메뉴 건너뛰기




Volumn 116, Issue 4, 2008, Pages 381-386

Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials

Author keywords

All ceramic; CAD CAM; Fatigue; FDP; Load bearing capacity

Indexed keywords

ALUMINUM OXIDE; YTTRIA STABILIZED TETRAGONAL ZIRCONIA POLYCRYSTALS CERAMIC; YTTRIA-STABILIZED TETRAGONAL ZIRCONIA POLYCRYSTALS CERAMIC; YTTRIUM; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 46749105594     PISSN: 09098836     EISSN: 16000722     Source Type: Journal    
DOI: 10.1111/j.1600-0722.2008.00551.x     Document Type: Article
Times cited : (60)

References (46)
  • 1
    • 34250851683 scopus 로고    scopus 로고
    • Restoration of the upper dental arch using Lava all-ceramic crown and bridgework
    • Barnfather KD, Brunton PA. Restoration of the upper dental arch using Lava all-ceramic crown and bridgework. Br Dent J 2007 202 : 731 735.
    • (2007) Br Dent J , vol.202 , pp. 731-735
    • Barnfather, K.D.1    Brunton, P.A.2
  • 2
    • 5444219837 scopus 로고    scopus 로고
    • Precision of a CAD/CAM technique for the production of zirconium dioxide copings
    • Coli P, Karlsson S. Precision of a CAD/CAM technique for the production of zirconium dioxide copings. Int J Prosthodont 2004 17 : 577 580.
    • (2004) Int J Prosthodont , vol.17 , pp. 577-580
    • Coli, P.1    Karlsson, S.2
  • 3
    • 12444332060 scopus 로고    scopus 로고
    • Fracture behavior of lithia disilicate- and leucite-based ceramics
    • Della Bona A, Mecholsky JJ Jr, Anusavice KJ. Fracture behavior of lithia disilicate- and leucite-based ceramics. Dent Mater 2004 20 : 956 962.
    • (2004) Dent Mater , vol.20 , pp. 956-962
    • Della Bona, A.1    Mecholsky Jr., J.J.2    Anusavice, K.J.3
  • 4
    • 33644686403 scopus 로고    scopus 로고
    • Guidelines for success with zirconia ceramics: The changing standards
    • Devaud V. Guidelines for success with zirconia ceramics: the changing standards. Pract Proced Aesthet Dent 2005 17 : 508 510.
    • (2005) Pract Proced Aesthet Dent , vol.17 , pp. 508-510
    • Devaud, V.1
  • 5
    • 0036725232 scopus 로고    scopus 로고
    • Retention of selected core materials to zirconia posts
    • Edelhoff D, Sorensen JA. Retention of selected core materials to zirconia posts. Oper Dent 2002 27 : 455 461.
    • (2002) Oper Dent , vol.27 , pp. 455-461
    • Edelhoff, D.1    Sorensen, J.A.2
  • 7
    • 27244457971 scopus 로고    scopus 로고
    • All-ceramic full-coverage restorations: Concepts and guidelines for material selection
    • quiz 258.
    • Raigrodski AJ. All-ceramic full-coverage restorations: concepts and guidelines for material selection. Pract Proced Aesthet Dent 2005 17 : 249 256 quiz 258.
    • (2005) Pract Proced Aesthet Dent , vol.17 , pp. 249-256
    • Raigrodski, A.J.1
  • 9
    • 0032015941 scopus 로고    scopus 로고
    • In-Ceram fixed partial dentures: Three-year clinical trial results
    • Sorensen JA, Kang SK, Torres TJ, Knode H. In-Ceram fixed partial dentures: three-year clinical trial results. J Calif Dent Assoc 1998 26 : 207 214.
    • (1998) J Calif Dent Assoc , vol.26 , pp. 207-214
    • Sorensen, J.A.1    Kang, S.K.2    Torres, T.J.3    Knode, H.4
  • 12
    • 0035351260 scopus 로고    scopus 로고
    • Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: A laboratory study
    • Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont 2001 14 : 231 238.
    • (2001) Int J Prosthodont , vol.14 , pp. 231-238
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3    Augthun, M.4    Spiekermann, H.5
  • 13
    • 33747062117 scopus 로고    scopus 로고
    • Fracture strength of two oxide ceramic crown systems after cyclic pre-loading and thermocycling
    • Vult von Steyern P, Ebbesson S, Holmgren J, Haag P, Nilner K. Fracture strength of two oxide ceramic crown systems after cyclic pre-loading and thermocycling. J Oral Rehabil 2006 33 : 682 689.
