-
1
-
-
10244223555
-
Electrode systems for continuous monitoring in cardiovascular surgery
-
Clark L.C., Lyons C. Electrode systems for continuous monitoring in cardiovascular surgery. Ann N Y Acad Sci 1962, 102:29-45.
-
(1962)
Ann N Y Acad Sci
, vol.102
, pp. 29-45
-
-
Clark, L.C.1
Lyons, C.2
-
2
-
-
84857405775
-
Review of glucose oxidases and glucose dehydrogenases: a bird's eye view of glucose sensing enzymes
-
Ferri S., Kojima K., Sode K. Review of glucose oxidases and glucose dehydrogenases: a bird's eye view of glucose sensing enzymes. J Diabetes Sci Technol 2011, 5:1068-1076.
-
(2011)
J Diabetes Sci Technol
, vol.5
, pp. 1068-1076
-
-
Ferri, S.1
Kojima, K.2
Sode, K.3
-
4
-
-
0034844040
-
Glucose biosensors: 40years of advances and challenges
-
Wang J. Glucose biosensors: 40years of advances and challenges. Electroanalysis 2001, 13:983-988.
-
(2001)
Electroanalysis
, vol.13
, pp. 983-988
-
-
Wang, J.1
-
5
-
-
0035023293
-
Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing
-
Tang Z., Louie R.F., Lee J.H., Lee D.M., Miller E.E., Kost G.J. Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing. Crit Care Med 2001, 29:1062-1070.
-
(2001)
Crit Care Med
, vol.29
, pp. 1062-1070
-
-
Tang, Z.1
Louie, R.F.2
Lee, J.H.3
Lee, D.M.4
Miller, E.E.5
Kost, G.J.6
-
6
-
-
43549095197
-
Glucose oxidase: natural occurrence, function, properties and industrial applications
-
Wong C.M., Wong K.H., Chen X.D. Glucose oxidase: natural occurrence, function, properties and industrial applications. Appl Microbiol Biotechnol 2008, 78:927-938.
-
(2008)
Appl Microbiol Biotechnol
, vol.78
, pp. 927-938
-
-
Wong, C.M.1
Wong, K.H.2
Chen, X.D.3
-
7
-
-
84858706476
-
Characterization of different FAD-dependent glucose dehydrogenases for possible use in glucose-based biosensors and biofuel cells
-
Zafar M.N., Beden N., Leech D., Sygmund C., Ludwig R., Gorton L. Characterization of different FAD-dependent glucose dehydrogenases for possible use in glucose-based biosensors and biofuel cells. Anal Bioanal Chem 2012, 402:2069-2077.
-
(2012)
Anal Bioanal Chem
, vol.402
, pp. 2069-2077
-
-
Zafar, M.N.1
Beden, N.2
Leech, D.3
Sygmund, C.4
Ludwig, R.5
Gorton, L.6
-
9
-
-
52449111730
-
A disposable electrochemical glucose sensor using catalytic subunit of novel thermostable glucose dehydrogenase
-
Yamaoka H., Sode K. A disposable electrochemical glucose sensor using catalytic subunit of novel thermostable glucose dehydrogenase. Open Biotechnol J 2007, 1:26-30.
-
(2007)
Open Biotechnol J
, vol.1
, pp. 26-30
-
-
Yamaoka, H.1
Sode, K.2
-
10
-
-
70349495829
-
Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview. Peritoneal dialysis international
-
Flore K.M., Delanghe J.R. Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview. Peritoneal dialysis international. J Int Soc Perit Dial 2009, 29:377-383.
-
(2009)
J Int Soc Perit Dial
, vol.29
, pp. 377-383
-
-
Flore, K.M.1
Delanghe, J.R.2
-
11
-
-
77953072186
-
Review of adverse events associated with false glucose readings measured by GDH-PQQ-based glucose test strips in the presence of interfering sugars
-
Frias J.P., Lim C.G., Ellison J.M., Montandon C.M. Review of adverse events associated with false glucose readings measured by GDH-PQQ-based glucose test strips in the presence of interfering sugars. Diabetes Care 2010, 33:728-729.
-
(2010)
Diabetes Care
, vol.33
, pp. 728-729
-
-
Frias, J.P.1
Lim, C.G.2
Ellison, J.M.3
Montandon, C.M.4
-
12
-
-
84896128586
-
FDA Public Health Notification: potentially fatal errors with GDH-PQQ glucose monitoring technology
-
FDA
-
FDA FDA Public Health Notification: potentially fatal errors with GDH-PQQ glucose monitoring technology. US Food Drug Adm 2009, http://www.fda.gov/medicaldevices/safety/alertsandnotices/publichealthnotifications/ucm176992.htm.
-
(2009)
US Food Drug Adm
-
-
-
13
-
-
2042548037
-
Engineering PQQ glucose dehydrogenase with improved substrate specificity. Site-directed mutagenesis studies on the active center of PQQ glucose dehydrogenase
-
Igarashi S., Hirokawa T., Sode K. Engineering PQQ glucose dehydrogenase with improved substrate specificity. Site-directed mutagenesis studies on the active center of PQQ glucose dehydrogenase. Biomol Eng 2004, 21:81-89.
