelain-fused-to-metal ad two types of ceramic crown
    • Hung SH, Hung KS, Eidk JD, et al: Marginal fit of porcelain-fused-to-metal ad two types of ceramic crown. J Prosthet Dent 1990;63:26-31.
    • (1990) J Prosthet Dent , vol.63 , pp. 26-31
    • Hung, S.H.1    Hung, K.S.2    Eidk, J.D.3
  • 7
    • 0031116657 scopus 로고    scopus 로고
    • Grit basting and marginal accuracy of two ceramic veneer systems- A pilot study
    • Lim CC, Ironside JG: Grit basting and marginal accuracy of two ceramic veneer systems- A pilot study. J Prosthet Dent 1997;77:359-364.
    • (1997) J Prosthet Dent , vol.77 , pp. 359-364
    • Lim, C.C.1    Ironside, J.G.2
  • 8
    • 25844452849 scopus 로고    scopus 로고
    • Clinical marginal and internal gaps of In-Ceram crowns fabricated using the GN-I system
    • Kokubo Y, Nagayama Y, Tsumita M, et al: Clinical marginal and internal gaps of In-Ceram crowns fabricated using the GN-I system. J Oral Rehabil 2005;32:753-758.
    • (2005) J Oral Rehabil , vol.32 , pp. 753-758
    • Kokubo, Y.1    Nagayama, Y.2    Tsumita, M.3
  • 9
    • 0022868060 scopus 로고
    • Plaque retention on the teeth restored with full-ceramic crowns: a comparative study
    • Chan C, Weber H: Plaque retention on the teeth restored with full-ceramic crowns: a comparative study. J Prosthet Dent 1986;56:666-671.
    • (1986) J Prosthet Dent , vol.56 , pp. 666-671
    • Chan, C.1    Weber, H.2
  • 10
    • 0034328155 scopus 로고    scopus 로고
    • Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures
    • Knoernschild KL, Campbell SD: Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent 2000;84:492-498.
    • (2000) J Prosthet Dent , vol.84 , pp. 492-498
    • Knoernschild, K.L.1    Campbell, S.D.2
  • 11
    • 0014399275 scopus 로고
    • Reactions of marginal periodontal tissues to restorative procedures
    • Löe H: Reactions of marginal periodontal tissues to restorative procedures. Int Dent J 1968;18:759-778.
    • (1968) Int Dent J , vol.18 , pp. 759-778
    • Löe, H.1
  • 12
    • 0017277626 scopus 로고
    • In vitro attachment of Streptococcus sanguis to dental crown and bridge cements
    • Ørstavik D, Ørstavik J: In vitro attachment of Streptococcus sanguis to dental crown and bridge cements. J Oral Rehabil 1976;3:139-144.
    • (1976) J Oral Rehabil , vol.3 , pp. 139-144
    • Ørstavik, D.1    Ørstavik, J.2
  • 13
    • 0018977766 scopus 로고
    • Distortion related to margin design in porcelain-fused-to-metal restorations
    • Faucher RR, Nicholls JI: Distortion related to margin design in porcelain-fused-to-metal restorations. J Prosthet Dent 1980;43:149-155.
    • (1980) J Prosthet Dent , vol.43 , pp. 149-155
    • Faucher, R.R.1    Nicholls, J.I.2
  • 14
    • 0026127426 scopus 로고
    • Effect of in vivo crown margin discrepancies on periodontal health
    • Felton DA, Kanoy BE, Bayne SC, et al: Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991;65:357-364.
    • (1991) J Prosthet Dent , vol.65 , pp. 357-364
    • Felton, D.A.1    Kanoy, B.E.2    Bayne, S.C.3
  • 15
    • 0024294970 scopus 로고
    • Factors affecting the fit of porcelain jacket crowns
    • Alkumru H, Hullah WR, Marquis PM, et al: Factors affecting the fit of porcelain jacket crowns. Br Dental J 1988;164:39-43.
    • (1988) Br Dental J , vol.164 , pp. 39-43
    • Alkumru, H.1    Hullah, W.R.2    Marquis, P.M.3
  • 16
    • 0029242639 scopus 로고
    • The effect of cement thickness on the fracture strength of all- ceramic crowns
    • Tuntiprawon M, Wilson PR: The effect of cement thickness on the fracture strength of all- ceramic crowns. Aust Dent J 1995;40:17-21.