    • (2006) J Oral Rehabil , vol.33 , pp. 682-689
    • Vult Von Steyern, P.1    Ebbesson, S.2    Holmgren, J.3    Haag, P.4    Nilner, K.5
  • 14
    • 29644436765 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures. Part I: In vitro studies
    • Raigrodski AJ, Chiche GJ. All-ceramic fixed partial dentures. Part I: in vitro studies. J Esthet Restor Dent 2002 14 : 188 191.
    • (2002) J Esthet Restor Dent , vol.14 , pp. 188-191
    • Raigrodski, A.J.1    Chiche, G.J.2
  • 16
    • 0034264517 scopus 로고    scopus 로고
    • Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics
    • Tinschert J, Zwez D, Marx R, Anusavice KJ. Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics. J Dent 2000 28 : 529 535.
    • (2000) J Dent , vol.28 , pp. 529-535
    • Tinschert, J.1    Zwez, D.2    Marx, R.3    Anusavice, K.J.4
  • 17
    • 0037812257 scopus 로고    scopus 로고
    • A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs
    • Olsson KG, Furst B, Andersson B, Carlsson GE. A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs. Int J Prosthodont 2003 16 : 150 156.
    • (2003) Int J Prosthodont , vol.16 , pp. 150-156
    • Olsson, K.G.1    Furst, B.2    Andersson, B.3    Carlsson, G.E.4
  • 18
    • 0035408488 scopus 로고    scopus 로고
    • Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs
    • Vult von Steyern P, Jonsson O, Nilner K. Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont 2001 14 : 379 384.
    • (2001) Int J Prosthodont , vol.14 , pp. 379-384
    • Vult Von Steyern, P.1    Jonsson, O.2    Nilner, K.3
  • 20
    • 34247491685 scopus 로고    scopus 로고
    • Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks
    • Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci 2007 115 : 161 166.
    • (2007) Eur J Oral Sci , vol.115 , pp. 161-166
    • Kohorst, P.1    Herzog, T.J.2    Borchers, L.3    Stiesch-Scholz, M.4
  • 21
    • 33749161541 scopus 로고    scopus 로고
    • Fracture strength of artificially aged 3-unit adhesive fixed partial dentures made of fiber-reinforced composites and ceramics: An in vitro study
    • Kolbeck C, Rosentritt M, Handel G. Fracture strength of artificially aged 3-unit adhesive fixed partial dentures made of fiber-reinforced composites and ceramics: an in vitro study. Quintessence Int 2006 37 : 731 735.
    • (2006) Quintessence Int , vol.37 , pp. 731-735
    • Kolbeck, C.1    Rosentritt, M.2    Handel, G.3
  • 22
    • 31544461558 scopus 로고    scopus 로고
    • Effect of incomplete crown ferrules on load capacity of endodontically treated maxillary incisors restored with fiber posts, composite build-ups, and all-ceramic crowns: An in vitro evaluation after chewing simulation
    • Naumann M, Preuss A, Rosentritt M. Effect of incomplete crown ferrules on load capacity of endodontically treated maxillary incisors restored with fiber posts, composite build-ups, and all-ceramic crowns: an in vitro evaluation after chewing simulation. Acta Odontol Scand 2006 64 : 31 36.
    • (2006) Acta Odontol Scand , vol.64 , pp. 31-36
    • Naumann, M.1    Preuss, A.2    Rosentritt, M.3
  • 23
    • 33751088329 scopus 로고    scopus 로고
    • The effect of alveolar bone loss on the load capability of restored endodontically treated teeth: A comparative in vitro study
    • Naumann M, Rosentritt M, Preuss A, Dietrich T. The effect of alveolar bone loss on the load capability of restored endodontically treated teeth: a comparative in vitro study. J Dent 2006 34 : 790 795.
    • (2006) J Dent , vol.34 , pp. 790-795
    • Naumann, M.1    Rosentritt, M.2    Preuss, A.3    Dietrich, T.4
  • 24
    • 30344459124 scopus 로고    scopus 로고
    • Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures
    • Rosentritt M, Behr M, Gebhard R, Handel G. Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater 2006 22 : 176 182.
    • (2006) Dent Mater , vol.22 , pp. 176-182
