메뉴 건너뛰기




Volumn 34, Issue 1, 2015, Pages 7-12

Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types

Author keywords

CAD CAM; FDPs; Fracture load; PEEK C; Press technique

Indexed keywords

BRITTLE FRACTURE; COMPUTER AIDED DESIGN; DENTAL PROSTHESES; FRACTURE; PELLETIZING; REINFORCEMENT;

EID: 84922119757     PISSN: 02874547     EISSN: 18811361     Source Type: Journal    
DOI: 10.4012/dmj.2013-345     Document Type: Article
Times cited : (128)

References (30)
  • 2
    • 77956253617 scopus 로고    scopus 로고
    • In vitro fatigue resistance of CAD/CAM resin composite and ceramic posterior occlusal veneers
    • Magne P, Schlichting LH, Maia HP, Baratieri LN. In vitro fatigue resistance of CAD/CAM resin composite and ceramic posterior occlusal veneers. J Prosthet Dent 2010; 104: 149-157.
    • (2010) J Prosthet Dent , vol.104 , pp. 149-157
    • Magne, P.1    Schlichting, L.H.2    Maia, H.P.3    Baratieri, L.N.4
  • 3
    • 79952281326 scopus 로고    scopus 로고
    • Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations
    • Alt V, Hannig M, Wöstmann B, Balkenhol M. Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations. Dent Mater 2011; 27: 339-347.
    • (2011) Dent Mater , vol.27 , pp. 339-347
    • Alt, V.1    Hannig, M.2    Wöstmann, B.3    Balkenhol, M.4
  • 4
    • 79955021844 scopus 로고    scopus 로고
    • Loadbearing capacity of handmade and computer-aided design-computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite
    • Göncü Başaran E, Ayna E, Vallittu PK, Lassila LVJ. Loadbearing capacity of handmade and computer-aided design-computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite. Acta Odontol Scand 2011; 69: 144-150.
    • (2011) Acta Odontol Scand , vol.69 , pp. 144-150
    • Göncü Başaran, E.1    Ayna, E.2    Vallittu, P.K.3    Lassila, L.V.J.4
  • 5
    • 84861896608 scopus 로고    scopus 로고
    • Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: Effect of aging regimens
    • Stawarczyk B, Ender A, Trottmann A, Özcan M, Fischer J, Hämmerle CH. Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: Effect of aging regimens. Clin Oral Investig 2012; 16: 1669-1677.
    • (2012) Clin Oral Investig , vol.16 , pp. 1669-1677
    • Stawarczyk, B.1    Ender, A.2    Trottmann, A.3    Özcan, M.4    Fischer, J.5    Hämmerle, C.H.6
  • 7
    • 84861863388 scopus 로고    scopus 로고
    • Discoloration of manually fabricated resins and industrially fabricated CAD/CAM blocks versus glassceramic: Effect of storage media, duration, and subsequent polishing
    • Stawarczyk B, Sener B, Trottmann A, Roos M, Özcan M, Hämmerle CH. Discoloration of manually fabricated resins and industrially fabricated CAD/CAM blocks versus glassceramic: Effect of storage media, duration, and subsequent polishing. Dent Mater J 2012; 31: 377-383.
    • (2012) Dent Mater J , vol.31 , pp. 377-383
    • Stawarczyk, B.1    Sener, B.2    Trottmann, A.3    Roos, M.4    Özcan, M.5    Hämmerle, C.H.6
  • 9
    • 29144453862 scopus 로고    scopus 로고
    • The clinical performance of CAD/CAM-generated composite inlays
    • Fasbinder DJ, Dennison JB, Heys DR, Lampe K. The clinical performance of CAD/CAM-generated composite inlays. J Am Dent Assoc 2005; 136: 1714-1723.
    • (2005) J Am Dent Assoc , vol.136 , pp. 1714-1723
    • Fasbinder, D.J.1    Dennison, J.B.2    Heys, D.R.3    Lampe, K.4
  • 10
    • 77949880038 scopus 로고    scopus 로고
    • Adhesively luted, metal-free composite crowns after five years