    • (1995) Aust Dent J , vol.40 , pp. 17-21
    • Tuntiprawon, M.1    Wilson, P.R.2
  • 17
    • 0024740530 scopus 로고
    • Considerations in measurement of marginal fit
    • Holmes JR, Bayne SC, Holland GA, et al: Considerations in measurement of marginal fit. J Prosthet Dent 1989;62:405-408.
    • (1989) J Prosthet Dent , vol.62 , pp. 405-408
    • Holmes, J.R.1    Bayne, S.C.2    Holland, G.A.3
  • 18
    • 0024637823 scopus 로고
    • Nondestructive, three-dimensional internal fit mapping of fixed prostheses
    • Kelly JR, Davis SH, Campbell SD: Nondestructive, three-dimensional internal fit mapping of fixed prostheses. J Prosthet Dent 1989;61:368-373.
    • (1989) J Prosthet Dent , vol.61 , pp. 368-373
    • Kelly, J.R.1    Davis, S.H.2    Campbell, S.D.3
  • 20
    • 0035409693 scopus 로고    scopus 로고
    • Marginal fit of alumina and zirconia-based fixed partial dentures produced by a CAD/CAM system
    • Tinschert J, Natt G, Mautsch W, et al: Marginal fit of alumina and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2001;26:367-374.
    • (2001) Oper Dent , vol.26 , pp. 367-374
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3
  • 21
    • 0019325537 scopus 로고
    • The effect of firing shrinkage on the marginal fit of porcelain jacket crowns
    • Lui JL: The effect of firing shrinkage on the marginal fit of porcelain jacket crowns. Br Dent J 1980;15:43-45.
    • (1980) Br Dent J , vol.15 , pp. 43-45
    • Lui, J.L.1
  • 22
    • 0029339631 scopus 로고
    • Marginal accuracy and fracture strength of conventional and copy- milled all-ceramic crowns
    • Rinke S, Hüls A, Jahn L: Marginal accuracy and fracture strength of conventional and copy- milled all-ceramic crowns. Int J Prosthodont 1995;8:303-310.
    • (1995) Int J Prosthodont , vol.8 , pp. 303-310
    • Rinke, S.1    Hüls, A.2    Jahn, L.3
  • 23
    • 0033628733 scopus 로고    scopus 로고
    • Determination of the minimum number of marginal gap measurements required for practical in vitro testing
    • Groten M, Axmann D, Pröbster L, et al: Determination of the minimum number of marginal gap measurements required for practical in vitro testing. J Prosthet Dent 2000;83:40-49.
    • (2000) J Prosthet Dent , vol.83 , pp. 40-49
    • Groten, M.1    Axmann, D.2    Pröbster, L.3
  • 24
    • 0031302220 scopus 로고    scopus 로고
    • Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopy analysis in vitro
    • Groten M, Girthofer S, Pröbster L: Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopy analysis in vitro. J Oral Rehabil 1997;24:871-881.
    • (1997) J Oral Rehabil , vol.24 , pp. 871-881
    • Groten, M.1    Girthofer, S.2    Pröbster, L.3
  • 25
    • 4444369817 scopus 로고    scopus 로고
    • Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines and luting agents: An in vitro evaluation
    • Quintas AF, Oliveira F, Bottino MA: Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines and luting agents: An in vitro evaluation. J Prosthet Dent 2004;92:250-257.
    • (2004) J Prosthet Dent , vol.92 , pp. 250-257
    • Quintas, A.F.1    Oliveira, F.2    Bottino, M.A.3
  • 26
    • 69549084939 scopus 로고    scopus 로고
    • Influence of CAM vs. CAD/CAM scanning methods and finish line of tooth preparation in the vertical misfit of zirconia bridge structures
    • Oyagüe R Castillo de, Sánchez-Jorge MI, et al: Influence of CAM vs. CAD/CAM scanning methods and finish line of tooth preparation in the vertical misfit of zirconia bridge structures. Am J Dent 2009;22:79-83.
    • (2009) Am J Dent , vol.22 , pp. 79-83
    • Oyagüe, R.C.1    Sánchez-Jorge, M.I.2
  • 27
    • 77957293233 scopus 로고    scopus 로고
    • The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns
    • Tao J, Han D: The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns. Quintessence Int 2009;40:745-752.
