-
1
-
-
84937701956
-
Treatment of the patient with gummy smile in conjunction with digital smile approach
-
Arias D.M., Trushkowsky R.D., Brea L.M., David S.B. Treatment of the patient with gummy smile in conjunction with digital smile approach. Dent Clin North Am 2015, 59(3):703-716.
-
(2015)
Dent Clin North Am
, vol.59
, Issue.3
, pp. 703-716
-
-
Arias, D.M.1
Trushkowsky, R.D.2
Brea, L.M.3
David, S.B.4
-
2
-
-
84976589991
-
Predictable restorative work flow for computer-aided design/computer-aided manufacture-fabricated ceramic veneers utilizing a virtual smile design principle
-
Lin W.S., Zandinejad A., Metz M.J., Harris B.T., Morton D. Predictable restorative work flow for computer-aided design/computer-aided manufacture-fabricated ceramic veneers utilizing a virtual smile design principle. Oper Dent 2015, 40(4):357-363.
-
(2015)
Oper Dent
, vol.40
, Issue.4
, pp. 357-363
-
-
Lin, W.S.1
Zandinejad, A.2
Metz, M.J.3
Harris, B.T.4
Morton, D.5
-
3
-
-
84888148416
-
Digital imaging and fabrication
-
Zandparsa R. Digital imaging and fabrication. Dent Clin North Am 2014, 58(1):135-158.
-
(2014)
Dent Clin North Am
, vol.58
, Issue.1
, pp. 135-158
-
-
Zandparsa, R.1
-
4
-
-
84949934777
-
CEREC CAD/CAM chairside system
-
Sannino G., Germano F., Arcuri L., Bigelli E., Arcuri C., Barlattani A. CEREC CAD/CAM chairside system. Oral Implantol (Rome) 2015, 7(3):57-70.
-
(2015)
Oral Implantol (Rome)
, vol.7
, Issue.3
, pp. 57-70
-
-
Sannino, G.1
Germano, F.2
Arcuri, L.3
Bigelli, E.4
Arcuri, C.5
Barlattani, A.6
-
5
-
-
84893205192
-
Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes
-
Yuzbasioglu E., Kurt H., Turunc R., Bilir H. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 2014, 30(14):10.
-
(2014)
BMC Oral Health
, vol.30
, Issue.14
, pp. 10
-
-
Yuzbasioglu, E.1
Kurt, H.2
Turunc, R.3
Bilir, H.4
-
6
-
-
84902126764
-
The time efficiency of intraoral scanners: an in vitro comparative study
-
Patzelt S.B., Lamprinos C., Stampf S., Att W. The time efficiency of intraoral scanners: an in vitro comparative study. J Am Dent Assoc 2014, 145(6):542-551.
-
(2014)
J Am Dent Assoc
, vol.145
, Issue.6
, pp. 542-551
-
-
Patzelt, S.B.1
Lamprinos, C.2
Stampf, S.3
Att, W.4
-
7
-
-
84906810284
-
A comparison of the marginal fit of crowns fabricated with digital and conventional methods
-
Ng J., Ruse D., Wyatt C. A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent 2014, 112(3):555-560.
-
(2014)
J Prosthet Dent
, vol.112
, Issue.3
, pp. 555-560
-
-
Ng, J.1
Ruse, D.2
Wyatt, C.3
-
8
-
-
84922798743
-
Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology
-
Pradíes G., Zarauz C., Valverde A., Ferreiroa A., Martínez-Rus F. Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent 2015, 43(2):201-208.
-
(2015)
J Dent
, vol.43
, Issue.2
, pp. 201-208
-
-
Pradíes, G.1
Zarauz, C.2
Valverde, A.3
Ferreiroa, A.4
Martínez-Rus, F.5
-
9
-
-
84963976557
-
Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial
-
June
-
Ahrberg D., Lauer H.C., Ahrberg M., Weigl P. Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial. Clin Oral Investig 2015, (June).
