메뉴 건너뛰기




Volumn 13, Issue 1, 2013, Pages 334-366

Adaptive optics technology for high-resolution retinal imaging

Author keywords

Adaptive optical systems; Biomedical imaging techniques; Eye; Optical sensors

Indexed keywords

ADAPTIVE OPTICAL SYSTEMS; ADAPTIVE OPTICS TECHNOLOGY; AGE-RELATED MACULAR DEGENERATION; BIOMEDICAL IMAGING; DIABETIC RETINOPATHY; DIRECT VISUALIZATION; EYE; PATHOLOGICAL CHANGES;

EID: 84872787059     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s130100334     Document Type: Review
Times cited : (91)

References (172)
  • 1
    • 75949106260 scopus 로고    scopus 로고
    • Wave aberration of human eyes and new descriptors of image optical quality of the eye
    • Lombardo, M.; Lombardo, G. Wave aberration of human eyes and new descriptors of image optical quality of the eye. J. Cataract Refract. Surg. 2010, 36, 313-331.
    • (2010) J. Cataract Refract. Surg. , vol.36 , pp. 313-331
    • Lombardo, M.1    Lombardo, G.2
  • 2
    • 0036884049 scopus 로고    scopus 로고
    • Statistical variation of aberration structure and image quality in a normal population of healthy eyes
    • Thibos, L.N.; Hong, X.; Bradley, A.; Cheng, X. Statistical variation of aberration structure and image quality in a normal population of healthy eyes. JOSA A 2002, 19, 2329-2348.
    • (2002) JOSA A , vol.19 , pp. 2329-2348
    • Thibos, L.N.1    Hong, X.2    Bradley, A.3    Cheng, X.4
  • 3
    • 1542754974 scopus 로고    scopus 로고
    • The prospects for super-acuity: Limits to visual performance after correction of monochromatic ocular aberration
    • Charman, W.N.; Chateau, N. The prospects for super-acuity: Limits to visual performance after correction of monochromatic ocular aberration. Ophthalmic Physl. Opt. 2003, 23, 479-493.
    • (2003) Ophthalmic Physl. Opt. , vol.23 , pp. 479-493
    • Charman, W.N.1    Chateau, N.2
  • 4
    • 0036362468 scopus 로고    scopus 로고
    • Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes
    • Guirao, A.; Porter, J.; Williams, D.R.; Cox, I.G. Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes. JOSA A 2002, 19, 1-9.
    • (2002) JOSA A , vol.19 , pp. 1-9
    • Guirao, A.1    Porter, J.2    Williams, D.R.3    Cox, I.G.4
  • 6
    • 79960646460 scopus 로고    scopus 로고
    • Imaging single cells in the living retina
    • Williams, D.R. Imaging single cells in the living retina. Vis. Res. 2011, 51, 1379-1396.
    • (2011) Vis. Res. , vol.51 , pp. 1379-1396
    • Williams, D.R.1
  • 9
    • 0036072963 scopus 로고    scopus 로고
    • Ocular wave-front aberration statistics in a normal young population
    • Castejon-Mochón, J.F.; López-Gil, N.; Benito, A.; Artal, P. Ocular wave-front aberration statistics in a normal young population. Vis. Res. 2002, 42, 1611-1617.
    • (2002) Vis. Res. , vol.42 , pp. 1611-1617
    • Castejon-Mochón, J.F.1    López-Gil, N.2    Benito, A.3    Artal, P.4
  • 10
    • 0035434886 scopus 로고    scopus 로고
    • Monochromatic aberrations of the human eye in a large population
    • Porter, J.; Guirao, A.; Cox, I.G.; Williams, D.R. Monochromatic aberrations of the human eye in a large population. JOSA A 2001, 18, 1793-1803.
    • (2001) JOSA A , vol.18 , pp. 1793-1803
    • Porter, J.1    Guirao, A.2    Cox, I.G.3    Williams, D.R.4
  • 11
    • 0033786316 scopus 로고    scopus 로고
    • The prospects for perfect vision
    • Thibos, L.N. The prospects for perfect vision. J. Refract. Surg. 2000, 16, S540-S546.
    • (2000) J. Refract. Surg. , vol.16
    • Thibos, L.N.1
  • 12
    • 0036731079 scopus 로고    scopus 로고
    • A statistical model of the aberration structure of normal, well-corrected eyes
    • Thibos, L.N.; Bradley, A.; Hong, X. A statistical model of the aberration structure of normal, well-corrected eyes. Ophthalmic Physl. Opt. 2002, 22, 427-433.
    • (2002) Ophthalmic Physl. Opt. , vol.22 , pp. 427-433
    • Thibos, L.N.1    Bradley, A.2    Hong, X.3
  • 13
    • 33751345891 scopus 로고    scopus 로고
    • Normal-Eye zernike coefficients and root-mean-square wavefront errors
    • Salmon, T.O.; Van de Pol, C. Normal-Eye zernike coefficients and root-mean-square wavefront errors. J. Cataract Refract. Surg. 2006, 32, 2064-2074.
    • (2006) J. Cataract Refract. Surg. , vol.32 , pp. 2064-2074
    • Salmon, T.O.1    Van de Pol, C.2
  • 14
    • 0036362468 scopus 로고    scopus 로고
    • Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes
    • Guirao, A.; Porter, J.; Williams, D.R.; Cox, I.G. Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes. JOSA A 2002, 19, 1-9.
    • (2002) JOSA A , vol.19 , pp. 1-9
    • Guirao, A.1    Porter, J.2    Williams, D.R.3    Cox, I.G.4
  • 15
    • 0038656673 scopus 로고    scopus 로고
    • Changes of higher order aberration with various pupil sizes in myopic eyes
    • Wang, Y.; Zhao, K.; Jin, Y.; Zuo, T. Changes of higher order aberration with various pupil sizes in myopic eyes. J. Refract. Surg. 2003, 19, S270-S274.
    • (2003) J. Refract. Surg. , vol.19
    • Wang, Y.1    Zhao, K.2    Jin, Y.3    Zuo, T.4
  • 18
    • 33845437587 scopus 로고    scopus 로고
    • Changes in aberration and retinal image quality due to tear film dynamics
    • Li, K.; Yoon, G. Changes in aberration and retinal image quality due to tear film dynamics. Opt. Express 2006, 14, 12552-12559.
    • (2006) Opt. Express , vol.14 , pp. 12552-12559
    • Li, K.1    Yoon, G.2
  • 19
    • 84975563721 scopus 로고
    • Active optical depth resolution improvement of the laser tomographic scanner
    • Dreher, A.W.; Bille, J.F.; Weinreb, R.N. Active optical depth resolution improvement of the laser tomographic scanner. Appl. Opt. 1989, 28, 804-808.
    • (1989) Appl. Opt. , vol.28 , pp. 804-808
    • Dreher, A.W.1    Bille, J.F.2    Weinreb, R.N.3
  • 20
    • 0031260752 scopus 로고    scopus 로고
    • Supernormal and high-resolution retinal imaging through adaptive optics
    • Liang, J.; Miller, D.T.; Williams, D.R. Supernormal and high-resolution retinal imaging through adaptive optics. JOSA A 1997, 14, 2884-2892.
    • (1997) JOSA A , vol.14 , pp. 2884-2892
    • Liang, J.1    Miller, D.T.2    Williams, D.R.3
  • 21
    • 84857609754 scopus 로고    scopus 로고
    • Reflective afocal broadband adaptive optics scanning ophthalmoscope
    • Dubra, A.; Sulai, Y. Reflective afocal broadband adaptive optics scanning ophthalmoscope. Biomed. Opt. Express 2011, 2, 1757-1768.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1757-1768
    • Dubra, A.1    Sulai, Y.2
  • 22
    • 79952585675 scopus 로고    scopus 로고
    • Adaptive optics and the eye (super resolution OCT)
    • Miller, D.T.; Kocaoglu, O.P.; Wang, Q.; Lee, S. Adaptive optics and the eye (super resolution OCT). Eye 2011, 25, 321-330.