    • Lehmann F, Spiegl K, Eickemeyer G, Rammelsberg P. Adhesively luted, metal-free composite crowns after five years. J Adhes Dent 2009; 11: 493-498.
    • (2009) J Adhes Dent , vol.11 , pp. 493-498
    • Lehmann, F.1    Spiegl, K.2    Eickemeyer, G.3    Rammelsberg, P.4
  • 11
    • 77955887282 scopus 로고    scopus 로고
    • Computeraided designed/computer-assisted manufactured composite resin versus ceramic single-tooth restorations: A 3-year clinical study
    • Vanoorbeek S, Vandamme K, Lijnen I, Naert I. Computeraided designed/computer-assisted manufactured composite resin versus ceramic single-tooth restorations: A 3-year clinical study. Int J Prosthodont 2010; 23: 223-230.
    • (2010) Int J Prosthodont , vol.23 , pp. 223-230
    • Vanoorbeek, S.1    Vandamme, K.2    Lijnen, I.3    Naert, I.4
  • 12
    • 84875279822 scopus 로고    scopus 로고
    • Wear characteristics of current aesthetic dental restorative CAD/CAM materials: Two-body wear, gloss retention, roughness and Martens hardness
    • Mörmann WH, Stawarczyk B, Ender A, Sener B, Attin T, Mehl A. Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness. J Mech Behav Biomed Mater 2013; 20: 113-125.
    • (2013) J Mech Behav Biomed Mater , vol.20 , pp. 113-125
    • Mörmann, W.H.1    Stawarczyk, B.2    Ender, A.3    Sener, B.4    Attin, T.5    Mehl, A.6
  • 14
    • 34548021405 scopus 로고    scopus 로고
    • PEEK biomaterials in trauma, orthopedic, and spinal implants
    • Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 2007; 28: 4845-4869.
    • (2007) Biomaterials , vol.28 , pp. 4845-4869
    • Kurtz, S.M.1    Devine, J.N.2
  • 15
    • 40549084975 scopus 로고    scopus 로고
    • A new transitional abutment for immediate aestehetics and function
    • Tetelman ED, Babbush CA. A new transitional abutment for immediate aestehetics and function. Implant Dent 2008; 17: 51-58.
    • (2008) Implant Dent , vol.17 , pp. 51-58
    • Tetelman, E.D.1    Babbush, C.A.2
  • 17
    • 84870499284 scopus 로고    scopus 로고
    • Fracture strength and failure mode of maxillary implant-supported provisional single crowns: A comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments
    • Santing HJ, Meijer HJ, Raghoebar GM, Ozcan M. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments. Clin Implant Dent Relat Res 2012; 14: 882-889.
    • (2012) Clin Implant Dent Relat Res , vol.14 , pp. 882-889
    • Santing, H.J.1    Meijer, H.J.2    Raghoebar, G.M.3    Ozcan, M.4
  • 18
    • 84857062108 scopus 로고    scopus 로고
    • Retentive forces and fatigue resistance of thermoplastic resin clasps
    • Tannous F, Steiner M, Shahin R, Kern M. Retentive forces and fatigue resistance of thermoplastic resin clasps. Dent Mater 2012; 28: 273-278.
    • (2012) Dent Mater , vol.28 , pp. 273-278
    • Tannous, F.1    Steiner, M.2    Shahin, R.3    Kern, M.4
  • 20
    • 0000859680 scopus 로고
    • A Review of the Weibull Distribution
    • Hallinan AJ. A Review of the Weibull Distribution. J Qual Technol 1993; 25: 85-93.
    • (1993) J Qual Technol , vol.25 , pp. 85-93
    • Hallinan, A.J.1
  • 21
    • 33750534339 scopus 로고    scopus 로고
    • Effect of pontic height on the fracture strength of reinforced interim fixed partial dentures
    • Pfeiffer P, Grube L. Effect of pontic height on the fracture strength of reinforced interim fixed partial dentures. Dent Mater 2006; 22: 1093-1097.
    • (2006) Dent Mater , vol.22 , pp. 1093-1097
    • Pfeiffer, P.1    Grube, L.2