-
(2015)
Clin Oral Investig
-
-
Ahrberg, D.1
Lauer, H.C.2
Ahrberg, M.3
Weigl, P.4
-
10
-
-
84919952628
-
3D and 2D marginal fit of pressed and CAD/CAM lithium disilicate crowns made from digital and conventional impressions
-
Anadioti E., Aquilino S.A., Gratton D.G., Holloway J.A., Denry I., Thomas G.W., et al. 3D and 2D marginal fit of pressed and CAD/CAM lithium disilicate crowns made from digital and conventional impressions. J Prosthodont 2014, 23(8):610-617.
-
(2014)
J Prosthodont
, vol.23
, Issue.8
, pp. 610-617
-
-
Anadioti, E.1
Aquilino, S.A.2
Gratton, D.G.3
Holloway, J.A.4
Denry, I.5
Thomas, G.W.6
-
11
-
-
84912080727
-
The fit of crowns produced using digital impression systems
-
Vennerstrom M., Fakhary M., Von Steyern P.V. The fit of crowns produced using digital impression systems. Swed Dent J 2014, 38(3):101-110.
-
(2014)
Swed Dent J
, vol.38
, Issue.3
, pp. 101-110
-
-
Vennerstrom, M.1
Fakhary, M.2
Von Steyern, P.V.3
-
12
-
-
84888621212
-
Diagnostic accuracy of impression-free digital models
-
Akyalcin S., Cozad B.E., English J.D., Colville C.D., Laman S. Diagnostic accuracy of impression-free digital models. Am J Orthod Dentofacial Orthop 2013, 144(6):916-922.
-
(2013)
Am J Orthod Dentofacial Orthop
, vol.144
, Issue.6
, pp. 916-922
-
-
Akyalcin, S.1
Cozad, B.E.2
English, J.D.3
Colville, C.D.4
Laman, S.5
-
13
-
-
84855657546
-
Virtual articulator for the analysis of dental occlusion: an update
-
Maestre-Ferrín L., Romero-Millán J., Peñarrocha-Oltra D., Peñarrocha-Diago M. Virtual articulator for the analysis of dental occlusion: an update. Med Oral Patol Oral Cir Bucal 2012, 17(1):e160-e163.
-
(2012)
Med Oral Patol Oral Cir Bucal
, vol.17
, Issue.1
, pp. e160-e163
-
-
Maestre-Ferrín, L.1
Romero-Millán, J.2
Peñarrocha-Oltra, D.3
Peñarrocha-Diago, M.4
-
14
-
-
84925156144
-
Comparison of the accuracy of a 3-dimensional virtual method and the conventional method for transferring the maxillary cast to a virtual articulator
-
Solaberrieta E., Mínguez R., Barrenetxea L., Otegi J.R., Szentpétery A. Comparison of the accuracy of a 3-dimensional virtual method and the conventional method for transferring the maxillary cast to a virtual articulator. J Prosthet Dent 2015, 113(3):191-197.
-
(2015)
J Prosthet Dent
, vol.113
, Issue.3
, pp. 191-197
-
-
Solaberrieta, E.1
Mínguez, R.2
Barrenetxea, L.3
Otegi, J.R.4
Szentpétery, A.5
-
15
-
-
84879092363
-
Direct transfer of the position of digitized casts to a virtual articulator
-
Solaberrieta E., Mínguez R., Barrenetxea L., Etxaniz O. Direct transfer of the position of digitized casts to a virtual articulator. J Prosthet Dent 2013, 109(6):411-414.
-
(2013)
J Prosthet Dent
, vol.109
, Issue.6
, pp. 411-414
-
-
Solaberrieta, E.1
Mínguez, R.2
Barrenetxea, L.3
Etxaniz, O.4
-
16
-
-
84921905359
-
Improved digital transfer of the maxillary cast to a virtual articulator
-
Solaberrieta E., Otegi J.R., Mínguez R., Etxaniz O. Improved digital transfer of the maxillary cast to a virtual articulator. J Prosthet Dent 2014, 112(4):921-924.