    • (2009) Quintessence Int , vol.40 , pp. 745-752
    • Tao, J.1    Han, D.2
  • 28
    • 67651011653 scopus 로고    scopus 로고
    • Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    • Beuer F, Aggstaller H, Richter J, et al: Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 2009;40:243-250.
    • (2009) Quintessence Int , vol.40 , pp. 243-250
    • Beuer, F.1    Aggstaller, H.2    Richter, J.3
  • 29
    • 0033158951 scopus 로고    scopus 로고
    • Evaluation of the marginal accuracy of different all-ceramic crown system after simulation in the artificial mouth
    • Beschnidt SM, Strub JR: Evaluation of the marginal accuracy of different all-ceramic crown system after simulation in the artificial mouth. J Oral Rehabil 1999;26:582-593.
    • (1999) J Oral Rehabil , vol.26 , pp. 582-593
    • Beschnidt, S.M.1    Strub, J.R.2
  • 30
    • 0031230677 scopus 로고    scopus 로고
    • In vitro evaluation of glass-ceramic restorative material
    • Pröbster L, Geis-Gerstorfer, Kirchner E, et al: In vitro evaluation of glass-ceramic restorative material. J Oral Rehabil 1997;24:636-645.
    • (1997) J Oral Rehabil , vol.24 , pp. 636-645
    • Pröbster, L.1    Geis-Gerstorfer2    Kirchner, E.3
  • 31
    • 0038488606 scopus 로고    scopus 로고
    • Marginal discrepancies and leakage of all-ceramic crowns: influence of luting agents and aging conditions
    • Gu X, Kern M: Marginal discrepancies and leakage of all-ceramic crowns: influence of luting agents and aging conditions. Int J Prosthodont 2003;16:109-116.
    • (2003) Int J Prosthodont , vol.16 , pp. 109-116
    • Gu, X.1    Kern, M.2
  • 32
    • 0028711133 scopus 로고
    • In vitro marginal adaptation porcelain ceramic crowns
    • Pera P, Gilodi S, Bassi F, et al: In vitro marginal adaptation porcelain ceramic crowns. J Prosthet Dent 1994;72:585-590.
    • (1994) J Prosthet Dent , vol.72 , pp. 585-590
    • Pera, P.1    Gilodi, S.2    Bassi, F.3
  • 33
    • 0032196114 scopus 로고    scopus 로고
    • The effect of tooth preparation form on the fit of Procera copings
    • Lin MT, Sy-Muñoz J, Muñoz CA: The effect of tooth preparation form on the fit of Procera copings. Int J Prosthodont 1998;11:580-590.
    • (1998) Int J Prosthodont , vol.11 , pp. 580-590
    • Lin, M.T.1    Sy-Muñoz, J.2    Muñoz, C.A.3
  • 34
    • 15944372291 scopus 로고    scopus 로고
    • Influence of firing cycles on the distortion of 3 all-ceramic crown systems
    • Balkaya MC, Cinar A, Pamuk S: Influence of firing cycles on the distortion of 3 all-ceramic crown systems. J Prosthet Dent 2005;93:346-355.
    • (2005) J Prosthet Dent , vol.93 , pp. 346-355
    • Balkaya, M.C.1    Cinar, A.2    Pamuk, S.3
  • 35
    • 77954356003 scopus 로고    scopus 로고
    • Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses
    • Kohorst P, Brinkmann H, Dittmer MP, et al: Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil 2010;37:283-291.
    • (2010) J Oral Rehabil , vol.37 , pp. 283-291
    • Kohorst, P.1    Brinkmann, H.2    Dittmer, M.P.3
  • 36
    • 33845346140 scopus 로고    scopus 로고
    • Evaluation of the marginal fit of the three margin designs of resin composite crowns using CAD/CAM
    • Tsitrou EA, Northeast SE, Noort R van: Evaluation of the marginal fit of the three margin designs of resin composite crowns using CAD/CAM. J Dent 2007;35:68-73.
    • (2007) J Dent , vol.35 , pp. 68-73
    • Tsitrou, E.A.1    Northeast, S.E.2    Noort, R.3
  • 37
    • 0013890346 scopus 로고
    • Marginal fit of gold inlay casting
    • Christensen GJ: Marginal fit of gold inlay casting. J Prosthet Dent 1966;16:297-305.