-
(2004)
Biomol Eng
, vol.21
, pp. 81-89
-
-
Igarashi, S.1
Hirokawa, T.2
Sode, K.3
-
14
-
-
0033517714
-
Construction and characterization of mutant water-soluble PQQ glucose dehydrogenases with altered K(m) values-site-directed mutagenesis studies on the putative active site
-
Igarashi S., Ohtera T., Yoshida H., Witarto A.B., Sode K. Construction and characterization of mutant water-soluble PQQ glucose dehydrogenases with altered K(m) values-site-directed mutagenesis studies on the putative active site. Biochem Biophys Res Commun 1999, 264:820-824.
-
(1999)
Biochem Biophys Res Commun
, vol.264
, pp. 820-824
-
-
Igarashi, S.1
Ohtera, T.2
Yoshida, H.3
Witarto, A.B.4
Sode, K.5
-
15
-
-
33645227125
-
Novel FAD-dependent glucose dehydrogenase for a dioxygen-insensitive glucose biosensor
-
Tsujimura S., Kojima S., Kano K., et al. Novel FAD-dependent glucose dehydrogenase for a dioxygen-insensitive glucose biosensor. Biosci Biotechnol Biochem 2006, 70:654-659.
-
(2006)
Biosci Biotechnol Biochem
, vol.70
, pp. 654-659
-
-
Tsujimura, S.1
Kojima, S.2
Kano, K.3
-
16
-
-
77249122160
-
System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197
-
Freckmann G., Baumstark A., Jendrike N., et al. System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197. Diabetes Technol Ther 2010, 12:221-231.
-
(2010)
Diabetes Technol Ther
, vol.12
, pp. 221-231
-
-
Freckmann, G.1
Baumstark, A.2
Jendrike, N.3
-
17
-
-
84875805117
-
System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197
-
Freckmann G., Schmid C., Baumstark A., Pleus S., Link M., Haug C. System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197. J Diabetes Sci Technol 2012, 6:1060-1075.
-
(2012)
J Diabetes Sci Technol
, vol.6
, pp. 1060-1075
-
-
Freckmann, G.1
Schmid, C.2
Baumstark, A.3
Pleus, S.4
Link, M.5
Haug, C.6
-
18
-
-
84875803673
-
Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197
-
Baumstark A., Pleus S., Schmid C., Link M., Haug C., Freckmann G. Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197. J Diabetes Sci Technol 2012, 6:1076-1086.
-
(2012)
J Diabetes Sci Technol
, vol.6
, pp. 1076-1086
-
-
Baumstark, A.1
Pleus, S.2
Schmid, C.3
Link, M.4
Haug, C.5
Freckmann, G.6
-
19
-
-
60649086908
-
Assessing the quality of Bionime self-monitoring blood glucose system Rightest GM110: a critical evaluation of interference and ambient circumstances
-
Hsu C.T., Hsiao H.C., Lee M.S., et al. Assessing the quality of Bionime self-monitoring blood glucose system Rightest GM110: a critical evaluation of interference and ambient circumstances. Clin Chim Acta Int J Clin Chem 2009, 402:119-123.
-
(2009)
Clin Chim Acta Int J Clin Chem
, vol.402
, pp. 119-123
-
-
Hsu, C.T.1
Hsiao, H.C.2
Lee, M.S.3
-
20
-
-
79955557642
-
Accuracy and precision evaluation of seven self-monitoring blood glucose systems
-
Kuo C.Y., Hsu C.T., Ho C.S., Su T.E., Wu M.H., Wang C.J. Accuracy and precision evaluation of seven self-monitoring blood glucose systems. Diabetes Technol Ther 2011, 13:596-600.
-
(2011)
Diabetes Technol Ther
, vol.13
, pp. 596-600
-
-
Kuo, C.Y.1
Hsu, C.T.2
Ho, C.S.3
Su, T.E.4
Wu, M.H.5
Wang, C.J.6
-
22
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
23
-
-
84896132269
-
Points to consider for portable blood glucose monitoring devices intended for bedside use in the neonate nursery
-
FDA
-
FDA Points to consider for portable blood glucose monitoring devices intended for bedside use in the neonate nursery. US Food Drug Adm 1996, http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/UCM094125.pdf.
-
(1996)
US Food Drug Adm
-
-
-
24
-
-
34447137321
-
Glucose measurement: confounding issues in setting targets for inpatient management: response to Dungan et al
-
Mahoney J., Ellison J. Glucose measurement: confounding issues in setting targets for inpatient management: response to Dungan et al. Diabetes Care 2007, 30:e71.
-
(2007)
Diabetes Care
, vol.30
-
-
Mahoney, J.1
Ellison, J.2
-
25
-
-
38949097440
-
Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters
-
Karon B.S., Griesmann L., Scott R., et al. Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters. Diabetes Technol Ther 2008, 10:111-120.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 111-120
-
-
Karon, B.S.1
Griesmann, L.2
Scott, R.3
-
26
-
-
0033849382
-
Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing
-
Tang Z., Lee J.H., Louie R.F., Kost G.J. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch Pathol Lab Med 2000, 124:1135-1140.