-
(2014)
J Prosthet Dent
, vol.112
, Issue.4
, pp. 921-924
-
-
Solaberrieta, E.1
Otegi, J.R.2
Mínguez, R.3
Etxaniz, O.4
-
17
-
-
84899450590
-
Computer-aided dental prostheses construction using reverse engineering
-
Solaberrieta E., Minguez R., Barrenetxea L., Sierra E., Etxaniz O. Computer-aided dental prostheses construction using reverse engineering. Comput Methods Biomech Biomed Eng 2014, 17(12):1335-1346.
-
(2014)
Comput Methods Biomech Biomed Eng
, vol.17
, Issue.12
, pp. 1335-1346
-
-
Solaberrieta, E.1
Minguez, R.2
Barrenetxea, L.3
Sierra, E.4
Etxaniz, O.5
-
18
-
-
84905111277
-
The role of virtual articulator in prosthetic and restorative dentistry
-
Koralakunte P.R., Aljanakh M. The role of virtual articulator in prosthetic and restorative dentistry. J Clin Diagn Res 2014, 8(7):ZE25-ZE28.
-
(2014)
J Clin Diagn Res
, vol.8
, Issue.7
, pp. ZE25-ZE28
-
-
Koralakunte, P.R.1
Aljanakh, M.2
-
19
-
-
84937737934
-
Comparison of a conventional and virtual occlusal record
-
Solaberrieta E., Otegi J.R., Goicoechea N., Brizuela A., Pradies G. Comparison of a conventional and virtual occlusal record. J Prosthet Dent 2015, 114(1):92-97.
-
(2015)
J Prosthet Dent
, vol.114
, Issue.1
, pp. 92-97
-
-
Solaberrieta, E.1
Otegi, J.R.2
Goicoechea, N.3
Brizuela, A.4
Pradies, G.5
-
21
-
-
84929939744
-
Understanding dental CAD/CAM for restorations - the digital workflow from a mechanical engineering viewpoint
-
Tapie L., Lebon N., Mawussi B., Fron Chabouis H., Duret F., Attal J.P. Understanding dental CAD/CAM for restorations - the digital workflow from a mechanical engineering viewpoint. Int J Comput Dent 2015, 18(1):21-44.
-
(2015)
Int J Comput Dent
, vol.18
, Issue.1
, pp. 21-44
-
-
Tapie, L.1
Lebon, N.2
Mawussi, B.3
Fron Chabouis, H.4
Duret, F.5
Attal, J.P.6
-
22
-
-
84938689051
-
Intraoral scanning systems - a current overview
-
Zimmermann M., Mehl A., Mörmann W.H., Reich S. Intraoral scanning systems - a current overview. Int J Comput Dent 2015, 18(2):101-129.
-
(2015)
Int J Comput Dent
, vol.18
, Issue.2
, pp. 101-129
-
-
Zimmermann, M.1
Mehl, A.2
Mörmann, W.H.3
Reich, S.4
-
23
-
-
84933678682
-
Intraoral digital impression technique: a review
-
Ting-Shu S., Jian S. Intraoral digital impression technique: a review. J Prosthodont 2015, 24(4):313-321.
-
(2015)
J Prosthodont
, vol.24
, Issue.4
, pp. 313-321
-
-
Ting-Shu, S.1
Jian, S.2
-
24
-
-
84976585883
-
Maxillary and mandibular rehabilitation in the esthetic zone using a digital impression technique and CAD/CAM-fabricated prostheses: a multidisciplinary clinical report
-
Abdel-Azim T., Zandinejad A., Metz M., Morton D. Maxillary and mandibular rehabilitation in the esthetic zone using a digital impression technique and CAD/CAM-fabricated prostheses: a multidisciplinary clinical report. Oper Dent 2015, 40(4):350-356.
-
(2015)
Oper Dent
, vol.40
, Issue.4
, pp. 350-356
-
-
Abdel-Azim, T.1
Zandinejad, A.2
Metz, M.3
Morton, D.4
-
25
-
-
84940000878
-
Tooth preparation for full-coverage restorations - a literature review
-
Podhorsky A., Rehmann P., Wöstmann B. Tooth preparation for full-coverage restorations - a literature review. Clin Oral Investig 2015, 19(5):959-968.