    • Rosentritt, M.1    Behr, M.2    Gebhard, R.3    Handel, G.4
  • 25
    • 33644849619 scopus 로고    scopus 로고
    • In vitro fracture resistance of four-unit fibre-reinforced composite fixed partial dentures
    • Stiesch-Scholz M, Schulz K, Borchers L. In vitro fracture resistance of four-unit fibre-reinforced composite fixed partial dentures. Dent Mater 2006 22 : 374 381.
    • (2006) Dent Mater , vol.22 , pp. 374-381
    • Stiesch-Scholz, M.1    Schulz, K.2    Borchers, L.3
  • 26
    • 0028511896 scopus 로고
    • In vitro fracture behavior of ceramic and metal-ceramic restorations
    • Smith TB, Kelly JR, Tesk JA. In vitro fracture behavior of ceramic and metal-ceramic restorations. J Prosthodont 1994 3 : 138 144.
    • (1994) J Prosthodont , vol.3 , pp. 138-144
    • Smith, T.B.1    Kelly, J.R.2    Tesk, J.A.3
  • 27
    • 29144487947 scopus 로고    scopus 로고
    • Load-to-fracture value of different all-ceramic crown systems
    • Snyder MD, Hogg KD. Load-to-fracture value of different all-ceramic crown systems. J Contemp Dent Pract 2005 6 : 54 63.
    • (2005) J Contemp Dent Pract , vol.6 , pp. 54-63
    • Snyder, M.D.1    Hogg, K.D.2
  • 28
    • 16344387546 scopus 로고    scopus 로고
    • Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing
    • Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater 2005 21 : 476 482.
    • (2005) Dent Mater , vol.21 , pp. 476-482
    • Sundh, A.1    Molin, M.2    Sjogren, G.3
  • 29
    • 0027655860 scopus 로고
    • The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli
    • Scherrer SS, de Rijk WG. The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli. Int J Prosthodont 1993 6 : 462 467.
    • (1993) Int J Prosthodont , vol.6 , pp. 462-467
    • Scherrer, S.S.1    De Rijk, W.G.2
  • 30
    • 14844364021 scopus 로고    scopus 로고
    • All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. a 2-year clinical study
    • Vult von Steyern P, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 2005 32 : 180 187.
    • (2005) J Oral Rehabil , vol.32 , pp. 180-187
    • Vult Von Steyern, P.1    Carlson, P.2    Nilner, K.3
  • 31
    • 0032013518 scopus 로고    scopus 로고
    • Relevance of the finite element method to optimize fixed partial denture design. Part I. Influence of the size of the connector on the magnitude of strain
    • Augereau D, Pierrisnard L, Barquins M. Relevance of the finite element method to optimize fixed partial denture design. Part I. Influence of the size of the connector on the magnitude of strain. Clin Oral Investig 1998 2 : 36 39.
    • (1998) Clin Oral Investig , vol.2 , pp. 36-39
    • Augereau, D.1    Pierrisnard, L.2    Barquins, M.3
  • 32
    • 0037364513 scopus 로고    scopus 로고
    • Lifetime prediction of all-ceramic bridges by computational methods
    • Fischer H, Weber M, Marx R. Lifetime prediction of all-ceramic bridges by computational methods. J Dent Res 2003 82 : 238 242.
    • (2003) J Dent Res , vol.82 , pp. 238-242
    • Fischer, H.1    Weber, M.2    Marx, R.3
  • 33
    • 33847359597 scopus 로고    scopus 로고
    • Three-dimensional finite element analyses of all-ceramic posterior fixed partial dentures with different designs
    • Molin M, Onesti M, Petersson T, Derand T. Three-dimensional finite element analyses of all-ceramic posterior fixed partial dentures with different designs. Int J Prosthodont 2007 20 : 89 91.
    • (2007) Int J Prosthodont , vol.20 , pp. 89-91
    • Molin, M.1    Onesti, M.2    Petersson, T.3    Derand, T.4
  • 34
    • 0029318343 scopus 로고
    • Failure of all-ceramic fixed partial dentures in vitro and in vivo: Analysis and modeling
    • Kelly JR, Tesk JA, Sorensen JA. Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling. J Dent Res 1995 74 : 1253 1258.
    • (1995) J Dent Res , vol.74 , pp. 1253-1258
    • Kelly, J.R.1    Tesk, J.A.2    Sorensen, J.A.3
