메뉴 건너뛰기




Volumn 29, Issue 4, 2009, Pages 377-383

Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: An overview

Author keywords

GDH PQQ; Hyperglycemia; Icodextrin; Maltose; Point of care testing

Indexed keywords

AMYLASE; GLUCOSE; GLUCOSE DEHYDROGENASE; GLUCOSE POLYMER; ICODEXTRIN; MALTOSE; PYRROLOQUINOLINEQUINONE;

EID: 70349495829     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: 10.1177/089686080902900403     Document Type: Review
Times cited : (40)

References (52)
  • 1
    • 0036841548 scopus 로고    scopus 로고
    • A randomized controlled trial to evaluate the efficacy and safety of icodextrin in peritoneal dialysis
    • Wolfson M, Piraino B, Hamburger RJ, Morton R. A randomized controlled trial to evaluate the efficacy and safety of icodextrin in peritoneal dialysis. Am J Kidney Dis 2002; 40:1055-65.
    • (2002) Am J Kidney Dis , vol.40 , pp. 1055-1065
    • Wolfson, M.1    Piraino, B.2    Hamburger, R.J.3    Morton, R.4
  • 2
    • 0036379580 scopus 로고    scopus 로고
    • Review of clinical trial experience with icodextrin
    • Wolfson M, Ogrinc F, Mujais S. Review of clinical trial experience with icodextrin. Kidney Int Suppl 2002; 81: S46-52.
    • (2002) Kidney Int Suppl , vol.81
    • Wolfson, M.1    Ogrinc, F.2    Mujais, S.3
  • 3
    • 0035123507 scopus 로고    scopus 로고
    • Biocompatibility of new peritoneal dialysis solutions: Clinical experience
    • Garcia-Lopez E, Lindholm B, Tranaeus A. Biocompatibility of new peritoneal dialysis solutions: clinical experience. Perit Dial Int 2000; 20(Suppl 5):S48-56.
    • (2000) Perit Dial Int , vol.20 , Issue.SUPPL. 5
    • Garcia-Lopez, E.1    Lindholm, B.2    Tranaeus, A.3
  • 4
    • 4344696765 scopus 로고    scopus 로고
    • Long-term exposure to new peritoneal dialysis solutions: Effects on the peritoneal membrane
    • Mortier S, Faict D, Schalwijk CG, Lameire NH, De Vriese AS. Long-term exposure to new peritoneal dialysis solutions: effects on the peritoneal membrane. Kidney Int 2004; 66:1257-65.
    • (2004) Kidney Int , vol.66 , pp. 1257-1265
    • Mortier, S.1    Faict, D.2    Schalwijk, C.G.3    Lameire, N.H.4    De Vriese, A.S.5
  • 5
    • 0034085412 scopus 로고    scopus 로고
    • Assessment of the effectiveness, safety, and biocompatibility of icodextrin in automated peritoneal dialysis. The Dextrin in APD in Amsterdam (DIANA) Group
    • Posthuma N, ter Wee PM, Donker AJ, Oe PL, Peers EM, Verbrugh HA. Assessment of the effectiveness, safety, and biocompatibility of icodextrin in automated peritoneal dialysis. The Dextrin in APD in Amsterdam (DIANA) Group. Perit Dial Int 2000; 20(Suppl 2):S106-13.
    • (2000) Perit Dial Int , vol.20 , Issue.SUPPL. 2
    • Posthuma, N.1    ter Wee, P.M.2    Donker, A.J.3    Oe, P.L.4    Peers, E.M.5    Verbrugh, H.A.6
  • 6
    • 0027980379 scopus 로고
    • The use of glucose polymer (icodextrin) in peritoneal dialysis: An overview
    • Mistry CD, Gokal R. The use of glucose polymer (icodextrin) in peritoneal dialysis: an overview. Perit Dial Int 1994; 14(Suppl 3):S158-61.
    • (1994) Perit Dial Int , vol.14 , Issue.SUPPL. 3
    • Mistry, C.D.1    Gokal, R.2
  • 7
    • 33748428468 scopus 로고    scopus 로고
    • What is the optimal dwell time for maximizing ultrafiltration with icodextrin exchange in automated peritoneal dialysis patients?