-
(2015)
Clin Oral Investig
, vol.19
, Issue.5
, pp. 959-968
-
-
Podhorsky, A.1
Rehmann, P.2
Wöstmann, B.3
-
26
-
-
84921911862
-
Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns
-
Alghazzawi T., Alsamadani K., Lemons J., Liu P.R., Essig M., Bartolucci A., et al. Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns. J Am Dent Assoc 2015, 146(2):111-120.
-
(2015)
J Am Dent Assoc
, vol.146
, Issue.2
, pp. 111-120
-
-
Alghazzawi, T.1
Alsamadani, K.2
Lemons, J.3
Liu, P.R.4
Essig, M.5
Bartolucci, A.6
-
27
-
-
84929516927
-
Fabrication of lithium silicate ceramic veneers with a CAD/CAM approach: a clinical report of cleidocranial dysplasia
-
da Cunha L.F., Mukai E., Hamerschmitt R.M., Correr G.M. Fabrication of lithium silicate ceramic veneers with a CAD/CAM approach: a clinical report of cleidocranial dysplasia. J Prosthet Dent 2015, 113(5):355-359.
-
(2015)
J Prosthet Dent
, vol.113
, Issue.5
, pp. 355-359
-
-
da Cunha, L.F.1
Mukai, E.2
Hamerschmitt, R.M.3
Correr, G.M.4
-
28
-
-
84856747037
-
Minimally invasive lithium disilicate ceramic veneers fabricated using chairside CAD/CAM: a clinical report
-
Schmitter M., Seydler B.B. Minimally invasive lithium disilicate ceramic veneers fabricated using chairside CAD/CAM: a clinical report. J Prosthet Dent 2012, 107(2):71-74.
-
(2012)
J Prosthet Dent
, vol.107
, Issue.2
, pp. 71-74
-
-
Schmitter, M.1
Seydler, B.B.2
-
29
-
-
84879160361
-
A new, hybrid material for minimally invasive restorations in clinical use
-
Kurbad A., Kurbad S. A new, hybrid material for minimally invasive restorations in clinical use. Int J Comput Dent 2013, 16(1):69-79.
-
(2013)
Int J Comput Dent
, vol.16
, Issue.1
, pp. 69-79
-
-
Kurbad, A.1
Kurbad, S.2
-
30
-
-
84906930282
-
Impressionless implant-supported restorations with Cerec 4.2
-
Rauscher O. Impressionless implant-supported restorations with Cerec 4.2. Int J Comput Dent 2014, 17(2):159-168.
-
(2014)
Int J Comput Dent
, vol.17
, Issue.2
, pp. 159-168
-
-
Rauscher, O.1
-
31
-
-
84875421618
-
The use of a scannable impression coping and digital impression technique to fabricate a customized anatomic abutment and zirconia restoration in the esthetic zone
-
Lin W.S., Harris B.T., Morton D. The use of a scannable impression coping and digital impression technique to fabricate a customized anatomic abutment and zirconia restoration in the esthetic zone. J Prosthet Dent 2013, 109(3):187-191.
-
(2013)
J Prosthet Dent
, vol.109
, Issue.3
, pp. 187-191
-
-
Lin, W.S.1
Harris, B.T.2
Morton, D.3
-
32
-
-
84875994171
-
Using digitally coded healing abutments and an intraoral scanner to fabricate implant-supported, cement-retained restorations
-
Nayyar N., Yilmaz B., McGlumphy E. Using digitally coded healing abutments and an intraoral scanner to fabricate implant-supported, cement-retained restorations. J Prosthet Dent 2013, 109(4):210-215.
-
(2013)
J Prosthet Dent
, vol.109
, Issue.4
, pp. 210-215
-
-
Nayyar, N.1
Yilmaz, B.2
McGlumphy, E.3
-
33
-
-
84881349571
-
An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations
-
Al-Abdullah K., Zandparsa R., Finkelman M., Hirayama H. An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations. J Prosthet Dent 2013, 110(2):90-100.