    • (2011) Eye , vol.25 , pp. 321-330
    • Miller, D.T.1    Kocaoglu, O.P.2    Wang, Q.3    Lee, S.4
  • 23
    • 2942622023 scopus 로고    scopus 로고
    • Functional photoreceptor loss revealed with adaptive optics: An alternate cause of color blindness
    • Carroll, J.; Neitz, M.; Hofer, H.; Neitz, J.; Williams, D.R. Functional photoreceptor loss revealed with adaptive optics: An alternate cause of color blindness. PNAS 2004, 101, 8461-8466.
    • (2004) PNAS , vol.101 , pp. 8461-8466
    • Carroll, J.1    Neitz, M.2    Hofer, H.3    Neitz, J.4    Williams, D.R.5
  • 25
    • 67849119909 scopus 로고    scopus 로고
    • New methods and techniques for sensing the wave aberration of human eyes
    • Lombardo, M.; Lombardo, G. New methods and techniques for sensing the wave aberration of human eyes. Clin. Exp. Optom. 2009, 92, 176-186.
    • (2009) Clin. Exp. Optom. , vol.92 , pp. 176-186
    • Lombardo, M.1    Lombardo, G.2
  • 26
    • 0028469062 scopus 로고
    • Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor
    • Liang, J.; Grimm, B.; Goelz, S.; Billie, J.F. Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. JOSA A 1994, 11, 1949-1957.
    • (1994) JOSA A , vol.11 , pp. 1949-1957
    • Liang, J.1    Grimm, B.2    Goelz, S.3    Billie, J.F.4
  • 27
    • 0034832891 scopus 로고    scopus 로고
    • History and principles of Shack-Hartmann wavefront sensing
    • Platt, R.; Shack, R. History and principles of Shack-Hartmann wavefront sensing. J. Refract. Surg. 2001, 17, S573-S577.
    • (2001) J. Refract. Surg. , vol.17
    • Platt, R.1    Shack, R.2
  • 28
    • 67949085909 scopus 로고    scopus 로고
    • Dynamic range expansion of a shack-hartmann sensor by use of a modified unwrapping algorithm
    • Pfund, J.; Lindlein, N.; Schwider, J. Dynamic range expansion of a shack-hartmann sensor by use of a modified unwrapping algorithm. Opt. Lett. 2000, 39, 561-567.
    • (2000) Opt. Lett. , vol.39 , pp. 561-567
    • Pfund, J.1    Lindlein, N.2    Schwider, J.3
  • 29
    • 0036744783 scopus 로고    scopus 로고
    • Higher order aberrations in normal, dilated, intraocular lens, and laser in situ keratomileusis corneas
    • Miller, J.M.; Anwaruddin, R.; Straub, J.; Schwiegerling, J. Higher order aberrations in normal, dilated, intraocular lens, and laser in situ keratomileusis corneas. J. Refract. Surg. 2002, 18, S579-S583.
    • (2002) J. Refract. Surg. , vol.18
    • Miller, J.M.1    Anwaruddin, R.2    Straub, J.3    Schwiegerling, J.4
  • 32
    • 33748448116 scopus 로고    scopus 로고
    • Large-Dynamic-Range shack-hartmann wavefront sensor for highly aberrated eyes
    • Yoon, G.; Pantanelli, S.; Nagy, L.J. Large-Dynamic-Range shack-hartmann wavefront sensor for highly aberrated eyes. J. Biomed. Opt. 2006, 11, 30502.
    • (2006) J. Biomed. Opt. , vol.11 , pp. 30502
    • Yoon, G.1    Pantanelli, S.2    Nagy, L.J.3
  • 33
    • 0020180312 scopus 로고
    • Phase retrieval and diversity in adaptive optics
    • Gonsalves, R.A. Phase retrieval and diversity in adaptive optics. Opt. Eng. 1982, 21, 829-832.
    • (1982) Opt. Eng. , vol.21 , pp. 829-832
    • Gonsalves, R.A.1
  • 34
    • 0020173780 scopus 로고
    • Phase retrieval algorithms: A comparison
    • Fienup, J.R. Phase retrieval algorithms: A comparison. Appl. Opt. 1982, 21, 2758-2769.
    • (1982) Appl. Opt. , vol.21 , pp. 2758-2769
    • Fienup, J.R.1
  • 35
    • 0020849487 scopus 로고
    • Deterministic phase retrieval: A Green's function solution
    • Teague, M.R. Deterministic phase retrieval: A Green's function solution. JOSA A 1983, 73, 1434-1441.
    • (1983) JOSA A , vol.73 , pp. 1434-1441
    • Teague, M.R.1
  • 36
    • 84975661943 scopus 로고
    • Phase retrieval with the transport-of-intensity equation: Matrix solution with use of Zernike polynomials
    • Gureyev, T.E.; Roberts, A.; Nugent, A. Phase retrieval with the transport-of-intensity equation: Matrix solution with use of Zernike polynomials. JOSA A 1995, 12, 1932-1941.
    • (1995) JOSA A , vol.12 , pp. 1932-1941
    • Gureyev, T.E.1    Roberts, A.2    Nugent, A.3
  • 37
    • 0000209681 scopus 로고    scopus 로고
    • Phase retrieval with the transport-of-intensity equation. II. orthogonal series solution for nonuniform illumination
    • Gureyev, T.E.; Nugent, A. Phase retrieval with the transport-of-intensity equation. II. orthogonal series solution for nonuniform illumination. JOSA A 1996, 13, 1670-1682.
    • (1996) JOSA A , vol.13 , pp. 1670-1682
    • Gureyev, T.E.1    Nugent, A.2
  • 38
    • 84975654195 scopus 로고
    • Curvature sensing and compensation: A new concept in adaptive optics
    • Roddier, F. Curvature sensing and compensation: A new concept in adaptive optics. Appl. Opt. 1988, 27, 1223-1225.
    • (1988) Appl. Opt. , vol.27 , pp. 1223-1225
    • Roddier, F.1
  • 39
    • 33748688477 scopus 로고    scopus 로고
    • Curvature sensor for ocular wavefront measurement
    • Diaz-Douton, F.; Pujol, J.; Arjona, M.; Luque, S.O. Curvature sensor for ocular wavefront measurement. Opt. Lett. 2006, 31, 2245-2247.
    • (2006) Opt. Lett. , vol.31 , pp. 2245-2247
    • Diaz-Douton, F.1    Pujol, J.2    Arjona, M.3    Luque, S.O.4
  • 40
    • 0000465737 scopus 로고    scopus 로고
    • Pupil plane wavefront sensing with an oscillating prism 1996
    • Ragazzoni, R. Pupil plane wavefront sensing with an oscillating prism 1996. J. Mod. Opt. 1996, 43, 289-293.
    • (1996) J. Mod. Opt. , vol.43 , pp. 289-293
    • Ragazzoni, R.1
  • 41
    • 0001329336 scopus 로고    scopus 로고
    • Sensitivity of a pyramidic wave front sensor in closed loop adaptive optics
    • Ragazzoni, R.; Farinato, J. Sensitivity of a pyramidic wave front sensor in closed loop adaptive optics. Astron. Astrophys. 1999, 350, L23-L26.