    • Jeloka TK, Ersoy FF, Yavuz M, Sahu KM, Camsari T, Utas C, et al. What is the optimal dwell time for maximizing ultrafiltration with icodextrin exchange in automated peritoneal dialysis patients? Perit Dial Int 2006; 26:336-40.
    • (2006) Perit Dial Int , vol.26 , pp. 336-340
    • Jeloka, T.K.1    Ersoy, F.F.2    Yavuz, M.3    Sahu, K.M.4    Camsari, T.5    Utas, C.6
  • 8
    • 0036379689 scopus 로고    scopus 로고
    • Use of icodextrin in high transport ultrafiltration failure
    • Krediet R, Mujais S. Use of icodextrin in high transport ultrafiltration failure. Kidney Int Suppl 2002; 81:S53-61.
    • (2002) Kidney Int Suppl , vol.81
    • Krediet, R.1    Mujais, S.2
  • 11
    • 0141797504 scopus 로고    scopus 로고
    • Spurious hyperglycaemia and icodextrin in peritoneal dialysis fluid
    • Riley SG, Chess J, Donovan KL, Williams JD. Spurious hyperglycaemia and icodextrin in peritoneal dialysis fluid. BMJ 2003; 327:608-9.
    • (2003) BMJ , vol.327 , pp. 608-609
    • Riley, S.G.1    Chess, J.2    Donovan, K.L.3    Williams, J.D.4
  • 12
    • 0027989768 scopus 로고
    • A randomized multicenter clinical trial comparing isomolar icodextrin with hyperosmolar glucose solutions in CAPD. MIDAS Study Group. Multicenter Investigation of Icodextrin in Ambulatory Peritoneal Dialysis
    • Mistry CD, Gokal R, Peers E. A randomized multicenter clinical trial comparing isomolar icodextrin with hyperosmolar glucose solutions in CAPD. MIDAS Study Group. Multicenter Investigation of Icodextrin in Ambulatory Peritoneal Dialysis. Kidney Int 1994; 46:496-503.
    • (1994) Kidney Int , vol.46 , pp. 496-503
    • Mistry, C.D.1    Gokal, R.2    Peers, E.3
  • 13
    • 34447534484 scopus 로고    scopus 로고
    • Effects of icodextrin on glycemic and lipid profiles in diabetic patients undergoing peritoneal dialysis
    • Babazono T, Nakamoto H, Kasai K, Kuriyama S, Sugimoto T, Nakayama M, et al. Effects of icodextrin on glycemic and lipid profiles in diabetic patients undergoing peritoneal dialysis. Am J Nephrol 2007; 27:409-15.
    • (2007) Am J Nephrol , vol.27 , pp. 409-415
    • Babazono, T.1    Nakamoto, H.2    Kasai, K.3    Kuriyama, S.4    Sugimoto, T.5    Nakayama, M.6
  • 14
    • 0034896985 scopus 로고    scopus 로고
    • Effects of peritoneal dialysis with an overnight icodextrin dwell on parameters of glucose and lipid metabolism
    • Bredie SJ, Bosch FH, Demacker PN, Stalenhoef AF, van Leusen R. Effects of peritoneal dialysis with an overnight icodextrin dwell on parameters of glucose and lipid metabolism. Perit Dial Int 2001; 21:275-81.
    • (2001) Perit Dial Int , vol.21 , pp. 275-281
    • Bredie, S.J.1    Bosch, F.H.2    Demacker, P.N.3    Stalenhoef, A.F.4    van Leusen, R.5
  • 15
    • 10744222476 scopus 로고    scopus 로고
    • Icodextrin improves the fluid status of peritoneal dialysis patients: Results of a double-blind randomized controlled trial
    • Davies SJ, Woodrow G, Donovan K, Plum J, Williams P, Johansson AC, et al. Icodextrin improves the fluid status of peritoneal dialysis patients: results of a double-blind randomized controlled trial. J Am Soc Nephrol 2003; 14: 2338-44.
    • (2003) J Am Soc Nephrol , vol.14 , pp. 2338-2344
    • Davies, S.J.1    Woodrow, G.2    Donovan, K.3    Plum, J.4    Williams, P.5    Johansson, A.C.6
  • 16
    • 34248588314 scopus 로고    scopus 로고
    • Icodextrin and insulin resistance in continuous ambulatory peritoneal dialysis patients
    • Canbakan M, Sahin GM. Icodextrin and insulin resistance in continuous ambulatory peritoneal dialysis patients. Ren Fail 2007; 29:289-93.