-
(2013)
J Prosthet Dent
, vol.110
, Issue.2
, pp. 90-100
-
-
Al-Abdullah, K.1
Zandparsa, R.2
Finkelman, M.3
Hirayama, H.4
-
34
-
-
84933055458
-
Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions
-
Anadioti E., Aquilino S.A., Gratton D.G., Holloway J.A., Denry I.L., Thomas G.W., et al. Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions. J Prosthet Dent 2015, 113(4):304-309.
-
(2015)
J Prosthet Dent
, vol.113
, Issue.4
, pp. 304-309
-
-
Anadioti, E.1
Aquilino, S.A.2
Gratton, D.G.3
Holloway, J.A.4
Denry, I.L.5
Thomas, G.W.6
-
35
-
-
84911373544
-
Accuracy of computer-aided design/computer-aided manufacturing-generated dental casts based on intraoral scanner data
-
Patzelt S.B., Bishti S., Stampf S., Att W. Accuracy of computer-aided design/computer-aided manufacturing-generated dental casts based on intraoral scanner data. J Am Dent Assoc 2014, 145(11):1133-1140.
-
(2014)
J Am Dent Assoc
, vol.145
, Issue.11
, pp. 1133-1140
-
-
Patzelt, S.B.1
Bishti, S.2
Stampf, S.3
Att, W.4
-
36
-
-
84946165814
-
Using zirconia-based prosthesis in a complete-mouth reconstruction treatment for worn dentition with the altered vertical dimension of occlusion
-
Nam J., Tokutomi H. Using zirconia-based prosthesis in a complete-mouth reconstruction treatment for worn dentition with the altered vertical dimension of occlusion. J Prosthet Dent 2015, 113(2):81-85.
-
(2015)
J Prosthet Dent
, vol.113
, Issue.2
, pp. 81-85
-
-
Nam, J.1
Tokutomi, H.2
-
37
-
-
84903456224
-
Complete mouth implant rehabilitation with a zirconia ceramic system: a clinical report
-
Mehra M., Vahidi F. Complete mouth implant rehabilitation with a zirconia ceramic system: a clinical report. J Prosthet Dent 2014, 112(1):1-4.
-
(2014)
J Prosthet Dent
, vol.112
, Issue.1
, pp. 1-4
-
-
Mehra, M.1
Vahidi, F.2
-
38
-
-
84886412061
-
Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner
-
Flügge T.V., Schlager S., Nelson K., Nahles S., Metzger M.C. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop 2013, 144(3):471-478.
-
(2013)
Am J Orthod Dentofacial Orthop
, vol.144
, Issue.3
, pp. 471-478
-
-
Flügge, T.V.1
Schlager, S.2
Nelson, K.3
Nahles, S.4
Metzger, M.C.5
-
39
-
-
84938418784
-
Incorporating digital scans of diagnostic casts into computed tomography for virtual implant treatment planning
-
Yilmaz B. Incorporating digital scans of diagnostic casts into computed tomography for virtual implant treatment planning. J Prosthet Dent 2015, 114(2):178-181.
-
(2015)
J Prosthet Dent
, vol.114
, Issue.2
, pp. 178-181
-
-
Yilmaz, B.1
-
40
-
-
84355161961
-
The future of dental devices is digital
-
Van Noort R. The future of dental devices is digital. Dent Mater 2012, 28(1):3-12.
-
(2012)
Dent Mater
, vol.28
, Issue.1
, pp. 3-12
-
-
Van Noort, R.1
-
41
-
-
84949546633
-
Rapid prototyping technologies and their applications in prosthodontics: a review of Literature
-
Torabi K., Farjood E., Hamedani S. Rapid prototyping technologies and their applications in prosthodontics: a review of Literature. J Dent (Shiraz) 2015, 16(1):1-9.
-
(2015)
J Dent (Shiraz)
, vol.16
, Issue.1
, pp. 1-9
-
-
Torabi, K.1
Farjood, E.2
Hamedani, S.3
-
42
-
-
84905235456
-
Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique
-
Mously H.A., Finkelman M., Zandparsa R., Hirayama H. Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique. J Prosthet Dent 2014, 112(2):249-256.