    • (1999) Astron. Astrophys. , vol.350
    • Ragazzoni, R.1    Farinato, J.2
  • 42
    • 0347807303 scopus 로고    scopus 로고
    • Extended source pyramid wave-front sensor for the human eye
    • Iglesias, I.; Ragazzoni, R.; Julien, Y.; Artal, P. Extended source pyramid wave-front sensor for the human eye. Opt. Express 2002, 10, 419-428.
    • (2002) Opt. Express , vol.10 , pp. 419-428
    • Iglesias, I.1    Ragazzoni, R.2    Julien, Y.3    Artal, P.4
  • 43
    • 31144470478 scopus 로고    scopus 로고
    • Adaptive optics for ophthalmic applications using a pyramid wavefront sensor
    • Chamot, S.R.; Dainty, C.; Esposito, S. Adaptive optics for ophthalmic applications using a pyramid wavefront sensor. Opt. Express 2006, 2, 518-526.
    • (2006) Opt. Express , vol.2 , pp. 518-526
    • Chamot, S.R.1    Dainty, C.2    Esposito, S.3
  • 44
    • 0000611140 scopus 로고    scopus 로고
    • Wavefront analysis with high accuracy by use of a double-grating lateral shearing interferometer
    • Leibbrandt, G.W.R.; Harbers, G.; Kunst, P.J. Wavefront analysis with high accuracy by use of a double-grating lateral shearing interferometer. Appl. Opt. 1996, 35, 6151-6161.
    • (1996) Appl. Opt. , vol.35 , pp. 6151-6161
    • Leibbrandt, G.W.R.1    Harbers, G.2    Kunst, P.J.3
  • 45
    • 0000710090 scopus 로고    scopus 로고
    • Speckle shearing interferometry using a diffractive optical beamsplitter
    • Gundlach, A.; Huntley, J.M.; Manzke, B.; Schwider, J. Speckle shearing interferometry using a diffractive optical beamsplitter. Opt. Eng. 1997, 36, 1488-1493.
    • (1997) Opt. Eng. , vol.36 , pp. 1488-1493
    • Gundlach, A.1    Huntley, J.M.2    Manzke, B.3    Schwider, J.4
  • 46
    • 0002521438 scopus 로고    scopus 로고
    • Phase-Shifting shearing interferometer
    • Griffin, D.W. Phase-Shifting shearing interferometer. Opt. Lett. 2001, 26, 140-141.
    • (2001) Opt. Lett. , vol.26 , pp. 140-141
    • Griffin, D.W.1
  • 47
    • 0001296165 scopus 로고    scopus 로고
    • Analysis of lateral shearing interferograms by use of Zernike polynomials
    • Harbers, G.; Kunst, P.J.; Leibbrandt, W.R. Analysis of lateral shearing interferograms by use of Zernike polynomials. Appl. Opt. 1996, 35, 6162-6172.
    • (1996) Appl. Opt. , vol.35 , pp. 6162-6172
    • Harbers, G.1    Kunst, P.J.2    Leibbrandt, W.R.3
  • 48
    • 60949111403 scopus 로고    scopus 로고
    • Integrated diffractive shearing interferometry for adaptive wavefront sensing
    • Karp, J.H.; Chan, T.K.; Ford, J.E. Integrated diffractive shearing interferometry for adaptive wavefront sensing. Appl. Opt. 2008, 35, 6666-6674.
    • (2008) Appl. Opt. , vol.35 , pp. 6666-6674
    • Karp, J.H.1    Chan, T.K.2    Ford, J.E.3
  • 49
    • 15944400334 scopus 로고    scopus 로고
    • Multiple-Wave lateral shearing interferometry for wavefront sensing
    • Chanteloup, J.C. Multiple-Wave lateral shearing interferometry for wavefront sensing. Appl. Opt. 2005, 44, 1559-1571.
    • (2005) Appl. Opt. , vol.44 , pp. 1559-1571
    • Chanteloup, J.C.1
  • 50
    • 0035879479 scopus 로고    scopus 로고
    • A wavefront sensor based on the fractional talbot effect
    • Siegel, C.; Loewenthal, F.; Balmer, J.E. A wavefront sensor based on the fractional talbot effect. Opt. Commun. 2001, 194, 265-275.
    • (2001) Opt. Commun. , vol.194 , pp. 265-275
    • Siegel, C.1    Loewenthal, F.2    Balmer, J.E.3
  • 51
    • 0021455243 scopus 로고
    • Measurements of phase objects using the Talbot effect and moiré techniques
    • Nakano, Y.; Murata, K. Measurements of phase objects using the Talbot effect and moiré techniques. Appl. Opt. 1984, 23, 2296-2299.
    • (1984) Appl. Opt. , vol.23 , pp. 2296-2299
    • Nakano, Y.1    Murata, K.2
  • 54
    • 39149123178 scopus 로고    scopus 로고
    • Performance of a new binocular wavefront aberrometer based on a self-imaging diffractive sensor
    • Warden, L.; Liu, Y.; Binder, P.S.; Dreher, A.W.; Sverdrup, L. Performance of a new binocular wavefront aberrometer based on a self-imaging diffractive sensor. J. Refract. Surg. 2008, 24, 188-196.
    • (2008) J. Refract. Surg. , vol.24 , pp. 188-196
    • Warden, L.1    Liu, Y.2    Binder, P.S.3    Dreher, A.W.4    Sverdrup, L.5
  • 55
    • 4644260470 scopus 로고    scopus 로고
    • Adaptive optics with a programmable phase modulator: Applications in the human eye
    • Prieto, P.; Fernández, E.; Manzanera, S.; Artal, P. Adaptive optics with a programmable phase modulator: Applications in the human eye. Opt. Exp. 2004, 12, 4059-4071
    • (2004) Opt. Exp. , vol.12 , pp. 4059-4071
    • Prieto, P.1    Fernández, E.2    Manzanera, S.3    Artal, P.4
  • 56
    • 78149318396 scopus 로고    scopus 로고
    • Adaptive optics binocular visual simulator to study stereopsis in the presence of aberrations
    • Fernández, E.; Prieto, P.; Artal, P. Adaptive optics binocular visual simulator to study stereopsis in the presence of aberrations. JOSA A 2010, 27, A48-A55.
    • (2010) JOSA A , vol.27
    • Fernández, E.1    Prieto, P.2    Artal, P.3
  • 57
    • 84864516452 scopus 로고    scopus 로고
    • Optimization of the open-loop liquid crystal adaptive optics retinal imaging system
    • Kong, N.; Li, C.; Xia, M.; Li, D.; Qi, Y.; Xuan, L. Optimization of the open-loop liquid crystal adaptive optics retinal imaging system. J. Biomed. Opt. 2012, doi:10.1117/1.JBO.17.2.026001.
    • (2012) J. Biomed. Opt.
    • Kong, N.1    Li, C.2    Xia, M.3    Li, D.4    Qi, Y.5    Xuan, L.6
  • 58
    • 70349675148 scopus 로고    scopus 로고
    • Topical review: Adaptive optics and vision
    • Hampson, K. Topical review: Adaptive optics and vision. J. Mod. Opt. 2008, 55, 3425-3467.
    • (2008) J. Mod. Opt. , vol.55 , pp. 3425-3467
    • Hampson, K.1
  • 60
    • 21244481527 scopus 로고    scopus 로고
    • Characterisation for vision science applications of a bimorph deformable mirror using phase-shifting interferometry
    • Horsley, D.; Park, H.; Laut, S.; Wernet, J. Characterisation for vision science applications of a bimorph deformable mirror using phase-shifting interferometry. Proc. SPIE 2005, 5688, 133-144.
    • (2005) Proc. SPIE , vol.5688 , pp. 133-144
    • Horsley, D.1    Park, H.2    Laut, S.3    Wernet, J.4
  • 61
    • 34249686102 scopus 로고    scopus 로고
    • High-Resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrors
    • Chen, D.; Jones, S.; Silva, D.; Olivier, S. High-Resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrors. JOSA A 2007, 24, 1305-1312.