    • (2007) Ren Fail , vol.29 , pp. 289-293
    • Canbakan, M.1    Sahin, G.M.2
  • 17
    • 33749591526 scopus 로고    scopus 로고
    • The effect of icodextrin and glucose-containing solutions on insulin resistance in CAPD patients
    • Gürsu EM, Ozdemir A, Yalinbas B, Gürsu RU, Canbakan M, Güven B, et al. The effect of icodextrin and glucose-containing solutions on insulin resistance in CAPD patients. Clin Nephrol 2006; 66:263-8.
    • (2006) Clin Nephrol , vol.66 , pp. 263-268
    • Gürsu, E.M.1    Ozdemir, A.2    Yalinbas, B.3    Gürsu, R.U.4    Canbakan, M.5    Güven, B.6
  • 18
    • 0031761237 scopus 로고    scopus 로고
    • Positive interference of icodextrin metabolites in some enzymatic glucose methods [Letter]
    • Janssen W, Harff G, Caers M, Schellekens A. Positive interference of icodextrin metabolites in some enzymatic glucose methods [Letter]. Clin Chem 1998; 44:2379-80.
    • (1998) Clin Chem , vol.44 , pp. 2379-2380
    • Janssen, W.1    Harff, G.2    Caers, M.3    Schellekens, A.4
  • 20
    • 2942676862 scopus 로고    scopus 로고
    • Glucose monitoring for diabetic patients using icodextrin
    • Wang R, Skoufos L, Martis L. Glucose monitoring for diabetic patients using icodextrin. Perit Dial Int 2004; 24: 296-7.
    • (2004) Perit Dial Int , vol.24 , pp. 296-297
    • Wang, R.1    Skoufos, L.2    Martis, L.3
  • 21
    • 0001844948 scopus 로고
    • Kinetics of icodextrin
    • Davies DS. Kinetics of icodextrin. Perit Dial Int 1994; 14(Suppl 2):S45-50.
    • (1994) Perit Dial Int , vol.14 , Issue.SUPPL. 2
    • Davies, D.S.1
  • 22
    • 16844380850 scopus 로고    scopus 로고
    • Determination of high and low molecular weight molecules of icodextrin in plasma and dialysate, using gel filtration chromatography, in peritoneal dialysis patients
    • Garcia-Lopez E, Anderstam B, Heimbürger O, Amici G, Werynski A, Lindholm B. Determination of high and low molecular weight molecules of icodextrin in plasma and dialysate, using gel filtration chromatography, in peritoneal dialysis patients. Perit Dial Int 2005; 25:181-91.
    • (2005) Perit Dial Int , vol.25 , pp. 181-191
    • Garcia-Lopez, E.1    Anderstam, B.2    Heimbürger, O.3    Amici, G.4    Werynski, A.5    Lindholm, B.6
  • 23
    • 0036200173 scopus 로고    scopus 로고
    • Efficacy and safety of a 7.5% icodextrin peritoneal dialysis solution in patients treated with automated peritoneal dialysis
    • Plum J, Gentile S, Verger C, Brunkhorst R, Bahner U, Faller B, et al. Efficacy and safety of a 7.5% icodextrin peritoneal dialysis solution in patients treated with automated peritoneal dialysis. Am J Kidney Dis 2002; 39:862-71.
    • (2002) Am J Kidney Dis , vol.39 , pp. 862-871
    • Plum, J.1    Gentile, S.2    Verger, C.3    Brunkhorst, R.4    Bahner, U.5    Faller, B.6
  • 24
    • 0022830441 scopus 로고
    • Quinoprotein glucose dehydrogenase and its application in an amperometric glucose sensor
    • D'Costa EJ, Higgins IJ, Turner APF. Quinoprotein glucose dehydrogenase and its application in an amperometric glucose sensor. Biosensors 1986; 2:71-87.
    • (1986) Biosensors , vol.2 , pp. 71-87
    • D'Costa, E.J.1    Higgins, I.J.2    Turner, A.P.F.3
  • 25
    • 0025830659 scopus 로고
    • Quinoproteins: Enzymes containing the quinonoid cofactor pyrroloquinoline quinone, topaquinone or tryptophan-tryptophan quinone
    • Duine JA. Quinoproteins: enzymes containing the quinonoid cofactor pyrroloquinoline quinone, topaquinone or tryptophan-tryptophan quinone. Eur J Biochem 1991; 200:271-84.