-
(2014)
J Prosthet Dent
, vol.112
, Issue.2
, pp. 249-256
-
-
Mously, H.A.1
Finkelman, M.2
Zandparsa, R.3
Hirayama, H.4
-
43
-
-
84900012973
-
Trends in computer-aided manufacturing in prosthodontics: a review of the available streams
-
Abduo J., Lyons K., Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. Int J Dent 2014, 2014:783948.
-
(2014)
Int J Dent
, vol.2014
, pp. 783948
-
-
Abduo, J.1
Lyons, K.2
Bennamoun, M.3
-
44
-
-
84912128995
-
A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes
-
Bosch G., Ender A., Mehl A. A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes. J Prosthet Dent 2014, 112(6):1425-1431.
-
(2014)
J Prosthet Dent
, vol.112
, Issue.6
, pp. 1425-1431
-
-
Bosch, G.1
Ender, A.2
Mehl, A.3
-
45
-
-
79952283407
-
The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study
-
Örtorp A., Jönsson D., Mouhsen A., Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dent Mater 2011, 27(4):356-363.
-
(2011)
Dent Mater
, vol.27
, Issue.4
, pp. 356-363
-
-
Örtorp, A.1
Jönsson, D.2
Mouhsen, A.3
Vult von Steyern, P.4
-
46
-
-
54049092526
-
A comparison of plaster, digital and reconstructed study model accuracy
-
Keating A.P., Knox J., Bibb R., Zhurov A.I. A comparison of plaster, digital and reconstructed study model accuracy. J Orthod 2008, 35(3):191-201.
-
(2008)
J Orthod
, vol.35
, Issue.3
, pp. 191-201
-
-
Keating, A.P.1
Knox, J.2
Bibb, R.3
Zhurov, A.I.4
-
47
-
-
84896466603
-
Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique
-
Kim J.H., Kim K.B., Kim W.C., Kim J.H., Kim H.Y. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique. Korean J Orthod 2014, 44(2):69-76.
-
(2014)
Korean J Orthod
, vol.44
, Issue.2
, pp. 69-76
-
-
Kim, J.H.1
Kim, K.B.2
Kim, W.C.3
Kim, J.H.4
Kim, H.Y.5
-
48
-
-
84902576760
-
Comparison of five-axis milling and rapid prototyping for implant surgical templates
-
Park J.M., Yi T.K., Koak J.Y., Kim S.K., Park E.J., Heo S.J. Comparison of five-axis milling and rapid prototyping for implant surgical templates. Int J Oral Maxillofac Implants 2014, 29(2):374-383.
-
(2014)
Int J Oral Maxillofac Implants
, vol.29
, Issue.2
, pp. 374-383
-
-
Park, J.M.1
Yi, T.K.2
Koak, J.Y.3
Kim, S.K.4
Park, E.J.5
Heo, S.J.6
-
49
-
-
84879072054
-
Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives
-
Bidra A.S., Taylor T.D., Agar J.R. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013, 109(6):361-366.
-
(2013)
J Prosthet Dent
, vol.109
, Issue.6
, pp. 361-366
-
-
Bidra, A.S.1
Taylor, T.D.2
Agar, J.R.3
-
51
-
-
84882945903
-
CAD/CAM complete dentures: a review of two commercial fabrication systems
-
Kattadiyil M.T., Goodacre C.J., Baba N.Z. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc 2013, 41(6):407-416.
-
(2013)
J Calif Dent Assoc
, vol.41
, Issue.6
, pp. 407-416
-
-
Kattadiyil, M.T.1
Goodacre, C.J.2
Baba, N.Z.3
-
52
-
-
84855567898
-
CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data
-
Goodacre C.J., Garbacea A., Naylor W.P., Daher T., Marchack C.B., Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012, 107(1):34-46.