  • 35
    • 33745850811 scopus 로고    scopus 로고
    • How to qualify and validate wear simulation devices and methods
    • Heintze SD. How to qualify and validate wear simulation devices and methods. Dent Mater 2006 22 : 712 734.
    • (2006) Dent Mater , vol.22 , pp. 712-734
    • Heintze, S.D.1
  • 36
    • 2942547986 scopus 로고    scopus 로고
    • Fracture resistance of three all-ceramic restorative systems for posterior applications
    • Pallis K, Griggs JA, Woody RD, Guillen GE, Miller AW. Fracture resistance of three all-ceramic restorative systems for posterior applications. J Prosthet Dent 2004 91 : 561 569.
    • (2004) J Prosthet Dent , vol.91 , pp. 561-569
    • Pallis, K.1    Griggs, J.A.2    Woody, R.D.3    Guillen, G.E.4    Miller, A.W.5
  • 37
    • 33646531223 scopus 로고    scopus 로고
    • The influence of simulated masticatory loading regimes on the bi-axial flexure strength and reliability of a Y-TZP dental ceramic
    • Curtis AR, Wright AJ, Fleming GJ. The influence of simulated masticatory loading regimes on the bi-axial flexure strength and reliability of a Y-TZP dental ceramic. J Dent 2006 34 : 317 325.
    • (2006) J Dent , vol.34 , pp. 317-325
    • Curtis, A.R.1    Wright, A.J.2    Fleming, G.J.3
  • 38
    • 0036518474 scopus 로고    scopus 로고
    • Flexural strength of In-Ceram alumina and In-Ceram zirconia core materials
    • Chong KH, Chai J, Takahashi Y, Wozniak W. Flexural strength of In-Ceram alumina and In-Ceram zirconia core materials. Int J Prosthodont 2002 15 : 183 188.
    • (2002) Int J Prosthodont , vol.15 , pp. 183-188
    • Chong, K.H.1    Chai, J.2    Takahashi, Y.3    Wozniak, W.4
  • 39
    • 0035348103 scopus 로고    scopus 로고
    • Flexural strength of Cerec 2 machined and jointed InCeram-Alumina and InCeram-Zirconia bars
    • Apholt W, Bindl A, Luthy H, Mormann WH. Flexural strength of Cerec 2 machined and jointed InCeram-Alumina and InCeram-Zirconia bars. Dent Mater 2001 17 : 260 267.
    • (2001) Dent Mater , vol.17 , pp. 260-267
    • Apholt, W.1    Bindl, A.2    Luthy, H.3    Mormann, W.H.4
  • 40
    • 0141924649 scopus 로고    scopus 로고
    • Probability of failure of veneered glass fiber-reinforced composites and glass-infiltrated alumina with or without zirconia reinforcement
    • Chong KH, Chai J. Probability of failure of veneered glass fiber-reinforced composites and glass-infiltrated alumina with or without zirconia reinforcement. Int J Prosthodont 2003 16 : 487 492.
    • (2003) Int J Prosthodont , vol.16 , pp. 487-492
    • Chong, K.H.1    Chai, J.2
  • 42
    • 0025492382 scopus 로고
    • Fracture surface analysis of dental ceramics: Clinically failed restorations
    • Kelly JR, Giordano R, Pober R, Cima MJ. Fracture surface analysis of dental ceramics: clinically failed restorations. Int J Prosthodont 1990 3 : 430 440.
    • (1990) Int J Prosthodont , vol.3 , pp. 430-440
    • Kelly, J.R.1    Giordano, R.2    Pober, R.3    Cima, M.J.4
  • 43
    • 0141973963 scopus 로고
    • Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen. [Maximal biteforce, a factor in designing dental constructions]
    • Körber K, Ludwig K. Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen. [Maximal biteforce, a factor in designing dental constructions]. Dent Lab 1983 31 : 55 60.
    • (1983) Dent Lab , vol.31 , pp. 55-60
    • Körber, K.1    Ludwig, K.2
  • 45
    • 33749677224 scopus 로고    scopus 로고
    • The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
    • Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, Mercante DE. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 2006 96 : 237 244.
    • (2006) J Prosthet Dent , vol.96 , pp. 237-244
    • Raigrodski, A.J.1    Chiche, G.J.2    Potiket, N.3    Hochstedler, J.L.4    Mohamed, S.E.5    Billiot, S.6    Mercante, D.E.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.