    • (1991) Eur J Biochem , vol.200 , pp. 271-284
    • Duine, J.A.1
  • 26
    • 34548306928 scopus 로고    scopus 로고
    • Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems
    • Schleis TG. Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems. Pharmacotherapy 2007; 27:1313-21.
    • (2007) Pharmacotherapy , vol.27 , pp. 1313-1321
    • Schleis, T.G.1
  • 28
    • 0032449162 scopus 로고    scopus 로고
    • A previously undescribed side effect of icodextrin: Overestimation of glycemia by glucose analyzer
    • Wens R, Taminne M, Devriendt J, Collart F, Broeders N, Mestrez F, et al. A previously undescribed side effect of icodextrin: overestimation of glycemia by glucose analyzer. Perit Dial Int 1998; 18:603-9.
    • (1998) Perit Dial Int , vol.18 , pp. 603-609
    • Wens, R.1    Taminne, M.2    Devriendt, J.3    Collart, F.4    Broeders, N.5    Mestrez, F.6
  • 29
    • 0035174871 scopus 로고    scopus 로고
    • Conversion of a glutamate dehydrogenase into methionine/ norleucine dehydrogenase by site-directed mutagenesis
    • Wang XG, Britton KL, Stillman TJ, Rice DW, Engel PC. Conversion of a glutamate dehydrogenase into methionine/ norleucine dehydrogenase by site-directed mutagenesis. Eur J Biochem 2001; 268:5791-9.
    • (2001) Eur J Biochem , vol.268 , pp. 5791-5799
    • Wang, X.G.1    Britton, K.L.2    Stillman, T.J.3    Rice, D.W.4    Engel, P.C.5
  • 30
    • 0345537432 scopus 로고    scopus 로고
    • Method for the colorimetric determination of an analyte with PQQ-dependent dehydrogenase
    • US Patent 5484708
    • Hoenes J, Unkrig V. Method for the colorimetric determination of an analyte with PQQ-dependent dehydrogenase. US Patent 5484708.
    • Hoenes, J.1    Unkrig, V.2
  • 31
    • 0024315265 scopus 로고
    • Quinoproteins, enzymes with pyrrolo-quinoline quinone as cofactor
    • Duine JA, Jongejan JA. Quinoproteins, enzymes with pyrrolo-quinoline quinone as cofactor. Annu Rev Biochem 1989; 58:403-26.
    • (1989) Annu Rev Biochem , vol.58 , pp. 403-426
    • Duine, J.A.1    Jongejan, J.A.2
  • 32
    • 0030478428 scopus 로고    scopus 로고
    • Olsthoorn AJ, Duine JA. Production, characterization, and reconstitution of recombinant quinoprotein glucose dehydrogenase (soluble type; EC1.1.99.17) apoenzyme of Acinetobacter calcoaceticus. Arch Biochem Biophys 1996; 336:42-8.
    • Olsthoorn AJ, Duine JA. Production, characterization, and reconstitution of recombinant quinoprotein glucose dehydrogenase (soluble type; EC1.1.99.17) apoenzyme of Acinetobacter calcoaceticus. Arch Biochem Biophys 1996; 336:42-8.
  • 33
    • 0033517714 scopus 로고    scopus 로고
    • Construction and characterization of mutant water-soluble PDD glucose dehydrogenase with altered K(m) values-site-directed mutagenesis studies on the putative active site
    • Igarashi S, Ohtera T, Yoshida H, Witarto AB, Sode K. Construction and characterization of mutant water-soluble PDD glucose dehydrogenase with altered K(m) values-site-directed mutagenesis studies on the putative active site. Biochem Biophys Res Commun 1999; 264:820-4.
    • (1999) Biochem Biophys Res Commun , vol.264 , pp. 820-824
    • Igarashi, S.1    Ohtera, T.2    Yoshida, H.3    Witarto, A.B.4    Sode, K.5
  • 34
    • 0022979007 scopus 로고    scopus 로고
    • Dokter P, Frank J, Duine JA. Purification and characterization of quinoprotein glucose dehydrogenase from Acinetobacter calcoaceticus L.M.D.79.41. Biochem J 1986; 239:163-8.