-
(2000)
Arch Pathol Lab Med
, vol.124
, pp. 1135-1140
-
-
Tang, Z.1
Lee, J.H.2
Louie, R.F.3
Kost, G.J.4
-
27
-
-
0031761237
-
Positive interference of icodextrin metabolites in some enzymatic glucose methods
-
Janssen W., Harff G., Caers M., Schellekens A. Positive interference of icodextrin metabolites in some enzymatic glucose methods. Clin Chem 1998, 44:2379-2380.
-
(1998)
Clin Chem
, vol.44
, pp. 2379-2380
-
-
Janssen, W.1
Harff, G.2
Caers, M.3
Schellekens, A.4
-
28
-
-
19944365525
-
Screening guidelines for newborns at risk for low blood glucose
-
Aziz K., Dancey P. Screening guidelines for newborns at risk for low blood glucose. J Paediatr Child Health 2004, 9:723-729.
-
(2004)
J Paediatr Child Health
, vol.9
, pp. 723-729
-
-
Aziz, K.1
Dancey, P.2
-
29
-
-
79952203402
-
Postnatal glucose homeostasis in late-preterm and term infants
-
Adamkin D.H. Postnatal glucose homeostasis in late-preterm and term infants. Pediatrics 2011, 127:575-579.
-
(2011)
Pediatrics
, vol.127
, pp. 575-579
-
-
Adamkin, D.H.1
-
30
-
-
21444450978
-
The investigation and management of neonatal hypoglycaemia
-
Deshpande S., Ward Platt M. The investigation and management of neonatal hypoglycaemia. Semin Fetal Neonatal Med 2005, 10:351-361.
-
(2005)
Semin Fetal Neonatal Med
, vol.10
, pp. 351-361
-
-
Deshpande, S.1
Ward, P.M.2
-
31
-
-
0030662966
-
Neonatal hypoglycemia, Part I: background and definition
-
Halamek L.P., Benaron D.A., Stevenson D.K. Neonatal hypoglycemia, Part I: background and definition. Clin Pediatr 1997, 36:675-680.
-
(1997)
Clin Pediatr
, vol.36
, pp. 675-680
-
-
Halamek, L.P.1
Benaron, D.A.2
Stevenson, D.K.3
-
32
-
-
34249902075
-
Assessing the quality of glucose monitor studies: a critical evaluation of published reports
-
Mahoney J., Ellison J. Assessing the quality of glucose monitor studies: a critical evaluation of published reports. Clin Chem 2007, 53:1122-1128.
-
(2007)
Clin Chem
, vol.53
, pp. 1122-1128
-
-
Mahoney, J.1
Ellison, J.2
-
33
-
-
60249099082
-
Consensus report of the coalition for clinical research-self-monitoring of blood glucose
-
Klonoff D.C., Bergenstal R., Blonde L., et al. Consensus report of the coalition for clinical research-self-monitoring of blood glucose. J Diabetes Sci Technol 2008, 2:1030-1053.
-
(2008)
J Diabetes Sci Technol
, vol.2
, pp. 1030-1053
-
-
Klonoff, D.C.1
Bergenstal, R.2
Blonde, L.3
-
34
-
-
84875203570
-
Assessing the quality of publications evaluating the accuracy of blood glucose monitoring systems
-
Thorpe G.H. Assessing the quality of publications evaluating the accuracy of blood glucose monitoring systems. Diabetes Technol Ther 2013, 15:253-259.
-
(2013)
Diabetes Technol Ther
, vol.15
, pp. 253-259
-
-
Thorpe, G.H.1
-
35
-
-
20544458073
-
What is accuracy and how close must the agreement be?
-
Nichols J.H. What is accuracy and how close must the agreement be?. Diabetes Technol Ther 2005, 7:558-562.
-
(2005)
Diabetes Technol Ther
, vol.7
, pp. 558-562
-
-
Nichols, J.H.1
-
36
-
-
84865146825
-
Accuracy in blood glucose measurement: what will a tightening of requirements yield?
-
Heinemann L., Lodwig V., Freckmann G. Accuracy in blood glucose measurement: what will a tightening of requirements yield?. J Diabetes Sci Technol 2012, 6:435-443.
-
(2012)
J Diabetes Sci Technol
, vol.6
, pp. 435-443
-
-
Heinemann, L.1
Lodwig, V.2
Freckmann, G.3
-
37
-
-
36348960172
-
Assessing glucose monitor performance-a standardized approach
-
Mahoney J.J., Ellison J.M. Assessing glucose monitor performance-a standardized approach. Diabetes Technol Ther 2007, 9:545-552.
-
(2007)
Diabetes Technol Ther
, vol.9
, pp. 545-552
-
-
Mahoney, J.J.1
Ellison, J.M.2
|