    • (2007) JOSA A , vol.24 , pp. 1305-1312
    • Chen, D.1    Jones, S.2    Silva, D.3    Olivier, S.4
  • 62
    • 84975612628 scopus 로고
    • Flexible mirror micromachined in silicon
    • Vdovin, G.; Sarro, P. Flexible mirror micromachined in silicon. Appl. Opt. 1995, 34, 2968-2972.
    • (1995) Appl. Opt. , vol.34 , pp. 2968-2972
    • Vdovin, G.1    Sarro, P.2
  • 63
    • 33845460274 scopus 로고    scopus 로고
    • Push-Pull membrane mirrors for adaptive optics
    • Bonora, S.; Poletto, L. Push-Pull membrane mirrors for adaptive optics. Opt. Express 2006, 14, 11935-11944.
    • (2006) Opt. Express , vol.14 , pp. 11935-11944
    • Bonora, S.1    Poletto, L.2
  • 64
    • 84857614221 scopus 로고    scopus 로고
    • High resolution wavefront correction with photocontrolled deformable mirror
    • Bonora, S.; Coburn, D.; Bortolozzo, U.; Dainty, C.; Residori, S. High resolution wavefront correction with photocontrolled deformable mirror. Opt. Express 2012, 20, 5178-5188.
    • (2012) Opt. Express , vol.20 , pp. 5178-5188
    • Bonora, S.1    Coburn, D.2    Bortolozzo, U.3    Dainty, C.4    Residori, S.5
  • 65
    • 0036993254 scopus 로고    scopus 로고
    • Micromachined deformable mirrors for adaptive optics
    • Bifano, T.; Perreault, J.; Bierden, P.; Dimas, C. Micromachined deformable mirrors for adaptive optics. Proc. SPIE 2002, 4825, 10-13.
    • (2002) Proc. SPIE , vol.4825 , pp. 10-13
    • Bifano, T.1    Perreault, J.2    Bierden, P.3    Dimas, C.4
  • 69
    • 70350302342 scopus 로고    scopus 로고
    • Closed-Loop control of magnetic fluid deformable mirrors
    • Iqbal, A.; Wu, Z.; Amara, F. Closed-Loop control of magnetic fluid deformable mirrors. Opt. Express 2009, 17, 18597-18970.
    • (2009) Opt. Express , vol.17 , pp. 18597-18970
    • Iqbal, A.1    Wu, Z.2    Amara, F.3
  • 70
    • 60249092143 scopus 로고    scopus 로고
    • Closed-loop adaptive optical system with a liquid mirror
    • Vdovin, G. Closed-loop adaptive optical system with a liquid mirror. Opt. Lett. 2009, 34, 524-526.
    • (2009) Opt. Lett. , vol.34 , pp. 524-526
    • Vdovin, G.1
  • 71
    • 60949094788 scopus 로고    scopus 로고
    • Correction of ocular and atmospheric wavefronts: A comparison of the performance of various deformable mirrors
    • Devaney, N.; Dalimier, E.; Farrell, T.; Coburn, D.; Mackey, R.; Mackey, D.; Laurent, F.; Daly, E.; Dainty, C. Correction of ocular and atmospheric wavefronts: A comparison of the performance of various deformable mirrors. Appl. Opt. 2008, 47, 6550-6562.
    • (2008) Appl. Opt. , vol.47 , pp. 6550-6562
    • Devaney, N.1    Dalimier, E.2    Farrell, T.3    Coburn, D.4    Mackey, R.5    Mackey, D.6    Laurent, F.7    Daly, E.8    Dainty, C.9
  • 72
    • 0020644382 scopus 로고
    • The directional sensitivity of retinal rods
    • Alpern, M.; Ching, C.C.; Kitahara, K. The directional sensitivity of retinal rods. J. Physiol. 1983, 343, 577-592.
    • (1983) J. Physiol. , vol.343 , pp. 577-592
    • Alpern, M.1    Ching, C.C.2    Kitahara, K.3
  • 73
    • 55149089278 scopus 로고    scopus 로고
    • In vivo imaging of the photoreceptor mosaic of a rod monochromat
    • Carroll, J.; Choi, S.S.; Williams, D.R. In vivo imaging of the photoreceptor mosaic of a rod monochromat. Vis. Res. 2008, 48, 2564-2568.
    • (2008) Vis. Res. , vol.48 , pp. 2564-2568
    • Carroll, J.1    Choi, S.S.2    Williams, D.R.3
  • 74
    • 82255164373 scopus 로고    scopus 로고
    • Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope
    • Dubra, A.; Sulai, Y.; Norris, J.L.; Cooper, R.F.; Dubis, A.M.; Williams, D.R.; Carroll, J. Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope. Biomed. Opt. Express 2011, 2, 1864-1876.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1864-1876
    • Dubra, A.1    Sulai, Y.2    Norris, J.L.3    Cooper, R.F.4    Dubis, A.M.5    Williams, D.R.6    Carroll, J.7
  • 77
    • 34249693108 scopus 로고    scopus 로고
    • Automated identification of cone photoreceptors in adaptive optics retinal images
    • Li, K.Y.; Roorda, A. Automated identification of cone photoreceptors in adaptive optics retinal images. JOSA A 2007, 24, 1358-1363.
    • (2007) JOSA A , vol.24 , pp. 1358-1363
    • Li, K.Y.1    Roorda, A.2
  • 78
    • 34249658501 scopus 로고    scopus 로고
    • Photoreceptor counting and montaging of en-face retinal images from an adaptive optics fundus camera
    • Xue, B.; Choi, S.S.; Doble, N.; Werner, J.S. Photoreceptor counting and montaging of en-face retinal images from an adaptive optics fundus camera. JOSA A 2007, 24, 1364-1372.
    • (2007) JOSA A , vol.24 , pp. 1364-1372
    • Xue, B.1    Choi, S.S.2    Doble, N.3    Werner, J.S.4
  • 79
    • 47549086903 scopus 로고    scopus 로고
    • Automated analysis of differential interference contrast microscopy images of the foveal cone mosaic
    • Wojtas, D.H.; Wu, B.; Ahnelt, P.K.; Bones, P.J.; Millane, R.P. Automated analysis of differential interference contrast microscopy images of the foveal cone mosaic. JOSA A 2008, 25, 1181-1189.
    • (2008) JOSA A , vol.25 , pp. 1181-1189
    • Wojtas, D.H.1    Wu, B.2    Ahnelt, P.K.3    Bones, P.J.4    Millane, R.P.5
  • 80
    • 0026110523 scopus 로고
    • The density recovery profile: A method for the analysis of points in the plane applicable to retinal studies
    • Rodieck, R.W. The density recovery profile: A method for the analysis of points in the plane applicable to retinal studies. Vis. Neurosci. 1991, 6, 95-111.
    • (1991) Vis. Neurosci. , vol.6 , pp. 95-111
    • Rodieck, R.W.1
  • 82
    • 53449091924 scopus 로고    scopus 로고
    • Individual variations in human cone photoreceptor packing density: Variations with refractive error
    • Chui, T.Y.P.; Song, H.; Burns, S. Individual variations in human cone photoreceptor packing density: Variations with refractive error. Invest. Ophthalmol. Vis. Sci. 2008, 49, 4679-4687.
    • (2008) Invest. Ophthalmol. Vis. Sci. , vol.49 , pp. 4679-4687
    • Chui, T.Y.P.1    Song, H.2    Burns, S.3
  • 83
    • 78651477561 scopus 로고    scopus 로고
    • Intersubject variability of foveal cone photoreceptor density in relation to eye length
    • Li, K.Y.; Tiruveedhula, P.; Roorda, A. Intersubject variability of foveal cone photoreceptor density in relation to eye length. Invest. Ophthalmol. Vis. Sci. 2010, 51, 6858-6867.