    • Dokter P, Frank J, Duine JA. Purification and characterization of quinoprotein glucose dehydrogenase from Acinetobacter calcoaceticus L.M.D.79.41. Biochem J 1986; 239:163-8.
  • 35
    • 70349521293 scopus 로고    scopus 로고
    • http://www.octapharma.com/USA/documents/ FINAL%20Maltose%20WARNING%20Letter%2019-10-5.pdf
  • 36
    • 33846947575 scopus 로고    scopus 로고
    • Icodextrin: A major problem for glucose dehydrogenase-based glucose point of care testing systems
    • Floré K, Delanghe JR. Icodextrin: a major problem for glucose dehydrogenase-based glucose point of care testing systems. Acta Clin Belg 2006; 61:351-4.
    • (2006) Acta Clin Belg , vol.61 , pp. 351-354
    • Floré, K.1    Delanghe, J.R.2
  • 37
    • 0034897096 scopus 로고    scopus 로고
    • Icodextrin degradation products in spent dialysate of CAPD patients and the rat, and its relation with dialysate osmolality
    • de Waart DR, Zweers MM, Struijk DG, Krediet RT. Icodextrin degradation products in spent dialysate of CAPD patients and the rat, and its relation with dialysate osmolality. Perit Dial Int 2001; 21:269-74.
    • (2001) Perit Dial Int , vol.21 , pp. 269-274
    • de Waart, D.R.1    Zweers, M.M.2    Struijk, D.G.3    Krediet, R.T.4
  • 38
    • 34047120691 scopus 로고    scopus 로고
    • Icodextrin still a cause for concern with blood glucose monitoring in continuous ambulatory peritoneal dialysis patients with diabetes [Letter]
    • Slim S, Griffiths MJ, Gama R. Icodextrin still a cause for concern with blood glucose monitoring in continuous ambulatory peritoneal dialysis patients with diabetes [Letter]. Ann Clin Biochem 2007; 44:196-7.
    • (2007) Ann Clin Biochem , vol.44 , pp. 196-197
    • Slim, S.1    Griffiths, M.J.2    Gama, R.3
  • 39
    • 0033656708 scopus 로고    scopus 로고
    • Polyglucose dialysis solution influences serum activity of amylase and of lipase differently
    • Grzegorzewska AE, Antczak-Jedrzejczak D, Mariak I. Polyglucose dialysis solution influences serum activity of amylase and of lipase differently. Adv Perit Dial 2000; 16: 113-18.
    • (2000) Adv Perit Dial , vol.16 , pp. 113-118
    • Grzegorzewska, A.E.1    Antczak-Jedrzejczak, D.2    Mariak, I.3
  • 40
    • 0036842103 scopus 로고    scopus 로고
    • Dialysis with icodextrin interferes with measurement of serum alpha-amylase activity
    • Schoenicke G, Grabensee B, Plum J. Dialysis with icodextrin interferes with measurement of serum alpha-amylase activity. Nephrol Dial Transplant 2002; 17:1988-92.
    • (2002) Nephrol Dial Transplant , vol.17 , pp. 1988-1992
    • Schoenicke, G.1    Grabensee, B.2    Plum, J.3
  • 41
    • 0037355887 scopus 로고    scopus 로고
    • Determination of alpha-amylase activity in serum and dialysate from patients using icodextrin-based peritoneal dialysis fluid
    • Anderstam B, Garcia-Lopez E, Heimburger O, Lindholm B. Determination of alpha-amylase activity in serum and dialysate from patients using icodextrin-based peritoneal dialysis fluid. Perit Dial Int 2003; 23:146-50.
    • (2003) Perit Dial Int , vol.23 , pp. 146-150
    • Anderstam, B.1    Garcia-Lopez, E.2    Heimburger, O.3    Lindholm, B.4
  • 42
    • 0036361712 scopus 로고    scopus 로고
    • Kinetic analysis of icodextrin interference with serum amylase assays
    • Wang R, Leesch V, Turner P, Moberly JB, Martis L. Kinetic analysis of icodextrin interference with serum amylase assays. Adv Perit Dial 2002; 18:96-9.