  • 22
    • 84922165714 scopus 로고    scopus 로고
    • New material options for innovation in restorative and prosthetic dentistry
    • Invibio Biomaterial Polymer Solutions. New material options for innovation in restorative and prosthetic dentistry. 2011.
    • (2011) Invibio Biomaterial Polymer Solutions
  • 24
    • 46749105594 scopus 로고    scopus 로고
    • Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/ computer-aided manufacturing (CAM) fabricated materials
    • Beuer F, Steff B, Naumann M, Sorensen JA. Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/ computer-aided manufacturing (CAM) fabricated materials. Eur J Oral Sci 2009; 116: 381-386.
    • (2009) Eur J Oral Sci , vol.116 , pp. 381-386
    • Beuer, F.1    Steff, B.2    Naumann, M.3    Sorensen, J.A.4
  • 25
    • 51849168106 scopus 로고    scopus 로고
    • Fracture force of tooth-tooth-and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments
    • Kolbeck C, Behr M, Rosentritt M, Handel G. Fracture force of tooth-tooth-and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments. Clin Oral Implants Res 2008; 19: 1049-1053.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 1049-1053
    • Kolbeck, C.1    Behr, M.2    Rosentritt, M.3    Handel, G.4
  • 26
    • 84987266075 scopus 로고
    • A statistic distribution function of wide applicability
    • Weibull A. A statistic distribution function of wide applicability. J Appl Mech 1951; 18: 293-297.
    • (1951) J Appl Mech , vol.18 , pp. 293-297
    • Weibull, A.1
  • 27
    • 0742321994 scopus 로고    scopus 로고
    • Finite element and experimental analyses of polymer-based dental bridges reinforced by ceramic bars
    • Fischer H, Weber M, Eck M, Erdrich A, Marx R. Finite element and experimental analyses of polymer-based dental bridges reinforced by ceramic bars. J Biomech 2004; 37: 289-294.
    • (2004) J Biomech , vol.37 , pp. 289-294
    • Fischer, H.1    Weber, M.2    Eck, M.3    Erdrich, A.4    Marx, R.5
  • 28
    • 79959526917 scopus 로고    scopus 로고
    • The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental protheses
    • Mahmood DJ, Linderoth EH, Vult von Steyern P. The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental protheses. Acta Odont Scand 2011; 69: 229-237.
    • (2011) Acta Odont Scand , vol.69 , pp. 229-237
    • Mahmood, D.J.1    Linderoth, E.H.2    Vult von Steyern, P.3
  • 29
    • 0027655860 scopus 로고
    • The fracture resistance of allceramic crowns on supporting structures with different elastic moduli
    • Scherrer SS, de Rijk W.G. The fracture resistance of allceramic crowns on supporting structures with different elastic moduli. Int J Prosthodont 1993; 6: 462-467.
    • (1993) Int J Prosthodont , vol.6 , pp. 462-467
    • Scherrer, S.S.1    de Rijk, W.G.2
  • 30
    • 64549163667 scopus 로고    scopus 로고
    • The influence of framework design on the load-bearing capacity of laboratory-made inlay-retained fibre-reinforced composite fixed dental prostheses
    • Keulemans F, Lassila LV, Garoushi S, Vallittu PK, Kleverlaan CJ, Feilzer AJ. The influence of framework design on the load-bearing capacity of laboratory-made inlay-retained fibre-reinforced composite fixed dental prostheses. J Biomech 2009; 42: 844-849.
    • (2009) J Biomech , vol.42 , pp. 844-849
    • Keulemans, F.1    Lassila, L.V.2    Garoushi, S.3    Vallittu, P.K.4    Kleverlaan, C.J.5    Feilzer, A.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.