    • (2010) Invest. Ophthalmol. Vis. Sci. , vol.51 , pp. 6858-6867
    • Li, K.Y.1    Tiruveedhula, P.2    Roorda, A.3
  • 84
    • 60549097114 scopus 로고    scopus 로고
    • Adaptive-Optics imaging of human cone photoreceptor distribution
    • Chui, T.Y.P.; Song, H.; Burns, S. Adaptive-Optics imaging of human cone photoreceptor distribution. JOSA A 2008, 25, 3021-3029.
    • (2008) JOSA A , vol.25 , pp. 3021-3029
    • Chui, T.Y.P.1    Song, H.2    Burns, S.3
  • 85
    • 84856402583 scopus 로고    scopus 로고
    • Variation of cone photoreceptor packing density with retinal eccentricity and age
    • Song, H.; Chui, T.Y.P.; Zhong. Z.; Elsner, A.E.; Burns, S.A. Variation of cone photoreceptor packing density with retinal eccentricity and age. Invest. Ophthalmol. Vis. Sci. 2011, 52, 7376-7384.
    • (2011) Invest. Ophthalmol. Vis. Sci. , vol.52 , pp. 7376-7384
    • Song, H.1    Chui, T.Y.P.2    Zhong, Z.3    Elsner, A.E.4    Burns, S.A.5
  • 87
    • 0026905749 scopus 로고
    • Packing geometry of human cone photoreceptors: Variation with eccentricity and evidence of local anisotropy
    • Curcio, C.A.; Sloan, K.R. Packing geometry of human cone photoreceptors: variation with eccentricity and evidence of local anisotropy. Vis. Neurosci. 1992, 9, 169-180.
    • (1992) Vis. Neurosci. , vol.9 , pp. 169-180
    • Curcio, C.A.1    Sloan, K.R.2
  • 88
    • 0023272184 scopus 로고
    • Distribution of cones in human and monkey retina: Individual variability and radial asymmetry
    • Curcio, C.A.; Sloan, K.R.; Packer, O.; Hendrickson, A.E.; Kalina, R.E. Distribution of cones in human and monkey retina: Individual variability and radial asymmetry. Science 1987, 236, 579-582.
    • (1987) Science , vol.236 , pp. 579-582
    • Curcio, C.A.1    Sloan, K.R.2    Packer, O.3    Hendrickson, A.E.4    Kalina, R.E.5
  • 89
    • 0001897347 scopus 로고
    • Topography of the layer of rods and cones in the human retina
    • Østerberg, G.A. Topography of the layer of rods and cones in the human retina. Acta Ophthalmol. 1935, 13, 1-97.
    • (1935) Acta Ophthalmol. , vol.13 , pp. 1-97
    • Østerberg, G.A.1
  • 91
    • 84862861547 scopus 로고    scopus 로고
    • Variations in the image optical quality of the eye and the sampling limit of resolution of the cone mosaic with axial length in young adults
    • Lombardo, M.; Serrao, S.; Ducoli, P.; Lombardo, G. Variations in the image optical quality of the eye and the sampling limit of resolution of the cone mosaic with axial length in young adults. J. Cataract Refract. Surg. 2012, 38, 1147-1155.
    • (2012) J. Cataract Refract. Surg. , vol.38 , pp. 1147-1155
    • Lombardo, M.1    Serrao, S.2    Ducoli, P.3    Lombardo, G.4
  • 92
    • 29144522927 scopus 로고    scopus 로고
    • Effect of myopia on visual acuity measured with laser interference fringes
    • Coletta, N.J.; Watson, T. Effect of myopia on visual acuity measured with laser interference fringes. Vis. Res. 2006, 46, 636-651.
    • (2006) Vis. Res. , vol.46 , pp. 636-651
    • Coletta, N.J.1    Watson, T.2
  • 93
    • 75549091329 scopus 로고    scopus 로고
    • The relationship between visual resolution and cone spacing in the human fovea
    • Rossi, E.A.; Roorda, A. The relationship between visual resolution and cone spacing in the human fovea. Nat. Neurosci. 2010, 13, 156-157.
    • (2010) Nat. Neurosci. , vol.13 , pp. 156-157
    • Rossi, E.A.1    Roorda, A.2
  • 94
    • 0344258189 scopus 로고    scopus 로고
    • Quantitative estimations of foveal and extra-foveal retinal circuitry in humans
    • Sjöstrand, J.; Olsson, V.; Popovic, Z.; Conradi, N. Quantitative estimations of foveal and extra-foveal retinal circuitry in humans. Vis. Res. 1999, 39, 2987-2998.
    • (1999) Vis. Res. , vol.39 , pp. 2987-2998
    • Sjöstrand, J.1    Olsson, V.2    Popovic, Z.3    Conradi, N.4
  • 95
    • 34548797015 scopus 로고    scopus 로고
    • The length of Henle fibers in the human retina and a model of ganglion receptive field density in the visual field
    • Drasdo, N.; Millican, C.L.; Katholi, C.R.; Curcio, C.A. The length of Henle fibers in the human retina and a model of ganglion receptive field density in the visual field. Vis. Res. 2007, 47, 2901-2911.
    • (2007) Vis. Res. , vol.47 , pp. 2901-2911
    • Drasdo, N.1    Millican, C.L.2    Katholi, C.R.3    Curcio, C.A.4
  • 98
    • 36749089929 scopus 로고    scopus 로고
    • In vivo functional imaging of human cone photoreceptors
    • Ravi, S.J.; Rha, J.; Zhang, Y.; Cense, B.; Gao, W.; Miller, D.T. In vivo functional imaging of human cone photoreceptors. Opt. Express 2007, 15, 16141-16160.
    • (2007) Opt. Express , vol.15 , pp. 16141-16160
    • Ravi, S.J.1    Rha, J.2    Zhang, Y.3    Cense, B.4    Gao, W.5    Miller, D.T.6
  • 99
    • 84861095948 scopus 로고    scopus 로고
    • Spatial and temporal variation of rod photoreceptor reflectance in the human retina
    • Cooper, R.F.; Dubis, A.M.; Pavaskar, A.; Rha, J.; Dubra, A.; Carroll, J. Spatial and temporal variation of rod photoreceptor reflectance in the human retina. Biomed. Opt. Express 2011, 2, 2577-2589.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 2577-2589
    • Cooper, R.F.1    Dubis, A.M.2    Pavaskar, A.3    Rha, J.4    Dubra, A.5    Carroll, J.6
  • 100
    • 72649102474 scopus 로고    scopus 로고
    • Variable optical activation of human cone photoreceptors visualized using a short coherence light source
    • Rha, J.; Schroeder, B.; Godara, P.; Carroll, J. Variable optical activation of human cone photoreceptors visualized using a short coherence light source. Opt. Lett. 2009, 34, 3782-3784.
    • (2009) Opt. Lett. , vol.34 , pp. 3782-3784
    • Rha, J.1    Schroeder, B.2    Godara, P.3    Carroll, J.4
  • 101
    • 30844469964 scopus 로고    scopus 로고
    • Effect of wavelength on in vivo images of the human cone mosaic
    • Choi, S.S.; Doble, N.; Lin, J.; Christou, J.; Williams, D.R. Effect of wavelength on in vivo images of the human cone mosaic. JOSA A 2005, 22, 2598-2605.