    • (2002) Adv Perit Dial , vol.18 , pp. 96-99
    • Wang, R.1    Leesch, V.2    Turner, P.3    Moberly, J.B.4    Martis, L.5
  • 43
    • 0027263424 scopus 로고
    • Single daily overnight (12-h dwell) use of 7.5% glucose polymer (Mw 18700; Mn 7300) +0.35% glucose solution: A 3-month study
    • Mistry CD, Gokal R. Single daily overnight (12-h dwell) use of 7.5% glucose polymer (Mw 18700; Mn 7300) +0.35% glucose solution: a 3-month study. Nephrol Dial Transplant 1993; 8:443-7.
    • (1993) Nephrol Dial Transplant , vol.8 , pp. 443-447
    • Mistry, C.D.1    Gokal, R.2
  • 44
    • 48949117513 scopus 로고    scopus 로고
    • Rate of synthetic oligosaccharide degradation as a novel measure of amylase activity in peritoneal dialysis patients
    • Garcia-Lopez E, Werynski A, Heimbürger O, Filho JC, Lindholm B, Anderstam B. Rate of synthetic oligosaccharide degradation as a novel measure of amylase activity in peritoneal dialysis patients. Perit Dial Int 2008; 28: 296-304.
    • (2008) Perit Dial Int , vol.28 , pp. 296-304
    • Garcia-Lopez, E.1    Werynski, A.2    Heimbürger, O.3    Filho, J.C.4    Lindholm, B.5    Anderstam, B.6
  • 46
    • 70349538275 scopus 로고    scopus 로고
    • Effect of icodextrin on laboratory measurements
    • Available at
    • Lage C. Effect of icodextrin on laboratory measurements. PDServe.Connection 2004; 8(2):1-3. Available at: http://www.pdserve.com/pdserve/pdserve.nsf/Content/PDServe+Connection
    • (2004) PDServe.Connection , vol.8 , Issue.2 , pp. 1-3
    • Lage, C.1
  • 47
    • 70349518193 scopus 로고    scopus 로고
    • Accu-Chek Comfort Curve Test Strips [package insert, Indianapolis, IN: Roche Diagnostics; 2004
    • Accu-Chek Comfort Curve Test Strips [package insert]. Indianapolis, IN: Roche Diagnostics; 2004.
  • 49
    • 0034851188 scopus 로고    scopus 로고
    • Important causes of hypoglycaemia in patients with diabetes on peritoneal dialysis
    • Mehmet S, Quan G, Thomas S, Goldsmith D. Important causes of hypoglycaemia in patients with diabetes on peritoneal dialysis. Diabet Med 2001; 18:679-82.
    • (2001) Diabet Med , vol.18 , pp. 679-682
    • Mehmet, S.1    Quan, G.2    Thomas, S.3    Goldsmith, D.4
  • 50
    • 4444369757 scopus 로고    scopus 로고
    • Hypoglycaemic coma in a diabetic patient on peritoneal dialysis due to interference of icodextrin metabolites with capillary blood glucose measurements [Letter]
    • Disse E, Thivolet C. Hypoglycaemic coma in a diabetic patient on peritoneal dialysis due to interference of icodextrin metabolites with capillary blood glucose measurements [Letter]. Diabetes Care 2004; 27:2279.
    • (2004) Diabetes Care , vol.27 , pp. 2279
    • Disse, E.1    Thivolet, C.2
  • 51
    • 18244365107 scopus 로고    scopus 로고
    • Interference between Extraneal peritoneal dialysis and the Accu-Chek blood glucose monitor [Letter]
    • Hoftman N. Interference between Extraneal peritoneal dialysis and the Accu-Chek blood glucose monitor [Letter]. Anesthesiology 2005; 102:871.
    • (2005) Anesthesiology , vol.102 , pp. 871
    • Hoftman, N.1
  • 52
    • 34249059612 scopus 로고    scopus 로고
    • Improved specificity of reagentless amperometric PQQ-sGDH glucose biosensors by using indirectly heated electrodes
    • Lau C, Borgmann S, Maciejewska M, Ngounou B, Gründler P, Schuhmann W. Improved specificity of reagentless amperometric PQQ-sGDH glucose biosensors by using indirectly heated electrodes. Biosens Bioelectron 2007; 22: 3014-20.
    • (2007) Biosens Bioelectron , vol.22 , pp. 3014-3020
    • Lau, C.1    Borgmann, S.2    Maciejewska, M.3    Ngounou, B.4    Gründler, P.5    Schuhmann, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.