-
(2012)
J Prosthet Dent
, vol.107
, Issue.1
, pp. 34-46
-
-
Goodacre, C.J.1
Garbacea, A.2
Naylor, W.P.3
Daher, T.4
Marchack, C.B.5
Lowry, J.6
-
53
-
-
84899456764
-
Fabricating complete dentures with CAD/CAM technology
-
Infante L., Yilmaz B., McGlumphy E., Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent 2014, 111(5):351-355.
-
(2014)
J Prosthet Dent
, vol.111
, Issue.5
, pp. 351-355
-
-
Infante, L.1
Yilmaz, B.2
McGlumphy, E.3
Finger, I.4
-
54
-
-
84918841130
-
The 2-visit CAD-CAM implant-retained overdenture: a clinical report
-
Bidra A.S. The 2-visit CAD-CAM implant-retained overdenture: a clinical report. J Oral Implantol 2014, 40(6):722-728.
-
(2014)
J Oral Implantol
, vol.40
, Issue.6
, pp. 722-728
-
-
Bidra, A.S.1
-
55
-
-
84903397547
-
Effects of offset values for artificial teeth positions in CAD/CAM complete denture
-
Yamamoto S., Kanazawa M., Iwaki M., Jokanovic A., Minakuchi S. Effects of offset values for artificial teeth positions in CAD/CAM complete denture. Comput Biol Med 2014, 52:1-7.
-
(2014)
Comput Biol Med
, vol.52
, pp. 1-7
-
-
Yamamoto, S.1
Kanazawa, M.2
Iwaki, M.3
Jokanovic, A.4
Minakuchi, S.5
-
56
-
-
57449084616
-
High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - a new fabrication mode for all-ceramic restorations
-
Beuer F., Schweiger J., Eichberger M., Kappert H.F., Gernet W., Edelhoff D. High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - a new fabrication mode for all-ceramic restorations. Dent Mater 2009, 25(1):121-128.
-
(2009)
Dent Mater
, vol.25
, Issue.1
, pp. 121-128
-
-
Beuer, F.1
Schweiger, J.2
Eichberger, M.3
Kappert, H.F.4
Gernet, W.5
Edelhoff, D.6
-
57
-
-
84919351263
-
Digital veneering system enhances microtensile bond strength at zirconia core-veneer interface
-
Kim K.Y., Kwon T.K., Kang T.J., Yang J.H., Lee S.J., Yeo I.S. Digital veneering system enhances microtensile bond strength at zirconia core-veneer interface. Dent Mater J 2014, 33(6):792-798.
-
(2014)
Dent Mater J
, vol.33
, Issue.6
, pp. 792-798
-
-
Kim, K.Y.1
Kwon, T.K.2
Kang, T.J.3
Yang, J.H.4
Lee, S.J.5
Yeo, I.S.6
-
58
-
-
84927699102
-
Microtensile bond strength of lithium disilicate to zirconia with the CAD-on technique
-
Renda J.J., Harding A.B., Bailey C.W., Guillory V.L., Vandewalle K.S. Microtensile bond strength of lithium disilicate to zirconia with the CAD-on technique. J Prosthodont 2015, 24(3):188-193.
-
(2015)
J Prosthodont
, vol.24
, Issue.3
, pp. 188-193
-
-
Renda, J.J.1
Harding, A.B.2
Bailey, C.W.3
Guillory, V.L.4
Vandewalle, K.S.5
-
59
-
-
84889078508
-
Recent advances in dental optics - Part I: 3D intraoral scanners for restorative dentistry
-
Logozzo S., Zanetti E.M., Franceschini G., Kilpelä A., Mäkynen A. Recent advances in dental optics - Part I: 3D intraoral scanners for restorative dentistry. Opt Laser Eng 2014, 54:203-221.
-
(2014)
Opt Laser Eng
, vol.54
, pp. 203-221
-
-
Logozzo, S.1
Zanetti, E.M.2
Franceschini, G.3
Kilpelä, A.4
Mäkynen, A.5
-
60
-
-
84889096467
-
Recent advances in dental optics-Part II: Experimental tests for a new intraoral scanner
-
Logozzo S., Kilpelä A., Mäkynen A., Zanetti E.M., Franceschini G. Recent advances in dental optics-Part II: Experimental tests for a new intraoral scanner. Opt Laser Eng 2014, 54:187-196.