    • (2005) JOSA A , vol.22 , pp. 2598-2605
    • Choi, S.S.1    Doble, N.2    Lin, J.3    Christou, J.4    Williams, D.R.5
  • 102
    • 79960644784 scopus 로고    scopus 로고
    • Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics
    • Kocaoglu, O.P.; Lee, S.; Jonnal, R.S.; Wang, Q.; Herde, A.E.; Derby, J.C.; Gao, W.; Miller, D.T. Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics. Biomed. Opt. Express 2011, 2, 748-763.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 748-763
    • Kocaoglu, O.P.1    Lee, S.2    Jonnal, R.S.3    Wang, Q.4    Herde, A.E.5    Derby, J.C.6    Gao, W.7    Miller, D.T.8
  • 104
    • 33646560306 scopus 로고    scopus 로고
    • Adaptive optics flood-illumination camera for high-speed retinal imaging
    • Rha, J.; Jonnal, R.S.; Thorn, K.E.; Qu, J.; Zhang, Y.; Miller, D.T. Adaptive optics flood-illumination camera for high-speed retinal imaging. Opt. Express 2006, 14, 4552-4569.
    • (2006) Opt. Express , vol.14 , pp. 4552-4569
    • Rha, J.1    Jonnal, R.S.2    Thorn, K.E.3    Qu, J.4    Zhang, Y.5    Miller, D.T.6
  • 105
    • 84891493462 scopus 로고    scopus 로고
    • Optical fiber properties of individual human cones
    • Roorda, A.; Williams, D.R. Optical fiber properties of individual human cones. J. Vis. 2002, 35, 607-614.
    • (2002) J. Vis. , vol.35 , pp. 607-614
    • Roorda, A.1    Williams, D.R.2
  • 106
    • 0031230738 scopus 로고    scopus 로고
    • Variations in photoreceptor directionality across the central retina
    • Burns, S.A.; Wu, S.; He, J.C.; Elsner, A.E. Variations in photoreceptor directionality across the central retina. JOSA A 1997, 14, 2033-2040.
    • (1997) JOSA A , vol.14 , pp. 2033-2040
    • Burns, S.A.1    Wu, S.2    He, J.C.3    Elsner, A.E.4
  • 107
    • 0033208855 scopus 로고    scopus 로고
    • Comparison of cone directionality determined by psychophysical and reflectometric techniques
    • He, J.C.; Marcos, S.; Burns, S.A. Comparison of cone directionality determined by psychophysical and reflectometric techniques. JOSA A 1999, 16, 2363-2369.
    • (1999) JOSA A , vol.16 , pp. 2363-2369
    • He, J.C.1    Marcos, S.2    Burns, S.A.3
  • 108
    • 84865811140 scopus 로고    scopus 로고
    • Analysis of individual cone-photoreceptor directionality using scanning laser ophthalmoscopy
    • Rativa, D.; Vohnsen, B. Analysis of individual cone-photoreceptor directionality using scanning laser ophthalmoscopy. Biomed. Opt. Express 2011, 2, 1423-1431.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1423-1431
    • Rativa, D.1    Vohnsen, B.2
  • 109
    • 0030787387 scopus 로고    scopus 로고
    • Foveal cone spacing and cone photopigment density difference: Objective measurements in the same subjects
    • Marcos, S.; Tornow, R.P.; Elsner, A.E.; Navarro, R. Foveal cone spacing and cone photopigment density difference: objective measurements in the same subjects. Vis. Res. 1997, 37, 1909-1915.
    • (1997) Vis. Res. , vol.37 , pp. 1909-1915
    • Marcos, S.1    Tornow, R.P.2    Elsner, A.E.3    Navarro, R.4
  • 112
    • 78650851495 scopus 로고    scopus 로고
    • Evidence of outer retinal changes in glaucoma patients as revealed by ultrahigh-resolution in vivo retinal imaging
    • Choi, S.S.; Zawadzki, R.J.; Lim, M.C.; Brandt, J.D.; Keltner, J.L.; Doble, N.; Werner, J.S. Evidence of outer retinal changes in glaucoma patients as revealed by ultrahigh-resolution in vivo retinal imaging. Br. J. Ophthalmol. 2011, 95, 131-141.
    • (2011) Br. J. Ophthalmol. , vol.95 , pp. 131-141
    • Choi, S.S.1    Zawadzki, R.J.2    Lim, M.C.3    Brandt, J.D.4    Keltner, J.L.5    Doble, N.6    Werner, J.S.7
  • 115
    • 61349121337 scopus 로고    scopus 로고
    • The wisconsin epidemiologic study of diabetic retinopathy xxiii: The twenty-five-year incidence of macular edema in persons with type 1 diabetes
    • Klein, R.; Knudtson, M.D.; Lee, K.E.; Gangnon, R.; Klein, B.E. The wisconsin epidemiologic study of diabetic retinopathy xxiii: The twenty-five-year incidence of macular edema in persons with type 1 diabetes. Ophthalmology 2009, 116, 497-503.
    • (2009) Ophthalmology , vol.116 , pp. 497-503
    • Klein, R.1    Knudtson, M.D.2    Lee, K.E.3    Gangnon, R.4    Klein, B.E.5
  • 116
    • 84861352773 scopus 로고    scopus 로고
    • Diabetes in numbers
    • Scully, T. Diabetes in numbers. Nature 2012, 485, S2-S3.
    • (2012) Nature , vol.485
    • Scully, T.1
  • 117
    • 0025760218 scopus 로고
    • Fundus photographic risk factors for progression of diabetic retinopathy. ETDRS Report Number 12
    • Early Treatment Diabetic Retinopathy Study Research Group
    • Early Treatment Diabetic Retinopathy Study Research Group. Fundus photographic risk factors for progression of diabetic retinopathy. ETDRS Report Number 12. Ophthalmology 1991, 98, 823-833.
    • (1991) Ophthalmology , vol.98 , pp. 823-833
  • 118
    • 0033047889 scopus 로고    scopus 로고
    • Three dimensional analysis of microaneurysms in the human diabetic retina
    • Moore, J.; Bagley, S.; Ireland, G.; McLeod, D.; Boulton, M.E. Three dimensional analysis of microaneurysms in the human diabetic retina. J. Anat. 1999, 194, 89-110.
    • (1999) J. Anat. , vol.194 , pp. 89-110
    • Moore, J.1    Bagley, S.2    Ireland, G.3    McLeod, D.4    Boulton, M.E.5
  • 119
    • 0028998575 scopus 로고
    • Vascular lesions in diabetes are distributed non-uniformly within the retina
    • Kern, T.S.; Engerman, R.L. Vascular lesions in diabetes are distributed non-uniformly within the retina. Exp. Eye Res. 1995, 60, 545-549.
    • (1995) Exp. Eye Res. , vol.60 , pp. 545-549
    • Kern, T.S.1    Engerman, R.L.2
  • 120
    • 0017872196 scopus 로고
    • Pathophysiology of diabetic retinopathy
    • Cunha-Vaz, J.G. Pathophysiology of diabetic retinopathy. Br. J. Ophthalmol. 1978, 62, 351-355.
    • (1978) Br. J. Ophthalmol. , vol.62 , pp. 351-355
    • Cunha-Vaz, J.G.1
  • 121
    • 0037376768 scopus 로고    scopus 로고
    • A new view of diabetic retinopathy: A neurodegenerative disease of the eye
    • Barber, A.J. A new view of diabetic retinopathy: a neurodegenerative disease of the eye. Prog. Neuro-Psych. Biol. Psych. 2003, 27, 283-290.