    • (1966) J Prosthet Dent , vol.16 , pp. 297-305
    • Christensen, G.J.1
  • 38
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • McLean JW, Fraunhofer JA von: The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-111.
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    Fraunhofer, J.2
  • 39
    • 0030208224 scopus 로고    scopus 로고
    • Accuracy of machine milling and spark erosion with a CAD/CAM system
    • Andersson M, Carlsson L, Persson M, et al: Accuracy of machine milling and spark erosion with a CAD/CAM system. J Prosthet Dent 1996;76:187-193.
    • (1996) J Prosthet Dent , vol.76 , pp. 187-193
    • Andersson, M.1    Carlsson, L.2    Persson, M.3
  • 41
    • 0036518215 scopus 로고    scopus 로고
    • Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns
    • Mou S, Chai T, Wang J, et al: Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns. J Prosthet Dent 2002;87:248-255.
    • (2002) J Prosthet Dent , vol.87 , pp. 248-255
    • Mou, S.1    Chai, T.2    Wang, J.3
  • 42
    • 0141721827 scopus 로고    scopus 로고
    • Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns
    • Nakamura T, Dei N, Kojima T, et al: Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns. Int J Prosthodont 2003;16:244-248.
    • (2003) Int J Prosthodont , vol.16 , pp. 244-248
    • Nakamura, T.1    Dei, N.2    Kojima, T.3
  • 43
    • 0032112338 scopus 로고    scopus 로고
    • Effects of preparation and luting systems on all-ceramic computer-generated crowns
    • Mörmann WH, Bindl A, Lüthy H, et al: Effects of preparation and luting systems on all-ceramic computer-generated crowns. Int J Prosthodont 1998;11:333-339.
    • (1998) Int J Prosthodont , vol.11 , pp. 333-339
    • Mörmann, W.H.1    Bindl, A.2    Lüthy, H.3
  • 44
    • 0043130574 scopus 로고    scopus 로고
    • Microtensile bond strength testing of luting cements to prefabricated CAD/CAM ceramic and composite blocks
    • Zohairy AA El, Gee A De, Mohsen MM, et al: Microtensile bond strength testing of luting cements to prefabricated CAD/CAM ceramic and composite blocks. Dent Mater 2003;19:575-583.
    • (2003) Dent Mater , vol.19 , pp. 575-583
    • Zohairy, A.E.1    Gee, A.D.2    Mohsen, M.M.3
  • 45
    • 32244437938 scopus 로고    scopus 로고
    • Fracture load of composite resin and feldspathic ceramic CAD/CAM crowns
    • Attia A, Abdelaziz KM, Freitag S, et al: Fracture load of composite resin and feldspathic ceramic CAD/CAM crowns. J Prosthet Dent 2006;95:117-123.
    • (2006) J Prosthet Dent , vol.95 , pp. 117-123
    • Attia, A.1    Abdelaziz, K.M.2    Freitag, S.3
  • 46
    • 20044367673 scopus 로고    scopus 로고
    • Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations
    • Bindl A, Mörmann WH: Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 2005;32:441-447.
    • (2005) J Oral Rehabil , vol.32 , pp. 441-447
    • Bindl, A.1    Mörmann, W.H.2
  • 47
    • 85005747522 scopus 로고
    • Interfacial gaps of resin cemented ceramic inlays
    • Sorensen JA, Munksgaard EC: Interfacial gaps of resin cemented ceramic inlays. Eur J Oral Sci 1995;103:116-120.
    • (1995) Eur J Oral Sci , vol.103 , pp. 116-120
    • Sorensen, J.A.1    Munksgaard, E.C.2
  • 48
    • 0030179445 scopus 로고    scopus 로고
    • Influence of film thickness on joint bend strength of a ceramic/resin composite joint
    • Molin MK, Karlsson SL, Kristiansen MS: Influence of film thickness on joint bend strength of a ceramic/resin composite joint. Dent Mater 1996;12:245-249.
    • (1996) Dent Mater , vol.12 , pp. 245-249
    • Molin, M.K.1    Karlsson, S.L.2    Kristiansen, M.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.