-
(2014)
Opt Laser Eng
, vol.54
, pp. 187-196
-
-
Logozzo, S.1
Kilpelä, A.2
Mäkynen, A.3
Zanetti, E.M.4
Franceschini, G.5
-
61
-
-
85017306032
-
In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
-
Ender A., Mehl A. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions. Quintessence Int 2015, 46(1):9-17.
-
(2015)
Quintessence Int
, vol.46
, Issue.1
, pp. 9-17
-
-
Ender, A.1
Mehl, A.2
-
62
-
-
84902765111
-
Accuracy of full-arch scans using intraoral scanners
-
Patzelt S.B., Emmanouilidi A., Stampf S., Strub J.R., Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig 2014, 18(6):1687-1694.
-
(2014)
Clin Oral Investig
, vol.18
, Issue.6
, pp. 1687-1694
-
-
Patzelt, S.B.1
Emmanouilidi, A.2
Stampf, S.3
Strub, J.R.4
Att, W.5
-
63
-
-
84873578014
-
Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision
-
Ender A., Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent 2013, 109(2):121-128.
-
(2013)
J Prosthet Dent
, vol.109
, Issue.2
, pp. 121-128
-
-
Ender, A.1
Mehl, A.2
-
64
-
-
84912077800
-
Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis
-
Nedelcu R.G., Persson A.S. Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis. J Prosthet Dent 2014, 112(6):1461-1471.
-
(2014)
J Prosthet Dent
, vol.112
, Issue.6
, pp. 1461-1471
-
-
Nedelcu, R.G.1
Persson, A.S.2
-
65
-
-
84918828929
-
Fit of CAD/CAM implant frameworks: a comprehensive review
-
Abduo J. Fit of CAD/CAM implant frameworks: a comprehensive review. J Oral Implantol 2014, 40(6):758-766.
-
(2014)
J Oral Implantol
, vol.40
, Issue.6
, pp. 758-766
-
-
Abduo, J.1
-
66
-
-
84919838236
-
High-frequency ultrasound as an option for scanning of prepared teeth: an in vitro study
-
Chuembou Pekam F., Marotti J., Wolfart S., Tinschert J., Radermacher K., Heger S. High-frequency ultrasound as an option for scanning of prepared teeth: an in vitro study. Ultrasound Med Biol 2015, 41(1):309-316.
-
(2015)
Ultrasound Med Biol
, vol.41
, Issue.1
, pp. 309-316
-
-
Chuembou Pekam, F.1
Marotti, J.2
Wolfart, S.3
Tinschert, J.4
Radermacher, K.5
Heger, S.6
-
67
-
-
84925547892
-
Soft tissue-preserving computer-aided impression: a novel concept using ultrasonic 3D-scanning
-
Vollborn T., Habor D., Pekam F.C., Heger S., Marotti J., Reich S., et al. Soft tissue-preserving computer-aided impression: a novel concept using ultrasonic 3D-scanning. Int J Comput Dent 2014, 17(4):277-296.
-
(2014)
Int J Comput Dent
, vol.17
, Issue.4
, pp. 277-296
-
-
Vollborn, T.1
Habor, D.2
Pekam, F.C.3
Heger, S.4
Marotti, J.5
Reich, S.6
-
69
-
-
68249140148
-
Direct inkjet printing of dental prostheses made of zirconia
-
Ebert J., Ozkol E., Zeichner A., Uibel K., Weiss O., Koops U., et al. Direct inkjet printing of dental prostheses made of zirconia. J Dent Res 2009, 88(7):673-676.
-
(2009)
J Dent Res
, vol.88
, Issue.7
, pp. 673-676
-
-
Ebert, J.1
Ozkol, E.2
Zeichner, A.3
Uibel, K.4
Weiss, O.5
Koops, U.6
|