    • (2003) Prog. Neuro-Psych. Biol. Psych. , vol.27 , pp. 283-290
    • Barber, A.J.1
  • 122
    • 70349211901 scopus 로고    scopus 로고
    • Is neuronal dysfunction on early sign of diabetic retinopathy? Microperimetry and Spectral Domain Optical Coherence Tomography (SD-OCT) study in individuals with diabetes, but no diabetic retinopathy
    • Verma, A.; Rani, P.K.; Raman, R.; Pal, S.S.; Laxmi, G.; Gupta, M.; Sahu, C.; Vaitheeswaran, S.T. Is neuronal dysfunction on early sign of diabetic retinopathy? Microperimetry and Spectral Domain Optical Coherence Tomography (SD-OCT) study in individuals with diabetes, but no diabetic retinopathy. Eye 2009, 23, 1824-1830.
    • (2009) Eye , vol.23 , pp. 1824-1830
    • Verma, A.1    Rani, P.K.2    Raman, R.3    Pal, S.S.4    Laxmi, G.5    Gupta, M.6    Sahu, C.7    Vaitheeswaran, S.T.8
  • 127
    • 79956009860 scopus 로고    scopus 로고
    • Correlation of histological and clinical images to determine the diagnostic value of fluorescein angiography for studying retinal capillary detail
    • Mendis, K.R.; Balaratnasingam, C.; Yu, P.; Barry, C.J.; McAllister, I.L.; Cringle, S.J.; Yu, D.Y. Correlation of histological and clinical images to determine the diagnostic value of fluorescein angiography for studying retinal capillary detail. Invest. Ophthalmol. Vis. Sci. 2010, 51, 5864-5869.
    • (2010) Invest. Ophthalmol. Vis. Sci. , vol.51 , pp. 5864-5869
    • Mendis, K.R.1    Balaratnasingam, C.2    Yu, P.3    Barry, C.J.4    McAllister, I.L.5    Cringle, S.J.6    Yu, D.Y.7
  • 129
    • 77949894204 scopus 로고    scopus 로고
    • Noninvasive visualization and analysis of parafoveal capillaries in humans
    • Tam, J.; Martin, J.A.; Roorda, A. Noninvasive visualization and analysis of parafoveal capillaries in humans. Invest. Ophthalmol. Vis. Sci. 2010, 51, 1691-1698.
    • (2010) Invest. Ophthalmol. Vis. Sci. , vol.51 , pp. 1691-1698
    • Tam, J.1    Martin, J.A.2    Roorda, A.3
  • 135
    • 50049105042 scopus 로고    scopus 로고
    • In vivo measurement of erythrocyte velocity and retinal blood flow using adaptive optics scanning laser ophthalmoscopy
    • Zhong, Z.; Petrig, B.L.; Qi, X.; Burns, S. In vivo measurement of erythrocyte velocity and retinal blood flow using adaptive optics scanning laser ophthalmoscopy. Opt. Expr. 2008, 16, 12746-12755.
    • (2008) Opt. Expr. , vol.16 , pp. 12746-12755
    • Zhong, Z.1    Petrig, B.L.2    Qi, X.3    Burns, S.4
  • 138
    • 80051870166 scopus 로고    scopus 로고
    • Risk factors for four-year incidence and progression of age-related macular degeneration: The los angeles latino eye study
    • Los angeles latino eye study group
    • Choudhury, F.; Varma, R.; McKean-Cowdin, R.; Klein, R.; Azen, S.P.; Los angeles latino eye study group. Risk factors for four-year incidence and progression of age-related macular degeneration: The los angeles latino eye study. Amer. J. Ophthalmol. 2011, 152, 385-395.
    • (2011) Amer. J. Ophthalmol. , vol.152 , pp. 385-395
    • Choudhury, F.1    Varma, R.2    McKean-Cowdin, R.3    Klein, R.4    Azen, S.P.5
  • 141
    • 34748819371 scopus 로고    scopus 로고
    • Variation in complement factor 3 is associated with risk of age-related macular degeneration
    • Maller, J.B.; Fagerness, J.A.; Reynolds, R.C.; Neale, B.M.; Daly, M.J.; Seddon, J.M. Variation in complement factor 3 is associated with risk of age-related macular degeneration. Nat. Genet. 2007, 39, 1200-1201.
    • (2007) Nat. Genet. , vol.39 , pp. 1200-1201
    • Maller, J.B.1    Fagerness, J.A.2    Reynolds, R.C.3    Neale, B.M.4    Daly, M.J.5    Seddon, J.M.6
  • 142
    • 77957576743 scopus 로고    scopus 로고
    • Serum lipid biomarkers and hepatic lipase gene associations with age-related macular degeneration
    • Reynolds, R.; Rosner, B.; Seddon, J.M. Serum lipid biomarkers and hepatic lipase gene associations with age-related macular degeneration. Ophthalmology 2010, 117, 1989-1995.
    • (2010) Ophthalmology , vol.117 , pp. 1989-1995
    • Reynolds, R.1    Rosner, B.2    Seddon, J.M.3
  • 144
    • 77952120581 scopus 로고    scopus 로고
    • Genome-Wide association study of advanced age-related macular degeneration identifies a role of the hepatic lipase gene (LIPC)
    • Neale, B.M.; Fagerness, J.; Reynolds, R.; Sobrin, L.; Parker, M.; Raychaudhuri, S.; Tan, P.L.; Oh, E.C.; Merriam, J.E.; Souied, E. Genome-Wide association study of advanced age-related macular degeneration identifies a role of the hepatic lipase gene (LIPC). PNAS 2010, 20, 7395-7400.
    • (2010) PNAS , vol.20 , pp. 7395-7400
    • Neale, B.M.1    Fagerness, J.2    Reynolds, R.3    Sobrin, L.4    Parker, M.5    Raychaudhuri, S.6    Tan, P.L.7    Oh, E.C.8    Merriam, J.E.9    Souied, E.10
  • 147
    • 80052214839 scopus 로고    scopus 로고
    • Risk models for progression to advanced age-related macular degeneration using demographic, environmental, genetic, and ocular factors
    • Seddon, J.M.; Reynolds, R.; Yu, Y.; Daly, M.J.; Rosner, B. Risk models for progression to advanced age-related macular degeneration using demographic, environmental, genetic, and ocular factors. Ophthalmology 2011, 118, 2203-2211.
    • (2011) Ophthalmology , vol.118 , pp. 2203-2211
    • Seddon, J.M.1    Reynolds, R.2    Yu, Y.3    Daly, M.J.4    Rosner, B.5
  • 148
    • 59849104241 scopus 로고    scopus 로고
    • Molecular pathology of age-related macular degeneration
    • Ding, X.; Patel, M.; Chan, C.C. Molecular pathology of age-related macular degeneration. Prog. Retin. Eye Res. 2009, 28, 1-18.
    • (2009) Prog. Retin. Eye Res. , vol.28 , pp. 1-18
    • Ding, X.1    Patel, M.2    Chan, C.C.3
  • 149
    • 48449101416 scopus 로고    scopus 로고
    • The role of vascular endothelial growth factor and other endogenous interplayers in age-related macular degeneration
    • Grisanti, S.; Tatar, O. The role of vascular endothelial growth factor and other endogenous interplayers in age-related macular degeneration. Prog. Retin. Eye Res. 2008, 27, 372-390.
    • (2008) Prog. Retin. Eye Res. , vol.27 , pp. 372-390
    • Grisanti, S.1    Tatar, O.2
  • 150
    • 84863845318 scopus 로고    scopus 로고
    • Mechanisms of age-related macular degeneration
    • Ambati, J.; Fowler, B.J. Mechanisms of age-related macular degeneration. Neuron 2012, 12, 26-39.
    • (2012) Neuron , vol.12 , pp. 26-39
    • Ambati, J.1    Fowler, B.J.2
  • 154
    • 84866411715 scopus 로고    scopus 로고
    • In vivo imaging of photoreceptor disruption associated with age-related macular degeneration: A pilot study
    • Boretsky, A.; Khan, F.; Burnett, G.; Hammer, D.X.; Ferguson, R.D.; Van Kuijk, F.; Motamedi, M. In vivo imaging of photoreceptor disruption associated with age-related macular degeneration: A pilot study. Laser Surg. Med. 2012, 44, 603-610.
