Accuracy in blood glucose measurement: What will a tightening of requirements yield?

Author keywords

Accuracy; Blood glucose measurement; Self monitoring; SMBG; System accuracy

Indexed keywords

BLOOD GLUCOSE METER; BLOOD GLUCOSE MONITORING; FOOD AND DRUG ADMINISTRATION; GLUCOSE BLOOD LEVEL; HUMAN; MEASUREMENT ACCURACY; METABOLIC REGULATION; NOTE; QUALITY CONTROL; UNITED STATES; ARTICLE; BLOOD; DEVICE APPROVAL; DIABETES MELLITUS; DRUG EFFECT; EQUIPMENT DESIGN; HEALTH CARE COST; INSTRUMENTATION; LEGAL ASPECT; METABOLISM; PATIENT SAFETY; PRACTICE GUIDELINE; PREDICTIVE VALUE; REPRODUCIBILITY; STANDARD;

EID: 84865146825     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681200600232     Document Type: Note
Times cited : (18)

References (17)
  • 4
    • 1442275314 scopus 로고    scopus 로고
    • The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges
    • Klonof DC. The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges. Diabetes Care. 2004;27:834-6.
    • (2004) Diabetes Care , vol.27 , pp. 834-836
    • Klonof, D.C.1
  • 5
    • 57349106743 scopus 로고    scopus 로고
    • Standardized evaluation of nine instruments for self-monitoring of blood glucose
    • Kristensen GB, Monsen G, Skeie S, Sandberg S. Standardized evaluation of nine instruments for self-monitoring of blood glucose. Diabetes Technol Ther. 2008;10:467-77.
    • (2008) Diabetes Technol Ther , vol.10 , pp. 467-477
    • Kristensen, G.B.1    Monsen, G.2    Skeie, S.3    Sandberg, S.4
  • 6
    • 3142583462 scopus 로고    scopus 로고
    • Plasma glucose measurement with the Yellow Spring Glucose 2300 STAT and the Olympus AU640
    • DOI 10.1136/jcp.2003.013417
    • Twomey PJ. Plasma glucose measurement with the Yellow Springs Glucose 2300 STAT and the Olympus AU640. J Clin Pathol. 2004;57:752-4. (Pubitemid 38901492)
    • (2004) Journal of Clinical Pathology , vol.57 , Issue.7 , pp. 752-754
    • Twomey, P.J.1
  • 7
    • 6044271612 scopus 로고    scopus 로고
    • Measurement of insulin absorption and insulin action
    • DOI 10.1089/dia.2004.6.698
    • Heinemann L, Anderson JH. Measurement of insulin absorption and insulin action. Diabetes Technol Therap. 2004;6:698-718. (Pubitemid 39383074)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.5 , pp. 698-718
    • Heinemann, L.1    Anderson Jr., J.H.2
  • 9
    • 78349287412 scopus 로고    scopus 로고
    • The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors
    • Klonof DC. The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors. J Diabetes Sci Technol. 2010;4:499-504.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 499-504
    • Klonof, D.C.1
  • 10
    • 79952199087 scopus 로고    scopus 로고
    • We need tighter regulatory standards for blood glucose monitoring, but they should be for accuracy disclosure
    • Ginsberg BH. We need tighter regulatory standards for blood glucose monitoring, but they should be for accuracy disclosure. J Diabetes Sci Technol. 2010;4:1265-8.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 1265-1268
    • Ginsberg, B.H.1
  • 12
    • 77954230653 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose with a focus on analytical quality: An overview
    • Kristensen GB, Sandberg S. Self-monitoring of blood glucose with a focus on analytical quality: an overview. Clin Chem Lab Med. 2010;48:963-72.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 963-972
    • Kristensen, G.B.1    Sandberg, S.2
  • 13
    • 44249090496 scopus 로고    scopus 로고
    • Parameters afecting postprandial blood glucose: Efects of blood glucose measurement errors
    • Koschinsky T, Heckermann S, Heinemann L. Parameters afecting postprandial blood glucose: efects of blood glucose measurement errors. J Diabetes Sci Technol. 2008;2:58-66.
    • (2008) J Diabetes Sci Technol , vol.2 , pp. 58-66
    • Koschinsky, T.1    Heckermann, S.2    Heinemann, L.3
  • 14
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10:622-8. (Pubitemid 17158937)
    • (1987) Diabetes Care , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 15
    • 70350209515 scopus 로고    scopus 로고
    • Factors afecting blood glucose monitoring: Sources of errors in measurement
    • Ginsberg BH. Factors afecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol. 2009;3:903-13.
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 903-913
    • Ginsberg, B.H.1
  • 16
    • 0035130886 scopus 로고    scopus 로고
    • Quality specifications for glucose meters: Assessment by simulation modeling of errors in insulin dose
    • Boyd JC, Bruns DE. Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose. Clin Chem. 2001;47:209-14. (Pubitemid 32142918)
    • (2001) Clinical Chemistry , vol.47 , Issue.2 , pp. 209-214
    • Boyd, J.C.1    Bruns, D.E.2
  • 17
    • 77953148918 scopus 로고    scopus 로고
    • Glucose meter performance criteria for tight glycemic control estimated by simulation modeling
    • Karon BS, Boyd JC, Klee GG. Glucose meter performance criteria for tight glycemic control estimated by simulation modeling. Clin Chem 2010;56:1091-7.
    • (2010) Clin Chem , vol.56 , pp. 1091-1097
    • Karon, B.S.1    Boyd, J.C.2    Klee, G.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.