    • (2012) Laser Surg. Med. , vol.44 , pp. 603-610
    • Boretsky, A.1    Khan, F.2    Burnett, G.3    Hammer, D.X.4    Ferguson, R.D.5    Van Kuijk, F.6    Motamedi, M.7
  • 156
    • 33644655886 scopus 로고    scopus 로고
    • The number of people with glaucoma worldwide in 2010 and 2020
    • Quigley, H.A.; Broman, A.T. The number of people with glaucoma worldwide in 2010 and 2020. Br. J. Ophthalmol. 2006, 90, 262-167.
    • (2006) Br. J. Ophthalmol. , vol.90 , pp. 262-267
    • Quigley, H.A.1    Broman, A.T.2
  • 157
    • 79954621581 scopus 로고    scopus 로고
    • Glaucoma
    • Quigley, H.A. Glaucoma. Lancet 2011, 377, 1367-1377.
    • (2011) Lancet , vol.377 , pp. 1367-1377
    • Quigley, H.A.1
  • 161
    • 79952596593 scopus 로고    scopus 로고
    • Assessment of rates of structural change in glaucoma using imaging technologies
    • Mansouri, K.; Leite, M.T.; Medeiros, F.A.; Leung, C.K.; Weinreb, R.N. Assessment of rates of structural change in glaucoma using imaging technologies. Eye 2011, 25, 269-277.
    • (2011) Eye , vol.25 , pp. 269-277
    • Mansouri, K.1    Leite, M.T.2    Medeiros, F.A.3    Leung, C.K.4    Weinreb, R.N.5
  • 162
    • 84856950279 scopus 로고    scopus 로고
    • A survey and comparative study on the instruments for glaucoma detection
    • Lim, T.C.; Chattopadhyay, S.; Acharya, U.R. A survey and comparative study on the instruments for glaucoma detection. Med. Eng. Phys. 2012, 34, 129-139.
    • (2012) Med. Eng. Phys. , vol.34 , pp. 129-139
    • Lim, T.C.1    Chattopadhyay, S.2    Acharya, U.R.3
  • 163
    • 84858050337 scopus 로고    scopus 로고
    • High-Resolution imaging of the retinal nerve fiber layer in normal eyes using adaptive optics scanning laser ophthalmoscopy
    • Takayama, K.; Ooto, S.; Hangai, M.; Arakawa, N.; Oshima, S.; Shibata, N.; Hanebuchi, M.; Inoue, T.; Yoshimura N. High-Resolution imaging of the retinal nerve fiber layer in normal eyes using adaptive optics scanning laser ophthalmoscopy. PLoS ONE 2012, doi: 10.1371/journal.pone.0033158.
    • (2012) PLoS ONE
    • Takayama, K.1    Ooto, S.2    Hangai, M.3    Arakawa, N.4    Oshima, S.5    Shibata, N.6    Hanebuchi, M.7    Inoue, T.8    Yoshimura, N.9
  • 164
    • 84861099079 scopus 로고    scopus 로고
    • A clinical planning module for adaptive optics SLO imaging
    • Huang, G.; Qi, X.; Chui, T.Y.; Zhong, Z.; Burns, S.A. A clinical planning module for adaptive optics SLO imaging. Optom. Vis. Sci. 2012, 89, 593-601.
    • (2012) Optom. Vis. Sci. , vol.89 , pp. 593-601
    • Huang, G.1    Qi, X.2    Chui, T.Y.3    Zhong, Z.4    Burns, S.A.5
  • 165
    • 79961020531 scopus 로고    scopus 로고
    • Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics
    • Kocaoglu, O.P.; Cense, B.; Jonnal, R.S.; Wang, Q.; Lee, S.; Gao, W.; Miller, D.T. Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics. Vis. Res. 2011, 51, 1835-1844.
    • (2011) Vis. Res. , vol.51 , pp. 1835-1844
    • Kocaoglu, O.P.1    Cense, B.2    Jonnal, R.S.3    Wang, Q.4    Lee, S.5    Gao, W.6    Miller, D.T.7
  • 166
    • 84861093810 scopus 로고    scopus 로고
    • Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope
    • Merino, D.; Duncan, J.L.; Tiruveedhula, P.; Roorda, A. Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope. Biomed. Opt. Express 2011, 2, 2189-2201.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 2189-2201
    • Merino, D.1    Duncan, J.L.2    Tiruveedhula, P.3    Roorda, A.4
  • 167
    • 84855453497 scopus 로고    scopus 로고
    • Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging
    • Zawadzki, R.J.; Jones, S.M.; Pilli, S.; Balderas-Mata, S.; Kim, D.Y.; Olivier, S.S.; Werner, J.S. Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging. Biomed. Opt. Express 2011, 2, 1674-1686.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1674-1686
    • Zawadzki, R.J.1    Jones, S.M.2    Pilli, S.3    Balderas-Mata, S.4    Kim, D.Y.5    Olivier, S.S.6    Werner, J.S.7
  • 168
    • 79960634610 scopus 로고    scopus 로고
    • Characterization of single-file flow through human retinal parafoveal capillaries using an adaptive optics scanning laser ophthalmoscope
    • Tam, J.; Tiruveedhula, P.; Roorda, A. Characterization of single-file flow through human retinal parafoveal capillaries using an adaptive optics scanning laser ophthalmoscope. Biomed. Opt. Express 2011, 2, 781-793.
    • (2011) Biomed. Opt. Express , vol.2 , pp. 781-793
    • Tam, J.1    Tiruveedhula, P.2    Roorda, A.3
  • 169
    • 84867241267 scopus 로고    scopus 로고
    • The use of forward scatter to improve retinal vascular imaging with an adaptive optics scanning laser ophthalmoscope
    • Chui, T.Y.C.; Van Nasdale, D.A.; Burns, S.A. The use of forward scatter to improve retinal vascular imaging with an adaptive optics scanning laser ophthalmoscope. Biomed. Opt. Express 2012, 3, 2537-2549.
    • (2012) Biomed. Opt. Express , vol.3 , pp. 2537-2549
    • Chui, T.Y.C.1    Van Nasdale, D.A.2    Burns, S.A.3
  • 171
    • 78650616128 scopus 로고    scopus 로고
    • Spectral domain optical coherence tomography and adaptive optics: Imaging photoreceptor layer morphology to interpret preclinical phenotypes
    • Rha, J.; Dubis, A.M.; Wagner-Schuman, M.; Tait, D.M.; Godara, P.; Schroeder, B.; Stepien, K.; Carroll, J. Spectral domain optical coherence tomography and adaptive optics: imaging photoreceptor layer morphology to interpret preclinical phenotypes. Advan. Exp. Med. Biol. 2010, 664, 309-316.
    • (2010) Advan. Exp. Med. Biol. , vol.664 , pp. 309-316
    • Rha, J.1    Dubis, A.M.2    Wagner-Schuman, M.3    Tait, D.M.4    Godara, P.5    Schroeder, B.6    Stepien, K.7    Carroll, J.8
  • 172
    • 78649388464 scopus 로고    scopus 로고
    • In vivo high-resolution retinal imaging using adaptive optics
    • Seyedahmadi, B.J.; Vavvas, D. In vivo high-resolution retinal imaging using adaptive optics. Semin. Ophthalmol. 2010, 25, 186-191.
    • (2010) Semin. Ophthalmol. , vol.25 , pp. 186-191
    • Seyedahmadi, B.J.1    Vavvas, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.